"warning code 0x3b21"

I just upgraded to vista and outlook 2007.  I have installed Desktop Manager 4.6
When I try to set up the sync config I get the error message above. I know there are other threads on this, but none of them seemed to be related to outlook 2007 - any suggestions.
thanks
Solved!
Go to Solution.

Hi and welcome to the forums!
Here is what i would recommend:
First we need to clean the machine:
 http://www.blackberry.com/btsc/search.do?cmd=displ​ayKC&docType=kc&externalId=KB02206&sliceId=SAL_Pub​...
Install the correct USB drivers:
Blackberry USB and Modem Drivers ENG (DM4.6 B13)
File size: 16.988 MB
Date posted: 15-August-08
Download Software
Install and Coldboot the PC.
Download 4.6 without the Media manager here:
https://www.blackberry.com/Downloads/entry.do?code​=A8BAA56554F96369AB93E4F3BB068C22
Download manual here:
http://na.blackberry.com/eng/deliverables/3606/Des​ktop_enterprise_46_final_492866_11.pdf
Install  4.6 with these Vista considerations:
1. Right-Click on Command Prompt in Start Menu and choose Run as Administrator
2. Navigate to C:\Program Files\Research in Motion\Blackberry\IS71 Connectors\MS Outlook Connector by
    typing: c:\> CD program      files\research in motion\blackberry\is71 connectors\ms outlook connector
3. Then type in the command prompt, type: regsvr32 MsOutlookConnector.fil
4. If the registration is successful, the following message displays:
DllRegisterSErver in msoutlookconnector.fil succeeded.
5. Close and open Blackberry Desktop Manager to perform the synchronization process again and Outlook will be in the list...
If you receive the error message DllRegisterServer failed with error code 0x80070005 - you do not have admin rights. So, it's important that you run command prompt as admin. 
http://sampath.wordpress.com/2008/03/04/installing​-blackberry-desktop-software-on-vista
 On the BB:
Pull the battery while the device is ON, replace after a minute, Let the device reboot 1-3 min.
Configure DM and retry sync.
Let me know how it goes.
Thanks
Click Accept as Solution for posts that have solved your issue(s)!
Be sure to click Like! for those who have helped you.
Install BlackBerry Protect it's a free application designed to help find your lost BlackBerry smartphone, and keep the information on it secure.

Similar Messages

  • Intellisyn​c "Warning code - 0x3b21" problem with clean DM 4.6 install

    I am running Microsoft XP with Outlook 2003
    A coworker of mine bought a blackBerry bold last week and asked me if I would help set it up. I ran the installation disc to install Desktop Manager so that I could sync the bold with Outlook 2003 (we do not have an exchange server so I am using the BlackBerry Redirector). However, when I attempt to go through the initial Synchronize -> Configuration Synchronization -> Synchronization (button) setup, just before the menu displays, I receive the Intellisync "Warning encountered. Warning code - 0x3b21. Check documentation." error.
    I have tried installs from disc (DM 4.6), installs from BlackBerry's website (DM 4.6 & 4.7), and installs from AT&T's website (DM 4.6) and I receive the same error.  (NOTE - in between each new install, I performed a complete uninstall - add/remove programs, reedit, and file folder removal)
    I have browsed every post that looked even semi-related and have not found a solution that works.   
    Due to the fact that, during each of the complete uninstalls that I have performed, I have not once found a Puma Technologies folder or entry, I believe that my problem lies somewhere with that particular folder/file/program not being installed, but I need help/direction if that is the case.
    Thanks for any and all help!
    Solved!
    Go to Solution.

    So, after attempting various setups, I have discovered that my problem is not the error message "0x3b21" but rather I was trying to do something that I am not set up to do.
    When installing the Desktop software, I was selecting the "Integrate with Work Email" because that is what I wanted to do; integrate with an email account that is already set up at work. However, I did not notice the part about having an exchange server, which we do not have at our company (all of our email is routed through a web based email client through our ISP).
    Finally I tried the "Integrate with Personal Email" option and low and behold, I was able to sync my calendar, tasks, and contacts, without any problems.
    Unfortunately, I am not sure how to sync my email (which is important), but I will do more research before starting a new thread as that problem is not applicable to this thread. 

