UD should not possible without QE51N

Hi ALL,
Normally after the process order confirmation  UD is done directly from QA11...where it displays the message " Do you want to force inspection completion "...then by selecting "Yes" ...UD can be done....I want a scenario in which this wont be possible without QE51N...
Can anyone please throw light on this...?
Regards,
Ameya k.

Dear,
Please refer this link,
[Prevents the UD When the Result Recording is Incomplete|http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/20fbc091-ea3a-2b10-f0a3-877ffbf36436]
Regards,
R.Brahmankar

Similar Messages

  • Reg:Confirmation should not happen without issuing goods.

    Hi Friends.
    We have an issue regarding goods movement.
    I need to know, is there any setting can be made for the below issue.
    1. how to make settings that confirmation of production order or any goods movement( Of finished good) , should not be done untill and unless goods issue has been done for the order,.
    EX: After releasing the order , we have to issue goods for productionn. then only we can do confirmation.
    But we are facing the issue that without issuing the goods also, we are able to confirm. so i need to stop the confirmation or any goods movement which will happen without issuing the goods,,
    Waiting for your positive answers,,thank u in advace.

    Dear
    You can try the following user exit in your case : Enhancement - MBCF0002 /FM - EXIT_SAPMM07M_001/Include - ZXMBCU02
    Or T.code OPK4. Set termination of Order confirmation in case of wrong Goods movement.
    - Use User Status .T.code is BS02.
    Refer : GR restrict before Confirmation & Confirmation restrict before GI
    Regards
    JH

  • Control on GR, GR not possible without acknowledgement number in PO

    Hi All,
    While making goods receipts we want to have control wherein unless acknowledgement number is maintained in Purchase order against respective item, user should not be able to make goods receipt.
    Can anyone pls explain if this control can be done through any configuration setting or is there any userexit available.
    Regards,
    Ramya
    Edited by: Ramya V on Dec 24, 2008 7:48 AM
    Edited by: Ramya V on Dec 24, 2008 8:15 AM

    Hi,
    Try using the confirmation control key in PO.Also in Info record it is there and you can make it defaulted from there.
    Regards,
    Deepak.

  • Purchase order printout should not happen without release of PO

    I have made all the settings for PO release strategy and printout settings. But printout can be taken even before final release. I checked the settings and this printout should not happen before release. Please help me out.
    Thanks in advance.

    Hi,
    Thank ypu for your reply. PO was not released. Printout wa snot able to be taken in ME9F. But Printout can be taken using Print preview in Tcode ME22N. Can we avoid such printing using Print preview option.
    Thank you in advance

  • [SOLVED] Shutdown not possible without login manager

    When I login using slim as user, everything is fine.
    Automatic login without slim changes the rights of my user.
    When dbus is active as a daemon in rc.conf, wicd works fine (without dbus wicd would not work), but only xfce4 log-out is avaiblable. Xfce4-Shutdown and -restart is inactive.
    I'm not using a login manager, but mingetty, see
    https://wiki.archlinux.org/index.php/Start_X_at_Boot
    (used slim, at that stage I didn't have these kind of problems).
    according to the wiki
    https://wiki.archlinux.org/index.php/Au … al_console
    https://wiki.archlinux.org/index.php/Au … al_console
      /etc/inittab
    id:3:initdefault:
    rc::sysinit:/etc/rc.sysinit
    rs:S1:wait:/etc/rc.single
    rm:2345:wait:/etc/rc.multi
    rh:06:wait:/etc/rc.shutdown
    su:S:wait:/sbin/sulogin -p
    # -8 options fixes umlauts problem on login
    c1:2345:respawn:/sbin/mingetty --autologin hk tty1 linux
    c2:2345:respawn:/sbin/agetty -8 -s 38400 tty2 linux
    c3:2345:respawn:/sbin/agetty -8 -s 38400 tty3 linux
    c4:2345:respawn:/sbin/agetty -8 -s 38400 tty4 linux
    c5:2345:respawn:/sbin/agetty -8 -s 38400 tty5 linux
    c6:2345:respawn:/sbin/agetty -8 -s 38400 tty6 linux
    ca::ctrlaltdel:/sbin/shutdown -t3 -r now
    My ~/.bash_profile
    if [[ -z $DISPLAY && $(tty) = /dev/tty1 ]]; then
    #startx &> /dev/null &
    exec ck-launch-session startxfce4
    #xinit /usr/bin/xfce4-session
    fi
    I have tried different commands in my ~.xinitrc, but no change of behaviour
    1. exec ck-launch-session dbus-launch startxfce4 (I read somewhere that ck must be started before dbus-launch)
    2. exec ck-launch-session startxfce4
    When dbus is inactive in the rc.conf daemon's session, wicd does not work, but I can shut down the computer.
    Last edited by mumpf (2012-02-13 18:27:21)

