W.I.C.S Nationwide Error Connecting - Specified driver could not be loaded due system error 998

I am currently virtualising W.I.C.S Nationwide with APP V 5.0 SP1 on a Windows 64BIT machine. When I install and launch the application manually I am able to log into the application successfully without issues.
When I sequence the application, I get nothing in the report to suggest any issues. in fact the report has nothing. After sequencing, when testing the application on a client machine (Which is a mirror copy of the sequencing machine), once I put in the log
in credentials and try to connect with the application, I get the below error message:
Error Connecting - 2147467259 :Specified driver could not be loaded due system error 998:Invalid access to memory location. (Oracle in Installclient11_1,C:\ProgramData\App-V\86B33AE4-890E-4E98-AD4F-C4F7A1FCA0DE\4D075A01-3775-4BEA-BEC4-5414B3B0D02E\Root\instantclient_11_1\sqora32.dll).
I was wondering if anyone has had this issue with a similar application that tries to load an ODBC driver and if so how did you resolve it
UObi

When Sequencing did you try to go into ODBC and test the connection?  Is that file in that location? If you run a ProcMon, what results does that produce in relation to the sqora32.dll?
Out of interest, have you tried sequencing on a 32-bit machine? I haven't had an issue yet but am wondering if it's a 32-bit driver running on 64-bit and not running correctly for some reason, either way, a ProcMon may give you some clues. Sorry, can't be
much help
PLEASE MARK ANY ANSWERS TO HELP OTHERS Blog:
rorymon.com Twitter: @Rorymon

Similar Messages

  • ERROR [IM003] Specified driver could not be loaded due to system error 1114

    I'm seeing this error when I try to run an ASP.NET project within visual studio 2008. I've just upgraded to Windows 7. This all worked, of course, under XP.
    I'm using Oracle 10g. I can connect to the databases using SQLDEVELOPER. All of my ODBC Datasources test fine.
    The rest of the error is (Oracle in OraClient10g_home2, C:\oracle\product\10.2.0\client_2\BIN\SQORA32.DLL).
    The file is there. I opened up the permissions on the Oracle directory, so I don't think it's permissions related. I've seen a few similar errors in the forums, but no valid solutions. What's going on here?

    Is the 10g database on the local Windows 7 server ? If so, 10g is not supported/certified on Win 7, so things may or may not work.
    HTH
    Srini

  • Hadoop ODBC linked server error: Specified driver could not be loaded due to system error 182

    Hi,
    I am trying to connect to a Hadoop server through a linked server in SQL Server. I downloaded and installed the Microsoft Hive ODBC driver - HiveODBC64.msi. But while I am trying to create the Linked server using this ODBC driver I am getting below error.
    " Specified driver could not be loaded due to system error 182 (Microsoft Hive ODBC driver, D:\....\HiveODBC64.dll). (Microsoft SQL Server, Error: 7303)"
    When I tested it locally and in another server, it is working properly. I am getting this error only in this server. looks like a dll error. But cannot identify where/what is the error. Could someone help me fix this issue.
    Server info:
    OS Name: Microsoft Windows Server 2008 R2 Enterprise Version 6.1.7601 Service Pack 1 Build 7601
    SQL SERVER: Microsoft SQL Server 2008 R2(SP1)

    Hi LinkedServer,
    According to your description, you want to create linked server to connect to a Hadoop server in SQL Server, and you have created it successfully in the test server, the problem is that you get the issue in the production environment, right?
    Based on the error message, as you said it seems that the issue is related to the HiveOBDC64.dll assembly. Since you have done it on the test server, you can copy and replace HiveODBC64.dll to production server in the C:\Program Files\Microsoft Hive ODBC
    Driver\lib directory. Or you can reinstall the Microsoft Hive ODBC driver. Here is a blog which describe how to create a SQL Server Linked Server to HDInsight HIVE using Microsoft Hive ODBC Driver step by step, please refer to the link below to double check
    if your steps are correct.
    http://blogs.msdn.com/b/igorpag/archive/2013/11/12/how-to-create-a-sql-server-linked-server-to-hdinsight-hive-using-microsoft-hive-odbc-driver.aspx
    Regards,
    Charlie Liao
    TechNet Community Support

