UOM - Not maintained in language EN

Dear gurus,
I have created one UOM, which is not availabel in SAP. I used the same for my MIC and did the results entry and UD.I didnot face any problem. But When iam trying to upload inspection plans thru LSMW with the same MIC, system is throwing a message UOM is not maintained in EN language. Pls guide me what  to do.
Thanks and regards
Venkat . V

Venkat,
First, you should logon in EN to the system and create the unit, otherweise you will get this error.
Second, do settings here:
Go to CUNI --> Go to --> translation -->unit of measurement --> Here define your langauage...
Here select EN to EN
Hope it solves your problem....
Thanks!!!

Similar Messages

  • PC UNIT NOT MAINTAINED IN LANGUAGE EN.

    Hi,
          I am doing extraction using LIS and when i do initial fill of set up tables using t code oli3 it is saying PC UNIT NOT MAINTAINED IN LANGUAGE EN.
    PLEASE TELL ME WHAT NEEDS TO BE DONE .

    Hi
    If I got your question properly, you need to run the Unit conversions for the UOM try at RSUOM or try with table
    T006 at se11.
    If you go to the domain MEINS of this data element there is conversion routine CUNIT . In this there are 2 function modules CONVERSION_EXIT_CUNIT_INPUT and CONVERSION_EXIT_CUNIT_OUTPUT . This converts PC into ST and then ST into PC . This function module you can test in SE37 .
    Hope it helps and clear

  • IW32: Error getting message (Text for order header not maintain in lang.EN

    Hello All,
    We just starting getting this message in IW32 and IW33 stating (Text for order header not maintained in language EN) then all the pre-existing description test disappeared.
    We have not done any configuration change in this particular system.
    Can anyone help to resolve this.
    Thanks

    Hi,
    As with most SAP messages it is always a good idea to trust what it is saying.
    The system is telling you that KG has not been created in the English language.
    Go to transaction CUNI to check the settings.
    Select the Unit of measure for "MASS" (from the drop down list) and check the entries for UOMs.
    KG should be there and should have an English description (the message said it was not there for EN)
    If it is there and set up correctly then there might have been something else in the UOM field? You didn't enter " KG" did you (a blank character then  KG?)
    Steve B

  • No short text maintained in language ZH (please re-maintain material)

    Hi,
    I was trying to create a PO for the material that I have created, however, system prompted that "no short text maintained in language ZH (please re-maintain material" error. Please advise us on how to resolve the error.

    Dear Jacqline,
    This message is because you have not maintain the  language ZH in material master
    Step 1: Go to Tr. code: MM02, enter your material and select few Views and inter
    Step 2: Click the Additional data  field top above
    step 3: Maintail the language ZH and material desciption and save it
    Youe Query will resolve

  • Error: In language EN, the internal unit of measure DA is not maintained.

    hi
    i am doing subcontracting operation and when i try to convert the PR into p.o in co02 the system gives this error
    In language EN, the internal unit of measure DA is not maintained.
    how can i solve this error...

    Hi,
    There are couple of things..
    1. PR to PO Creation is not with T.Code: CO02.
    2. It seems you are working on Multi Global environment.
    Ask your Basis Team to do the Language imports for UOM.
    Regards,
    Siva

  • Internal unit GAL, language EN is not maintained

    Hi All,
             i am facing problem with "Internal unit GAL, language EN is not maintained
    Message no. BM302" error while running the report...some one gave solution for this problem..still i am getting same problem ....please any one give explaination about that error why it is coming like that and also solution?
    Regards,
    surendra.

    hi..
         i  check it in that Tcode (S_BCE_68000183 or CUNI )..but it is not there..what can i do now?can any one explain about that problem? it means why it is coming like that?

  • BDC error BM302 : Internal unit &, language & is not maintained

    Hi Experts,
    I have Unit of measurements defined as below in T006A Tables ( Configured through CUNI tcode)
    SPRAS MSEHI MSEH3 MSEH6  MSEHT      MSEHL
    EN        UNT     UNT      UNT       UNIT         Unit
    HU        UNT     DRB      DRB      Darab      Darab
    Through BDC Prpgram  i have created an inforecord ( using ME11 transaction ), where Logon Language = HU. It is created successfully. When i try to open the created info record using ME12, the unit ( EINA-LMEIN) is displayed as '**' and it throws message "Internal unit DRB, language HU is not maintained ". When i Checked in database EINA-LMEIN is saved as '**'.
    But when i create the Info record manually in ME11,  No issues .The database EINA-LMEIN is correctly saved as 'UNT'.  
    I couldn't figure out the issue , whether problem is  in my BDC program or Language dependent configuration of the unit in CUNI. Please help in solving this issue , Am i  missing something ?
    Thanks in advance.
    Regards,
    Murali

    Hi Murali,
    You might be missing some more configuration (T table entries). To determine what that is -
    Process the info-record using ME12
    Start debugging "/h"
    Once debugging starts - place Breakpoint At MESSAGE statement
    F8
    Program control will stop at every message triggered and one of them would be you message. Check the code around the message (and call stack if required) and you might see the reason for the error
    Cheers,
    Aditya

  • Language field is not maintained in the source system

    hi,
    I had problem with 0ehs_actn_text data source. when i'm trying to pull data to BW it's saying language field is not maintained in the source system.
    I check the datasource there is no language field in the extract structure. and No fileds are checked for slection. I found one field REFOBJ checked in the data selection tab of datasource. But the data not coming to BW side. 
    could anyone help.
    regards
    kumar

    hi kumar,
    Check in rsa6 TXTLG field should be there and it should not be checked in  HideField Tab.. then only the data will populate to BW..
    So make the things properly and once again replicate the data source in Bw side.. load the data..
    other wise if u dont wanto the language field in Bw side goto infoobject maintanance uncheck the "TExt Language dependent" option in masterdata/texts Tab.. save and activate it.. load the data..
    i hope this will help you..
    Thanks..
    ravi.p

  • Internal unit HA, language EN is not maintained

    HI,
    I got this error message, what should i do?
    Cheers,
    Nies

    Hi
    Refer  Note 431031 - Internal unit PC, language EN is not maintained.
    It can guide you a bit.
    Regards

  • Internal unit NO, language EN is not maintained

    Dear sir 
          When i am uploading material using  BAPI for MM01 . i am facing the following error...
    Internal unit NO, language EN is not maintained....
    So pls guide me...
    Thanks,
    Meena

    its means that the unit(base measure of unit) 'NO' not maintained in the system.
    check your BUM, it might be wrong entry or you need to maintain the BUM as 'NO' in your system.

