VXI-MIO-64E-1 in LabWindows/CVI

I am using VXI-MIO-64E-1 module for Data Acquisition of differential Signal of 0-10V. By default Module is configured in -5V to +5V. I have used  status = AI_Configure (deviceNumber, chan, inputMode, inputRange, polarity, driveAIS) function for configure module to 0-10V unipoler but  still module is taking -5V to +5V not 0-10V.  here is LabWindows/CVI code for configuration of analog input module.
    buffer = (short *)malloc ( NUMPOINTS * sizeof(short));
   status = Init_DA_Brds (1, &brd);
   if ( status != 0 )
    MessagePopup("Error","Error in initializing VXI device");
    exit(-1);
   status = SCAN_Setup (1, NUMMODULES, ChannelList, ChannelGain);
   if ( status != 0 )
    MessagePopup("Error","Error in configuring VXI device");
    exit(-1);
   status = DAQ_DB_Config (1, 1);
   status = DAQ_Config (1, 1, 0);
   status = Select_Signal (1, ND_PFI_7, ND_IN_SCAN_IN_PROG, ND_LOW_TO_HIGH);
   if ( status != 0 )
    MessagePopup("Error","Error in Configuring SCAN_START input Line");
    exit(-1);
   InitializeTimer1();
   /* Module 1 Initialization Over */
   /* Module 2 Initialization Starts */
   buffer1 = (short *)malloc ( NUMPOINTS1 * sizeof(short));
   status = Init_DA_Brds (2, &brd);
   if ( status != 0 )
    MessagePopup("Error","Error in initializing VXI device");
    exit(-1);
   status = SCAN_Setup (2, NUMMODULES1, ChannelList, ChannelGain);
   if ( status != 0 )
    MessagePopup("Error","Error in configuring VXI device 2");
    exit(-1);
   status = DAQ_DB_Config (2, 1);
   status = DAQ_Config (2, 1, 0);
   status = AI_Configure (2, -1, 0, 10, 1, 0);
   /* Module 2 Initialization Over */
What mistake i am doing to configure module-2 to 0-10 Volt input range.

Hello Vishnu,
Unfortunately, the VXI-DAQ cards are no longer supported, but you can find information about using them in the manual.  The VXI-MIO Series User Manual  has details about setting the input range in Chapter 3 on page 3-4.
Good luck with your application!
Meghan
Applications Engineer

Similar Messages

  • Drive VXI-MIO-64E-1 in LabWindows/CVI

    I'm integrating a VXI system based NI's VXI-1394 controller in which VXI-MIO-64E-1
    was used. My develop envirenment is LabWindows/CVI 5.01. When I use the MIO
    card to sample a waveform, the only length of the waveform I can sample is
    2048Sa. Then, I insert 2 SIMM with size of 8MB to the MIO card, but it is
    useless.
    How can I configure and use the onboard Mem of VXI-MIO-64E-1? Could you give
    a sample program in CVI?
    Thank you very much!

    Hello Vishnu,
    Unfortunately, the VXI-DAQ cards are no longer supported, but you can find information about using them in the manual.  The VXI-MIO Series User Manual  has details about setting the input range in Chapter 3 on page 3-4.
    Good luck with your application!
    Meghan
    Applications Engineer

  • Looking for (2) VXI-MIO-64E-1 for purchase

    All,
    I am currently looking for (2) VXI-MIO-64E-1 multifunction cards for purchase. If you have any cards you wish to sell or know of any cards forsale, please contact me at...
    Roger A. Coffmon
    Senior Design Engineer, ATE
    [email protected]
    614-841-5871
    Liebert, NA
    www.liebert.com
    Emerson Network Power
    www.gotoemerson.com
    "Consider It Solved"

    Roger,
    Don't have what you are looking for but depending on your VXI controler there may be an alternative for you to consider. If you are using an embedded controler with a PCI expansion slot (such as 872B or 875B)you can always opt to use a PCI Data Acquisition board that meets your needs. The PCI equivalent board to the VXI-MIO-64E-1 is the PCI-6071E. You can find the product specs at the following location - http://sine.ni.com/apps/we/nioc.vp?cid=1042〈=US. This board has the functioanality equivalence with one exception, the onboard memory. So assuming you are not using the onboard memory option for the VXI-MIO-64E-1 you should have both programming and functionality transparancy.
    Regards,
    Christer

  • Visual Studio or LabWindows/CVI?

