Hi Gurus,
I Have small doubt we have option like Test message at RWB
RWB--->COMPONENT MONITORING--->Adapter engine --->Test message ,what is the purpose of this test message option at Adapter engine.
It is same as sending data from Integration engine if so when ever we are sending data from AE we are getting some issue .Can any body clarify this.
Thanks
Madhu

Hi Madhu,
Check out the below thread:
https://scn.sap.com/thread/1402225
You can also check out this excellent blog for extra information:
http://scn.sap.com/community/pi-and-soa-middleware/blog/2014/02/17/howto--send-test-messages-to-the-adapter-engine-to-an-integrated-configuration
Regards
Bikash

Similar Messages

  • Testing through RWB under Adapter Engine

    Hi All
    I know i can test my scenario through RWB through Test tab.
    The problem i am facing is---- when i am testing using Integration Engine after providing necessary details i am getting a message in moni thats fine but when i am testing the same scenario using Adapter Engine by giving same details i am getting error     "Error when sending message: 403 Forbidden"
    what could be the problem?
    Regards
    Dheeraj Kumar

    Hi Aamir
    the test Tab under adapter engine in RWB is used when you have de-centralized adapter engine.
    check this page http://help.sap.com/saphelp_nw04/helpdata/en/25/9c2f3ffed33d67e10000000a114084/frameset.htm its saying This Adapter Engine is a central Adapter Engine its not related to de-central Adapter Engine.
    This Adapter Engine resides under Integration Server.
    so i believe the prob is because of authorization, if i am not correct please correct me, by this answer i am not telling you that you are wrong i am just putting my view.
    Please check and if i am wrong correct me.
    Regards
    Dheeraj Kumar

  • PI 7.1/RWB/Component/Monitoring/Adapter Engine/Test Message/403 Forbidden

    Hello guys!
    During performing PI 7.1 Readiness Check I have to perform a test message under Runtime Workbench\Adapter Engine\Test Message.
    After processing i receive following error:
    Error while sending message: 403 Forbidden.
    Does anybody know the cause?
    Many thanks in advance!
    Jochen

    Hi Sreeni!
    Direct hit!
    This was the problem! Missing role!
    Many thanks to you!
    Additional Information for all:
    Readiness Check (PDF)
    A compilaton of simple and advanced checks for Process Integration 7.1 (PI 7.1)
    Page 44
    SAP Note 817920 - XI Readiness Check 3.0/7.0, 7.1
    Regards,
    Jochen

  • No Integration Server under Adapter Engine at Communication Channel

    Hello all,
    This is new PI7.0 install.
    I configured a file Adapter communication channel for an Integration Scenario.
    At field "Adapter Engine" under Parameters tap I am not able to select the Integration Server.
    Pull down menu is empty.
    I did sxmb_adm and blog 6077 that got "Integration Server" in file adapter. Later to that file to file scenario worked yesterday. However after java+abap stack complete restart (to cleanup unwanted manually created business system of type WEB AS ABAP) the problem came back today.
    I repeated again same blog /people/venugopalarao.immadisetty/blog/2007/03/15/adapter-engine-cannot-be-found-in-integration-directory   sxmb_adm, sldcheck, rz70 all looks good, but no luck.
    There is a note from forum to change the content maintenance under
    SLD->Administration->Content Maintenance->Subset (Landscape description)...
    Need some pointers on what to change & get the file adapter to work? Thanks.
    Another observation is all adapters got empty menu (no Integration Server). However IDOC, HTTP got integration server populated.
    ====================
    Re: No Integration Server under Adapter Engine at Communication Channel config  
    Posted: Sep 12, 2007 4:46 PM    in response to: Jochen Schertel      
    Hi All,
    the problem was related to missing some Associations under Contend Maintenance for the Integration Server.
    After implementing again, the problem was solved!
    Regards,
    Jochen
    ====================

    Hi Jochen,
    Can you please check following parameters in sxmb_adm on your application server.
    Goto TC : sxmb_adm...select Integration Engine configuration n check whether you have maintained global configuration data as
    Role of Business System  : Application system
    and Corresponding Integ. Server : http://xi hostname:port/sap/xi/engine?type=entry
    Also check if you have created following RFC destinations:
    1. INTEGRATION_DIRECTORY_HMI(H)
    2.LCRSAPRFC (TCP/IP)
    3.SAPSLDAPI
    Nilesh
    Nilesh

