Version Change in User Exit , Customer Exit, Screen Exit
Hi All,
If Version change then whether the user exit, customer exit & screen exit will remain same? or what needs to be done for that?.
Regards,
Abhijit
Hi,
as per my knowledge there is no effect in the user exit ,in generally when version change the screens are chenges for particular transaction not the user exit .
Regards,
Madhu
Similar Messages
-
To find user exit and a screen exit for VD03
hi ,
can u please find if there is a user exit and a screen exit to add for adding a Z-field on for the customer master on the shipping tab. i.e VD03 transaction.
actually i have found the user-exit i.e exit_SAPMF02d_001.
but this exit is not triggering when i put a breakpoint.
so can u please tell me the solution for this.
regards,
soham pHi,
try these...
Enhancement/ Business Add-in Description
Enhancement
SAPMF02D User exits: Customer master data
Business Add-in
CUSTOMER_ADDRSCR_CHG Change Address Screen in the Master Data Maintenance
CUSTOMER_ADD_DATA Additional Data at Customers
CUSTOMER_ADD_DATA_BI Additional Data at Customers (Batch Input and ALE)
CUSTOMER_ADD_DATA_CS Additional Data at Customers (Subscreen Container 4000)
No.of Exits: 1
No.of BADis: 4
Arunima -
P.O change if i change only screen exit field the data is not saving
Hi ,
In the purchase order header custom tab i am added a screen exit field .In the purchase order creation mode the screen exit field is saving.But in the change mode if i am changing only the screen exit field then it is showing as 'no data to save' and not saving .But at the same time if i am changing some standard field with the screen exit field then both the field is saving.
I have to activate any field to save the screen exit field.Please let me know any exit to be activated for saving the data.
With Regards,
AmbroseHi
Pls keep a break-point in the PAI of Screen exit and check, whether it stops in change mode
Regards
Madhan D -
Screen Exit .. Change tab name.. IMP.
Hi,
Can any one please let me know, from where to change the tab name in a screen exit.
When I activate the exit, a new tab is added in the tabstrip control, I have designed the layout, but from where I can put the desired name in the tab.
Thank you in advance.
Best Regards,
SandipanHi Sandipan,
I'm trying to do the same. Did you find a solution to this?
Cheers,
Amy -
hi everyone,
can you send me some examples on menu exits and screen exits.
thank you.
preethamHi Preetham,
In older versions MENU Exits approached through Transaction CMOD by creating
PROJECTS and activating the project and assigning Program to that
Transaction Codes. For MENU Exits, Transaction Codes will be starting with
"+" sign and with default text "NODE TEXT NOT FOUND" for which you can
assign your Report or Dialog Program etc., (for Eg:- +DW4 MENU Exits
Transaction available in TOOLS --> ABAP Workbench --> Utilities --> <Node
Text Not found>).
Procedure for Creating MENU Exits.
1) To get into Area Menu Maintenance Screen Type SE43 T.Code in Command
Line.
2) In Area Menu Paramenter type 'S000' (S triple Zero)
3) Then Press Change Icon in Application Tool Bar. Then It may ask for
Access Key [or] it may display "Specify Processing mode" window. If it ask
for the Access Key Check for the availability of OSS Note and apply to open
Standard SAP Menu to include MENU Exits. Otherwise, if it display "Specify
Processing mode" window with Three Push Button. In which select "Change" and
proceed further.
4) Then it will display "Information" window with the following information
"Caution : The Original Language of the structure is German (editing lang. :
English) ". Then press "Enter Key to proceed further.
5) Then you will get into "Edit Area Menu S000".
6) for eg:- Expand Tools Menu.
7) Then Press ABAP Workbench <Icon>.
8) Then you will get into ABAP Workbench Menu Tree.
9) Then Expand Utilities Menu.
10) In the last line you will find one MENU EXIT Provision to include your
own menu. "Node Text Not Found" This text can be change by double Clicking
that. There you can find the T.Code. Here for Eg:- "+DW4".
11) for eg: - Here change the Text to "Sample Menu Exit" and then note down
the T.Code "+DW4".
12) Then Save with Change Request Number and come out of Transaction SE43.
13) Then Goto Transaction SE93.
14) Then type T.Code "+DW4" and press Create.
15) Then proceed further to create transaction called "+DW4".
I hope this could help you in Creating Menu Exit...
Creating menu exits
http://help.sap.com/saphelp_nw04/helpdata/en/c8/19762743b111d1896f0000e8322d00/content.htm
http://help.sap.com/saphelp_nw2004s/helpdata/en/83/7a18cbde6e11d195460000e82de14a/frameset.htm
For screen exits.
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen
check the foll link,
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
Menu exits allow you to add your own functions to the pulldown menus in standard R/3 transactions. To take advantage of a menu exit, you first need to create a project as described in the section Creating an add-on project. Then, you must include the SAP enhancement package that contains the menu exit you want to use in your project. From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
The system lists all customer exits contained in the enhancements included in your project.
Place the cursor on the menu exit you want to add your own function to.
Choose Edit component.
The system displays technical information about the menu entry. It also displays two input fields where you can specify a language and the text you want your menu item to have.
Enter the name of your menu function (such as Special order method) in the field New text.
Choose Save text.
Your special menu function will not appear in the pulldown menu of the corresponding standard transaction until you activate your enhancement project.
Specifying a menu text and activating your project are not the only steps you need to take to make your own menu item work. After you carry out these steps, your menu item will appear, but it will not call a corresponding function. To attach your menu entry to its corresponding function, you need to create a function module for the function module exit associated with your menu text. This function module exit is part of the same SAP enhancement that contains the menu exit you used. Creating Customer-Specific Function Modules tells you more about how to use function module exits.
also refer
MEnu Exit
http://www.sap-img.com/abap/what-is-user-exits.htm
Creating menu exits
http://help.sap.com/saphelp_nw04/helpdata/en/c8/19762743b111d1896f0000e8322d00/content.htm
http://help.sap.com/saphelp_nw2004s/helpdata/en/83/7a18cbde6e11d195460000e82de14a/frameset.htm
For screen exits.
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
chech these links for user exists its usefull
http://www.allsaplinks.com/user_exit.html
Re: Screen exit
user exit and customer exit
http://help.sap.com/saphelp_47x200/helpdata/en/dd/561602545a11d1a7020000e829fd11/frameset.htm
http://www.sap-basis-abap.com/sapab013.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
How to implement screen exit for a SAP standard transaction
Introduction
SAP provides standard transactions to enter data into database. But a client may want to maintain some additional information in SAP other than what is provided.
To make provisions for this, additional screens have to be provided and additional fields must be added into appropriate database table.
To pave way for this, SAP has provided the option for screen exits. Usually, SAP provides the following:
An append structure in the database table with the new fields.
A subscreen area into the standard screen where the programmer can attach his subscreen of his own program with the new fields.
A function group under which the new subscreen has to be created with the new fields.
Function exits to synchronize the PBO and PAI of the standard SAP program with the PBO and PAI of the subscreen so that data can flow back and forth between the standard SAP program and the program written by the developer for the subscreen. These function modules also exist in the same function group under which the subscreen will have to be developed.
Finally, a linkage has to be done between the subscreen area of standard SAP screen with the custom subscreen constructed by the developer.
Typically, SAP provides an enhancement in which the developer can create an append structure, use the function exits to synchronize the PBO and PAI of the standard SAP program and the custom subscreen program, and make the necessary linking( as mentioned above in step 4. But, again, this is not a hard and fast rule. Linking in some case, is also done by configurations.) SAP also usually provides the name of the function group under which the subscreen has to be developed.
Necessary guidance about implementing a screen exit development is usually available in the Documentation section of the enhancement ( can be availed by transaction SMOD).
Pre-Requisites
The developer to work on screen exit should have essential knowledge on the following:
DDIC concepts, including the knowledge of append structure.
Concept of SAP Enhancements and implementing them using Projects.
Concept of function exits.
Knowledge on Module Pool including subscreens, Tabstrip controls etc.
Steps
Guidelines
So, a developer can follow the guidelines mentioned below to implement a screen exit to a standard SAP transaction, as and when required:
Find out the Required Enhancements
Go to SMOD. Press F4 in the Enhancement field. In the next popup window, click pushbutton SAP Applications. A list will appear that contains information on all the enhancements, categorized under functional areas. Developer must search for the enhancements relevant to his functional area of interest for e.g., Purchasing, Asset Accounting, etc.
Note down the enhancements. Then, come to the initial screen of SMOD and view the documentation of each enhancement to find out which one is required for your development.
Utilize the Enhancement in a Project
After you have found one, do as directed in the documentation. Generally, the steps are as follows:
Create a project using CMOD including your enhancement.
Create the append structure with new fields.
Go to the desired function group and create a subscreen with the new fields. Write PBO and PAI for the subscreen, if required.
Use the function exits in the enhancement to link the PBO and PAI of the subscreen with that of the main SAP program supporting the SAP transaction.
Maintain necessary linkage between the subscreen area of standard SAP program with the custom subscreen developed along with the custom program name. This can be done in the project (developed by CMOD including the enhancement) or outside as a part of configuration.
Activate the project.
Test to ensure that required functionality are met.