  • Specified Driver could not be loaded due to system error 5

    Hello,
    I am trying to run oracle 9i on my lap top. I installed the package from the website and got everything installed correctly. I checked my sqlnet.ora and tsnnames.ora files and the test connection in the ODBC driver is working fine.
    However, as i try and connect to the database through my ASP application i get the error:
    Code: 80004005
    Specified Driver could not be loaded due to system error 5
    I have been searching these forums for an answer and the closest solution i found was that something may be wrong with my path variable. I checked it and everything looks fine, it points to my /bin directory.
    I am not sure if it is something wrong with my driver (though i installed the latest one available) or something else. I Would appreciate any help anyone can offer.
    Thanks
    samir.

    The user that IIS runs as doesn't have appropriate access to the Oracle directory or to ODBC. There's a good, recent Usenet thread on this
    http://groups.google.com/groups?hl=en&lr=&ie=UTF-8&oe=UTF-8&threadm=3d119df8%240%24234%24ed9e5944%40reading.news.pipex.net&rnum=2&prev=/groups%3Fq%3DASP%2Bsystem%2Berror%2B5%2Bgroup:comp.databases.oracle.*%26hl%3Den%26lr%3D%26ie%3DUTF-8%26oe%3DUTF-8%26scoring%3Dd%26selm%3D3d119df8%25240%2524234%2524ed9e5944%2540reading.news.pipex.net%26rnum%3D2
    I'm assuming that you've verified that you can, say, create a new DSN with the Oracel driver and successfully test it with the "test connection" button.
    Justin

  • Specified driver could not be loaded due to system error 127: The specified procedure could not be found. (...SQORA32.DLL).

    I recently upgraded from 10g to 11g and upon this upgrade, a website of mine stopped working.
    It is a classic ASP website.  I added a "testdatabase" page to the website to test the basic functionality of opening a connection.  I've pasted the testdatabase page below.  Anyways, upon running this page, I get this error:
    Specified driver could not be loaded due to system error 127: The specified procedure could not be found. (Oracle in OraClient11g_home1_32bit, D:\app\oracleadm\product\11.2.0\client_1\BIN\SQORA32.DLL).
    I have two other environments where I have done the same upgrade and the site works just fine.  I have compared all the IIS settings in my other environments to that of the one suffering from the error.  Also, in the IIS settings, I have made sure that "Allow 32bit" was checked.
    D:\app\oracleadm\product\11.2.0\client_1\BIN\SQORA32.DLL is actually where this DLL resides. 
    I have also checked to make sure the environment variables are correct.
    The very first environment variable in the PATH setting is D:\app\oracleadm\product\11.2.0\client_1\bin; and there are no other references to oracle in the PATH environment variable.
    I have done a google search and I've seen that people also tell me to check ORACLE_HOME to make sure it's correct.  I've checked this in both of the working environments and there is nothing there.  There is also nothing there in the broken environment.  What should be there?  If anything?
    I don't know where else to look.  What could be causing this error?
    <%
    Option Explicit
    Response.Expires = 0
    Response.Buffer  = true
    Dim conn
    Err.Clear
    On Error Resume Next
    Set conn = Server.CreateObject("ADODB.Connection")
    conn.Open "DSN=RPS11;UID=FFXQM;PWD=ffxqm6prd$"
    If Err.Number <> 0 Then
    Response.Write (Err.Description & "<br><br>")
    Response.End
    conn.Close
    Set conn = Nothing
    End If
    conn.Close
    Set conn = Nothing
    On Error GoTo 0
    %>

    As a temporary solution, add the Administrators group to the IUSR and IWAM userids and see if that works. If it solves the problem, then it IS a matter of setting the users privledges correctly.

