VALUATION NOT APPEARING IN RESULT RECORDING

Hello....
I have created an inspection plan where i have assigned all the characteristic to be inspected with quantative data.
Upon goods receipt inspection lot is generated,
while doing result recording when i enter the result for eg. if the characteristic value is 1-10, and i enter the reult as 1, the valuation has to be set automatically as accepted but its not appearing, could anyone please let me know am i missing any settings.
Suggestions will be worth appretation

Hi sarfrazbaig  ,
If you are using sampling procedure, check the "Valuation Mode". It must be "Manual Valuation" to achieve the valuation Manually.
The trx code will be QDV1/2/3 for Sampling procedure.
Regards,
Shyamal
=================================================================================
Okey if you are not using the sampling procedure then,
Set the value as "Automatic Close" / Close, Navigate and save automatically" in the IMG settings at Quality Management->Basic Settings->Maintain Settings at Plant Level, here for the relevant plant select the "Result Recording" Tab and set the mentioned vales for the field "Recording configuration"
Revert for for further inputs.
Regards,
Shyamal
Edited by: Shyamal Joshi on Aug 12, 2009 12:24 PM

Similar Messages

  • What is the setting- Pop up window 'Valuation' appears in Results Recording

    Hi,
    When i am doing Results recording in qa32, after processing all characteristics the status of all characteristics appears '5' but while saving it gives a pop-up window named 'valuation' where under 'valuate inspection point' sub screen field 'valuation' with entry 'Accept' in grey mode appears. Also a tab named 'valuation' appears on the same pop-up window with pencil symbol through with UD can be made in RR only.
    What is the setting because of which this pop up window comes while saving the results recording.
    Thanks in advance.
    Regards,
    Abhijit.

    HI,
    I am using insp. point 200 which have default valuse in valuation tab. In functional module tab no FM are attached.
    What are the setting required tobe changed in i want to use Insp. Point and do not want the Pop up window of Valuation.
    In some other cases i am using point and pop up doesn't come.
    Abhi.

  • Pricing ZCondition Types are not appearing in Condition Record Maintanence

    Hi All,
    We have a requirement in SAP CRM Opportunity Management where the pricing determination should happen. So, to facilitate the requirement we have done the following
    Downloaded the DNL_CUST_CNDALL and DNL_CUST_CND from ECC to CRM
    But the Problem is when I am trying to maintain the Condition record in T-Code "/SAPCND/GCM"  our Z-Condition types are not appearing in the list, also in Product Master Condition Tab.
    Please suggest me how to resolve this issue.
    Regards,
    karthik J

    Hi Karthik,
    As a best practice -
    1. If you are downloading the condition type and pricing procedure from ECC, then it is advisable to use ECC as a master system for all your Z condition type/condition record maintenance.
    2. Similarly if you are using Pricing procedure as of ECC, then ensure that the downloaded pricing procedure in CRM is used for pricing procedure determination.
    3. The condition record in T-Code "/SAPCND/GCM" is advisable to use if you are mainly using CRM Pricing.
    By looking at your problem statement you are using ECC pricing procedure, condition types by downloading it to CRM.
    If you have any other comments to make, please give the exact problem statement or any appropriate problem screenshot for further analysis.
    Hope this will be useful
    Thanks and Regards
    DJ

  • String limit does not appear in result list

    Hello
    I have a sequence file with a sequence call "String limit test". After running the sequence from a process model, the "Limits" container does not appear in the result list of the main sequence. I have checkec the IncludeInReport flag for the Limits container, still I don't see it.
    Basically I need this information after calling the MainSequence in the client file, in order to create a report file. How to inclide the variable in the ResultList[]?
    Madottati

    Madottati,
    All the data from Step.Result will be copied to Locals.ResultList. Limits container for the step is outside Result container and hence is not copied to the ResultList. IncludeInReport flag affects only properties that are in a result list or that TestStand copies to a result list.
    http://www.ni.com/white-paper/8289/en/ contains more details about what properties gets added to the Result List.
    You can use Additional Results feature toa add Limits container to the ResultList.
    - Shashidhar