    it works now with the help of a debian thread, unfortunately in German
    http://debianforum.de/forum/viewtopic.php?f=2&t=131087
    three additional files in /etc/polkit-1/localauthority/50-local have to set up (exactly the way they are in the thread):
    etc/polkit-1/localauthority/50-local.d/org.freedesktop.consolekit.pkla
    etc/polkit-1/localauthority/50-local.d/org.freedesktop.udisks.pkla
    etc/polkit-1/localauthority/50-local.d/org.freedesktop.upower.pkla
    For Archlinux the group powerdev has to be replaced by power and users by storage
    in sudoers /usr/lib/xfce4/session/xfsm-shutdown-helper has to be removed.
    After a restart all should work (mount and restart works on my installation now).

  • Working with canon 6d CR2 files not possible without converting to DNG?

    I have a brand-new down on 60 camera which generates CO2 files. Unfortunately I have not been able to edit any of my photos using Adobe camera raw or bridge or Photoshop without converting to DND files. Do you and you files are larger than the CR to file sizes and therefore I don't like them. Is there anyway for me to work directly on my Cr2  files like I did on my NEF files when I had the nikon? Yes my Photoshop is up-to-date.

    What version of Photoshop are you using, and what version of Camera Raw plug-in (ACR) are you using?
    If your camera is a 6D then you need Photoshop CS6 and ACR 7.3 or newer to open the CR2 files.
    If your camera is a 60D then you need Photoshop CS5 and ACR 6.2 or newer to open the CR2 files.

  • Synchronization of calendar is not possible without wifi

    Hi!
    I just updated my MacBook Pro to Mountain Lion and I can now sync my Mac and iPhone via iCloud and it works fine at home.
    My iPhone is also my work phone and at work I have a PC, where I also have installed iCloud.
    The problem is that we do not have WiFi at work, so I have to use the cable if I want to update my calendar on the phone.
    When the phone is set up for iCloud, I can not manually control when I connect via iTunes, if I want to update the calendar, since it is "programmed" to be updated automatically via iCloud.
    Can I turn off this or iCloud on the phone so I can sync via cable or am I forced to "uninstall" iCold on the phone at work and reinstall when I get home?
    PS: iPhons is not a "safety approved" phone in our company, so I'm not allowed to connect directly via the company server.

    Okay time for an up-date.
    I found the solution myself. In you go into setting and into icloud settings, you can turn off automatic sync.
    This allows me to sync via cabel at work and at the same time, allows me to sync. photos, sms chat ect. via iCloud at home.

  • Scroll Vertically should not possible in Table Control

    Hi,
    In Screen Painter (SE51), we created a Table control program. It's working fine but we want that User cann't able to scroll Vertically.
    In Table Control Properties, there is a option for Fix Column. From here, we can fix the columns but we want to Fix the Rows.
    Please guide...

