Urgent: Reports: Skip the first screen

Hi experts,
   In report program iam calling another program screen. I just want to skip the first screen of the calling program and when i call this program i should directly go into the output screen. Iam using like this. So how should i skip the first screen.
Please do needful help.
if p_err_u = 'X'.
submit rsuniscan_final. "VIA SELECTION-SCREEN AND RETURN.
Regards.
AADI

Use in Submit
   [USING SELECTION-SET variant]
    [USING SELECTION-SETS OF PROGRAM prog]
    [WITH SELECTION-TABLE rspar]
Santhosh

Similar Messages

  • Can I execute a report and skip the first screen in CJE0

    I'm trying to call transaction CJE0 and skip the first screen. The report name I'm assigning to the PID REI appears in the screen field, but you have to click execute to continue to the report.
    Is there something I'm missing.
    Thanks
    Karen

    I've tried using the following code to run project reports without having to select the report name and exectue, but it is still leaving the user on the screen for CJE0 with the correct report name, but it's not skipping the screen and executing the report. Can you see what I'm doing wrong.
    Thank-you for your help
    Karen
    Code -
      data begin of bdcdata occurs 100.
             include structure bdcdata.
      data end of bdcdata.
      data begin of itab occurs 10.
             include structure bdcmsgcoll.
      data end of itab.
    data program like sy-repid.
    program = '11ERL1A'.
      bdcdata-program  = 'SAPMKCEE'.
      bdcdata-dynpro   = '0500'.
      bdcdata-dynbegin = 'X'.
      append bdcdata.  clear bdcdata.
      bdcdata-fnam     = 'RKB1D-REPID'.
      bdcdata-fval     = program.
      append bdcdata. clear bdcdata.
       call transaction 'CJE0' using bdcdata  mode 'N'
                               messages into itab.

  • When the user click on the request number it should skip the first screen o

    when the user click on the request number it should skip the first screen of REV track and show the rev track request number details. On click of u201CBacku201D button on this screen the output screen of the report should be displayed again.

    Hello Rohit,
                   What you can do is, when the User Clicks on any particular Request, you use the At Line-Selection Event. In that event, you can set the User Name to default "SY-UNAME" or any other user Name for the specific Request.
                 Again, if you want to check the Owner of the Request, you can use the Table E070 where you can Input the Request Number and get the Owner of the Request. Set the same in the User Name Field and Skip First Screen (SE09 Transaction).
    Hope it was helpful.
    Thanks and Regards,
    Venkat Phani Prasad Konduri

  • Calling a transaction and skipping the first screen

    Dear forumers,
    In my report program, I will need to call a custom transaction with skipping the first screen.
    And, this custom transaction is created from a query.
    Currently, the codes look like below:-
            SET PARAMETER ID: 'BUK' FIELD w_output-bukrs,
                              'AN1' FIELD w_output-anln1.
            CALL TRANSACTION 'ZCUSTQ' AND SKIP FIRST SCREEN.
    Everything works perfectly alright except for one thing: The first screen is not skipped. When the custom transaction is called, the first screen is still displayed to the user.
    Additionally, I also found out that the "SKIP FIRST SCREEN" does not work because the screen's next screen number is the same. This means the screen 1000's next screen is 1000 as well.
    (See notes in italics below)
    Does anyone have any ideas on how to resolve this? Please help.
    This addition suppresses the display of a screen of the initial dynpro of a called dialog transaction. The addition AND SKIP FIRST SCREEN suppresses the first screen under these prerequisites:
    For the initial dynpro, in the Screen Painter the own dynpro number must not be specified as the next screen number.
    All mandatory input fields of the initial dynpro must be filled completely and with the correct values by the SPA/GPA parameters
    If these prerequisites are met, that screen of the dynpro is displayed that is specified in the Screen Painter as the next dynpro of the initial dynpro.

    For Any Query , if you want to create the Transaction you need to use the Tcode START_REPORT
    in general it will skip the first Transaction codes selection screen , Not your query reports selection screen.
    I checked and verfied...
    Steps to verify the issue..
    1.Go to SE93 ,Now you will go for parametric transaction.
    2. give the Transaction as START_REPORT, there you will have option Skip Initial Screen. You uncheck that.
    3. Now give all information related to your query.
    and see the  effect
    call TRANSACTION 'YYTCODE  AND SKIP FIRST SCREEN.
    This will always trying to skip the First transaction's selection/initial screen , Not your Query selection screen.
    You also try to check and let me know.

  • How to skip the first screen in se38

    hi experts,
       I am struck up somewhere in getters and setters in field symbols.
    I am setting the file name field in se38 and trying to directly go to display mode of the program and i am doing that through  RS_SPOOL_ACCESS . I am not able to skip the first screen of se38 and go to diplay mode of the program.
    How can i do that. Skip first screen is not working.