Case Study 1
Add three new custom fields for Asset master and maintain information for them
Requirement
Three fields in the legacy system have to be maintained in Asset master. These fields are:
Original Asset number 20 characters
Location 2 15 Characters.
Model no 20 characters
Location 2 should start with L.
Pre-Analysis
Finding out the Enhancement
As described above, the enhancement is determined. It was found, that enhancement AIST0002 will serve the purpose. It contains the following components (can be viewed by transaction SMOD):
Exit Type Description EXIT_SAPL1022_001 Function Exit Check of User-Defined Fields when Using Create and Change BAPI EXIT_SAPLAIST_002 Function Exit Transfer Data for User Subscreens in PBO. EXIT_SAPLAIST_003 Function Exit Transfer of User-Defined Fields to SAP Master Data Transactions CI_ANLU Customizing Include Include structure to add new fields
Studying the Function Exits
The function module level documentation for the function exits are then viewed from transaction SE37. The documentation clearly laid out for the purpose for their use:
EXIT_SAPLAIST_002
Function module Level Documentation
This function module is called by asset master data maintenance at the start of the dialog. (When changing, it is called after reading of the data from the database; when creating it is called after the transfer of the default values from the asset class and reference asset.) The purpose of the function module is to enable this function group to recognize the master data. For interpreting or controlling master data fields that are important for user fields, it is possible to transfer to global variables at this point, so that they can be recognized when the user subscreens are processed.
Import Parameters
Understanding
This function module is called at the PBO to pass the information retrieved from the database to pass them to the custom subscreen and its underlying program. Import parameter : I_ANLU will be populated with the values for user-defined fields which will be passed to the subscreen program. So, there must be some sort of variable assignment from I_ANLU.
EXIT_SAPLAIST_003
Function module Documentation: This function module is called by SAP asset master data maintenance after the screens are processed, but before saving. The purpose of the function module is to transfer fields entered on user sub-screens of SAP asset data maintenance to the database for updating. The export parameter for this function module is:
Understanding
This function module will be used to transfer the user entered data in the subscreen fields to the main SAP program, which will then be saved into the database.
Studying the Documentation of the Enhancement
The enhancement documentation (as is viewed from the initial screen of SMOD] also supports the idea. Moreover, it informs that we need to develop a subscreen under function group XAIS. This is the function group under which the two function exit modules also exist. So, if the custom subscreen refers to the global data of the function group XAIS, then those values will also be available to these function exits as well.
Going to SE80 and viewing the function group XAIS helps us to inform that there are three DDIC tables declared for it:
Deciding the Final course of Action
After making all the investigations, the final course of action was determined.
SrlNo Step Justification
A project has to be created using transaction CMOD where the enhancement AIST0002 will be included.
Customizing include CI_ANLU has to be created with the custom fields demanded When CI_ANLU will be developed, the custom fields will get appended to the database table ANLU. Also, these fields will be used to create screen fields in the new subscreen.
A custom subscreen, say, 9000 will be developed under function group XAIS. The screen group for the screen will be CUST (or any name). The three custom fields added to table ANLU (by creating CI_ANLU) will be used to create new fields in the screen.
In the PAI of the subscreen, validation for Location to start with L will be added. The subscreen with three new fields has to be developed so that it can be attached to a subscreen area of the asset master screens.
In the custom include of the function exit module EXIT_SAPLAIST_002, the following code will be written:-
ANLU = I_ANLU. I_ANLU is the import parameter of this FM. The value is assigned to the global variable ANLU, referring which the three new subscreen fields are developed. So, data retrieved from database table ANLU will be passed to this FM as I_ANLU by the standard SAP main program. The value will be taken and passed to the global variable of the function group XAIS, so that the three custom fields (referring to ANLU of XAIS) get populated.
In the custom include of the function exit module EXIT_SAPLAIST_003, the following code will be written:-
E_ANLU = ANLU. The changed values in the subscreen fields exist in global variable ANLU for the function group XAIS. This function exit module will pass the data back to the SAP main program as E_ANLU.
Proper linkage/configuration has to be done so that the new subscreens get linked to the appropriate subscreen area of the Asset master screen. This has to be done otherwise, the new custom subscreen will not be displayed in the Asset master screens.
Development
Creating a Project to include the enhancement
Go to transaction CMOD and create a project.
Enter a description for the project. Then, click on the pushbutton Enhancement Assignments in the Application Toolbar.
Enter the name of the enhancement and Save.
Go to Components.
Creating Custom Include for ANLU
The screen shown below will appear, showing all the enhancement components under the assignment AIST0002. Double-click on the name of the Include Structure to create it.
Create the include structure with three new fields, as required. Then, save and activate it.
Develop the subscreen and the program
Go to transaction SE80. For the function group XAIS, create a new subscreen 9000.
Create it as subscreen.
Then, go to the Layout of the screen and create three new fields from Database table ANLU.
Drag the fields in the screen body and place them.
Then, save and activate the screen and come back to screen flow editor.
Create the PAI module to add validation for field Location 2, as required .
Activate the whole function group and come out.
Write code in the Function Exits to synchronize the programs
Now, code has to be written in the function modules EXIT_SAPLAIST_002 and EXIT_SAPLAIST_003 so that data flows to and fro between the main SAP program and custom subscreen program. For that, go back to transaction CMOD and change the function exits.
Write code in the function module EXIT_SAPLAIST_002 called once at the beginning of the transaction:
Write code in EXIT_SAPLAIST_003 to pass the data from the subscreen to SAP main program.
Then, activate everything the whole project and come out.
Complete the configuration to link the subscreen
The development portion is complete. Now, linking of the subscreen has to be done with the subscreen area of the main program. In most of the cases, this linking can be done in the enhancement itself. But, here, requirement is a bit different. It is done by configuration using SPRO.
Assets are created under Asset class. And for each asset class, there is a layout assigned to it. For a layout, there are multiple tab pages assigned to it. And, for each tab page, there are multiple screen groups/field groups assigned.
Here, the requirement is to create these three custom fields in the tab page General of asset master screen ( AS01/AS02/AS03/AS91).
Determine the Layout
To achieve this, first of all, we need to find out which layout is assigned to asset class 1000.For that, go to transaction AOLK( information has to be obtained from functional consultant).Select the Asset Class 1000 and click on folder General Assignment of Layout.
Here, for Asset class 1000, for all the user groups, tab layout SAP is assigned. Since layout SAP cannot be changed, it has to be copied and manipulated to include our screen group. Later, the new layout has to be assigned over here.
Create new tab layout
Go to transaction AOLA. Copy the tab layout SAP to create another layout, say, YSUB.
System will copy all the settings and will inform you about that.
Select your newly created layout and double-click on the folder Tab page titles.
You want to put your custom fields in the tab page General. So, select this tab page entry and double-click on the folder "Position of Groups".
Here, all the field groups currently residing in the tab-page General are shown. Add an entry for your newly created fields.
Select the group box from the list. An entry will come with U padded with the custom subscreen prepared by you.
Then, save and come out.
Assign the new Layout to Asset Class
Now, go to tcode AOLK and assign tab layout YSUB for asset class 1000.
Save and come out.
Test the Exit
Everything is over. Now, go to transaction code AS01/02/03 or AS91 to deal with an asset of asset class 1000. You will see your new fields added to the screen. Add values to them save. Then, enter into the tcodes again to see whether the values entered by you are being displayed or not.
Original Source: ittoolbox.com
MENU
refer
MEnu Exit
just refer to the link below for step by step procedure with screen shots
http://www.sapmaterial.com/?gclid=CN322K28t4sCFQ-WbgodSGbK2g
Check this link:
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975e643b111d1896f0000e8322d00/frameset.htm
Menu exits allow you to add your own functions to the pulldown menus in standard R/3 transactions. To take advantage of a menu exit, you first need to create a project as described in the section Creating an add-on project. Then, you must include the SAP enhancement package that contains the menu exit you want to use in your project. From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
The system lists all customer exits contained in the enhancements included in your project.
Place the cursor on the menu exit you want to add your own function to.
Choose Edit component.
The system displays technical information about the menu entry. It also displays two input fields where you can specify a language and the text you want your menu item to have.
Enter the name of your menu function (such as Special order method) in the field New text.
Choose Save text.
Your special menu function will not appear in the pulldown menu of the corresponding standard transaction until you activate your enhancement project.
Specifying a menu text and activating your project are not the only steps you need to take to make your own menu item work. After you carry out these steps, your menu item will appear, but it will not call a corresponding function. To attach your menu entry to its corresponding function, you need to create a function module for the function module exit associated with your menu text. This function module exit is part of the same SAP enhancement that contains the menu exit you used. Creating Customer-Specific Function Modules tells you more about how to use function module exits.
User exits (Function module exits) are exits developed by SAP. The exit is implementerd as a call to a function module. The code for the function module is written by the developer. You are not writing the code directly in the function module, but in the include that is implemented in the function module.
The naming standard of function modules for functionmodule exits is:
EXIT_<program name><3 digit suffix>
The call to a functionmodule exit is implemented as:
CALL CUSTOMER.-FUNCTION <3 digit suffix>
To find a Exit.
Goto Transaction -- Find The Package
SMOD >f4>Use the Package here to Find the Exits In the Package.
Else if you Want to search by Application Area wise ,
There is one more tab to find the Exits in the Respective Application Area.