  • Specified driver could not be loaded due to system error 126

    I have some problem connecting to Oracle through ODBC. It's an ODBC error, but I cannot find anything to help me on the web so I hope someone already encounter this problem and can answer.
    So I created a new Oracle Database (SID=orcl) on one of our database server, and a user KRISS with DBA rights. It is Oracle 9i. When I tried to create a new ODBC Data Source , system DSN :
    Data Source Name : orcl
    TNS Service name : orcl
    User ID : kriss.
    when I click on Test Connection, I have the following error message :
    Unable to connect
    SQLState=IM003
    Specified driver could not be loaded due to system error 126 ( Oracle in OraHome90)
    The configuration of my system is :
    Windows 2000 Server SP3 5.00.2195
    Oracle 9i
    Any help would be great, thanks in advance,
    Kriss

    I found the answer in an other part of this forum, thank you Justin for :
    'Note that Microsoft doesn't recommend using the Microsoft ODBC driver with an Oracle9 client-- they suggest sticking with 8.1.7.
    Now that I use ODBC driver 8.1.7, I can connect to my Oracle 9i db !!!

  • SQORA32 driver could not be loaded. System error 1114: A dynamic link library (DLL) initialization routine failed

    I have an MS Access 2013 application that opens a connection to an Oracle database via an Oracle client.
    On occasion the application returns the following error when the ODBC connection is opened:
    Specified driver could not be loaded due to system error 
    1114: A dynamic link library (DLL) initialization routine failed. (Oracle in OraClient11g_home1, C:\oracle\product\11.2.0\client_1\SQORA32.DLL).
    This is an intermittent problem that is reproducible on several workstations (all running Windows 7 x64 with 32-bit version of Office 2013 and 32-bit Oracle client 11.2.0).
    Many times the ODBC connection is established without a problem
    Other times the connection can be established by closing then re-opening the application once
    Other times closing the re-opening the application several times does not help
    The same application is being run on several workstations and not every user experience the problem at the same time. The problem may be chronic for one user whereas another user experiences no problem whatsoever.
    All of the posts I have seen concerning this issue are for a persistent problem opening a connection and not an intermittent one. I am at a loss of how to diagnose this problem and would appreciate some direction.

    Hi Ross,
    This error message is Microsoft Data Link Error, this error occurs on windows when attempting to start a service or load a system driver but the DLL you loaded or one of its dependencies returned FALSE. It typically point to a system DLL file which is located
    in system32 and can be fixed by using the System File Checker tool. In your case, I suspect that it occurs due to a calling failure connecting to ODBC driver and it pointed to an error link C:\oracle\product\11.2.0\client_1\SQORA32.DLL which is hosted by oracle.
    If they are analogous, a “repair” seems to be helpful, However since we are not expert about oracle program I‘d suggest you check if C:\app\Oracle\BIN\SQORA32.DLL file exists on your machine and contact with Oracle first, I think there you can get more effective
    suggestion by other experts who familiar with design of Oracle database. Your understanding is highly appreciated.
    By the way, I searched for you and seems like you are not alone about this issue.
    https://community.oracle.com/thread/2301119
    https://communities.sas.com/message/118002
    http://forums.networkautomation.com/forum/messageview.cfm?catid=50&threadid=11611
    Please note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Regards,
    D. Wu
    Please remember to mark the replies as answers if they help, and unmark the answers if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Specified driver could not be loaded due to system error 1111 (Oracle in XE

    Trying to connect to Oracle DB from VB6
    DSN will register and test is successful in ODBC Data Source Administrator but receive above error msg when trying to connect.
    Connect_String = "DRIVER={Oracle in XE};UID=hr;PWD=hr;DBQ=XE;DBA=W;"
    Connect_String = "dsn=XE Connect;UID=hr;PWD=hr;DBQ=XE;DBA=W;"
    (neither works, same error)
    receive same error when trying to connect from MS Access to Oracle via ODBC
    W2k Professional sp4
    VB6 sp6
    Anyone have a solution?
    Thanks

    Are you sure the db is up & running?
    Has it worked before?
    Can you access the database manually?
    Have you tried to restart the OATS application service?
    Have you checked if there is a OTM schema in the XE instance?
    What is the ATS version?
    What is your operation system?
    What is your locale?
    JB

  • HT201210 I tried to restore my iPhone 4s through iTunes and received error message that Restore could not be completed due to error 2003. Phone now not recognized in iTunes, with prompt to restore, phone w/screen with iTunes symbol and can't use.

