Urgent Help! Errors in source system(RSM     340)

Need urgent help. Issue in production.
I added fields to the COPA datasource, by changing the operating concern. I recreated the datasource with the same name replicated into BW & ran delta again. The whole procedure worked fine in Dev & Quality but in production it gives me the below error. I thought its a delta issue so I deleted the data & try reload but still same issue. Below is the error. I checked the connection with R3. its an ok. All other loads work fine. Before deleting delta, it gives below error & when you rerun, it finishes with zero records. I also tried activating update, transfer & ods & cube in BW. I also asked functional guy to check operating concern & its active. kindly help
Errors in source system     RSM     340
Error message from the source system
Diagnosis
An error occurred in the source system.
System Response
Caller 09 contains an error message.

Hi PK,
caller 09 error mainly because of source(target system) and destination(bw system) not configured correctly.
i think you get the error message as follows. file is in the client workstation as like.
better you contact basis people. they will resolve this.
hope this help you
Regards
Harikrishna N

Similar Messages

  • CO-PA Delta load - Errors in source system RSM 340

    Hi,
    We are facing a unique error when we do a CO-PA delta load. The error message is as follows:
    "Errors in source system RSM 340,The selected data source is locked by another process RD 156"
    The load completes successfully with 0 delta records fetched. When we re - trigger this after sometime, the load goes through.
    Can anyone explain as to why this issue occurs ? Basically, looking at the root cause.
    We are pulling data from CE1XXXX table, the delta for which is pulled into BW with the setting of 30 minutes safety delta. Just wanted to understand how is it that in this scenario we are faced with a lock issue ? It is also confirmed that while the delta load is initiated the transactions are being passed into the CE1XXXX table.
    Thanks,
    Amit Mitra

    Hi PK,
    caller 09 error mainly because of source(target system) and destination(bw system) not configured correctly.
    i think you get the error message as follows. file is in the client workstation as like.
    better you contact basis people. they will resolve this.
    hope this help you
    Regards
    Harikrishna N

  • Error in the Data Selection - Errors in Source System RSM 340

    Hey Everyone,
    I'm having an issue with loading a Delta for 0MAT_PLANT_ATTR.  This is the second night it has happened, where I get the error "Error in the Data Selection".  This error happens in the EXTRACTION part of the Monitor.  And, we cannot run another Delta to see if it'll work, we have to delete the old Delta Init, and run a new one.  The other error is "Errors in Source System - RSM340".  That's as much it gives.
    Could anyone suggest why this would be happening?  I checked RSA3 in R/3, and no errors on the extraction.  I also checked sm37 against the job that loads that data, and it completed successfully.  I honestly don't think there's an issue with the data.  We cannot have this happen often, and I just need to know if this is something that can be corrected.
    Thanks,
    John

    There is nothing wrong with the TID's or anything like that.  There is also no selection criteria in the infopackage.
    When the Delta fails, the error occurs under EXTRACTION in the monitor.  It seems to be successful under TRANSFER and PROCESSING in the monitor, which I find strange.  Also, I run a new Delta Init with Data Transfer, and that works just fine.
    So, I'm not sure what it could be?

  • Errors in source system

    Hi  Friends,
                      I got an failure with a data load... The data was loading into ODS from r/3. The data source name 2lis_03_bf... I got an error like this in status Tab -
    <b>Error message from the source system</b>
    <b>Diagnosis</b>
    An error occurred in the source system.
    <b>System response</b>
    An error occurred in Extractor .
    Check the error message.
    Procedure
    The procedure for removing errors takes place depending on
    <b>the error message:</b>
    Note
    If the source system is a Client Workstation, then it is possible that the file that was to be loaded was being edited at the time of the data request. Make sure that the file is in the specified directory and is not being edited, and restart the request.
    And when we click on the error message push button... we are having the following errors : -
    <u><b>Message Type </b></u>    <u><b>Message Class</b></u>   <u><b>Message Class </b></u>
    Errors in source system                                             RSM         340
    Queue 2LIS_03_BF is not available in the source system      RSQU         9
    Activation of data records from ODS object terminated             RSM1       102     
    Answering Getz appreciated,
    Thanks & Regardz,
    <i><b>Aluri</b></i>

    Hi,
    On BW go to SE16. Look at RSSDLINIT table. Match up the LOGSYS with your OLTPSOURCE (for the infopackage that is causing the problem).
    Delete that line
    Now you can open the infopackage. (be sure to delete the initialization) before you run the info pack again.)
    Regards
    Srini

  • CRM Init load failure Errors In Source System 340

    Hello
    This is my first question on SDN.........could anyone help me please????
    When I am attempting to do an Init load to ODS 0CRM_PROH and to MD Infoprovider 0CRM_SRVGUI, using Infosource 0CRM_SERVICE_PROCESS_H the load is failing and I get the message Errors In Source System 340.
    Version is BW3.5 and CRM4.0
    Thanks
    Emma

    Thanks Venkat
    I have considered this but could you please explain the following:
    If I start a full load at say 10am.  It finishes at 11am.  If I then do an init no data at 11.05am after the full load has finished.  then I do a delta.  Does this mean that my delta will pick up data only from when the init no data was done and set the timestamp?
    So I will lose any data between 10am (when I started full load) and 11.05am (when I ran init no data)?
    Emma

  • Error in source system in BI 7.0...

