Usage of reports RDBMIDOC  & BBP_PD_SC_GETLIST?

hi friends
Usage of reports RDBMIDOC  & BBP_PD_SC_GETLIST?
Regards
Vinny

This is a functionality in the system using which data can be distributed to other system when they are changed. The below SAP Help will provide detailed information.
http://help.sap.com/saphelp_erp2005vp/helpdata/en/12/83e03c19758e71e10000000a114084/frameset.htm
Just out of curiosity:
You are posting queries in a very diversified manner i.e. ABAP, SRM, Program related details. I just wonder what you are up to. Quite a lot of them are very basic ones. Are you learning ABAP or SRM ?. What ever it may be, just a small suggestion, SDN has a huge store of information. You can get all you need here. You just need to do a search in the forums/articles/wiki first, before posting a thread; because most of them could have been asked by some one earlier, many fellow members would provided very good suggestions. This will save a lot of your time. This is just a friendly suggestion, nothing meant to hurt you.
Regards
Kathirvel

Similar Messages

  • Sales usage outlier report .

    Hi ,
    I would like to create a report which is based on sales data . Here is the requirement ..
    Sales Usage Outlier Report - Unusual high or low sales for stock materials in a plant (BI) <br> The report should allow the user to select criteria such as: -ABC code -Standard deviation from forecast -Material.
    This report will be used to adjust historical usage for sales outliers that occur during the normal business process. These outliers can cause larger than normal swings in inventory purchases, if not captured during the forecasting process.
    Could you please let me know , do we have any std functionality to show outlier in BW ?
    Regards

    Hi,
    For the following requirment, here is the option,
    Sales Usage Outlier Report - Unusual high or low sales for stock materials in a plant (BI)
    - USE EXCEPTIONS TO HIGHLIGHT THE CHANGES THROUGH COLOR HUES.
    The report should allow the user to select criteria such as: -ABC code -Standard deviation from forecast -Material.
    - CREATE A USERENTRY VARIABLE ON THE "ABC CODE" FIELD AND ATTACH IN THE QUERY DEFINITION
    This report will be used to adjust historical usage for sales outliers that occur during the normal business process. These outliers can cause larger than normal swings in inventory purchases, if not captured during the forecasting process.
    THE REQUIREMENT IS NOT CLEAR.  BUT YOU MUST BE ABLE ANALYSE THE DATA AND CHECK THE USAGE OF SALES OUTLIERS AND DECIDE ON THE FORECAST VALUES.  YOU CAN CREATE CALCULATED KFs to analyse the historical data.
    Thanks.

  • What is "Default" in Usage Statistics report detail?

    I am running RoboHelp Server 8 and am outputing the "Usage Statistics" report which has an option to report on Browsers and Operating Systems. In the results for both is a category called "Default" (see images below). Does anyone know what this means? If you can answer that, maybe you can also tell me what the "Unknown" operating system is? I suspect this maybe an Apple Mac user as I know one of our users has tried accessing the help through the application installed on a Mac.
    Read the RoboColum(n) for a tips, tricks and musings on the Technical Communication Suite products.
    Follow the RoboColum(n) on Twitter

    Further to my previous post, I can confirm that the "Unknown" operating system is definitely NOT an Apple Macintosh user. Having run the report on another area, a seperate "Macintosh" category is displayed thus leaving me in the dark again. If anyone can shed some light on this and the "Default" category I'd be very grateful.
    Read the RoboColum(n) for a tips, tricks and musings on the Technical Communication Suite products.
    Follow the RoboColum(n) on Twitter

  • Failed to update usage tracking reports

    Hi
    I tried to add Usage Tracking reports to OBIEE 11.1.1.6.0 (why it is not installed by default like other BI solutions). It cannot be updated
    Any idea which step wrong?
    Thanks.
    The following objects failed to be updated to the current version of Presentation Services:
    /shared/Usage Tracking/Usage Monitoring Reports/Avg Statistics by Day
    /shared/Usage Tracking/Usage Monitoring Reports/Avg Statistics by Subject Area
    /shared/Usage Tracking/Usage Monitoring Reports/Avg Statistics by User
    /shared/Usage Tracking/Usage Monitoring Reports/Long-Running Queries
    /shared/Usage Tracking/Usage Monitoring Reports/Longest Running Queries by User
    /shared/Usage Tracking/Usage Monitoring Reports/Max Statistics by Day
    /shared/Usage Tracking/Usage Monitoring Reports/Max Statistics by Subject Area
    /shared/Usage Tracking/Usage Monitoring Reports/Max Statistics by User
    /shared/Usage Tracking/Usage Monitoring Reports/Performance by User
    /shared/Usage Tracking/Usage Monitoring Reports/Queries by Hour
    /shared/Usage Tracking/Usage Monitoring Reports/Query Count by Day of Week
    /shared/Usage Tracking/Usage Monitoring Reports/Query Count by Group Name
    /shared/Usage Tracking/Usage Monitoring Reports/Query Count by Subject Area
    /shared/Usage Tracking/Usage Monitoring Reports/Query Count by User
    /shared/Usage Tracking/Usage Monitoring Reports/Query Details by User
    /shared/Usage Tracking/Usage Monitoring Reports/Top 10 Queries

    Not sure how u have implented and also just by seeing that error it is very difficult to tell :(
    Check the below url which has step by step and let us know the updates :)
    http://paulcannon-bi.blogspot.com/2012/11/how-to-install-usage-tracking-in-obiee.html
    http://www.oracle.com/webfolder/technetwork/tutorials/obe/fmw/bi/bi1116/ut/ut.html
    Marks as correct if it is helpful.
    Thanks.

  • Need Usage Pattern Report in OBIEE 11g

    Hi All,
    I have a requirement, where I need to know who logged in, to OBI Application in the last 3 months and who has not. How do I get that? Basing on START_DT in S_NQ_QCCT, I can put a filter with Start Date using BETWEEN RANGE, but since OBIEE logs in only those users who logs in, am not sure how to capture the records for non-logged in users during the same period. I have to report output in a pie chart with the percentages.
    Any help would be highly appreciated, since its an urgent need. Thanks in advance.
    Regards,
    Vinag

    You need to have all users in some custom table and customize the usage tracking BMM model by using outer joins so that you can see user who are not logged in.
    If helps pls mark

  • QM - Usage decision report

    Hello QM masters,
    Is there a standard report to search the history of all usage decisions that have been taken on certain material or batch?
    Best regards,
    Tiago Magalhães

    Hi Tiago, 
    In addition to The above ..
    1. You can select the each inspection lot for the material and click on Extras --> UD Information... for Initial and final UD Details
    2. Click on Extras --> Change History... to get complete details of all changes  for that perticular Inspection Lot.
    Thanks

