Varient for module pool screen

can we create varient for module pool screen.

<b>namaste anil anna.</b>
how is pune .
how is erwada joil.
salman khan vunnada leda
Try out on the filled screen:
System - User defaults - Keep data
If you re-run it:
System - User defaults - Restore data
or try this link
http://help.sap.com/saphelp_nw04/helpdata/en/7d/f63a0a015111d396480000e82de14a/content.htm
regards
nagaraju madipadiga
hcl technologies
09958011191

Similar Messages

  • Variants for module pool screena

    Hi,
    I tried creating a variant for module pool screen by using the FM : RS_CREATE_VARIANT.
    For this i created a dummy report which has the same parameters as the fields in the screen.
    CALL FUNCTION 'RS_VARIANT_CONTENTS'
            EXPORTING
              report                      = gc_dummy_rep
              variant                     = 'variant5'
            MOVE_OR_WRITE               = 'W'
            NO_IMPORT                   = ' '
            EXECUTE_DIRECT              = ' '
          IMPORTING
            SP                          =
            tables
            L_PARAMS                    =
            L_PARAMS_NONV               =
            L_SELOP                     =
            L_SELOP_NONV                =
              valutab                     = lt_params
            OBJECTS                     =
            FREE_SELECTIONS_DESC        =
            FREE_SELECTIONS_VALUE       =
          EXCEPTIONS
            VARIANT_NON_EXISTENT        = 1
            VARIANT_OBSOLETE            = 2
            OTHERS                      = 3
          IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
    but when i try to retrieve the values stored in the variant using FM : RS_VARIANT_CONTENTS.
    CALL FUNCTION 'RS_VARIANT_CONTENTS'
            EXPORTING
              report                      = gc_dummy_rep
              variant                     = 'variant5'
            MOVE_OR_WRITE               = 'W'
            NO_IMPORT                   = ' '
            EXECUTE_DIRECT              = ' '
          IMPORTING
            SP                          =
            tables
            L_PARAMS                    =
            L_PARAMS_NONV               =
            L_SELOP                     =
            L_SELOP_NONV                =
              valutab                     = lt_params
            OBJECTS                     =
            FREE_SELECTIONS_DESC        =
            FREE_SELECTIONS_VALUE       =
          EXCEPTIONS
            VARIANT_NON_EXISTENT        = 1
            VARIANT_OBSOLETE            = 2
            OTHERS                      = 3
          IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
    I get an error message : variant5 not found.
    is there anything that i miss here?
    or is the way i use to create variant for module pool screen not right?
    Regards,
    Kamini

    Hi,
    To avail save variant option in module pool screen,
    1. You need to create a data base table similar to INDX table with the fields RELID, VARI_NAME
    PROG_NAME
    UNAME
    SRTF2, MEMORYID, CLUSTR,  CLUSID. And the remaining fields can be anything.
    2. Enable the Save button in the Function keys part of GUI Status. And Add a push button for Get variant.
    3. When Save button clicked call a screen with a single field for variant (let us say g_var). After g_var entered, in the PAI of the initial screen export all the screen values to the created database index using the statement .
                         EXPORT: g_characteristics_tab TO DATABASE zav0257(ch) ID g_var,
                                       s_auart TO DATABASE zav0257(au) ID g_var.
                         So that the values will be exported to database.
                         Then update the fields(VARI_NAME,PROG_NAME,UNAME) of  the database table using modify from work area. 
                         So that you will have the history of variance existence.
    4. Next time , when the user clicks on Get Variant option, call another screen to enter the variant name. Then import the values for that variant from the memory id in the database table.
    It worked for me.

  • How can one save variants for module pool screens.

    hai all,
         i have done a module pool screen for taking information from user..later i leave to list processor and give a report to the user.
      i am testing the program with many input parameters.i don't want to enter the values each time i execute the program.can i not save a variant like i save for normal abap editor programs?
    any other solution ?

