Hi,
Can anyone guide me on configuring leave and travel workflow and UWL connectors.
We have deployed ESS/MSS .
HR is configured in SAP ECC. Workflows are configured. I want to integrate to UWL.
I am very new to UWL , so i need steps from start to end like connectors creation and RFC creations etc
Thanking You,
Jessi

For a good overview I suggest you [Look at this|http://www.google.com.au/url?sa=t&source=web&cd=1&ved=0CBQQFjAA&url=https%3A%2F%2Fcw.sdn.sap.com%2Fcw%2Fservlet%2FJiveServlet%2Fdownload%2F113876-4-51769%2FTop10RecommendationsUWL.pdf&ei=lSe2TOeQIY-yvgOdkICTCQ&usg=AFQjCNGLZGdkgGlY6T3CZOtfiYTJEIvA-A&sig2=MbZCgJbLaXEkL4ihq-ZYBw]
The help guide tells you how to do the basic configuration: http://help.sap.com/saphelp_nw70ehp1/helpdata/en/39/a1bb5c4c0d4ab4a417e87ef35f1efa/frameset.htm
BRgds,
Simon

Similar Messages

  • SAP Cloud for Travel and Expense r1405

    SAP Cloud Customer Engagement sent notification emails today, May 13th, notifying existing SAP Cloud for Travel and Expense customers of the planned upgrade dates for release 1405.  Test tenant upgrades are planned for May 23-26 and production tenant upgrades are planned for June 6-9.
    Release to new customers (RTC) is planned for May 23.  The What's New documentation will be published at http://help.sap.com/travel-od once RTC occurs.
    A customer infosession about the upcoming release is planned for May 21 at 5-6 PM CET.  Details regarding how Cloud for T&E administrators can join the session were included in the upgrade notification email.

    Hi,
    There is a separate community for Cloud Applications Studio.  Please post your question there.
    Thank you,
    Angi

  • I will be buying the new IMac 27 inch in December. Would like input on the best configuration for photographic and possibly video processing-dream machine!

    I will be buying an IMac 27 inch in December. What is the best configuration for photo and possibly video processing.Does one need a Mac Pro? Dream machine!

    Just to explain what I just wrote to Laundry Bleach:
    Why is there no iDVD on my new Mac?
    https://discussions.apple.com/docs/DOC-3673
    UPDATE & ADDENDUM:
    But even though you can still buy iLife 11 that includes iDVD 7 from Amazon, Apple now make it difficult to install:
    Poster jhb21939 posted this in another thread:
    “when I attempted to load iDVD into a new iMac. A notice came up on the screen stating that the 'Authorisation Licence' had expired on 25 March this year (2012).
    I contacted the Apple support team and eventually, I was told that the Licence had been withdrawn and could no longer be used.”
    In other words Apple are now so adamant that we don’t use iDVD that they have tried to make it impossible to install.
    In response, Old Toad posted this solution:
    “You can still use it one all of your Macs.  If you get an invalid certificate message just set your Mac's clock to sometime before early 2011 and run the installer.  After you're done reset the time back to the correct time.” He added this comment:
    “It began after iDVD and iWeb were discontued and they were dropped from the Apple Store. All I can think of is the certificate was set to expire after a certain time period after the intitial iLife disc was released.
    I've been able to use the installer even without setting back the date.  I just clicked on the Continue button and it would work as expected.  For some it would not continue unless the date was set back.”
    The latest anorexic iMacs just announced do not even include a CD drive! Proof positive that Apple virtually prohibit the use of DVDs - although the newly announced Mac Minis do include a Superdrive.
    Yet, they still include iMovie! Heaven alone knows or understands what you are supposed to do with your newly edited masterpiece - except make a low quality version for YouTube?

  • I play music from my iPhone via Bluetooth on the car radio. The phone also connects over the radio. Can I turn off Bluetooth for phone and leave it on for music?

    I play music from my iPhone via Bluetooth on the car radio. The phone also connects over the radio. Can I turn off Bluetooth for phone and leave it on for music?

    I haven't tried it yet, but I believe this would disconnect Bluetooth for both the phone and music. I have a 2013 Hyundai Sonata if this will help.

  • Substitution SBWP turned off for Travel and Entertainment

    Dear SAP Experts,
    Is there a way to shut the substitution functionality down alltogether for Travel and Entertainment?
    Can substitution be restricted to certain SAP areas (i.e Invoice approvals)?
    Can substitution in T&E be restricted by security roles not restricting in the same time substitution in other areas (AP approvals)?
    I would be very thankful for help on this.
    Best regards,
    Robert

    Thank you!
    I have an Imac 21,5¨   2,7HGz   Intel core i5    from 2011.... Can I change the PRAM battery?
    I have the original box and I plan to keep it there.

