Unable to Deploy Applications:  "process is not defined in the descriptor"

All
I'm having a fairly serious issue here trying to take an LCA from one environment and get it in another environment.  Both the source and destination environments are LCES 2.5 (LCES 2 with SP2).  I have roughly 6 applications and there are some far dependencies (one application referencing an asset of another application) therein.  I've taken an LCA of all these applicaitons from the source environment and the LCA imports just fine in the destination environment but I am unable to deploy any of the applications that have far dependencies.  The error I consistently get when I attempt to deploy any application that has a far dependency is:
[Some process name].process is not defined in the descriptor.
I have tried all of the following:
1) Taking 1 LCA of all applications together
2) Taking multiple LCAs where each LCA contains only one application
3) Taking multiple LCAs where each LCA includes an application as well as all far dependencies for that application
Regardless of what I try, they won't deploy.  I can import the LCA and I can get the applications in Workbench and play around with them but they simply won't deploy.  I've also attempted to manually fix all depencies within the processes themselves but that doesn't work either.
Any help would be appreciated.

Just wanted to follow up on the solution to my issue.
It appears the issue centers around circular far dependencies.  In general, it seems LiveCycle chokes when two applications each reference one another.  Note that I'm not talkinng about true circular referencing here wherein one process within application A references a process in application B while that same process refers back to the original process in application A.  In fact, although I haven't tested recently, I believe LiveCycle may actually catch this kind of issue.  The circular far dependencies I'm talking about is simply where a process in application A (call it a1) references a process in application B (call it b1) while a process in application B (call it b2) references a process in applicatoin A (call it a2).  Apparently this kind of circular referencing causes the deployment of said applications to choke.
The fix was tedious as I had to manually delete all of the far dependencies from both application, deploy those two applications to get them into the runtime, and then implement those dependencies again.
Going forward it seems like a best practice to only ever have 1 direction for dependencies for any application.

Similar Messages

  • .process is not defined in the descriptor

    I am currently working on a system that is base ES2.
    I encounter this error in Workbench when deploying a copied application.
    I also get the error when trying to import archives on the server.
    It usually points to a SubProcess.
    Can anyone tell me if this error is fixed as SP1, or SP2?
    - or - is there any other way around this issue?
    I have looked at the release notes, but do not see a clear match on this error.
    Thanks!
    Mark

    Just wanted to follow up on the solution to my issue.
    It appears the issue centers around circular far dependencies.  In general, it seems LiveCycle chokes when two applications each reference one another.  Note that I'm not talkinng about true circular referencing here wherein one process within application A references a process in application B while that same process refers back to the original process in application A.  In fact, although I haven't tested recently, I believe LiveCycle may actually catch this kind of issue.  The circular far dependencies I'm talking about is simply where a process in application A (call it a1) references a process in application B (call it b1) while a process in application B (call it b2) references a process in applicatoin A (call it a2).  Apparently this kind of circular referencing causes the deployment of said applications to choke.
    The fix was tedious as I had to manually delete all of the far dependencies from both application, deploy those two applications to get them into the runtime, and then implement those dependencies again.
    Going forward it seems like a best practice to only ever have 1 direction for dependencies for any application.

  • Correlation set was not defined in the process

    Hi All,
    I deplyoed a synchronous CustomerProviderABCS on SAO 11g server.
    This process is invoking the Adapter service(mediator) which internally calls the SAP Adapter.
    I didn't define any correaltion sets and I am not using pick activity.
    After deploying the Provider I am getting the follwing issue:
    java.lang.Exception: oracle.sysman.emSDK.webservices.wsdlapi.SoapTestException: Correlation definition not registered. The correlation set definition for operation SyncCustomerParty, process default/SyncCustomerPartySAPProvABCSImpl!2.2*soa_33303a8b-c115-4a93-b338-094e4a4c4078/SyncCustomerPartySAPProvABCSImplProcess, is not registered with the server. The correlation set was not defined in the process. Redeploy the process to the container. at oracle.sysman.emas.model.wsmgt.WSTestModel.invokeOperation(WSTestModel.java:575)
    I tried by redeploying the process multiple times.
    any workaround please........
    Thanks in adavance.
    Edited by: user6402392 on Jan 12, 2011 10:26 PM

