User exit for infotype 2002
Hi ,
The requirement is making the WBS Element field mandatory ONLY for infotype 2002 cost assignment pop up in pa30.Is this any user exit check.
regards,
srinivas
Hi srinivasarao,
1. Enhancement name is PBAS0001.
2. Inside this FM is
EXIT_SAPFP50M_002
(for checking while saving)
regards,
amit m.
Similar Messages
-
Need Fcode in User Exit For Infotype
Hi,
I am writing a User exit for Infotype 0002 at Customers Site. I need Fcode to realize a specific logic. I am using the exit PBAS0001 for this purpose. can anyone tell me how to I get Fcode so that I can use it in the code ?
Regards,
SumaHi Suma,
sorry that i posted the false BAdI.
You have to use HRPAD00INFTY. That is for PA.
The BAdI HRBAS00INFTY is for PD/OM.
Regards
Bernd
But there is no paramter ok_code
Message was edited by:
Bernd Köhn -
i want o find out user exit for infotype 21 for the time and Absences plsea help me out
>
SANDEEP JADHAV wrote:
> Not working man , when i used infotype 21 and using subtype i am getting " Creating Absences " screen
> now i am entering time and Absences hours when i save the entries , now on that spot i want to find out user exit but i am unable to get it
>
> Please help me out
You meant infotype 2001, right? the User exit EXIT_SAPFP50M_002 works perfect or you could try the AFTER_INPUT method of the BAdI HRPAD00INFTY
~Suresh -
How to find the user exit for infotype 2013 ?
Hi All,
How to find the user exit in infotype 2013? i want to change the drop down list default value in infotype 2013.
Thanks,
Srikanth Preward points if useful
User exit name is PBAS0001.
code should be written in ZXPADU01 for PBO
ZXPADU02 for PAI. -
Hi,
In infotype 0045 (loans) there is a field for Intrest rate on the loan..as of now this field is a drop down...is it possible through some user-exit to change the type of the field from drop down to input field so that user can enter the intrest rate manually
awaiting your reply and thanks in advance
regards
Sai easwarHRPBAS01 User Exit for HR Master Data
HRPC0001 HR: PC download authorization
HRRPAI01 User exit for FB HR_ENTRY_DATE and HR_LE
PARA0001 Enhancement for Determining the Number o
PARA0002 Enhancement for Calculating Annual Salar
PBASRP01 PA: User exit distributed reporting
PBAS0001 PA: Pers.Admin./Recruitment: Default val
PBAS0001 PA: Pers.Admin./Recruitment: Default val
PBAS0002 PA: Enhancements for Personnel Administr
BADI BADI_PERSONID_EXT SAPMP50A Dynamic call
BADI EXIT_NAME SAPLHRBAS00UTILITIES/LHRBAS00U Dynamic call
these are the available exit here!!
gunjan -
Hi,
I have created two custom fields on infotype 8, i need populate on fied with base salaryBonus(from infotyp 14) and the other field should be the total of all line items on Infotype 8 ( Base salary shift differentials(permiums).
In order to do this, i searching for user exit , can anyone help me in doing this ..please
Thanks
KisuHi,
I looks into the exit.It seems it is doesnt get tigger while going through the PA40.I dont know is it possible or not but I need to do while going through the actions. when the user in pa40 goes through some actions and reaches infotype 8 and enters and the values and press enters ,at this moment I need to find the Exit that gets tiggers and calculates the values and populates the custom fields on 0008.
I would like to know is it possible to do so..?
Thanks
Kisu -
Hi,
I want userexit or BADI for Infotype 008. my requirement is i want to throw error if the user enters basic pay more than 15000 based on payscale type.
Any one send me the solution .
Regards,
SrinathYou can also create an enhancement if there is no BADI or userexit available. Just check the implicit enhancement options of that screen.
