VTC through PIX Firewall IP

We have IP VTC going from a Tandberg Video Conferencing bridge to a distant Tandberg and it was dropping because of the Timeout settings to I increased the timeouts and it was fine but now it intermittently fails anyone seen this before.

Are you using a gateway or border controller in network? send the details of the current problem along with a "show run" & "show version" from your PIX.

Similar Messages

  • Oracle 8i through CISCO PIX Firewall

    HI all,
    I Need some help here with CISCO PIX Firewall 506e series. The ORACLE Server 8i on Windows NT.4, placed at the inside interface of PIX Firewall.
    The Firewall has been configured to allow all the port to come from outside interface (this is where the Oracle client reside). When the client from outside try the oracle client application (where the login promt for username and password) when pressed enter the error msg
    =============================
    oracle error con 440
    unable to make connection oracle - 12514 tns.couldn't resolve service name
    the menu was not connectable with oracle. a menu is ended
    ==============================
    Many thanks for PIX and Oracle config.
    HATO

    Varun,
    Thank you for your help.
    I have one quick question, this pix is not in failover, it is standalone but it has Unrestricted license. It only has 64Mb of Ram. Will I have any problems based on your link recommendation?
    Memory Requirements:
    If you are using a PIX 515/515E running PIX Version 6.2/6.3, you must increase your memory before upgrading to PIX Version 8.0(2). This version requires at least 64 MB of RAM for Restricted (R) licenses and 128 MB of RAM for Unrestricted (UR) and Failover (FO) licenses
    What is the difference between the restricted Licenses and the Unrestricted Licenses?
    Thanks!

  • I am behind a Cisco PIX Firewall. What addresses and ports do I need to permit through to allow Firefox updates?

    I want to be able to upgrade my Firefox installations that are located behind a Cisco PIX Firewall. What are the TCP/IP addresses and ports required to be opened for updating to occur?

    This is less likely to be a firefox problem, as it appears something bad has happened to your network. Can you access the internet with other programs? Try email/ IRC/ Skype or even updating your computer.
    What operating system are you using?
    Ian.