Implementing the Exit-- CMOD Create ProjectsAssgn your Component .
Now Run ur Transaction to Check if it Triggers.
Thats it..
Suppose you need to find out all the user exits related to a tcode.
1. Execute the Tcode.
2. Open the SAP program.
3. Get the Development Class.
4. Execute Tcode SE84.
5. Open the Node 'Envir. -> Exit Techniques -> 'Customer Exits -> Enhancements'
6. Enter the Development class and execute.
Check out this thread..
The specified item was not found.
1. Type the transaction : system->status-> <PROG. NAME>
2 open SE37 , type EXIT<PROG NAME> and press F4 to get the list of function exits available.
3. Open CMOD utilities->SAP enhancements
EDIT->All selections
4.type the function module name obtained in step 2, in fields 'component name' in 'additional selections' block. and execute.
5. The displayed list contains the enhancements names for the transaction You were looking for.
6. Create a project in CMOD and the code in default include->activate.
http://www.erpgenie.com/sap/abap/code/abap26.htm
which gives the list of exits for a tcode
http://help.sap.com/saphelp_nw04/helpdata/en/bf/ec079f5db911d295ae0000e82de14a/frameset.htm
For information on Exits, check these links
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sapgenie.com/abap/code/abap26.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
http://www.easymarketplace.de/userexit.php
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sappoint.com/abap/userexit.pdfUser-Exit
http://www.planetsap.com/userexit_main_page.htm
User-Exits
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sap-img.com/ab038.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.sap-basis-abap.com/sapab013.htm
http://sap.ittoolbox.com/documents/popular-q-and-a/user-exits-for-the-transaction-code-migo-3283
These links will help you to learn more on user exits.
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975cc43b111d1896f0000e8322d00/frameset.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.allsaplinks.com/user_exit.html
www.sap-img.com/abap/what-is-user-exits.htm
Also please check these threads for more details about user exits.
Re: Screen exit
user exit and customer exit
user exit
1. Document on UserExits in FI/CO
http://www.ficoexpertonline.com/downloads/User%20ExitsWPedit.doc
2. Finding User Exits...
http://sap.ionelburlacu.ro/abap/sap2/Other_Useful_Tips.html#Finding_User_Exits
3. List of all User Exits...
http://www.planetsap.com/userexit_main_page.htm
Reward points if helpful.
Thanks
Naveen khan
Message was edited by:
Pattan Naveen -
Screen exit for me32k for header and for items
hi experts,
i need a screen exit from me32k to add subscreen in :
1. items
2. header
thanks in advanced,
dana.Hi,
Just some information on screen exits:
Screen Exit:
How to implement screen exit for a SAP standard transaction
Introduction
SAP provides standard transactions to enter data into database. But a client may want to maintain some additional information in SAP other than what is provided.
To make provisions for this, additional screens have to be provided and additional fields must be added into appropriate database table.
To pave way for this, SAP has provided the option for screen exits. Usually, SAP provides the following:
An append structure in the database table with the new fields.
A subscreen area into the standard screen where the programmer can attach his subscreen of his own program with the new fields.
A function group under which the new subscreen has to be created with the new fields.
Function exits to synchronize the PBO and PAI of the standard SAP program with the PBO and PAI of the subscreen so that data can flow back and forth between the standard SAP program and the program written by the developer for the subscreen. These function modules also exist in the same function group under which the subscreen will have to be developed.
Finally, a linkage has to be done between the subscreen area of standard SAP screen with the custom subscreen constructed by the developer.
Typically, SAP provides an enhancement in which the developer can create an append structure, use the function exits to synchronize the PBO and PAI of the standard SAP program and the custom subscreen program, and make the necessary linking( as mentioned above in step 4. But, again, this is not a hard and fast rule. Linking in some case, is also done by configurations.) SAP also usually provides the name of the function group under which the subscreen has to be developed.
Necessary guidance about implementing a screen exit development is usually available in the Documentation section of the enhancement ( can be availed by transaction SMOD).
Pre-Requisites
The developer to work on screen exit should have essential knowledge on the following:
DDIC concepts, including the knowledge of append structure.
Concept of SAP Enhancements and implementing them using Projects.
Concept of function exits.
Knowledge on Module Pool including subscreens, Tabstrip controls etc.
Steps
Guidelines
So, a developer can follow the guidelines mentioned below to implement a screen exit to a standard SAP transaction, as and when required:
Find out the Required Enhancements
Go to SMOD. Press F4 in the Enhancement field. In the next popup window, click pushbutton SAP Applications. A list will appear that contains information on all the enhancements, categorized under functional areas. Developer must search for the enhancements relevant to his functional area of interest for e.g., Purchasing, Asset Accounting, etc.
Note down the enhancements. Then, come to the initial screen of SMOD and view the documentation of each enhancement to find out which one is required for your development.
Utilize the Enhancement in a Project
After you have found one, do as directed in the documentation. Generally, the steps are as follows:
Create a project using CMOD including your enhancement.
Create the append structure with new fields.
Go to the desired function group and create a subscreen with the new fields. Write PBO and PAI for the subscreen, if required.
Use the function exits in the enhancement to link the PBO and PAI of the subscreen with that of the main SAP program supporting the SAP transaction.
Maintain necessary linkage between the subscreen area of standard SAP program with the custom subscreen developed along with the custom program name. This can be done in the project (developed by CMOD including the enhancement) or outside as a part of configuration.
Activate the project.
Test to ensure that required functionality are met.
Case Study 1
Add three new custom fields for Asset master and maintain information for them
Requirement
Three fields in the legacy system have to be maintained in Asset master. These fields are:
Original Asset number 20 characters
Location 2 15 Characters.
Model no 20 characters
Location 2 should start with L.
Pre-Analysis
Finding out the Enhancement
As described above, the enhancement is determined. It was found, that enhancement AIST0002 will serve the purpose. It contains the following components (can be viewed by transaction SMOD):
Exit Type Description EXIT_SAPL1022_001 Function Exit Check of User-Defined Fields when Using Create and Change BAPI EXIT_SAPLAIST_002 Function Exit Transfer Data for User Subscreens in PBO. EXIT_SAPLAIST_003 Function Exit Transfer of User-Defined Fields to SAP Master Data Transactions CI_ANLU Customizing Include Include structure to add new fields
Studying the Function Exits
The function module level documentation for the function exits are then viewed from transaction SE37. The documentation clearly laid out for the purpose for their use:
EXIT_SAPLAIST_002
Function module Level Documentation
This function module is called by asset master data maintenance at the start of the dialog. (When changing, it is called after reading of the data from the database; when creating it is called after the transfer of the default values from the asset class and reference asset.) The purpose of the function module is to enable this function group to recognize the master data. For interpreting or controlling master data fields that are important for user fields, it is possible to transfer to global variables at this point, so that they can be recognized when the user subscreens are processed.
Import Parameters
Understanding
This function module is called at the PBO to pass the information retrieved from the database to pass them to the custom subscreen and its underlying program. Import parameter : I_ANLU will be populated with the values for user-defined fields which will be passed to the subscreen program. So, there must be some sort of variable assignment from I_ANLU.
EXIT_SAPLAIST_003
Function module Documentation: This function module is called by SAP asset master data maintenance after the screens are processed, but before saving. The purpose of the function module is to transfer fields entered on user sub-screens of SAP asset data maintenance to the database for updating. The export parameter for this function module is:
Understanding
This function module will be used to transfer the user entered data in the subscreen fields to the main SAP program, which will then be saved into the database.
Studying the Documentation of the Enhancement
The enhancement documentation (as is viewed from the initial screen of SMOD] also supports the idea. Moreover, it informs that we need to develop a subscreen under function group XAIS. This is the function group under which the two function exit modules also exist. So, if the custom subscreen refers to the global data of the function group XAIS, then those values will also be available to these function exits as well.
Going to SE80 and viewing the function group XAIS helps us to inform that there are three DDIC tables declared for it:
Deciding the Final course of Action
After making all the investigations, the final course of action was determined.
SrlNo Step Justification
A project has to be created using transaction CMOD where the enhancement AIST0002 will be included.
Customizing include CI_ANLU has to be created with the custom fields demanded When CI_ANLU will be developed, the custom fields will get appended to the database table ANLU. Also, these fields will be used to create screen fields in the new subscreen.
A custom subscreen, say, 9000 will be developed under function group XAIS. The screen group for the screen will be CUST (or any name). The three custom fields added to table ANLU (by creating CI_ANLU) will be used to create new fields in the screen.
In the PAI of the subscreen, validation for Location to start with L will be added. The subscreen with three new fields has to be developed so that it can be attached to a subscreen area of the asset master screens.
In the custom include of the function exit module EXIT_SAPLAIST_002, the following code will be written:-
ANLU = I_ANLU. I_ANLU is the import parameter of this FM. The value is assigned to the global variable ANLU, referring which the three new subscreen fields are developed. So, data retrieved from database table ANLU will be passed to this FM as I_ANLU by the standard SAP main program. The value will be taken and passed to the global variable of the function group XAIS, so that the three custom fields (referring to ANLU of XAIS) get populated.
In the custom include of the function exit module EXIT_SAPLAIST_003, the following code will be written:-
E_ANLU = ANLU. The changed values in the subscreen fields exist in global variable ANLU for the function group XAIS. This function exit module will pass the data back to the SAP main program as E_ANLU.