    Hii..
    Variants can be created in Selection Screen only...
    For ur Scenario:
    To leave to the list use the Statements
    <b>LEAVE TO LIST-PROCESSING And return .</b>
    then the Data will be automatically retained.
    <b>Reward if Helpful</b>

  • Icon display in Module pool screen not visible to some users

    Hi,
    I have added an icon in one of the module pool screen with dynamic quick info.  The page is rendered fine and the info is also displayed well for most users except some.  I can't figure out why the icon is not being displayed for some users.
    Do someone has any solution for this?
    Thanks,
    Sumith

    As I recall, the icons are actually stored in a file on each PC so some users may have a corrupted or out-of-date file with the icons.  You can look for posting on "how to add an icon" to see a discussion on this topic.
    I found some useful info at:
    Create and Add Icons to table ICON?
    Message was edited by: Charles Folwell

  • How to get the Grand Total in Module pool Screen

    Hi Frds.
         How to get the Grand Total in Module pool Screen
    Example i have 10 different materials
    for each matarial has different moving . But in my case matarials is doesnt matter here
    10 material Moving Average price to do Frand total and display in one column...
    Please Help me out Frds.
    Regards,
    Kabil

    Hi
    You need to calculate the total in a module of PAI (or PBO) event:
    PROCESS PAI.
       LOOP.....
       ENDLOOP.
      MODULE CALCULATE_TOTAL.
      MODULE CALCULATE_TOTAL.
        GRAND_TOTAL = 0.
         LOOP AT ITAB,
            GRAND_TOTAL = GRAND_TOTAL + ITAB-PWB.
        ENDLOOP.
    ENDMODULE.
    In this way the grand total will be calculated as soon as the user presses enter or another command.
    You can't insert the calculation in the loop of table control, because this loop runs the visible lines only, so it's better to calculate the total out of those loop,

  • How to retain leading zeros in module pool screen

    Hi experts,
    I have a ztable field of type NUMC4 being displayed on a module pool screen, the value in the field is '0001', but on the screen it displays value as '1' (without leading zeros), When I save the record, Even in the databse it stores as '1'.
    But I have checked in debugging the field always contains '0001' in the program execution and I have also used 'CONVERSION_EXIT_ALPHA_INPUT' in the PBO but no use.
    Pls suggest.
    Thanks,
    Deepak

    Check the screen attributes for the field. There is an option to show leading zeroes.
    edit.
    And how did you see it was stored a 1 and not 0001? Using SE16N? Mind you: with SE16N conversion-exits are executed automatically thus showing 0001 as 1.
    To make sure: double click on the record in SE16N and look if it's still 1 and not 0001.

  • How to give ** bydefault in password in module pool screen .

    Hi experts
    how to give  *******  by default in password in module pool screen .
    Thanks

    Hi ,
        Double click on the field u will get a pop up window
        i.e. attribute window for that field.
        in that window you have a tab called Program at the bottom.
       in program tab you have many checkboxes.
      check the check box with name *Entry.
      and activate.
    what ever you enter now will be in password formate
    Regards
    Ajay

  • Call module pool screen from ABAP Webdynpro

    Hi All
    I designed one screen in normal classical dynpro in SE80 for module pool program. I want to call that screen layout design in webdynpro view layout.
    So please help me how can i call that module pool screen from my ABAP webdynpro 

    Hi
    Thank you for your great replay. But Mr Ramakrishnappa and Mr Katrice as your reference i go through that but when i insert the program name and screen number program is end with a run time error saying
    dynamic type conflict when assigning reference.
    Please refer the below snap shot

  • Displaying MIR4 attachment list TIF image in module pool screen

    Hi All,
    I have a screen with a custom container and I tried to call a TIF image from MIR4 which is in attachment list(which is stored in archived link).
    I need a function module to display this image in my Module pool screen using the container.
    I tried using below code
    * Create controls
         CREATE OBJECT container_1
           EXPORTING
             container_name = 'CONTAINER'.
    *    create object container_2
    *      exporting container_name = 'PICTURE_CONTROL_2'.
         CREATE OBJECT PICTURE_CONTROL_1
           EXPORTING
             parent = container_1.
    *    CREATE OBJECT PICTURE_CONTROL_2 exporting parent = container_2.
    CALL METHOD PICTURE_CONTROL_1->LOAD_PICTURE_FROM_URL
           EXPORTING
    *    URL    = 'SAPR3://984BE16932C81EE3B2AA1E3B0D12C6FF'
    *      URL    = 'file://E:\Personal\New_Passport4.jpg'
    *       URL    = 'SAPR3://984BE16932C81EE3B2BDF8E44B035648.TIF'
    *URL    = 'SAPR3://SAPR3CMS/get/100/Z1/984BE16932C81EE3B2BDF8E44B035648//.TIF'.
         URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000'
         IMPORTING
              RESULT = lv_result.
    CALL METHOD PICTURE_CONTROL_1->set_display_mode
         EXPORTING
           display_mode = PICTURE_CONTROL_1->display_mode_fit_center.
    But I am able to display this URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000' and not able to display my archive link image which is in TIF.
    note: Display image of Arc.link Doc.type ZBUSI_TIF (doc.class TIF)
    Please help me on this.
    Thanks
    Geetha Charan