  • Language field not maintained in the source system

    hi,
    I had problem with 0ehs_actn_text data source. when i'm trying to pull data to BW it's saying language field is not maintained in the source system.
    I check the datasource there is no language field in the extract structure. and No fileds are checked for slection. I found one field REFOBJ checked in the data selection tab of datasource. But the data not coming to BW side.
    could anyone help.
    regards
    kumar
    Message was edited by: S Kumar

    hi kumar,
    Check in rsa6 TXTLG field should be there and it should not be checked in HideField Tab.. then only the data will populate to BW..
    So make the things properly and once again replicate the data source in Bw side.. load the data..
    other wise if u dont wanto the language field in Bw side goto infoobject maintanance uncheck the "TExt Language dependent" option in masterdata/texts Tab.. save and activate it.. load the data..
    i hope this will help you..
    Thanks..
    ravi.p

  • Error '' Unit IN2 is not created in language EN"

    Hi all, I have created new material using UoM as "2 (square Inch), when i am doing excise Invoice for the same material it is ginving me error that '' Unit IN2 is not created in language EN"  while it is allowing me to do GRN without Exc Invoice.
    i have tried to CUNI , there is no entry showing for  unit of measurement for "2 or IN2 . i tried to maintained is is giving message
    'Unit of measure IN2 already exists'  if i checked table t006A it is showing the Enrty in EN & DE both language,
    i have also teried
    Goto --> translation --> unit of Measurement  but not sure what to do there, i have save confirm translation for the "2 there but still same problem is appearing.
    Please Guide  Any helpful ans will be awarded full marks. thanks

    In what language did you create this new unit?
    when you start CUNI, in the initial screen choose from menu GOTO > Translation  to translate your unit into english language.

  • Error as unit of measure PC not defined for language RO while creation ofPO

    Hi GUYS,
    When am trying to create a PO in ME21N transaction i got error as below,
    unit of measure PC not defined for language RU
    Message no. 06079
    Table 006A contains no entry for this unit of measure
    Please let me know what action to be taken from my side to over come this issue.
    Note: If i check the related vendor i could able to view that the language maintained as RU.
    Cheers,
    Kumar.S

    Hi Jurgen,
    Thanks for your reply once again.
    As mentioned by you earlier i have tried to login with languae RU in Q system but unfortunately i got an error saying taht language not installed.
    Also we found for Language - EN and UOM - PC has been maintianed in T006A table.But if i check for lanugage - RU and UOM PC combinatoin has not manintaned in T006A table.
    Please let me know how to maintain the values in this table T006A for combination Lang - RU and UOM - PC.
    Please revert back with your soilution.
    Note: I have tried in SM30 but failed due to below error
    The maintenance dialog for T006A is incomplete or not defined
    Cheers,
    Kumar.S

  • Unit *** is not created in language EN - POSDM in CAR 1.0

    Hi all,
    I am getting the error message "Unit *** is not created in language EN" (Message no. BM305), while creating POSDM transaction.
    I did set up and loaded data into BI components 0MATERIAL, 0PLANT, 0RPA_MEAN, 0MAT_PLANT & 0RPA_MARM.
    I have verified that tables T006 & T006A are having Unit of measure 'EA' with language English.
    When I used Tcode 'CUNI' and gave source and target language as EN. I am getting error message 'Could Not Save Target Text'. But this would not be an issue I guess, because I have verified a working system source/Target were not maintained there.
    Please let me know if any further setting to resolve the issue.
    Thanks,
    Venkatesan

    Thanks Vikrant for your reply.
    Actually I have used flat file upload, and ensured that the Infoobjects are mapped properly.
    When I use POSDM Workbench, I am getting error like 'Unit EA is not created in language EN'. T006/T006A are having UoM in language EN. Is any other common setting I am missing here?
    0RPA_MARM - has only attributes? Do I need to upload TEXT for this object?
    Thanks,
    Venkatesa

  • Unit of measure is not maintained at level2 DSO

    Hi Experts,
    Unit of Measure is not maintained in level2 DSO.
    Scenario:
    We have a Product having values for different market in DSO UOM is Millions and Aggregated Value of that product is loaded in upper level DSO Unit of Measure is not maintained it shows blank.
    Solution: We have done selective deletion and uploaded again from the DSO where UOM is maintained correctly, Issue is resolved.
    We would like to know the cause of the issue.
    Please any let me know how to isolate the issue and if you have time let me call you to investigate further.
    Regards,
    Prem

    Hi Murali,
    UOM is maintained in level1 DSO correctly and for certain aggregated values it is not maintained and this very strange if we do manual upload data UOM is correct in Level2 DSO.
    I guess issue happening in regular data load or what so ever....
    We are trying to correct the data just by deleting and uploading again as this is permanent solution.
    If routines are the issue when we upload manually it shouldnt work but still working fine... this strange behaviour....
    please suggest and advise me... if required let me call you.
    Regards,
    Prem

Maybe you are looking for