  • PIX Firewall 525 can not start

    Hi,
    Today my colleague add 2 lines of access-list to our PIX 525.  After 10 minutes, my firewall was rebooted and until now can't start.  The booting process as listed below.
    The questions are :
    1. What is my OS version? Flash?
    2. How to remove those 2 lines (reset the config to default)?
    3. How to solve the issue?
    Thanks,
    Andy
    Booting process
    ================
    Rebooting..þ
    Wait.....
    PCI Device Table.
    Bus Dev Func VendID DevID Class              Irq
    00  00  00   8086   7192  Host Bridge
    00  07  00   8086   7110  ISA Bridge
    00  07  01   8086   7111  IDE Controller
    00  07  02   8086   7112  Serial Bus         9
    00  07  03   8086   7113  PCI Bridge
    00  0D  00   8086   1209  Ethernet           11
    00  0E  00   8086   1209  Ethernet           10
    Cisco Secure PIX Firewall Embedded BIOS Version 4.3
    Wait...ndeavor Board, Boot Block BIOS
    +------------------------------------------------------------------------------+
    |          System BIOS Configuration, (C) 2000 General Software, Inc.          |
    +---------------------------------------+--------------------------------------+
    | System CPU           : Pentium III    | Low Memory           : 638KB         |
    | Coprocessor          : Enabled        | Extended Memory      : 255MB         |
    | Embedded BIOS Date   : 08/25/00       | Serial Ports 1-2     : 03F8 02F8     |
    +---------------------------------------+--------------------------------------+
    Cisco Secure PIX Firewall BIOS (4.0) #39: Tue Nov 28 18:44:51 PST 2000
    Platform PIX-525
    System Flash=E28F128J3 @ 0xfff00000
    Use BREAK or ESC to interrupt flash boot.
    Use SPACE to begin flash boot immediately.
    Reading 1528320 bytes of image from flash.
    256MB RAM
    System Flash=E28F128J3 @ 0xfff00000
    BIOS Flash=am29f400b @ 0xd8000
    mcwa i82559 Ethernet at irq 11  MAC: 0006.5336.8129
    mcwa i82559 Ethernet at irq 10  MAC: 0006.5336.8128
                                   ||        ||
                                   ||        ||
                                  ||||      ||||
                              ..:||||||:..:||||||:..
                             c i s c o S y s t e m s
                            Private Internet eXchange
                            Cisco PIX Firewall
    Cisco PIX Firewall Version 6.2(1)
    Licensed Features:
    Failover:           Enabled
    VPN-DES:            Enabled
    VPN-3DES:           Disabled
    Maximum Interfaces: 8
    Cut-through Proxy:  Enabled
    Guards:             Enabled
    URL-filtering:      Enabled
    Inside Hosts:       Unlimited
    Throughput:         Unlimited
    IKE peers:          Unlimited
    An internal error occurred.  Specifically, a programming assertion was
    violated.  Copy the error message exactly as it appears, and get the
    output of the show version command and the contents of the configuration
    file.  Then call your technical support representative.
    assertion "addr < sfmm_chip_size" failed: file "sfmm.c", line 254
    No thread name
    Traceback:
    0: 802decd5
    1: 8007a8ce
    2: 800769bb
    3: 80078223
    4: 8007635e
    5: 800017d5
    6: 800758ab
    7: 80120ed6
        vector 0x00000003 (breakpoint)
           edi 0x8007a887
           esi 0x000000fe
           ebp 0x7ffffcb8
           esp 0x7ffffcac
           ebx 0x8007a5a3
           edx 0x000003fd
           ecx 0x0000000a
           eax 0x00000042
    error code n/a
           eip 0x802dffac
            cs 0x00000008
        eflags 0x00000046
           CR2 0x00000000
    Stack dump: base:0x7ffffc2c size:64, active:64
    0x7ffffd2c: 0x00020000
    0x7ffffd28: 0x807f2828
    0x7ffffd24: 0xfffe0000
    0x7ffffd20: 0x00000300
    0x7ffffd1c: 0x800769bb
    0x7ffffd18: 0x7ffffd48
    0x7ffffd14: 0x00000001
    0x7ffffd10: 0x00000002
    0x7ffffd0c: 0x800762f4
    0x7ffffd08: 0x804a849c
    0x7ffffd04: 0x00000020
    0x7ffffd00: 0x805100c0
    0x7ffffcfc: 0x7ffffd48
    0x7ffffcf8: 0x8007a887
    0x7ffffcf4: 0x000000fe
    0x7ffffcf0: 0x8007a5a3
    0x7ffffcec: 0x8007a8ce
    0x7ffffce8: 0x7ffffd18
    0x7ffffce4: 0x80317cd4
    0x7ffffce0: 0xffffffff
    0x7ffffcdc: 0x80078163
    0x7ffffcd8: 0x807f2828
    0x7ffffcd4: 0xfffe0000
    0x7ffffcd0: 0x805100c0
    0x7ffffccc: 0x000000fe
    0x7ffffcc8: 0x8007a5a3
    0x7ffffcc4: 0x8007a887
    0x7ffffcc0: 0x802dec68
    0x7ffffcbc: 0x802decd5
    0x7ffffcb8: 0x7ffffce8
    0x7ffffcb4: 0x00000046
    0x7ffffcb0: 0x00000008
    0x7ffffcac: 0x802dffac *
    0x7ffffca8: 0x00000042
    0x7ffffca4: 0x0000000a
    0x7ffffca0: 0x000003fd
    0x7ffffc9c: 0x8007a5a3
    0x7ffffc98: 0x7ffffcac
    0x7ffffc94: 0x7ffffcb8
    0x7ffffc90: 0x000000fe
    0x7ffffc8c: 0x8007a887
    0x7ffffc88: 0x00000003
    0x7ffffc84: 0x80004779
    0x7ffffc80: 0x7ffffcb8
    0x7ffffc7c: 0x802c4deb
    0x7ffffc78: 0x7ffffc98
    0x7ffffc74: 0x7ffffd48
    0x7ffffc70: 0x00000001
    0x7ffffc6c: 0x000000fe
    0x7ffffc68: 0x8007a5a3
    0x7ffffc64: 0x7ffffd48
    0x7ffffc60: 0x80120ed6
    0x7ffffc5c: 0x00000007
    0x7ffffc58: 0x7ffffcac
    0x7ffffc54: 0x80002d70
    0x7ffffc50: 0x7ffffc80
    0x7ffffc4c: 0x7ffffcac
    0x7ffffc48: 0x80002ab0
    0x7ffffc44: 0x00000040
    0x7ffffc40: 0x7ffffc80
    0x7ffffc3c: 0x74656720
    0x7ffffc38: 0x7ffffe28
    0x7ffffc34: 0x2c737261
    0x7ffffc30: 0x8007a887
    Nested traceback attempted via interrupt.
    Traceback output aborted.
    Rebooting..þ