    Hi,
    In the PBO of the subscreen. Assign some value to the tablecontrol-lines field as below;
    Describe table itab_for_tablecontrol lines tablecontrol-lines.
    OR
    Tablecontrol_lines = 10.
    Regards,
    Karthik D

  • Production order should not be saved without entering Batch in it

    Hello PP Gurus
    In my PP scenario Batch mangement is active for finish material I want to make Batch entry mandetory for Production order Order should not saved without Batch in it
    With the help of ABAP I have made Batch field Mandetory but still order is saving as this batch field is coming in third tab page
    is there any configuration in batch management (i have checked in order type ) to make batch entry mandetory
    Please give your kind suggestion
    With Regards
    Babel S.G.

    Hi,
    Your post is very strange to me. Is it possible to confirm a production order with a batch-managed (header) material w/o entering a batch number? It would wonder in standard SAP...
    Have you activated batch management for your material? And at which level (plant, material, client)?
    Or are you speaking about entering a batch no. for your FG in the PrdOrd itself (in CO01 when you create) - it would be a total different issue...
    Please give feedback.
    Csaba

  • HT1386 Why is not possible to sync just content like musice ONLY, when I have no time to wait on whole proces of synchronization, there SHOULD be a way to sync JUST MUSIC and nothing else, I dont wanna wait 10minutes to have 3 songs I want to have in my i

    Dear Apple, why is not possible in the year 2014...sync to my iPhone just content I want to separety, without the whole sync procedur(backinup,syncing whole purchased things and stuff like that) When I want to have in my phone for example just 3 new songs ..I dont wanna wait 10minutes because of whole synchronization!!! I want add to my iPhone just these 3 songs thats it! Would be perfect, If you will make possible to sync just parts like MUSIC, Apps, Fotos, separetly and not alltime together...it s****!

    Ok.
    I have Windows OS and iTunes for PC, but the problem is not in my PC, but in synchronization. Your synchronization take minute or two, you have thunderbolt lightning cable??? If is it by you really so quick than ok but by me is it with sync really slow and I have still powerhouse notebook.
    I dont know how is it possible that your sync is so quick, but my iPhone starts transfering purchased aplications and all content to the PC, instead of downloading it PC itself without iPhone from iStore.  So there is what happend when I am conecting my iPhone.
    When it find my iPhone on the first try, it starts makeing backup, than transfering photos, aplication, some info from Safari and to the end also the MUSIC...this should be improved by Apple and it should be able to sync just MUSIC section and not whole system, when I changed just something in MUSIC section(like adding new CD..)
    So it does on PC whole resync Maybe is it somewhere in options, but where? I really want sync sometimes just MUSIC or just Apps and nothing else(like Photos, Bookmarks...)
    I am sorry for that angry tone, but I am really stresedby this 20minutes sync or 10 miutes...just becouse of adding 1-2 songs, this is by competition phones quicklier :/ !
    Message was edited by: Tenotitlan

  • Is it not possible to give the select single field without an into clause

    Hi,
    i have to check whether my input value( only one filed) is available in the table.
    for eg i need to check whether company code is available in the table t001.
    then i will give .
    data lv_bukrs type t001-bukrs.
    lv_bukrs = 1010.
    select single bukrs from t001 where bukrs = lv_bukrs.
    here its asking for me to give a vaible to store the bukrs that is
    select single bukrs into dummyvalue from t001 where bukrs = lv_bukrs.
    Is it not possible to give the select single fieldname without an into clause

    Its Possible by declaring the tables statement
    <b>tables : AFKO.
    select single * from AFKO where <condition>.</b>
    If SINGLE is specified, the resulting set has a single line. If the remaining additions to the SELECT command select more than one line from the database, the first line that is found is entered into the resulting set. The data objects specified after INTO may not be internal tables, and the APPENDING addition may not be used. The addition ORDER BY can also not be used.
    An exclusive lock can be set for this line using the FOR UPDATE addition when a single line is being read with SINGLE. The SELECT command is used in this case only if all primary key fields in logical expressions linked by AND are checked to make sure they are the same in the WHERE condition. Otherwise, the resulting set is empty and sy-subrc is set to 8. If the lock causes a deadlock, an exception occurs. If the FOR UPDATE addition is used, the SELECT command circumvents SAP buffering.
    Notes
    When SINGLE is being specified, the lines to be read should be clearly specified in the WHERE condition, for the sake of efficiency. When the data is read from a database table, the system does this by specifying comparison values for the primary key.
    If accessing tables for which SAP buffering is planned for single records, the SAP buffer is bypassed if the addition SINGLE is not specified. This behavior depends on the current implementation of the database interface and may change in future releases. In particular, it should not be used to bypass the SAP buffer. You should use the explicit addition BYPASSING BUFFER for this instead.
    The addition SINLGE is not permitted in a subquery.
    Regards
    - Gopi