    I tried to restore my iPhone 4s through iTunes and received error message that Restore could not be completed due to error 2003. Phone now not recognized in iTunes, with repeated prompts to restore phone. Now phone w/screen with iTunes symbol and USB cord can't use. It appears the phone has been restored, but I cannot activate it.
    I disabled my anti-software, iTunes and computer software (microsoft vista) are both up to date, I restarted the computer several times. My usb ports are working properly. I followed the troubleshooting suggestions from apple.

    yes did you buy it of somebody or a well known company such as apple or carphone warehouse?
    and i mean the phone would have been activated in the first place with the sim card you get given when you first get the phone.
    trying to activate the phone with another sim card that you did not get when you brought the phone may result in you not being able to activate it
    no worries

  • VBAI - LabView interface error - "The selected inspection could not be loaded", "Inspection File Error"

    I have been programming/interfacing VBAI2012 and LV2011 for two years already.
    There is one very frustrating problem:
    - Sometimes after changing some codes in VBAI, and I switch to Inspection Interface (by clicking File->Switch to Inspection Interface), there would be error saying "The selected inspection could not be loaded"
    - and then there is NO WAY to know what is going on. It does not tell you where the error is. Its so frustrating, you changed a couple of things, and the you have error switching to Inspection Interface, but then you don't know what is causing the error.
    Is there any log file which I can check?

    Guys,
    I have resolved this issue and successfully installed and configured jive forums on my laptop.
    I have documented high level steps on my blog http://orafusionmiddleware.blogspot.com (Non revenue generating, only for knowledge sharing)
    Cheers,
    Sandeep

  • ODBC driver could not be loaded due to system error code 1114

    Hi!
    We have an application with an ODBC connection. The ODBC connection is working properly in my developer machine, via remote desktop and using it directly, in my test machine (virtual machine, accessed by remote desktop), and in the far test place, accesed by remote desktop, used by admin user or normal user. But if the tester uses the far test machine (Win XP SP3) directly, the app can't create ODBC connection: 1114.
    Instant client directory is in the path, sqlplus is working correctly used directly or via remote desktop.
    I tried Instant Client 11.2.0.3.0, 11.2.0.2.0, 11.1.0.7.0, 10. 2.0.4, 10.1.0.5, downloaded from Oracle web site.
    We did a test with process monitor. Via remote desktop loaded the sqora32.dll, called may times IRP_MJ_READ - I don't know this operation, and continued loading the dependencies: oci.dll, OraOCIEI11.dll and so on, the result was OK. Directly accessed the test computer, the sqora32.dll was loaded but did not called the IRP_MJ_READ operation. Found and loaded the oci.dll, found the OraOCIEI11.dll but did not loaded. Not tried and failed but did not loaded. And the result was 1114.
    Directly loading the driver dll, LoadLibrary failed and GerLastError reports 183 - ERROR_ALREADY_EXISTS.
    There is Remote Desktop group on the test machine, of course, but there is not specified any special security settings for it. I checked groups, the instant client directory and it's dlls.
    I haven't any really fine idea.
    Imre

    XP System error 1114 is, I believe, "A dynamic link library (DLL) initialization routine failed." That could mean several things, including (but not limited to):
    1) The setup file that you tried to install is corrupt and a re-download is needed;
    2) the .dll your install requires is corrupt, and a system re-install is suggested;
    3) the .dll your install requires is too old or too new and a different version of the download is required.
    Hard to tell from the actual messages, OS and Oracle version information and other useful stuff you have [not] posted.

  • Error :the specified module could not be found --oci.dll  : Oracle9i

    hi ,
    i m trying to connect thru my java code to the oracle on my system ,while creating the DSN it gives the error
    "the specified module could not be found" for the file oci.dll.
    earlier it was not able to look for the sqresus.dll which i copied to the winnt/system directory , and after this oci error is coming , anyone knowing it please guide
    with regards,

    Make sure it is the same version of 9i (i.e. 9.0.x or 9.2.x) for both OO4O and ODBC. Also make sure that the ORACE_BASE\ORACLE_HOME\BIN directory is in your search path AND last, check your windows directories and subdirectories for duplicate copies of OCI.DLL (or anywhere else on the PC for that matter). Sometimes MicroSoft will include one and it is usually an OLD one.

