Validating that delta links are used

Hi there
In our current project, we have a number of workbenches which have to be delivered as part of the Enterprise Portal solution. Each workbench comprises a number of roles that are merged in various manners to create the navigation.
The iviews that are assigned to the roles are only created once, and are supposed to be assigned to the roles using delta links.
However, I have found in the last few days that some iviews have not been linked with delta-link as changing the source files hasn't necessarily changed the iview in the role.
Is there a relatively painless way of checking that the iviews are inserted as delta-links and not copies?
I have thought about going through each role and checking either with the Delta Link Tracer or just re-assigning the  iview as delta-link, but that could be a lengthy process, and I am looking for something a bit easier than that.
Any ideas?
Cheers,
Andrew

Hi Andrew,
If you are on NW04 SP13 or higher, there is an easy way out. Use the support platform to check your broken delta links.
Check these
Support Platform II: Reports for Portal Administrators
and
https://www.sdn.sap.com/irj/sdn/developerareas/?rid=/webcontent/uuid/a232f867-0c01-0010-fd88-f82e0e264bb5
Akhilesh

Similar Messages

  • Anyone know how Delta Links are stored in a Clustered environment?

    We have a situation where we have a clustered EP6 production environment with 4 servers in the load balancer.
    However, we've found that on just one of the servers the Delta Link between one of our roles and its only workset is missing.
    Wanted to know if anyone could explain how these delta links are stored and/or what happens during transport import in a clustered environment (e.g. are components deployed only to the central database or deployed to each server in the cluster)?
    Thanks for any help/advice on this you can provide.

    Hi Steve,
    The delta links are stored in the PCD which is common for all nodes in the cluster (there is only one database).
    When importing portal content to a cluster it is stored in two locations: one in on the central instance and the other one is locally on the specific node to which it was imported.
    All other nodes are informed that there is a new content but will only upload it locally on demand (only when a user is calling this content).
    Please award points if you find this answer helpful.
    Regards,
    Amit.

  • TS1363 When I sync my ipod all goes well until I try to eject then it says that other systems are using files on the ipod. Nothing else is running and when I physically eject the ipod hasnt synched....ideas anyone?!

    When I sync my ipod all goes well until I try to eject then it says that other systems are using files on the ipod.
    Nothing else is running.
    The only way I can eject is to do so manually, when I do I then find the ipod hasnt synched.
    Any ideas?

    Here is what worked for me:
      My usb hub, being usb2, was too fast. I moved the wire to a usb port directory on my pc. That is a usb1 port which is slow enough to run your snyc.

  • Is it true that while you are using someone's wifi, that they can see whatever your doing that involves the Internet?

    Suppose you are using wifi. For example, I use my dads wifi, can he see what I am doing on my iPod when I use the Internet/wifi?

    Yes it is possible if he has installed the appropriate monitoring software.

  • I send emial with links and anchors and when someone else forwards that, the links are converted to http addresses that go to gmail!

    I send out an email with many "internal" links, that is, links that go to anchors within the email. someone else picks up the email and forwards it to others. Now, instead of looking like this:
    #GHNNCEP
    the link looks like this:
    https://mail.google.com/mail/u/0/#14c1630a55126b2f_GHNNCEP
    and of course does not work as intended.
    Huh?
    Thx.

    I need to refer to sections within the email, not external links. I thought anchors was the way to go for that. Have you something different?
    Thx.

  • Is there something, like the SD card for example, that you can remove from your phone and leave somewhere so that when people are using Find My Friends, they think you're somewhere else?

    It's unavoidable - but I don't like being tracked. Is there a way to make everyone think I'm somewhere when I'm not?

    Delete the Find My Friends app. Don't give anyone your Apple ID password as if they had that, they could use Find My iPhone to track your phone. Don't let social media services (twitter, Facebook, Instagram) have access to your location services.
    If you are on an cell phone account that is controlled by someone else (e.g. parents) note that they may be able to avail themselves of carrier services to track your phone. In order to avoid being tracked that way, you would, as Bonanaza888 noted, you'ld need to put your phone in Airplane mode or turn it off.