  • It should be possible to close a thread without saying it's answered.

    It should be possible to close a thread without saying it's answered.
    Maybe closed - resolved or closed - not resolved.
    Edited by: Mike Angelastro on Jan 29, 2010 6:43 AM

    Mark it answered may not mean your question is answered.  If you do not satisfy all replies, you simply do not assign any points.  Everyone will know it is not answered.  You may post the last message as No satisfied answer.
    Thanks,
    Gordon

  • Without Purchase Requistion , Purchase Order should not be raised

    Dear All,
      Can any one tell me , How can i do the setting without purchase requisition , purchase order should not be raised.
    Regards
    Suresh

    Hi,
    1. Transcation code : OMET - Function authorization
    in that, there is one check box called REF TO PURCHASE REQUISTION under the section of possible reference object (2nd from top). Activate this check box.
    Assign this Function authorization key to the user profile.
    Now onwards, this specific user cann't create PO with out PR. 
    PR is mandatory for the PO creation for this user only. But other users can create PO, with out PR also.
    This is user level control
    2. Transcation: OMEC
    Select your document type and   note down some where filed selection key which is maintained for your document type.
    Transcation code :OMF4
    Navigation path : Spro-Materials Management-Purchasing-Purchase Order-Define Screen Layout at Document Level
    Select field selection key, which is identified in the first step and click on the details icon.
    Click on the "Reference data, item"
    set Purchase requisition as required (mandatory) entry.
    Now onwards, you cann't create PO with out PR number.
    This control is applicable for all the users. But for your document type only, which is used in the first step.
    For what are the document types used this field selection key, you can't create PO with out PR number.
    For other document types you can create PR with out PR number also.
    Regards
    KRK

  • Without result recording closing system should not allow for usage decesion

    Hi
    without result recording closing system should not allow for usage decision.I think it is possible through user status. Please tell the procedure .
    Thanks and regards,
    vairavan

    Dear vairavan,
    You can check for the authorisation object.I can't remember that authoriation object right now.But surely you can restrict that with authorisation object.
    Anyone knows the authoristaion object.
    Regards,
    Sunil Patil

  • Not possible to scroll the menu without lagging - Set Up a Repair service is not working

    Hi,
    It is not possible to scroll the menu without lagging.
    The latest version has been restored but nothing.
    I think the touch screen is having some problems.
    I wanted to use the Set Up a Repair / Send In for service but it seems that the application form doesn't working.
    As soon as push the Continue button, nothing happens.
    Is there anybody from Apple who can check this issue please?
    Thank You.
    Anmary

    Restoring a phone from a backup will put the device back to the state it was when the backup took place, i.e. all info that you had on that phone before using the backup will be gone.
    You could try to restore the phone, which will back up the actual data on the phone, including the passcode, and use this backup to set up a new phone with. The passcode will still be the same, because it is  part of the backup.
    More info here, iPhone and iPod touch: Wrong passcode results in red disabled screen
    Not being able to fill in the passcode is not much different from forgetting it.
    If you cannot remember the passcode, you will need to restore your device using the computer with which you last synced it. This allows you to reset your passcode and resync the data from the device (or restore from a backup). If you restore on a different computer that was never synced with the device, you will be able to unlock the device for use and remove the passcode, but your data will not be present. Refer to Updating and restoring iPhone, iPad and iPod touch software.
    Also have a look at this one: iTunes: About iOS backups

Maybe you are looking for