  • Error in UWL configuration for MSS in portal..

    HI,
    I want to configure UWL in portal so that I can see/approve  leave in UWL in MSS. Please let me know how to configure the same.
    When I am trying to configure the UWL in system admin> system configuration> Univerasal Worklist Administration, under that i clicked in new button to add my R/3 system, in that popup i mentioned my system alias name of R/3 system and connector as Webflow connector and remaining field i kept as empty and i clicked on save button after that when i click on Register button OR Register item type for all system than I am getting the following error, please let me know what the  issue is ?
    Error is:
    Errors:
    System SandBoxCLNT300: Wed Mar 16 09:18:38 IST 2011
    (Connector) :com.sap.netweaver.bc.uwl.connect.ConnectorException:Wed Mar 16 09:18:38 IST 2011
    (Connector) :com.sap.portal.connectivity.destinations.PortalDestinationsServiceException:User is missing credentials for connecting to alias SandBoxCLNT300. Contact your system administrator.
    SandBoxCLNT300 is the system alias of system I have created for R/3. in that system object I am using logon ticket.
    Also when i try to test that system , SAP Web AS Connection  AND  ITS Connection connection are tested properly with green tick but the third parameter  Test Connection with Connector is failing and the error is
    Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    Also the transaction iview i created using this system object is coming absolutely proper, than why Test Connection with Connector is failing , please let me know , might be UWL issue is related to this one..
    Thanks

    Please first let us know if you have done the configuration as per
    the Note 779075, Please do this and re register the work items and
    let us know.
    Make
    Check the configuration of SAP_WebDynpro_XSS
    Here is the help documentation:
    http://help.sap.com/saphelp_nw70/helpdata/en/92
    /a88931f2dd4631b9e8d530697d89c9/content.htm
    in regards to this parameter.
    IF the LeaveRequestApprover application is deployed on the SAP_Local
    System, you needed the system alias of SAP_LocalSystem in the
    Webdynpro Launch System value.  With this setting when the user
    manager clicks on the item, it will work fine.
    the system SAP_Webdynrpo_XSS should have maintained the WAS properties
    with the port of the portal. This is for normal working for
    Leave request
    "Mapping Logical Systems" in the following documentation:
    http://help.sap.com/SAPHELP_NW04S/helpdata/EN/2a/7a754297fdd142e10000000
    a1550b0/content.htm
    and the "sap-wd-arfc-useSys" bullet point in the following
    documentation:
    http://help.sap.com/saphelp_sm32/helpdata/en/f4/651741f163f023e10000000a
    155106/content.htm
    See in bold where it mentions that "The prerequisite for this is that,
    in addition to the default JCo connections, you created the new logical
    system name with the Web Dynpro Content Administrator and configured it
    for the required SAP system." Meaning that there needs to be a JCO
    Connection for "SAP_R3_SelfServiceGenerics_MetaData" since these are
    the default JCo connections. In this case I kindly ask that you create
    the default metadata and model JCO connections for
    SAP_R3_SelfServiceGenerics and see if that resolves the issue.

  • UWL configuration for Federated Portals logging errors in defaultTrace

    Hi everyone,
    I've just finished configuring UWL for Guided Procedures on federated portals using the help provided in the links below:
    [https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/904ca240-63bc-2a10-1c98-de81b6a045bf|https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/904ca240-63bc-2a10-1c98-de81b6a045bf]
    [http://help.sap.com/saphelp_nw70/helpdata/EN/43/ef06a7860c7061e10000000a1553f6/content.htm|http://help.sap.com/saphelp_nw70/helpdata/EN/43/ef06a7860c7061e10000000a1553f6/content.htm]
    Everything is running very well except for the fact that exceptions for the GPsystem I created are showing up in the defaultTrace log. The message repeats itself several times:
    03/12/2009 , 15:56:12:234 , GPsystem    | ACCESS.ERROR        | null     |           | Permission=(com.sap.caf.eu.gp.model.permission.GPPermission GP.GET.WORKITEMS) , Error , /System/Security/Audit , com.sap.security.core.util.SecurityAudit , sap.com/cafeugpmodeleap , GPsystem
    These log traces repeat themselves so many times that they seem to be causing an unnecessary load on the system. Other that that, both the Guided Procedure and UWL are working perfectly. Does anyone have any idea as to why this might be happening?
    Thank you very much,
    Luis

