Uploading infocube without Delta-Upload method

Hi!!!
I’m new in BW. I have 2 infocube that don’t have the function of Delta-Upload. I had loaded data to these cubes in the method “Full update. How should I be doing the following extraction? Do I need to erase the previous data in the infocube (data loaded last time)? Does anyone have a manual about this? My email is [email protected]
Thanks a lot!
Victor

yeah you need to delete the data before you do other full load, as the cube has a additive feature unlike ODS with overwrite function.
there are two ways you can do that, you can use a function delivered in process chain - process types to delete the contents of data provider
or in the infopack, in the data provider tab, there is flag "delete entire content in data provider", just check the flag, whenever you schedule a load, the data would be deleted before the lastest load goes in.

Similar Messages

  • Delta Upload - InfoCube Then Full Upload ODS

    Hello,
    1. I upload a InfoCube in Delta Mode.
    2. I upload form this InfoCube to a ODS in Full Mode.
    Exemple :
    1. InfoCube (Upload in Delta Mode) :
    Request Order Operation WorkCenter  Values
    1       10    1         AAA         +10
    2       10    1         AAA         -10
    2       10    1         BBB         +20
    2. ODS (Upload from the cube above in Full Mode)
    Order(key) Operation(key) WorkCenter Values
    10         1              AAA        -10
    The last record upload in my ODS is the second of the Infocube. The data in my ODS are incorrects. I don't know if I need to use 0RECORDMODE.
    Thanks in advance for your help.
    Stéphane

    Hello Stephane,
    In your scenario, please do either one from following in order to update date correctly in ODS from infocube,
    1. Change the update type to an addition from an overwrite at ODS level.
    2. or use serialized V3 update at the r/3 side, so that R/3 system sends changed records in the same sequence as it was generated. Because you might be getting +20 first then -10 and ODS setting is kept overwrite. As a result, the ODS data are incorrect(-10).
    Hope it helps you.
    Thanks and Regards,
    ~Ketan Patel.

  • Init and delta uploads using process chain

    Hi,
        I have a scenario where for the first upload i use init upload for that i have an infopackage now for the subsequent uploads i.e delta upload i get the option for the same only once i have run the init upload.
           so the doubt is can i use a process chain defined to carry out the whole task?????
    Regards

    Hi Virat,
    AS init is a one time activity, so what you can do is.
    1> set the init in infopack and run the process chain.
    2> remove the infopack and then include a new infopack with delta option or change the existing infopack to delta option.
    3> schedule the infopack.
    whatever you are expecting is not possible.
    Hope I answered your question.
    THanks and Regards,
    Suneel

  • Delta upload for DB connect.

    hi all,
    i have a small querry- i have to load data in a cube every month. my data source is a SQL table.
    i will load data using DBCONNECT.
    do we have delta update option for DBCONNECT, because in my info package i can see only "Full upload" option.
    if delta upload is available, then how do i get this option in info package.
    thanks a lot.
    Regards,
    Shruti

    Hi Shruti,
    In infopackage, in the tab for data selection, we can see some fields for selection. On those fields - we can write an abap code (routine) which will have some logic to find the last update date and then populate the selection field based upon this last update date + 1. So the info package will dynamically fetch the required records.
    Regards,
    Amit Mittal.

  • Delta Upload for Flat File

    Hello Everyone
    i am srikanth. i would like to know wheather do we have a facility for Delta Upload for flat file. If yes can u please give me the steps.
    thanks in advance
    srikanth

    Hi Sabrina...thank you for ur help...i did load the data from cube to ods
    steps.
    1. i generated export data source on the cube
    2. i found the name of the cube with prefix 8<infocube name> in the infosource under DM application component.
    3. there are already communication structure and transfer rules activated but when i am creating update rules for the ods..i am getting the message 0recordmode missing in the infosource.
    4. so i went to infosource and added 0recordmode in communication structure and activated but the transfer rules in yellow colour..there was no object assigned to 0recordmode but still i activated.
    5.again i went to ods and created update rules and activated (tis time i didnt get any message about 0recordmode).
    6.i created infopackage and loaded.
    a)Now my question is without green signal in the transfer rule how data populated into the ods and in your answer you mentioned to create communication structure and transfer rules where in i didnt do anything.
    b) will i b facing any problem if i keep loading the data into the ods from cube (in yellow signal) ..is it a correct procedure..plz correct me..thanks in advance