  • DBD: Error while trying to load the transport provider for odbc. Failed to load the library. System error: The specified module could not be found.

    Hello Everyone,
    We are getting an error while trying to create an Universe via Microsoft -> MS Analysis Services 2014 -> OLEDB for OLAP Provider under Connection in UDT -"DBD: Error while trying to load the transport provider for odbc. Failed to load the library. System error: The specified module could not be found."  We have installed BI 4.1 SP05 in our system. As per earlier posts in scn in BO XI 3.x this issue used to be for improper installation of Integration KIT but in our scenarion Integration KIT is within the BO 4.1 package so no seperate installation is required. Moreover I have checked whether all the driver is present under file: "C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\dataAccess\connectionServer\drivers" and seems everything is fine. But still I am getting this error. One important point is we could use IDT because in IDT still we don't have option to connect with 'Microsoft Analysis Services - 2014 (XMLA)' as we are using Microsoft Analysis Services 2014 version.
    Kindly help if anyone has faced the same problem with SAP BO 4.1.
    Thanks and Best Regards,
    Ghosal

    Hello Everybody,
    The problem is solved now after installing "OLEDB drivers from SQL Server 2012 Feature Pack". We had OLEDB drivers that comes directly from SQL Server but that did not worked out in our case.
    Thanks for your support.
    Best Regards,
    Ghosal

  • Deskjet 2542 all in one error: 'the specified module could not be found' when installing to USB

    Installation proceeds OK until the USB cable is connected, when the error message is displayed and installation ceases.
    I have successfully istalled and run the printer on another XP PC of a similar age - ie old.
    I have upgraded the XP OS to SP3 with numerous updates;
    Checked that the USB ports read Data sticks OK;
    run a/v and malware programs, including Microsoft Safety Scanner;
    checked that USB drivers are up to date;
    uninstalled driver software and re-installed with software downloaded from HP;
    carried out the procedures detailed in HP Support Forum 4022116
    Error message the same.  
    This is for my elderly neighbour - help please!
    This question was solved.
    View Solution.

    Hi @bodger50,
    Welcome to the HP Forums! 
    I understand that your HP Deskjet 2542 gives you the error: 'the specified module could not be found' when installing to USB, on Windows XP.
    I would recommend going through the steps in this post, Re: Install Error "The system cannot find the file specified" (hpzprl40.exe). When you get to the printer install wizard section, just use the full feature software and drivers found at this website, HP Deskjet 2540 All-in-One Printer series Full Feature Software and Drivers. As the printer install wizard is only for Windows 7 and up.
    Hope this is helpful, and thank you for posting!
    RnRMusicMan
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos Thumbs Up" to say “Thanks” for helping!

  • Error: The specified procedure could not be found

    Apparently the password expired on my Windows 7 BETA installation. Upon restart the system notifies me and asks for a new password. After confirming the password I get the error:
    "The specified procedure could not be found"
    I cannot log in at this point. The old password won't let me in and I can't change it. The administrator account I found is disabled by default.
    Is there any way to log in?

    Okay, here is your dilemma.
    You cannot login to your only account and the local administrator account is in its default disabled mode.
    There is a solution, albeit totally unsupported.  Go to http://www.sysresccd.org/Main_Page and download the latest SystemRescueCd.  Burn a CD from the ISO.  When you boot with the SystemRescue CD, you will type ntpass and hit <enter>.  From there, make sure you read the screens.  You will have make selections depending on how you loaded Windows 7 (clean vs. upgrade vs. dual boot, etc).  Using this disk, you CAN enable the local administrator’s account and login in.
    I just did the procedure using Windows 7, build 7000 with SystemRescueCd 1.1.6.
    Good luck.

Maybe you are looking for