    If all else fails,  partial BDC may be in order.
    report zrich_0003
           no standard page heading line-size 255.
    data:   bdcdata type table of bdcdata with header line.
    parameters: p_prog(30) type c.
    start-of-selection.
      perform bdc_dynpro      using 'SAPLWBABAP' '0100'.
      perform bdc_field       using 'BDC_CURSOR'
                                    'RS38M-PROGRAMM'.
      perform bdc_field       using 'BDC_OKCODE'
                                    '=SHOP'.
      perform bdc_field       using 'RS38M-PROGRAMM'
                             p_prog.
      perform bdc_field       using 'RS38M-FUNC_EDIT'
                                    'X'.
      call transaction 'SE38' using bdcdata mode 'E'.
    *        Start new screen                                              *
    form bdc_dynpro using program dynpro.
      clear bdcdata.
      bdcdata-program  = program.
      bdcdata-dynpro   = dynpro.
      bdcdata-dynbegin = 'X'.
      append bdcdata.
    endform.
    *        Insert field                                                  *
    form bdc_field using fnam fval.
      clear bdcdata.
      bdcdata-fnam = fnam.
      bdcdata-fval = fval.
      append bdcdata.
    endform.
    Regards,
    Rich Heilman

  • CALL transaction using itab aswell as skip the first screen

    Hi All,
    I am doin BDC for some Ztransaction and i am that transaction using CALL TRANSACTION... but i want to skip the first screen of the Ztransaction as well as pass the Itab .. mode .. update and message table.... how can i do it...
    CALL TRANSACTION Z... USING iTAB UPDATE DATE MODE A  message bdcmsgcoll AND skip THE FIST SCREEN.. how to acheive it....

    PERFORM BDC_DYNPRO      TABLES BDCDATA
                           USING 'SAPLBPT1' '0100'.
    *PERFORM BDC_FIELD       TABLES BDCDATA
                           USING 'BDC_CURSOR'
                                 'BCONTD-BPCONTACT'.
    *PERFORM BDC_FIELD       TABLES BDCDATA
                           USING 'BDC_OKCODE'
                                 '/00'.
    *PERFORM BDC_FIELD       TABLES BDCDATA
                           USING 'BCONTD-BPCONTACT'
                                  V_CONTRACT.
    the above code /recording call the first screen 100 which i dont want...
    below code / recording is for screen 200 which i want to appear directly when i call the transaction....
    skipping the first screen 100..
    PERFORM BDC_DYNPRO      TABLES BDCDATA
                            USING 'SAPLBPT1' '0200'.
    PERFORM BDC_FIELD       TABLES BDCDATA
                            USING 'BDC_OKCODE'
                                  '=SAVE'
    PERFORM BDC_FIELD       TABLES BDCDATA
                            USING 'BCONTD-PARTNER'
                                   V_GPART.
    PERFORM BDC_FIELD       TABLES BDCDATA
                            USING 'BCONTD-ADDINFO'
                                   V_ZONE.         "ZONE(S,N,E,E,NE)
    PERFORM BDC_FIELD       TABLES BDCDATA
                            USING 'BDC_CURSOR'
                                  'EENO_DYNP-ZEILE(01)'.
    PERFORM BDC_FIELD       TABLES BDCDATA
                             USING 'EENO_DYNP-ZEILE(01)'
                                   V_LOG.                 "MESSAGE
    CALL TRANSACTION 'BCT1'    USING BDCDATA
                               MODE MODE UPDATE UPDATE
                               MESSAGES INTO IT_BDCMSGCOLL.

  • Can we skip the first screen after call transaction has been performed?

    Hello Friends,
    I have written a program for INTERCATIVE REPORT .
    When i click on the link it needs to call transcation MD4C.
    I have written a BDC for calling the transaction and skipped first screen.Its working fine but the problem is that WHEN I TRY TO COME BACK TO MY REPORT OUTPUT USING(BACK OR EXIT OR CANCEL) BUTTONS THE CONTROL IS PASSING THRU THE FIRST SCREEN OF TRANSACTION MD4C and then its coming back to report output.
    Now i dont need the first screen of the MD4C to be dispalyed when i use the BUTTONS.
    That means i want to dirctly come to report output when i click (BACK OR EXIT OR CANCEL) BUTTONS.
    Hope the problem is clear.
    Is there any way?
    Please do suggest me.
    Thankx in advance,
    Sanghamitra.

    Hello everybody,
    Thanks a lot for the quick replies.
    The problem i m facing comes after the call transaction statement gets executed.
    when the statement gets executed i m able to skip first screen and goto the required screen in the transaction but WHEN I PRESS BACK BUTTON THERE it is showing the initial screen which i have skipped.I dont want this scrren to be dispalyed.When i press back it should directly take me to the report output from where i have come to this transaction.
    Hope i m clear now?
    Any suggestions.
    Regards,
    Sanghamitra.