    I don't know what happened to my server but now I am getting same issue with all my BPEL processes and earlier same process were working fine and I tired to use SOA-DIRECT and then this issue came but I removed it but still same issue and then I created new simple synch process but same issue is coming ......looks like need to change some config or some setting somewhere....please help if anybody have any idea?
    Thanks a lot in advance...
    Regards,
    Bijendra

  • Method 'PROCESS' is not defined for object type 'BUS2081'

    Hi All,
    I am using a workflow for incoming invoice approval using WS20001004. I prepared one version for this. The standard business methos bus2081 i delegated to zbus2081. Here i placed one decision step for reject or approve. In the same task in inbox i can see the document i can see as attachment. Now the issue is after seeing the attachment when i click on task in  my inbox it status is changed to red and i can  not process it further.In log i can see the error like Method 'PROCESS' is not defined for object type 'BUS2081'. This method i do not have in standard or in delegated one. I was struck here. Pleas help in this.
    Regards,
    Madhu.

    Hi,
    "Here i placed one decision step for reject or approve." if your workitem is based on standard user decision step type of workflow, then the business object in underlying task should be 'DECISION' and method should be 'PROCESS'. I think in the task you have put your custom business object instead of business object 'DECISION'. This could be the reason you are facing error.
    Regards,
    Ibrahim

  • TS1702 Upon switching on my ipad, I'm getting the caption "Unable to Download Application "*Solitaire" could not be downloaded at this time." Further, I'm getting 2 options - Done & Retry, both of which are not responding. The ipad is in the hanged situat

    Upon switching on my ipad, I'm getting the caption "Unable to Download Application "*Solitaire" could not be downloaded at this time." Further, I'm getting 2 options - Done & Retry, both of which are not responding. The ipad is in the hanged situation for all practical purposes. How do I get out of this situation?

    Try a reset:
    1. Hold the Sleep and Home button down (together)
    2. For about 10 seconds
    3. Until you see the Apple logo (very important)
    4. Ignore the red slider

  • ERROR "Application (vod) is not defined." when creating new vhosts

    I'm testing FMS 4.5 using the developer edition before upgrading our FMS 3.5 servers to 4.5 but for some reason creating new vhosts doesn't seem to work.
    I'm following the exact same steps I would take using v3.5 but 4.5 gives this error:
    Sep 29 03:34:24 eventstreaming Javascript[31564]: Connection rejected by server. Reason : [ Server.Reject ] : (_defaultRoot_, vhost1.somedomain.com) : Application (vod) is not defined.
    Here are the steps I've taken:
    Made a copy of folder   _defaultVHost_/   named   vhost1.somedomain.com/     ( inside conf/_defaultRoot_ )
    Made an exact copy of the default FMS4.5 applications/  folder  at  /home/vhost1/public_html/applications
    Edited  vhost1.somedomain.com/vhost.xml and changed
    <AppsDir>${VHOST.APPSDIR}</AppsDir>
    TO
    <AppsDir>/home/vhost1/public_html/applications</AppsDir>
    Edited /home/vhost1/public_html/applications/vod/Application.xml and changed the path to the media files. i.e.
    <Streams>/;${VOD_COMMON_DIR}</Streams>
    <Streams>/;${VOD_DIR}</Streams>
    TO
    <Streams>/;${VOD_COMMON_DIR}</Streams>
    <Streams>/;/home/vhost1/public_html/applications/vod/media</Streams>
    Restarted FMS
    The VOD application in the default FMS applications folder works fine but the one for the new vhost doesn't. When I try to connect to rtmp://vhost1.somedomain.com/vod/media/sample.flv I get the error
    Sep 29 03:34:24 eventstreaming Javascript[31564]: Connection rejected by server. Reason : [ Server.Reject ] : (_defaultRoot_, vhost1.somedomain.com) : Application (vod) is not defined.
    No other errors are reported in the logs when I strart FMS. Why is the VOD application not working for new vhosts? Either I'm missing something obvious or the developer edition is restricted to one vhost perhaps?