  • "No Available message stores" message and "warning code 0x3b21"

    i have Blackberry 8520, and using blackberry desktop ver 5 installed on windows 7 pro and outlook 2010. when i choose syncronization from configuration menu i recieve "No Available message stores". kindly help

    Hi and Welcome to the Forums!
    Here is a KB that discusses that error:
    KB15564 "No available message stores" appears when configuring synchronization settings in BlackBerry Desktop Manager
    Hopefully it contains something useful!
    Good luck and let us know!
    Occam's Razor nearly always applies when troubleshooting technology issues!
    If anyone has been helpful to you, please show your appreciation by clicking the button inside of their post. Please click here and read, along with the threads to which it links, for helpful information to guide you as you proceed. I always recommend that you treat your BlackBerry like any other computing device, including using a regular backup schedule...click here for an article with instructions.
    Join our BBM Channels
    BSCF General Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Intellisync Warning Code 0x3b21

    I get this code when I try to sync my 8800 and computer. Does anyone recognize this problem. It is new and previously I had sync with no problems.
    Thanks.
    Solved!
    Go to Solution.

    Check this link, and follow the steps provided by Bifocals
    http://supportforums.blackberry.com/rim/board/message?board.id=Bold&message.id=5358&query.id=131916#...
    If I help you with any inquire, thank you for click kudos in my post.
    If your issue has been solved, please mark the post was solved.

  • 4.6 sync configurat​ion error code 0x3b21

    Hi.  I've finally got desktop manager 4.6 running and my blackberry 8330 backed up.  When I try to configure syncronization for Outlook 2000, the error "Warning encountered--warning code 0x3b21 check documentation" comes up.  I'm having trouble tracking down the code/problem.  Any suggestions?
    Thanks!

    Hi,
    From what I can see in the documentation for 4.6 it does not support Outlook 2000.
    I suggest 3.6. Outlook 2000 was discontinued in 4.0
    Download 3.6 from here:
    https://www.blackberry.com/Downloads/entry.do?code​=A8BAA56554F96369AB93E4F3BB068C22
    Please let me know how it goes.
    Thanks
    Click Accept as Solution for posts that have solved your issue(s)!
    Be sure to click Like! for those who have helped you.
    Install BlackBerry Protect it's a free application designed to help find your lost BlackBerry smartphone, and keep the information on it secure.