  • Adapter Engine: Test Enviroment

    Hello,
    I installed a stand-alone Adapter engine in my pc that interconect with the XI server.
    I configure the SMB parameters but when i use the test enviroment options i have this result:
    java.net.ConnectException: Connection refused: connect
         at java.net.PlainSocketImpl.socketConnect(Native Method)
         at java.net.PlainSocketImpl.doConnect(Unknown Source)
         at java.net.PlainSocketImpl.connectToAddress(Unknown Source)
         at java.net.PlainSocketImpl.connect(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at java.net.Socket.<init>(Unknown Source)
         at com.sap.aii.messaging.net.ClientHttpImpl.call(ClientHttpImpl.java:101)
         at com.sap.aii.messaging.adapter.SinglePayloadClient.doPost(SinglePayloadClient.java:218)
         at javax.servlet.http.HttpServlet.service(HttpServlet.java:760)
         at javax.servlet.http.HttpServlet.service(HttpServlet.java:853)
         at com.sap.aii.messaging.adapter.Zone.service(ModuleGUIBrowserEngine.java:1072)
         at com.sap.aii.messaging.adapter.HTTPRequest.run(ModuleGUIBrowserEngine.java:370)
    What could be happening?
    Thanks a lot,
    Enrique.

    Hi Enrique,
    Check the targetURL parameter in the message header you are sending. Are the host name and port number correct?
    A "connection refused" exception occurs when there is no service listening at the host and port you are trying to connect to.
    Regards,
    Thorsten

  • Adapter Engine test tool doesnt work

    Hello
    I try to send a message from runtimeworkbench
    I chose Component Monitoring -> Integration server -> Adapter Engine
    And I put the paramets of the message ( message interface,namespace..etc.)
    then I put user and password
    and the url is
    http://server_name:52000/MessagingSystem/receive/AFW/XI
    I click on send,I get a message "Messasge sent"
    but the message doesnt appear on sxmb_moni
    any idea how to solve it?
    thx
    Shai

    Hi,
    As you state, check the user you're sending the message has necessary authorizations. You probably got an HTTP error 403: unauthorized. For overview of http errors, you can refer here:
    Try with user PISUPER for example. If you get past the authorization, the message should get to the IE.
    Post any other problems if arised.
    Regards,
    Gökhan

  • No entry for adapter engine in CPACache

    Hi all,
    This is a new installation of PI 7.0. Some of the issues we are facing are:
    1) ID -> cache notifications -> unable to determine the name of central AE from SLD
    2) Integration Builder -> Admin -> cache overview -> refresh objects fails
    3) RWB -> Cache connectivity test for AE fails
    4) SXI_CACHE -> goto Adapter Engine Cache -> No Entry under Adapter Engine Connection data cache 
    5) RWB -> Adapter Monitoring : Only JPR is shown. All the adapters need to be shown as well. 
    6) SLD -> Technical Systems -> XI -> Integration server does not show the domain name. But all other components have a consistent domain name.
    It seems to me that somehow the adapter framework hasnt been registered in the SLD. Do we need to do this manually?
    Any help on any of the above issues is greatly appreciated..
    thanks!

    Hi Lasya,
    Please have a look at this thread..
    Inconsistence Adapter Framework
    cheers,
    Prashanth

  • Error: Unable to find any Adapter Engines

    Hi all,
    I am trying to execute a very simple scenario.
    A xml-file is read from a drive by the XI system.
    XI reads the values.
    Another xml-file containing some parts of this info is written to another location.
    I see that the file is read and removed.
    However, when I check the monitoring I find follwing error message:
    <SAP:Error xmlns:SAP="http://sap.com/xi/XI/Message/30" xmlns:SOAP="http://schemas.xmlsoap.org/soap/envelope/" SOAP:mustUnderstand="">
      <SAP:Category>XIServer</SAP:Category>
      <SAP:Code area="INTERNAL">AE_DETAILS_GET_ERROR</SAP:Code>
      <SAP:P1>af.cx1.cernum05\cx1</SAP:P1>
      <SAP:P2 />
      <SAP:P3 />
      <SAP:P4 />
      <SAP:AdditionalText>Exception in SLD client: AbapSLDRequestHandler.exe: Unable to find any Adapter Engines</SAP:AdditionalText>
      <SAP:ApplicationFaultMessage namespace="" />
      <SAP:Stack>Error when reading the access data (URL, user, password) for the Adapter Engine af.cx1.cernum05\cx1</SAP:Stack>
      <SAP:Retry>M</SAP:Retry>
    </SAP:Error>
    Is there some configuration missing?
    We are running XI3.0 SP9.
    Thanks in advance.
    Kind regards

    Hi Geert,
    My first guess is that something is not configured correctly. Try checking if your adapter engine is registered in the SLD:
    In a browser, goto http://host:port/sld. Choose Technical Landscape. Under Technical System Type, select Exchange Infrastructure. You should have an entry like:
    "Adapter Engine on cx1.cernum05"
    If not, check the settings in Visual Administrator for the SLD Provider service and test the update from here.
    Also check your receiver communication channel. Under Adapter Engine, it should say "Integration Server". If it says e.g. af.cx1.cernum05, your SLD has not been updated correctly.
    Regards,
    Thorsten

