VMware ESX and dual homing
We are beginning to deploy VMware ESX servers for Windows production environments. How do I set up the VNICs to dual home the VM's to separate Catalyst 6500's.
Thanks, Lisa
Hi Steve,
Specific to VSS by itself, that is available and shipping today, but support for the FWSM with VSS is not yet available (as you have already noted :-). I am currently hearing Q3CY08 as a possible timeframe for supporting VSS and the FWSM, but that is not written in stone. In the mean time, you could still take advantage of VSS to do the multi-chassis EtherChannel, just not with the FWSM included.
Specific to the question on the quad mezz cards, I personally do not have any experience with this specific card, but do know that teaming/bonding software is getting better every day, but we all know that not everything works as advertised, so in that case (and actually, in every case if you think about it), any such design should be fully tested before going into production, to make sure it works as expected/desired.
In your post you mention the 3020 (HP Cisco blade switch). That does indeed throw a bit of a wrench in the works, since as you noted, the NICs will each go to separate physical switches in the enclosure, thus making EtherChannel type solutions on the server impossible. In that case, I normally recommend a simple Active/Standby form of teaming/bonding, as it is robust and deterministic (proprietary forms of Active/Active, in my experience, are neither). If you did decide to go with pass-thru (instead of 3020) to a VSS environment, you could then take advantage of the EtherChannel type teaming, but then you introduce the headache of all of those cables from the pass-thru's, which defeats one of the more common purposes many people go to blades, reduced cabling.
Another solution that would give you the best of both worlds in a blade enclosure (reduced cabling and EtherChannel teaming on the servers), is to look at the new 3120's just coming out. With their stacking ability, multiple switches look and act as a single logical switch (exactly like the 3750E), so when these are deployed in the enclosure and stacked, you can indeed use EtherChannel on the server NICs while still getting cable reduction for the enclosure.
HTH, Matt
Similar Messages
-
IronPort ESA - HA and Dual Homing
Hello, i have a customer that want to do HA and Dual Homing implementation. I want to ask what is the best way to implement HA for IronPort ESA? As i know the cluster configuration only used so the policy can be distributed equally. And what about dual-homing scenario? Is it supported with IronPort, and how do it works ?
Regards
Alkuin MelvinWhat exactly do you mean by multi-homing? Ironport email appliances support configuration of multiple interfaces (physical or vlan) , to which you can then attach Listeners (SMTP processes). You could thus configure your servers to receive or send email on multiple IP addresses, depending on your network config.
Sent from Cisco Technical Support iPad App -
Nexus 1000v, VMWare ESX and Microsoft SC VMM
Hi,
Im curious if anybody has worked up any solutions managing network infrastructure for VMWare ESX hosts/vms with the Nexus 1000v and Microsoft's System Center Virtual Machine Manager.
There currently exists support for the 1000v and ESX and SCVMM using the Cisco 1000v software for MS Hyper-V and SCVMM. There is no suck support for VMWare ESX.
Im curious as to what others with VMWare, Nexus 1000v or equivalent and SCVMM have done to work around this issue.
Trying to get some ideas.
ThanksAaron,
The steps you have above are correct, you will need steps 1 - 4 to get it working correctly. Normally people will create a separate VLAN for their NLB interfaces/subnet, to prevent uncessisary flooding of mcast frames within the network.
To answer your questions
1) I've seen multiple customer run this configuration
2) The steps you have are correct
3) You can't enable/disable IGMP snooping on UCS. It's enabled by default and not a configurable option. There's no need to change anything within UCS in regards to MS NLB with the procedure above. FYI - the ability to disable/enable IGMP snooping on UCS is slated for an upcoming release 2.1.
This is the correct method untill the time we have the option of configuring static multicast mac entries on
the Nexus 1000v. If this is a feature you'd like, please open a TAC case and request for bug CSCtb93725 to be linked to your SR.
This will give more "push" to our develpment team to prioritize this request.
Hopefully some other customers can share their experience.
Regards,
Robert -
SAN design : core edge and dual-homing access switch
Hello all.
It may sound as a dumb question (from a LAN guy) but when designing a core/edge or edge/ecore/edge design, why do we connect access switches to both core switches ? Doesn't it break the isolation of a dual fabric backbone ?