  • Delta-links not updated

    Hi
    We have created some delta-links between uploaded roles, but the delta-links are not updated when changes are made to the source object.
    How are delta-links updated? Is it a service running in intervals? If yes, how can I access the service to see if it is running, restart it or change the interval?
    Any help is appreciated
    Kind regards
    Morten Ellgaard

    We are on SPS13, and I think something has changed. The documentation only refers to remote delta-links, but we do not use federated portal. I am pretty shure that I have seen a delta-link update service in a previous version, but now it is gone / I can't find it.

  • Content Transport with Remote Delta Links

    Hi Folks,
    we using Federated Portal mechanism for building ESS scenarios (producer) in an SAP Intranet Portal (consumer).
    The Federation integration works fine (with known ......), we are using remote delta links. Now we try to transport from the development consumer portal (connected to the development producer portal) the content with normal transport packages to the consumer test portal (connected with the producer test portal). But the remote delta links from the consumer development portal are not transported to the consumer test portal !
    We can´t use the same producer Alias like describe in http://help.sap.com/saphelp_nw04s/helpdata/de/43/2280c70d21400ee10000000a11466f/content.htm
    why the producer portal connected to the consumer test portal is the producer test portal! This have different alias names, because these are different portals !
    Is there any possibility to use the transport for remote delta links via using different producer portals ?
    THX
    mario

    Hi Lakshmi,
    Have you updated your consumer and producer with the latest patches from SMP?
    Please switch on the traces of the following components to DEBUG severity in the visual admin, re-run the scenario and look for an error in the default trace of the server and dispatcher (consumer and producer).
    Dispatcher -> Services -> Log configurator -> Locations (Tab) and then navigate to :com -> sap -> engine -> services -> rmi_p4
    and
    Server -> Services -> Log configurator -> Locations(Tab) and then navigate to :com -> sap -> portal -> fpn -> persistancy , com -> sap -> portal -> fpn -> transport
    Regards,
    Oren

  • My saved messages are using a lot of memory.  How do I free up the memory?

    My saved imessages are using a lot of memory (3.1GB) on my iphone.  How can I free up the memory?

    This is when I go to "usage" and it lists all of the memory used by certain apps.  Messages is the largest, and I swipe to the left to open it and it says that "saved messages" are using all of it.  There is no option to do anything at this screen.

  • Reverting delta links?

    Hi All,
       I made a delta link of an standard SAP PCD object(X) into my local workspace (Y) and then edited only one property of that delta linked object (Y). so now i could see a sybmol "#" beside that delta linked object(Y). which means that there is some change from the original one (X).Now I want to revert this to the properties of original. I changed that property back to the orignal. but still i see "#" beside my PCD object.
      Is there soem tool available such as delta link comparator..which compares two delta link objects and show the differences between them..i.e. properties changed from the original
    Thank you

    I think what you want is to reset the Property
    If you want to do so, you have <b>to "expand" the Property</b> (small black triangle at the left of a Property on the Properties Panel) and then <b>click on the Reset button</b>. This will return the Property to the source value (and remove the "#" symbol)
    You can also do the same for the entire object with the "Reset Node" button
    As far as I know, there is no option to do it 'massively' in the Multiple Property Replacement functionality.
    Let me know if you find it !

  • Linked servers:Using 64 and 32 bit ODBC providers concurrently

    I have a very odd problem that I hope someone can help me with.  I have a 64 bit odbc MySQL driver.  Unfortunately, although I can connect to the data source from the control panel, the linked server cannot connect to the MYSQL data source.  The
    funny thing is that other linked servers (using the same odbc driver) have no problem connecting to their respective hosts.  The problem seems seems to be between the 64 bit linked server and the host (a shoretel IP phone database that runs on top of
    windows).  I know that the 32 bit driver used to work, but when I rebuilt the server to 64 rather than 32 bit the linked server failed.  What I am trying to do is to use both 64 bit driver and 32 bit driver concurrently (I have installed the 32 bit
    version using the WOW 32 bit odbc tool, but because the SSMS provider dialog only allows me to use the 64 bit system dsn.  I am wondering if I can get the 32 bit version to work as well using a user rather than system dsn.  Is this possible?  I
    can send screenshots of the problem if needed.  Thanks in advance for any advice you can offer.