  • Warning codes generated in UCCHECK   - Technical Upgrade - 4.0b to ECC 6.0

    Hi SDN'ers ,
    I am currently working on Technical Upgrade project from 4.0 b system to ECC 6.0 system . I am facing a
    problem relating to the analysis of the warnings displayed whehn we run the UCCHECK for the client inventory by
    checking the "Display lines that cannot be analyzed statically" option under the Selection-screen block
    "Statements that cannot be analyzed statically" .Based on the warning codes generated during UCCHECK, they can
    be classified into 12 different categories given below in the list ( Viz. ABB,MESSAGEG!C,MESSAGEG!D......MESSAGEG!P).The same are given below in the end
    I want to know
    - Which are the warning codes which need resolution so that the program does not encounter any runtime
    errors or during Integration testing ?
    - Do all the offset related errors (For example ;variable A = B+offset(length)
    or  variable A+offset(length) = B ) need resolution so that the program gives no runtime error.
    - Also, do all statements where length is calculated using STRLEN also need changes ? I have seen offset length related warnings come under MESSAGEG!M warning code.
    The objective of this is to make sure that the upgraded system ECC 6.0 in Australia ,when rolled out to
    non-English speaking geographies in APAc such as Malaysia,Japan or China would only need translations and no ABAP Coding effort even when using languages such as Japanese which have double byte characters.
    S.No.     Error Code     Message
    1     ABB     Syntax Check Aborted
         ABB Total     
    2     MESSAGEG!C      check at runtime. at runtime.
               statement because of untyped or generic operands. It can only carry out this
              The system could not perform a static convertibility check on the current
         MESSAGEG!C Total     
    3     MESSAGEG!D      out this check at runtime. It can only carry out this check at runtime.
               to a table line because of untyped or generic operands. It can only carry out
              The system could not perform a static check on convertibility from a work area
         MESSAGEG!D Total     
    4     MESSAGEG!E      check at runtime. at runtime.
               defined by a "DATA" statement. .
               statement because of untyped or generic operands. It can only carry out this
              Field "ELEMENTN" is unknown. It is neither in one of the specified tables nor
              The system could not perform a static comparability check on the current
         MESSAGEG!E Total     
    5     MESSAGEG!F      operand "<FELD1>" for the current statement. .
         MESSAGEG!F Total     
    6     MESSAGEG!G      current statement on incompletely typed operand "<DATA>". .
         MESSAGEG!G Total     
    7     MESSAGEG!H      for the incompletely typed operand "<S>". . - - - - - - - - -
              The system cannot perform a static check on a character-type field data type
         MESSAGEG!H Total     
    8     MESSAGEG!I      incompletely-typed operand "<A>" in the current statement. .
              The system cannot perform a static check on a character-type data type for the
         MESSAGEG!I Total     
    9     MESSAGEG!J      "<%_1_SYSINI>" in the current statement to check whether the operand can be
              The system cannot perform a static check on incompletely-typed operand "VALUE"
         MESSAGEG!J Total     
    Early response wil be highly appreciated.

    Hi Karthik
    >
    > 1) SPDD adjustments are done in which phase? PREPARE or UPGRADE?
    >
    SPDD is done in Upgrade ->Phase ACT_700
    > 2) Are here special cases where the adjustments need to be done before running the UPGRADE phase?
    >
    At ACT_700 phase stop the upgrade and take a backup of the DB and the PUT<DIR> before starting the SPDD activity.
    Make sure there are no pending tp request.  Either release them or delete them.
    All phase need to be completed successfully in PREPARE, before starting UPGRADE
    Cheers
    Shaji
    Edited by: Shaji Jacob on May 5, 2008 9:23 PM