If an access switch fails the fault (bug or anything else) will propagate to both core switches ? Am I wrong ?
Example :
http://www.cisco.com/en/US/prod/collateral/modules/ps5991/prod_white_paper0900aecd8044c807_ps5990_Products_White_Paper.html
or from netrworkers sessions in 2006Answer also from LAN guy,
Most likely this design diagram is due to assumption that there is no use of VSANs and SAN Multipathing drivers in host.
Following is excerpt from same like yo posted.
"SAN designs should always use two isolated fabrics for high availability, with both hosts and storage connecting to both fabrics. Multipathing software should be deployed on the hosts to manage connectivity between the host and storage so that I/O uses both paths, and there is non-disruptive failover between fabrics in the event of a problem in one fabric. Fabric isolation can be achieved using either VSANs, or dual physical switches. Both provide separation of fabric services, although it could be argued that multiple physical fabrics provide increased physical protection (e.g. protection against a sprinkler head failing above a switch) and protection against equipment failure. " -
Single Homed or Dual Homed FEX
With the ability to do enhanced VPCs now on the FEXs is there any benefit to have a mixture of having of single attached FEXs and dual homed FEXs?
Here are some benefits as I see them
Single homed FEX is easier to trouble shoot as the topology is not as complex.
A dual homed FEX will support both dual attached hosts and a single attached host. So this means we only have one topology to deal with (everything dual homed)
Any other pros or cons?
ThanksIf you have any servers with only one uplink, you want dual homed FEXes for redundancy.
Also, it depend on the number of FEXes you are connecting to the same set of switches. For example: the max number of FEXes that can be uplinked to a set of 6k switches is 24 if you are dual homed, but if you are single homed the max is 48 (24 per switch).
HTH -
Fabric Extender question to a dual-homed N5k
According to latest release notes:
http://www.cisco.com/en/US/customer/docs/switches/datacenter/nexus5000/sw/release/notes/Rel_4_2_1_N1_1/Nexus5000_Release_Notes_4_2_1_N1_1.html#wp144071
"Support for a maximum of 12 Fabric Extenders dual-homed to a vPC Cisco Nexus 5000 Series switch pair and a maximum of 576 hosts connected to Fabric Extenders connected to Cisco Nexus 5000 Series switches"
I have mixed mode so some of the FEX will only connect to one N5k despite the 2N5k will be vpc. Cisco calls this "Fabric extender straight-through topology". This is because I am running port-channel with VM on these particular FEX.
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/C07-572829-00_Design_N5K_N2K_vPC_DG.pdf
question is:
1. Can I assume 2148 is included per release notes?
2. Can I have more than 2 ports in the portchannels in straight-through mode?
3. Release notes show 576 host which is (12 max times 48 ports). I assume I can have more logical host meaning vm host via the port channels, right...?
ThxAny Nexus 5000 can have a total of 12 FEX's connected to it physically. If you have 12 FEX's in dual-homed mode, then that is the limit for both Nexus 5000's. If you had 24 FEX's evenly distributed between the Nexus 5000's in straight-through mode, then that would be maximum in that configuration. If you are mixing straight-through and dual-homed configurations, you would have to be within the 12 FEX per Nexus 5000 limit.
The 2148 is the first FEX, so yes it is the focus of the release notes.
The 2148 cannot have a local port-channel. This is why you can only channel to a 2148 when using dual-homed (called Active-Active mode), one interface on each 2148, and it is tied together with a vPC configuration to make a port-channel. The individual 2148's each only have one connection on them down to the server below. The 2248 and 2232 do not have this restriction.
As of 4.2(1)N1(1), 576 refers to host interfaces. If your host has virtual hosts, you just need to make sure you are within the limit of mac addresses in the system, which is 16,000 (13,800 unicast).
Regards,
John Gill
Reference:
configuration limits -
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/configuration_limits/limits_421/config_limits_4_2_1_chapter1.html -
Hello, I read an articule of VMWare that said that VMWare ESX support SAP. But in the other hand I had read some posts that said that it is not recommended to use VMWare with SAP because they(SAP)won't give us support.
Here, we want to use VMWare ESX with SAP Portal Server and SAP MM. But only for Test and Development.