    I tried same scenario at my end and its working for me. Probably there is something wrong which you are doing. For developer edition you should be able to have 3 vhosts.
    Why are you using URI like this: rtmp://vhost1.somedomain.com/vod/media/sample.flv --> it should be rtmp://vhost1.somedomain.com/vod/sample.flv

  • SFLIGHT is NOT defined for the current logical database.

    I have just started learning ABAP and bought an ABAP Objects book by Horst Keller. I have installed 4.6d mini sap and SAP GUI 6.4 on win XP Prof. I executed S_FLIGHT_MODEL_DATA_GENERATOR to load DB tables.
    (1). When I tried to check a sample program, I get an error message SFLIGHT is not defined for the current logical database.
    Here is the partial code:
    REPORT zbcb01f1 .
    TABLES: sflight, sbook.
    DATA: BEGIN OF sr OCCURS 100,
          carrid LIKE sbook-carrid,
          connid LIKE sbook-connid,
          fldate LIKE sbook-fldate,
          bookid LIKE sbook-bookid,
          order_date LIKE sbook-order_date,
          loccuram LIKE sbook-loccuram,
          END OF sr.
    GET sflight.   <---- Error is pointed here
    (2). I am also not getting Graphical Screen Painter when selecting Layout for a screen. Instead, I am getting alphanumeric editor.
    Someone please help me.  
    Raizak.

