Hi Nikhil,
The Checklist,
1. Check the connection parameter at XI
2. Make sure ur function module is remote enabled
3. Make sure ur RFC exists for the same user, client credentials
Regards,
Prateek

Similar Messages

  • How to find out the inbound function module in the extended idoc

    Hi,
    how to find out the inbound function module in the extended idocs
    Thanks .

    through we41/we42 you can find the inbound function module.......
    or
    thorough we19(idoc test tool) ....
    give the input as message type or basic idoc..
    press exec...
    then you can find th button on application tool bar as inbound funtion module....
    from here also you can find..........
    <REMOVED BY MODERATOR>
    Khasimsa
    Edited by: Alvaro Tejada Galindo on Apr 14, 2008 1:34 PM

  • Where should i call the rfc function module? in xi or in r/3

    where should i call the rfc function module?
    for the synch scenario: file < -- >  xi <---> rfc
    i know the type of rfc is tcp/ip; but i'm not sure with the followings,
    and with some trials i can not even see any message via rwb even all the setting
    can be activated without errors.
    where should i create the rfc destination? in r/3 or xi
    where should i call the rfc via abap program? in r/3 or xi
    i guess the calling program should belong to the different server with the rfc itself....
    so confused....
    Thanks for your reply!!
    Jun

    if i create the destination in xi point to r/3, then i call the rfc use the destination in r/3 right ?
    The call doesnt use the destination in R3. XI has the RFC destination which is just used to connect to the R3 system
    but where i need to create the fm via se37? in xi or r/3 ?
    In R3
    Regards,
    Prateek

  • RFC Function module's where used list

    Dear Experts,
       I have a situation where in I need to change certain parameters/ the logic of an RFC function module. but before making the changes to the function module I need to know where this function module is used in various systems. So can some one tell me a way to find the where used list of an RFC function module in the calling system.
    Thanks
    -Amit

    It could be called from anywhere, theoretically, SAP or non-SAP environments.
    I hope you can rely on good documentation in your organization to find the potential callers, as each call must have been consciously implemented at some point.
    Also check with system administrators who might have a means to study trace logs for information on calling systems.
    Thomas
    P.S. the hard way would be to just do the change and see who complains later on

  • Regarding the RFC Function Module call from PI

    Hi All,
    I am working on one File to RFC interface, in which File adapter picks the file, this file data has to goto  2 function modules in SAP system. For this i added 2 Inbound interfaces in INTERFACE DETERMINATION and I developed 2 RECEIVER AGREEMENTS. In 2 RECEIVER AGREEMENTS i added single receiver RFC Communication Channel.
    Now i want assurance that once 1 st function module will execute completely, then only my second function module should be called. Is there any setting that i can do to make this sync?????.
    what is the use of  Send 'Confirm Transaction' in receiver RFC Communication Channel under Adavanced Mode.
    Thanks,
    Balu

    Hi,
    As per you requirement I would suggest to change your scenario as File To Proxy. It will much more easier and 100% sure to process second BAPI only after first gets successful inside the proxy.
    Pass the data from file adapter to inbound proxy and then inside proxy code you first call the first BAPI and use commit wrok. Once commit work is successful then you call the second BAPI otherwise rollback the changes.
    Example:
    Call First_BAPI
    <pass the data to it's import export parameters>
    Commit work.
    if sy-subrc =0.
    Call Second_BAPI.
    <pass the data to it's import export parameters>
    Commit work.
    endif.
    Note: If you are not very much comfortable with ABAP the discuss this with your ABAP team mate.
    Regards,
    Sarvesh

  • Issue with the RFC function module - parameters

    Hi,
        When i am creating RFC enabled function module, it was throwing an error like <b>'Reference parameters are not allowed with RFC'.</b>. I am implementing the test scenario to create BAPI, for that i have created table with 2 fields. My main intension is through RFC enabled function module planning to update the ztable.
       When i was creating RFC enabled function module, it was giving error. I remembered that  i need to use new structure when i create RFC enabled function module, so even i created structure also with the same fields of table fields.
       can you please let me know the solution for this.
    Thanks
    jaya

    Hi Ferry,
        Your solution is perfect. can you please explain the below information...
    Call by value                                                                               
    You pass the parameter with values. This means that the parameter     
         contents are copied both when the parameter is passed and when it is  
         transferred back to the calling parameter. For structures that contain
         tables, performance may be reduced considerably. Therefore, you should
         not do this.                                                                               
    I created the parameters with reference to table-fields, what do you mean by 'Call by value'check box usage there.
    Is it mean ...if i change the contents of the field in FM will it pass back to the structure which i refered to this parameter, in this case its table-field.
    Thanks
    jaya

  • Facing Problem with RFC Function Module

    Hi,
    I have created an RFC function module to get some data in table format.
    I have run the RFC in original system: It is giving the data.
    However, when I run this in target system, It is not giving any values.
    Could you please let me know, why it happens? I am not sure where I missed out.
    Thanks,
    Sandeep