Proper linkage/configuration has to be done so that the new subscreens get linked to the appropriate subscreen area of the Asset master screen. This has to be done otherwise, the new custom subscreen will not be displayed in the Asset master screens.
Development
Creating a Project to include the enhancement
Go to transaction CMOD and create a project.
Enter a description for the project. Then, click on the pushbutton Enhancement Assignments in the Application Toolbar.
Enter the name of the enhancement and Save.
Go to Components.
Creating Custom Include for ANLU
The screen shown below will appear, showing all the enhancement components under the assignment AIST0002. Double-click on the name of the Include Structure to create it.
Create the include structure with three new fields, as required. Then, save and activate it.
Develop the subscreen and the program
Go to transaction SE80. For the function group XAIS, create a new subscreen 9000.
Create it as subscreen.
Then, go to the Layout of the screen and create three new fields from Database table ANLU.
Drag the fields in the screen body and place them.
Then, save and activate the screen and come back to screen flow editor.
Create the PAI module to add validation for field Location 2, as required .
Activate the whole function group and come out.
Write code in the Function Exits to synchronize the programs
Now, code has to be written in the function modules EXIT_SAPLAIST_002 and EXIT_SAPLAIST_003 so that data flows to and fro between the main SAP program and custom subscreen program. For that, go back to transaction CMOD and change the function exits.
Write code in the function module EXIT_SAPLAIST_002 called once at the beginning of the transaction:
Write code in EXIT_SAPLAIST_003 to pass the data from the subscreen to SAP main program.
Then, activate everything the whole project and come out.
Complete the configuration to link the subscreen
The development portion is complete. Now, linking of the subscreen has to be done with the subscreen area of the main program. In most of the cases, this linking can be done in the enhancement itself. But, here, requirement is a bit different. It is done by configuration using SPRO.
Assets are created under Asset class. And for each asset class, there is a layout assigned to it. For a layout, there are multiple tab pages assigned to it. And, for each tab page, there are multiple screen groups/field groups assigned.
Here, the requirement is to create these three custom fields in the tab page General of asset master screen ( AS01/AS02/AS03/AS91).
Determine the Layout
To achieve this, first of all, we need to find out which layout is assigned to asset class 1000.For that, go to transaction AOLK( information has to be obtained from functional consultant).Select the Asset Class 1000 and click on folder General Assignment of Layout.
Here, for Asset class 1000, for all the user groups, tab layout SAP is assigned. Since layout SAP cannot be changed, it has to be copied and manipulated to include our screen group. Later, the new layout has to be assigned over here.
Create new tab layout
Go to transaction AOLA. Copy the tab layout SAP to create another layout, say, YSUB.
System will copy all the settings and will inform you about that.
Select your newly created layout and double-click on the folder Tab page titles.
You want to put your custom fields in the tab page General. So, select this tab page entry and double-click on the folder "Position of Groups".
Here, all the field groups currently residing in the tab-page General are shown. Add an entry for your newly created fields.
Select the group box from the list. An entry will come with U padded with the custom subscreen prepared by you.
Then, save and come out.
Assign the new Layout to Asset Class
Now, go to tcode AOLK and assign tab layout YSUB for asset class 1000.
Save and come out.
Test the Exit
Everything is over. Now, go to transaction code AS01/02/03 or AS91 to deal with an asset of asset class 1000. You will see your new fields added to the screen. Add values to them save. Then, enter into the tcodes again to see whether the values entered by you are being displayed or not.
Original Source: ittoolbox.com
User Exits:
User exits (Function module exits) are exits developed by SAP. The exit is implementerd as a call to a function module. The code for the function module is written by the developer. You are not writing the code directly in the function module, but in the include that is implemented in the function module.
The naming standard of function modules for functionmodule exits is:
EXIT_<program name><3 digit suffix>
The call to a functionmodule exit is implemented as:
CALL CUSTOMER.-FUNCTION <3 digit suffix>
To find a Exit.
Goto Transaction -- Find The Package
SMOD >f4>Use the Package here to Find the Exits In the Package.
Else if you Want to search by Application Area wise ,
There is one more tab to find the Exits in the Respective Application Area.
Implementing the Exit-- CMOD Create ProjectsAssgn your Component .
Now Run ur Transaction to Check if it Triggers.
Thats it..
Suppose you need to find out all the user exits related to a tcode.
1. Execute the Tcode.
2. Open the SAP program.
3. Get the Development Class.
4. Execute Tcode SE84.
5. Open the Node 'Envir. -> Exit Techniques -> 'Customer Exits -> Enhancements'
6. Enter the Development class and execute.
Check out this thread..
The specified item was not found.
1. Type the transaction : system->status-> <PROG. NAME>
2 open SE37 , type EXIT<PROG NAME> and press F4 to get the list of function exits available.
3. Open CMOD utilities->SAP enhancements
EDIT->All selections
4.type the function module name obtained in step 2, in fields 'component name' in 'additional selections' block. and execute.
5. The displayed list contains the enhancements names for the transaction You were looking for.
6. Create a project in CMOD and the code in default include->activate.
http://www.erpgenie.com/sap/abap/code/abap26.htm
which gives the list of exits for a tcode
http://help.sap.com/saphelp_nw04/helpdata/en/bf/ec079f5db911d295ae0000e82de14a/frameset.htm
For information on Exits, check these links
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sapgenie.com/abap/code/abap26.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
http://www.easymarketplace.de/userexit.php
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sappoint.com/abap/userexit.pdfUser-Exit
http://www.planetsap.com/userexit_main_page.htm
User-Exits
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sap-img.com/ab038.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.sap-basis-abap.com/sapab013.htm
http://sap.ittoolbox.com/documents/popular-q-and-a/user-exits-for-the-transaction-code-migo-3283
These links will help you to learn more on user exits.
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975cc43b111d1896f0000e8322d00/frameset.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.allsaplinks.com/user_exit.html
www.sap-img.com/abap/what-is-user-exits.htm
Also please check these threads for more details about user exits.
Re: Screen exit
user exit and customer exit
user exit
1. Document on UserExits in FI/CO
http://www.ficoexpertonline.com/downloads/User%20ExitsWPedit.doc
2. Finding User Exits...
http://sap.ionelburlacu.ro/abap/sap2/Other_Useful_Tips.html#Finding_User_Exits
3. List of all User Exits...
http://www.planetsap.com/userexit_main_page.htm
Reward if found helpfull,
Cheers,
Chaitanya. -
Hi Friends,
I created the sales order using VA01 and enter the payment terms and saved. But mu requirement is when i go through VA02, payment terms field must be in display mode. So, user not able to chage the payment terms value.
Please give exact solution with Screen exit name and modifications.
Thanks in advance
Regards
Govind.Hi,
The SAPMV45A , 8309 screen is the Additional Data B tab providded by SAP to add your custom fields . In order to capture the data from this custon field you can use
the user exit MV45AFZZ, USEREXIT_SAVE_DOCUMENT_PREPARE OR
USEREXIT_SAVE_DOCUMENT depening on your functionality.
If you include the field MGANR as a part of the VBRK /VBRP structure then these will be available.
step by step method to implement screen exit:
Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen
Regards -
want some examples and step by step guide for menu exits and screen exits.
Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen
check the foll link,
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
Menu exits allow you to add your own functions to the pulldown menus in standard R/3 transactions. To take advantage of a menu exit, you first need to create a project as described in the section Creating an add-on project. Then, you must include the SAP enhancement package that contains the menu exit you want to use in your project. From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
The system lists all customer exits contained in the enhancements included in your project.
Place the cursor on the menu exit you want to add your own function to.
Choose Edit component.
The system displays technical information about the menu entry. It also displays two input fields where you can specify a language and the text you want your menu item to have.
Enter the name of your menu function (such as Special order method) in the field New text.
Choose Save text.
Your special menu function will not appear in the pulldown menu of the corresponding standard transaction until you activate your enhancement project.
Specifying a menu text and activating your project are not the only steps you need to take to make your own menu item work. After you carry out these steps, your menu item will appear, but it will not call a corresponding function. To attach your menu entry to its corresponding function, you need to create a function module for the function module exit associated with your menu text. This function module exit is part of the same SAP enhancement that contains the menu exit you used. Creating Customer-Specific Function Modules tells you more about how to use function module exits.
also refer
MEnu Exit
http://www.sap-img.com/abap/what-is-user-exits.htm
Creating menu exits
http://help.sap.com/saphelp_nw04/helpdata/en/c8/19762743b111d1896f0000e8322d00/content.htm
http://help.sap.com/saphelp_nw2004s/helpdata/en/83/7a18cbde6e11d195460000e82de14a/frameset.htm
For screen exits.
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
chech these links for user exists its usefull
http://www.allsaplinks.com/user_exit.html
Re: Screen exit
user exit and customer exit
http://help.sap.com/saphelp_47x200/helpdata/en/dd/561602545a11d1a7020000e829fd11/frameset.htm
http://www.sap-basis-abap.com/sapab013.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
How to implement screen exit for a SAP standard transaction
Introduction
SAP provides standard transactions to enter data into database. But a client may want to maintain some additional information in SAP other than what is provided.
To make provisions for this, additional screens have to be provided and additional fields must be added into appropriate database table.