    Hi sai,
    Please refer th procedure.
    For the select-options you might have defined a selection screen.
    Next you can fetch the entire data that you wanted to display in a module pool into an internal table.
    you can call the screen you defined for o/p upon the selection.
    Then, You define a screen XXXX  and a table control in the scree, and in the PAI module of the screen
    you write a chain end chain processing in which you can display the contents of your internal table.
    OR
    if you want the selection also to be in the module pool,  then for displaying the O/P you can definr a sub-screen of the initial screen and you can call that sub-screen on selcting, which can be done with a function code.
    Hope this helps

  • Problem in creating a Select-option im a module pool screen

    I've been searching how to do a select option in a module pool screen, I've found this neat tutorial http://sample-code-abap.blogspot.com/2008/06/select-option-in-module-pool-screen.html
    but I'm having trouble to replicate it...
    I've created this conde in my TOP include
    SELECTION-SCREEN BEGIN OF SCREEN 201 AS SUBSCREEN.
       SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME.
        SELECT-OPTIONS: s_matnr FOR mara-matnr.
      SELECTION-SCREEN END OF BLOCK b2.
    SELECTION-SCREEN END OF SCREEN 201.
    and this is my screen flow code
    PROCESS BEFORE OUTPUT.
      MODULE status_0100.
      MODULE pbo_200.
    PROCESS AFTER INPUT.
      MODULE pai.
      MODULE user_command_0200.
    in the screen 200 I have a subscreen area named subs
    but when I do this:
    MODULE pbo_200 OUTPUT.
      CALL subscreen subs including sy-repid '0201'.
    ENDMODULE.                 " pbo_200  OUTPUT
    it doesn't "compile"
    it gives me this error:
    ""." or "ID ... FIELD ..." expected after "SUBSCREEN"."
    what am I missing? it seems its not recognising the "CALL SUBSCREEN" command...

    you can't use CALL SUBSCREEN... in any ABAP section. It is reserved to dynpro flow logic. Just add it after PROCESS BEFORE OUTPUT (and also after PROCESS AFTER INPUT).

  • Display Continuous Fluctuations in Input Data in Module Pool Screen

    Dear All,
    We are working on a Weighbridge Interface scenario, where the weighbridge is sending data to a digitizer, which is connected to the COM port of a PC. The objective is to read the data from the digitizer, and display in a Module pool screen. However, there is one more requirement: the weight may fluctuate until it stabilizes, and the fluctuations have to be displayed on screen. For example, the tare weight of a vehicle may be 12.4 TON, but when the vehicle is standing on the weighbridge, the weight may vary from 10.4 to 12.4 TON. The idea is to capture the stable weight, so that any discrepancies can be avoided. In the current IT system implementation, the fluctuations in the weight are displayed. But using ABAP, can these fluctuations be captured? For example, we may design a screen containing a field for capturing the weight, and the weight displayed there automatically refreshes as soon as there is a change in the digitizer reading. Is this possible to achieve? If so, how?
    Awaiting answers.
    Thanks and Regards,
    Sid