  • Failure in Delta Upload

    friends,
           we have delta upload for our purchasing data to BW. from the infopackages the data is Updated to ODS- 0PUR_O01, which provides data to Infocubes - 0PUR_C08 and 0PUR_C07 and ODS 0PUR_O02 ( which in turn provides data to infocube - 0PUR_C09 ). 3 days back one request in ODS 0PUR_O01 went into error status. WAfter marking the request "RED" it was deleted from the ODS, but since the request had the same PSA_ID as that of an another successful (GREEN) request in the same ODS with data mart status ticked, this request also got deleted by mistake, as a result the datamart status for all the request in the ODS (0PUR_O01) is missing, from this time onwards the subsequent data updates to infocubes 0PUR_C08 and 0PUR_C07 and ODS 0PUR_O02 (also to Infocube 0PUR_C09 ) are finishing in Error status. we have deleted all the requests (after marking them "RED") for previous three days from the data targets ( infocubes 0PUR_C08, 0PUR_C07, and 0PUR_C09 and ODS 0PUR_O02). we also have deleted the correposnding requests from ODS 0PUR_O01 (after marking them "RED").Now when we are trying to reconstruct the requests at 0PUR_O01, it goes successful, but when we try to activate the requests into subsequent data targets ( back ground job BI_ODSA* ) the job fails with a short dump and the following error message.
    Error Message:-
    Check Load from InfoSource 80PUR_O01 , Packet Delta Package for Update by ODS 0PUR_O01
    Please execute the mail for additional information.
    Error message from the source system
    Diagnosis
    An error occurred in the source system.
    System response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.
    Procedure
    How you remove the error depends on the error message.
    Note
    If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the request.
    Short Dump:-
    What happened?
       The current application program detected a situation which really
       should not occur. Therefore, a termination with a short dump was
       triggered on purpose by the key word MESSAGE (type X).
    What can you do?
       Print out the error message (using the "Print" function)
       and make a note of the actions and input that caused the
       error.
       To resolve the problem, contact your SAP system administrator.
       You can use transaction ST22 (ABAP Dump Analysis) to view and administer
        termination messages, especially those beyond their normal deletion
       date.
       is especially useful if you want to keep a particular message.
    Error analysis
       Short text of error message:
       Request 0000017556 in ODS 0PUR_O02 must have QM status green before it i
       s activated
       Technical information about the message:
       Message classe...... "RSM1"
       Number.............. 110
       Variable 1.......... 0000017556
       Variable 2.......... "0PUR_O02"
       Variable 3.......... " "
       Variable 4.......... " "
       Variable 3.......... " "
       Variable 4.......... " "
    How to correct the error
       Probably the only way to eliminate the error is to correct the program.
       You may able to find an interim solution to the problem
       in the SAP note system. If you have access to the note system yourself,
       use the following search criteria:
       "MESSAGE_TYPE_X" C
       "SAPLRSATREE" or "LRSATREEF28"
       "RSATREE_START_ACTIVATION"
       If you cannot solve the problem yourself and you wish to send
       an error message to SAP, include the following documents:
    Please suggest a solution for this problem and to bring back the missing data mart statuses of the all the requests in ODS 0PUR_O01.