    Hi
    UWL Configuration is not  proper so only this happening.
    Refer the [Link1|https://wiki.sdn.sap.com/wiki/x/IwBbAQ ] [Link2|https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/a3461636-0301-0010-3787-978f5ac8bd45] [Link3|http://help.sap.com/saphelp_nwce10/helpdata/en/05/fe8ef669674991a4205666694b9c85/content.htm] .
    Regards,
    Surjith

  • UWL configuration for decision step

    Hi!
    We are using the decision task for approving trips (TS200000118).
    We've to add a decision note as described in this forum (UserDecisionNote).
    How do I get the standard xml for this step to modify this.
    I just found the entries in the uwl.webflow:
    <ItemType name="uwl.task.webflow.decision.TS20000118.mandant086" connector="WebFlowConnector" defaultView="DefaultView" defaultAction="viewDetail" executionMode="default">
          <ItemTypeCriteria systemId="mandant086" externalType="TS20000118" connector="WebFlowConnector"/>
    </ItemType>
    Kind regards and thanks for any hints!
    Peter

    Hi Peter,
    As you are already aware of UWL supports a property called UserDecisionNote for the UserDecisionHandler action and can configure the XML file of UWL for this.
    For example:-
    Can add the following in UWL xml configuration file. And then upload the xml file.
    <ItemType name="uwl.task.webflow.decision.TS90100366.SAP_ECC_FINANCIALS.SAP_ECC_Financials" connector="WebFlowConnector" defaultView="DefaultView" defaultAction="viewDetail" executionMode="default">
    <ItemTypeCriteria systemId="mandant086" externalType="TS20000118" connector="WebFlowConnector"/>
    <Actions>
    <Action name="send" groupAction="yes" handler="UserDecisionHandler" returnToDetailViewAllowed="yes" launchInNewWindow="no">
    <Properties>
    <Property name="decisionKey" value="1"/>
    </Properties>
    <Descriptions default="send"/>
    </Action>
    <Action name="reject" groupAction="yes" handler="UserDecisionHandler" returnToDetailViewAllowed="yes" launchInNewWindow="no">
    <Properties>
    <Property name="UserDecisionNote" value="true"/>
    <Property name="decisionKey" value="2"/>
    </Properties>
    <Descriptions default="reject"/>
    </Action>
    </Actions>
    </ItemType>
    Please refer to [link|http://help.sap.com/saphelp_nw2004s/helpdata/en/7a/df014b037141ca9afc6433ed42b519/frameset.htm].
    Thanks
    Arun Singh

  • UWL Integration for Material and Customer Repositories

    Hello all,
    Has someone done the UWL Integration for Material or Customer repositories? Do we have to write own XML Configuration file for UWL and upload? or is that supplied by SAP somewherer for Material and Customer repositories?
    Any pointers in this direction are highly appreciated.
    Thanks
    Suman

    Hi Suman,
    You can create your UWL Configuration file through UWL Cofiguration file wizard.
    The path is navigate to System Administration  System Configuration   Universal Worklist – Administration.
    Under Universal Worklist Content Configuration select Click to configure item types and customize views using a wizard.
    Thanks
    Namrata

  • Oracle data guard configuration for primary and standby db_name

    I am working on configuring an active data guard for one primary DB and one standby DB. I have a few questions:
    1. Can I use different db_name, db_unique_name and instance_name for primary and standby. For example: primary(db_name, db_unique_name and instance_name)=chicago. When I create standby DB with Rman backup and copy of pfile and control file from primary DB or use Grid control to create standby database. Oracle document or Grid control all keep standby db_name=chicago. Only make standby db_unique_name and instance_name=boston. Due to my application system condition, I want to make db_name=boston, not keep it as the same as primary=chicago. Is this valid configuration?
    2. In primary datafiles, application system generate datafile name like this: hr_chicago_01.dbf, fn_chicago_01.dbf. When I move datafiles to standby server, if I plan to use db_name=boston for standby DB, can I rename datafiles as
    hr_boston_01.dbf, fn_boston_01.dbf? In this way, datafile name match up with db_name. but I will create standby log group and members on primary and standby identically. If in future switching over, DB will not have problems.
    3. If I don't use primary DB backup. Instead, I copy all datafiles, redo_log files (no control files) to standby. Then "alter database backup controlfile to trace" from promary and also " create pfile='/xxx/initSTANDBY.ora' from primary. Then modify init.ora and controlfile. Then run control.sql to bring standby DB up. After that, configure redo log shipping and apply with data guard or SQL. Is this a acceptable way to create physical standby DB?
    Please advise your comments. Thanks in advance.