  • TS1424 iTunes skip the first two songs of the album I just purchased from the iTunes Store?

    Why does iTunes skip the first two songs of the album I just purchased from the iTunes Store?
    I previously checked that the download was complete.  (Had plenty of time, but checked nonetheless it was done.)  I have closed and reopened iTunes several times.  Frustrated.

    If your country's iTunes Store allows you to redownload purchased tracks, I'd delete your current copies of the dodgy tracks and try redownloading fresh copies. For instructions, see the following document:
    Downloading past purchases from the App Store, iBookstore, and iTunes Store
    Otherwise, I'd report the problem to the iTunes Store.
    Log in to the Store. Click on "Account" in your Quick Links. When you're in your Account information screen, go down to Purchase History and click "See all".
    Find the items that are not playing properly. If you can't see "Report a Problem" next to the items, click the "Report a problem" button. Now click the "Report a Problem" links next to the items.

  • Skip the selection screen using BDCTAB call transaction

    Hi experts,
    I am using BDCTAB for call transaction SWI1 I need to skip the selection screen. Can you please tell me how to skip the selection screen using BDC call transaction?
    Thank you in advance.....

    hi,
    the first step is to pass some values to the selection screen, at least Date From and Date To; otherwise, it´ll take a long time. The second step is to emulate the Execute button, which is done with '/08'.
    PERFORM fields USING 'BDC_OKCODE'   '/08'.
    Third step is to catch the programme and screen number.

  • How to skip the PRINT screen?

    Hi All,
    I have a report, which calls the Smartform.
    When I execute my report, the PRINT screen will appear, where i press the PRINT button, and then the form gets printed.
    My requirement.
    I dont want this PRINT screen to appear. When i execute the report, the form must get printed, skipping the PRINT screen.
    Is there a way to do that?
    Thanks
    Krishna Kishor Kammaje

    Hi,
    See the blocked code.
    DATA: w_ctrlop TYPE ssfctrlop,
          w_compop TYPE ssfcompop,
          w_return TYPE ssfcrescl,
    Variables declarations
          v_form_name TYPE rs38l_fnam.
    call function 'SSF_FUNCTION_MODULE_NAME'
         exporting
              formname           = 'ZZZ_TEST2'
         importing
              fm_name            = v_form_name
         exceptions
              no_form            = 1
              no_function_module = 2
              others             = 3.
    IF sy-subrc <> 0.
      MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
              WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
    ENDIF.
    <b>w_ctrlop-getotf = 'X'.
    w_ctrlop-no_dialog = 'X'.
    w_compop-tdnoprev = 'X'.</b>
    CALL FUNCTION v_form_name
         EXPORTING
              control_parameters = w_ctrlop
              output_options     = w_compop
              user_settings      = 'X'
         IMPORTING
              job_output_info    = w_return
         EXCEPTIONS
              formatting_error   = 1
              internal_error     = 2
              send_error         = 3
              user_canceled      = 4
              OTHERS             = 5.
    IF sy-subrc <> 0.
      MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
      WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
    ENDIF.
    If your problem is solved,kindly reward points and close the thread.Otherwise,get back.

  • Cannot log in to Nationwide internet banking in Firefox. I get the front page but Login says internet banking is not working. Next screen says it's ok and sends you back to the first screen, which says it isn't. Works throughInternet explorer

    Question
    Cannot log in to Nationwide internet banking. I get the front page but Login says internet banking is not working. Next screen says it's ok and sends you back to the first screen, which says it isn't. Works throughInternet explorer

    That issue can be caused by corrupted cookies.
    *https://support.mozilla.org/kb/Cannot+log+in+to+websites
    Clear the cache and the cookies from sites that cause problems.
    "Clear the Cache":
    *Tools > Options > Advanced > Network > Offline Storage (Cache): "Clear Now"
    "Remove Cookies" from sites causing problems:
    *Tools > Options > Privacy > Cookies: "Show Cookies"

  • How to skip the first row in Text file (in Sql Loader)

    Hi All,
    How to say the control file to skip the first row of the text file..
    i just going this example
    this is my text file:
    01308201222455038130820122245503813082012224550382
    1090358 474661834012245503813082012 0075 0 00000000000 000000000 00000130820120000000000000000 136.84 -833.3911082012 000000 000 009035847466183 090358 47466183 0015007514300000970001430000097700BH1150274792012081320120811201208122012-08-11-22.45.50.38369899999.0075LIQJGL17
    Control file:
    OPTIONS
    DIRECT = TRUE ,
    PARALLEL = FALSE ,
    SKIP = 1,
    ERRORS = 0
    UNRECOVERABLE
    LOAD DATA
    INFILE      <"FILE_DIR">
    BADFILE <"FILE_DIR">
    INSERT
    INTO TABLE DAILY_TRANSACTION
    WHEN (1:1)='D'
    TRAILING NULLCOLS
    Above the Eaxmple text file i need to Skip the first row which is
    01308201222455038130820122245503813082012224550382
    please can anyone suggest me is this correct?
    if not please correct me please
    since two days i been serching but i didn't get any thing
    Thank's
    Edited by: Lavanya on 24-Sep-2012 00:51