E.g. There is one module CHECK_ANSAL which is executed if there was a change to the salary. In that module routine CHECK_ANSAL is called. In that routine right at the beginning and at the end there are two enhancement points where you could plug in whatever code you need.
To check if a form has any enhancement points go to menu option PROGRAM - ENHANCE. Then choose menu EDIT - ENHANCEMENT OPERATION - SHOW IMPLICIT ENHANCEMENT OPTIONS.
Select the main report which is MP00080 and set the cursor on the line where you can see lots of """""""""""""""""""""""""""""""""""""'
Go to menu EDIT - ENHANCEMENT OPERATION -CREATE and that will allow you to create an enhancement in the code where you can then plug in whatever code you need. This code will always be executed whenever that module is called.
Note that this is not a modification, just see it as a kind of user exit where you have access to all the variables the standard routine has access to.
Hope that helps,
Michael -
User exit for Infotype 0102 - Grevience
Hi all,
I have a requirement where i have to put a check on infotype 0102 - greivence NA through user exit EXIT_SAPFP50M_002 .
The check is that if the user enters a personnel number , grievence number and a stage for which the record alreday exist in the table for the same personnel number , then system should pp up an error message.
I wrote the below code in EXIT_SAPFP50M_002 :-
data : i0102 like p0102 occurs 3 with header line,
begin of fs2,
pernr like p0102-pernr, grnum like p0102-grnum, grstg like p0102-grstg,
end of fs2.
CASE INNNN-INFTY.
WHEN '0102'.
MOVE INNNN TO I0102.
LOOP AT SCREEN.
SELECT PERNR GRNUM GRSTG FROM PA0102 INTO corresponding fields of fs2 WHERE PERNR = I0102-PERNR.
IF fs2-GRNUM = I0102-GRNUM ANd fs2-GRSTG = I0102-GRSTG.
MESSAGE 'A record already exist for selected combination of Grievence Number and Stage' type 'e'.
endif.
ENDLOOP.
ENDCASE.
Here system is throwing an error as " i0102 and innnn are not mutually convertible".
I tried to use a metod :
<b>cl_hr_pnnnn_type_cast=>prelp_to_pnnnn</b>
but still same error :
call method cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
exporting
prelp = innnn
importing
pnnnn = i0102.
MOVE INNNN TO I0102.
LOOP AT SCREEN.
SELECT PERNR GRNUM GRSTG FROM PA0102 INTO corresponding fields of fs2 WHERE PERNR = I0102-PERNR.
IF fs2-GRNUM = I0102-GRNUM ANd fs2-GRSTG = I0102-GRSTG.
MESSAGE 'A record already exist for selected combination of Grievence Number and Stage' type 'e'.
endif.
ENDLOOP.
Please suggest what to do.
Thanks and regards
RibhuHello Ribhu
Perhaps the following coding may be useful:
* define local data
DATA:
ls_p0102 TYPE p0102,
fs2 TYPE pa0102.
CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
EXPORTING
prelp = innnn
IMPORTING
pnnnn = ls_p0102.
" LOOP AT SCREEN. " ???
SELECT pernr grnum grstg FROM pa0102
INTO CORRESPONDING FIELDS OF fs2
WHERE pernr = ls_p0102-pernr.
EXIT.
ENDSELECT.
IF ( fs2-grnum = ls_p0102-grnum AND
fs2-grstg = ls_p0102-grstg ).
MESSAGE e398(00) WITH text-err
RAISING error_occured.
ENDIF.
" ENDLOOP. " ???
Regards
Uwe -
Hello Experts,
Please can anybody advise about the available user exits or includes for Infotype 8?
Many thanks,
Regards,
Anjali.Hi Anjali,
User exits in PA30-
More relevant for IT0008:
PARA0001
PARA0002
PBAS0001
PBAS0002
HRPBAS0001
Less relevant:
HRPC0001
HRRPAI01
PBASRP01
Regards,
Dilek -
Hi,
for specific country employees I want to add new field on basic pay screen to calculate new annnual salary based on some customer rules using uer exit. How shall i go about this?Hello
For that you can access the P0008 structure in the PBO of your Z program generated, based on which you can do the calculation. Or else you can access the P0008 from the call stack of your program run.
