VMware vSphere ESXi Lockup

We are running VMware vSphere 4 ESXi on Sun X6450 blades with the Intel six core dunnington processors, boot from Compact Flash, iSCSI storage, 10GbE, and 92GB of RAM. The blades run fine for 10 to 30 days before completely locking up. There is no PSOD. No indication of any log that something has gone wrong. The machine simply stops responding. The issue is intermittant and apparently random. We can't find any correlation to the problem except the hardware. We are running on X6250 blades with similar configuration as well with no problem. Also, we see the problem when there is high load, when there is moderate load, and when there is no load. We have even seen it in blades which have ESXi in maintenance mode.
Has anyone seen a similar problem? If so, what is your config?

Are you using NFS? I suspect I've hit this bug on two separate X6250s while doing some I/O performance testing (Iometer testing disk access to VMDKs on NFS datastore): http://h10025.www1.hp.com/ewfrf/wc/document?docname=c01804949
My stack trace isn't exactly the same, but it's definitely an IP stack deadlock of some sort. At first, I was going to blame hardware failure on one of the newer X6250s, but then I tried another identical unit and it PSODs in just the same fashion. If it's not a "to-be-fixed-in-U5" bug, then it might be the 10Gig Multithreaded adapter driver.
Charles

Similar Messages

  • Where i can get a Cisco VMware Vsphere ESXi 4.1 update 1 installable media

    Hi All,
    can someone from cisco tell me how to get cisco vmware vsphere ESXi 4.1 update 1 that was certified by Cisco ?
    because the last release from the vmware website still 4.1 without update 1.
    http://downloads.vmware.com/d/details/esxi41_cisco_oem_iso/ZHcqYnRkdHdiZCpwcA==
    Thanks.
    Berwin H.

    Sorry for any spelling errors:
    What is working well for us, is to always get the latest ESX(i) release from vmware, apply all patches and then make sure to install the newest drivers for Cisco fnic (hba) and enic (lan) that can be found on the vmware site.
    During our first UCS upgrade (we did not have installed the Cisco drivers) we experienced some issues. A lot of our VMs lost connectivity to storage for about 2-3 minutes during the reboot of the primary FI. After opening a support request at vmware and Cisco, vmware sent us a newer fnic driver, as the standard driver included in the ESX iso did not handle hba failover very well.
    Since that upgrade we always keep up to date the enic and fnic drivers for Cisco UCS. They can be found on the VMWare ESX download site.
    Newer drivers are also available on the Cisco UCS driver CD, but those are not yet signed by vmware, so it may be a better idea to use those tested by vmware.
    Since we are handling ESX updates like this, every UCS upgrade and everything else worked like a charm and my pulse during upgrades got divided by 2
    BTW: Also with other server manufacturers we could have saved us a lot of trouble if we simply had upgraded adapter drivers earlier.

  • Vmware vsphere update manager client 5.1 update 3 fails to install

    Hi guys,
    I tried to install VMware vSphere update manager client 5.1 update 3 to upgrade the old client (5.1 update 2) and keep failing without any visible error. I notice that right after start installing sun java runtime environment  the installation fail and the rolling back process start and abort the installation. Did any of you have experience this before? if yes what is the solution.
    vCenter 5.1 update 3 Build 2306353
    ESXi 5.1.0,2191751
    Thanks in advance.

    Hi,
    Had the same problem.
    Seems to be no solution apart from uninstalling 5.1 U2, then installing 5.1 U3. (worked for me)
    It's the same problem as this KB: KB2092290, which remains unresolved.

  • Vsphere/ESXi 5.0 update 2 iso for Cisco Blade and Rackmount Servers.