  • Follow-Up Dropdown Lists Not Appearing in Interaction Record

    Dear SAP experts,
    I have setup Interaction Record as the leading transaction in the WebIC. In the Follow-Up area, user should be able to select a list of Transaction Type from the drop down menu eg: Sales Order, Service Request etc. I have configured the following but the dropw down menu is still not showing any items. I can however see the items only in SAP GUI, but NOT in the WebUI.
    1) Define Copying Control for transaction type eg: ZSIR (interaction record) --> ZSRV (service request)
    2) Defined the Transaction Type
    3) Defined Business Transaction Profile for ZSIR (interaction record) with Dependent Business Objects include ZSRV (service request)
    Could anyone tell me what i am missing? Do i need to perform the copy control for Item Cat as well?
    Please advice.
    Thanks

    I have not even come to that part yet. What i need now is the list of transaction types to be appeared in the Follow-Up drop down. How does partner determination cause whether the list appeared in the drop down or not. There's something really weird, when i unchecked the Settings for Activities for Business Activity Copy Control, one of the item does appeared in the drop down.

  • Results are not appearing in report

    Hi All,
    When user ran the report, it gives below error.
    A general error has occured[nQSError:1207]Unexpected socket read timeout: connection terminated by network, e.g. by the firewall.
    But when ran the query in the backend it fetching the results and in criteria it contains SET OPERATOR with UNION,but not appearing the results in report.
    Regards,
    Niranjan

    Hi, Thanks for your response...
    When i ran the report with diffrent/default combination then i am getting the results.
    In my criteria SET operator is used for combining of similar request and we have diffrent filter conditions and dashboard prompts also.
    Connection from back end is fine,because iam able to get other report results also.
    Regards,
    Akkapeddi

  • Padlock sign is not appearing before Record in Record Center Template

    Hi All,
    I am facing quite a strange problem.
    In SharePoint 2010 Record Center Template Site whenever i declare a document as a Record OR Hold the document "padlock" sign is not appearing before the Record.
    Although in case of Team Suite Template whenever declare a Record using In place Record management OR Hold the document "padlock" sign appears.
    Is it OOB beahvior OR am i missing some settings???
    Any comments on this would be appreciated.

    Hi,
    This is true in my virtual machine as well. I am able to edit data and meta data in documents that are on hold. This is because holds add meta data to documents and
    prevent document deletion but do not necessarily prevent editing.
    If you would like to prevent users for editing a document you will need to edit user permissions on that document itself; which can be done in the document drop down
    under 'Manage Permissions' in the Records Center library.
    Regards, Savoeurn Va Microsoft Online Community Support

  • Text boxes not appearing - CAPTIVATE1.1

    I have a number of delegates using Cap1.1 - on some machines
    when recording screens, the automatic text boxes are not appearing
    when the recording has finished. (the "text box" option is checked
    on all PCs in the custom options settings)
    I`m sure i`ve heard this could be something to do with Flash
    players - I checked one of the machines that is facing the issue
    and its using Flash 9.
    any help would be great
    cheers

    Sorry, I only keep the current version and one version back
    due to storage limitations. I would note that there are few things
    more difficult than to suggest a correction for an "intermittent"
    problem, but I'd have to say an intermittent problem
    on a version that was replaced years ago would definitely
    qualify as the most difficult of all.
    That said, maybe we can offer some help if we knew what the
    problem was. You don't really say, except that some text-captions
    on some machines are not appearing. That is not really helpful in
    troubleshooting.
    What is being recorded - exactly?
    Where is it being recorded from - Internet, local drive,
    etc.?
    What are the delegates (what's a delegate?) doing at the time
    they expect, but are not getting, automatically-generated
    text-captions?
    I am relatively certain that the problem (if I understand
    that part), has nothing at all to do with the Flash Player version
    installed, but beyond that, I'm sorry that all I can offer is
    questions instead of answers.
    Welcome to the User-to-User forums, hardyandy. Hopefully you
    can give us enough additional information that we can take a stab
    at helping out.
    .