For Producction they'll have their own server.
Does anyone knows if I could implement this.
and If Any of you implement a similar solution?
Thanks
JohanHi,
Normally every customer has acces to it with their S number. If you don't have an S number, this the procedure taken from the help on service.sap.com.
The following data is needed to request a new user ID.
Note:
Please write down all your data, as you have to enter it several times and your entries always have to agree.
If you want to delete all your entries to date, click Reset.
Customer/partner number or installation number:
You will find the installation number of your SAP System under:
System -> Status... -> SAP System Data. Hint:
You only have to enter one of the numbers.
Form of address, first name, last name
When you log on to the SAP Service Marketplace, you can change this data in MyProfile.
E-mail address
You need an e-mail address that is registered at your company.
The system checks whether your e-mail address has been assigned to the entered customer/partner number.
Once you have that data:
Step 1 - Registering with the SAP Service Marketplace
Enter your customer/partner number or installation number.
Choose a form of address and enter your first and last name.
Enter the e-mail address registered with your company.
Once your entries are complete, click Send.
The User Request Successful screen appears:
You receive a registration password:
Write it down. You will need the registration password for the next step.
Within one day, you receive an e-mail with the URL link for your access data.
... Read Step 2
Hint:
If the User request failed or incomplete screen appears, your entries were incorrect.
... Read User request failed or incomplete
Top of Page
Step 2 - Request Access Data
Enter the URL link from the e-mail in your browser's address field and press Return.
The Here is your user ID and password screen appears.
Enter the following data, and make sure that it agrees with the data you entered in Step 1 - Registering with the SAP Service Marketplace:
Customer/partner number or installation number
First name and last name
E-mail address
Enter the required registration password.
When you entries are complete, click Send.
The User data registration was successful screen appears:
You receive your user ID and password.
... Read Step 3
Hint:
If the User ID generation failed screen appears, your entries were incorrect.
... Read User ID generation failed
Top of Page
Step 3 - Log On to the SAP Service Marketplace
Write down your user ID and password.
Hint:
You can change the password in MyProfile as soon as you log on to the SAP Service Marketplace.
To reach the home page of the SAP Service Marketplace, enter the following URL in your browser: http://service.sap.com.
Click Logon to SAP Service Marketplace and enter your user ID and your password.
Click OK.
You are now logged on to the SAP Service Marketplace.
Eddy -
VMWARE ESX 3.5 and Netware 6.5
I want to Install a Netware 6.5 server in VMWARE ESX 3.5 in a
IBM x3650 with 2 CPU quad core.
But the guest SO wizard don't allow me to install more than
1 CPU.
Why is that?Generally, Netware doesn't benefit from a second CPU. Of course
there are occasions where adding another CPU improves performance,
but Netware is IO bound, not CPU bound.
Under VMware, Netware will definitely perform better with a single CPU.
Netware does not idle the CPU, so when running under VMware, the
VMware tools idle the first CPU. If there are 2 CPUs, the second CPU
will always run at 100 percent utilization.
Charles
"10789" <[email protected]> wrote in message
news:[email protected]..
>
> Thanks Marcel by respuesta.But I not sure that Netware perform better
> with a single CPU . Is that true ?
>
>
> --
> 10789
> ------------------------------------------------------------------------
> 10789's Profile: http://forums.novell.com/member.php?userid=8229
> View this thread: http://forums.novell.com/showthread.php?t=314249
> -
Prime LMS 4.1 and VMWARE ESX 5.0
Can Cisco Prime LMS 4.1 be deployed on VMware ESX server 5.0 or not ?
No LMS 4.1 is not supported on ESXi 5.0. LMS 4.1 supports the following Virtualization Systems:
•VMware ESX server 3.0.x
•VMware ESX Server 3.5.x
•VMWare ESX Server 4.0.x
•VMWare ESX Server 4.1
•VMWare ESXi Server 4.0
•VMware ESXi Server 4.1
•Hyper V Virtualization (As an installable in Windows 2008)
For more details check:
http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/4.1/install/guide/prereq.html#wp1119955
On a side note, though a OVF/OVA file may be an issue, but you can try to install LMS 4.1 on a virtualized Win/Sol guest OS host, where it should work mostly. But for any issues further, Cisco or TAC may refer to this as an unsupported installation, for any t/s or support.