To pave way for this, SAP has provided the option for screen exits. Usually, SAP provides the following:
An append structure in the database table with the new fields.
A subscreen area into the standard screen where the programmer can attach his subscreen of his own program with the new fields.
A function group under which the new subscreen has to be created with the new fields.
Function exits to synchronize the PBO and PAI of the standard SAP program with the PBO and PAI of the subscreen so that data can flow back and forth between the standard SAP program and the program written by the developer for the subscreen. These function modules also exist in the same function group under which the subscreen will have to be developed.
Finally, a linkage has to be done between the subscreen area of standard SAP screen with the custom subscreen constructed by the developer.
Typically, SAP provides an enhancement in which the developer can create an append structure, use the function exits to synchronize the PBO and PAI of the standard SAP program and the custom subscreen program, and make the necessary linking( as mentioned above in step 4. But, again, this is not a hard and fast rule. Linking in some case, is also done by configurations.) SAP also usually provides the name of the function group under which the subscreen has to be developed.
Necessary guidance about implementing a screen exit development is usually available in the Documentation section of the enhancement ( can be availed by transaction SMOD).
Pre-Requisites
The developer to work on screen exit should have essential knowledge on the following:
DDIC concepts, including the knowledge of append structure.
Concept of SAP Enhancements and implementing them using Projects.
Concept of function exits.
Knowledge on Module Pool including subscreens, Tabstrip controls etc.
Steps
Guidelines
So, a developer can follow the guidelines mentioned below to implement a screen exit to a standard SAP transaction, as and when required:
Find out the Required Enhancements
Go to SMOD. Press F4 in the Enhancement field. In the next popup window, click pushbutton SAP Applications. A list will appear that contains information on all the enhancements, categorized under functional areas. Developer must search for the enhancements relevant to his functional area of interest for e.g., Purchasing, Asset Accounting, etc.
Note down the enhancements. Then, come to the initial screen of SMOD and view the documentation of each enhancement to find out which one is required for your development.
Utilize the Enhancement in a Project
After you have found one, do as directed in the documentation. Generally, the steps are as follows:
Create a project using CMOD including your enhancement.
Create the append structure with new fields.
Go to the desired function group and create a subscreen with the new fields. Write PBO and PAI for the subscreen, if required.
Use the function exits in the enhancement to link the PBO and PAI of the subscreen with that of the main SAP program supporting the SAP transaction.
Maintain necessary linkage between the subscreen area of standard SAP program with the custom subscreen developed along with the custom program name. This can be done in the project (developed by CMOD including the enhancement) or outside as a part of configuration.
Activate the project.
Test to ensure that required functionality are met.
Case Study 1
Add three new custom fields for Asset master and maintain information for them
Requirement
Three fields in the legacy system have to be maintained in Asset master. These fields are:
Original Asset number 20 characters
Location 2 15 Characters.
Model no 20 characters
Location 2 should start with L.
Pre-Analysis
Finding out the Enhancement
As described above, the enhancement is determined. It was found, that enhancement AIST0002 will serve the purpose. It contains the following components (can be viewed by transaction SMOD):
Exit Type Description EXIT_SAPL1022_001 Function Exit Check of User-Defined Fields when Using Create and Change BAPI EXIT_SAPLAIST_002 Function Exit Transfer Data for User Subscreens in PBO. EXIT_SAPLAIST_003 Function Exit Transfer of User-Defined Fields to SAP Master Data Transactions CI_ANLU Customizing Include Include structure to add new fields
Studying the Function Exits
The function module level documentation for the function exits are then viewed from transaction SE37. The documentation clearly laid out for the purpose for their use:
EXIT_SAPLAIST_002
Function module Level Documentation
This function module is called by asset master data maintenance at the start of the dialog. (When changing, it is called after reading of the data from the database; when creating it is called after the transfer of the default values from the asset class and reference asset.) The purpose of the function module is to enable this function group to recognize the master data. For interpreting or controlling master data fields that are important for user fields, it is possible to transfer to global variables at this point, so that they can be recognized when the user subscreens are processed.
Import Parameters
Understanding
This function module is called at the PBO to pass the information retrieved from the database to pass them to the custom subscreen and its underlying program. Import parameter : I_ANLU will be populated with the values for user-defined fields which will be passed to the subscreen program. So, there must be some sort of variable assignment from I_ANLU.
EXIT_SAPLAIST_003
Function module Documentation: This function module is called by SAP asset master data maintenance after the screens are processed, but before saving. The purpose of the function module is to transfer fields entered on user sub-screens of SAP asset data maintenance to the database for updating. The export parameter for this function module is:
Understanding
This function module will be used to transfer the user entered data in the subscreen fields to the main SAP program, which will then be saved into the database.
Studying the Documentation of the Enhancement
The enhancement documentation (as is viewed from the initial screen of SMOD] also supports the idea. Moreover, it informs that we need to develop a subscreen under function group XAIS. This is the function group under which the two function exit modules also exist. So, if the custom subscreen refers to the global data of the function group XAIS, then those values will also be available to these function exits as well.
Going to SE80 and viewing the function group XAIS helps us to inform that there are three DDIC tables declared for it:
Deciding the Final course of Action
After making all the investigations, the final course of action was determined.
SrlNo Step Justification
A project has to be created using transaction CMOD where the enhancement AIST0002 will be included.
Customizing include CI_ANLU has to be created with the custom fields demanded When CI_ANLU will be developed, the custom fields will get appended to the database table ANLU. Also, these fields will be used to create screen fields in the new subscreen.
A custom subscreen, say, 9000 will be developed under function group XAIS. The screen group for the screen will be CUST (or any name). The three custom fields added to table ANLU (by creating CI_ANLU) will be used to create new fields in the screen.
In the PAI of the subscreen, validation for Location to start with L will be added. The subscreen with three new fields has to be developed so that it can be attached to a subscreen area of the asset master screens.
In the custom include of the function exit module EXIT_SAPLAIST_002, the following code will be written:-
ANLU = I_ANLU. I_ANLU is the import parameter of this FM. The value is assigned to the global variable ANLU, referring which the three new subscreen fields are developed. So, data retrieved from database table ANLU will be passed to this FM as I_ANLU by the standard SAP main program. The value will be taken and passed to the global variable of the function group XAIS, so that the three custom fields (referring to ANLU of XAIS) get populated.
In the custom include of the function exit module EXIT_SAPLAIST_003, the following code will be written:-
E_ANLU = ANLU. The changed values in the subscreen fields exist in global variable ANLU for the function group XAIS. This function exit module will pass the data back to the SAP main program as E_ANLU.
Proper linkage/configuration has to be done so that the new subscreens get linked to the appropriate subscreen area of the Asset master screen. This has to be done otherwise, the new custom subscreen will not be displayed in the Asset master screens.
Development
Creating a Project to include the enhancement
Go to transaction CMOD and create a project.
Enter a description for the project. Then, click on the pushbutton Enhancement Assignments in the Application Toolbar.
Enter the name of the enhancement and Save.
Go to Components.
Creating Custom Include for ANLU
The screen shown below will appear, showing all the enhancement components under the assignment AIST0002. Double-click on the name of the Include Structure to create it.
Create the include structure with three new fields, as required. Then, save and activate it.
Develop the subscreen and the program
Go to transaction SE80. For the function group XAIS, create a new subscreen 9000.
Create it as subscreen.
Then, go to the Layout of the screen and create three new fields from Database table ANLU.
Drag the fields in the screen body and place them.
Then, save and activate the screen and come back to screen flow editor.
Create the PAI module to add validation for field Location 2, as required .
Activate the whole function group and come out.
Write code in the Function Exits to synchronize the programs
Now, code has to be written in the function modules EXIT_SAPLAIST_002 and EXIT_SAPLAIST_003 so that data flows to and fro between the main SAP program and custom subscreen program. For that, go back to transaction CMOD and change the function exits.
Write code in the function module EXIT_SAPLAIST_002 called once at the beginning of the transaction:
Write code in EXIT_SAPLAIST_003 to pass the data from the subscreen to SAP main program.
Then, activate everything the whole project and come out.
Complete the configuration to link the subscreen
The development portion is complete. Now, linking of the subscreen has to be done with the subscreen area of the main program. In most of the cases, this linking can be done in the enhancement itself. But, here, requirement is a bit different. It is done by configuration using SPRO.
Assets are created under Asset class. And for each asset class, there is a layout assigned to it. For a layout, there are multiple tab pages assigned to it. And, for each tab page, there are multiple screen groups/field groups assigned.
Here, the requirement is to create these three custom fields in the tab page General of asset master screen ( AS01/AS02/AS03/AS91).
Determine the Layout
To achieve this, first of all, we need to find out which layout is assigned to asset class 1000.For that, go to transaction AOLK( information has to be obtained from functional consultant).Select the Asset Class 1000 and click on folder General Assignment of Layout.
Here, for Asset class 1000, for all the user groups, tab layout SAP is assigned. Since layout SAP cannot be changed, it has to be copied and manipulated to include our screen group. Later, the new layout has to be assigned over here.
Create new tab layout
Go to transaction AOLA. Copy the tab layout SAP to create another layout, say, YSUB.
System will copy all the settings and will inform you about that.
Select your newly created layout and double-click on the folder Tab page titles.