    Hi,
         When creating a source system in Bi 7.0, when i am going to t code- rsa1- client-right click and then check,it's giving an error like:
    EDI-  partner profile not available and then detail for this error is-- a partner profile cannot be found with this key- /DBICLNT300/LS
    THIS INVLOVES THE KEY FIELD OF THE TABLE EDPP1-
    PARNUM-PARTNER NUMBER
    PARTYP-PARTNER TYPE
    Please help me in solving this. Thank You.

    Hello,
    Try a restore on your source system (rightclick -> restore) This way idoc ports and agreements are regenerated between BW and R/3. If this does not solve the problem ceck this:
    Hi,
    Did you do a system copy for BW ?
    Try a restore (rightclick on your source system) in most cases this will solve the problem.
    If not check the notes below:
    184322 Procedure after DB copy of BW source systems
    886102 System Landscape Copy for SAP BW 2.X, 3.X and NW2004s BI
    325470 Activities after client copy in BW source systems
    325525 Copying and renaming systems in a BW environment
    184754 Procedure after BW database copy
    184447 Building a BW-system landscape
    184971 Notes on BW source system connections
    140276 Error in source system assignment
    524554 Storing destinations in the BW environment
    538052 Maintenance of Myself destination in BW
    Regards, Patrick Rieken

  • Error in source system TD1511

    hello gurus, I have a Infosource name 2LIS_05_QE2, I haved assigned 4 Source System namely (CD1513, GP1590, TD1511, WD1511), It uses a Function Module in R/3 and Appended Structure (I've already transported the FM, Appended DS, Function Group and the Zsextractor assignment), I don't have any problems in activating other Source System (CD1513, GP1590, WD1511) only in TD1511, I can't activate the Transfer Rule and Im getting the error,
    "Error in source system TD1511 "
    Ive already replicated the Source Ssytem and only in T Cluster Im currently experiencing the said problem, I even go to Source System and right click on the T Cluster to check,  and the connection is ok, What maybe the caused of the said problem? thank you very much... I really appreciate any help...

    Ive fixed it, Ive check all the R3 box 2 by 1, and T Cluster was down, by the way thanks, The Checking of connection in BW is so confusing because it says "OK", but when I check each cluster individually, I noticed it was down, Thank you very much,I will give you a score

  • Error deleting source system with error message: "incorrect input for....."

    Hi,
    I'm trying to delete the source system using tcode RSA1 => Source systems => select the 'source system' and delete, but I got an error message as follows:
    "incorrect input for activating transported shadow IPacks"
    Fyi, I have opened up the client configuration (SCC4) prior to delete this source system but the source system still cannot be deleted and I receive the above error message.
    Please let me know what is the caused of the error and how to solve the problem.
    Thanks for your kind help.
    Regards,
    Mark

    Hi Mark,
    Which version of BW are you in?
    check this thread and also the note 709581
    Error Deleting Source system connection
    Thanks,
    Raj

  • Get Error in source system when loading flatfile from application server

    Hi
    I'm loading data from flatfiles on the application server. In the datasource if I display the sample data. It shows fine.
    But when I execute the infopackage I get an error when it is loading the data to PSA.
    The error is
    Error in source system
    Message no. RSM340
    There is no further information
    But if I load from my machine it works fine.
    Any help will be great

    Hi,
    As you can view display the sample data. It shows fine.
    It mean there is no issues in BW (File path is correct, Data in Flat file is correct).
    Then definetely its with the source system, which is resisting to pass IDOC to BW.
    Now.we need to know the its problem with File on App serv or App serv itself?
    Just check trying to Load another  Flatfile in App serv.
    Let me know.
    Regards
    Hari

  • Delta Loads failling after system copy with error in source system(RSM340)

    Hi Guru's
    We recently performed system copy in BI side.I am facing same issue in couple of chains.Process chains are failing at delta loads with error in source system(ERROR IN SOURCE SYSTEM-message no-RSM340 ).When I go for repeat option ,delta loads are running fine.I did some research regarding RSM340 and I found note:1576331.
    But my system is not showing any 'Time Inconsistencies'.So.I was not able to find any clue about it.
    Could anybody help  me out in this aspect.
    Thanks!!!
    Kuldeep

    Hi,
    Check whether the profiles that ran in background have the following authorizations.
      The RFC user on BW, receiving data from OLTP system, should have  S_BI-WHM_RFC and S_RS_ALL in the user profile.
    The RFC user on OLTP, receiving request from BW system, should have  S_BI-WX_RFC, S_IDOC_ALL, and, B_ALE_ALL in the user profile.
    Regards .

  • Error in source system while extracting the data from R/3!