  • Specifications in Result Recording

    Hi QM Gurus,
    Here I encountered an interesting problem, Lower and Upper specification limit have been maintained in inspection plan.
    However, when make result recording the Lower and Upper specification limit are not transported into result recording screen.
    Pls help.
    Cheers,
    Sun

    Hi Sun
    I think Inspection Plan Operation Detail setting is disturbed.
    Go to Change Task List (QP02) ->  Operation -> Select Operation and open Operation Details (F6) -> Scroll down  find for Recording View in Quality Management General tab.
    By default Recording View is set to "Single Value & Summurized Result". If it is not then set.
    Hope this will resolve your problem
    Atul

  • No results Recording without UD

    Friends,
    My client requirement is that, there should not be any results recording without any usage decision in case of inspection activities of procured raw material ?
    Is there any setting available?  P. guide

    Hi,
    Refer this wonderful article. [http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/20fbc091-ea3a-2b10-f0a3-877ffbf36436?quicklink=index&overridelayout=true]
    Regards,
    Anand

  • Results recording tab not appearing in QA32

    hi,
    can anyone tell me why results tab not appearing in QA32 , is there any authorisation missing?

    Just check which roles are added to that used id
    selec 1 role that is relevent to inspection (result recording) and add QE01 t_code in that role.
    take help from ur basis guy for this.

  • Result recorded values not appearing in printing the Inspection lot

    Hi all ,
    Using QC21 i am printing the Inspection lot  but the Result recorded values  are not appearing in printing the Inspection lot .
    while creating the certifacte  profile i had maintained the MIC for which i had saved as Summary for recording . if i change this to Orginal value it says that this doesnt exist in the Inspection plan .
    can somebody help me on this .
    thanks ,
    ksr

    Hi
    1.Make sure that you are using same MIC in Task list & certificate.
    2.make sure that you have done RR & taken UD.
    3.make sure that MIC is reference MIC.
    4.Make sure that profile is attached to material
    Regards
    Sujit

  • "Result" row not appearing for the Structure record in Bex Designer.

    Hi
    In BI BEx Designer,
    under Rows-> click any Characteristic-> Display Tab-> Result Rows: "Always Display" Option controls Last Row named "Result" (yellow colored) after the actual data reports ends.
    But i am not finding this thing for the structure.
    Actually my this report is based on 'Structure-> 2 selections' under Rows; once i run this query i get data without yellow colored 'Result" row at the end of report. I wanted to maintain the symmetry with other reports.
    Could u pls let me know how to get Query last "Result" record if i use only structure under the rows.
    Thanks...

    I limit the selection to display in one page, i see the overrall result but i've a result to show up after a Characteristic (result row option 'Display with more than one single value'), it works fine in BEx but not in web.
    for the other query, yes i do KF in the report.
    thanks

  • Result recording not saved

    Hi,
       PP QM Gurus,
       I m doing result recording for a insoection lot. Once i have saved valuated, locked and saved the results for same results only. When for other results i go through QE12 system is showing me all blanks results. The results which i have recorded before are also appearing blank. Why this is happning. Please help me out.
    Thanks and Regards,
    Harriesh.

    Hi,
    Normally if the result is recorded and the processing status is 5, it should not happen. Just for confirmation, Could you please tell me whether you are checking for the same inspection point and the Characteristic filter is "Closed characteristics"?
    Regards,
    Srinivas.D

  • BAPI_INSPOPER_RECORDRESULTS:result does not appear in inspection lot...

    Hi,
    I am using BAPI_INSPOPER_RECORDRESULTS to record inspection lot result at characteristic level.
    When I use this BAPI, it does not give me an error.
    But the values against each characteristic does not appear  in the result field of that characteristic.These are not getting updated. system status shows INSP RREC.
    I am passing the result value as  "mean-value" field in bapi charresult table..
    what is the solution for this?
    I am trying BDC for the same purpose in tcode QE51N. but in between there is error msg promp..so BDC is not working after that promp as it is asking for user entry for the mandetory field "Engineer's name"..
    Kindly provide the solution..

    Hi,
    maybe QE11 is an option for recording results vai BIM.
    Cheers,
    S>

Maybe you are looking for