UOM error

while doing the gr with refe. to PO in migo i am getting error
specify at least 1 unit
sloc is wm managed and base unit of measurement mentioned in materila master is KG and it is also maintained in the tc CUNI
please reply ASAP

Hi Rahul,
I've found this thread, please check it:
Re: Urgent- Update was terminated - TCode MIGO_GR
(SPRO > LE > WM > MAster Data > Define control parameters for warehouse number)
Regards,
Csaba

Similar Messages

  • UOM error in Material master.

    Hi
    When we log on to Spanish language, we are getting error in material master for Unit of measure, that the unit of measure has not been created in the language ES. But same UOM has configured in EN language and its working fine for material, while in Spanish language it appear as *** with error details,
    Could you please suggestu2026
    regards
    Vanraj

    Hi,
    Extactly you are right..you got to Logon in Languange ES and create the required UOM in t-code CUNI...
    this shuld solve the issue..try and revrt back..
    Also,In CUNI on top menu Go to-Translation-UOM here maintain Source lang to Target lan
    Reg,
    JJ
    Edited by: Jagsap on Apr 20, 2010 4:10 PM
    Edited by: Jagsap on Apr 20, 2010 4:15 PM

  • UOM error while creation of Shopping cart.

    Hi guys,
    Can any one help me?
    I have a problem with UOM as PCE = piece, The UOM is already there in the SRM and found that the same is not there in my backend system.
    So now I have maintained the UOM in the backend system  also with that of same in the SRM system. with following attributes.
    Internal measurement unit as PCE
    Commercial name = PCE
    Technical name = PCE
    ISO code = PCE
    in application paramentes I have checked the the box commercial measure ment unit.
    I mean I have maintained the same as that of in SRM.
    Now when I tried to create a shopping cart and approved it. it shows as error in process UOM  not defined in the backend system. Is it so the same ISO code has been assigned for more than 2 UOMs?
    Please suggest how to resolve this? also Do I need to tick the primary code box also?
    Best Regards,
    Sairam.

    Hello Laurent,
    Thanks for your reply, But let me explain you, The UOM PCE = piece is existing in the SRM right from the beginning , which has not corresponding UOM maintained in the backend system.
    So now I simply maintained all the attributes of UOM, same like in the SRM.
    By simply ticking the Primary code will this solve my problem? or, shall  I really have download the UOM through R3AS  from backend to SRM?
    Can you please suggest?
    Best Regards,
    Sairam.

  • About UOM error of PO

    Dears,
    I create a PR, the account assignment is K.
    And the PR's UOM is YR...
    When I transformed PR to PO, i want to change the PO's UOM to SET.
    After that I GOT AN ERROR MSG OF 06480.
    Show that "Order unit SET not convertible into unit YR of requisition"
    Is there any suggestions about the problem?
    Thanks in advance for your help...

    Both UoM are not in same dimension. Check this in CUNI.   In standard system, you can converts KG to TON or vice versa because, both belong to the same dimension (MASS) in CUNI. 
    Example:   
    In CUNI, KG belongs to MASS Dimension  TON, MG, LB are also belongs to MASS Dimension and each of these have a predefined Conversion Rate. So, you can convert them from KG to TON or TON to KG without any issues.
    You need to make a similar set up for your U/Ms  in CUNI Tcode by putting them in same dimension and havind a conversion rate with the Base ISI U/m
    Hope this helps.

  • Invalid UOM error

    Hello Experts,
    Whenever i open item in Item master data to see details an error showed only "Invalid UOM  "
    Help me out what things i will check to remove this error
    Thanks & Regards

    Hi Manish,
    Here is what I have setup.  I believe this is correct but am still getting the error message.
    For Part # A120BB:
         Purchasing  U of M = ea
         Sales U of M = ea
         Inventory U o M = ea
    In Admin > Setup > Inventory > Length and Width U of M:
         Code = ea
         Unit Name = Each
         Volume Code = ea
         Length = 1
    In Admin > Setup > Inventory > U of M: Weight U of M:
         Code = ea
         Unit name = Each
         Weight = 1
    I have also tried changing the name to 'ea'; still the same error.  Client is on SAP 2007 A SP01 PL10

  • UoM error while doing partial loading in O4G1- TD Transport

    Hi experts,
    while doing partial loading error pops up which says UoM not set in customizing..
    Have checked all settings for Uom its ok..
    what else could be the issue..pls help.
    regards,
    VP

    Hi,
    Data records for package 39 selected in PSA - 2 error(s). Record 5129 :No SID found for value 'EMN ' of characteristic 0BASE_UOM . Record 5132 :No SID found for value 'EMN ' of characteristic 0BASE_UOM
    The issue with record no. 5129 and 5132.
    In PSA check errorneous records and it will display only the error records, you just edit as per the require and try reloading into cube.
    Deleting single record is not possible.
    Let us know if you still have any issues.
    Reg
    Pra

  • Unable to load Materials from ECC to Cloud due to UoM errors

    Dear experts,
    We are working to set up the ECC integration with C4C through HCI, we maintained all necessary settings in ECC and HCI.
    When we are trying to send Material data from ECC to C4C they are failing in Cloud with error "Solve Configuration Issue in Code List Mapping for field MeasureUnitCode with value PCE", but we maintained all the Material specific UoM in cloud and mapped them with ECC values in Code List mapping.
    Can someone give your input in which scenario this error comes and how UoM Conversions gets updated in Cloud, like ECC Material master.
    Thanks & Regards
    Naren..