    hi olivier,
       the said request is in ODS 0PUR_O02. will try to explain the scenario:
    the data flow in this regard is:
    PSA ->          Infopackages                       -
    > *
              (2LIS_02_SGR, 2LIS_02_ITM  etc.)     
    *-----> ODS (OPUR_O01)  --> Infocube (OPUR_C07)
    *-----> ODS (OPUR_O01)  --> Infocube (OPUR_C08)
    *-----> ODS (OPUR_O01)  --> ODS (0PUR_O02) -
    > ***
    ----> Infocube (OPUR_C09)
    now when we try to reconstruct a request in ODS OPUR_O01, the a new request is created (Requid- 175429) with green status but without datamart icon. Now when this request is activated in 0PUR_O01 and since "Activate ODS object Data automatically and   Update Data Targets from ODS object automatically"  is checked in 0PUR_O01, new requests are created in ODS 0PUR_O02 (Requid- 17566)and infocubes  OPUR_C07(Requid- 17566) and OPUR_C08(Requid- 17566).  All these requests are with 0 data and PSA_ID are also 0. and then the above short dump and error comes in.. one thing to note here is
    "Activate ODS object Data automatically and   Update Data Targets from ODS object automatically" option is also checked in ODS 0PUR_O02.
    Hope this clears up everything..
    Edited by: Nivin Joseph Varkey on Jan 14, 2008 7:20 AM

  • Delta uploading job get cancelled in SAP R/3

    question, during delta loading from SAP R/3 to BW, if the delta uploading job get cancelled twice for some reason, will I lost some delta data??
    Pls advise!
    Many Thanks!
    rajatina.

    Hi,
    If your delta jobs are getting error out in BW then you don't need to worry about, because till that time your delta pointer in source system is not yet updated. But if you make any request green by chance in BW monitor then your delta pointer will get updated and you might loose some delta.
    You can request repeat delta multiple times without any issue.
    Regards,
    Durgesh.

  • Upload the data using sessoin method

    HI All,
      i have a flat file of 1000 records i uploaded 1000 records using session method but some records are missing.In error log i got some errors.then now how can i update the error records.

    You haven't provided much information.  What transaction?  What upload method? Custom program or standard?  You either need to process the transactions in foreground or errors only mode to fix them OR you need to fix the errors at the source and re-run them.  A good developer always programs for errors and reprocessing with prevention of duplicates, so that you could run the entire file again without issue.  Did you tag the records/documents with an identifier to prevent duplicates?

  • How to re-init a delta upload?

    Hi experts
    I have done a delta initialization, and delta updates; but after occurs some troubles and then I must do a full update. Now when i want do new deltas uploads, the system tell me that can't find the last "mark". Im try to do an "initialization with out transfer data", but the message is that already exist delta loads for the same period in the id request 25910 (this id is the first inicialization)
    How can I do a re-init delta upload?
    Thank you in advance

    Sorry, I think that I dont understand you well..
    Please check if this right: "I can delete the init with Id request 25910 (in the way that wou tell me) , and the data in this id requist NOT will be delete in the Infocube"  is this true?
    In need to the re-init because when I run the delta actualizations the error msg is "Nº RSBM103 - Delta upload is possible after successfull init"
    Anyway, I understand that when is do a full update i lost the mark. Is this true?
    Your commets are very helpful!!

  • LO Extraction - error in delta upload

    Hi,
    I try to do some delta upload. The delta initialization works fine. I run OLI8BW and created an InfoPackage for delta initialization.
    Now I have problems with the delta upload. I selected update method 'queued delta' in LBWE and run the job. If I try to start the loading via InfoPackage (delta upload) an error occurs. In RSA7 I can see the delta's, but there is nothing in LBWQ. The error message in the BW monitor is the following: 'Transfer structure field not contained in DataSource'. There is one field in Transfer structure, which isn't contained in data source, but I fill it via a routine. Any ideas what the problem could be?
    Thanks a lot.
    Gabi