    I want to make db_name=boston, not keep it as the same as primary=chicago. Is this valid configuration?NO. DB_NAME must be the same ("chicago") at both sites. The Standby will be using a different DB_UNIQUE_NAME (e.g. "boston") and can be using a different Instance name / SID (e.g. "boston").
    can I rename datafiles Yes. The database file names can be changed.
    If I don't use primary DB backup. Instead, I copy all datafiles, redo_log files (no control files) to standbyWhat is the difference between the first sentence (a backup of the primary) and the second sentence (a copy of the primary) ? A Copy is a backup.
    Are you intending to differentiate between an RMAN Backup and a User-Managed (aka "scripted") backup ?
    Normally, for DataGuard, tou can use non-RMAN methods to copy the database but there's no value add in this.
    You'd still have to setup DataGuard ! (and I wonder if you'd have complications setting up Active DataGuard).
    But remember that you MUST create the Standby controlfile from the Primary and copy it over to your Standby -- particularly as you are planning to use DataGuard. This is not created by 'alter database backup controlfile to trace' , but by 'ALTER DATABASE CREATE STANDBY CONTROLFILE AS 'filename''
    Hemant K Chitale

  • R/3 configuration for 0SD_C01 and 2LIS_01_S001

    Hi guys,
    I have activated the infocube 0SD_C01, the complete flow. I created an infopackage for its infosource 2LIS_01_S001 and made an extraction. I got an error with a delta initialization and with a full upload I got that there is no that data in R/3. I’m currently using BI 7.0 and R/3 ECC.
    Is there something I need to do first in R/3, some kind of configuration for that datasource? They told me for the datasources 2LIS* used the transaction LBWE, but I don’t see 2LIS_01_S001 on that transaction.
    What do I need to do in R/3, in order to do extractions? Does someone have a manual for this Datasource/Infosource that would like to share? My email is [email protected]
    Thanks a lot
    Vic

    Hi,
    There is no LO datasource , you have to use LIS ..i.e, 2LIS_01_S001.
    I hope you know the steps to activate and load data into BW using LIS.
    Steps are as follows:
    1) Activating LIS update - goto OMO1 transaction code
    In the Updating – Info Structures(S001) - double-click the Updating radio button for Info structure S001.
    In the Parameters dialog box select Synchronous updating and choose ok.
    2) Goto OLI7 Transaction code - run the statistical update.
    3) Goto OLIX transaction code - setup version &( will be copied to actual version 000 for reporting
    4)Go back to OMO1 do deactive the LIS Update, check radio button to "No Update"
    5)Now goto LBW0 and choose option "Deactivate" Delta updating in LIS.
    6) In BW, Replicate DataSource, and run info Package with Initilization.
    7) Now again in R/3 we need to "Activate" Delta option from transaction code LBW0.
    8) and last step is to goto OMO1 to activate LIS Update to Synchronous updating and save.
    From now on you can run your Delta Infopackage
    Hareesh

  • PC configuration for Premiere and AE (CC)

    Hallo everybody!
    I'm an Italian filmaker and I'm going to buy a new workstation but I don't know anything about hardware.
    I use Premiere for editing and AE for compositin and motion graphics.
    A couple of years ago a friend of mine suggested me this HW configuration:
    MSI Z87-G43 z87 4*DDr3 Gen 3.0 sk1150 Vga/Hdmi ATX
    Corsair 16GB Kit 2*8GB DDR-1600 CMZ16GX3M2A1600C10 XMS3-12800 serie Vengeance CAS10
    Inte Core i7 4770 3.40GHz Cache 6MB Haswell LGA1150 BOX
    Samsung MZ-7PD256BW SSD 256GB 840PRO SataIII 540/520MB/s 100K IOPS OE
    WesternDigital HDD 1TB Enterprose RE4 64Mb 7200 rpm SataII
    Zalman CNPS9900MAXBLUE Silenziosa Led Blue sk1155/1156/1366/775/AMD
    Corsair Carbide 300R Middletower No-Power ATX
    LG BH16NS40 Bluray Writer 10x 3D
    Digitus 3.5" Card reader USB 2.0 port
    Logitech keyboard K120 Business
    Corsair 750 CX 750watt EPS Pci-E PFC active 80+ Bronze
    MSI NVIDIA GeForce GTX770 OC Gaming TF IV 2GB 256bit Dvi/Hdmi/DP PCI-E 3.0
    Budget: almost 2000€
    Can anyone help me finding a new configuration with the same budget but with new-recent hw components?