    Hello Team,
    Can someone provide me details of Vsphere/ESXi 5.0 update 2  iso for Cisco Blade and Rackmount Servers.
    I tried to find it on both Cisco and Vmware websites but without success.
    It would be good if you can please share the links.
    Regards
    Deepak Jha
    +91-9873005405

    Deepak,
    From Padma's link, I found 5.0 U1, and found U2 here:
    https://my.vmware.com/web/vmware/info/slug/datacenter_cloud_infrastructure/vmware_vsphere_hypervisor_esxi/5_0#product_downloads
    I want to say, that U2 is not the customized image though
    -Kenny

  • VMware ESX/ESXi on StorageWork EVA 8400 or p6500 installation R12

    hi
    can i install oracle apps R12 on VMware Vsphere ESX/ESXi with StorageWork EVA 8xxx?
    kind regards

    Helios- Gunes EROL wrote:
    Hi;
    can i install oracle apps R12 on VMware Vsphere ESX/ESXi with StorageWork EVA 8xxx?I belive yes you can, but if it will be prod than i suggest confirm wiht oracle support for support policy
    Please see:
    http://www.vmware.com/solutions/partners/alliances/oracle-applications-whitepapers.html
    http://blogs.oracle.com/stevenChan/entry/virtualization_ebusiness_suite
    Regard
    HeliosIt will be great fortune if I came to know whether we can use it on PROD or not (in one word).
    NB:- currently I am not getting access to metalink;otherwise i shall search it by my own :D

  • Sequencing multiple versions of the VMWare vSphere client (and reducing the size of the final sequence)

    Application Name:  vSphere client
    Application Version:  4.1, 5.0, and 5.5 (all in one package)
    Company Name:  VMWare
    Sequencer Version:  5.0 SP1 or SP2
    App-V Client Version Tested On:  5.0, 5.0 SP1, 5.0 SP2
    Operating System Sequenced On:  Windows 7 (64bit)
    Pre-requisites:  Orca
    Client Operating Systems Successfully Deployed To:  Windows 7 (64bit), Windows Server 2008 (64bit)
    *Posted by non-Microsoft Employee:  Cody Lambert (a Fortune 100 company)
    If Posted by Microsoft Employee, the Corresponding KB Article Reference: 
    N/A
    Steps to Prepare and Sequence the Application:
    Phase 1:  Prepare vSphere install to be used in your sequence (to be performed prior to sequencing)
    Clear %TEMP% directory on machine you are using to prepare the install
    Create a folder that will be referred to as "vSphereInstDir"
    that install files are copied to
    Download the vSphere 5.5 client from your vSphere management server
    Run the installer for the vSphere Client
    Once at the Language Selection portion of the installer,
    using windows explorer browse to the %temp% directory and copy the files that were just created when the vSphere installer extracted to a directory (name it vSphereInstDir)
    Kill the installer
    Find VMware-viclient.exe in the files you just copied
    and run it
    Once at the "Welcome to the installation
    wizard" stage of the installer, using windows explorer browse to the %temp% directory and copy the files that were just created into the vSphereInstDir
    Kill the installer
    Find the VMware vSphere Client 5.5.msi in the vSphereInstDir,
    in the second set of files you copied over
    Using Orca, open the VMware vSphere Client 5.5.msi
    Drop the following rows from the msi (some of the rows may have additional text at the end of the names) (InstallExecuteSequence/VM_InstallHcmon,
    InstallExecuteSequence/VM_InstallHcmon_SetData,
    InstallExecuteSequence/VM_InstallUSB,
    InstallExecuteSequence/VM_InstallUSB_SetData,
    InstallExecuteSequence/VM_InstallUSBArbritrator,
    InstallExecuteSequence/VM_InstallUSBArbritratorSetData,
    InstallExecuteSequence/VM_StartUSBArbSvc) 
    Save the VMware vSphere 5.5.msi in place
    Copy the vSphereInstDir to a network location that
    can be used during sequencing on your Sequencer
    Phase 2:  Sequence the vSphere Client
    Pre-requisites:  All of the latest available VC++ redist (x64 and x86) are installed on the Sequencer VM
    Copy vSphereInstDir to your temporary install directory on your Sequencer (mine is C:\temp)
    Start up the Sequencer
    Click Create a New Virtual Application Package
    Click Next with Create Package (default) selected
    Click Next on the Prepare Computer screen, taking
    note of any findings
    Click Next with Standard Application (default) selected
    Choose Perform a custom installation, then click Next
    Input the Virtual Application name (vSphere Client
    5.5 for example)
    Enter the Primary Virtual Application Directory (C:\vSphere55
    for example) and click Next
    Using Windows Explorer find the Visual J# install (vjredist64.exe) in the vSphereInstDir you copied over.  Install using defaults
    Using Windows Explorer, find and install the vSphere client using the VMware vSphere Client 5.0.msi located in the vSphereInstDir you copied over. 
    Change the installation directory to use the Primary Virtual Application Directory you configured above (C:\vSphere55 for example).  Install using
    defaults
    While the sequencer is still monitoring changes connect to the 4.1 environment to get the files needed.  To do this, launch the vSphere client and connect
    to your 4.1 environment.  When prompted, choose RUN to install the files needed for the 4.1 environment.
    While the sequencer is still monitoring changes connect to the 5.0 environment to get the files needed.  To do this, launch the vSphere client and
    connect to your 5.0 environment.  When prompted, choose RUN to install the files needed for the 5.0 environment.
    With the sequencer still monitoring changes, after the additional environments have been installed, delete all of the language folders from the install locations
    that are not required.  You will find that there are language folders in each of the different modules that are installed.  Make sure look in every folder.  This will free up approximately 300mb from the package.
    When done, check the box to finish the sequence and continue cleaning up the sequenced application.
    Known Issues/Limitations: 
    Functions that require the USB Arbritration Service will not work
    Approximate Sequencing Time: 
    20 minutes
    Descriptive Tags: 
    App-V, 5.0, VMWare, vSphere, Recipe, Guidance
    Credit Due:  Thanks to Rorymon and Aaron Parker for accurate information that allowed for me to put together this recipe.