    hi,
    check sap oss note
    881207
    Symptom
    You load data in Delta mode and the system issues error message R3 037 in the monitor:
    Transfer structure field not contained in DataSource.
    Note 868059 did not deliver a complete correction.
    In Delta requests or repeat requests that contain time-dependent selections, these time dependencies are always transferred to the source system with the 'DATETO' and 'DATEFROM' field names.
    Time selections are also transferred to the source system if the time-based fields are not known as selectable fields in the DataSource.
    Other terms
    Scheduler, Update tabstrip, repeat, DATETO, DATEFROM,
    Delta, Init, date selection, InfoPackage, selection, M, X, 1. R3 037
    Reason and Prerequisites
    The problem is caused by a program error.
    You have implemented Note 868059 as an advance correction or you have imported it using a Support Package.
    Solution
    BW 3.0B
               Import Support Package 29 for 3.0B (BW3. 0B Patch 29 or SAPKW30B29) into your BW system. The Support Package is available when Note 0783251 "SAPBWNews BW3.0B Support Package 29", which describes this Support Package in more detail, is released for customers.
    BW 3.10 Content
               Import Support Package 23 for 3.10 (BW3. 10 Patch 23 or SAPKW31023) into your BW system. The Support Package is available when Note 0783253 "SAPBWNews BW3.1 Content Support Package 23", which describes this Support Package in more detail, is released for customers.
    BW 3.50
               Import Support Package 15 for 3.5 (BW3.50 Patch 15 or SAPKW35015) into your BW system. The Support Package is available, when Note 0836440 "SAPBWNews BW Support Package 15 NetWeaver'04 Stack 15", which describes this Support Package in more detail, is released for customers.
    BW 7.0
               Import Support Package 05 for 7.0 (BW7.0 Patch 05 or SAPKW70005) into your BW system. The Support Package is available, when Note 0829625 "SAPBWNews BW 7.0 Support Package 05", which describes this Support Package in more detail, is released for customers.
    To provide advance information, the notes mentioned above may be available before the Support Package is released. In this case, the short text of the note still contains the words "Preliminary version".

  • Delta upload in different times and targets

    Dear BW Gurus,
    I have to fill a Master Data table with a delta (for performance reasons) from an ODS object, and later fill an InfoCube with the same delta from the same ODS Object. This two step approach is necessary because the Cube uses the Master Data filled in the first step - so I cannot do the two uploads within the same InfoPackage.
    My approach was the following in a Process Chain:
    1. Fill and activate "source ODS"
    2. Load request from "source ODS" to PSA only
    3. Update Material Master from PSA using "Read PSA and Update Data Target" process with the variant setting the PSA table and the Master Data InfoObject as Data Target.
    4. Run "Attribute Change" process for the Master Data IO
    5. Update InfoCube from the same PSA that was used for the Master Data InfoObject. This is also a "Read PSA and Update Data Target" process with the variant setting the same PSA table as before and now the InfoCube as the Data Target.
    To me this seemed logical but when I run the Process Chain I got the following error message at point 3 (update Master Data from PSA): "No request for posting found in the variant".
    This appears strange to me because if I specified the request, it would only work for the first upload and not for all the others.
    Can anyone please help me how to overcome this issue of Delta upload in different times and targets?
    Thanks in advance,
    Attila

    Gopi,
    If I create two delta InfoPackages, the first one clears the delta queue, so the second InfoPackage won't find any data. This is unfortunately not the way to do...
    Srini,
    Your proposal is quite original - if I upload the same ODS with its data (amended by the date field) that would in fact generate a new delta for the same ODS.
    However, in the meantime a more simple idea came up in our BW team, inspired by your proposal. For the uploading of the Master Data I now don't use the delta functionality of the ODS export Data Source, but instead I set up a full upload filtered for the actual date. This ensures the good performance of Master Data load (load time will not increase with time) and also we will have all recent Master Data uploaded from the ODS because that load is in the same Process Chain where the "Source ODS" is updated. Later in the same Process Chain I simply start the delta upload for the Cube.
    Thanks a lot for all your help.
    Attila
    P.s. I will be out of office for until 24th July.

  • Delta upload uploads no data - CRITICAL

    Hi experts,
    This is really urgent because it affects a production system.
    I have got an infocube that is regularly uploaded with both full and delta uploads. Last friday we installed some patches and since then has been impossible to upload in delta mode but just for one DataSource (infosource). The result is no data records loaded but the monitor request is in green and shows as if there would be 'a lot' of records uploaded to the infocube.
    I have deleted the upload requests, and also the delta init, and I have tried uploading again as delta from scratch.
    I have tried to delete connection between the infosource and the datasource (R/3), reestablish it again and initialize and start delta upload.
    I have tried to create a new infocube mirroring the original, and then create EVERYTHING (infosource link to the datasource, update rules, etc).
    I have also tried a full update instead of a delta update, and the result is same as always: no data loaded but request in green.
    A curious detail: when I created a new infosource and assigned to the datasource, then the system shows a message as this datasource already have a delta init for the previous infocube; even when I already have deleted as the delta init as all the upload requests (????).
    For me it sounds as the delta is corrupted, I am wrong?
    How can I solve this? I really need urgent help
    Thanks in advance