  • Standard Report Headings,  JAVA script usage,and  Report field fixed width

    My company has purchased Crystal Reports 2008 and I'm in the process of determining if the product will do everything we need and not become a maintenance nitemare. 
    We would like to setup some standard report headings to be used in all reports.  I've setup on already as a SUBREPORT and it works fine. We pass optional parameters that may be blank.
    We have several questions:
    1) Subreport...Once a SUBREPORT is setup as a standard heading and included in multiple reports, we are concerned about what is required if the standard heading subreport changes.  Will each report that uses this need to be opened or handled in any way to pickup the subreport changes?  Any suggestions how to handle this?
    2) Subreport....In order to get the "PAGE N of M" to work in the subreport we've setup the subreport to accept parameters that are passed from the main report and this works fine.  But this requires every report using the standard heading to setup the parameters in order to work.  Is there any other way that would minimize the setup needed for a standard heading?
    3) JAVA...  Can we call a Javascript function? If so, any hints/tips on how/where to do this?
    4) Standard Report... Creating the report is difficult with guessing the width to define to the field.  Is there a way that the report can know and display the exact size of the field being used?  A fixed field defininiton of some sort would make it MUCH easier in the layout of the report.
    5) Standard Report...We are currently testing with a stored procedure for the SQL query result data but because of the application we will need to build the query dynamically for every report.  Is there a way to bind the data and specify the field lengths? 
    6) Standard Report...When using a defined file structure I needed to add another field.  At the time it seemed like I had to start from scratch as the fields that were on the report were now gone.  Is there a update method that can be done import the changes and not loose existing fields on a report? 
    That all for now.  Sorry there are so many questions.  We are trying to clear up as many issues as we can before starting the 100+ reports needed.
    Thanks in advance.

    Hi Vitaly Izmaylov,
    I've taken your advice and split out questions 2-6 into seperate questions.  Anyone else please respond only to question 1 here. 
    I see the Re-Import subreport option....and I guess I can only assume that this means that any change to a report heading file (subreport) must be manually re-imported into every report it is used in.  There are no behind the scenes files or table that maintain a usage of these reports and can automate the population of the changes.
    I was hoping that maybe the subreports would be accessed when called for an pickup any new changes.  So if I create 100 reports with standard heading subreport, I would need to manually open and re-import that file in each report to update a report heading change.
    Does not sound real fun.
    Is all this true?
    Thanks,
    Tim

  • /N/SAPCEM/EINSAT Usage Statement report - ETM Module

    Dear All,
    I have searched for any documentaion or details about this report T-Code /n/SAPCEM/EINSAT but could not find any.
    Could you please check and explain about thisReport.
    How it is calculating percentage? Why it is not coming for all equipments?
    Is it linked with PBE?
    Thank you in advance,
    Regards,
    Mohamed

    Hi,
    The Equipment Usage report will give usage based when the Equipment is in Receipient's Site.
    If it is with Admin, it will consider it as idle & also the Status in the Shipping document is also taken into consideration.
    It will populate only for which Shipping Documents are there & not for all Equipment.
    The report is only ETM relevent. Hope this clarifies your doubts.
    MLN Prasad

  • Query on vCloud Usage Meter Reporting

    Hello ,
    Can vCloud Usage Meter provide report of  vCpu  , vRam  &  Storage Consumption  on monthly basics for each individual  vCloud Workload (Virtual Machine )  ?
    I am looking for   Monthly report of  vCpu/ RAM & Storage  utilization by each  Individual vCloud  Director   Virtual Machine
    Can vCloud usage meter fulfill  this requirement
    Thanks in Advance

    vRealize Operations manager can do this if you want to monitor behaviour/normality, and report based off of this data.  this would connect to vCenter directly to get the data (VMs and templates view in vCenter mimics that of the Organization (vDC) / vApp Structure).
    Chargeback can sample and monitor for the purposes of a creating a bill/invoice for a given VM.  This would connect to both vCloud and vCenter to build the reports.
    vCloud Director which is available to VSPP/vCloud Air Network members has some basic monitoring included in the product, but requires API calls to gather the data and an additional Cassandra/Kairos DB to store the information.

  • SBS 2003 - Usage Server Report

    Hello,
    We use the
    SBS 2003
    server (+Exchange server
    2003). We use Outlook Web Access.
    Unfortunately in the "usage
    report
    server"
    does not show the
    statistics
    about the activity of
    OWA.
    Could you
    advise
    How to
    solve this problem.
    Thank you in advance
    J.Zabransky

    Hi J.Zabransky,
    Just addition. Please re-run the Monitoring Configuration Wizard to enable and configure report preferences
    or other monitoring features again. Then monitor the result.
    Please also refer to following articles and check if can help you.
    Understanding the server usage
    report
    Using the Monitoring Configuration
    Wizard
    If any update, please feel free to let us know.
    Hope this helps.
    Best regards,
    Justin Gu

  • Material Usage Analysis report

    Dear experts,
    We have a standard report. MCRP. In addition to the standard output ,some output has to be included from our development end.
    How to proceed ,i looked at the coding of the transaction but could not follow the exact structure where final data lies.
    I thought making it directly convert to excel and then use OLE library to do changes on cells.
    Any help on any aspect of this issue ?You are welcome.
    Points will be awarded for sure.

    Hi,
    Try Thi - might work.:
    1) Before running the tcode MCRO - (i.e type MCRO in the commond prompt and then do the next steps)
    2) Menu- Got to- User settings
    3) Default your user name will be there.
    4) Now start selecting key figures and charecteristics.
    Save and try to execute.

  • ALV function module usages in report

    Hi All,
    I am writing an ALV report and would like to know whether the following function modules can add some value for my report. The report displays in Grid format using ALV_GRID_DISPLAY.
    REUSE_ALV_EVENTS_GET
    REUSE_ALV_COMMENTARY_WRITE
    REUSE_ALV_VARIANT_F4
    REUSE_ALV_VARIANT_EXISTENCE
    REUSE_ALV_VARIANT_DEFAULT_GET
    I got some example programs for this from the forum but did not quite understand the need of this. So please explain in a simple way how to use this in reports.
    Thanks
    Ricky