You want to put your custom fields in the tab page General. So, select this tab page entry and double-click on the folder "Position of Groups".
Here, all the field groups currently residing in the tab-page General are shown. Add an entry for your newly created fields.
Select the group box from the list. An entry will come with U padded with the custom subscreen prepared by you.
Then, save and come out.
Assign the new Layout to Asset Class
Now, go to tcode AOLK and assign tab layout YSUB for asset class 1000.
Save and come out.
Test the Exit
Everything is over. Now, go to transaction code AS01/02/03 or AS91 to deal with an asset of asset class 1000. You will see your new fields added to the screen. Add values to them save. Then, enter into the tcodes again to see whether the values entered by you are being displayed or not.
Original Source: ittoolbox.com
MENU
refer
MEnu Exit
just refer to the link below for step by step procedure with screen shots
http://www.sapmaterial.com/?gclid=CN322K28t4sCFQ-WbgodSGbK2g
Check this link:
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975e643b111d1896f0000e8322d00/frameset.htm
Menu exits allow you to add your own functions to the pulldown menus in standard R/3 transactions. To take advantage of a menu exit, you first need to create a project as described in the section Creating an add-on project. Then, you must include the SAP enhancement package that contains the menu exit you want to use in your project. From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
The system lists all customer exits contained in the enhancements included in your project.
Place the cursor on the menu exit you want to add your own function to.
Choose Edit component.
The system displays technical information about the menu entry. It also displays two input fields where you can specify a language and the text you want your menu item to have.
Enter the name of your menu function (such as Special order method) in the field New text.
Choose Save text.
Your special menu function will not appear in the pulldown menu of the corresponding standard transaction until you activate your enhancement project.
Specifying a menu text and activating your project are not the only steps you need to take to make your own menu item work. After you carry out these steps, your menu item will appear, but it will not call a corresponding function. To attach your menu entry to its corresponding function, you need to create a function module for the function module exit associated with your menu text. This function module exit is part of the same SAP enhancement that contains the menu exit you used. Creating Customer-Specific Function Modules tells you more about how to use function module exits.
User exits (Function module exits) are exits developed by SAP. The exit is implementerd as a call to a function module. The code for the function module is written by the developer. You are not writing the code directly in the function module, but in the include that is implemented in the function module.
The naming standard of function modules for functionmodule exits is:
EXIT_<program name><3 digit suffix>
The call to a functionmodule exit is implemented as:
CALL CUSTOMER.-FUNCTION <3 digit suffix>
To find a Exit.
Goto Transaction -- Find The Package
SMOD >f4>Use the Package here to Find the Exits In the Package.
Else if you Want to search by Application Area wise ,
There is one more tab to find the Exits in the Respective Application Area.
Implementing the Exit-- CMOD Create ProjectsAssgn your Component .
Now Run ur Transaction to Check if it Triggers.
Thats it..
Suppose you need to find out all the user exits related to a tcode.
1. Execute the Tcode.
2. Open the SAP program.
3. Get the Development Class.
4. Execute Tcode SE84.
5. Open the Node 'Envir. -> Exit Techniques -> 'Customer Exits -> Enhancements'
6. Enter the Development class and execute.
Check out this thread..
The specified item was not found.
1. Type the transaction : system->status-> <PROG. NAME>
2 open SE37 , type EXIT<PROG NAME> and press F4 to get the list of function exits available.
3. Open CMOD utilities->SAP enhancements
EDIT->All selections
4.type the function module name obtained in step 2, in fields 'component name' in 'additional selections' block. and execute.
5. The displayed list contains the enhancements names for the transaction You were looking for.
6. Create a project in CMOD and the code in default include->activate.
http://www.erpgenie.com/sap/abap/code/abap26.htm
which gives the list of exits for a tcode
http://help.sap.com/saphelp_nw04/helpdata/en/bf/ec079f5db911d295ae0000e82de14a/frameset.htm
For information on Exits, check these links
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sapgenie.com/abap/code/abap26.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
http://www.easymarketplace.de/userexit.php
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sappoint.com/abap/userexit.pdfUser-Exit
http://www.planetsap.com/userexit_main_page.htm
User-Exits
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sap-img.com/ab038.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.sap-basis-abap.com/sapab013.htm
http://sap.ittoolbox.com/documents/popular-q-and-a/user-exits-for-the-transaction-code-migo-3283
These links will help you to learn more on user exits.
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975cc43b111d1896f0000e8322d00/frameset.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.allsaplinks.com/user_exit.html
www.sap-img.com/abap/what-is-user-exits.htm
Also please check these threads for more details about user exits.
Re: Screen exit
user exit and customer exit
user exit
1. Document on UserExits in FI/CO
http://www.ficoexpertonline.com/downloads/User%20ExitsWPedit.doc
2. Finding User Exits...
http://sap.ionelburlacu.ro/abap/sap2/Other_Useful_Tips.html#Finding_User_Exits
3. List of all User Exits...
http://www.planetsap.com/userexit_main_page.htm
Reward points for useful Answers -
Hi PPL,
Can anybody help me out in explaining me how to find a menu exit or the
Screen exit in a program...I have an requirement where i need to use both of them..
I have already posted this query , but people responded with links which had the
information on these two , but not the way to locate these...
I ll be very grateful for ur advice.
Regards,
Kevin Nick.hi kevin
<b>Screen exits</b> are exits that allow you to use a reserved part of the screen (A subscreen) to display or input data.
It is determined be SAP where the sub screen will be displayed.
The syntax is: CALL CUSTOMER-SUBSCREEN
The screen exit is not processed untill the corresponding subscreen has been created in an enhancement project, and the project has been activated.
Note:
Function codes are only processed in the main screens flow logic
You are not allowed to enter a name for the subscreens command field
You are not allowed to define GUI stauses
You are not allowed to enter a value for Next screen
The global data of the program is not available for the subscreen. Data for the subscreen is provided by function modules. These function modules belongs to the same function group as the subscreen
Subscreens are edited with transaction CMOD. When you activate a project containg subscreens, the calling screen is regenerated and the subscreen is displayed next time you display the calling screen
The developer must create the subscreen and the corresponding PBO and PAI modules
How to identify screen exits
Look after CALL CUSTOMER-SUBSCREEN in the screenprogram of the screen you want to modify.
Use transaction CMOD menu Utillities -> SAP enhancements to search for screen exits
<b>MENU EXITS</b>
Menu exits allow you to add your own functionallity to menus. Menu exits are implemented by SAP, and are reserved menu entries in the GUI interface. The developer can add his/her own text and logic for the menu.
Function codes for menu exits all start with "+"
Example
We want to create a new menu item in the Office menu. The text for the menu should be "Run ZTEST", and the menu will
run report ZTEST.
Goto transaction SE43 Area Menu Maintenance
In Area Menu Paramenter type 'S000' (S triple Zero)
Select Change and ignore all the warning screens
Expand the office menu. In the buttom of the office tree you will find a menu named "Customer function"
Double click on the text. In the pop-up screen change the text to "Run ZTEST". Note that the trsnaction code is +C01
Goto transaction SE93 and create transaction +C01 that calls report ZTEST.
Now you will se the menu displayed in the office tree. If you delete transaction +C01 again, the new menu will dissapear.
USER EXITS
User exits (Function module exits) are exits developed by SAP. The exit is implementerd as a call to a functionmodule. The code for the function module is writeen by the developer. You are not writing the code directly in the function module, but in the include that is implemented in the function module.
The naming standard of function modules for functionmodule exits is: EXIT_<program name><3 digit suffix>
The call to a functionmodule exit is implemented as: CALL CUSTOMER.-FUNCTION <3 digit suffix>
Example:
The program for transaction VA01 Create salesorder is SAPMV45A
If you search for CALL CUSTOMER-FUNCTION i program SAPMV45A you will find ( Among other user exits):
CALL CUSTOMER-FUNCTION '003'
exporting
xvbak = vbak
xvbuk = vbuk
xkomk = tkomk
importing
lvf_subrc = lvf_subrc
tables
xvbfa = xvbfa
xvbap = xvbap
xvbup = xvbup.
The exit calls function module EXIT_SAPMV45A_003
2. How to find user exits
Display the program where you are searching for and exit and search for CALL CUSTOMER-EXIT
If you know the Exit name, go to transaction CMOD. Choose menu Utillities->SAP Enhancements. Enter the exit name and press enter.
You will now come to a screen that shows the function module exits for the exit.
3. Using Project management of SAP Enhancements
We want to create a project to enahance trasnaction VA01
Go to transaction CMOD
Create a project called ZVA01
Choose the Enhancement assign radio button and press the Change button
In the first column enter V45A0002 Predefine sold-to party in sales document . Note that an enhancement can only be used i 1 project. If the enhancement is allready in use, and error message will be displayed
Press Save
Press Components. You can now see that enhancement uses user exit EXIT_SAPMV45A_002. Double click on the exit.
Now the function module is displayed. Double click on include ZXVVAU04 in the function module
Insert the following code into the include: E_KUNNR = '2155'.
Activate the include program. Go back to CMOD and activate the project.
Goto transaction VA01 and craete a salesorder. Note that Sold-to-party now automatically is "2155"
regards
ravish
plz reward <b>points</b> if helpful -
Hi ppl,
can neone tell me how can I find the screen exits in VA02 (screen 4459/4462)Hi,
Welcome to SDN.
Please check this link.
http://help.sap.com/saphelp_46c/helpdata/en/1c/f62c7dd435d1118b3f0060b03ca329/content.htm
Screen 8459 in program SAPMV45A is the additional data B tab to add your custom fields. In order to capture the data from this custon field you can use user exit USEREXIT_SAVE_DOCUMENT_PREPARE OR
USEREXIT_SAVE_DOCUMENT in program MV45AFZZ.
implement screen exit step by step:
Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen
Regards -
Send some document and link to screen exit
send [email protected]
enhancement document
Regarding
anilthis will give u clear picture.
Screen Exit:
How to implement screen exit for a SAP standard transaction
Introduction
SAP provides standard transactions to enter data into database. But a client may want to maintain some additional information in SAP other than what is provided.
To make provisions for this, additional screens have to be provided and additional fields must be added into appropriate database table.
To pave way for this, SAP has provided the option for screen exits. Usually, SAP provides the following:
An append structure in the database table with the new fields.
A subscreen area into the standard screen where the programmer can attach his subscreen of his own program with the new fields.
A function group under which the new subscreen has to be created with the new fields.
Function exits to synchronize the PBO and PAI of the standard SAP program with the PBO and PAI of the subscreen so that data can flow back and forth between the standard SAP program and the program written by the developer for the subscreen. These function modules also exist in the same function group under which the subscreen will have to be developed.
Finally, a linkage has to be done between the subscreen area of standard SAP screen with the custom subscreen constructed by the developer.
Typically, SAP provides an enhancement in which the developer can create an append structure, use the function exits to synchronize the PBO and PAI of the standard SAP program and the custom subscreen program, and make the necessary linking( as mentioned above in step 4. But, again, this is not a hard and fast rule. Linking in some case, is also done by configurations.) SAP also usually provides the name of the function group under which the subscreen has to be developed.
Necessary guidance about implementing a screen exit development is usually available in the Documentation section of the enhancement ( can be availed by transaction SMOD).
Pre-Requisites
The developer to work on screen exit should have essential knowledge on the following:
DDIC concepts, including the knowledge of append structure.
Concept of SAP Enhancements and implementing them using Projects.
Concept of function exits.
Knowledge on Module Pool including subscreens, Tabstrip controls etc.
Steps
Guidelines
So, a developer can follow the guidelines mentioned below to implement a screen exit to a standard SAP transaction, as and when required:
Find out the Required Enhancements
Go to SMOD. Press F4 in the Enhancement field. In the next popup window, click pushbutton SAP Applications. A list will appear that contains information on all the enhancements, categorized under functional areas. Developer must search for the enhancements relevant to his functional area of interest for e.g., Purchasing, Asset Accounting, etc.
Note down the enhancements. Then, come to the initial screen of SMOD and view the documentation of each enhancement to find out which one is required for your development.
Utilize the Enhancement in a Project
After you have found one, do as directed in the documentation. Generally, the steps are as follows:
Create a project using CMOD including your enhancement.
Create the append structure with new fields.
Go to the desired function group and create a subscreen with the new fields. Write PBO and PAI for the subscreen, if required.
Use the function exits in the enhancement to link the PBO and PAI of the subscreen with that of the main SAP program supporting the SAP transaction.
Maintain necessary linkage between the subscreen area of standard SAP program with the custom subscreen developed along with the custom program name. This can be done in the project (developed by CMOD including the enhancement) or outside as a part of configuration.
Activate the project.
Test to ensure that required functionality are met.
Case Study 1
Add three new custom fields for Asset master and maintain information for them
Requirement
Three fields in the legacy system have to be maintained in Asset master. These fields are:
Original Asset number 20 characters
Location 2 15 Characters.
Model no 20 characters
Location 2 should start with L.
Pre-Analysis
Finding out the Enhancement
As described above, the enhancement is determined. It was found, that enhancement AIST0002 will serve the purpose. It contains the following components (can be viewed by transaction SMOD):
Exit Type Description EXIT_SAPL1022_001 Function Exit Check of User-Defined Fields when Using Create and Change BAPI EXIT_SAPLAIST_002 Function Exit Transfer Data for User Subscreens in PBO. EXIT_SAPLAIST_003 Function Exit Transfer of User-Defined Fields to SAP Master Data Transactions CI_ANLU Customizing Include Include structure to add new fields
Studying the Function Exits
The function module level documentation for the function exits are then viewed from transaction SE37. The documentation clearly laid out for the purpose for their use:
EXIT_SAPLAIST_002
Function module Level Documentation
This function module is called by asset master data maintenance at the start of the dialog. (When changing, it is called after reading of the data from the database; when creating it is called after the transfer of the default values from the asset class and reference asset.) The purpose of the function module is to enable this function group to recognize the master data. For interpreting or controlling master data fields that are important for user fields, it is possible to transfer to global variables at this point, so that they can be recognized when the user subscreens are processed.
Import Parameters
Understanding
This function module is called at the PBO to pass the information retrieved from the database to pass them to the custom subscreen and its underlying program. Import parameter : I_ANLU will be populated with the values for user-defined fields which will be passed to the subscreen program. So, there must be some sort of variable assignment from I_ANLU.
EXIT_SAPLAIST_003
Function module Documentation: This function module is called by SAP asset master data maintenance after the screens are processed, but before saving. The purpose of the function module is to transfer fields entered on user sub-screens of SAP asset data maintenance to the database for updating. The export parameter for this function module is:
Understanding
This function module will be used to transfer the user entered data in the subscreen fields to the main SAP program, which will then be saved into the database.
Studying the Documentation of the Enhancement
The enhancement documentation (as is viewed from the initial screen of SMOD] also supports the idea. Moreover, it informs that we need to develop a subscreen under function group XAIS. This is the function group under which the two function exit modules also exist. So, if the custom subscreen refers to the global data of the function group XAIS, then those values will also be available to these function exits as well.
Going to SE80 and viewing the function group XAIS helps us to inform that there are three DDIC tables declared for it:
Deciding the Final course of Action
After making all the investigations, the final course of action was determined.
SrlNo Step Justification
A project has to be created using transaction CMOD where the enhancement AIST0002 will be included.
Customizing include CI_ANLU has to be created with the custom fields demanded When CI_ANLU will be developed, the custom fields will get appended to the database table ANLU. Also, these fields will be used to create screen fields in the new subscreen.
A custom subscreen, say, 9000 will be developed under function group XAIS. The screen group for the screen will be CUST (or any name). The three custom fields added to table ANLU (by creating CI_ANLU) will be used to create new fields in the screen.
In the PAI of the subscreen, validation for Location to start with L will be added. The subscreen with three new fields has to be developed so that it can be attached to a subscreen area of the asset master screens.
In the custom include of the function exit module EXIT_SAPLAIST_002, the following code will be written:-
ANLU = I_ANLU. I_ANLU is the import parameter of this FM. The value is assigned to the global variable ANLU, referring which the three new subscreen fields are developed. So, data retrieved from database table ANLU will be passed to this FM as I_ANLU by the standard SAP main program. The value will be taken and passed to the global variable of the function group XAIS, so that the three custom fields (referring to ANLU of XAIS) get populated.
In the custom include of the function exit module EXIT_SAPLAIST_003, the following code will be written:-
E_ANLU = ANLU. The changed values in the subscreen fields exist in global variable ANLU for the function group XAIS. This function exit module will pass the data back to the SAP main program as E_ANLU.
Proper linkage/configuration has to be done so that the new subscreens get linked to the appropriate subscreen area of the Asset master screen. This has to be done otherwise, the new custom subscreen will not be displayed in the Asset master screens.
Development
Creating a Project to include the enhancement
Go to transaction CMOD and create a project.
Enter a description for the project. Then, click on the pushbutton Enhancement Assignments in the Application Toolbar.
Enter the name of the enhancement and Save.
Go to Components.
Creating Custom Include for ANLU
The screen shown below will appear, showing all the enhancement components under the assignment AIST0002. Double-click on the name of the Include Structure to create it.
Create the include structure with three new fields, as required. Then, save and activate it.
Develop the subscreen and the program
Go to transaction SE80. For the function group XAIS, create a new subscreen 9000.
Create it as subscreen.
Then, go to the Layout of the screen and create three new fields from Database table ANLU.
Drag the fields in the screen body and place them.
Then, save and activate the screen and come back to screen flow editor.
Create the PAI module to add validation for field Location 2, as required .
Activate the whole function group and come out.
Write code in the Function Exits to synchronize the programs
Now, code has to be written in the function modules EXIT_SAPLAIST_002 and EXIT_SAPLAIST_003 so that data flows to and fro between the main SAP program and custom subscreen program. For that, go back to transaction CMOD and change the function exits.
Write code in the function module EXIT_SAPLAIST_002 called once at the beginning of the transaction:
Write code in EXIT_SAPLAIST_003 to pass the data from the subscreen to SAP main program.
Then, activate everything the whole project and come out.
Complete the configuration to link the subscreen
The development portion is complete. Now, linking of the subscreen has to be done with the subscreen area of the main program. In most of the cases, this linking can be done in the enhancement itself. But, here, requirement is a bit different. It is done by configuration using SPRO.