    Hi,
    Before applying any patches in R/3 side we have to move all the delta data to BW to Clear the entries in LBWQ,SM13 nad RSA7.
    Refer the note for further information: 328181
    I think, you have no further options rather than starting Delta init.
    With rgds,
    Anil Kumar Sharma .P

  • Delta Upload for Customized DataSource

    Hello,
    I created a Customized DataSource with Full Upload and replicated DS in BW ,now i want to creat Dalta Upload for the same Data Source is it possible can i do ,is there any method or settings to be done to get Delta upload  update..
    I hope my thread is understandable....
    ifnot get back ....!
    Thanks

    Hi Bhanu,
    What is the Safety Upper & Lower limits you have given for your Generic Delta(RSO2 trans). That also matters.
    Give Safety Upper limit as 0 & Lower Limit as 1, Replicate the DS once in BW & then try to load Delta.
    If possible Delete the Init--> Load the Init again & then try loading Delta after changing the Safety limits & loading INIT.
    Hope it helps you!
    Regards,
    Pavan

  • Is it possible to run delta upload in both servers simultaneously?

    Dear SAP gurus,
    We already have a running BW server version 3.0 B,Now we are planning to use another server having BI 7.0.Both thease servers needs to extract data from a single R/3 server.We have delta upload for some master info objects,Is it possible to run delta upload in both servers simultaneously?
    If so,pls. let me know how to implement the same.
    Regards,
    Anuradha

    HI
    As said in the previous post u can run the delta in both the systems. Follow the same procedure how u do while u create a new infrastructure and do init without data transfer and do the delta loads.
    correct me if i am wrong
    Khaja

  • Can a write-optimized DSO be used for Delta upload

    Hi,
    can any one please answer following..
    1. can a write optimized DSO be used for Delta upload?
    2. Does industry based content is available in BI Content ?
    Thanks&Regards
    Satya

    Hi,
    Write-Optimized DataStore does not support the image based delta, it supports request level delta, and you will get brand new delta request for each data load.
    Since write-optimized DataStore objects do not have a change log, the system does not create delta (in the sense of a before image and an after image). When you update data into the connected InfoProviders, the system only updates the requests that have not yet been posted.
    Write-Optimized Data Store supports request level delta. In order to capture before and after image delta, you must have to post latest request into further targets like Standard DataStore or Infocubes.

Maybe you are looking for

  • I have an unknown shared server in Finder. What is it and how can I get rid of it?

    Hi, I just noticed there is a shared server/ network listed in Finder, but I do not recognise it and cannot connect to it. Could anybody tell me what it is and how I can remove it? Thanks! This is what it looks like:

  • Delete cost element o reconcile FI-CO

    Hi guru, I have the following problem. I have posted a document in november with a G/L account that I haven't created cost element. I have created the cost element in december and, succesively, posting another document. Now, I can't delete the cost e

  • Load Balancing with BigIP / SSL question

    I have an oddball question. We're load balancing ColdFusion MX7 across 3 servers using a BigIP load balancing server. We decided to go the hardware approach and it has been great except for one small configuration issue. We use a mix of SSL and non S

  • E71 + BH-602

    Hi, We recently purchased two E71's with BH-602 bluetooth headsets. The devices pair OK, but it's not possible to answer calls with the answer/end button on the headset. Same problem on both sets. If I answer the call on the phone I can continue the

  • Adobe reader 10.1.2 under vista home premium 32-bit enters 'save as ...' rather than print

    Reader X 10.1.2 (reloaded in response to some fix which was offered, 10 Feb 2012) will not print (either using the printer icon or "file print ...". Instead, it goes into the "save as " menu. I tried to reload Reader (just got "program already loaded