    Hi Raizak,
    the easiest way is to go to service.sap.com/notes and enter the note number. For this time I've copied the 2 notes below.
    Best regards,
    Christian
    Symptom
    The Graphical Layout Editor of the Screen Painter either does not start or terminates.Error message 37527 is displayed in the session in which the call was made (Graphical Layout Editor not available.
    Additional key words
    () EUNOTE, EUSCREENPAINTER, 37 527
    Cause and prerequisites
    This note comprises all the common causes for error message 37527 and provides you with information on how to systematically trouble shoot the problem.
    1. Windows32 or UNIX/motif?
    As of Release 4.6B there is only the program version for 32bit Windows (NT, 95, 98, 2000 ff.).Up to Release 4.6A there was also a version for UNIX/Motif.All of the more current notes (with the exception of Note 45490) refer only to the Windows version.
    2. Termination at the start or during use?
    The following diagnostic steps refer to the causes of the errors which prevent the Graphical Layout Editor from starting. However, there are also known error causes, which result in the program terminating when the application is being used and which also produce the 37527 error message. This affects -
    Rel.4.6C/D: Termination when attempting to read texts in the logon language -> Note 375494
    Crash after transferring program and dictionary fields. Termination after transferring program and dictionary fields -> Note 189245
    Release 3.1I: Termination after inputting field text -> Note 113318
    3. Is the SAPGUI installation correct?
    The Graphical Layout Editor is automatically installed during the standard installation of the SAPGUI.If you chose a non-standard installation, then you should have explicitely selected its installation (component "Development Tools - Graphical Screen Painter").
    The program executable is called gneux.exe.During the SAPGUI installation it is placed in the same directory as the SAPGUI programms (for example, front.exe) (usually C:\Program Files\SAPpc\sapgui). The following belong to the program:
    - An additonal executable gnetx.exe (RFC starter program)
    - the DLL eumfcdll.dll
    - various eusp* data files (that is, the names all begin with eusp.)
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.
    4. System link defined and okay?
    The Graphical Layout Editor is a separate program which is started by the Screen Painter Transaction (SE51) on the Frontend machine.
    Up to Release 3.0F, the programs communicated with each other via the graphics log of the SAPGUIs (gmux).The definition of the environment variable SAPGRAPH may be the cause for the program not being being found where it is.
    As of Release 3.1 G, the programs use a separate RFC link which is set up in addition to the SAPGUI's RFC link.Missing or incorrect definitions of the RFC destination EU_SCRP_WN32 or problems with the creation of the RFC link are the most frequent causes for error message 37527 being displayed.Below you can find the correct settings for the RFC destination EU_SCRP_WN32 (under "Solution").Note 101971 lists all the possible causes for problems with the RFC link set-up. Attention:The Graphical Layout Editor may not be operated through a firewall (for example between the SAP and the customer system) because this does not allow an additional RFC connection in addition to the SAPGUI.
    Solution
    ad 1 UNIX/Motif
    Note 45490 describes possible errors resulting from an incorrect program installation under UNIX/Motif (up to Release 4.6A).
    ad 2 Termination when using
    The above-mentioned notes may contain options for solving individual problems.However, you usually have to replace the program with an corrected version.You can do this either by downloading a patch from sapservX or by installing a more current SAPGUI.The patch is mentioned in the respective note.
    ad 3 Installation
    You either need to reinstall the SAPGUI or manually copy the missing file into the SAPGUI directory.In both cases you should make sure beforehand that a Graphical Layout Editor is no longer running.To do this you can either remove all processes gneux.exe from the process list by using a tool such as Task Manager (on WindowsNT) or exit the Graphical Layout Editor from the Screen Painter Transaction menu via Edit -> Cancel Graphical Screen Painter). Attention:For each session or system an individial Layout Editor process may exist so that, if need be, several processes should be cancelled.
    ad 4 System link
    Up to Release 3.0F:you can either delete the environment variable SAPGRAPH or copy all the files of the Graphical Layout Editor into the directory which is specified by SAPGRAPH.
    As of Release 3.1G:you can use Transaction SM59 to check the RFC destination EU_SCRP_WN32 (expand the TCP/IP connections, select destination EU_SCRP_WN32).If the destination is missing, then you should create it with the following settings:
    - Connection type "T" (start of an external program via ...)
    - Activation type "Start"
    - Start on "Front-end workstation"
    - Front-end workstation program "gnetx.exe" (caution! NOT gneux.exe)
    - Description (optional) "Graph. Screen Painter (Windows32)
      Start Program gneux.exe using the gnetx.exe starter program."
    If you want to start the program from a different directory than the SAPGUI standard directory, then replace the default value under Frontend work station by the complete path name for program gnetx.exe.Transaction SM59 also allows you to check the RFC connection via the pushbutton "Test connection").In this case the system attempts to localize and start the program gnetx.exe.If there are errors, a message is displayed regarding the possible causes (for example, gateway problem, timeout problem or the like).Note 101971 provides a detailed explanation of the problems involved with an RFC connection set-up.As the Graphical Screen Painter requires a functional RFC connection as of Release 3.1G, contact the System Administrator or create an message on the topic Middleware (BC-MID-RFC) if you encounter RFC problems.
    If the program gnetx.exe can be found and started, the banner dialog box with logo, release data and version number is displayed briefly.As the Layout Editor itself is not started, the error cause must be in the installation of the Layout Editor program gneux.exe if the connection test was successful.
    Release 4.5A to 4.6B: Use with Releases <3.1G>.
    The Graphical Layout Editor is downward-compatible as regards the system connection, that is, an RFC-based Layout Editor for example from Release 4.6C can also be used on a non-RFC-based Screen Painter, for example of Release 3.0F.However, the releases mentioned above have a program error which causes a crash due to memory violation in the start phase of the program.Note 197328 describes the solution by installation of the corrected program version.
    Important: Trace file dev_euspNNN!
    If none of the diagnosis steps leads to the cause of the error and to the solution of the problem via the corresponding note, then you should add the contents of the trace files dev_euspNNN (NNN = process number) to the message for SAP, if possible.You can find this file in the current directory of the SAP System, for example under Windows NT in C:\Winnt\Profiles\<user>\SAPworkdir.If several such trace files can be found there, make sure that you use the file which matches the termination time with respect to date and time of creation.In most cases the ERROR message in the last lines of this trace file provides an important note on the cause of the error.
    Source code corrections
    Symptom
    The graphic layout editor of the Screen Painter cannot be started (RFC version).
    Other terms
    () EUNOTE, EUSCREENPAINTER
    Reason and Prerequisites
    This is generally caused by the fact that the RFC connection between the frontend graphics layout editor and the calling screen painter program at the backend cannot be set up.
    Possibility 1: Route permission denied
    In the trace file dev_eusp<Process Id> of the graphics layout editor you find the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR route permission denied (<Front-Id> to <BackId>,<Service>)".
    If there is a firewall between frontend computer and application
    server, you need to decide whether the port for the RFC of the graphical layout editor can be released here (see Solution 1 below).
    In case no firewall exists between the frontend computer and the application server, in its route permission table, the SAProuter contains either no entry for the frontend computer, on which the graphics layout editor is started, or the entry says that the link is saved by a password.Since the connection is denied, the graphics editor processes exits again, and the screen painter switches to the alphanumeric layout editor.
    Possibility 2: Service 'sapgw<ServiceId>' unknown
    In the trace file dev_eusp<ProzessId> of the graphics layout editor you have the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR service 'sapgw<ServiceId>' unknown".
    The service sapgw<ServiceId> (for example, sapgw00) is not known on one of the computers participating in the RFC communication because the corresponding entry is missing in its service file. The affected computer can be the frontend computer or the gateway computer.
    Possibility 3: The system parameter gw/cpic_timeout value is too low
    This system parameter determines how many seconds the gateway is waiting for the RFC connection to be set up.In case of a high network load, the default value of 20 seconds is too small with the result that the connection cannot be created on time.Here the graphics layout editor process also exits with the trace file entry "ERROR in RFCMgr_accept: not accepted".
    Possibility 4: System parameter abap/no_sapgui_rfc set
    The profile parameter abap/no_sapgui_rfc of the system is set (that is, it has a value not equal to space or 0).This prevents the program of the graphics layout editor from being started with RFC at the frontend.
    Possibility 5: Unnecessary authorization check
    The error message "No RFC authorization for user xxxxxx" is generated although the check of the RFC authorization was deactivated by profile parameter auth/rfc_authority_check (value = space or 0). The problem is caused by a program error, that ignores the value of the profile parameter let during the call of the RFC authorization check (see Note 93254). This error can occur as of Release 4.5.
    Solution
    ad 1) If a Firewall is installed between frontend computer and the application server, you need to decide whether the port for the RFC link of the graphical layout editor shall be released in the firewall. This is port 33nn, where nn is the 2-digit system number of the SAP application server. As of Release 3.1G, the graphical layout editor needs an RFC link for communication with the application server in addition to the already existing linkof the SAP GUIs. Such a second link is not allowed by the firewall in general because it would contradict the security concept (password protection, logging of the connection).
    If no firewall exists, you should check whether the frontend computer can be added to the route permission table or whether the password option can be removed from out of the available entry.
    For details refer to chapter 4.4 of the attached Note 30289.
    ad 2) Include service sapgw<ServiceId> in the service file.
    Refer to Note 52959 for details.
    ad 3) Increase value for system parameter gw/cpic_timeout. 60 seconds should be sufficent as a timeout limit.
    ad 4) Set the system parameter abap/no_sapgui_rfc to space or 0
    Start the application server so that the new parameter value comes into effect.
    ad 5) Import the Support Package specified in the attachment for the release in question or implement the advance correction in the source code as described in the attached correction instructions.
    As a workaround, assign RFC authorizations as described in Note 93254.