    Hi,
    SAP provides a set of ALV (ABAP LIST VIEWER) function modules which can be put into use to beautify the output of a report. This set of ALV functions is used to enhance the readability and functionality of any report output. Cases arise in SAP when the output of a report contains columns extending more than 255 characters in length.  In such cases, this set of ALV functions can help choose selected columns and arrange the different columns from a report output and also save different variants for report display. This is a very efficient tool for dynamically sorting and arranging the columns from a report output. The report output can contain upto 90 columns in the display with the wide array of display options.
    The commonly used ALV functions used for this purpose are;
    1.     REUSE_ALV_VARIANT_DEFAULT_GET
    2.     REUSE_ALV_VARIANT_F4
    3.     REUSE_ALV_VARIANT_EXISTENCE
    4.     REUSE_ALV_EVENTS_GET
    5.     REUSE_ALV_COMMENTARY_WRITE
    6.   REUSE_ALV_FIELDCATALOG_MERGE
    7.   REUSE_ALV_LIST_DISPLAY
    8.     REUSE_ALV_GRID_DISPLAY
    9.     REUSE_ALV_POPUP_TO_SELECT
    The different steps used for getting the above function modules into use are :
    Step 1
    DATA DECLARATION
    Sap standard type pools: SLIS, KKBLO.
    Sap standard tables types taken from the type pools are:  SLIS_LAYOUT_ALV,
                                             SLIS_T_FIELDCAT_ALV,
    SLIS_T_LISTHEADER,
    SLIS_T_EVENT,
    SLIS_SELFIELD.
    Internal tables to used in the program declared based on the above table types
    DATA:  I_LAYOUT TYPE SLIS_LAYOUT_ALV,
                I_FIELDTAB TYPE SLIS_T_FIELDCAT_ALV,
               I_HEADING TYPE SLIS_T_LISTHEADER,
    I_EVENTS TYPE SLIS_T_EVENT.
    TYPES:  KKBLO_SELFIELD TYPE SLIS_SELFIELD.
    Step 2 (Optional)
    SELECTING THE VARIANTS FOR INITIAL LIST DISPLAY (DEFAULT VARIANT)
    The variants in the list display can be both user-specific and general. The user can programmatically set the initial (default) variant for list display.
    The default variant can be found using the function module 'REUSE_ALV_VARIANT_DEFAULT_GET'.
    Sample code:
    CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
           EXPORTING
                i_save     = variant save condition ( A=all, U = user-specific )
           CHANGING
                cs_variant = internal table containing the program name (and the default variant---optional )
           EXCEPTIONS
                not_found  = 2.
    The user can also choose from the list of existing variants using the function module ‘REUSE_ALV_VARIANT_F4’.
    Step 3
    DEFININING OUTPUT CHARACTERISTICS: PREPARING DISPLAY FIELDS CATALOG
    A field catalog is prepared using the internal table (I_FIELDCAT) of type SLIS_T_FIELDCAT_ALV. Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields).
    A field catalog is required for every ALV list output to add desired functionality (i.e. Key, Hotspot, Specific headings, Justify, Col. position etc) to certain fields of the output. If not mentioned specifically, then the defaults are taken. The possible values and defaults are listed below.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module.
    The minimal field catalog is documented below. This can be done in a routine using a local variable. The user can use the other optional parameters to assign output attributes to different fields in the output, which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    1.     The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE. In this case the attributes of the different fields is taken directly from the table and the attributes (key fields, length, texts etc) need to state explicitly.
    2.     all fields in this structure are to be output
    3.     The structure name is passed to ALV in the parameter I_STRUCTURE_NAME of the function module REUSE_ALV_LIST_DISPLAY.
    All the values entered in the catalog are specific to the particular field whose name is entered in the fieldname FIELDNAME of the fieldcat structure. The name of the table is also entered in the corr. Fieldname TABNAME of the structure.
    The different possible attributes are:
    •     Row_pos (row position): Only relevant if the list output is to be multi-line (two or three lines) by default. So, this attribute can be used maintain certain level of alignment in the output.
                         Value set: 0, 1 – 3
    •     Col_pos (column position): This parameter is relevant when the fields in the output are to be different from the sequence of the fields in the internal table used for display.       The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the internal table field sequence.
    Value set: 0, 1 – 60
    •     Fieldname (field name): This is the name of the internal table field for which the parameters are passed in the catalog.
    Value set: internal output table field name (required parameter)
    •     Tabname (internal output table): Name of the internal output table that contains the field FIELDCAT-FIELDNAME above.
                         Value set: SPACE, internal output table name.
    •     Ref_fieldname (reference field name): Name of the Data Dictionary field referred to. This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the        Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
        Value set: SPACE, Data Dictionary field name.
    •     Ref_tabname (reference table/structure field name): Structure or table name of the referred Data Dictionary field.        This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Value set: SPACE, name of a Data Dictionary structure or table
    Link to currency unit
    •     Cfieldname (currency unit field name): This is used for currency fields that have a reference to any unit field. This is only relevant for amount columns with associated unit. This parameter contains the Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name
    •     Ctabname (internal currency unit field output table): Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Value set: SPACE, output table field name.
            Link to measurement unit
    •     Qfieldname (measurement unit field name): Only relevant for quantity columns with unit link. Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME. The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name.
    •     Qtabname (internal measurement unit field output table): Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Value set: SPACE, output table field name.
    •     Outputlen (column width): This parameter is used if the desired output length for a field is desired to be different from the internal output table field. For fields with a Data Dictionary link this parameter can be left initial. For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    Initial = column width is the output length of the referred Data Dictionary field (domain).
    N = column width is n characters.
          Value set: 0 (initial), n.
    •     Key (key column): By default, the system makes some fields in the output as key fields, provided the fields are key fields in their referencing table. Using this parameter, fields other than key fields of the referencing table can be made key field. This parameter is most important if the output needs to contain some field which are not scrollable or cannot be hidden.
    If the internal output table contains fields that are key fields from different tables, then all those fields in the report output becomes unscrollable and cannot be hidden. So, the fields in the output internal table should not be referenced from tables in which they are key fields. Instead, they should be referenced to the tables in which they are not key fields, incase they are not desired as key field in the output.
    'X' = key field (key field output in color) and Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
          Value set: SPACE, 'X'.
    •     Key_sel (hideable key column): This parameter is only relevant for the fields which are made key fields using FIELDCAT-KEY = 'X'. Using this parameter the Key field can be hidden interactively.
    The key column sequence cannot be changed interactively by the user. The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    Value set: SPACE, 'X'.
    •     No_out (field in field list): This parameter is used to remove certain fields from the output during initial display.  The user can however interactively choose the field for output from the field list in the display variant.
                'X' = field is not displayed in the current list.
            Value set: SPACE, 'X'.
    •     Tech (technical field): This parameter is used to make certain field display only in the field catalog. The fields with this parameter set cannot be output in the list nor can they be displayed interactively from the catalog.