    Lavanya wrote:
    Hi Jeneesh,
    Thank you for your prompt replay
    I didn't try to load this control file
    And i need one more question
    I have Text file in my Machine which Contains very huge data so i was wrote one control file for that, and i got FTP connection also as well as.
    My question is firstly I need to PUT the Text file Into Unix Server isn't?
    so when i trying to put the text file into unix it's giving an error
    ftp>put c:/abc.txt
    Not connectedYou haven't succesfully made your FTP connection to the server.
    e.g.
    c:\>ftp
    ftp> o testserver
    Connected to testserver.mycompany.com.
    220 testserver FTP server ready.
    User (testserver.mycompany.com:(none)): myuser
    331 Password required for myuser.
    Password:
    230 User myuser logged in.
    ftp>then you can use FTP to put your data to the server. Remember, if you are transferring a text file from a windows based operating system to a unix server you need to put it in ASCII mode...
    ftp> ascii
    200 Type set to A.
    ftp>which will automatically convert the windows CR/LF pairs to the single LF character used by unix.

  • So im trying to buy logic pro and just recently put enough money in gift cards on my account but every time i click buy app and go to billing info and then click ok it just shoots me to the first screen and did not charge for app how can i buy it ?

    so im trying to buy logic pro and just recently put enough money in gift cards on my account but every time i click buy app and go to billing info and then click ok it just shoots me to the first screen and did not charge for app how can i buy it ?

    This may sound stupid, but I'm gonna throw it out there anyway. Is it possible, that if I have enough junk on my desktop it might disrupt the signal? It seems odd, but it kind of looks like my signal is strong and relatively steady now that I've cleaned my desktop. I do tend to get very cluttered. I use a lot of reference images and save text clippings to use later... it just piles up very quickly.
    So, I wonder if all that extra effort my system has to do keeping up with the junk might have something to do with the drop outs?

  • Windows migration assistant won't go passed the first screen. Connecting hp files to new Mac mini with Ethernet cable. Also tried USB

    Windows migration assistant won't go passed the first screen. Connecting hp files to new Mac mini with Ethernet cable. Also tried USB

    Are you following these instructions?
    http://support.apple.com/kb/ht4796
    Have yo tired by connecting both to same network vice direct ethernet connection?
    There is no direct USB connection

  • Skipping the selection screen

    Moved to correct forum by moderator.  Please take care to post in the right forum
    Hi  Gurus,
    I have a situation. I have created a zprogram and want to use it in a std txn LI04, and want to run it as individually as well.
    But when it is calling from the std txn it should skip the selection screen and get the values of teh parameters
    as teh same in LI04.
    Please Advice.
    Thanks
    Guarav Kapse.
    Edited by: Matt on Feb 3, 2009 9:54 AM

    Hi,
    Do you have any exit from which u'll call your Z prorgram. If yes, you can use the following statements
    set parameter id ' id '  field <field name>.
    submit <your Z program> and return.
    In your zprogram write:
    get parameter id ' id '  field <field name>.
    It will work.
    cheers
    gaurav

Maybe you are looking for

  • Since I installed Lion, I cannot switch from previous to next page in Chrome nor Firefox with the "swippe" on my mouse.

    Since I installed Lion, I cannot switch from previous to next page in Chrome nor Firefox. Swipping on my mouse, it switches screens instead of the previous behavior.  How do I set it back to the function "previous/next"? Thanks

  • Display menu in Forms10g 10.1.2

    Hi is the popup menu is suported in Forms10g , if it's yes i alwayes got the error FRM-92010 whenever i called the forms taht hold the menu any suggestion's please Thank's alot

  • Group by Address

    Hello All, I have a requirement for a report in XML publisher. We have a report which now has 15 columns and it gives the information of employees. But due to the space restriction on (A4 paper) the business wants the report in a different format. pr

  • Windows XP Home File Protections Prevent Sync

    I have a Palm Vx, and have used it since 1999 with the same PC (!) which was converted many years ago to Windows XP. I just bought a newer computer, also running XP Home. I have had a lot of trouble installing software on it because my ancient comput

  • Reuse FPM configuration in another webdynpro component

    Hello, I would like to define the navigations and buttons in one component configuration . And then use this  in another webdynpro component.  As the buttons/navigation is applicable to multiple requirements. So I would like to reuse it. I tried to d