  • While starting the weblogic server i am getting the agent is not defined in the topology for master repository

    [INFO] MBeanExporter - Unregistering JMX-exposed beans on shutdown
    <Nov 8, 2013 2:53:54 PM IST> <Error> <Deployer> <BEA-149231> <Unable to set the activation state to true for the application 'oraclediagent'.
    weblogic.application.ModuleException: [HTTP:101216]Servlet: "AgentServlet" faile
    d to preload on startup in Web application: "oraclediagent".
    ODI-1405: Agent OracleDIAgent start failure: the agent is not defined in the top
    ology for master repository.
    at oracle.odi.runtime.agent.servlet.AgentServlet$1.doAction(AgentServlet
    .java:828)
    at oracle.odi.core.persistence.dwgobject.DwgObjectTemplate.execute(DwgOb
    jectTemplate.java:186)
    at oracle.odi.runtime.agent.servlet.AgentServlet.getSnpAgentForAgentInst
    ance(AgentServlet.java:820)

    Most of the time this error is coming from a wrong psservername parameter definition in configuration.properties of your Webserver. Be sure you can ping the servername or IP address defined, and the port is the Jolt port of the AppServer domain.
    Please, show us what's the value. And also your PTools, Weblogic, Tuxedo version and OS used.
    Nicolas.

  • Third-party not defined in the case of vendor with plant assignment ?