Else, you may upgrade to LMS 4.2 which is supported on ESXi 5.0.
-Thanks -
Hello Guys,
I have been running an old server that was installed as a test system on a DELL workstation - Optiplex GX620 (32 bit).
During the installation I had to confirgure the file: /usr/lib/vmware/installer/Core/TargetFilter.py to change the following line:
"return interface.GetInterfaceType() == ScsiInterface.SCSI_IFACE_TYPE_IDE" to read:
"return interface.GetInterfaceType() == ScsiInterface.SCSI_IFACE_TYPE_ISCSI" this made it worked and I have been using it for 3 years now. However, at this time I was hoping to update it with the latest patches and updates and I cannot figure out if I have ESXi or just ESX, nor what was my last update and what is required next.
I have used this command to get the following output:
# vmware -v
VMware ESX Server 3i 3.5.0 build-207095
... I believe the 3i indicates that I have an ESXi 3.5.0 but is build-207095 the same buid as ESXi 3.5.0 Update 5?
If not, how do I go about updating it? What is the KB # I should download?
I can manage it using vSphere Client 5.5 and I can SSH into it using Putty.
Note: When I run... "# esxupdate --bundle=ESXe350-201302401-I-SG.zip update" from within the folder where its at in the datastore, nothing happens... just a new line is scrolled.
Also...
# esxupdate query
<?xml version="1.0"?>
<query-response>
<installed-packages>
<package ID="ESX-207095">
<name>firmware</name>
<version>3.5.0</version>
<rel>207095</rel>
</package>
<package ID="ESX-CLIENT-204907">
<name>viclient</name>
<version>2.5.0</version>
<rel>204907</rel>
</package>
<package ID="ESX-TOOLS-207095">
<name>tools</name>
<version>3.5.0</version>
<rel>207095</rel>
</package>
</installed-packages>
</query-response>
/vmfs/volumes/525300ce-5ff6ad3d-e2ed-0014222aedb7/Patches/ESXe350-201302401-O-SG #
... is there any further update for this system? I believe so as the Heartbleed patch etc. was not around when I was installing this server back in 2010.Hello Richardson Porto,
I wanted to tell you that I appreciate the help so far.
Also wanted to point out to you, that the KB indicated above is older than Update 5, which from your instructions is what I have installed. That KB is for U2.
Now, the document definitely has step by step instructions on installing, querying etc. But my problem is ... NOT ALL COMMANDS WORK FOR ME!
This is why I am here because all the instructions I have been reading does not work with my flavor of ESX 3.5.0, 207095... WHY? It has me stumped.
For example, here are some commands the doc asked me to do and they failed: (Note that I had to unzip the folder on my windows box and upload it to /tmp using vSphere Client)
/tmp # ls
ESX350-201302402-BG ESX350-201302402-BG.zip vmhsdaemon-0
/tmp # unzip ESX350-201302402-BG.zip
-ash: unzip: not found -----------------------THIS COMMAND WAS NOT FOUND ?
/tmp # cd ESX350-201302402-BG
/tmp/ESX350-201302402-BG # esxupdate info
Invalid command info -----------------------THIS COMMAND WAS INVALID ?
/tmp/ESX350-201302402-BG # esxupdate update -----------------------NOTHING HAPPENED HERE ?
/tmp/ESX350-201302402-BG # ls -lh
-rw------- 1 root root 321.3k Dec 13 15:24 VMware-esx-scripts-3.5.0-988599.i386.rpm
-rw------- 1 root root 1.6k Dec 13 15:24 contents.xml
-rw------- 1 root root 701 Dec 13 15:24 contents.xml.sig
-rw------- 1 root root 1.4k Dec 13 15:24 descriptor.xml
drwxr-xr-x 1 root root 512 Dec 13 15:24 headers
/tmp/ESX350-201302402-BG #
NOTE: All these commands were run sequentially and I just copied and paste it from my SSH Client (PuTTy.exe)
Is there a toolkit I need to install to have these commands or what really am I missing here? Host is in Maintenance Mode and the 1 VM that's on it is off!