    HI,
    i hope you are calling the RFC function module in the target system like this
    CALL FUNCTION <FUNC NAME> DESTINATION <DESTINATION NAME> . The destination should be logical system name of the source Logical system .
    Regards,
    Nagaraj

  • Message text available in java using RFC function module

    Hello,
    I wrote a function module with the ABAP statement
    MESSAGE .... RAISING PARAMETER_ERROR
    The java developer gets the PARAMETER_ERROR but no
    message text.
    Is the any way (e.g. exception class) to get the message text also.
    Thanks

    hi Michael,
    In the RFC function module use the table RETURN of type BAPIRET2 and instead of raising the error append the error in RETURN. later in your java code you can read this table RETURN and retrieve the error along with the error text.
    Hope this helps.
    Regards,
    Richa.

  • Error in RFC Function module

    Hi Expert,
    I am facign very strenge problem in the RFC function module.
    I have passed the paramters to the RFC function module and getting the result back into the table paramters.
    HWen i am trying to execute the RFC function module in the destination system , i am getting the result in the table paramerts.
    but when i am trying to excute the same uising program then i am not getting the same result in the table pramters , value of sy-subrc is also 0 . and there is no dump in the source and destination system. not sure why this is not able to get the result.

    Hello,
    Can you please post the actual ABAP code that calls the RFC? Are you checking for the standard RFC exceptions?
    Also have you manually tested the RFC in SE37, using the same RFC destination? (ie test it in the source system, calling the target system). This is to make sure that there are no communication issues.
    cheers
    Paul Bakker

  • ESS: RFC function modules

    Hi All,
    Can anybody give the RFC function modules which is called by the personal information -> Address service (Create, change)
    we are on ECC 5.0
    Thanks in advance
    Karthik

    Hi
    How to find which webdynpro sevice is calling which function module.i am getting lot of problems with the service.when i click on ESS services in portal either it shouwing only exit button or giving error.basically i want to how which ess webdynpro service is calling which function module in backend.please
    Prasad

  • SUP use own RFC Function module

    Hello there,
    I wanted to create my own RFC Function Module to get a list of purchase orders. So I could use my FM to create a MBO in Sybase WorkSpace. But I've got a problem, whenever I want to add a new MBO and start searching for my own FM, it can't find my Function Module....
    How can I use my FM in SUP workspace ?
    greetings,
    Amintah

    Hello,
    I have basically the same Problem.
    I developed a function module to retrieve maintenance orders from the SAP System.
    Therefore I created a package and assigned it to the PM (Plant Maintenance) application component.
    Now when I connect to the SAP Server in the SUP WorkPlace, there is only one folder called "Application Components". In its subfolder "Plant Maintenance" I can't find my own function modules.
    Do I have to search somewhere else or is there anything else I have to do first?
    Thank you for your help in advance!
    Regards,
    Daniel

  • Problem while calling an RFC Function Module in Background

    Hello,
    I have created a RFC function module for reading data from an external DB system. The FM calls an external RFC program (coded in C++ using RFC SDK), which delivers the required data. This external program is maintainged as an TCP RFC Connection in SM59.
    Further I have created a report, that calls the RFC function module to get the data from the external RFC programm.
    My problem is, when I call the report in foreground, everything works OK, the RFC connection works and data can be read from the external program.
    However, when I schedule the report to run in background as a job, the report is stating in the protocoll that there was a problem calling the defined RFC connection (although the connection is working properly at that time).
    More funny is, this particular problem with running in background occurs only in the productive system, in test and development system the report works correctly also while running as a job in background.
    Can you suggest the solution to this problem? Could it be something with authorisations or server settings?
    I will be on holiday for the next 6 weeks, so take your time to answer .
    Regards,
    Dusan.
    Edited by: Julius Bussche on Jan 22, 2009 7:19 PM
    Please read the forum rules about u r g e n t ...

    This is an external RFC server program, not a remote enabled ABAP RFC function module as the others seem to be assuming, right?
    Is it possible that your DEV and QAS systems only have one application server, but the PROD has many and dedicated one(s) for processing low priority background jobs?
    It might be that the target server of your TCP connection is not this BTC instance, and your RFC server is returning the data "locally" - so, into nirvana...
    Just guessing, but might be worth checking.
    Cheers,
    Julius