    We use a Third-Party Vendor to direct-ship some products directly to our Customers.
    When transfers third party order form's PR STO PO, prompts the following information
    Third-party not defined in the case of vendor with plant assignment
    Message no. 06769
    Diagnosis
    You are entering a purchase transaction involving a vendor to whom a plant has been assigned. Normally, this will involve the transfer of materials from one plant to another.
    This process necessitates a delivery and a billing document in the SD system. The PO appears directly in the delivery due list of the issuing plant (vendor) and therefore does not need to be transmitted.
    However, an item with the procurement form "third-party" (triangular business deal) cannot appear in the delivery due list.
    Procedure
    An item with the procurement form "third-party" can only be ordered from vendors without a plant assignment.
    how should solve?
    Many thanks,  Adny.
    Edited by: Andy Yao on Feb 8, 2010 3:58 AM

    Hi Andy
    Why u doing stock transfer order,in third party sales there is no stock transfer
    Follow below procees for third party sales( Vendor ship materials directly to customer)
    Create Sales order(Use item category TAS) >>> Purachase requisition(Automatically from order) >>> Purchase order >>> Vendor Invoice Verification >>> Invoice to customer
    Kapil

  • View BT26H_APPT/ApptDetails is not defined in the run time repository.

    Hi,
    I am getting this error when i component work bench.view BT26H_APPT/ApptDetails is not defined in the run time repository that was loaded. can i manually load in run time repository or how can i approach this issue.
    rose.

    Hi Rose,
    While enhancing any component using an enhancement set you can give any name for bsp application under customer namespace ( like z, y) but usually when we create a new application we just put the z or y infront of the component name and create it  for example if you want to enhance bp_head_search then usually people create a new bsp appl with name zbp_head_search because it will help in finding it in se80 to figure out the component anyway you can give any name if you want.
    For each component you need to create a new bsp appl.
    You should use one enhancement set per client, you can use sm30 and view BSPWDV_EHSET_ASG  to define your enhancement set for each client.
    So to enhance all the component in same client you should use same enhancement set for that client.
    I think that would be useful, let me know if you have any other doubts.
    Thanks,
    Shobhit

  • InfoSource 80FIAR_O03 is not defined in the source system

    Hello,
    I am facing one issue while running process chain in Test client.
    Isssue: 0FI_AR_4 process chain loading to ODS successfull. the next step in process chain is further update. data is goint to cube. error getting u201CInfoSource 80FIAR_O03 is not defined in the source system.u201D  i have replicated the DS and activated 3-4 times also ran progam also. but still getting same error message. i deleted data from cube. In productio its running fine.
    currently client is updating ECC 6.0 system
    what could be root cause?
    Thanks in advance
    CPY

    Hi,
    Can you please check this thread :
    Re: InfoSource 80FIAR_O03 is not defined in the source system
    Cheers,
    Tanish.

  • Extraction Problem - DataSource is not defined in the source system

    Hi,
    I am loading transaction data into sales cubes, while loading in process chain it shows "No Data"
    so when i go in rsa3 extration for checking availibilty of data.
    The following message shows,
    DataSource 2LIS_12_VCHDR is not defined in the source system.
    In LBWE first it was shown Inactive then i make it active.
    So, what is the procedure to defined this data source to the source system.
    Thanks & Reagards,
    SD.

    Hi All,
    Thanks for ur reply.
    But i can not found the datasource in RSA5, can anyone explain how to find the datasource in RSA5?
    Datasource name : 2LIS_12_VCHDR , Cube Name : 0SD_C03
    and how to activate in RSA5 ? & after activation how can migrate the same datasource in r3 side by replication?
    Also the procedure to fill up the setup tables and then do the loading from r3side by thorugh infopackage...
    Thanks & Regards,
    SD

  • Deployment Rule Sets do not properly launch the latest available version from the JRE6 family when the jpi-version is specified by the RIA