                        'X' = technical field.
           Value set: SPACE, 'X'.
    •     Emphasize (highlight columns in color): As name suggests, this field parameter is used to highlight certain field with chosen colors.
    Value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off ,'1'=on).
    'X' = column is colored with the default column highlight color.
                        'Cxyz' = column is colored with a coded color:
                      -  C: Color (coding must begin with C)
                     -  X: color number
                      -  Y: bold
                       -  Z: inverse
    •     Hotspot (column as hotspot): This parameter is used to make certain field appear as hotspot i.e. a hand is displayed if the cursor is positioned on the field value. Single click on such fields cause the PICK OR F2 events to happen.
             Value set: SPACE, 'X'.
                        'X' = column cells are output as hotspots.
    •     Fix_column (fix column): This parameter is used to fix certain columns in the output. All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively.
                         Value set: SPACE, 'X'.
            'X' = column fixed (does not scroll horizontally).
    •     Do_sum (sum over column): the user can also call this function interactively.
                      Value set: SPACE, 'X'.
    'X' = a sum is calculated over this internal output table field.
    •     No_sum (sums forbidden): No sum can be calculated over this field, although the data type of the field would allow summing.
             Value set: SPACE, 'X'.
    •     Icon: The parameter displays certain column contents as icons. The internal output table column contents must be valid icon strings.
                        Value set: SPACE, 'X'.
                         'X' = column contents to be output as an icon.
    •     Symbol: The internal output table column must be a valid symbol character.
    Value set: SPACE, 'X'
                        'X' = column contents are to be output as a symbol.
    •     Just (justification): This parameter is used for alignment of the contents of the output table. This is only relevant for CHAR or NUMC fields in the output internal table. The justification of the column header always follows the justification of the columns. Independent justification of the column header is not possible.
    Value set: SPACE, 'R', 'L', and ‘C’.
           ' ' = Default justification for this data type
           'R' = right-justified output
           'L' = left-justified output
           'C' = centered output.
    •     Lzero (leading zeros): By default ALV outputs NUMC fields right-justified without leading zeros. Using this parameter only the NUMC fields can be displayed with leading zeroes.
                       Value set: SPACE, 'X'.
                        'X' = output with leading zeros.
    •     No_sign (no +/- sign): This parameter is used to suppress the signs of the output fields. It is only relevant for the value fields.
        Value set: SPACE, 'X'.
               'X' = value output without +/ sign.
    •     No_zero (suppress zeros): Only relevant for value fields.
                 Value set: SPACE, 'X'.
                        'X' = suppress zeros.
    •     Edit_mask (field formatting): To apply the report output formatting options same as in the WRITE statement in report writing.
               Value set: SPACE, template.
    The following parameters are used for customizing the texts in the heading of the output of the columns. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored.
    If the user changes the column width interactively, the column header text with the appropriate length is always used.
    The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
         The 'long field label' is also used in display variant definition,
            Sort, etc.  Popup.
    •     seltext_l (long field label)
    •     seltext_m (medium field label)
    •     seltext_s (short field label)
    •     reptext_ddic(header) Analogous to the Data element main header
    •     Ddictxt (specify text) : You can specify with values 'L', 'M',  and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Value set: SPACE, 'L', 'M', and ‘S’.
    Sample code:
    Suppose I_PO_DETAILS is an internal table containing two fields EBELN (PO number) and EBELP (PO item no).
    DATA: L_FIELDCAT TYPE SLIS_FIELDCAT_ALV.     “Local variable to hold the parameters                                                                               
    for a particular field of the field catalog
      CLEAR L_FIELDCAT.
      L_FIELDCAT-TABNAME   = 'I_PO_DETAILS'.
      L_FIELDCAT-FIELDNAME = 'EBELN'.
      L_FIELDCAT-KEY = 'X'.         “The PO no is made the key field,
                          “Colored and non scrollable
      L_FIELDCAT-HOTSPOT = 'X'.     “The po no becomes a hotspot
      L_FIELDCAT-SELTEXT_S = ‘P.O No’.
      L_FIELDCAT-SELTEXT_M = 'P order No'.
      L_FIELDCAT-SELTEXT_L = 'Purchase order No'.
      APPEND L_FIELDCAT TO I_FIELDTAB.
      CLEAR L_FIELDCAT
      L_FIELDCAT-TABNAME   = 'I_PO_DETAILS'.
      L_FIELDCAT-FIELDNAME = 'EBELN'.
      L_FIELDCAT-KEY = 'X'.         “The po item no is made the key field,
                          “Colored and non scrollable
      L_FIELDCAT-SELTEXT_S = 'Item No'.
      L_FIELDCAT-SELTEXT_M = 'Item No`.
      L_FIELDCAT-SELTEXT_L = 'PO Item No'.
      APPEND L_FIELDCAT TO I_FIELDTAB.
      CLEAR L_FIELDCAT
    Thus the catalog for the report output is prepared.
    Step 4
    The next step is to build an event table, which are used for firing both user commands and the system dependent events i.e. top of page, end of page etc.
    A list of possible events is populated into an event table (I_EVENTS) when this table is passed to the function module REUSE_ALV_EVENT_NAMES_GET. The return table from this function module contains all the possible events.
    The function module contains following import and export parameters.
    IMPORTING PARAMETERS: I_LIST_TYPE
    This parameter has possible values from 0-4.
    The parameter I_LIST_TYPE is of TYPE SLIS_LIST_TYPE and is DEFAULT 0 .
    EXPORTING PARAMETERS:  I_EVENTS table.
    This table is of TYPE SLIS_T_EVENT and returns to the program the name of all the possible events.
    The table structure contains the fields:
         I_EVENTS-NAME: Name of the Callback event.
    I_EVENTS-FORM: Name of the form routine that should be called in the calling program at the event.
    Only events with a form routine name are processed.
    The I_EVENTS table returns with the following possible constants:
    1.     Slis_ev_item_data_expand TYPE slis_formname VALUE 'ITEM_DATA_EXPAND'.     
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT. Exit for passing item entries (ITEM table) for a header record that was expanded interactively by the user.
    2.     Slis_ev_reprep_sel_modify TYPE slis_formname VALUE 'REPREP_SEL_MODIFY'.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to       be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header that is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that    entries are not repeated in the item table.
        RS_SELFIELD is initial in this case.         
    3.     Slis_ev_caller_exit_at_start TYPE slis_formname VALUE 'CALLER_EXIT'.
    Is called at the beginning of the function module to make special settings. It is not usually used.          
    4.     Slis_ev_user_command TYPE slis_formname VALUE 'USER_COMMAND'.
    As this is a frequently-used Callback event, the form routine can also be passed        directly in the interface by passing the user command in the IMPORTING parameter           I_CALLBACK_USER_COMMAND.
    5.     Slis_ev_top_of_page TYPE slis_formname VALUE 'TOP_OF_PAGE'.
       Equivalent to the list processing TOP-OF-PAGE event.           
    6.     Slis_ev_top_of_coverpage TYPE slis_formname VALUE 'TOP_OF_COVERPAGE'.       
    The selection information and list status are output together (if they exist) on a separate page by default
    7.     Slis_ev_end_of_coverpage TYPE slis_formname VALUE 'END_OF_COVERPAGE'.       
    Analogously to TOP_OF_COVERPAGE the user can add other information
    to the information output by ALV (selection information, list status) at this event.
    8.     Slis_ev_foreign_top_of_page TYPE slis_formname VALUE ‘FOREIGN_TOP_OF_PAGE'.
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    9.     Slis_ev_foreign_end_of_page TYPE slis_formname VALUE 'FOREIGN_END_OF_PAGE'.  
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.                             
    10.     Slis_ev_pf_status_set TYPE slis_formname VALUE 'PF_STATUS_SET'.