    What I am trying to do is to use both 64 bit driver and 32 bit driver concurrently
    You can not. You can only use provider of the same 32/64 bit architecture as the SQL Server have.
    Olaf Helper
    [ Blog] [ Xing] [ MVP]

  • HT204053 Apple offered to install iCloud, and I allowed it. Yet when I try to sign in to iCloud using my Apple ID email and pswrd--an ID that I've been using for YEARS--I'm given the message, "This Apple ID is valid but is not an iCloud account." What is

    To repeat my question, Apple offered to install iCloud, and I allowed it. Yet when I try to sign in to iCloud using my Apple ID email and pswrd--an ID that I've been using for YEARS--I'm given the message, "This Apple ID is valid but is not an iCloud account." What is going on?
    Everywhere I search on Apple's Support site says to sign in to iCloud using your "Apple ID," which I did. I've had my iTunes account for years (even migrated from the old AOL account system). It's the standard email+password that everyone is supposed to use.
    My main question is how can I have a valid Apple ID and not an iCloud account--if the two are supposed to be linked?
    Thank you for any help you can give me!
    tlj

    I've tried both. First, I tried on my pc, where iTunes had installed iCloud when it last updated. I have iTunes installed on this computer (and on my iPad and iPhone), but that wasn't the issue.
    So I went online, thinking I needed a separate iCloud Apple ID, but it prompted me for my current Apple ID and gave me the message about my ID being "valid" but not an iCloud account," which, lol, was what it had asked me to do in order to create one. I checked, and at least one other user is having the same issue. I'll attempt to copy/paste the Support request url: https://discussions.apple.com/thread/4430653?tstart=0
    Thank you for any help you can give.
    Trish

  • What can I do if all HTML links refresh site instead of redirecting properly (FF only, HTML 1.0 Strict valid, no plugins) just after using autocompleted url?

    I was testing a XHTML 1.0 Strict valid website on my localhost. It had URL "http://localhost/visaita/tictactoe/Web/index.php?item_id=8&game_password=73|55fc84c0c432ad625a901caaa13108aa&chat_code=74|50b3b60c8be203.98819772#.ULO2EnC23XQ". If I click in URL field between 8 and ?. Then pres shift + end and delete the rest of URL, I get a drop down of suggestions. Then I press arrow left in my keyboard - suggestions dissappear. I press enter and my URL is immediately reset to initial one (with all arguments) even though I wanted to delete them. Server receives all the arguments, so this is not the case of a back-end redirection (tested).
    The most interesting effect is that after such refresh ALL HTML LINKS stop working. They refresh page instead of redirecting. Even if I click on a link redirecting to another domain, page still gets refreshed and not redirected. I see it as an obvious and serious bug which happens in very special conditions.
    All FF plugins and add-ons disabled. Tested in safe mode as well. One interesting fact is that this page is opened by a redirect from another page (JavaScript performs redirect), but the page where error happens does not contain any JavaScript redirection code. Error console is also empty.
    During these redirects FireBug (when enabled) displays interesting stuff. It shows that request without arguments is pending infinitely while immediately after it another request is launched with all unwanted arguments.
    Another interesting fact is that page is using late polling AJAX technique (not sure whether it has any impact).
    It seems that it is some caching bug.

    Autocompleted URL does not seem to be related in order to provoke the bug. If I press Esc and then immediately press on links, they all work fine. Without pressing Esc, if long polling is in action, all links redirect the same page. Long polling request happens for no longer that 2 minutes and then there is a 1 second JS delay before the next one. If links are pressed between calls, they work fine.
    The strange thing though is that my friend has prepared a simple script which is generating a long polling request and has a link to Google. This test works, so I am trying to understand whether there is any additional factor which is causing the problem. Perhaps it can be due to having redirects and 2 simultaneous long polling requests at the same time. Doing my best to understand the problem. Not sure what is happening although I am quite sure that problem is caused by the FF browser somehow. Tested everything back and forth.

  • Basic Question on Copy and Delta link which one to use when?