    Hi,
    i had created FM and extract strcucture in R/3 .
    using the above two, i had created data source using RSO2 T code.
    when i checked the extractor ( RSA3 T code) in R/3  it was working fine .
    (status messege displayed as 1000 records selected).
    then i assigned  this data source to infocurce and creted info cube using the same info source.
    but when i schedule the info package it is syaing in the monitor screen "error in source system".
    what could be the problem?
    Thanks,
    Ravi

    Hi
    trhese are the possiblies
    1.first check the source system connection and find if there is any error in it.
    2.Go to sm37 and find whether the  request is completed or not if its terminated find out the time. how long does it takes to complete the process.
    3.once again relicate the data source and find whether is it again extract data.

  • "Error in source system" while creating source system

    Hello,
    I don't know what's our general problem (I suppose that it's ageneral problem) but we always have the following eror while creating a source system:
    When we want to create a source system on BI, we first get an error "No connection to source system possible". After checking the RFC connection and correct the password of the remote user on the automatically created _DIALOG RFC connection the exception changes to "Error in source system".
    The error occurs after the information "Please log on as an administrator in the following screen".
    The remote user on R/3 side has got profiles S_BI-WHM_RFC and S_BI-WX_RFC (found two conflicting statements regarding this profiles), on BI side it has got SAP_ALL and some more profiles
    What else could be the problem?
    Greetings & Thanks
    Bettina

    Hello,
    now we know that
    1. the remote user needs profiles SAP_ALL and SAP_NEW and has to be dialog user with a password unequal that password it should have in the future (otherwise you don't see the error messages that appear during the login process)
    2. the system has to be changeable (scc4 and se03)
    After the source system is created the changeability can be changed to the original values and the remote user can be changed to a communication user again.
    Thanks for the tip regarding the authorizations.
    Greetings
    Bettina

  • Error in Source System While Uploading Data from ODS to Data Target

    Hi All,
    Iam getting Following Error while Uploading data from ODS to Data Target
    a) Error in Source System.
    b)DataSource 80MKT_DS01 has to be replicated (time stamp, see long text)
    Message no. R3016
    Diagnosis
    DataSource 80MKT_DS01 does not have the status of the source system in the Business Information Warehouse.
    The time stamp in the source system is 21.06.2005 07:31:33.
    The time stamp in the BW system is 27.11.2004 17:41:45.
    Regards,
    Chakri

    This generally occurs when you change the data source or enhance the data source or the coonections to the datasoiurse are broken. To resdolve thius sort of errors just
    1. Check for the coonect between the sourse & target systems
    2 . Replicate the data sourcses.
    3. Acivated TR,UR,& the rest of the flow But check in the source system if the structre is modified & is so do the changes in the IS , TR,UR correspondingly & the try to load .Hoppe it allows you to load .
    Thanks ,
    PSG

  • While loading data from r/3 to bw error 8 /error in source system is coming

    while loading data from r/3 to bw error 8 /error in source system is coming . how can i solve this problem .

    Check source system connectivity.
    Tcode RSA1 --> Source System RClick --> 'Check'

  • Error in Source System, Time series does not exist

    Hi Guys,
    I am loading the data from APO system and i am getting the below error after scheduling the info Packs.. can you analyze and let me know your suggestions
    Error Message : Time series does not exist,
    Error in Source System
    I have pasted the ststus message below
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.
    Procedure
    How you remove the error depends on the error message.
    Note
    If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the request.
    Thanks,
    YJ

    Hi,
    You better search for the notes with the message ""Time series does not exist". You will get nearly 18 notes. Go through each note and see the relevence to your problem and do the needful as it is mentioned in the note .
    Few notes are:
    528028,542946,367951,391403,362386.
    With rgds,
    Anil Kumar Sharma .P

Maybe you are looking for

  • REQUIREMENT TO POPULATE PLANNER GROUP in REPAIR SERVICE ORDER

         Hi Gurus,     We are using Standard repair process, These are the Following Steps 1.Service Notification Creation. 2.Sale order Creation (RAS order type) 3.Returns Delivary 4.Posts Goods Receipt 5.Repair Service Order created in the Backend.    

  • Target Disc Mode via Firewire PC Card

    I am unable to boot my PowerBook Ti in firewire disc mode as my firewire port died. Since i've been using a PC card with 3 firewire ports on it. When attempting to reboot in firewire disc mode with another mac it just restarts. I surmise the issue li

  • Linking combo boxes to a table

    I have made a set of combo boxes that allow the user to input a home and away football team and their scores. I have also setup a table with 4 teams in it. How can i link the combo boxes so that EG: If Arsenal 2 - 1 Chelsea is a result inputted how c

  • QM configuration document

    Hi all, I'm new to SAP. I've some idea about the business processes in QM module. I am trying to go in-depth in this module. Please, can anyone send me the whole configuration document w.r.t to Quality Management (QM). This will help me in step-by-st

  • What do the grey dotted circles mean?

    Hi, I'm trying to add some cds I imported into my iTunes onto my phone but it won't let me. When I plug my phone in to sync I click on this iPhone and the songs I want are highlighted with this grey dotted circle?