    Double the RAM to 32 GB at a minimum.
    Use a full size case, not a mid-size.  You'll get better air circulation and have room for expansion.
    Add a couple more hard drives.
    Get a 850w gold power supply.

  • System configuration for ITS and for BSP

    Hi,
    I´m looking for the parameters needed in a system to connect to an ITS and also to BSP.
    I have created one system to be able to connect to ITS and another one to be able con connect to BSP, both of type SAP Load Balancing system.
    The system I created to connect to ITS has the following configuration I entered:
    Connector:
    SAP Client = 350
    Internet Transaction Server (ITS)
    ITS Description = myDescription
    ITS Host Name = myhostname:port
    ITS Path = /sap/bc/gui/sap/its/webgui
    ITS Protocol = http
    Thats it that´s the only configuration I´ve made.
    For the BSP system I entered:
    Connector:
    SAP Client = 800
    Web Application Server (Web AS):
    Web AS Description = myDescription
    Web AS Host Name = myhostname:port
    Web AS Path = /sap/bc/bsp/sap
    Web AS Protocol = http
    My question is this, is this configutation enough?,
    It is working fine with this configuration but I´ve seen some other information where they fill more parameters in the  connector section, would this extra parameters in the connector section help in any way or they will just simply be ignored?, We will be using Web Dispatcher for both.
    does somebody knows the answer? Is there some documentation on this?
    Thanx in Advanced!!
    Kind Regards,
    Gerardo J

    The connector properties are only required if you are planning on utilizing the SAP connector to connect to your backend system.
    What you have configured so far should suffice for ITS and BSP applications. I hope you have configured the system aliases already.
    Have a look at the following links for some additional inputs:
    http://wiki.sdn.sap.com/wiki/display/EP/MinimumSettingsforaSystem
    http://wiki.sdn.sap.com/wiki/display/EP/HowtoCreateSystemObjectinthePortalforConnectingtoSAPbackend+System
    - Shanti

  • FI 6248 Pre Licenced ports(1-12) configuration for Ethernet and FC

    Hello UCS Gurus,
    I am setting up a new UCS lab with 1 5108 Chassis,pair of FI 6248 and FEX2104.My query about the FI 6248 is that
    1) I have 12 pre-licenced Unified ports on my FI 6248 and I need to configure 1-10 for Ethernet and 11th/12th for FC port.,,,,Is it a valid configuration?
    2) If yes tomorrow if I buy the licence for the remaining ports 13-32. Can i continue using them as Ethernet and FC ports in alternate.I know
    Ethernet ports/FC ports must be grouped together in a block and they should end with even numbered port.
    Looking for your response on this....

    Hello Padma,
    I am stucked at a point of configuration on my lab and need your valuable advice.
    I have 8 SFP-H10GB-CU3M and 4 Nos SFP-10G-SR in my BOM.
    My confusion is I have to accomodate these SFPs only in my currect environment.I cant wait for the entire process of re-ordering new SFPs.
    So I will have to split SFPs between the pair of FIs and IOMs.
    So is it that I am short of SFPs? because my understanding says that I will be needing atleast 4 SFPs(Cu) on both FIs.
    So for FI1----> 2 SFPs(Cu) for Server ports,2 SFPs(Cu) for Uplink Ethernet ports
    for FI2------> 2 SFPs(Cu) for Server ports,2 SFPs(Cu) for Uplink Ethernet ports
    That means all my 8 SFP-H10GB-CU3M are exhausted.
    I dont have more SFPs to connect to my 2104 IO Modules.Please suggest me some workaround.I am in process of creating a lab so performance and bandwidth is not an issue for me.
    Regards
    Deepak

  • Encoding configuration for signed and encrypted emails

    I have a 8820 device (no BES server)  - I have certificates downloaded and trust on the device.  I can attach the requisite certificates to the message, but I do not have the option to select signing or encrypting encoding.  the menu does not give me this option.  I have the S/MIME package installed.  Any thoughts / pointers?

    The S/MIME support package is only supported with a BES. You might try Djigzo for BlackBerry. Djigzo for BlackBerry is an add-on to the Djigzo Email Encryption Gateway which can be used to send and receive S/MIME digitally signed and encrypted email from a BlackBerry smartphone. An installation of the Djigzo gateway is required.
    Djigzo for BlackBerry and the Djigzo gateway is open source and can be freely used.
    For more information see www.djigzo.com
    Djigzo open source email encryption

Maybe you are looking for