    Hi
    Its basic question
    My understanding about copy and Delta link is
    Copy doesnot ahve direct relationship with source object (but it acts as a sibling) any changes done to spurce object does not affect target object.
    Where as Delta link will have a parent child relation ship between source object bacially its a copy of source and inherits id properties. in case if i change source object does this affect target object, we can delete, add content to delta link target object.
    let's say if i want to use standard quickpoll iView do i need to use copy or delta link similarly for other iviews, worksets, roles which one will be better.
    Regards,
    Murali

    Murali,
    Yes, your understanding is right.
    Case 1 : Copy
    A- Object
    B- Copy of A
    Both of them are independent.Any changes in A are not dependent on B and vice versa.
    Case 2 : Delta Link
    A - Object
    B - Copy of A (via Delta link)
    Any changes to A are reflected in B, as A is a parent and B a child.
    But B would be an independent entity.Any changes to B would not effect A.
    When you use either of them, depends on your need. When you are working with standard iviews or roles or workset, you can do a copy of the original, because in most cases we would not make changes to the standard roles or worksets or iviews. There by eliminating the process of making a delta copy.
    But, if you are dealing with the roles that you have created and want to make a copy of it, you can use a delta link, because, even if you want to add more iviews and worksets to that role, they would get reflected when you make a delta copy.
    Hope that helps.
    Consider rewarding points for handy posts!
    Cheers,
    Sandeep Tudumu
    Edited by: Sandeep Tudumu on May 6, 2008 2:10 AM

  • What are the main events that are used in an alvreport?