    Hi Sid,
    just a suggestion for the refreshing of an ABAP screen: you can use class CL_GUI_TIMER, but it only handles whole seconds, i.e. 1 second, 2 seconds and so on, but not 0.5 seconds...
    An example of an ABAP listing could be the following:
    *& Report  ZZAVV001
    REPORT  zzavv001 NO STANDARD PAGE HEADING.
    CONSTANTS: c_yes(1) TYPE c VALUE 'X'.
    DATA: BEGIN OF t_bseg OCCURS 0.
            INCLUDE STRUCTURE bseg.
    DATA: END OF t_bseg.
    data: d_num_bkpf type i,
          d_num_bseg type i.
    PARAMETERS: interval TYPE i DEFAULT 5.  "meaning 5 seconds
    *       CLASS lcl_receiver DEFINITION
    CLASS lcl_receiver DEFINITION.
      PUBLIC SECTION.
        METHODS:
          handle_finished FOR EVENT finished OF cl_gui_timer.
    ENDCLASS.                    "lcl_receiver DEFINITION
    * Global data
    DATA:
      test       TYPE i,
      receiver   TYPE REF TO lcl_receiver,
      timer      TYPE REF TO cl_gui_timer.
    START-OF-SELECTION.
      CREATE OBJECT timer.
      CREATE OBJECT receiver.
      SET HANDLER receiver->handle_finished FOR timer.
      timer->interval = interval.
      CALL METHOD timer->run.
      PERFORM load_data.   "or whatever you have to do to read the weight
      PERFORM show_list.   "or whatever you have to do to print the weight you've read
    *       CLASS lcl_receiver IMPLEMENTATION
    CLASS lcl_receiver IMPLEMENTATION.
      METHOD handle_finished.
        PERFORM carga_datos.
        PERFORM muestra_listado.
        CALL METHOD timer->run.
      ENDMETHOD.                    "handle_finished
    ENDCLASS.                    "lcl_receiver IMPLEMENTATION
    *&      Form  load_data
    *       text
    FORM load_data.
      clear: d_num_bkpf,
             d_num_bseg.
      select single count( * )
        into d_num_bkpf
        from bkpf.
      select single count( * )
        into d_num_bseg
        from bseg.
    ENDFORM.                    "load_data
    *&      Form  show_list
    *       text
    FORM show_list.
      get time.
      skip to line 1.
      position 1.
      write: / 'Date / Time:', sy-datum, sy-uzeit.
      write: / 'Number of BKPF records:', d_num_bkpf.
      write: / 'Number of BSEG records:', d_num_bseg.
    ENDFORM.                    " show_list
    Okay, it's just a tiny code snippet, but I hope it may help you by designing auto-refreshing screens.
    Kind regards,
    Alvaro

  • Expand/collapse button functionality on module pool screen

    Hi ,
    I want to design a module pool screen with a expand/collapse button on it.
    The desired functionality associated with this button would be something similiar to that available in ME21N screen. When the expand button is clicked it should open up a section of screen that allows the user to enter some parameter. Based on this parameter some selections from DB can be perfomed and then displayed below it.
    Any pointers on how to achieve this? Any kind of help would be appreciated.
    Regards-
    Harmeet Singh.

    example for three pushbutton with expand collapse .
    First of all define your push button as output field with icon tick in the pushbutton characteristick,
    then define this pushbutton in top_include
    include <icon>.
    data : push_a1 like icons-l4,
             push_a2 like icons-l4,
             push_a3 like icons-l4.
    data : a1 ,
             a2,
             a3.
    in pai of the screen
    suppose i had assign function code a1 ,a2 , a3 for repective pushbutton
    module user_command_9002 input.
      okcd = ok_code.
      clear ok_code.
      case okcd.
        when 'A1'.
          if a1 is initial.
            a1 = 'X'.
          else.
            clear a1.
          endif.
        when 'A2'.
          if a2 is initial.
            a2 = 'X'.
          else.
            clear a2.
          endif.
        when 'A3'.
          if a3 is initial.
            a3 = 'X'.
          else.
            clear a3.
          endif.
      endcase.
    endmodule.                 " USER_COMMAND_9002  INPUT
    define three seprate screen -group for three pushbutton say a1 a2 a3
    during pbo you can directly assign name of icon .
    if a1 is initial.
        push_a1 = icon_collapse.
      else.
        push_a1 = icon_expand.
      endif.
      if a2 is initial.
        push_a2 = icon_collapse.
      else.
        push_a2 = icon_expand.
      endif.
      if a3 is initial.
        push_a3 = icon_collapse.
      else.
        push_a3 = icon_expand.
      endif.
    loop at screen.
        if screen-group1 = 'A1'.
          if a1 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        elseif screen-group1 = 'A2'.
          if a2 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        elseif screen-group1 = 'A3'.
          if a3 = 'X'.
            screen-invisible = 1.
            screen-input = 0.
            modify screen.
          else.
            screen-active = 1.
            screen-invisible = 0.
            screen-input = 1.
          endif.
        endif.
      endloop.
    regards,
    Alpesh
    Edited by: Alpesh on May 28, 2009 10:28 AM