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a          template for a user-specific status. As this is a frequently used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    11.     Slis_ev_list_modify TYPE slis_formname VALUE 'LIST_MODIFY'.     
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
                                             R_INDEX LIKE SY-TABIX
                                             R_INDEX_ITEM LIKE SY-TABIX
                                             R_INDEX_SUM LIKE SY-TABIX.
    12.     Slis_ev_top_of_list TYPE slis_formname VALUE 'TOP_OF_LIST'.  
    Information output at the start of the list     
    13.     Slis_ev_end_of_page TYPE slis_formname VALUE 'END_OF_PAGE'.
    Information output at the end of a page. This is only called for printing.
    14.     Slis_ev_end_of_list TYPE slis_formname VALUE 'END_OF_LIST'.     
    Information output at the end of the list
    15.     Slis_ev_after_line_output TYPE slis_formname VALUE 'AFTER_LINE_OUTPUT'.
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    16.     Slis_ev_before_line_output TYPE slis_formname VALUE   'BEFORE_LINE_OUTPUT'.       
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.         
    17.     Slis_ev_subtotal_text TYPE slis_formname VALUE  'SUBTOTAL_TEXT'.                        
    This event table (I_EVENTS) is now checked with the desired constants. If the desired constant is found, then the corresponding field for the FORM NAME is populated with the name of the routine containing the corresponding event.
    Sample code :
    FORMNAME_TOP_OF_PAGE TYPE SLIS_FORMNAME VALUE 'TOP_OF_PAGE',
    FORMNAME_END_OF_PAGE TYPE SLIS_FORMNAME VALUE 'END_OF_PAGE', FORMNAME_USER_COMMAND TYPE SLIS_FORMNAME VALUE 'USER_COMMAND'.
    DATA: L_I_EVENT TYPE SLIS_ALV_EVENT.
      CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
           EXPORTING
               I_LIST_TYPE = 0
           IMPORTING
                ET_EVENTS   = I_EVENTS.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_TOP_OF_PAGE
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_TOP_OF_PAGE TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_END_OF_PAGE
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_END_OF_PAGE TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
      CLEAR L_I_EVENT.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_USER_COMMAND
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_USER_COMMAND TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
    This will prepare the events table for the report.
    The report will contain three forms for the above events:
    1.     FORM TOP_OF_PAGE : This form will contain the top of page event for the report i.e header etc
    Using the function module ‘REUSE_ALV_COMMENTARY_WRITE’, the internal table containing the headings for top of page event can be passed to the list output. Also, any logo specific to the report can be passed to the function module.
    2.     FORM END_OF_PAGE : This form will contain the end of page event for the report i.e footer etc
    3.     FORM USER_COMMAND : This form will contain the desired user command i.e pick/line selection
    Step 5
    A layout is build for the report output list description USING the internal table declared above (I_LAYOUT).
    Output list description structure.
         The parameters are described under the following heads:
    •     Display options
    •     Exceptions
    •     Totals
    •     Interaction
    •     Detail screen
    •     Display variants (only for hierarchical-sequential lists)
    •     Color
    •     Other
    The layout table is of type slis_layout_alv_spec and has the following fields:
    Display options                                                
    1. Colwidth_optimize (1) TYPE c: This parameter optimizes the length of the different columns in the output. The width of the different col. now depends on the max. Length of the data in the column.
    Value set: SPACE, 'X'
    'X' = optimizes the column width so that all contents are displayed completely.                   
    2. No_colhead(1) TYPE c : This parameter suppresses the column headings                    
    Value set: SPACE, 'X'.
    'X' = column headers are not output
    3. No_hotspot(1) TYPE c :  The heading of the report output are not output as hotspot.       
    Value set: SPACE, 'X'.
    'X' = column headers are not output as hotspot
    4. Zebra(1) TYPE c : The report is output in the striped pattern.             
    Value set: SPACE, 'X'.
    'X' = striped pattern (e.g. for wide lists)
    5. No_vline(1) TYPE c : The report output contains columns only separated by space and no lines.  It is not relevant for: hierarchical-sequential lists and multiple-line lists.
    Value set: SPACE, 'X'.
    'X' = columns separated by SPACE
    6. No_min_linesize(1) TYPE c : The report  line size is equal to the width of the list. It is not relevant for block lists.
    Value set: SPACE, 'X’.
    'X' = line size depends on list width
    '  ' = Line size is set to 80 or MIN_LINESIZE (if > 0) .
    7. Min_linesize LIKE sy-linsz: The report output contains a minimum possible length of line. If initial min_linesize is set to 80 by default, then this parameter is used to customize it. The prerequisite for this is that the parameter no_min_linesize should be ' '.
    Value set: 0, 10 - 250
    If the list is wider, the format uses the list width (maximum 250 or MAX_LINESIZE (if > 0)).
    8. Max_linesize LIKE sy-linsz: The default max. Linesize is 250. To change this default value, this parameter can interactively-define the maximum list width setting.
    Value set: 0, 80 - 1020
    9. Window_titlebar LIKE rsmpe-tittext: To set the titlebar on the report output.                            
               10. No_uline_hs(1) TYPE c.
    Exceptions                                                 
    11. Lights_fieldname TYPE slis_fieldname: Internal output table field containing the codes of exceptions to be output.
                      Output table field code:  '1' = red traffic light
                                    '2' = yellow traffic light
                                         '3' = green traffic light Fieldname for exception 
         Value set: SPACE, internal output table field name.
    12. Lights_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter LIGHTS_FIELDNAME. If LIGHTS_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists. Only relevant for hierarchical-sequential lists.
    .     Value set: SPACE, internal output table name.
    13. Lights_rollname LIKE dfies-rollname: The documentation of this data element is displayed when you call F1 help for an exception column.
    Value set: SPACE, data element name.
               14. Lights_condense(1) TYPE c : If a list record is output with 'red traffic light', each
               Subtotal that includes this record is also output with 'red traffic light'.
               Value set: SPACE, 'X'
               'X' = the 'maximum' exception of the items in the subtotal is output at subtotal level.
    Sums                                                       
    15. No_sumchoice(1) TYPE c : This parameter allows the choice for summing up
    Only by fieldcatalog.
    Value set: SPACE, 'X'
    'X' = fields which are to be summed, passed by the calling program (FIELDCAT-DO_SUM = 'X'). The user should not be able to change this value interactively.
    16. No_totalline(1) TYPE c : Removes the option of having totals after sub-totals.
    Value set: SPACE, 'X'
    'X' = no total record is to be output. Subtotals can still be calculated and output. The fields in the subtotals are flagged DO_SUM = 'X' in the field list.
    17. No_subchoice(1) TYPE c : Does not allow the user to interactively change the field chosen for subtotals.
    Value set: SPACE, 'X'
    'X' = value whose change triggers subtotals, provided by the calling program. The user should not be able to change this value interactively.
    18. No_subtotals(1) TYPE c : No subtotals possible          
    Value set: SPACE, 'X'
    'X' = no subtotals.
    19. Numc_sum(1)  TYPE c : Totals only possible for NUMC-Fields.
    20. No_unit_splitting TYPE c: No separate total lines by inh.units   
    21.totals_before_items TYPE c: Display totals before the items   
    22. Totals_only(1) TYPE c :  Show only totals      
    Value set: SPACE, 'X'
    'X' = only total records are output.
    23. Totals_text(60) TYPE c : Text for 1st col. in totals   
    Value set: SPACE, string (max.60)
    ' ' = The first column in the total record contains an appropriate number of '*'s to indicate the total by default. If the first column is wide enough, the string 'Total' is output after the asterisks.