  • In the XI Szenario i cannot assign Adapter Engine in Communicationchannel

    Hi There,
    i have a new problem. I imported now the whole Scenario from my XI Cons System into the XI Prod System.
    After that i have to reconfigure the Communication Channels.
    URL etc.. but in Prod System i cannot Assign Integration Server to Adapter Engine..
    i maked a screenshot so you cann see what i mean:
    (If you cannot see the screenshots.. please provide me a Mail Adress.. then i can send them to you)
    This is our Consolidation System:
    http://img16.imageshack.us/img16/7546/xik1.jpg
    You see what i mean in the read mark.
    And here you can see our Prod System.. i cannot Assign here the Integration Server...
    http://img14.imageshack.us/img14/4581/xip1g.jpg
    Can you tell me whats wrong here?
    Thanks
    Bjoern

    Hi,
    please check this threads, this may help you
    Can not select Integration Server for Adapter Engine in File adapter
    No Integration Server under Adapter Engine at Communication Channel config
    Regards,
    pradeep A.

  • Adapter Engine URL missing in RWB

    Hi All,
    In my newly configured PI 7.0 system, the Adapter Engine URL is missing at the fol. location:
    RWB -> Component Monitoring -> Adapter Engine -> Test Message.
    But when I open SXI_CACHE -> AE Cache, I am able to see the url http://pidev:50000/MessagingSystem/receive/AFW/XI     
    I think that this means that my ABAP stack is configured properly, but JAVA stack has some problem for Adaptr engine.
    Please confirm if I am right and how to resolve this.
    regards,
    Piyush

    Hi,
    Are you using the FQHN?
    Check also note #764176 if you have components missing on SLD.
    Last, you may want to configure your system in order to check each of the steps.
    Use this link -> Wizard-Based Basic Configuration:
    http://help.sap.com/saphelp_nw70/helpdata/en/a0/40084136b5f423e10000000a155106/frameset.htm
    Regards,
    Caio Cagnani

  • Difference between Testing Message in Integarion Engine and Adapter Engine

    Hi Experts,
    in project, we always test message in runtime workbench>component monitoring>integration engine-->Test Messge
    however, i also find that in  runtime workbench>component monitoring>adapter engine also exists a Test Message tab.
    we don't have access to test messages in this tab, so can anyone tell that what is the difference between testing message in integration engine and adapter engine?
    thanks in advance.

    The usual flow of messages in scenarios which use adapters at both sender and receiver end is as follows
    Sender system -> Adapter Engine -> Integration Engine -> Adapter Engine -> Receiver system
    When you use the testing option in IE, then you are basically posting the message directly to the Integration Engine.
    When you use the testing option in AE, then you are trying to post the message to the adapter engine, which will then forward the message to the Integration Engine. IN this testing, you are also testing the sender adapter also.
    Regards,
    Ravi Kanth Talagana

  • RWB - Cache Connectivity Test - Adapter Engine shows error

    Hello Friends,
    In our one production system (PI 7.1), while do 'Cache Connectivity Test' from RWB -> Component Monitoring, it shows the following error for Adapter Engine under Integration Directory.
    Error:
    Cache notification from Integration Directory failed Error when accessing the System Landscape Directory.
    No SLD elements of type SAP_XIAdapterFramework found
    But, Integration Server - ABAP, Integration Server - JAVA shows green color. The messages are flowing through the Adapter Engine fine. i.e I am seeing 2 Adapter Engines under Integration Server in Component Monitoring. One Adapter Engine is in grey and another Adapter Engine shows green color.
    When I click the grey color adapter engine, it immediately turns to red color and some different host name url is displayed (http://<wronghost>:53000/AdapterFramework/rtc).
    So, what could be the problem ?
    Kindly clarify, friends.
    Thanking you.
    Kind regards,
    Jegathees P.

    Hello Jegathees
    Apply the solution in note #804124 HTTP communication with XI Adapter Engine fails. Set the parameters:
    SLD.selfregistration.hostName     
    SLD.selfregistration.httpPort     
    SLD.selfregistration.httspPort    
    as described in the note.
    Regards
    Mark

  • CPALookupException while sending a Test message to Adapter engine

    Hello Experts,
    I am getting following exception while sending a test message to Adapter engine through Runtime Workbench.
    Error while sending message: com.sap.engine.interfaces.messaging.api.exception.ConfigException: ConfigException in XI protocol handler. Failed to determine a receiver agreement for the given message. Root cause: com.sap.aii.af.service.cpa.impl.exception.CPALookupException: Couldn't retrieve outbound binding for the given P/S/A values: FP=<Configured Party>;TP=;FS=<Configured Communication component>;TS=;AN=<Configured Outbound Interface>;ANS=<Configured Namespace>
    This scenario works fine when I submits the message through Integration engine. So ID configuration is perfect. Also cache contents are upto date.
    Thanks in advance.
    Regards
    Rajeev