    hi
    experts can u help me for this

    Hi
    REUSE_ALV_EVENTS_GET
    Description
    This table tells ALV which events are processed by the caller by CALLBACK.
    The table of possible events per list type can be initialized using the module REUSE_ALV_EVENTS_GET.
    You can display the names of the constants in the type pools SLIS which represent the individual events using the individual test function in the function module
    REUSE_ALV_EVENT_NAMES_GET. Only events with a form routine name are processed.
    The table structure contains the fields:
    •     IT_EVENTS-NAME
    Name of the Callback event.
    Possible Callback events:
    •     Action
    USER_COMMAND USING R_UCOMM LIKE SY-UCOMM RS_SELFIELD TYPE SLIS_SELFIELD
    Process actions on the list
    As this is a frequently-used Callback event, the form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_USER_COMMAND.
    PF_STATUS_SET USING RT_EXTAB TYPE SLIS_T_EXTAB
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a template for a user-specific status.
    As this is a frequently-used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    ITEM_DATA_EXPAND USING RS_SELFIELD TYPE SLIS_SELFIELD RFLG_ALL TYPE C
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT.
    Exit for passing item entries (ITEM table) for a header record which was expanded interactively by the user.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header which is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that entries are not repeated in the item table. RS_SELFIELD is initial in this case.
    CALLER_EXIT USING RS_DATA Is called at the beginning of the function module to make special settings. It is not usually used.
    •     List processing events
    IMPORTANT: The application Callback routine must not manipulate the internal output table and/or its header record. This restriction applies to all Callbacks which are called in the list output and run under the 'List processing events'.
    TOP_OF_LIST no USING parameter. Information output at the start of the list
    END_OF_LIST no USING parameter. Information output at the end of the list
    TOP_OF_PAGE no USING parameter
    Equivalent to the list processing TOP-OF-PAGE event
    END_OF_PAGE no USING parameter. Not available for hierarchical-sequential lists.
    Information output at the end of a page. This is only called for printing.
    TOP_OF_COVERPAGE no USING parameter
    The selection information and list status are output together (if they exist) on a separate page by default. See also the documentation of the parameters:
    IS_PRINT-NO_COVERPAGE
    IS_PRINT-NO_PRINT_SELINFOS
    IS_PRINT-NO_PRINT_LISTINFOS
    IS_LAYOUT-GET_SELINFOS
    The user can format the header area of the 'cover page' himself or herself by specifying a Callback routine for this event.
    END_OF_COVERPAGE no USING parameter
    Analogously to TOP_OF_COVERPAGE the user can add other information to the information output by ALV (selection information, list status) at this event.
    FOREIGN_TOP_OF_PAGE no USING parameter
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    FOREIGN_END_OF_PAGE no USING parameter
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
    BEFORE_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
    AFTER_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    •     Internal use only
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
    R_INDEX LIKE SY-TABIX
    R_INDEX_ITEM LIKE SY-TABIX
    R_INDEX_SUM LIKE SY-TABIX
    •     IT_EVENTS-FORM
    Name of the form routine which should be called in the calling program at the event.
    Field_catalog:
    Field catalog with field descriptions
    2.7.1.     Description
    Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields). A field catalog is required for every ALV list output.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module
    See also the documentation of the function module REUSE_ALV_FIELDCATALOG_MERGE.
    The minimal field catalog is documented under 'default'. The caller can use the other optional parameters to assign output attributes to a field which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    •     The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE.
    •     all fields in this structure are to be output
    •     the structure name is passed to ALV in the parameter I_STRUCTURE_NAME.
    See also the documentation of the IMPORTING paramter I_STRUCTURE_NAME.
    Positioning
    •     row_pos (row position)
    value set: 0, 1 - 3
    Only relevant if the list output is to be multi-line (two or three lines) by default.
    A multi-line list can also be defined by the user interactively if the default list is one-line.
    The parameter specifies the relative output line of the column in a multi-line list.
    •     col_pos (column position)
    value set: 0, 1 - 60
    only relevant when the default relative column positions differ from the field catalog field sequence. The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the field catalog field sequence.
    Identification
    •     fieldname (field name)
    value set: internal output table field name (required parameter)
    Name of the internal output table field which is described by this field catalog entry
    •     tabname (internal output table)
    value set: SPACE, internal output table name
    This parameter is used in 'manual' field catalog build-up only for hierarchical-sequential lists.
    Name of the internal output table which contains the field FIELDCAT-FIELDNAME.
    Data Dictionary reference
    •     ref_fieldname (reference field name)
    value set: SPACE, Data Dictionary field name
    Name of the Data Dictionary field referred to.
    This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
    •     ref_tabname (reference table/structure field name)
    value set: SPACE, name of a Data Dictionary structure or table
    Structure or table name of the referred Data Dictionary field.
    This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Reference to fields with currency/measurement unit
    Each internal output table sum or quantity field whose decimal places are to be formatted appropriately for the unit in the list must follow the convention:
    •     the field is of data type QUAN or CURR (internal type P) (the field must really have this physical data type. Overwriting the physical data type with the parameter FIELDCAT-DATATYPE has no effect)
    •     There is a field in the internal output table which contains the associated unit.
    •     There is also an entry in the field catalog for the unit field.
    (If the unit is not to appear as a column in the list, and cannot be interactively displayed as a column, e.g. because it is always unambiguous and is therefore explicitly output by the caller in the list header, the field catalog units field entry can take the parameter FIELDCAT-TECH = 'X'.
    The association of a value field to a unit affects the output as follows:
    •     appropriate decimal places display for the unit
    •     an initialized field with a link to a non-initial unit is output as '0' for the unit (if FIELDCAT-NO_ZERO is initial). When this field is summed, this unit affects whether the units are homogeneous.
    •     an initialized field with a link to an initial unit is output as SPACE. When this field is summed, the unit SPACE does not affect the homogeneity of the units.
    •     When non-initial fields with an initial unit are summed, the unit SPACE is considered to be a unit.
    Link to currency unit
    •     cfieldname (currency unit field name)
    value set: SPACE, output table field name
    Only relevant for amount columns with associated unit.
    Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    •     ctabname (internal currency unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Link to measurement unit
    •     qfieldname (measurement unit field name)
    value set: SPACE, output table field name
    only relevant for quantity columns with unit link.
    Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME.
    The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    •     qtabname (internal measurement unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Column output options
    •     outputlen (column width)
    value set: 0 (initial), n
    For fields with a Data Dictionary link this parameter can be left initial.
    For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    initial = column width is the output length of the referred Data Dictionary field (domain).
    n = column width is n characters
    •     key (key column)
    value set: SPACE, 'X'           'X' = kex field (key field output in color)
    Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
    For exceptions see the documentation of the FIELDCAT-KEY_SEL parameter.
    •     key_sel (hideable key column)
    value set: SPACE, 'X'
    only relevant when FIELDCAT-KEY = 'X'
    Key field which can be hidden interactively.
    The key column sequence cannot be changed interactively by the user.
    The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    •     no_out (field in field list)
    value set: SPACE, 'X'          'X' = field is not displayed in the current list.
    The user can interactively choose the field for output from the field list.
    The user can display the contents of these fields at line level using the 'Detail' function.
    See also the 'Detail screen' documentation of the parameter IS_LAYOUT.
    •     tech (technical field)
    value set: SPACE, 'X'          'X' = technical field
    Field cannot be output in the list and cannot be displayed interactively.
    Field can only be used in the field catalog (not in IT_SORT, ...).
    •     emphasize (highlight columns in color)
    value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off '1'=on)
    'X' = column is colored with the default column highlight color.
    'Cxyz' = column is colored with a coded color:
    •     C: Color (coding must begin with C)
    •     x: color number
    •     y: bold
    •     z: inverse
    •     hotspot (column as hotspot)
    value set: SPACE, 'X'
    'X' = column cells are output as hotspots
    •     fix_column (fix column)
    value set: SPACE, 'X'
    Not relevant for block lists (output of several lists consecutively)
    'X' = column fixed (does not scroll horizontally)
    All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively. See also the documentation of the Layout parameter
    IS_LAYOUT-NO_KEYFIX of the IMPORTING paramter IS_LAYOUT.
    •     do_sum (sum over column)
    value set: SPACE, 'X'           'X' = a sum is to be calculated over this internal output table field.
    This function can also be called by the user interactively.
    •     no_sum (sums forbidden)
    value set: SPACE, 'X'          'X' = no sum can be calculated over this field, although the data type of the field would allow summing.
    •     input (column ready for input)
    Function not available
    Format column contents
    •     icon
    value set: SPACE, 'X'           'X' = column contents to be output as an icon.
    The caller must consider the printability of icons.
    •     symbol
    value set: SPACE, 'X'          'X' = column contents are to be output as a symbol.
    The internal output table column must be a valid symbol character.
    The caller must consider the printability of symbols.
    Symbols can usually be printed, but may not always be output correctly, depending on the printer configuration.
    •     just (justification)
    value set: SPACE, 'R', 'L', 'C'
    Only relevant for fields of data type CHAR or NUMC
    ' ' = default justification for this data type
    'R' = right-justified output
    'L' = left-justified output
    'C' = centered output
    The justification of the column header always follows the justification of the columns. Independent justification of the column neader is not possible.
    •     lzero (leading zeros)
    value set: SPACE, 'X'
    Only relevant for fields of data type NUMC
    ALV outputs NUMC fields right-justified without leading zeros by default.
    'X' = output with leading zeros
    Note: If a NUMC field is output left-justified or centered by FIELDCAT-JUST, leading zeros are output. If the output of leading zeros is suppressed by a Data Dictionary reference ALPHA conversion exit, the output is always left-justified.
    •     no_sign (no +/- sign)           Only relevant for value fields
    value set: SPACE, 'X'     'X' = value output without +/ sign
    •     no_zero (suppress zeros)           Only relevant for value fields