    I have a bit of a dilemma.
    I currently own Visual Studio 2010, IMAQ Vision Development Module 2013, and Measurement Studio (not sure of version). I currently do all of my programming in VB.net. Because IMAQ VDM is stuck in .Net framework 3.5 and there will be no further .net development by NI, I need to plan for the future. My applications need run on Win 8, 9, 43, or whatever my company decides to migrate to from Win 7.
    My understanding is that the NI modules I currently own will work with LabWindows/CVI. Correct? I also believe I can use them with C++ using the VS IDE. Is this also correct?
    Within my applications I do a lot of interfacing with Excel, writing text files, and interfacing to non-NI devices (cameras, DAQs, scanners, etc). I am able to do these things pretty easily using VB.net using vendor-provided SDK's.
    Therefore, my question is this...given the investment I have in software already, do I gain anything by migrating to LabWindows/CVI? What do I lose?
    I should point out that regardless of the path I choose I will need to bone up on my programming skills in the corresponding language.
    Thanks for all your help!

    Hello Steverino!
    Here are some advantages when using LabWindows/CVI over Visual Studio, which make the product more suitable for various industry-related applications:
    You are correct, LabWindows/CVI integrates with the NI platform: NI hardware and software, like TestStand or LabVIEW (e.g. debugging source code from one software to another, seamlessly).
    NI hardware and third-party hardware connectivity.
    OpenMP support.
    CVI integrates with intrument control.
    CVI Run-Time benefits from User Protection.
    Run-Time checking (e.g. for uninitialized variables).
    Scientific User Interface Controls and GUI Editor.
    Advanced debugging capabilities:
    Remote debugging support from ADE.
    Real-Time debugging support from ADE.
    Memory leak detection using the LabWindows/CVI Resource Tracking Window.
    Just-In-Time debugging.
    Deployment: build custom installers and patches that you can ship as stand-alone easy-to-use installers.
    LabWindows/CVI libraries: Advanced Analysis, Toolbox, Connectivity (Network Variables, Network Streams, DataSocket), etc.
    Support for LabWindows/CVI Toolkits: SQL Toolkit, Vision, PID, RT.
    Regards,
    - Johannes.

  • Software Development Engineer positions at Hysitron, Inc. in Minneapolis (LabWindows CVI exp preferred)

    Software Development Engineer
    Hysitron, Inc. is a premier scientific instrument manufacturer. Founded in 1992 with headquarters located in Eden Prairie, MN we are committed to promoting nanotechnology by developing advanced transducer and control technology. This leadership has made Hysitron the world leader in nanomechanical test instruments. The TriboIndenter®, TriboScope®, Ubi, and other Hysitron innovations have opened new horizons for scientists interested in investigating and understanding mechanical properties of materials at nano-scale. Hysitron fosters an environment and culture where innovation flourishes, teamwork is encouraged, and superior performance is rewarded.
    Hysitron invites applications for multiple software development engineer positions from those aspiring to explore and succeed in the nano world. Hysitron, Inc. is an Equal Opportunity Employer M/F/D/V
    Job responsibilities
    The software development engineers would be responsible for developing test and measurement software applications for nano-mechanical testing instrumentation. Job deliverables would include:
    -          Develop software applications in C based Labwindows CVI for Hysitron Instrumentation
    -          Support the development of applications to address challenges in instrument automation and control
    -          Test software applications using debugging and simulation tools
    -          Perform software releases and software quality assurance activities
    -          Participate in the design of new software products
    -          Perform maintenance activities for existing products
    -          Adapt and deliver on quality software development practices
    Minimum qualifications
    -          BS in Computer Science/ Computer Engineering/ Equivalent Scientific or engineering discipline
    -          Min of 3 yrs experience in Instrumentation software development in an industrial or R&D environment
    -          Expert at programming language C, knowledge of C++
    -          Working knowledge of various communication protocols, e.g. USB, RS232, IEEE, RS485, TCP/IP, Modbus
    -          Knowledge of general software design/documentation processes in test and measurement systems
    -          Proficient problem solving skills
    -          Strong analytical and technical skills
    -          Excellent communication and interpersonal skills
    Preferred Qualifications
    -          Proficient with LabWindows CVI and XML
    -          Working experience with DSP(Code Composer Studio) and/or FPGA level programming
    -          Exposure to digital electronics and instrumentation
    -          Working experience in Robotics interface programming
    -          Experience with Controls/Automation engineering
    Application and Information
    Qualified candidates should send a letter of application and their resumes to (please include ‘SW Engineer’ in subject line):
    Hysitron, Inc.
    10025 Valley View Rd
    Eden Prairie, MN 55344 USA
    Phone: (952) 835-6366
    Fax: (952) 835-6166
    E-MAIL: [email protected]
    Web: www.hysitron.com