    Can you double check the that the following were removed from the MSI:
    InstallExecuteSequence/VM_InstallHcmon
    InstallExecuteSequence/VM_InstallHcmon_SetData
    InstallExecuteSequence/VM_InstallUSB
    InstallExecuteSequence/VM_InstallUSB_SetData
    InstallExecuteSequence/VM_InstallUSBArbritrator
    InstallExecuteSequence/VM_InstallUSBArbritratorSetData
    InstallExecuteSequence/VM_StartUSBArbSvc

  • What's the difference between OEM and standart licensing of VMware vSphere for users?

    Good day,
    Could you please explain me,
    What's the difference between OEM and standart licensing of VMware vSphere for users?

    The difference is usually the support you get. With OEM versions you'll often get support from the OEM and not from VMware directly.
    André

  • Vmware vsphere health check report v5.1.0

    Hi,
    I'm currently using the vmware vsphere health check report v5.1.0 script. I switched from another perl script to this and the report provide much more information. There is one thing that don't seem to work properly though..
    I currently have a failed disk in my server and the report is showing "unknown" status next to 3 disk / disk day. If I run the other script I have used in the past, I have 3 alerts in red clearly showing that something has failed. Would any of you know why it's showing as unknown instead of critical in the report?
    Old Script
    o Disk or Disk Bay 15 Drive 15 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 15 Drive 15 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 15 Drive 15 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 15 Drive 15 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 15 Drive 15 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 14 Drive 14 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 14 Drive 14 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 14 Drive 14 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 14 Drive 14 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 14 Drive 14 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 13 Drive 13 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 13 Drive 13 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 13 Drive 13 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 13 Drive 13 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 13 Drive 13 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 12 Drive 12 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 12 Drive 12 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 12 Drive 12 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 12 Drive 12 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 12 Drive 12 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 11 Drive 11 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 11 Drive 11 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 11 Drive 11 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 11 Drive 11 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 11 Drive 11 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 10 Drive 10 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 10 Drive 10 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 10 Drive 10 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 10 Drive 10 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 10 Drive 10 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 9 Drive 9 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 9 Drive 9 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 9 Drive 9 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 9 Drive 9 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 9 Drive 9 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 8 Drive 8 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 8 Drive 8 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 8 Drive 8 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 8 Drive 8 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 8 Drive 8 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 7 Drive 7 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 7 Drive 7 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 7 Drive 7 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 7 Drive 7 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 7 Drive 7 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 6 Drive 6 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 6 Drive 6 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 6 Drive 6 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 6 Drive 6 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 6 Drive 6 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 5 Drive 5 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 5 Drive 5 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 5 Drive 5 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 5 Drive 5 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 5 Drive 5 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 4 Drive 4 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 4 Drive 4 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 4 Drive 4 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 4 Drive 4 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 4 Drive 4 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 3 Drive 3 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 3 Drive 3 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 3 Drive 3 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 3 Drive 3 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 3 Drive 3 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 2 Drive 2 0: Drive Fault - Assert: 0
    o Disk or Disk Bay 2 Drive 2 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 2 Drive 2 0: In Critical Array - Deassert: 0
    o Disk or Disk Bay 2 Drive 2 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 2 Drive 2 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 1 Drive 1 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 1 Drive 1 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 1 Drive 1 0: In Critical Array - Assert: 0