    'String’ = The string passed is output after the total indicated by '*', if the column is wide enough.
    24. Subtotals_text(60) TYPE c : Texts for subtotals
    Value set: SPACE, string (max.60)
    ' ' = In the first column of subtotal records, the subtotal is indicated by an appropriate number of '*' by default. If the first column is not a subtotal criterion, the string 'Total' is output after the asterisks, if the column is wide enough.
    'String’ = the string passed is output after the subtotal indicated by '*', if the column is wide enough and the first column is not a subtotal criterion. If it is a subtotal criterion, its value is repeated after the total, if the column is wide enough.
    Interaction                                                      
    25. Box_fieldname TYPE slis_fieldname: Fieldname for checkbox in the report output. If the list has checkboxes at the start of records (for selecting several records), this parameter contains the internal output table field name indicated by the checkbox selection column. The field is a checkbox at the start of list records without a list header.
    Value set: SPACE, internal output table field name
    26. Box_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter BOX_FIELDNAME. If BOX_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists.
    Value set: SPACE, internal output table name.
    27. Box_rollname LIKE dd03p-rollname: rollname for checkbox          
    28. Expand_fieldname TYPE slis_fieldname: fieldname flag ‘expand’. The user can show or hide the items by clicking on the folder symbol (hotspot). If the items for a header entry are only to be read by the calling program and passed to ALV when a header has been expanded interactively, this can be controlled via the CALLBACK event        'ITEM_DATA_EXPAND'.
    29. Hotspot_fieldname TYPE slis_fieldname: Used to make the fieldname flag hotspot.
    30. No_input(1) TYPE c : The fields are only display fields.
            Value set: SPACE, 'X'
    'X' = all ready-for-input fields in a list are displayed as not ready-for-input. (Record selection checkboxes and fields which can be made ready-for-input via the field list parameter FIELDCAT-INPUT = 'X')
    31. F2code LIKE sy-ucomm: To assign an ALV standard function code to double-click (F2), assign the function code to this parameter. Ex.: to assign the ALV standard function 'Detail' ('&ETA') to F2.
                      => LAYOUT-F2CODE = '&ETA'.
    Value set: SPACE, function code
    32. Confirmation_prompt: confirm. Prompt when leaving       
    Value set: SPACE, 'X'
    'X' = if one of the functions ‘Back (F03)', ‘Exit (F15)' or ‘Cancel (F12)' occurs, a confirmation prompt appears.
    33. Key_hotspot(1) TYPE c : The key fields are displayed as hotspot. The columns defined in the field catalog as key fields (FIELDCAT-KEY = 'X') are output as hotspots, i.e. clicking on a key column (highlighted in color in the list) calls the function under F2.
    Value set: SPACE, 'X'.
    34. Reprep(1) TYPE c :  report report interface active.     
    35. Group_buttons(1) TYPE c :  group-buttons for COL1 - COL5 . Group output fields via FIELDCAT-SP_GROUP in the field list, and pass the group name to the list module in the interface parameter IT_SPECIAL_GROUPS.           
    Value set: SPACE, 'X'.
    36. No_keyfix(1) TYPE c : Used to make the key fields scrollable.
    Value set: SPACE, 'X'.
    ' ' = The key columns defined in the field catalog by FIELDCAT-KEY = 'X' are fixed in the list output. These columns do not scroll horizontally. The item table key columns are fixed in hierarchical-sequential lists. The header table key fields are not considered here.
    'X' = key columns not fixed
    37. Get_selinfos(1) TYPE c : To read selection screen.
    Value set: SPACE, 'X'.
    If the calling program is a report with an ABAP/4 selection screen, setting this parameter makes ALV read the selection screen again. If the selections are read successfully, a pushbutton, via which the user can call a popup which lists the report selections in a simple form, becomes active on the results list output by ALV.
    38.     group_change_edit(1) TYPE c :  Settings by user for new group     
    Value set: SPACE, 'X'
    'X' = the user can enter a format option for each sort criterion in the sort/subtotal popup, for the list format when this value changes (e.g. new page or underline).
    39.     No_scrolling(1) TYPE c : Does not allow scrolling of the list to the right.
    Value set: SPACE, 'X'.
    40. Expand_all(1) TYPE c : Expand all positions                   
    Detailed screen                                                    
    40.     Detail_popup(1) TYPE c : show detail in popup.
    Value set: SPACE, 'X'
    '  '  = List record detail display in full-screen mode, with top-of-page.
    'X'  = list record detail display in popup (without top-of-page).
    41. Detail_initial_lines(1) TYPE c : show also initial lines   
    Value set: SPACE, 'X'
    '  ' = Only fields whose contents are not initial are output in the detail view.
    'X' = initial field contents are also output in detail.
    41.     detail_titlebar(30) type c : Titlebar for detail screen
    Value set: SPACE, string (max.30)
    ` ' = ' Detail: Display' is output as the title of the detail window.
                  'String’ = the string passed is output as the title of the detail window. 
    Display variants                                                   
    42. Header_text (20) TYPE c: Text for header button. Only relevant for hierarchical-sequential lists. You can toggle between display field and field list views via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.   
    Value set: SPACE, CHAR (20)
    ' ' = The header table field pushbutton text is 'Header' by default.
    CHAR (20) = header table field pushbutton text.
    43.item_text(20) TYPE c : Text for item button. Only relevant for hierarchical-sequential lists. You can toggle the view between the display fields and the field list via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.        
    Value set: SPACE, CHAR (20)
    ' ' = The pushbutton text for the item table fields is 'Item' by default.
    CHAR (20) = item table field pushbutton text.
    44.default_ item(1) TYPE c : Items as default. Only relevant for hierarchical-sequential lists.
         Value set: SPACE, 'X'
    ' ' = The header table fields are displayed by default in the display variant definition popup. The user can switch to the item table fields interactively.
    'X' = the item table fields are displayed by default in the display variant Definition Popup.    The user can switch to the header table fields interactively.
    Colour                                                       
    45. Info_fieldname TYPE slis_fieldname: infofield for listoutput. A whole list record can be colored individually using a color code in a column of the internal output table for the record. Assign the name of the field containing the color code to this parameter.
    Value set: SPACE, internal output table field name
    The internal output table field must be of type CHAR(3).
    The code must have the following syntax:  'Cxy':
            C = color (all codes must start with 'C')
            X = color number ('1'-'9')
            Y = bold ('0' = off, '1' = on)
    46. Coltab_fieldname TYPE slis_fieldname: Cells can be colored individually using a color code which is contained in a column of the internal output table for the record containing the cell. Assign the name of the field to this parameter.       
    Others                                                
    47. List_append(1) TYPE c :  no call screen. It is only useful to output block-lists without specifying the above modules if the number of list blocks exceeds, or may exceed, the maximum number specified in the block module documentation. These operations are not possible for user-defined block lists.
    Example code :
           I_LAYOUT-f2code       = ws_fcode.
           I_LAYOUT-zebra        = 'X'.
    I_LAYOUT-colwidth_optimize = 'X'.
    I_LAYOUT-no_keyfix = 'X'.
    I_LAYOUT-get_selinfos = 'X'.
    I_LAYOUT-no_hotspot = 'X'.
           I_LAYOUT-no_input = 'X'.
    I_LAYOUT-hotspot_fieldname = FIELDNAME.
    I_LAYOUT-no_input          = ‘X’.
    I_LAYOUT-no_vline          = `X’.
    I_LAYOUT-no_colhead        = ‘ ‘.
    I_LAYOUT-lights_condense   = ` `.
    I_LAYOUT-totals_text       = ` `.
    I_LAYOUT-subtotals_text    = ` `.
    I_LAYOUT-totals_only       = ` `.
    I_LAYOUT-key_hotspot       = ‘X’.
    I_LAYOUT-detail_popup      = ‘X’.
    I_LAYOUT-group_change_edit = ‘X’.
    I_LAYOUT-GROUP_BUTTONS     = ‘X’.
    Step 6
    This step is required to get the selection screen information in the report output.