    This position is still accepting resumes/CVs.

  • How do I send e-mail to a distribution list using LabWindows/CVI?

    I need to be able to send e-mail to a user-defined distribution list using LabWindows/CVI? Has anyone done this? Any ideas where I could look?

    I commented on something similar to this awhile back.  My issue was that I had the base version and didn't have the Internet classes.  So this external app worked like a charm
    It has a lot of command-line inputer options to use as well.
    http://forums.ni.com/t5/LabWindows-CVI/Need-Help-for-Sending-Email-with-LabWindows-8-5-or-9/m-p/1095...

  • How to use CAN256 and CAN257 in Labwindows CVI?

    I am trying to learn about CAN programming in LabWindows CVI. None of the samples do anything other than generate cryptic error messages. I do not have a card or interface device yet, but reading in the help files I found this:
    "NI-CAN provides a virtual CAN card with two interfaces, CAN256 and CAN257. The two virtual interfaces are connected by a virtual bus. When you write CAN frames to one virtual interface, those frames are received by the other virtual interface, and can be read as channels. This feature allows you to read and write CAN data in the same manner as two real CAN interfaces connected by a real CAN cable. The conversion does not require real NI CAN hardware, and your application is not required to check for specific CAN IDs."
    I modified the Waveform ouput project and add CAN256 to the dropdown in the uir file. However when I run it, I get the same error message as always, error -1074388725.
    Is there an example CVI code someplace to demonstrate the use of these virtual channels?

    Thanks Drew.
    Ultimately, my customer provided me with a WriteCAN256.vi and ReadCAN257.vi that were perfect for my needs. The WriteCAN256.vi along with my NI USB 8473s allowed me to provide data collection on multiple CAN devices and to verify that my Software can handle all data types from CAN devices.
    Note: My customer allowed me to share his .vi's. They are enclosed ...
    Best Regards,
    Don W
    Attachments:
    CanBus Read (Frames)_85.vi ‏55 KB
    CanBus Write (Frames)_85.vi ‏48 KB

  • How to use the checksumdll.lib in LabWindow/CVI to create CRCChecksum();

    Hi All,
    Any one know how to use the checksumdll.lib in LabWindow/CVI to create CRCChecksum() ?
    Thank you.

    Do you ave some documentation about that dll?
    Have you looked into dll properties searching for vendor name? Maybe you can look int vendorìs site and obtain some help.
    Ultimately: are you forced to use that dll or can you use any software to calculate the checksum? There are several CRCs that you can use: provided you know which is the type used you could find an algorithm to calculate the CRC and check an existing one.
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • How to set a DMA transfer type for PXIe-6536 in LabWindows/CVI?

    I have a PXI chassis PXIe-1078 with a controller PXIe-8115 running under Windows 7. The digital output board is PXIe-6536.
    I use a function DAQmxSetChanAttribute to set a property DAQmx_DO_DataXferMech to a value DAQmx_Val_DMA, since I want to use a direct memory access data transfer. This wokred well with a PCI-6534 board using the same LabWindows/CVI code before migrating it to the PXIe system.
    Unfortunately, running this code on the PXIe system reports a DAQmx error -200452: "Specified property is not supported by the device or is not applicable to the task".
    The task is created in the following simple way (the board name in MAX is 'Dev1'):
       DAQmxCreateTask ("digTask", &digitalTask);
       DAQmxCreateDOChan (digitalTask, "Dev1/port0:3", "DIG_CHANNELS", DAQmx_Val_ChanForAllLines);
       DAQmxSetChanAttribute (digitalTask, "", DAQmx_DO_DataXferMech, DAQmx_Val_DMA, 15);
    How can I solve this problem? How is it possible to choose between different transfer types?
    Thank you in advance for any hint!