I am going to start a new discussion with this NEW ISSUE, since the Heading of this DISCUSSION has already been SOLVED! Thanks again! -
How to replace Nexus5596 with dual-homing N2K
What is the correct process to replace a FEX parent switch with dual-homing fex?
Traffic should not be interrupted.Hi
Do you have VPC between Parent Switches & are you running VPC on dual homed FEX fabric ports. ?
If yes Below is the procedure,
1) boot the replacement switch without VPC, peer-links & FEX ports connected to it.
2) Make sure it has same Software version matches with the peer switch.
3) enable Pre-Provisioning for slots with appropriate FEX model.
, here find the guide:
http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus5000/sw/system_management/521_n1_1/b_5k_System_Mgmt_Config_521N11_chapter_0100.html#task_05BB53AD7AFB49CF9A8E4A5C6C37CB38
So, on the replacement switch you will pre-provision the Fabric Extender and configure the ports so it will be ready when you add the module to the RMA SW.
Please make sure you put the appropriate FEX model on the provision slot, otherwise, when connected it will not come Online
Example, FEX 110:
N5K(config)# slot 110
N5K(config-slot)#provision model N2K-C2248T
4) Now keep all ports at Shut down state Then Configure Entire switch that includes FEX host ports, FEX Fabric Ports & VPC peer-link, VPC Domain Configuration.
keep FEX host ports in shut state.
5) keep VPC Role priority on existing switch lower than , new switch
6) Connect Peer-link ports to Peer switch & wait till VPC Comes up-
7) Then connect Fabric ports from FEX to the pre-configured ports on replacement switch
After it comes online Unshut FEX host ports.
I got similar steps here as well
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/operations/n5k_vpc_ops.html#wp425197
NOTE: I followed same process however, few ping drops were seen....arnd ( 5- 6 ping loss) only on few hosts...
Mazhar -
Solaris Cluster 3.3 on VMware ESX 4.1
Hi there,
I am trying to setup Solaris Cluster 3.3 on Vmware ESX 4.1
My first question is: Is there anyone out there setted up Solaris Cluster on vmware accross boxes?
My tools:
Solaris 10 U9 x64
Solaris Cluster 3.3
Vmware ESX 4.1
HP DL 380 G7
HP P2000 Fibre Channel Storage
When I try to setup cluster, just next next next, it completes successfully. It reboots the second node first and then the itself.
After second node comes up on login screen, ping stops after 5 sec. Same either nodes!
I am trying to understand why it does that? I did every possibility to complete this job. Setted up quorum as RDM from VMware. Solaris has direct access to quorum disk now.
I am new to Solaris and I am having the errors below. If someone would like to help me it will be much appreciated!
Please explain me in more details i am new bee in solaris :) Thanks!
I need help especially on error: /proc fails to mount periodically during reboots.
Here is the error messages. Is there any one out there setted up Solaris Cluster on ESX 4.1 ?
* cluster check (ver 1.0)
Report Date: 2011.02.28 at 16.04.46 EET
2011.02.28 at 14.04.46 GMT
Command run on host:
39bc6e2d- sun1
Checks run on nodes:
sun1
Unique Checks: 5
===========================================================================
* Summary of Single Node Check Results for sun1
===========================================================================
Checks Considered: 5
Results by Status
Violated : 0
Insufficient Data : 0
Execution Error : 0
Unknown Status : 0
Information Only : 0
Not Applicable : 2
Passed : 3
Violations by Severity
Critical : 0
High : 0
Moderate : 0
Low : 0
* Details for 2 Not Applicable Checks on sun1
* Check ID: S6708606 ***
* Severity: Moderate
* Problem Statement: Multiple network interfaces on a single subnet have the same MAC address.
* Applicability: Scan output of '/usr/sbin/ifconfig -a' for more than one interface with an 'ether' line. Check does not apply if zero or only one ether line.
* Check ID: S6708496 ***
* Severity: Moderate
* Problem Statement: Cluster node (3.1 or later) OpenBoot Prom (OBP) has local-mac-address? variable set to 'false'.
* Applicability: Applicable to SPARC architecture only.
* Details for 3 Passed Checks on sun1
* Check ID: S6708605 ***
* Severity: Critical
* Problem Statement: The /dev/rmt directory is missing.