    Hi Naren,
    we have experienced a similar problem when loading materials from ECC to C4C.
    What we have seen is that you have to:
    - maintain the basic UoM of the material in C4C
    - maintain all the UoM mentioned in the conversions for the material
    - maintain the Code Mapping for these UoM if the codes are different from ECC and C4C
    Nevertheless we had a problem for materials that in ECC in the UoM conversions section of master data have conversions like: 1 MTR = 1000 MMT (1 meter = 1000 millimeter).
    In C4C we have activated UoM MTR and MMT, and MMT is defined as 0.001 MTR. So the conversion rate is defined in C4C.
    If ECC sends this conversion for the material to C4C we have an error.
    We have solved it modifying the mapping in HCI for the iflow *.erp2cod.material.*: in the mapping, the conversion element is not transferred if the basic UoM is MMT and the conversion UoM is MTR.
    This is an example and a simple workaround that allows us to load these materials.
    Maybe could be useful.
    Regards
    Piero

  • UOM error in F4 help

    Hi All,
    I am facing a problem in quality server. When I click on f4 help for UOM field (which is UNIT field of structure BBPS_SC_APP_ITEM) I get this message "Internal unit KNM, language EN is not maintained" though F4 is also displayed. I just fail to understand what is wrong as it is workin fine in development server. I have also checked all the configurational settings.
    Any help will be appreciated.
    Thanks.

    Is it happening for only one unit or for all units? Did you check the "language" of the UOM that you are using ?
    Trnx: CUNI --> ISO codes -> select the UOM -> Utlilities -> choose language -> select the applicable language.
    Check the same for dimensions as well.
    As far i know, apart from this there is no dependent relations to UOM and language. If there is any alternative to it, i would love to learn it.
    Hope this helps,
    Cheers, Renga

  • Excise extraction UOM error

    Dear All,
    We have a problem with excise register extraction. For a material we maintain basic unit of measure as TON and unit of issue as KG. The problem is in excise register RG23A extraction i.e.
    we buy 10TON of the material so rg23a part 1 up dates as 10+
    Now we issue 1000 kg now in register rg23a updates as 1000-  so balance quantity we get as 10 - 1000 = -990
    really it should be 10ton - 1 ton (1000) = 9 but this is not happening please help..
    Thanks i advance
    Regards
    Arjun

    Hai
    I have maintained Base UOM as TON and unit of issue as KG. conversion 1000kg = 1 TON
    Dear brinda
    Where should this user exit be applied at MIGO? Will the exit cause the updation of rg23a part1 in base unit of measure?
    Is there any note available for this purpose?
    Please help

  • Billing doc error due t copa standard quantity

    Hi  I am facing an issue .this is regarding the error while releaseing a billing doc the errortranslating the quantity to the COPA standard quatity.
    in material master i checked the unit of measure is SET and in copa KEA6 VVAUM( Alt Uom)
    Error translating the quantity to the CO-PA standard quantity
    Message no. K/832
    Diagnosis
    Customizing in Profitability Analysis CO-PA allows a standard quantity field to be updated.
    An error has occurred in the present document while the standard quantity field "VVAUM" was being supplied.
    The base unit of measure "SET" could not be translated into the standard unit of measure "M3" for the material "B/CAL/PROJECT5".
    System Response
    It is not possible to process the document again.
    Procedure
    1. If required, maintain the unit of measure "M3" as an alternative unit of measure in the material master for the material "B/CAL/PROJECT5".
    2. In certain cases, you should check whether derivation of the unit of measure for the CO-PA standard quantity field "VVAUM" needs to be changed in Customizing for CO-PA characteristic derivation
    This is billing docments needs to be released . what is the problem some body can help me to resolve the issue
    Arjun

    Hi
    I am assuming that you want to update qty in COPA with UoM M3
    In MM02 - Maintain conversion of SET to M3
    In KE4MS - Maintain M3 as the Standard Unit of Measure
    In KE4M - Assign SD Qty field (FKIMG) to VVAUM
    BR,Ajay M

  • CHENGEING uom

    Dear Experts
    I am unable to change the UOM error message re displayed is
    Standard cost estimates for the current period already exist     
       Valuation area                                                
              A1                                                       
              A2
    Thanks
    Raj