    value set: SPACE, 'X'          'X' = suppress zeros
    •     edit_mask (field formatting)
    value set: SPACE, template
    template = see documentation of WRITE formatting option USING EDIT MASK template
    The output conversion conv can be made by template = '== conv'.
    Texts
    The following text parameters should be specified for program fields without a Data Dictionary reference. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored. If the user changes the column width interactively, the column header text with the appropriate length is always used. The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
    The 'long field label' is also used in display variant definition, sort, etc. popups.
    •     seltext_l (long field label)
    •     seltext_m (medium field label)
    •     seltext_s (short field label)
    •     reptext_ddic (header)
    analogous to the Data element maintenance 'Header'
    The specified text is not necessarily output in the list, an optimum among all texts is sought.
    •     ddictxt (specify text)
    value set: SPACE, 'L', 'M', 'S'
    You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Parameters for program fields without Data Dictionary reference
    see also 'Text' parameters
    •     datatype (data type)
    value set: SPACE, Data Dictionary data type (CHAR, NUMC,...)
    Only relevant for fields without Data Dictionary reference
    Program field data type
    •     ddic_outputlen (external output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    •     FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    •     FIELDCAT-INTLEN = n
    see also the documentation of the parameter FIELDCAT-INTLEN
    n = external format field output length
    The column width FIELDCAT-OUTPUTLEN need not be the same as the external format output length (FIELDCAT-DDIC_OUTPUTLEN).
    •     intlen (internal output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    •     FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    •     FIELDCAT-DDIC_OUTPUTLEN = n
    see also the documentation of the parameter FIELDCAT-DDIC_OUTPUTLEN
    n = internal format field output length
    •     rollname (data element)
    value set: SPACE, Data Dictionary data element name
    F1 help can be provided for a program field without a Data Dictionary reference, or F1 help which differs from the Data Dictionary help can be provided for a field with a Data Dictionary reference, using this parameter.
    When F1 help is called for this field, the documentation of the specified data element is displayed.
    If the FIELDCAT-ROLLNAME is initial for fields with a Data Dictionary reference, the documentation of the data element of the referred Data Dictionary field is output.
    Others
    •     sp_group (field group key)
    value set: SPACE, CHAR(1)
    Field group key.
    Keys are assigned to group names in the IT_SPECIAL_GROUPS parameter (see also the documentation of the parameter IT_SPECIAL_GROUPS).
    When such an assignment is made in the field catalog and in IT_SPECIAL_GROUPS, the fields are grouped correspondingly in the display variant popup.
    •     reprep (Report/Report interface selection criterion)
    value set: SPACE, 'X'
    Prerequisites:
    •     The system contains the Report/Report interface (function group RSTI, table TRSTI)
    •     Parameter LAYOUT-REPREP = 'X'
    (see also the documentation of the parameter LAYOUT-REPREP of the IMPORTING parameter IS_LAYOUT )
    'X' = When the Report/Report interface is called, the value of this field is passed in the selected interface start record as a selection criterion.
    2.7.2.     Default
    •     The following entries are usually sufficient for internal table fields with a reference to a field defined in the Data Dictionary :
    •     fieldname
    •     ref_tabname
    Notes:
    ALV gets the remaining information from the Data Dictionary.
    If no relative column position (COL_POS) is specified, the fields are output in the list in the order in which they were added to the field catalog.
    REF_FIELDNAME need only be specifid when the name of the internal table field differs from the name of the referred Data Dictionary field.
    Information which is explicitly entered in the field catalog is not overwritten by information from the Data Dictionary.
    Priority rule:
    Entries in the field catalog have priority over differing entries in the Data Dictionary.
    •     The following entries are usually sufficient for internal table fields without a reference to the Data Dictionary (program fields):
    •     fieldname
    •     outputlen
    •     datatype
    •     seltext_s
    •     seltext_m
    •     seltext_l
    Notes:
    F1 help can be provided for program fields by assigning a data element to the parameter ROLLNAME.
    If the parameters SELTEXT_S, SELTEXT_M, SELTEXT_L, and REPTEXT_DDIC contain appropriate field labels, the program field column headers are also adjusted appropriately when the column width changes.
    <b>Reward points for useful Answers</b>
    Regards
    Anji

Maybe you are looking for

  • List bullets and IE 11 not right

    Hi, I do not understand what is going on with my unordered list in IE 11. The bullets are on the wrong side of the image. They display correctly in FF and Chrome. But IE is giving me a fit. Here is the structure: <p><img src="/portals/0/Images/patien

  • Running Dos Command using Java

    How do i run a particular Dos command using a simple java class?

  • No WWAN antena

    Dear all I bought recently new T400 notebook (product number 2765-51G). According to lenovo page, this notebook is WWAN upgradable. I have SIM card reader integrated, free PCIe slot for WWAN card, but I don't have antena cables (red and blue). I was

  • Sort Xml list

    Hello, I am trying to learn actionscript 3 for work and have a very specific project I need it for. I have been searching every available tutorial have bought a few books to read but I cannot find out how to do a few simple things. The main thing I n

  • How to do the validation for a checklist item

    I have a check item which is a date which should not allow future date. This check list item might be 1 st item or 10th or 3rd .. depending on the selection made in the previous page. How can i do validation for this item ? thanks for your help.