    Urgent help!!!

  • Streaming WMT (netshow) through PIX with Cache Engine

    Hello:
    I am trying to stream WMT from a pre-loaded Cache engine through a PIX firewall. I would like to use UDP for the streaming, but when I start the streaming TCP is selected by default. Forcing UDP within Windows causes an error. The PIX doesn't allow the UDP traffic through since it didn't originate from the inside. Outside the firewall UDP only works if I force it. TCP is the default. First, is UDP the best way to do this or is TCP ok since it is comming from the Cache engine? Second, how can I change the Cache engine setup to default to UDP or is this not possible?
    Thank you,
    Hampton Saussy
    Midlands Technical College

    We had a similar issue. If the firewall is not configured to accept TCP ports, then the streaming video server will perform HTTP cloaking i.e Instead of using the TCP ports it will use HTTP port 80 to get through the firewall, then the server sends the streaming video data via UDP. If UDP cannot pass through the firewall, the client requests delivery via TCP. The fixup rtsp command lets PIX Firewall pass RTSP (Real Time Streaming Protocol) packets. This command does not fix RTSP UDP connections. So I guess using TCP is a better option.

  • PPTP through PIX timeout?

    We have a customer that has internal clients connecting to an outside PPTP server through a PIX firewall.
    PPTP setup works fine, but after 3 minutes the PPTP connection goes down. We are sure the PIX is the problem.
    The PIX is configured for PAT, because the customer has only 1 public IP adres. Fixup PPTP 1723 is configured.
    Does anyone know why this happens and how we can fix this?

    Hi all.
    We have same problem.
    Throgh PIX pptp sessions end after few minutes... while through other connections (other firewall, direct connection to internet and so on...) remain up properly...
    We have pix 7.0(2) release (we can't upgrade to 7.0(4) because with this release pptp sessions don't work at all....
    Thanks

  • Portal access through a firewall

    Hi there!
    Having the default installtion of R2 on a single W2K box, what's the minimal procedure to make this configuration available through a firewall?
    I've opened ports 7777-7778 but fail when trying to logon via SSO (host.domain.com:7777/pls/orasso)
    Have I missed out to open another port or am I forced to follow the steps of setting up a reversing proxy to have portal-access outside the firewall?
    Cheers
    /Staffan

    If they are on different servers, then both are listening on the 7777 port, and you will have to change one of them to use another port (assuming your firewall can only port forward a port to only one host).
    If you are running both instances on the same server, then your SSO is accessible via 7777 and your midtier would be on 7778, so your setup as described should be enough (I do the same thing).
    If they are running on the one machine, can you access the SSO/INF server directly? http://inf.domain.com:7777 and then http://inf.domain.com:7777/pls/orasso ?

  • Solaris 10 ssh through a firewall

    I have Solaris 10 up and running on an HP Vectra. Everything is fine until I attempt to ssh through my firewall from the outside world.
    I can ssh from my linux systems on the lan. But when I attempt to ssh from outside using either putty or ssh on another solaris 10 system the connection times out.
    Anyone else experience a similar problem? Many thanks in advance.
    John Wright
    Asst Professor
    CIT
    Bellevue University

    It's hard to tell what's going on without some more information. Here're a few things you can try:
    Run "ssh localhost" from the Solaris box and make sure that works.
    ssh to the Solaris box from another box on the same network segment.
    From the site that doesn't work, do "ssh -v solaris_box" and see if that gives you any clues.
    After trying to ssh from outside, do a "netstat -an |grep -i '*.22' and see the state of the TCP connection
    (or if the first packet never even makes it).
    Run sshd on the Solaris box with with the "-d" debug option.