* Check ID: S6708638 ***
* Severity: Moderate
* Problem Statement: Node has insufficient physical memory.
* Check ID: S6708642 ***
* Severity: Critical
* Problem Statement: /proc fails to mount periodically during reboots.
===========================================================================
* End of Report 2011.02.28 at 16.04.46 EET
===========================================================================
Edited by: user13603929 on 28-Feb-2011 22:22
Edited by: user13603929 on 28-Feb-2011 22:24
Note: Please ignore memory error I have installed 5GB memory and it says it requires min 1 GB! i think it is a bug!
Edited by: user13603929 on 28-Feb-2011 22:25@TimRead
Hi, thanks for reply,
I have already followed the steps also on your links but no joy on this.
What i noticed here is cluster seems to be buggy. Because i have tried to install cluster 3.3 on physical hardware and it gave me excat same error messages! interesting isnt it?
Please see errors below that I got from on top of VMware and also on Solaris Physical hardware installation:
ERROR1:
Comment: I have installed different memories all the time. It keeps sayying that silly error.
problem_statement : *Node has insufficient physical memory.
<analysis>5120 MB of memory is installed on this node.The current release of Solaris Cluster requires a minimum of 1024 MB of physical memory in each node. Additional memory required for various Data Services.</analysis>
<recommendations>Add enough memory to this node to bring its physical memory up to the minimum required level.
ERROR2
Comment: Despite rmt directory is there I gor error below on cluster check
<problem_statement>The /dev/rmt directory is missing.
<analysis>The /dev/rmt directory is missing on this Solaris Cluster node. The current implementation of scdidadm(1M) relies on the existence of /dev/rmt to successfully execute 'scdidadm -r'. The /dev/rmt directory is created by Solaris regardless of the existence of the actual nderlying devices. The expectation is that the user will never delete this directory. During a reconfiguration reboot to add new disk devices, if /dev/rmt is missing scdidadm will not create the new devices and will exit with the following error: 'ERR in discover_paths : Cannot walk /dev/rmt' The absence of /dev/rmt might prevent a failover to this node and result in a cluster outage. See BugIDs 4368956 and 4783135 for more details.</analysis>
ERROR3
Comment: All Nics have different MAC address though, also I have done what it suggests me. No joy here as well!
<problem_statement>Cluster node (3.1 or later) OpenBoot Prom (OBP) has local-mac-address? variable set to 'false'.
<analysis>The local-mac-address? variable must be set to 'true.' Proper operation of the public networks depends on each interface having a different MAC address.</analysis>
<recommendations>Change the local-mac-address? variable to true: 1) From the OBP (ok> prompt): ok> setenv local-mac-address? true ok> reset 2) Or as root: # /usr/sbin/eeprom local-mac-address?=true # init 0 ok> reset</recommendations>
ERROR4
Comment: No comment on this, i have done what it says no joy...
<problem_statement>/proc fails to mount periodically during reboots.
<analysis>Something is trying to access /proc before it is normally mounted during the boot process. This can cause /proc not to mount. If /proc isn't mounted, some Solaris Cluster daemons might fail on startup, which can cause the node to panic. The following lines were found:</analysis>
Thanks! -
BGP in Dual Homing setup not failing over correctly
Hi all,
we have dual homed BGP connections to our sister company network but the failover testing is failing.
If i shutdown the WAN interface on the primary router, after about 5 minutes, everything converges and fails over fine.
But, if i shut the LAN interface down on the primary router, we never regain connectivity to the sister network.
Our two ASR's have an iBGP relationship and I can see that after a certain amount of time, the BGP routes with a next hop of the primary router get flushed from BGP and the prefferred exit path is through the secondary router. This bit works OK, but i believe that the return traffic is still attempting to return over the primary link...
To add to this, we have two inline firewalls on each link which are only performing IPS, no packet filtering.
Any pointers would be great.
thanks
MarioHi John,
right... please look at the output below which is the partial BGP table during a link failure...
10.128.0.0/9 is the problematic summary that still keeps getting advertised out when we do not want it to during a failure....
now there are prefixes in the BGP table which fall within that large summary address space. But I am sure that they are all routes that are being advertised to us from the eBGP peer...