Also, you can use the exit ZXPADU02 which gets triggered for all the infotype. But put a check on IT0008 for your requirement.
- Ranganath -
Hi,
I have the requirement to change the deduction date( from/to date) 3 months ahead
of the start date and enddate whenever the user enter it.
pls help me out with the issue .Hello,
Can anybody help me out with the above scenario ?????????/ -
Hi all,
Pls kindly help me to find out the user exit for infotype 0185. I want to check the value when saving a record.
Thanks,
QuanglvHi,
1. Go to transaction CMOD
2. Selct project PBAS0001
3. View components
4. Choose an exit
5. Click EXIT_SAPFP50M_002
6. This exit contains one include. Double click "ZXPADU02". The program ZXPADU02 runs executed every time PA30 or PA20 is executed.
7. Add in ZXPADU02 this code for example:
IF innnn-infty = '0105'.
add sone useful code specifically for it0105here
ENDIF.
good luck -
HR-ABAP-want user exit for pa30 for creation 2001 infotype for sick leave
Hi ALL,
My requirement like, whenever I try to create a sick leave through PA30 Tcode for infotype 2001 then the has to be trigger like, if the personnel joing date will be from Feb-Dec any date of the year then, the SL will be valid for next year Jan.
Ex; Todya I am creating SL on 2001 infotype. then the condition will
If joining date not Jan 2007 then,
Leave will be valid for next year Jan 2008.
So, let me know is there any user exit for this.
Thanks In advance.
J.PFind myself
-
We have a custom Infotype 9001.
I need to do some validations for this Infotype.How do I find a user-exit for this.
We are on ECC6.0.
Thanks
KiranHi,
I have the same requirement. Can you please help me out. How to find user exit or badi or Enhancement Spot for the custom infotype.
Thanks & Regards,
Prabu -
How to maintian user exit for a wage type
Hello Experts,
I would like to maintain a user exit for a particular wage type in infotype 14. As the business rules of the client are specific...So, please help me with ur views...
thanksHi
Check the LTA , I am not sure but still you can configure for the medical also .
Now to lapse is again a issue.
Well i think you can do it .
Now how is the main thing , suppose i can give you one example you can get the better way your own.
Now How you are going to put the values from IT 90--- to 15 are you going to put directly ?
Now there is std prog pc00_mXX_remc / remp now check with this program which is suitable for you and add the codings whatever required in the the customized program which you using to put the values to IT15 .
You got it now.
It can be done .
All the best.
Manoj Shakya.
<b>Reminder : Points should be given on answers.</b>
Maybe you are looking for
-
Getting lost wading through the plethora of information available, so any direct pointers to information that directly addresses the following would be appreciated, in addition to any direct answers of course! Consider a multiple BW instance, with a
-
How i conect my ipod nano to wi fii
How conect my ipod nano to wi fii
-
Which driver to use to print to a dot matrix printer?
All- Hi, we are using Adobe Output Designer 5.7 to create invoice templates. We use a custom application that uses Adobe Output Central Server (5.6) to create invoices and print them to a network printer. We are about to do a new release in Chile,
-
Updates will not load????
When the software update appears on the screen I click on the ones I want, it downloads, prepares to install, says it is installing then after a short time a box pops up says: *The update "Security Update 2008-009 (PowerPC)" can't be installed.* Sorr
-
Airport Fast on Windows than Mac
Airport Express / PBG4 1.5ghz 1GB RAM OsX 10.4.11 / HP Compaq Pentium 4 WIndows XP 512MB RAM Both running Safari 3. I find that the PC is much faster on my ADSL conection via Airport & Ethernet than my PowerBook G4. Is there any particular reason for