  • Workstation Clients through a Firewall

    Does anyone out there know if there are any issues with workstation clients going
    through a firewall?
    Thanks!
    mervin

    We have done it successfully from NT to a Unix server over afirewall. Its a case
    of getting the WSNADDR set up correctly.
    use the -H option in the WSL entry in ubb config shows to set it up.
    eg
    CLOPT="-A -- -d /dev/tcp -n 0x0002nnnnxxxxxxxx -H 0x0002MMMMyyyyyyyy"
    Where nnnn is a port number
    xxxxxxxx is the true hex IP address of the server
    yyyyyyyy is the firewall hex address of the server
    MMMM is fixed.
    WSNADDR on the PC is set to port number and firewall address.
    I know the hex notation is a bit out of date these date but it works fine for
    us.
    Hope it helps
    Sue
    "Mervin Calverley" <[email protected]> wrote:
    >
    Does anyone out there know if there are any issues with workstation clients
    going
    through a firewall?
    Thanks!
    mervin

  • Whenever I try to open up Firefox, it says that it's unable to connect, however, my internet connection is fine and I can still open up Internet Explorer. I already allowed Firefox through my firewall.

    My internet connection is fine, I already allowed Firefox through my firewall. This is the first time it had ever happened and it happened suddenly, out of nowhere.

    Try "Firefox connection settings" in [[Server not found]]
    You can find the connection settings in Tools > Options > Advanced : Network : Connection<br />
    If you do not need to use a proxy to connect to internet then select No Proxy
    You can also try to remove all rules for Firefox from the permissions list in the firewall and let your firewall ask again for permission to get full unrestricted access to internet for Firefox and the plugin-container process.
    See:
    * [[Server not found]]
    * [[Firewalls]]

  • PIX firewall 525 on Voice Network for 5000 CC calls

    Dear all ,
    can some one suggest me will it be recommended to use PIX firewall 525 on Voice ( sip ) network for 5000 CC to 1000 CC calls in signaling mode since our server are using public IP so will i be able to use it without NAT / PAT also will there be any issue of QOS .
    Regards

    Sohail,
    If your idea is to add some security between your devices the PIX will work fine (I will prefer and ASA since it can run the latest software). The quality of your voice traffic shouldn't be impacted by the PIX.
    Luis Silva

  • PIX Firewall Setup

    Hi,
    I need urgent help about PIX firewall setup.......
    My one of the pix firewall flash was correpted it mean don't have flash file inside... I want to install flash file how to install...
    It's showing "monitor >"   mode.
    monitor > help
    by
    senthil

    And also i need to know how to reset password i forgot the password for the another firewall...
    I have to configure as per diagram(attached) already config is there but i need to know it's write or nor becasue this one last year one.
    Please check and let me know ASAP.
    Thanks....
    Regards,
    Senthil
    I have to configure as per diagram(attached) already config is there but i need to know it's write or nor becasue this one last year one.
    Please check and let me know ASAP.
    Thanks....
    Regards,
    Senthil

  • Endpoint on DMZ interface (through the firewall)

    Hi
    I have an ASA which connects to a BT Inifinty router. The address on the outside interface is dynamic. BT provide us with 5 static addresses (No NAT 5) which are routed to the outside interface but are a different subnet.
    I would like to terminate the site to site  VPN using one of the static IP addresses rather than the outside dynamic address.
    Can I NAT the public static address to the DMZ interface (or any interface for that matter) and terminate the VPN on that interface i.e. the firewall is terminated through the firewall?
    Thanks
    Stuart
    Update: A few people have looked but no answer. Is there some detail I need to add?

