Visa, BorladC++ Builder3.1, linking errors
I have linking error, then building my program written in BorlandC++ Builder3.1
(program has no compiling errors)
I need to use header in my program.
It was installed in C:\VXIpnp\Win95\include directory.
I have 2 linking errors:
Undefined symbol _viClose in module
Undefined symbol _viOpen in module
I copied all VISA (driver from National Insruments (www.ni.com), i use it to communicate with serial port RS232)
so I copied all VISA files from C:\VXIpnp\Win95 to C:\BorlandC dirctory ("include" ant "lib" folders respectively)
errors persist.
In BorlandC++ Options>>Directories i wrote paths to library and to include in C:\VXIpnp\Win95.
errors persist.
I also tried with following
3 programs:
1) BorlandC++ Builder 6 (evaluation version)
2) Icc – win32 (free) and
3) SoftIntegration Ch 4.5 standart (free)
They all throwed the same error messages:
Undefined symbol _viClose in module
Undefined symbol _viOpen in module
ViClose and viOpen are defined in hereby:
72) ViStatus _VI_FUNC viOpenDefaultRM (ViPsession vi);
83) ViStatus _VI_FUNC ViClose (ViObject vi);
I opened visatype.h to fined out how ViStatus....are defined and made table:
Are _VI_FUNC and VIPSession defined correctly?
(Because there is no such variable as ViPtr and VISAFN in BorlandC.)
If they are not how must i define them?
I attached visa.h and visatype.h and table for convenience.
Thanks in advise
Gintare
Attachments:
table.doc 34 KB
visatype.h 6 KB
visa.h 34 KB
Are you linking against C:\VXIpnp\Win95\lib\bc\visa32.lib? If not, do so and that should solve your problems.
If you are trying to link with that library, and it's not working, perhaps you'll need to create your own import library based on visa32.dll. We haven't changed the Borland import library in awhile, and I don't know if it's still compatible with the latest versions of the Borland products.
Dan Mondrik
National Instruments
Similar Messages
-
I wrote the following C command to pass SCPI commands to Rohde&Schwarz FSL
#define NIVISA_PXI
#include <visa.h>
#define MAX_CNT 200
int main(void)
ViStatus status; /* For checking errors */
ViSession defaultRM, instr; /* Communication channels */
ViUInt32 retCount; /* Return count from string I/O */
ViChar buffer[MAX_CNT]; /* Buffer for string I/O */
status = viOpenDefaultRM(&defaultRM);
if (status < VI_SUCCESS)
return -1;
status = viWrite(instr, "*RST", 6, &retCount);
status = viClose(instr);
status = viClose(defaultRM);
return 0;
I am getting linker errors. [Linker error] undefined reference to `viOpenDefaultRM@4'
I use Bloodshed Dev C++ . I have included the header files from the VXIPNP folder to the include folder od Dev C++. It had 11 files.it had 4 header files visa.h, visatype.h, vpptype.h and rsfsp.h
Do i need to install any header file or libraries? Please help, this is the first time I am using VISA.H
Solved!
Go to Solution.[root@localhost raavan]# gcc main.c -L /usr/local/lib/libvisa.so
/tmp/ccKHyQta.o: In function `sendscpi':
main.c: (.text+0x2e): undefined reference to `viWrite'
/tmp/ccKHyQta.o: In function `main':
main.c: (.text+0x52): undefined reference to `viOpenDefaultRM'
main.c: (.text+0x99): undefined reference to `viOpen'
main.c: (.text+0xbb): undefined reference to `viSetAttribute'
main.c: (.text+0xd9): undefined reference to `viClose'
main.c: (.text+0xeb): undefined reference to `viClose'
collect2: ld returned 1 exit status
contents of main.c are:
#include "visa.h"
#include "stdio.h"
#include "string.h"
#define MAX_CNT 200
char scpi[50]; /*To store the SCPI commands*/
ViStatus status; /* For checking errors */
ViSession defaultRM, instr; /* Communication channels */
ViUInt32 retCount; /* Return count from string I/O */
ViChar buffer[MAX_CNT]; /* Buffer for string I/O */
void sendscpi (char *s)
status = viWrite(instr, (ViBuf)s, strlen (s), &retCount);
int main(void)
/* Begin by initializing the system*/
status = viOpenDefaultRM(&defaultRM);
if (status < VI_SUCCESS) {
return -1;
/* Open communication with TCPIP Device at Primary Addr FSL (192.168.186.107)*/
status = viOpen(defaultRM, "192.168.186.107", VI_NULL, VI_NULL,&instr);
/* Set the timeout for message-based communication*/
status = viSetAttribute(instr, VI_ATTR_TMO_VALUE, 5000);
/* Send SCPI commands for the test case */
sendscpi ("*RST" ) ;
/* Close down the system */
status = viClose(instr);
status = viClose(defaultRM);
return 0;
Please help!
Message Edited by rohit_rs on 03-12-2009 07:04 AM
Message Edited by rohit_rs on 03-12-2009 07:04 AM -
I have some problem when I want to download app in iTunes some security question ask me about my visa when I right my visa number I got an errors and on top of the page told me go to iTunes support I do these things and now what should I do
Most of the people on these forums, including myself, are fellow users - you're not talking to iTunes Support here.
You can contact iTunes Support via this link : http://www.apple.com/support/itunes/contact/ - click on Contact iTunes Store Support on the right-hand side of the page, then Purchases, Billing & Redemption -
How do I fix a "Unsatisfied link error"?
ProQuest provides a Java application for auto parts. It did function on my system [10.3.9 with all updates]. After logging in on a web site, a "jnlp" file is loaded to the desktop. Double clicking this file causes another download to load the auto parts database.
But now a, JAVA error Exception reads:
java.lang.Unsatisfied Link Error: no hpwin32 in java.library.path
However a similar file "hpwin32.dll" is in: user/Library/caches/JavaWeb Start/cache/http/Depe.startekinfo.com /... /RN client-native.jar/hpwin32.dll
I deleted the "Depe.startekinfo.com " folder, but it reappeared after logging into their site.
Security is set to accept all cookies and using Safari and Firefox produces same result.
Suggestions are appreciated.
Bob
Quicksilver G4 w 2 HDs, LaCie 22 Mac OS X (10.3.9)The default VISA timeout is 2 seconds, so your program is missing a byte and timing out. You might want to log your serial port traffic to see the actual data coming through. Portmon is a fantastic tool for debugging serial applications: http://technet.microsoft.com/en-us/sysinternals/bb896644.aspx
Regards,
Jeremy_B
Applications Engineer
National Instruments -
Hi, I received an email with the link to download the new version of flash player for distribution, but does not work
Dear Miguel Ángel Abarca,
Thank you for submitting a request to distribute Adobe® Software. Your request has been approved, and you may now distribute the Adobe® Software listed below, subject to the terms and conditions set forth in the Adobe Reader and Runtime Software Distribution License Agreement.
Approved Software:
Adobe® Flash® Player
Adobe® Reader® Software
Attached is an Adobe Portable Document Format (PDF) file of the distribution license agreement. Please keep this file for your records. The agreement is valid for one year, after that one year you can renew the distribution license agreement by following the same process.
Below you will find the necessary details and download links for the product(s) that you have been approved.
Adobe® Flash® Player
To download the Flash Player version that you would like to distribute, please visit the following URL:
http://www.adobe.com/products/flashplayer/distribution4.html?auth=<number>Hello, here paste part of message:
To download the Flash Player version that you would like to distribute,
please visit the following URL:
http://www.adobe.com/products/flashplayer/distribution4.html?auth=4358bc39-5e77-4893-99cf- 9f7c7a8d5456
*You may not share the above link, share information with others, or
publish the above link on websites, blogs, or by any other means that
can be publicly accessed. The information contained on this site is
meant for your use only in accordance with Adobe Flash Player
Distribution License Agreement you accepted. You may direct others to
http://www.adobe.com/products/players/fpsh_distribution1.html to request
distribution rights.
El 13/01/2015 a las 17:53, m_vargas escribió:
>
Link error for distribution
created by m_vargas <https://forums.adobe.com/people/m_vargas> in
/Installing Flash Player/ - View the full discussion
<https://forums.adobe.com/message/7091835#7091835> -
Linker error during TestStand deployment
Using Version - LabVIEW 2014 and TestStand 2014
Test Stand deployment failed so I am trying to narrow down the issue.
Note:
1. Create Installer option is not selected
2. Everything has been mass compiled in LabVIEW 2014
Step 1 -
1. Selected Folder A which has around 70 LabVIEW controls
2. Build is successful
Step 2 -
1. Selected One single VI from Folder B
2. Build Successful
Step 3 -
1. Selected that same VI from Folder B and Selected Folder A (combining step 1 and 2)
2. Build Fail
"LabVIEW returned a linker error but did not return any missing VIs. This can mean that the missing files are RC files or other similar dependencies. Mass compile your top-level files and resolve the errors reported. If the problem persists contact National Instruments for support."
Other than "Enable SSE2 Optimization" none of the options are selected from LabVIEW VI Options.
Any idea?
Thanks,
VSThis may be useful:
http://digital.ni.com/public.nsf/allkb/19F78E0B290BFA63862574F8005A9303 -
after installing tuxedo, and compiled the simpapp application, started the service toupper as described. i faild with the simpcl.exe. it the ordinal number 14 is missing in the LIBFML.dll. could anyone please tell mit the propper link settings.
i am using msvc 6.0
thanks.
chris.Hello, here paste part of message:
To download the Flash Player version that you would like to distribute,
please visit the following URL:
http://www.adobe.com/products/flashplayer/distribution4.html?auth=4358bc39-5e77-4893-99cf- 9f7c7a8d5456
*You may not share the above link, share information with others, or
publish the above link on websites, blogs, or by any other means that
can be publicly accessed. The information contained on this site is
meant for your use only in accordance with Adobe Flash Player
Distribution License Agreement you accepted. You may direct others to
http://www.adobe.com/products/players/fpsh_distribution1.html to request
distribution rights.
El 13/01/2015 a las 17:53, m_vargas escribió:
>
Link error for distribution
created by m_vargas <https://forums.adobe.com/people/m_vargas> in
/Installing Flash Player/ - View the full discussion
<https://forums.adobe.com/message/7091835#7091835> -
Installation of 11i on 32-Bits OEL4 having linking error.
Hi,
I am trying to install 11i (11.5.10.2) on OLE 4.x 32-Bits, but having linking errors when adlnkoh.sh running. The log show following error message cat 10120907.log".
adlnkoh.sh started at Fri Oct 12 09:21:06 EDT 2012
logfile located in /ebs11i/oracle/visdb/9.2.0/install/make.log
Error while running adlnkoh.sh. Please check logfile
Errors while running adlnkoh.sh
There was an error while running the command - /ebs11i/oracle/visdb/9.2.0/temp/VIS_ebs11i40/adrun9i.sh APPS APPS
/ebs11i/oracle/visdb/9.2.0/appsutil/install/adlnkoh.sh: line 207: /ebs11i/oracle/visdb/9.2.0/bin/sqlplus: No such file or directory
RW-50010: Error: - script has returned an error: 1
RW-50004: Error code received when running external process. Check log file for details.
Running Database Install Driver for VIS instance
Now the make log /ebs11i/oracle/visdb/9.2.0/install/make.log is showing following messages:
running genclntsh...
/ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o: file not recognized: File format not recognized
collect2: ld returned 1 exit status
genclntsh: Failed to link libclntsh.so.10.1
rm -f oracle dbv tstshm maxmem orapwd dbfsize cursize genoci extproc extproc32 hsalloci hsots hsdepxa dgmgrl dumpsga mapsga osh sbttest expdp impdp imp exp sqlldr rman nid extjob extjobo genezi ikfod grdcscan /ebs11i/oracle/visdb/9.2.0/rdbms/lib/ksms.s /ebs11i/oracle/visdb/9.2.0/rdbms/lib/ksms.o
But when I check details about file kpudfo.o, it is showing 64-Bits, How come this file is 64-Bits when I am installing 32-Bits application?
[oracle@ebs11i40:/ebs11i]$ file /ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o
/ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o: ELF 64-bit LSB relocatable, AMD x86-64, version 1 (SYSV), not stripped
Please help me with this issue.
Thanks.There was an error while running the command - /ebs11i/oracle/visdb/9.2.0/temp/VIS_ebs11i40/adrun9i.sh APPS APPS
/ebs11i/oracle/visdb/9.2.0/appsutil/install/adlnkoh.sh: line 207: /ebs11i/oracle/visdb/9.2.0/bin/sqlplus: No such file or directory
RW-50010: Error: - script has returned an error: 1
RW-50004: Error code received when running external process. Check log file for details.
Running Database Install Driver for VIS instanceWhat version of gcc have you installed? Please make sure you are using the correct version (Perl Adcfgclone.pl dbTechStack Failed While Relink /usr/lib/gcc/i386-redhat-linux/3.4.6/libgcc_s.so: undefined reference to`dl_iterate_phdr@GLIBC_2.2.4' [ID 417605.1]).
/ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o: file not recognized: File format not recognized
collect2: ld returned 1 exit status
genclntsh: Failed to link libclntsh.so.10.1
rm -f oracle dbv tstshm maxmem orapwd dbfsize cursize genoci extproc extproc32 hsalloci hsots hsdepxa dgmgrl dumpsga mapsga osh sbttest expdp impdp imp exp sqlldr rman nid extjob extjobo genezi ikfod grdcscan /ebs11i/oracle/visdb/9.2.0/rdbms/lib/ksms.s /ebs11i/oracle/visdb/9.2.0/rdbms/lib/ksms.o
But when I check details about file kpudfo.o, it is showing 64-Bits, How come this file is 64-Bits when I am installing 32-Bits application?
[oracle@ebs11i40:/ebs11i]$ file /ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o
/ebs11i/oracle/visdb/9.2.0/rdbms/lib/kpudfo.o: ELF 64-bit LSB relocatable, AMD x86-64, version 1 (SYSV), not stripped
Please help me with this issue.What is the output of "uname -m" command? -- Installing onto Linux And Receive error: Genclntsh: Failed To Link Libclntsh.So.10.1 [ID 340861.1]
Thanks,
Hussein -
Linker Error during compiling ODBC WinCE C++_Sample Project
I am devloping a ODBC application for PocketPC2003 using OLite 10g Release 10.3.0.2. before that i am understanding the sample application provided with Olite.
I followed all the instructions provided in ReadMe.txt file available before using VC++ sample. After making all the settings and compiling i am getting following linker errors as mentioned below.
Any solution for this problem at the earliest will be appreciated, i have tried link all the libraries provided with WinCE armv4.
Linker Error Messages:
Error 1 error LNK2019: unresolved external symbol SQLExecDirect referenced in function "public: virtual __cdecl CSQLResult::~CSQLResult(void)" (??1CSQLResult@@UAA@XZ) dbaccess.obj
Error 2 error LNK2019: unresolved external symbol SQLFreeStmt referenced in function "public: virtual __cdecl CSQLResult::~CSQLResult(void)" (??1CSQLResult@@UAA@XZ) dbaccess.obj
Error 3 error LNK2019: unresolved external symbol SQLGetData referenced in function "public: class CRowObj const * __cdecl CSQLResult::Fetch(int)" (?Fetch@CSQLResult@@QAAPBVCRowObj@@H@Z) dbaccess.obj
Error 4 error LNK2019: unresolved external symbol SQLFetch referenced in function "public: class CRowObj const * __cdecl CSQLResult::Fetch(int)" (?Fetch@CSQLResult@@QAAPBVCRowObj@@H@Z) dbaccess.obj
Error 5 error LNK2019: unresolved external symbol SQLFreeEnv referenced in function "public: void __cdecl COLiteDB::Disconnect(void)" (?Disconnect@COLiteDB@@QAAXXZ) dbaccess.obj
Error 6 error LNK2019: unresolved external symbol SQLFreeConnect referenced in function "public: void __cdecl COLiteDB::Disconnect(void)" (?Disconnect@COLiteDB@@QAAXXZ) dbaccess.obj
Error 7 error LNK2019: unresolved external symbol SQLDisconnect referenced in function "public: void __cdecl COLiteDB::Disconnect(void)" (?Disconnect@COLiteDB@@QAAXXZ) dbaccess.obj
Error 8 error LNK2019: unresolved external symbol SQLConnect referenced in function "public: int __cdecl COLiteDB::Connect(void)" (?Connect@COLiteDB@@QAAHXZ) dbaccess.obj
Error 9 error LNK2019: unresolved external symbol SQLAllocConnect referenced in function "public: int __cdecl COLiteDB::Connect(void)" (?Connect@COLiteDB@@QAAHXZ) dbaccess.obj
Error 10 error LNK2019: unresolved external symbol SQLAllocEnv referenced in function "public: int __cdecl COLiteDB::Connect(void)" (?Connect@COLiteDB@@QAAHXZ) dbaccess.obj
Error 11 error LNK2019: unresolved external symbol SQLError referenced in function "public: class CSQLResult * __cdecl COLiteDB::Execute(wchar_t const *)" (?Execute@COLiteDB@@QAAPAVCSQLResult@@PB_W@Z) dbaccess.obj
Error 12 error LNK2019: unresolved external symbol SQLDescribeCol referenced in function "public: class CSQLResult * __cdecl COLiteDB::Execute(wchar_t const *)" (?Execute@COLiteDB@@QAAPAVCSQLResult@@PB_W@Z) dbaccess.obj
Error 13 error LNK2019: unresolved external symbol SQLNumResultCols referenced in function "public: class CSQLResult * __cdecl COLiteDB::Execute(wchar_t const *)" (?Execute@COLiteDB@@QAAPAVCSQLResult@@PB_W@Z) dbaccess.obj
Error 14 error LNK2019: unresolved external symbol SQLAllocStmt referenced in function "public: class CSQLResult * __cdecl COLiteDB::Execute(wchar_t const *)" (?Execute@COLiteDB@@QAAPAVCSQLResult@@PB_W@Z) dbaccess.objHi,
The OLITE forum (Database Mobile Server (inc. legacy Database Lite) would be a better place to post your issue. This forum deals with the ODBC driver that connects to a "normal" Oracle database.
Hope it helps,
Greg
Edited by: gdarling on Nov 12, 2008 8:31 AM -
Hi,
Please help me with this broken link error in Office Excel 2010. Thank you.
The problem is: a broken link cannot be removed from the file. The link was used in data validation, which refers to a list of values. After the path was corrected, it still shows there’s a broken link. Here are the details:
I have 4 files named “000TVA_Test – 3”, “000TVA_Test – 4”, “000TVA_Test – 5”, and “000TVA_Test – 6”. The posterior files were developed based on the previous files.
In Test-3, sheet “Template “, cell “L4”, “O4”, “R4”… were built as dropdown list using data validation. The list source is in the “Library” worksheet. There’s no problem so far.
Test-4 was firstly copied from Test-3. In this file I renamed the worksheet from “Library” to “Setting” and the link was broken from here. I can also fix the broken link in this file. (While I didn’t realize there was a broken link.)
In Test-5 I fixed the path, but every time when opening the file, the broken link still shows.
In Test-6 I’ve removed the data validations. The broken link is still there.
I tried to find solutions online. I tried common methods, cannot find anything in the files is still using links. I also tried the “findlink.xla” add-in, but it only worked for Test-4, and couldn’t find the link in other files.
Please help. Thank you!
I uploaded files here: https://onedrive.live.com/redir?resid=1A97736E0ABBAA41!113&authkey=!AF5wAd9rwUPnYyE&ithint=folder%2cxlsm
Thanks again!Hi,
Based on my tested the files downloaded, I found that Test-5 & Test-6 included the "A defined name that refers to an external workbook", Test-4 had not. (Please click Formula Tab>Name Manage, you'll see them.)
However, the Break Links command cannot break the following types of links:
A defined name that refers to an external workbook
A ListBox control with an input range that refers to an external workbook.
A DropDown control with an input range that refers to an external workbook.
http://support2.microsoft.com/kb/291984/en-us (It also applies to Excel 2010)
Thus, we'd better try the workaround: re-build the Test-5 & Test 6.
Regards,
George Zhao
TechNet Community Support
It's recommended to download and install
Configuration Analyzer Tool (OffCAT), which is developed by Microsoft Support teams. Once the tool is installed, you can run it at any time to scan for hundreds of known issues in Office
programs. -
I am writng a simple application in C language for communicating with GPIB. when I compile the c file I am getting a linker error
LIBC.lib(ctr0.obj): LNK2001 error: unresolved sysmbol _main
I compile the application in the dos window using the command
cl gpibApplication.c gpib-32.obj.
Could anyone tell me how to remove this errorHello-
It sounds like the main function is missing from the gpibApplication.c file. Be sure that the following function is somewhere in the code:
int main (int argc, char *argv[])
Also, note that this function is case sensitive, so be sure main is not capitalized.
Randy Solomonson
Application Engineer
National Instruments -
Link errors on HP Itanium and Oracle 9.0.1.0.1 Developers Release
We have pulled down the Oracle Developers release for HP-UX 11.22 and were not able to compile the Oracle code
because of a link error. We are getting the following errors in the make.log file:
(Bundled) cc: error 1913: `16M' does not exist or cannot be read
(Bundled) cc: error 1913: `L' does not exist or cannot be read
(Bundled) cc: error 1913: `1M' does not exist or cannot be read
(Bundled) cc: error 1913: `1M' does not exist or cannot be read
*** Error exit code 1
Stop.
Has anyone run into this issue and how was it resolved?
Thanks,
WalterAlex,
does a
select xmlelement("SQLX", 'Hello ,World!') from dual; work?
SQL> select xmlelement("SQLX", 'Hello World!') from dual;
XMLELEMENT("SQLX",'HELLOWORLD!')
<SQLX>Hello World!</SQLX>
It works for me in 9.2
SQL> select xmlelement("orderid", order_num) from orders;
XMLELEMENT("ORDERID",ORDER_NUM)
<orderid>1</orderid>
<orderid>2</orderid>
<orderid>3</orderid>
<orderid>1</orderid>
<orderid>2</orderid>
<orderid>3</orderid>
6 rows selected.
SQL> -
The forums have suggestions on this topic but I don't understand the lingo used.
Remember card catalogs in libraries? The computer has its own card catalog that tells it where all the files are. That's known as the directory.
Sibling link error indicates something is wrong with one of the cards, making the computer lost. Now the computer will put forth a bunch of gobbledy gook to fix this error, but you can do it.
Since the issue is with the external hard disk, you must select it with Disk Utility's First Aid selected. There you will repair the disk. If it can't repair the disk, you will need to use a more powerful tool. The question is, is your data backed up elsewhere, or is it not? If it is not, the same symptoms of a bad directory can also implicate a dying hard drive. You'll want a data recovery tool if you aren't backed up. If you are backed up, and there is nothing that can't be replaced on that external hard drive, get Alsoft Disk Warrior. This should fix most bad sibling link errors repair disk can't. When it can't, you can give up on the external hard disk.
P.S. Permissions has NOTHING to do with the directory. Do not worry about issues with permissions or attempting to repair it at this stage. -
"Not an executable or is a link" errors when starting Messaging Server
"Not an executable or is a link" errors when starting Messaging Server
<P>
If Calendar Server 3.x has been installed to the same server root
as Messaging server, it is possible that the command 'NscpMail start'
to restart the server will return a string of errors:
# /etc/NscpMail start
19971207145610:Dispatch:Notification:Local Module
(Account-Handler) is not a n executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Account-Manager) is not a n executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(AutoReply-Handler) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Configuration-Manager) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Error-Handler) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Mailbox-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Program-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(SMTP-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(SMTP-Router) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(UNIX-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(Finger-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(IMAP4-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(POP3-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(SMTP-Accept) is not an executable or is a link.
Module not loaded.
Startup Problem:
Module Error-Handler is required for proper operation.
Netscape Messaging Server Exiting!
The Calendar server 3.x installation may have changed the permissions
on [server-root]/bin directory from 755 to 750. Simply issue the
command (as root) 'chmod 755 [server-root]/bin' and then start
the server with the 'NscpMail start' command, and it should start
without a problem."Not an executable or is a link" errors when starting Messaging Server
<P>
If Calendar Server 3.x has been installed to the same server root
as Messaging server, it is possible that the command 'NscpMail start'
to restart the server will return a string of errors:
# /etc/NscpMail start
19971207145610:Dispatch:Notification:Local Module
(Account-Handler) is not a n executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Account-Manager) is not a n executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(AutoReply-Handler) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Configuration-Manager) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Error-Handler) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Mailbox-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(Program-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(SMTP-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(SMTP-Router) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Local Module
(UNIX-Deliver) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(Finger-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(IMAP4-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(POP3-Server) is not an executable or is a link.
Module not loaded.
19971207145610:Dispatch:Notification:Network Module
(SMTP-Accept) is not an executable or is a link.
Module not loaded.
Startup Problem:
Module Error-Handler is required for proper operation.
Netscape Messaging Server Exiting!
The Calendar server 3.x installation may have changed the permissions
on [server-root]/bin directory from 755 to 750. Simply issue the
command (as root) 'chmod 755 [server-root]/bin' and then start
the server with the 'NscpMail start' command, and it should start
without a problem. -
I have a 15" PB which gave an "invalid sibling link error" one month ago and I was not able to even repair it using DiskWarrior. I have Apple Care Protection plan, so I sent it for repairs and the repair guys replaced the motherboard as they suspected it was the reason. On return, I reformatted the HD and installed everything from stratch. Everything was working fine till last Saturday morning, when computer would not boot up. So I checked using Disk Utility from PB DVD, and the dreaded "invalid sibling error" came up again. Since I have a bootable backup of the HD, I formatted the HD and tried to load the system on the HD from the backup copy. But the writing of backup using CCC hung up and I had to quit it. After that I was not able to find the HD using Disk Utility from DVD.
I have sent it for repairs again, but can anyone help me understand the core problem here. Since last time they replaced the motherboard, I think they will replace the HD this time around. Is the logic board, motherboard or the HD that is the root cause of the problem?
Powerbook G4 Mac OS X (10.4.7) 100GB HDD, 1.5GB RAMI had never heard of "invalid sibling link error" until you post, and when I ran a search on it the best explanation I could find is that it is a directory-related problem. See the following (assuming it is correct): http://www.computing.net/mac/wwwboard/forum/2584.html The suggestion there, though, is that DIsk Warrior should be able to fix the problem, and you've already told us that you tried using Disk Warrior on it and it did not work.
Very puzzling. Please post back what happens when you get your PB back from being repaired.
Good luck.
-- JDee
Maybe you are looking for
-
IPhone, Google & iCloud contact syncing issues
Hi everyone, I'm having some issues getting my contacts synced correctly between my iPhone and Google account. I have searched a few forums looking for an answer for this particular problem and haven't found a solution yet so my apologies if I'm just
-
Cannot access web page anymore
I can no longer access my banks web page anymore. I was able to get to the page and sign in up to a few days ago. When I try to get to the page I get a message that says "Safari can't open the page "https://www.essabank.com/index.cfm?" because the s
-
WSUS 2012r2 Implementation in an Enterprise Environment
We are going to install and configure WSUS with server 2012r2 but have questions on best practices for installing it in a good size enterprise network. First, should I use the Windows Internal Database or download SQL Express for use with the WSUS s
-
I've problems exporting in quick time : green line and got a video that doesn't go smooth
every time i try to do export with quick time i got problems : green line video that that stops every now and then is it a problem of the machine or of the video for last i tried to share media and i got a video that go smothly but when i burned the
-
Seeking a clear answer...
Hi, I have a new Extreme (n) base station, but am running on a 12' PB G4. I have my external HD set up and am able to access it wirelessly. My problem is, I want to watch the movies I have on my hard drive, and it seems the data transfer is too slow