    The prerequisite for this is to set the parameter LAYOUT-GET_SELINFOS of the IMPORTING structure.
    The parameters to be passed in the IS_SEL_HIDE table are:
    o mode:              'R' = only the entries passed in the internal table IS_SEL_HIDE-T_ENTRIES       
    Are output in the pop up. Selection info, which the list tool read in the selection screen (when called by a report with a selection screen), is replaced by the values passed.
    'S' = the selection info which the list tool read in the selection screen of the calling report are modified by the entries in the table IS_SEL_HIDE-T_ENTRIES.
    o t_entries:         Selection info table
    o t_entries-mode:   'A' = output the selection info for the current table record in the info popup.
    'D' = do not output select option or SELNAME parameter selection info in   the popup.
    o t_entries-selname: (only used in t_entries-mode = 'D') : Name of the select option or parameter.
    The following table fields are only used in t_entries-mode = 'A'. They contain the selection information to be added.
    •     t_entries-field:  DDIC field name of the field for which selection information is to be output.
    •     t_entries-table:  DDIC table names of t_entries-field.
    •     t_entries-stext:  Field name in info popup.
    •     If t_entries-field and t_entries-table have been entered, this text is taken from DDIC.
    •     t_entries-valuf:  Selection condition 'from' value (external format)
    •     t_entries-valut:  Selection condition 'to' value (external format)
    •     t_entries-sign0:  (I)nclusive (E)xclusive
    •     t_entries-option:  All values of the select options Option field allowed.
    Step 6
    The Table IT_SORT is populated with the sort criteria for the different fields.
    The caller specifies the sorting and/or subtotaling of the basic list in the internal table IT_SORT.
    This internal table has the following fields:
         o spos :  Sort sequence
         o fieldname :  Internal output table field name
         o tabname : Only relevant for hierarchical-sequential lists. Name of the internal output table.
         o up : 'X' = sort in ascending order
         o down : 'X' = sort in descending order
         o subtot : 'X' = subtotal at group value change
         o group : '* ' = new page at group value change ,'UL' = underline at group value change
                             Step 7
    The final step in the output of the report is the use of two ALV functions modules.
    1.     REUSE_ALV_FIELDCATALOG_MERGE
    2.     REUSE_ALV_LIST_DISPLAY
    The first function module is used to pass the field catalog to the report output and merge it with the internal output table.
    FUNCTION reuse_alv_fieldcatalog_merge.                                
    ""Lokale Schnittstelle:                                             
    *” IMPORTING                                                    
    *"             VALUE(I_PROGRAM_NAME) LIKE  SY-REPID OPTIONAL          
    *"             VALUE(I_INTERNAL_TABNAME) TYPE  SLIS_TABNAME OPTIONAL  
    *"             VALUE(I_STRUCTURE_NAME) LIKE  DD02L-TABNAME OPTIONAL   
    *"             VALUE(I_CLIENT_NEVER_DISPLAY) TYPE  SLIS_CHAR_1        
    *"                             DEFAULT 'X'                            
    *"             VALUE(I_INCLNAME) LIKE  TRDIR-NAME OPTIONAL            
    *"       CHANGING                                                     
    *"             VALUE(CT_FIELDCAT) TYPE  SLIS_T_FIELDCAT_ALV           
    *"       EXCEPTIONS                                                   
    *"              INCONSISTENT_INTERFACE                                
    *"              PROGRAM_ERROR                                         
    Import parameters 
    I_PROGRAM_NAME: Program in which the internal output table is declared and populated   
    I_INTERNAL_TABNAME: Internal output table name
    I_STRUCTURE_NAME: Structure name (structure, table, and view)
    I_CLIENT_NEVER_DISPL: Hide client fields default ‘X’
    I_INCLNAME: Data declarations include name
    CHANGING parameter
    CT_FIELDCAT: Field catalog with field descriptions
    The variant based on a program-internal table should only be used for rapid prototyping since the following restrictions apply:                                                                               
    1.   Performance is affected since the code of the table definition must always be read and interpreted at runtime.                                                                               
    2.   Dictionary reference are only considered if the keywords LIKE or  INCLUDE STRUCTURE (not TYPE) are used.
    Step 8
    The other function module is used to display the internal output table with the contents
    FUNCTION reuse_alv_list_display.                                          
    ""Lokale Schnittstelle:                                                 
    *” IMPORTING                                                        
    *"             VALUE(I_INTERFACE_CHECK) DEFAULT SPACE                     
    *"             VALUE(I_CALLBACK_PROGRAM) LIKE  SY-REPID DEFAULT SPACE     
    *"             VALUE(I_CALLBACK_PF_STATUS_SET) TYPE  SLIS_FORMNAME        
    *"                             DEFAULT SPACE                              
    *"             VALUE(I_CALLBACK_USER_COMMAND) TYPE  SLIS_FORMNAME         
    *"                             DEFAULT SPACE                              
    *"             VALUE(I_STRUCTURE_NAME) LIKE  DD02L-TABNAME OPTIONAL       
    *"             VALUE(IS_LAYOUT) TYPE  SLIS_LAYOUT_ALV OPTIONAL            
    *"             VALUE(IT_FIELDCAT) TYPE  SLIS_T_FIELDCAT_ALV OPTIONAL      
    *"             VALUE(IT_EXCLUDING) TYPE  SLIS_T_EXTAB OPTIONAL            
    *"             VALUE(IT_SPECIAL_GROUPS) TYPE  SLIS_T_SP_GROUP_ALV         
    *"                             OPTIONAL                                   
    *"             VALUE(IT_SORT) TYPE  SLIS_T_SORTINFO_ALV OPTIONAL          
    *"             VALUE(IT_FILTER) TYPE  SLIS_T_FILTER_ALV OPTIONAL          
    *"             VALUE(IS_SEL_HIDE) TYPE  SLIS_SEL_HIDE_ALV OPTIONAL        
    *"           VALUE(I_DEFAULT) DEFAULT 'X'
    "             VALUE(I_SAVE) DEFAULT SPACE                             
    "             VALUE(IS_VARIANT) LIKE  DISVARIANT                      
    "                             STRUCTURE  DISVARIANT DEFAULT SPACE     
    "             VALUE(IT_EVENTS) TYPE  SLIS_T_EVENT OPTIONAL            
    "             VALUE(IT_EVENT_EXIT) TYPE  SLIS_T_EVENT_EXIT OPTIONAL   
    "             VALUE(IS_PRINT) TYPE  SLIS_PRINT_ALV OPTIONAL           
    "             VALUE(IS_REPREP_ID) TYPE  SLIS_REPREP_ID OPTIONAL       
    "             VALUE(I_SCREEN_START_COLUMN) DEFAULT 0                  
    "             VALUE(I_SCREEN_START_LINE) DEFAULT 0                    
    "             VALUE(I_SCREEN_END_COLUMN) DEFAULT 0                    
    "             VALUE(I_SCREEN_END_LINE) DEFAULT 0                      
    "       EXPORTING                                                     
    "             VALUE(E_EXIT_CAUSED_BY_CALLER)                          
    "             VALUE(ES_EXIT_CAUSED_BY_USER) TYPE  SLIS_EXIT_BY_USER   
    "       TABLES                                                        
    "              T_OUTTAB                                               
    "       EXCEPTIONS                                                    
    "              PROGRAM_ERROR
    Import parameters
    I_INTERFACE_CHECK: Interface consistency check log output.
    I_CALLBACK_PROGRAM: Name of the calling program
    I_CALLBACK_PF_STATUS_SET: Set EXIT routine to status.   
    I_CALLBACK_USER_COMMAND: EXIT routine for command handling
    I_STRUCTURE_NAME: Internal output table structure name     
    IS_LAYOUT: List layout specifications 
    IT_FIELDCAT: Field catalog with field descriptions
    IT_EXCLUDING: Table of inactive function codes   
    IT_SPECIAL_GROUPS: Grouping fields for column selection
    IT_SORT: Sort criteria for first list display
    IT_FILTER: Filter criteria for first list output
    IS_SEL_HIDE     : Selection information modification
    I_DEFAULT:      Initial variant active/inactive logic
    I_SAVE: Variants can be saved
    IS_VARIANT     : Variant information
    IT_EVENTS: Table of events to perform  IT_EVENT_EXIT :  Standard fcode exit requests table 
    IS_PRINT: Print information
    IS_REPREP_ID: Initialization keys for Re/Re interface
    I_SCREEN_START_COLUMN: Coordinates for list in dialog box
    I_SCREEN_START_LINE: Coordinates for list in dialog box
    I_SCREEN_END_COLUMN: Coordinates for list in dialog box        
    I_SCREEN_END_LINE: Coordinates for list