    Hi CavityQED,
    The PCI-6534 is a "Digital I/O" board while the PXIe-6536 is a "High Speed Digital I/O" board, that's why they don't have the same properties.
    By the way you can use DMA transfer with this method :
    http://zone.ni.com/reference/en-XX/help/370520J-01/hsdio/direct_dma/
    Let me know if it helps you.
    Regards.
    Mathieu_T
    Certified LabVIEW Developer
    Certified TestStand Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    LabVIEW Tour
    Journées Techniques dans 10 villes en France, du 4 au 20 novembre 2014

  • How to get bar graph in word in labwindow/CVI ?

    how to get bar graph in word in labwindow/CVI ?

    ashwinic9,
    spawning your question over more and more threads (the present one, this one and this other one) won't give you a faster answer; instead, it will irritate forum users! 
    Especially if you have at your disposal a fast way to perform a test. I pointed you some days ago to word report example, that writes a table to a word document: did you tried changing the graph into a bar graph and generating the report? I have done it for you and the result is OK, as you can see in the attached document.
    Now, since the example works well, there must be something in your particular situation that prevents the graph to be shown; that is: you must add some more data on your actual problem and maybe a small example that exposes the problem.
    But please: keep active only this discussion and let the other threads die! 
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?
    Attachments:
    wordreport.doc ‏38 KB

  • I would like to know how to transform an API C++ application in MFC C++ application to use the measurement studio components or Labwindows CVI

    I don t know the way used to transform a C++ with API program in an MFC application using measurement studio or Labwindows CVI.
    Thank you for you help.

    You can use the Measurement Studio Add/Remove Components Wizard to add Measurement Studio components to your C++ application. For more information, see the "Adding and Removing Components from Measurement Studio Projects Using a Wizard" topic in the Measurement Studio reference. You can find it in the table of contents under:
    Visual C++ Help
    Tutorials
    Measurement Studio for Visual C++ 6.0
    If you're using the Measurement Studio update for Visual C++ .NET, this topic will be under:
    Visual C++ Help
    Tutorials
    Measurement Studio for Visual C++ .NET
    - Elton

  • I used to working with Labwindow CVI and i would like to know how can i use the commands "loadpanel" and "Displaypanel " in Labview. Using Invoke Nodes?

    I want to make another panel appears and runs, but i don´t want to use a subpanel. So, i would like to use somenthing similar to Loadpanel and Displaypanel, that you can use in Labwindows CVI, but in Labview, is ti possible?I hope your answers, thank you!!!

    Hi Bichillo,
    I posted an example here.
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=137&HOID=50650000000500000014570100&HTHREAD=000087828&UCATEGORY_0=_49_%24_6_&UCATEGORY_S=0
    It demonstrates how to do what you are asking.
    I do not mind you laughing at the code.
    Have fun!
    Ben

  • How does the URL of DataSocket constitute?And how to use it in LabWindows/CVI ?

    Hi !
    There's a problem puzzled me some days.How does the URL of DataSocket constitute ? And how to use it in LabWindow/CVI ?
    For example.I have downloaded a code in http://zone.ni.com/devzone/cda/epd/p/id/3787.I want to make it work properly.So I configure my DataSocket Server Manger according to the URL of this statement.
    DS_Open ("dstp://weather.natinst.com/weather/current",
    DSConst_ReadAutoUpdate, DSCurrentCallback, NULL,
    &dsCurrentHandle);
     My DateSockket Server Manger is configured as:
    However,it could not work properly when I debug it.
    There's a introduction at the top of the code."You may need to replace the references to weather.natinst.com to 130.164.140.10 if the DNS isn't working properly."So,I modified the statement into
    DS_Open ("dstp://130.164.140.10/weather/current",
    DSConst_ReadAutoUpdate, DSCurrentCallback, NULL,
    &dsCurrentHandle);
    but,it did work properly.
    We want to communicate with other computers via the URL of  DataSocket in LabWindows/CVI.Whereas,how could we make it ia the URL ?
    If anyone could help me solve this problem,I would appreciate it very much !
    Best regards.
                     xiepei
    I wouldn't care success or failure,for I will only struggle ahead as long as I have been destined to the distance.