    o Disk or Disk Bay 1 Drive 1 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 1 Drive 1 0: Rebuild In Progress - Deassert: 0
    o Disk or Disk Bay 0 Drive 0 0: Drive Fault - Deassert: 0
    o Disk or Disk Bay 0 Drive 0 0: Predictive Failure - Deassert: 0
    o Disk or Disk Bay 0 Drive 0 0: In Critical Array - Assert: 0
    o Disk or Disk Bay 0 Drive 0 0: In Failed Array - Deassert: 0
    o Disk or Disk Bay 0 Drive 0 0: Rebuild In Progress - Deassert: 0
    New Report
    BIOS 1 ABR Status 0: Unspecified - Deassert
    0
    OK
    BIOS 1 Firmware Error 0: Unspecified - Deassert
    0
    OK
    BIOS 1 Firmware Error 0: Unspecified - Deassert
    0
    OK
    Cooling Unit 1 Cooling Zone 1 0 - Fully redundant
    0
    OK
    Cooling Unit 2 Cooling Zone 2 0 - Fully redundant
    0
    OK
    Cooling Unit 3 Cooling Zone 3 0 - Fully redundant
    0
    OK
    Disk or Disk Bay 0 Drive 0 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 0 Drive 0 0: In Critical Array - Assert
    0
    UNKNOWN
    Disk or Disk Bay 0 Drive 0 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 0 Drive 0 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 0 Drive 0 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 1 Drive 1 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 1 Drive 1 0: In Critical Array - Assert
    0
    UNKNOWN
    Disk or Disk Bay 1 Drive 1 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 1 Drive 1 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 1 Drive 1 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 10 Drive 10 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 10 Drive 10 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 10 Drive 10 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 10 Drive 10 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 10 Drive 10 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 11 Drive 11 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 11 Drive 11 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 11 Drive 11 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 11 Drive 11 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 11 Drive 11 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 12 Drive 12 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 12 Drive 12 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 12 Drive 12 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 12 Drive 12 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 12 Drive 12 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 13 Drive 13 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 13 Drive 13 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 13 Drive 13 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 13 Drive 13 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 13 Drive 13 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 14 Drive 14 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 14 Drive 14 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 14 Drive 14 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 14 Drive 14 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 14 Drive 14 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 15 Drive 15 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 15 Drive 15 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 15 Drive 15 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 15 Drive 15 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 15 Drive 15 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 2 Drive 2 0: Drive Fault - Assert
    0
    UNKNOWN
    Disk or Disk Bay 2 Drive 2 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 2 Drive 2 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 2 Drive 2 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 2 Drive 2 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 3 Drive 3 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 3 Drive 3 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 3 Drive 3 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 3 Drive 3 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 3 Drive 3 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 4 Drive 4 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 4 Drive 4 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 4 Drive 4 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 4 Drive 4 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 4 Drive 4 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 5 Drive 5 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 5 Drive 5 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 5 Drive 5 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 5 Drive 5 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 5 Drive 5 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 6 Drive 6 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 6 Drive 6 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 6 Drive 6 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 6 Drive 6 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 6 Drive 6 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 7 Drive 7 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 7 Drive 7 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 7 Drive 7 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 7 Drive 7 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 7 Drive 7 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 8 Drive 8 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 8 Drive 8 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 8 Drive 8 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 8 Drive 8 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 8 Drive 8 0: Rebuild In Progress - Deassert
    0
    OK
    Disk or Disk Bay 9 Drive 9 0: Drive Fault - Deassert
    0
    OK
    Disk or Disk Bay 9 Drive 9 0: In Critical Array - Deassert
    0
    OK
    Disk or Disk Bay 9 Drive 9 0: In Failed Array - Deassert
    0
    OK
    Disk or Disk Bay 9 Drive 9 0: Predictive Failure - Deassert
    0
    OK
    Disk or Disk Bay 9 Drive 9 0: Rebuild In Progress - Deassert
    0
    OK

    Thank you for the follow up. I do understand that a completly unreadable disk might throw an unknown status but the status is different from one report than the other. On one side, it clearly shows in red that the disk has something and on the side, it just throws a "I don't know what's going on with the disk". I ran both report the same day and i'm expecting some red in the report to warn me if a disk fail.
    Is there a way to change that behavior from the health check script?

  • Cisco LMS 4.2 Appliance on VMware vSphere 4.0

    Hi all,
    I'm currently trying to install the Cisco LMS 4.2 Appliance on a VMware vSphere 4.0 environment.
    I'm following the http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/4.2/install/guide/instl.html#wp1689675
    guide.
    I downloaded the Cisco_Prime_LAN_Management_Solution_4_2.iso and I started the server.
    I get this screen and I choose option 1:
    A Welcome message appears:
    Welcome to Cisco Prime LAN Management Solution 4.2
    To boot from hard disk, press <Enter>
    The following options appears:
    •[1] Cisco Prime LAN Management Solution 4.2 Installation
    This option allows you to perform installation of LMS 4.2.
    •[2] Recover administrator password
    This option allows you to recover the administration password. Follow Step 3 to Step 17 of Recovering Admin Password on Soft Appliance Installed on VMware, to recover the administration password.
    •<Enter> Boot existing OS from Hard Disk
    This allows you to boot up the existing OS available in the hard disk.
    However, unlike the installation on my laptop (using VMware Workstation) I cannot get to this part:
    Enter the following configuration details of the server:
    •Hostname
    •IP Address
    •Subnetmask
    •Gateway
    •DNS Domain
    et cetera
    What follows looks like an installation to me.
    When this stops I get a
    localhost login:
    I cannot enter Setup as I get a password statement afterwards.
    Can somebody please help me as I'm having no idea what went wrong..
    Many thanks in advance.

    Thanks for your help, Marvin.
    We went ahead with the .ova file and it worked alright.
    We also did a little test and it seems that the .iso file does work on some VMware platforms. Our test environment had a VMware vSphere 4.1. When we started a VM with the same specs and the ISO file mounted, the installation did succeed.