    Dear Experts
    While i am changing Unit of measurement of material P3402378 to "KG" from "001" in TCODE MM02, system shows error message.When i click on error messge it displays.
    Valuation exist in current period for material  P3402378 in area
      A1
      B2      i.e my vlauationareas defined in system.
    Please explain how to change Unit of Measurement for this material.
    Sorry For previous post it was not having proper information.
    Regards
    Raj

  • Service Ticket in CRM 7.0

    Hello,
    We are upgarding CRM 5.0 to CRM 7.0. Client is using Service Ticket in IC Web Client in CRM 5.0. As part of the project, we don't want to migrate it to service request. We will continue using service ticket in 7.0 as well. But client wants to use WebUI screen for service ticket. I know that SAP does not provide any WebUI screen for Service Ticket. But I have noticed that when I click on service order link in CRM 7.0 IC Web, it is giving me a pop-up to select the document type. One of them is service ticket. I believe this behavior is because of the same business object type 'Service Process' for order and ticket. Can we just use this WebUI screen to maintain the service ticket? I also know that there are certain validations in the service ticket user interface. But, if the process works fine for our requirement, then can we use WebUI screen?
    Please let me know as soon as possible.
    Thank you,
    Sapan Shah

    Hello,
    For the pricing error, if no pricing date required, please check of the pricing relevency at item category customizing setting under both transaction category BUS2000115 and BUS2000116.
    For the UOM error, please check whether a base unit and sales unit for this dummy product are maintained and the organizational units used in the order are assigned.
    Alternatively:
    you can use the BADI: CRM_SERVICEPROD_BADI, there you can create your own implementation and change the default product investigation to your individual product.
    I hope this could be helpful.
    Best regards,
    Maggie

  • Error while changing the UoM in material master

    Hi experts....
    I am not able change the UoM in the material master. Even if,  all the PR , PO and reservations are cancelled .
    It still gives me error message " Manual  Reservations already  exists "
    Thanx
    Ganesh

    Hi
    may be some entries got not cancelled properly and entries got locked.
    Just check in SM12 if no entries are locked.
    regards
    Sidi

  • Error Message while entering alternate UOM in BOM, despite being maintained

    Hello PP Angels,
    I wish for a solution for this issue.
    When I am creating a  BOM,
    while entering the line item, with a material number,
    when I enter  the UOM for the material, which is the alternate UOM maintained in the material master (already)
    I am still getting this error message
    "Unit of measure DKG not supported for material XXXXX in plant XXXX"
    Wishing for a solution at the earliest.

    Hi,
    Thanks for the replies, but my issue is not yet solved.
    I have checked that earlier
    It works that way
    But my issue is i have data ( in a different server), such that
    the bom is accepting a UOM that is defined in the Alternate UOM and not maintained as the Unit of Issue.
    I am trying to replicate the same thing here but when I add an alternate UOM, which is not in Unit of Issue, then error message is thrown while bom creation.
    Are any configs to be checked
    Awaiting more responses.
    Thanks

  • UOM group error while material document posted throgh BDC( MB01)

    Hi All,
    we are facing issue while posting material through MB0-goods reciept
    error "UOM group not maintaineed for 'XXXXX" material" for some line items,
    and i have checked in material master data, UOM group not maintained for some material,
    even after maintaind UOM group for those material's still we are facing same problem,
    as i checked in BDC code there is no validation for UOM group,
    if we posted same PO manual, document posted successfull,
    please suggest me.....why this error message coming eventhogh UOM group mainted?
    Regards,
    Suresh.D

    check this link:
    Updating Function module for Material master (UoM)
    BAPI for MIGO
    cheers
    Aveek

Maybe you are looking for

  • Half of my music will not show up on my iPod, but is perfect on my PC

    I have a Toshiba laptop running Vista that I bought last summer. A few months ago, my iPod just stopped coming on, or charging at all, so I stopped using it. I tried to use it again 2 weeks ago, and it loaded up all my music and worked perfectly, lik

  • How do I get an actor to wait for its nested actors to stop running before stopping itself?

    I'm developing a series of projects that are based on the Actor Framework and my actor dependency hierarchy is starting to get some depth. One of the issues I'm facing now is making sure that each actor will only stop running (and signal this via a L

  • Display size external Monitor

    The resolution of the YOGA 13" display is that high, that one has to use 200% size in Windows 8.x. If I connect to an external monitor with HD resolution this is to big. I have to change it and make a re-login. This is very time consuming and annoyin

  • Moved Library to External HD but no Library Displays in iTunes

    I followed the procedure to move my library to the external hard drive. That is, I went to edit, then preferences, then went to the advanced tab and selected f:/ as the new iTunes music folder. Then I went to file, then library and selected consolida

  • Help! an icon i've never had before

    Tried updating and restoring my 15 gig iPod with dock connector tonight. Now my computer won't even recognize it. Gone through the entire support manual, and everything I've tried doesn't work. I do get this strange logo when I try the reset though: