Vision Run-Time Evaluation Period

HI NI,
I have an application that uses NI Vision functions which require a Vision Run-Time license.  When I distribute this application to potential customers they should be able to run the application with the Vision Run-Time license in "evaluation mode" for 30 days, or at least that used to be the case.  Now, when my potential customers install and run the application they get an error message "Error -1074396157 occurred at an unidentified location Possible reason(s): IMAQ Vision:  Unlicensed copy of NI Vision."
Why will it not allow me to run in evaluation mode?
Thanks,
B

Hi Ian,
My customer sells software built on LabVIEW and the Vision Development module.  His potential customers often want to "evaluate" the software before purchasing it.  So, the evaluation period for the vision run-time license is very important.  I wonder if the licensing department has considered this scenario.  Not having an evaluation period for the vision run-time license will make it more difficult for him to sell his software which may trickle down to impact National Instruments sales as well.  I would appreciate it if you would communicate this back to the licensing department.
Here is my customers response to the new policy:
This is an Interesting justification for NI's decision....albeit misplaced.
If the development includes the Vision run time then how on earth is one
to evaluate the development ? If the development requires the Vision
run time license to execute how can that be perceived, by any rational
person, to supersede ( definition: Supersede: take the place of; supplant)
the Vision run time license ? It doesn't supersede it. it complements it.
Thanks for your consideration,
B

Similar Messages

  • Problem: Run Time Evaluation for Future Period

    Hi SAP Gurus, can someone help me solving this problem:
    My client need to run time evaluation for 2-months period ahead of time. But every time I tried, time evaluation always stops at end of the current month, no further dates in the future. I had created attendance data 2002 for all the future dates. IT7, 2002, 2006 and all configurations seem to be OK (T510S,T569R). Test run is also OK with good future results. What could possibly be missing? Thank you in advance.
    Bill

    Thank you very much, Arun, Banu, Stefan and Om.
    Yes, I have entered the "Evaluation up to" date (60 days later);
    The schema has a function "Check FUT".
    Test future run result was generated correctly.
    Still I can't have future results in real run.
    So, what else I should check into?
    Thanks again.
    Bill

  • Programatically determine if Vision Run-Time Engine Activated

    I am working with an application that requires the Vision Run-Time Engine.  After installation, if the Vision Run-Time Engine is not activated I get a pop-up (Vision Evaluation notice) that is behind my main application window.  The pop-up is launched when I am running an analysis with the application (I assume the pop-up is invoked when I am calling a Vision Development VI).  It appears to the user as if the application hangs.  I can force the pop-up to be frontmost so the user will see the window.  However, I'd like to be able to programatically determine if the Vision Run-Time Engine has been activated.  This way I will not have to continue to poll for this window after it has been activated.  Is there a way to do this?
    Also, suggest that this pop-up window should be made front most so this work around isn't necessary.  Please take a look into this NI R&D.
    Thanks!
    Brooks

    Hi Brooks, 
    You should be able to probe the error wire and look at the error message to see if the RTE is activated or not. This is the standard way of programatically checking to see if a license exists. 
    -N
    National Instruments
    Applications Engineer

  • How to install Vision run-time engine to a desktop PC converted to real-time target

    Hi, all
    I don't know how can I install the vision run-time engine to a desktop PC which I converted to a real-time target.  The same problem applies to installing real-time run-time engine and labview run-time engine to the real-time target.  The only way to install software to real-time target is through "add/remove software" in MAX for remote system, but it is not for all types of run-time engine installation.  
    I am also confused about how to activate those run-time engines for the desktop PC as real-time target.
    Please help and great thanks.
    Wei 

    Hi turtle,
    Here is a link that explains how to set up a desktop PC as a real-time target.  The section for Formatting & Setup should help you the most.
    NI Developer Zone Tutorial: Requirements for Desktop PCs as LabVIEW Real-Time Targets
    Justin D.
    Applications Engineer
    National Instruments

  • Clock In Clock Out Report without running Time Evaluation

    Hi Every1
    Is it possible to get report on clock in clock out without running time evaluation?? Can we get a report on Time events after uploading Punch in punch out from other system thru BDC?
    Here requirement is as soon as punch in punch out is uploaded on daily basis thru BDC they shud get a report on Clock In from th system so that they can immediately find out in morning shift how many employees are present.
    Thanks & Regards
    Neha

    Well what tables are you uploading in the BDC ?? are the PTX tables being uploaded or the PA2011 Tables uploaded ?
    If the PA2011 Tables are uploaded then yes we can run a report for each day as required but if the PTX tables are updated then they are either waiting for managers approval or to be transfered to HR which triggers updation of the Infotypes accordingly.
    And when you transfer to HR i guess Infotype 2011 is not updated but rather 2001 and 2002 Tables are updated but have to check on this, time eval schema would not update 2011 Infotype but rather would update ZL tables with time types if present, try to figure out what table the BDC updates each night.
    Edited by: insane saint on Jul 14, 2009 10:38 PM

  • Does Vision Development Module obviate the need for the Vision Run Time Engine?

    I have several computers with the full version of Labview (8.0.1 and\or 8.2) as well as the most recent version of the Vision Development Module (VDM 8.2.1), all fully registered and activated.  In addition, I have one computer we have designated the "build" computer which has the professional version of LV 8.2 as well as LV 8.0.1 Full version w/ Application Builder (we have delayed migrating certain applications to 8.2 for various reasons).  Instead of distributing applications as source distributions to these computers (uncompiled VIs), we would like to use our build computer to compile applications that make use of the Vision image processing VIs.  I know that all of these computers have the appropriate LV run time engines installed, but I was wondering if I need to install (and thus purchase) the Vision Run Time Engine for each of these computers.  I know that when you install VDM, you also get a copy of the vision RTE (in C:\Program Files\National Instruments\Vision\Run-Time Engine).  Does this mean the engine is already installed and ready to run compiled applications?  Or do we need to pay for the engine on each computer?

    The Development module includes the RTE for that machine.
    For the other machines, you will need to purchase the Vision RTE and install and activate for each machine. See the KB article below for more details.
    http://digital.ni.com/public.nsf/websearch/F1699570F78FECBB86256B5200665134?OpenDocument
    Ed
    Ed Dickens - Certified LabVIEW Architect - DISTek Integration, Inc. - NI Certified Alliance Partner
    Using the Abort button to stop your VI is like using a tree to stop your car. It works, but there may be consequences.

  • NI Vision Run-Time Engine 8.2 - Error user is now getting when attempting install of built software

    I've built an installer for an application using LabVIEW 8.2 and Vision8.2.  I have sent this installer to someone for 6 months and they have had no problems completing the install. 
    Now the last time that I sent the installer, the user is getting the attached error during install.
    "NI Vision Run-Time Engine 8.2
    Error: Another installer or uninstaller is running.
    Finish that installer or uninstaller and try again."
    When the user clicks OK to this error, the user is then told to restart or finish uninstall.  Since we do not know what uninstall is being asked for, the user restarted the computer and attempted running the software - to which he was prompted for LVWA.dll file and he did not know what to do from there.
    I gave the installer to a second beta-tester - the same thing occurred.
    The only thing 'of significance' that has changed in my software that I can think of that is Vision related is the inclusion in the software of the ability to read/write .TIF files.  I have no clue whether that might have anything to do with the error.
    Any help is appreciated.  NI - I can post the installer ZIP to your ftp site if you want.
    Sincerely,
    Don
    Attachments:
    error.jpg ‏30 KB

    Hello Don,
    Have you tried uninstalling the previous Vision run-time
    engine on the deployed computer before running the new installer?   You
    might also want to try running the Vision RTE separately from the installer to
    see if you are able to manually run it on the target.  Here is a document which explains the
    procedure for both manually installing the RTE as well as how to include it in
    the LabVIEW installer:How do I
    Deploy LabVIEW 8.0 and 8.20 Applications with NI Vision 8.0 and 8.2?
      I also found
    a Knowledge Base that may be helpful addressing the error you mention in your
    first post.  I hope this helps.
    How Do I
    Correct the "Another Installer Is Already Running" Error Message?
    Regards,
    Vu D

  • No entry in table T001P for key when running time evaluation

    Hi There,
    All the master data is in synch and I am getting this error when
    running time evaluation.
    *No entry in table T001P for key
    Person rejected: xxxxxxxx*
    Apparantly this seems to be config error but we have lot of EEs like this, working okay. All the  master data dates are correct.
    Any comment/help is greatly appreciated.
    Thanks,
    Gajanan

    Hi,
    In one of the thread i have read that, after maintaining Contract Type the issue has been resolved.
    and in other thread he says
    "the issue is caused by a mismatch in the employee's master data dates. Particularly with infotype 8, the first record of his basic pay had a date prior to his hire date"
    Can you please check it once.
    Good Luck..!
    KK

  • Licence NI VISION Run-Time Engine

    Bonjour,
    Je vous envoie cette question parce que malgré le nombre de doc que j'ai pu trouver en relation avec ma question, je n'ai pas eu de réponse clair à mon pb :
    Je possède une application qui a été développé avec LV 8.2.1 faisant appel à des fonctions issues de NI IMAQ 3.7. (Très brièvement le programme acquiert des images provenant d'une caméra, réalise des opérations simples sur les images et enregistre les resultats de ces opérations, donc d'autres images).
    J'aimerai savoir quels sont les licences que je dois acheter pour installer la version compilée de mon prog sur pc client (qui ne possède pas LV). (Je sais deja que je devrai acheter pour chaque PC client une licence IMAQ 3.7 mais concernant le traitement de ces images puis-je me contenter de NI VISION Run-Time Engine 8.2.1 qui me semble-t-il est gratuit de la même façon que NI LABVIEW Run Time Engine 8.2.1)
    Merci d'avance pour vos réponse qui je l'espère m'aideront à voir plus clair entre les IMAQ vision, vision run-time, VISA Run-time....
    Solved!
    Go to Solution.

    Bonjour fabrice91,
    Le NI-VISION Runtime est disponible au téléchargement et ce
    gratuitement, cependant lors de  l'installation
    il te faudra l'activer. Lorsque tu crée un exécutable LabVIEW n'intègre pas
    automatiquement de Run Time Engine, c'est pourquoi il te faut créer un
    installeur qui contiendra le RTE de LabVIEW et de NI-VISION. Si tu lance l'exécutable
    sur le poste de développement il est normal que ton application tourne car tu
    as tous les Runtime nécessaires sur ce poste. Par contre si tu essaye de lancer
    ton application sur une machine où il n'y a aucun logiciel NI ton exécutable ne
    devrai pas fonctionner et c'est là que vient ton installeur. Pour connaitre les
    programmes National Instruments installés sur un PC tu as plusieurs
    possibilités soit de passer par Measurement & Automation Explorer soit
    Démarrer >> Panneau de Configuration >> Ajouter/Supprimer des Programmes
    >> Logiciels National Instruments.  
    Benjamin R.
    R&D Software Development Manager
    http://www.fluigent.com/

  • Error when running time evaluation

    Hi,
    When I am running time evaluation I got this error "start of pair formation changed from 20040101 to 20081212"
    I am using TM01 schema. Please help me out with this error.
    Thank you
    Shravan

    Hi Shravan,
    Please check infotype 0007 if the work schedule has changed fron 01/01/2004.
    Also please check the generated workschedule used for that employee , if the config has changed and that work schedule has been re- generated with a different DWS.
    Thanks.

  • Unable to run time evaluation for the entire year...

    hi experts,
    I'am unable to run time evaluation for the entire year, even though mentioned the date as Force calculation as of : 01.01.2010
    and evaluation upto date : 31.12.2010.  when time evaluation is run , the log is only run for Jan 2010.
    Maintained IT2011 from 01.01.2010 to 31.12.2010
                      IT0050 from 01.01.2010 to 31.12.9999
                      IT0003 : PDC recalculation : 01.01.2010
    Kindly advise.
    Regards
    Pammi

    Check if Time Management status is 1 or 9....
    If it is 1 then it would not run for the entire year..It would run only till today. If it is 9, then the TE runs for future also...also check if in the schema it is activated for future runs or not...

  • Quota generation issue while running time evaluation

    Dear Experts,
    we are using positive time management ,generally we will generate quota based on number of working days of the employee ,so for counting working days we will add day off and public holidays also ,now quota is generating fine ,but if the employees applies leave in between week off ,then quota is using for the week off also but that day is adding to the working days so quota is generating for that day as well ,please give me some inputs how to exclude that day .it is very urgent,please help me experts .
    if employee taken leave from 1st to 15th
    calender days -15 days
    absence days - 13 days
    Quota Used  -15 days
    in this case the absence days should be 15 days

    When you mention Absence Days as 13, this is what you see in 2001 screen. You cannot change this as SAP calculates the absence days as those which are working days.
    When it comes to your PCR where you are counting WOFF and PH to generate quota you will need to query the absence type and include/exclude the leave types based on your business logic. If you can share the PCR which is used for generating quota, maybe it will give us a clue.
    Regards
    Pramod

  • Time Evaluation Re Run in Mid Month & Mid Mont Initialization !

    Hi There,
    i was trying to run Time evaluation for the period 01.04.2011 to 31/12/2011.
    from April, that is 01.04.4011 to 30.06.2011 Time evaluation was good, now time evaluation has to run from 01.07.2011 but time evaluation has repeated from 12.06.2011 to 11.07.2011 as Initialization period 07/2011, and the same scenario is repeated for the rest of the year..all periods are initiated on 12th of each month from 6th month that is 12.06.2011.
    i was been trying to rectify this issue but was not bale to solve it, could any one please look in to it and let me know how to solve it?
    your help is appreciated.
    Thanks
    Kumar

    Can you please regenerate Period Parameters for 2011 year in T-Code for OG00 for period parameter 01 and then give the hire date in the field Forced Recalculation as of run in PT60 and run  the time evaluation.
    Best Regards,

  • Time Evaluation Re Run

    Hi There,
    i was trying to run Time evaluation for the period 01.04.2011 to 31/12/2011.
    from April, that is 01.04.4011 to 30.06.2011 Time evaluation was good, now time evaluation has to run from 01.07.2011 but time evaluation has repeated from 12.06.2011 to 11.07.2011 as Initialization period 07/2011, and the same scenario is repeated for the rest of the year..all periods are initiated on 12th of each month from 6th month that is 12.06.2011.
    i was been trying to rectify this issue but was not bale to solve it, could any one please look in to it and let me know how to solve it?
    your help is appreciated.
    Thanks
    Kumar

    Hi,
    thanks for reply but till now i have not yet customized the schema or any pcr, so it is pretty much standard TM04 schema, could  you plz elaborate your answer?
    Thanks.
    Kumar

  • How to prevent Time Evaluation to run for past date?

    Dear Friends,
    I have a problem with Time evaluation issue.
    While time evaluation runs with PDC recalculation date in 2010 its creating two different quota for an absence.
    So client donu2019t want to run time evaluation for before 31.12.2010.
    Please let me know how to do this.
    They donu2019t want to used earliest recalculation date filed for this purposes.
    Thanks and in advance,
    Anoop

    Hi,
    They want to use Earliest personal recalculation date for monthy locking.

Maybe you are looking for

  • Lock/unlock and charging sound.

    Yesterday night at 12:35am my lumia 535 phone lock/ unlock and charging sound was not work. So can. I or you please resolve this issue.

  • Purchase order for project

    Hello together, We have a one senerio. At my client end no. of project is going on. We do not have sales order for the project parts. Presently we are creating purchase order with acct.assignment P ( WBS Element ) but our mamangement asking me to hav

  • 3rd Gen Ipod Will Not Charge on Wall Charger

    I have a 3rd Generation non- click-wheel Ipod. Stock Cords Never opened up Dock No way of charging it on my computer (usb 1.1 and 4 pin firewire) I recently bought a wall charger, and I plug it in, and nothing happens. I am really anxious to use my i

  • How do I search the internet on a new macbook pro

    How do I get the google app to search the internet?  I cant find it in the app store.

  • Problem with storage Bin

    Dear All, My request is like in material master i have assigned Storage bin ( WH2 view ) but at the time of creating Transfer Order if user put different storage bin then system accept that at post the material to other storage bin .... ( not puting