  • VMware Vsphere 5.0

    Hi,
    We are looking for suggestions and advice from the users who are running Oracle EBS R12 in VMware Vsphere 5.0 environment.
    Thanks & Regards
    Chakrapani.S

    Helping the little guys think big!
    http://www.microage.com/data-center-refresh-and-server-virtualization-provides-big-benefits.html
    This topic first appeared in the Spiceworks Community

  • AMS and Vmware vSphere virtualization

    Hi,
    We are now running AMS 5 on Centos and on hardware machine with  2 quad core and 16GB memory.
    Does AMS 5 can be install and run on virtual server like Vmware vSphere ?
    I'll be appreciate to also get official answer form adobe representative.
    Thanks,
    Alon

    We haven't qualified VDI 3 yet for vSphere. But we try to do this in one of the upcoming patches.
    -Dirk

  • VMware vSphere 6.0 SR-IOV VF interface question

    Dear Sir / Madam,
    If I'd the physical server with one physical network port, can I configure the SR-IOV for 4 VF interfaces with different IP subnet?
    Means:
    VF-1 : 10.10.10.1
    VF-2 : 192.168.10.1
    VF-3 : 172.16.10.1
    VF-4 : 10.0.0.254
    It's that work for ONE physical network port?
    Thanks.

    I don't know the exact reason for this, but I think it might be related to the fact that during an OVF/IVA deployment, parameters can only be entered if the deployment process is initiated from an existing vCenter Server (i.e. not from en ESXi host). IMO the current deployment process simply provides a wrapper to successfully deploy the vCSA, independent of whether it's done in a new or an existing environment. If you take a look at the installation image's contents, you'll find the .ova file (without a file extension). Other VMware products are still shipped in an OVF/OVA, so I'm sure this format will remain a supported format.
    André

  • SCCM Inventory (Vmware/Vcores/Esxi)

    Hello All,
    We're looking into using SCCM as (one) of the main sources of information that will be used for a software asset management reporting tool. One of the key elements for getting an accurate license position is to not only determine what you have installed
    but also what the hardware beneath the virtualization layer consist of.
    I assume it's impossible to determine with SCCM (certainly in the non-hyper-v area) what the hardware of the underlying host is.
    Would other tricks as connecting VMM to vcenter deliver extra 'inventory' information to SCCM or would the above requirement lead to a connector from the reporting tool to for example vcenter to read out host data and do the vm host <> blade linking....?

    First, a (major) correction: Hyper-V is absolutely a (type 1) bare metal hypervisor.
    Next, ConfigMgr is not a CMDB. As mentioned, ConfigMgr manages OSes. It does not manage hardware. The hardware information that ConfigMgr has is because the OS exposes that information. OSes within guest virtual machines do not know or have visibility into
    their underlying hypervisor and thus ConfigMgr has no way of knowing anything.
    As for VMM, there is no real connection between VMM and ConfigMgr. Just to say it one more time, ConfigMgr manages OS instances. VMM manages hypervisors and virtual hosts. The two are complimentary, but do not overlap in purpose or functionality.
    Finally, the webcast I just presented last week in conjunction with Secunia showed how to use custom DDRs to pull information from any system, like vSphere and add that informatin to ConfigMgr for this exact scenario (I'm not sure if the recording has been
    posted yet or not though).
    Jason | http://blog.configmgrftw.com

  • Unable to install ISE 1.1.1 on VMware vSphere 5

    Dear friends,
    I'm trying to install ISE 1.1.1 VM on my vSphere 5 environment but I get no success.  I met hardware requirements (2 CPUs, 4 GB of RAM, 100 GB disk and 1 NIC), but I'm always stuck on the attached print screen (traceback and invalid ELF header of an anaconda file.
    I googled some times, but I found nothing.  What should I do to solve this?
    Thank you!