  • Change output format of  MC45,key usage value report to ALV format?

    Can someone please help me to change the change the Output of MC45 report to ALV format?
    Please help!!!
    Thanks!!!
    Owais

    I know i have to create a copy of MC45 to some z program but afterwards I am not sure where to look for to change the output format.
    Our ababper is extremely busy so i wanted to do litle bit of chnages by myself. I do have couple of years of java experience several years back, I thought i could help our abaper and learn myself little bit also.
    Thanks!!!
    Owais

  • Session variable usage in report title

    Is there a way to add session variable s_x in the report's title text?
    What is the correct syntax?

    Hi,
    I tried using @{biServer.variables['NQ_SESSION.varname']} in the narrative view and it seems to working fine and showing value without any decimals.
    You can try below:
    Write this statement - @{biServer.variables['NQ_SESSION.varname']} in the column fx. Say its the first column.
    Then, in your narrative view, write as below and set the no. of rows to 1.
    Top @1 Products
    This should ideally work fine.
    Thanks

  • Need to find out the usage of report

    Hi,
    I have published few reports in infoview. Need to find who all are accessing these reports & when.
    Can somebody help me?
    Thanks

    I would recommend to take a look at the admin guide
    http://help.sap.com/businessobject/product_guides/boexir31SP3/en/xi31_sp3_bip_admin_en.pdf
    Check the Managing auditing and Auditing reports sections.
    Regards,
    Stratos

Maybe you are looking for