  • Debugging RFC function module from ECC to CRM

    Hi All,
    My requirement is to debug an RFC function module present in CRM(7.0) system from ECC(6.0) system. A report program in ECC will call CRM custom FM. I found many posts in SDN with the same issue and tried to implement suggestions provided there. But I couldn't succeed. The approach I followed is:
    I logged in to ECC report program and kept an external breakpoint just before the function module call.
    I logged in to CRM system, opened the function module and kept an external breakpoint there.
    In both the systems I provided the dialogue userid( id through which I log in to SAPGUI) in the system->settings->debugging option.
    In CRM I activated the external break point in  transaction SRDEBUG.
    Now when I execute the report program in ECC, control stops at the breakpoint. If I press F5 at the function call, control is not going to the external break point set in the CRM FM. I am getting output of FM directly.
    I tried with different settings like turning on the check box for IP matching and session breakpoint active immediate, switching to classic debugger etc. I also tried to provide the RFC user id instead of dialogue user but system throws exception saying only dialogue userids are allowed. I found that by inserting an infinite loop statement, control goes inside the RFC CRM FM but I prefer not to change the code.
    Please let me know if I missed anything.
    Thanks and Regards,
    Naren

    Hi,
    Debug RFC calls
    When an RFC function module is called it is usually not possible to debug the call, using the below techniques we can achieve the same. For this example we are calling an RFC enabled FM in ECC system from CRM system.
    Scenario 1: Calling a custom RFC FM
    STEP 1: Add an infinite loop in the remote custom Function Module (adding a u201CDO. ENDDO.u201D statement at the start of the FM would be enough).
    STEP 2: Execute your program in the CRM system. The execution stops at the RFC call, because of the infinite loop.
    STEP 3: Now login to the ECC system and go to transaction SM51 select the process which is executing the RFC and navigate to the menu: u201CProgram/Session->Program->Debuggingu201D this triggers the debugger session in a separate window.
    Scenario 2: Calling a Standard RFC FM
    When we are debugging a standard program we cannot add the infinite loop, hence we cannot go to SM51 and debug the work process. The RFC destination for the ECC system has a User specified, the RFC function module gets executed using this users credentials. Usually the basis team set up the RFC user as non Dialog user, this does not allow debugging. Contact your Basis team and get this changed to a dialog user enabling you to debug RFC function calls via the normal debugger.
    Note: User name configured in the RFC destination (transaction SM59) 
    Note: User type for the RFC User (transaction SU01D)
    Hope this will be helpful..

  • Get interface of RFC function modules in a remote system

    Hi,
    my goal is to write a report which checks if DDIC structures in two systems fit together when I use RFC`s.
    I have the destination and the name of the RFC.
    Can somebody tell me if I can get a list of the Importing/Exporting Parameters of this RFC? Maybe even with a typedescribtion?
    Thanks for you help.
    Best regards
    Lars
    Edited by: Lars-Eric Biewald  on May 21, 2008 8:39 AM

    Hello ,
    Thank you for your quick help.
    Here I have 3 ECC 6 system .
    1 Central systen
    2 Slave system
    Data will be updated to 2 slave system using RFC function module .
    We've already the SAP address, Client, User name , Password.. of the remote system
    So here how we will create RFC in SM59 to be used in the RFC call ?
    We will transfer the username, password , client in the RFC function module/..
    Here I do not know how to create RFC connection in SM59 and how to use them in ABAP
    Could you please help me ????
    Thanks

  • RFC function module without RETURN parameter thows error in XI. Please help

    Hi Experts,
       I have a File to RFC scenario in XI. The RFC function module that I am using at the receiving end does not have "RETURN" parameter. So when I test my scenario I get "RETURN" parameter not found error on SXMB_MONI.
    So is it mandatory that RFC function module must have RETURN parameter when used in XI?
    Is there any work around to avoid the error without changing the RFC function module?
    Please help!
    Thanks
    Gopal

    In my senario the QOS is best effort because it is a Sync.
    But the function module is sync in nature as it is returning a parameter called SO_Docs and Ret_Msg. The Ret_Msg contains the error info but it not of BAPIRET2 type.
    So is there any way to avoid this error when my QOS is best effort?
    Please help!
    Gopal

Maybe you are looking for

  • Urgent help with Index page needed

    Can anyone help? I use Dreamweaver 8 to modify and update my work's website and I've come across a very strange problem that I haven't seen before. I amended a news page, entitled 'news.html' and uploaded it as normal last week. I also put a few new

  • Adding HTML to a "start" page

    Hi, Opening iWeb, I am now getting a template "start" page as if it's my first time, so somehow I've lost all of my preferences after juggling a recent upgrade (am I correct that this would be the "com.apple.iWeb.plist" file?). I'm wondering if there

  • Oracle ODBC driver: NO_DATA_FOUND blocked

    Hello, I found that NO_DATA_FOUND exceptions thrown inside stored_procedures are sometimes not propagated to ODBC errors. This happens with the Oracle ODBC driver, but not with the MS one (the MS one does propagate the exception/error). Test-Procedur

  • MSRV* Reports: How to add Vendor name?

    howdy gurus! Appreciate very much for any guidelines on how to add vendor name in MSRV* reports. Cheers, Ron

  • Linkys ac1600 and macbook pro late 2013

    Hi i have linksys AC1600 and Macbook pro LATE 2013 , when i try to search for my 5GHZ network i cannot found and i cannot know how to turn it on. can anyone please help on this?