  • Module-pool screen field value under POV event

    Hi All,
    I have one issue...please suggest me solution for this.
    In module-pool program i have one screen(1000) which has one field(hrname_1000).
    Under this event:
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    under this module hename_1000 i have used F4IF_INT_TABLE_VALUE_REQUEST to put a search help for field hrname_1000.
    after that i am trying to retrive HR related stuff's based on the field on module-pool i.e i am using hrname_1000 in the where condition.
    but problem is that im not getting value for hrname_1000 which im giving in the module-pool screen.
    thats y my select query is not working.
    Where as im getting values for the hrname_1000 under PBO & PAI.
    It will look like below.
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    (under the above module)
      SELECT DISTINCT ename plans FROM pa0001 INTO CORRESPONDING FIELDS OF TABLE itab WHERE stell = '50001026'.
          LOOP AT itab INTO wa WHERE ename = hrname_1000.
          ENDLOOP.
    Please suggest
    Thanks & regards
    Ansumesh

    In some of the cases the screen field is present in the screen but not holding the value in the required structure or field.
    so here u need to check the option of reading the screen field values explictly..
    //once u hit an enter and do the f4 i think the value will be there ...but if u dont hit enter and do an F4 the value cannot hold and i think u r in this case ..
      1.Fill the screen field name in the structure dynpread.
    DATA: BEGIN OF DYNP_VALUES OCCURS 10.
            INCLUDE STRUCTURE DYNPREAD.
    DATA: END   OF DYNP_VALUES.
    DYNP_VALUES-FIELDNAME = 'HRNAME_1000'.
      APPEND DYNP_VALUES.
    * read screen values
      CALL FUNCTION 'DYNP_VALUES_READ'
        EXPORTING
          DYNAME     = HELP_REPID  "call the repid of ur prog
          DYNUMB     = HELP_DYNNR "pass the screen number
        TABLES
          DYNPFIELDS = DYNP_VALUES
        EXCEPTIONS
          OTHERS     = 1.
    now dynp_values hold the field name and field value of the screen .
    now
    SORT DYNP_VALUES BY FIELDNAME.
        READ TABLE DYNP_VALUES WITH KEY 'HRNAME_1000' BINARY SEARCH.
        IF SY-SUBRC EQ 0.
          HELP_XXXX = DYNP_VALUES-FIELDVALUE. "store the value into a variable
          TRANSLATE HELP_XXXX TO UPPER CASE.               
        ENDIF.
    Now check the code with the value if its getting populated which once there will make ur select work ..
    Vijay..

  • Getting select options in module pool screen

    hi experts,
    can any one suggest me how to provide select options in module pool screen.
    thank you,
    regards
    vijay