    Hi !
    Thank you very much for your reply! I will accept your advice.
    Besides,I have another question.If I want to visit other computers or other websites,how does the URL of DataSocket  I constitute ? Does the URL has any relation with the DataSocket Server Manger ?If does,how to configure the DataSocket Server Manager to let them connected.If they have no relation,how to use the DataSocket Server Manger ?
    After all,I want to know how to use it in LabWinows/CVI ?
    Thank you very much !
    Best regards!
    I wouldn't care success or failure,for I will only struggle ahead as long as I have been destined to the distance.

  • LabWindows/CVI 2013 SP2 stops working when I try to open a file using the project file menu.

    I have windows 7 on my system and sometime late last year I starrted getting a Windows dialog telling me that LabWindows/CVI has stopped working when I try to open a file from the project file menu.  I also get an error when I run a project debug mode and use a selectFilePopup in the code.  The error says, "The program has suspended execution at address 0x75D5025E.  No source line information is available."  I've tried removing and reinstalling CVI to no avail.  Any suggestions?

    Constantin,
    Thank you for your response.  I've attached screnshots showing the version details for kernal32.dll and ntdll.dll.  I also looked at the updates to see which might have been installed when the problem started.  Unfortunately there are 15-20 updates every month.  I didn't take note of when the error started to occur.  At first it only affected my ability to open files from within the project (i.e. file->open->Source, etc).  Then I went back to modify a project that had a SelectFilePopup and found that that wouldn't work either. 
    Attachments:
    ntdll.dll version.jpg ‏15 KB

  • How to access the result list in teststand after execution using labwindows​/cvi

    I am developing a user interface in labwindows/cvi that runs multiple teststand sequence files and would like to combine their reports (generated in teststand) into a single file at the end of a UUT. What is the best way to do this? At the moment, I'm trying to access the result list local variable after the execution has ended using API calls from labwindows/cvi and an end-of-execution callback event but those run-time variables do not exist anymore. How do I get a hold of the result list array at the end of an execution? I would like to grab this variable and pass it along from sequence to sequence using labwindows/cvi and not teststand itself. Is this possible? Any help would be great.
    Thanks in advance,
    Luis

    Hey Luis,
    Check out the response to this thread at the NI TestStand board here!

Maybe you are looking for

  • BO Webi report hierarchy with measure values showing more(almost double value) compare to BW Bex report

    Hi, In our BO Webi report hierarchy with measure values showing more(almost double value) compare to BW Bex report. Can any one please help on this. Is it BW problem or BO problem? I checked in some other threads but it's not given solution. Thanks,

  • Itunes (MAc & Windows) shows no remote speakers using AIrport Express

    I have both a Win XP PC and a Powerbook G4 connected to a wireless network using a D-Link DI-624 router. Both computer can connect to the internet, the Powerbook is connected wirelessly. I've set-up my airport express on the wireless network using a

  • Neo V very Slow after ICS Update.. :(

    Updated to ICS on my Neo V and facing many issues. The major issue is that ph.is very slow and hangs a lot if 2-3 apps are running at the same time and at the time when ph. hangs not even the power button works, the only option is to reinsert the bat

  • Why all NUMBERs in OO4O are showing up as strings ???

    Hi! Whenever I create a dynaset, all the numeric fields are loaded as Strings ??? For example, I have a field defined as NUMBER(5,0). In my dynaset, the type is set to 4 (LONG) and the OraIDatatype is set to 2 (NUMBER) but the value is a really a str

  • Setting Up HP Officejet J4550

    Hello, I have downloaded the drivers for my brand new HP Officejet J4550 printer from hp.com. When I go to set up my printer, my computer is unable to find my new printer and I'm instructed to go to the hp.com website to download the appropriate driv