Assets are created under Asset class. And for each asset class, there is a layout assigned to it. For a layout, there are multiple tab pages assigned to it. And, for each tab page, there are multiple screen groups/field groups assigned.
Here, the requirement is to create these three custom fields in the tab page General of asset master screen ( AS01/AS02/AS03/AS91).
Determine the Layout
To achieve this, first of all, we need to find out which layout is assigned to asset class 1000.For that, go to transaction AOLK( information has to be obtained from functional consultant).Select the Asset Class 1000 and click on folder General Assignment of Layout.
Here, for Asset class 1000, for all the user groups, tab layout SAP is assigned. Since layout SAP cannot be changed, it has to be copied and manipulated to include our screen group. Later, the new layout has to be assigned over here.
Create new tab layout
Go to transaction AOLA. Copy the tab layout SAP to create another layout, say, YSUB.
System will copy all the settings and will inform you about that.
Select your newly created layout and double-click on the folder Tab page titles.
You want to put your custom fields in the tab page General. So, select this tab page entry and double-click on the folder "Position of Groups".
Here, all the field groups currently residing in the tab-page General are shown. Add an entry for your newly created fields.
Select the group box from the list. An entry will come with U padded with the custom subscreen prepared by you.
Then, save and come out.
Assign the new Layout to Asset Class
Now, go to tcode AOLK and assign tab layout YSUB for asset class 1000.
Save and come out.
Test the Exit
Everything is over. Now, go to transaction code AS01/02/03 or AS91 to deal with an asset of asset class 1000. You will see your new fields added to the screen. Add values to them save. Then, enter into the tcodes again to see whether the values entered by you are being displayed or not.
Original Source: ittoolbox.com
User Exits:
User exits (Function module exits) are exits developed by SAP. The exit is implementerd as a call to a function module. The code for the function module is written by the developer. You are not writing the code directly in the function module, but in the include that is implemented in the function module.
The naming standard of function modules for functionmodule exits is:
EXIT_<program name><3 digit suffix>
The call to a functionmodule exit is implemented as:
CALL CUSTOMER.-FUNCTION <3 digit suffix>
To find a Exit.
Goto Transaction -- Find The Package
SMOD >f4>Use the Package here to Find the Exits In the Package.
Else if you Want to search by Application Area wise ,
There is one more tab to find the Exits in the Respective Application Area.
Implementing the Exit-- CMOD Create ProjectsAssgn your Component .
Now Run ur Transaction to Check if it Triggers.
Thats it..
Suppose you need to find out all the user exits related to a tcode.
1. Execute the Tcode.
2. Open the SAP program.
3. Get the Development Class.
4. Execute Tcode SE84.
5. Open the Node 'Envir. -> Exit Techniques -> 'Customer Exits -> Enhancements'
6. Enter the Development class and execute.
Check out this thread..
The specified item was not found.
1. Type the transaction : system->status-> <PROG. NAME>
2 open SE37 , type EXIT<PROG NAME> and press F4 to get the list of function exits available.
3. Open CMOD utilities->SAP enhancements
EDIT->All selections
4.type the function module name obtained in step 2, in fields 'component name' in 'additional selections' block. and execute.
5. The displayed list contains the enhancements names for the transaction You were looking for.
6. Create a project in CMOD and the code in default include->activate.
http://www.erpgenie.com/sap/abap/code/abap26.htm
which gives the list of exits for a tcode
http://help.sap.com/saphelp_nw04/helpdata/en/bf/ec079f5db911d295ae0000e82de14a/frameset.htm
For information on Exits, check these links
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sapgenie.com/abap/code/abap26.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
http://www.easymarketplace.de/userexit.php
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sappoint.com/abap/userexit.pdfUser-Exit
http://www.planetsap.com/userexit_main_page.htm
User-Exits
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sap-img.com/ab038.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.sap-basis-abap.com/sapab013.htm
http://sap.ittoolbox.com/documents/popular-q-and-a/user-exits-for-the-transaction-code-migo-3283
These links will help you to learn more on user exits.
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://help.sap.com/saphelp_nw04/helpdata/en/c8/1975cc43b111d1896f0000e8322d00/frameset.htm
http://www.planetsap.com/userexit_main_page.htm
http://www.allsaplinks.com/user_exit.html
www.sap-img.com/abap/what-is-user-exits.htm
Also please check these threads for more details about user exits.
Re: Screen exit
user exit and customer exit
user exit
1. Document on UserExits in FI/CO
http://www.ficoexpertonline.com/downloads/User%20ExitsWPedit.doc
2. Finding User Exits...
http://sap.ionelburlacu.ro/abap/sap2/Other_Useful_Tips.html#Finding_User_Exits
3. List of all User Exits...
http://www.planetsap.com/userexit_main_page.htm -
Hi!
Can anyone please help me out with <b>screen exit</b> step by step. I will require that for Purchase Order screen.
Thanks and regards,
AtanuScreen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen -
how can we call a subscreen in screen exit.
how can we do error handling in bapi?differenece between bapi and bdc.
i will give the 10points to correct answers.
kiranHi,
Call subscreen in screen exit:
Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screens flow logic.
the tcode is cmod...
1.From the main screen of the Project management transaction, proceed as follows:
Select Enhancement components and choose Change.
2.Choose Edit component.
3.Choose the screen exit and double click on it
4.Create your subscreen using the Screen Painter.
5.Design your screen to be added to the standard screen and activate the particular screen and return back to the flow logic .
6.Choose the PAI and PBO to write down the logic.
7.Generate your screen and choose Back (the green arrow) to return to the Project management transaction.
8.Go to the transaction ME22 to view the customer defined screen exit.
9.Enter the purchase order number and press Enter.
10.Go to the menu header --> Details.
11.Purchase number is visible on the standard screen
Please check if the thread given below would be of any help.
http://sap.ittoolbox.com/groups/technical-functional/sap-r3-dev/menu-exits-72696#
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
error handling in bapi:
While creating BAPIs,include Return table (of structure BAPIRET2)as table parameter. This table is populated with error messages/Sucessful messages after BAPI was executed.
Diff b/w bdc and bapi:
BDC:
Batch Data Communication (BDC) is the process of transferring data from one SAP System to another SAP system
or from a non-SAP system to SAP System.
Features :
BDC is an automatic procedure.
This method is used to transfer large amount of data that is available in electronic medium.
BDC can be used primarily when installing the SAP system and when transferring data from a legacy system (external system).
BDC uses normal transaction codes to transfer data.
BAPI.
BAPI stands for Business API(Application Program Interface).
A BAPI is remotely enabled function module
ie it can be invoked from remote programs like standalone JAVA programs, web interface etc..
You can make your function module remotely enabled in attributes of Function module but
A BAPI are standard SAP function modules provided by SAP for remote access.
Also they are part of Businees Objest Repository(BOR).
Regards
Kiran Sure -
How can i add field to screen exit ?
ver 4.7
trans. me21n
add field in screen exit .
i implement screen exit MM06E005->SAPMM06E->0111
in the layout i try to add field by pressing
button in the toolbar ( dictionary field window ) ,
but when i press "save" in me21n ,
i get message "No data changed".
i choose in the dialog window
field from structure "ci_ekpodb" , field that i already
been add .
thanks .Hi
You have to implement the exit to import/export the data into/from screen-exit:
EXIT_SAPMM06E_016 and EXIT_SAPMM06E_018
Max -
Hi Experts:
I have done following Activities to add the subscreen in transaction LT04
1) Created SAP Enhancement project in CMOD
2) Used Enhancement: MWMRF104 to add the field in screen 104
3) Created Subscreen 9999 with program name "SAPLXLRF"
4) This screen in created under function module XLRF
5) Added TEXT field in Layout
6) Activated project
Project ZEZ0001F Ez Flow Screen Enhancement for LT04 TR to TO
Enh. Impl Exp MWMRF104 ENHANCEMENT FOR USER SCREENS (LOGSCR 0104 )
Function exit EXIT_SAPLLMOB_880
EXIT_SAPLLMOB_890
Screen exit SAPLLMOB 1104 EXIT0101 SAPLXLRF 9999
I am unable to see the text field in LT04 after activating the project.
Thanks
Ganesh.
Maybe you are looking for
-
Does NI DAQmx driver support PCI 6527 Card
In my application i am using PCI 6527 Isolated DIO Card. In the examples from LabVIEW 7.0, i refered the following VIs 1. Write Dig Chan.vi 2. Write Dig Port.vi using DAQ 7 Driver. There it gives a list of devices that can run these examples. The lis
-
Delete empty folder in bridge cc 6.0.1 on window 8.1 hang?
I use window 8.1 pro when I delete empty folder in adobe bridge cc 6.0.1x64 , the result is that adobe bridge program hang and it closed itself.It is bug of adobe bridge cc 6.0.1. Yes or Not
-
Status tool in the basis layer
Hello, We are in the process of developing a small tool in the Basis layer of ABAP. But in our tool we would need to do status management. Eg: the object would go from Ready->In process-> Active->Transport etc... baseed on different scenarios and sit
-
T400 dual monitors to standard display switch?
Hello... I have a T400 I bought in August 2009 running Windows XP. When I am home, I use my T400 in conjunction with a second dual display that acts as an extended desktop. I also like to take the laptop with me. The problem is that every time I retu
-
Hi My RG 1 register is missing..Any idea about this?? Thanks