    Hi,
    Take two fields on screen first for low value and other for high value (say vbeln_low and vbeln_high) also design a button next to the high textbox for select-option button used to display popup.
    Using these two input fields append a range (say r_vbeln for vbap-vbeln) for the field to be used (either in query or anywhere).
    ranges : r_vbeln for vbap-vbeln.
      IF NOT vbeln_high IS INITIAL.
        IF NOT vbeln_low LE vbeln_high.
          MESSAGE e899 WITH text-007. "high value is smaller than low value
        ENDIF.
      ENDIF.
      r_vbeln-sign = 'I'.
      r_vbeln-low = vbeln_low.
      IF vbeln_high IS INITIAL.
        r_vbeln-option = 'EQ'. "if user takes only a singlr value
      ELSE.
        r_vbeln-option = 'BT'. "if user takes both low & high value
        r_vbeln-high = vbeln_high.
      ENDIF.
      APPEND r_vbeln. "append range
      CLEAR r_vbeln.
    On the button click call this FM to call a popup for select-options.
    DATA : tab TYPE rstabfield.
    tab-tablename = 'VBAP'.
    tab-fieldname = 'VBELN'.
      CALL FUNCTION 'COMPLEX_SELECTIONS_DIALOG'
       EXPORTING
         title                   = text-002
         text                    = ' '
         signed                  = 'X'
    *         lower_case              = ' '
    *         no_interval_check       = ' '
    *         just_display            = ' '
    *         just_incl               = ' '
    *         excluded_options        =
    *         description             =
    *         help_field              =
    *         search_help             =
         tab_and_field           = tab
        TABLES
          range                   = r_vbeln
       EXCEPTIONS
         no_range_tab            = 1
         cancelled               = 2
         internal_error          = 3
         invalid_fieldname       = 4
         OTHERS                  = 5.
      IF sy-subrc EQ 2.
        MESSAGE s899 WITH text-003. "no value selected
      ELSEIF sy-subrc <> 0 AND sy-subrc <> 2.
        MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
      ENDIF.
    This whole code will append your range r_vbeln to be used in program.
    Hope this solves your problem.
    Thanks & Regards,
    Tarun Gambhir

  • Selct Options in Module Pool screen.......

    Hi Gurus,
    We know the way to get the Select options on the Module -Pool screen as follows....
    Create 2 separate fields in your screen layout - one for the low value and one for the high value. Insert an icon beside the high value which will call the multiple selections popup screen on user command. Use function module COMPLEX_SELECTIONS_DIALOG to achieve this.
    I have tried the same as a test run for the FM. .but not returning meaningfull range......
    Can any 1 clerify where the code containing the FM has to be included in the Screen flow (inside PAI, PBO or else) to get the range which can further be used inside the code for database selections or else..... .
    Secondly, how is the inserted icon populated and  used while coding........????
    Thanks And Regards,
    Abhi........

    Hi
    Please find the below code u will get select options
    dont create any screen fitst jus type of prog is 'M' and create a tcode with 100 screen
    than execute u will get select options
    TABLES:VBAP.
    SELECTION-SCREEN BEGIN OF SCREEN 100 .
    SELECTION-SCREEN BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001.
    SELECT-OPTIONS S_VBELN FOR VBAP-VBELN.
    PARAMETER P_WERKS LIKE VBAP-WERKS.
    SELECT-OPTIONS S_ERDAT FOR VBAP-ERDAT.
    SELECTION-SCREEN END OF BLOCK B1.
    SELECTION-SCREEN END OF SCREEN 100.
    Regards
    Surendra

Maybe you are looking for

  • How do I use my Initial Airtime on an Iphone 4?

    I recently recieved an Iphone 4 for Christmas.  When the phone was purchased from the Verizon website a $45 initial airtime was bought with it.  The phone is not allowing me to use this airtime and is trying to make me pay for more airtime.  How can

  • Org Unit Manager View

    Hi Experts, We have the following problem concerning the Org Unit Manager View : we cannot see the name of the manager who is responsible for an Org Unit. However we can see his photo stored in the R/3 and when pointing the cursor on the 'No Manager'

  • Adobe DPS: Direct Entitlement API Version 2

    Hi guys, I have some questions about Direct Entitlement API Version 2 (http://download.macromedia.com/pub/developer/dps/entitlement/direct-entitlement-api.pdf). Based on the API, SignInWithCredentials and entitlements request body will contain a XML

  • I have an apple id but when i want regester with icloud on my iphone  I get the message "THE MAXIMUM NUMBER OF FREE ACCOUNTS HAVE BEEN ACTIVATED ON THIS IPHONE."

    I have an apple id but when i want regester with icloud on my iphone  I get the message "THE MAXIMUM NUMBER OF FREE ACCOUNTS HAVE BEEN ACTIVATED ON THIS IPHONE." On the web of icloud when i try to sign in with apple ID i get the Message "THIS APPLE I

  • PSE10 won't start

    I just installed Photoshop Elements 10 for the 2nd time.  When I first turn on the computer, or first sign into my user name the organizer appears to start fine.  After closing the program, it will not start again until I have logged out and logged b