    Mauricio,
    Can you compare the md5 hash of the iso that you downloaded? Or try to download the file again and see if that fixes your issue.
    The correct md5 hash displays when you hover over the iso link, the correct hash is - ecf89ebbd50a1e77e029d35f8ae93ce9
    Thanks,
    Tarik Admani
    *Please rate helpful posts*

  • Cisco WAAS-Global policy for VMware Vsphere and/or 3par replication

    So, this is somewhat annoying that VMware Site Recovery Manager 5.0 does not seem to get much replication acceleration, mostly it is just Pass Through.  I have read a couple of Cisco marketing powerpoints that say WAAS will accelerate VMware.  But there are no Policies to that effect or configuration assistance.  So, vmware has a hundred or so connections in passthrough, all using port 44046, this web site here:
    http://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&externalId=1009562
    Shows that this is the port used for Ongoing replication, and port 31031 is used for the initial replication.  So, I have two 674-8gb with inline cards.  One in main office, one at DR office, both running 5.0.1.  The Lan ports on each side point to the LAN and the WAN interfaces on each end point to each other.  I have a layer 2 - 90Mbps link between the two locations, so "show cdp neighbor" shows the WAN interface connected.
    My question is, is there a policy I should create for this data to be accelerated and stop being "PT Asymmetric"?
    Second question, very similar to the first, 3par replication.  Same as above, but 3par uses port 5785 and the traffic shows up as "PT In Progress", there are only 6 or so connections in this state, but all are on this port 5785.
    If I pull up the pretty graphs on the CM for this device, it shows a well distributed graph, but if I click the check box for "include Pass-Through" it turns all blue and says 100% of traffic is "other-traffic"  Since 99% of what goes between these two WAAS devices is VMware site recovery manager 5.0 and 3par replication, I would really like to find a fix for this.

    ANSWER *******  SOLUTION  *******  ANSWER
    I created 2 - Optimization Policy Rules for "WAAS-GLOBAL"
    par3-rcopy, destination ports - 5785, 3491-3492, Application - Replication, TFO with DRE Adaptive and LZ
    VMware-Replication, destination ports - 44046, 31031, Application - Replication, TFO with DRE Adaptive and LZ
    Then I rebooted both WAAS devices and shut off the link for 20 minutes.  When I brought the link back online.  100% of data was accelerated, and 99% of the data was classified as "Replication" data.  I now get between 60% and 90% acceleration on this "Replication" traffic.  The final 1% is other data, remote desktop, ssl, citrix, sql, web...
    Lessons learned:  The 3par and VMware keep TCP connections open forever, and once the traffic in that session is classified as something, "other traffic" or "Pass Through" it does not change until you reset the connection.  So, if you make any changes, you have to shutdown the link, and clear all TCP connections from the WAAS devices, then it will go to a different optimization rule. 
    Final thoughts:  I am not completely sure that the Optimization policy rule "TFO with DRE Adaptive and LZ" is the BEST possible rule to use for this traffic.  If anyone has a better configuration for this traffic, I would really appreciate your input.

Maybe you are looking for

  • New feature of ios8 recent calls and message contacts do not show up across top pf screen.  What should I do?

    Iphone 5s update ios8 new feature is recent contacts from texts and calls "multitasking"  show up in circle at top pf home screen.  I don not have this feature.  Why? what should I do? There is limited information on the ios8 features on web site.  C

  • How can I get a time stamp in the historyfile

    I can´t see date and time in the history file, how can I get that information on a MAC ?

  • Mac BookPro 13" 10.6.8 extremely slow

    I have a problem with my laptop MacBook Pro 13" 10.6.8. It is running very slow since 4 or 5 weeks ago. I did a re-installation of the Mac OS X from the original DVD´s, and it is running well for 2 days, and returns the same problem. I don´t know wha

  • Where to download the TutWD_Languages_Init.zip file?

    Hi admin and experts of Web Dynpro Application, I've read the tutorial about the Internationalization of Web Dynpro Projects. In this tutorial, it needs to download the TutWD_Languages_Init.zip template file in website sdn.sap.com. But all I found ab

  • Question about image overlays

    I have what is hopefully a good question here. My final output will be 432x280. I created a graphic exactly with those dimensions, and overlaid it on the video I have ( which is original size of 1280x720) ( the graphic I overlaid is a very simple pic