    Issue Summary
    In Java 1.7 Update 71, Java 1.7 Update 72 and Java 1.8 Update 25 Deployment Rule Sets do not properly launch the latest available version from the JRE6 family when the jpi-version is specified by the RIA.  We've noticed this with Oracle Forms and Reports 11g where we have forms that specify Java 1.6 Update 20.  We used to be able to specify Java 1.6 Update 26 in our Ruleset, but now the only version a that works in our ruleset is Java 1.6 Update 20 which is the same version requested by the JPI-Version attribute of the jar.  The long term solution would be to upgrade Oracle Forms and Reports, however this isn't currently in the cards.
    RuleSet.xml Test
    Ruleset.xml

    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    &lt;ruleset version=&quot;1.0+&quot;&gt;  
    &lt;rule&gt;
       &lt;id location=&quot;*.javatester.org&quot; /&gt;
       &lt;action permission=&quot;run&quot; version=&quot;1.6*&quot; /&gt;
    &lt;/rule&gt;
    &lt;ruleset version=&quot;1.0+&quot;&gt;
    &lt;rule&gt;
       &lt;id location=&quot;*.internaldomain.name&quot; /&gt;
       &lt;action permission=&quot;run&quot; version=&quot;1.6*&quot; /&gt;
    &lt;/rule&gt;
    &lt;/ruleset&gt;
    Test 1 (Control)
    Installed Java Versions:
    – 1.7 Update 51 b13 (both x86 and x64 however x86 is invoked)
    – 1.6 Update 26 b03 (both x86 and x64 however x86 is invoked)
    Deployment Ruleset works as expected for both URLs
    Test 2
    Installed Java Versions:
    – 1.7 Update 72 (both x86 and x64 however x86 is invoked)
    – 1.6 Update 26 b03 (both x86 and x64 however x86 is invoked)
    The RuleSet works for JavaTester.org however on internaldomain.name we get the following error:
    With the trace logging turned on, I suspected the version attribute supplied by the RIA. I was able to trick Java by adding the following to my system deployment.properties file:
    deployment.javaws.jre.0.product=1.6.0_20
    deployment.javaws.jre.0.path=C\:\\Program Files (x86)\\Java\\jre6\\bin\\javaw.exe
    deployment.javaws.jre.0.enabled=true
    Because the RIA requests 1.6.0_20 it matches 1.6* from the deployment ruleset sooner than 1.6.0_26. However, if 1.6.0_20 is not available 1.6.0_26 should match according to the Deployment Rule Set documentation:
    http://docs.oracle.com/javase/7/docs/technotes/guides/jweb/security/deployment_rules.html
    The version of the JRE that is used is determined by the following order of precedence:
    1. The current version of the JRE is used if it is available and matches both the version attribute and the version requested by the RIA.
    2. The latest available version of the JRE is used if it matches both the version attribute and the version requested by the RIA.
    3. The current version of the JRE is used if it is available and matches the version attribute.
    4. The latest available version of the JRE is used if it matches the version attribute.
    If no version is available that meets the criteria, then the RIA is blocked, and a message is shown to the user. To provide a custom message, include the message element.
    As a result:
    If Java 1.6.0_20 is listed in the version requested by the RIA and 1.6.0_20 is listed in the deployment.properties file, #1 matches.
    If Java 1.6.0_20 is listed in the version requested by the RIA, but 1.6.0_20 is NOT listed in the deployment.properties file the #1 SHOULD match, but doesn’t. It used to match up-to and including JRE 1.7 Update 51 however the ruleset appears to no longer match in subsequent versions.
    #2 should never match with our current Deployment Ruleset. It would match if we specified 1.7* as a version in the Ruleset.xml.
    #3 used to be broken as well after JRE 1.7 Update 51 however this bug has been marked as fixed. See: http://bugs.java.com/view_bug.do?bug_id=8032781
    I have reproduced this issue with Java 1.7 Update 71, Java 1.7 Update 72, and Java 1.8 Update 25 when one of these versions are installed with Java 1.6 Update 26.