    Matheus.Omega.Mendes wrote:
    Well one solution that they found was implements one hollow interface called InterfaceWeb, just to mark the classes that works on web and desktop, although our system isn't perfectly object oriented, this solution was the worst that I ever seen. At least I think this way and I'd like to know if someone agree, disagree or have some explication for this choose.Hard to say without actually seeing it. Probably not a good idea.
    Presumably the design was driven by time to market and cost rather than just because the developers didn't want to refactor.
    As per the other suggestion, normally besides breaking the layers out you could share common functionality with a layer of its own (or several)

  • BorderManager and Pix Firewall

    Hello,
    Just implemented NSBS6.5 for a small bank with Pix firewall's inner IP
    address as my next router on hop.Was able to send mails out but could not
    receive inbound mails.Also the Bank's web site could no longer be
    assesible from within the bank but could be connected to from any where
    outside the bank's network.Could ping from the BorderManager proxy with
    public IP of 172.16.1.2 to the Pix private with IP of 172.16.1.1
    Moreover,a MaCafe Antivirus appliance was brought in and connected btw
    the BorderManager Proxy server and the Pix firewall with a bridged
    connection and an assigned IP address of 172.16.1.3 and 172.16.1.4 At
    this
    instance,could no longer ping the Pix 172.16.1.1, but could ping both
    interface of the MaCafe appliance.Could not also send nor receive mails
    via the mail proxy.
    I intend bringing the MaCafe appliance before the BorderManager Proxy
    and
    assign a LAN address to it since it has a bridged config,so as to isolate
    the problem of this appliance.
    I need to get the mail server running perfectly and the website
    assesible.Pls kindly help my case.
    Regards,
    Sesan.

    you need to go ask this in the support.bordermanager.install-setup
    group as this group is for the client firewall product only.
    Cheers!
    Richard Beels
    http://www.dsi-consulting.com
    Collaboration without complication

  • IDS,ASA,PIX firewall monitoring and optimizing

    Dear All,
    Please let me know the products from Cisco to monitor and optimize the IDS, ASA, PIX firewall in the data centre and corporate networking environment.
    I believe that VMS 2.3 can be used.I like to know about the CS-MARS product from Cisco and its usage.
    Thanking you
    Swamy

    Hi,
    CS-MARS is a security product that mainly used to analyse, correlates and produce/recommed mitigation action based on the log analysis.
    You need to send your syslog, snmp or NetFlow to CS-MARS from all/selected network devices in the network to enable it to have visibility of the network activities. It has built-in signatures or rules that trigger incidents, and allows you can create your own rule to monitor certain segment or devices. Notification is available in the form of email, sms, pager, snmp and syslog.
    CS-MARS does not replace the function of IDS/IPS or antivirus, but as a critical security complimentary product to allow you to stop any detected malicious incidents/activities from a nearest point, e.g shutting down switch port where a PC is detected trying to launch network attack, virus or trojans. The concept more or less similar to 'Forward Defense' used by certain country today.
    http://www.cisco.com/en/US/partner/products/ps6241/products_data_sheet0900aecd80272e64.html
    CS-MARS is measured by its capabilities to handle received Event and Netflow logs per second. This include the HDD capacity. You can have single unit (Local Controller) or multiple unit that centrally managed by Global Controller.
    CS-MARS support wide range of networking and security products.
    http://www.cisco.com/en/US/partner/products/ps6241/products_device_support_tables_list.html
    Rgds,
    AK

Maybe you are looking for

  • Can't authorize another computer with the same account ?

    Hello, I have 2 computers, one older than the other. - on the older, I have the old version of ADE w/ lots of ebooks on it. I had it authorized (created an account etc...). - on the new one, I have recently downloaded the new version of ADE, without

  • HOW TO CREATE AND USE ModbusSlave drivers ?

    the idea is to have a ModbusSlave driver to test the applications developed as Master modbus; with both drivers running in the same computer in both com 1 and com 2.

  • Black background/white writing

    Hi there, Just wondered if anyone knows of a phone that has a black background with white writing on all parts of the phone? Most phones at the moment have the facility to change it but the texts normally come up with white background/black writing.

  • Seq of possible taxes for country IN is limited up to 9

    Hi, We have configured the FI Tax procedure and the same condition types are using for the SD Pricing procedure. But thing is, based on our client requirements, we have created 15 condition types to arrive the accounting requirements. So, to create c

  • Elantech Touchpad Issue/Confusion on Fresh Install