    Error is clearly saying that it is unable to find receiver agreement for that particular interface.
    Please check your receiver agreement for the interface.
    If your receiver agreement is fine then do CPA cache refresh using following URL:-
    http://<host>:<port>/CPACache/refresh?mode=full

  • J2SE adapter engine and SSL testing

    Hi there,
    We are currently doing a B2B scenario whereby SAP XI sends a message to the J2SE adapter engine in the DMZ and then that sends the message via HTTPS / SSL to the receiving service....
    In order to test that the HTTPS / certificate etc worked I wrote a small Java application and dialled out of the network. I inserted the DER file into my CACERTS file on my local machine using the keytool as a "trusted certificate". The Java application worked 100% and did the SSL handshake fine and POSTED the data fine as well......
    Now I am no expert in the J2SE adapter engine but decided to try testing the same SSL connection using the J2SE adapter engine from my LOCAL machine with me dialled out onto the Internet.
    I logged into the J2SE adapter engine and imported the same DER file into the engine  (actually inserted into the "truststore.jks" file). I them went into the "Test Environment" of the J2SE adapter and have been trying to test.....
    I have a few questions:
    1. Do I have to use a P12 or PFX file for this sort of communication? Reason I ask is that with the Java application all I needed was the DER file?
    2. In the full blown scenario do I have to have SSL configured between XI and the J2SE adapter engine as well? Or can that stay as HTTP?
    My basic config for the test is roughly:
    WS.targetURL=https://someserver:4433/soap/someInbox
    WS.SOAPAction=CustomSoapAction
    SSLauthentication=true
    Do I really need the following two?
    SSLcertificate=somecert.p12
    SSLcertificatePassword=somepassword
    From my logic all I should need if the DER file loaded into the J2SE adapter which I have done......
    Has anyone done successfull SSL / HTTPS testing from the J2SE adapter engine using the "Test Environment"?
    Any advise would be greatly appreciated
    Kind regards
    Lynton

    Hi
    Not a answer to your question but why use the J2SE adapter engine in the DMZ and why not the J2EE Decentral Adapter Engine?
    Regards
    Bhavesh

  • Sand box Non-central adapter engine entry is shown under development rwb

    Hi All,
    Recently we had a sand box which is a sytem copy of our development server, and everything works fine now.
    I have observed a strange issue here is, in the developement rwb under the Non-Central Adapter engines I see a entry as "Adapter Engine T49 (sand box host name)" the SID seen here is a sand box SID, and till today we never installed any non-central adapter engine either on dev or sand box, I am suprised to see this entry, can some one
    please help me to understand why is this sand box entry is shown under development rwb and where can I set this or where how can I delete this entry.
    Surprisingly I do not see the same non central adapter engine entry on sand box rwb.
    All the servers are XI 3.0 (SP 19).
    Thanking you in advance..
    Regards
    Sonali
    Edited by: Sonali R on Sep 14, 2009 10:59 AM

    Hi Sonali,
    The adapter and integration server engines gets registered with the data in SLD. Please check SLD associations for all XI classes.
    Best Regards
    Raghu

Maybe you are looking for

  • ITunes split my compilation CDs into singles!

    As an inexperienced user of iTunes, I'm having some problems with the software. My compilation mp3 albums, which all have the same album name tag but different artists, have been split into singles by iTunes. I used Magix software to produce the mp3s

  • PNG files with a transparent background have background in Internet Explorer.

    I have two banners that are rounded rectangles for a website. The have quite a few gradients in them, with a gif it looks distorted. I can't use jpg, so I went with png. In dreamweaver it shows the banners as having no backgrounds, but in Internet Ex

  • ACS not authorising Security Manager devices

    Hi I have a setup ACS 4.1 CS-Manager 3.2.2 I have intergrated the CS-Manager into ACS with no problems. However when I try to add devices into the CS-Manager I get the message "The Device is not in the Cisco Secure ACS" I have one wildcard entry enco

  • X-Fi Xtreme Gamer Fatality Pro Vista x64 Drivers Unavailabl

    How come there arent any dirvers for my X-Fi Xtreme Gamer Fatality Pro for Vista x64 ? Keeps saying.. "No Update Available"Message Edited by RudeBoyNvidia on 06-26-200709:50 PM

  • Get averages from a cursor

    I Have something like this... CURSOR my_cursor IS SELECT avg(a),avg(b), avg(c), avg(d) FROM sch.mytable; How would i fetch this into a ROWTYPE variable? I keep getting null back.