    I can't seem to edit this post anymore, for some odd reason.
    So here goes;
    I found this post in NVIDIA's knowledge base;
    When installing an after-market graphics card into a certified Windows 8 PC with UEFI enabled, the s...
    The interesting parts in this post are as follows;
    When an after-market graphics card is installed into a motherboard with UEFI enabled in the system BIOS, or if the system is a certified Windows 8 PC with Secure Boot enabled, the system may not boot.
    UEFI is a new system BIOS feature that is provided on most new motherboards. A UEFI system BIOS is required in order for the Windows 8 Secure Boot feature to work. Secure boot is enabled by default on certified Windows 8 PCs.
    In order to get the PC to boot with a graphics card that does not contain UEFI firmware, the end-user must first disable the secure boot feature in the system's SBIOS before installing the graphics card.
    Note: Some system SBIOS's incorporate a feature called compatibility boot. These systems will detect a non-UEFI-enabled firmware VBIOS and allow the user to disable secure boot and then proceed with a compatibility boot. If the system contains a system SBIOS the supports compatibility boot, the user will need to disable secure boot when asked during boot process
    This leads me to believe that the BIOS update that wrecked my setup was 9SKT58A/9SJT58A, which only contains one change;
    "Adds support for updating BIOS from a WIN7 BIOS to a WIN8 BIOS".
    I've just ordered a cheap UEFI-compatible GT640 from Gainward, so I hope I'll be able to try that out this weekend.

  • HT5622 Hi I have a Macbook air & iPhone 4. what do I need to do if I want to buy a book (ebook) or an application that is not available in the iTunes store in my area i.e. Africa (Egypt)? Do I need to open a different account in the iTunes store in the ot

    Hi
    I have a Macbook air & iPhone 4.
    what do I need to do if I want to buy a book (ebook) or an application that is not available in the iTunes store in my area i.e. Africa (Egypt)?
    Do I need to open a different account in the iTunes store in the other area i.e. USA ?
    Please advice
    Thank you

    You can only buy content from your own country's store i.e. the Egyptian store if you are in Egypt - you need to be in a country to use its store, so to use the US store you will need to be in the US and have a US billing address on your account. If there is an app or any other item that you would like to be buy that isn't currently available in the Egyptian store then you can try requesting that it be added, but unless the app's developer or rights-holder agrees to it then Apple won't be able to sell it there : http://www.apple.com/feedback/itunes.html

  • Data Source Z*** is not defined in the source system

    Hello All,
    I am facing a well known problem extracting data from R3 to the BI side. On both sides I've got SAP ALL.
    I created data source on R3 DEV side, tested it and it extracts data. I've replicated metadata on BI side and activated the data source. The problem starts once I create the info package as no data is availble in PSA.
    I went to extractor checker and tried to start the extraction and I could see the message: data source Z**** not defined in the source system.
    I tried to locate the data source through RSA5 and I cannot see that it is availble there.
    Can you please help and advise where the problem is?

    Hi Neb,
    It can be related to many issues, one of them can be RFC connection issue. Please check the link below :-
    Datasource xxx is not defined in the source system
    It might give you some of ideas. Also if possible can you tell what Datasource are you having problem with.
    Regards
    Sunny

Maybe you are looking for

  • Stock value is not getting updated in APO system From ECC automatically

    Hi All, Stock value is not getting updated in APO system From ECC automatically but if we do it manually from transaction CFM2 it will get updated. for this we are using EXIT_SAPLCSTK_001. I am using VL10A for delivery and VL06G for PGI I have also c

  • My ipod touch 5th gen has no sound through usb hookup-car

    I Have a kenwood ddx 370 touch screen HU installed in my car, and i can'y get sound from my speakers when its in ipod mode, and the wires are plugged in to the HU. I used to own a iphone 4, and a iphone 4s that both worked. now this issue is strange

  • InDesign CC (2014) and Word

    Intermittently, when a Word for Mac 2011 document is open and I am moving (over two screens) from that document to InDesign CC (e.g., copying and pasting), InDesign will not respond and its palettes disappear. I have to either 'Hide' the Word doc or

  • Cluster requirements

    I just need the minimal and cheapest configuration to learn Veritas Volume Manager and Sun Cluster features.I readed in Sun Cluster Admin Guide min. requirements are two nodes with 2 cpus each one and dont know if I can set up Clusters with two ultra

  • 100% packet loss

    Hi there, I get 100% packet loss whilst I am playing online on the Xbox, it only occurs on FIFA 13, I have contacted EA and they have said the packet loss occurs within the BT network, I was wondering if anyone else has the same problem and whether y