*> 10.128.0.0/9 0.0.0.0 32768 i
s> 10.128.56.16/32 172.17.17.241 150 0 2856 64619 i
s> 10.128.56.140/32 172.17.17.241 150 0 2856 64619 i
s> 10.160.0.0/21 172.17.17.241 150 0 2856 64611 i
s> 10.160.14.0/24 172.17.17.241 150 0 2856 64611 i
s> 10.160.16.0/24 172.17.17.241 150 0 2856 64611 i
s> 10.200.16.8/30 172.17.17.241 150 0 2856 65008 ?
s> 10.200.16.12/30 172.17.17.241 150 0 2856 65006 ?
s> 10.255.245.0/24 172.17.17.241 150 0 2856 64548 ?
s> 10.255.253.4/32 172.17.17.241 150 0 2856 64548 ?
s> 10.255.253.10/32 172.17.17.241 150 0 2856 64548 ?
s> 10.255.255.8/30 172.17.17.241 150 0 2856 6670 ?
s> 10.255.255.10/32 172.17.17.241 150 0 2856 ?
s> 10.255.255.12/30 172.17.17.241 150 0 2856 6670 ?
s> 10.255.255.14/32 172.17.17.241 150 0 2856 ?
i would not expect summary addresses to still be advertised if the specific prefixes are coming from eBGP... am i wrong?
thanks for everything so far...
Mario De Rosa -
Best Practices - VMware ESX 4.0 in a Cisco Environment?
Hello,
I'm presently designing a VMware ESX 4.0 deployment and integrating it with our Cisco environment. I've found the following document:
http://www.cisco.com/en/US/docs/solutions/Enterprise/Data_Center/vmware/VMware.html "VMware Infrastructure 3 in a Cisco Network Environment" and I was just wondering if there was a newer document applicable to ESX 4.x or if these best practices still applied?
I'm particularly interested in proper vlan design for the various port-groups with in ESX and etherchannel configuration between ESX hosts and Cisco switches.
Thanks,
RobWell, in that this is a Storage group, I'll answer froma storage noetworking point of view.
ESX hosts are no different to any other host, Just stick with the standard best practice of single initiator zoning and you'll be fine.
As a slight aside, from an array point of view, I've tended to configure all the pWWN's of the whole cluster into one "host" definition, as this makes LUN mapping easier.
Steven -
Will Crystal Reports XI run on VMware ESX 3.5 in a virtual machine
I am running VMware ESX 3.5 Update 2 Host with a Windows 2003 R2 Standard on a Virtual Machine. I initially P to V the original server that was running Crystal Reports XI to ESX but it then would not open Crystal Reports, you would click on the excutable and nothing would happen. I tried uninstalling and reinstalling and nothing changes. I then deployed a new VM from Template and reloaded Crystal Reports and the same thing happens! Does anyone have any ideas?
Thanks,
PAHi Paul
Please visit the below link:
[http://www.eweek.com/c/a/IT-Infrastructure/VMware-ESX-Update-Causing-Disruptions/]
Hope this helps!!!
Regards
Sourashree
Maybe you are looking for
-
I upgraded to OS Yosemite on my MacBook Air...and I cannot upgrade the Adobe Flash download that Adobe keeps asking me to download. I get the screen and when I click on the icon it just creates a new window but not download. Thoughts?
-
please HELP! upgraded to Mountain Lion just 3 days ago - and since then Bridge cs4 started crashing everytime it opens. did some research and tried Onyx as other users recommended - didn't help. i need Bridge for my everyday work and right now i'm g
-
Oracle 9i,10g DBA - Certificates
Hi All, I have passed Oracle 9i DBA exams (1z0-007, 1z0-031, 1z0-032, 1z0-033) respectively. And I had submitted the Course Submission Form as soon as I passed the last exam, ie, on 2/2/2010. But still now I didn't receive any mail neither from pears
-
How to find out whether an exe program is running?
HI, I'd like to run an executable program from TestStand. Before I do that I would like to check whether this program is already running? Can it be done? Thanks
-
Hi all, I am trying to insert the data in custiom infotype. for insertion i am using the following function HR_INFOTYPE_OPERATION. EXPORTING infty = '9044' number = INT_P9044-PERNR SUBTYPE