  • Warning codes generated in UCCHECK

    Hi SDN'ers ,
    I am currently working on Technical Upgrade project from 4.0 b system to ECC 6.0 system . I am facing a
    problem relating to the analysis of the warnings displayed whehn we run the UCCHECK for the client inventory by
    checking the "Display lines that cannot be analyzed statically" option under the Selection-screen block
    "Statements that cannot be analyzed statically" .Based on the warning codes generated during UCCHECK, they can
    be classified into 12 different categories given below in the list ( Viz. ABB,MESSAGEG!C,MESSAGEG!D......MESSAGEG!P).The same are given below in the end
    I want to know
    - Which are the warning codes which need resolution so that the program does not encounter any runtime
    errors or during Integration testing ?
    - Do all the offset related errors (For example ;variable A = B+offset(length)
    or  variable A+offset(length) = B ) need resolution so that the program gives no runtime error.
    - Also, do all statements where length is calculated using STRLEN also need changes ? I have seen offset length related warnings come under MESSAGEG!M warning code.
    The objective of this is to make sure that the upgraded system ECC 6.0 in Australia ,when rolled out to
    non-English speaking geographies in APAc such as Malaysia,Japan or China would only need translations and no ABAP Coding effort even when using languages such as Japanese which have double byte characters.
    S.No.     Error Code     Message
    1     ABB     Syntax Check Aborted
         ABB Total     
    2     MESSAGEG!C      check at runtime. at runtime.
               statement because of untyped or generic operands. It can only carry out this
              The system could not perform a static convertibility check on the current
         MESSAGEG!C Total     
    3     MESSAGEG!D      out this check at runtime. It can only carry out this check at runtime.
               to a table line because of untyped or generic operands. It can only carry out
              The system could not perform a static check on convertibility from a work area
         MESSAGEG!D Total     
    4     MESSAGEG!E      check at runtime. at runtime.
               defined by a "DATA" statement. .
               statement because of untyped or generic operands. It can only carry out this
              Field "ELEMENTN" is unknown. It is neither in one of the specified tables nor
              The system could not perform a static comparability check on the current
         MESSAGEG!E Total     
    5     MESSAGEG!F      operand "<FELD1>" for the current statement. .
         MESSAGEG!F Total     
    6     MESSAGEG!G      current statement on incompletely typed operand "<DATA>". .
         MESSAGEG!G Total     
    7     MESSAGEG!H      for the incompletely typed operand "<S>". . - - - - - - - - -
              The system cannot perform a static check on a character-type field data type
         MESSAGEG!H Total     
    8     MESSAGEG!I      incompletely-typed operand "<A>" in the current statement. .
              The system cannot perform a static check on a character-type data type for the
         MESSAGEG!I Total     
    9     MESSAGEG!J      "<%_1_SYSINI>" in the current statement to check whether the operand can be
              The system cannot perform a static check on incompletely-typed operand "VALUE"
         MESSAGEG!J Total     
    Early response wil be highly appreciated.
    10     MESSAGEG!K      "<F_YEAR>" in the current statement to check whether the operand can be
              The system cannot perform a static check for incompletely-typed operand "WINY2"
         MESSAGEG!K Total     
    11     MESSAGEG!M      .
               at runtime. .
               check will take place at runtime. .
               entries for operand "<F_SOURCE>(2)". This check will take place at runtime. .
               entries for operand "<F_SOURCE>+2(2)". This check will take place at runtime.
              The system cannot perform a static check on the validity of the offset/length
         MESSAGEG!M Total     
    12     MESSAGEG!P      out this check at runtime. at runtime.
               statement because of untyped or generic operands. The system can only carry
              The system could not perform a static compatibility check on the current
         MESSAGEG!P Total     
         Grand Total

    Hi Monica,
                 as bhaskar said no need to worry about warnings.
    warnings will not lead to dump. only runtime errors will lead to dump.
    if the system is unicode, remediate the objects without errors.
    we can observe mainly,
    open dataset, structure incompatibilty, offset, in byte or char mode etc
    thanks
    vinod

  • Flashplayer.log Warning codes 1474 and 1475

    Hello,
    I am using an internal server to push updates to our flash player in a test environment. I have the current version of 15.0.0.189 installed on my client machines, and the same version on my internal server. I am attempting to verify functionality by examining the flashupdate.log file. It seems that everything is working, however i have 2 [warning] codes in my log and I was hoping i could get some assistance in figuring out what they are.
    My system info is this:
    Client system: Windows 7 Professional 32bit
    Client Flash Version: 15.0.0.189
    Server System: Windows Server 2012
    Server Flash Version: 15.0.0.189
    Server File Structure:
    An excerpt of my log follows. Obviously the myflashupdate.server is a placeholder for my actual server.
    <-----BEGIN LOG---->
    2014-10-28+15-46-0.198 [info] 1628 myflashupdate.server
    2014-10-28+15-46-0.198 [info] 1629 myflashupdate.servero
    2014-10-28+15-46-0.198 [info] 1614
    2014-10-28+15-46-0.198 [info] 1615
    2014-10-28+15-46-0.214 [info] 1618
    2014-10-28+15-46-0.214 [info] 1619 1063
    2014-10-28+15-46-0.245 [info] 1628 myflashupdate.server
    2014-10-28+15-46-0.245 [info] 1629 myflashupdate.server
    2014-10-28+15-46-0.245 [info] 1614
    2014-10-28+15-46-0.261 [info] 1615
    2014-10-28+15-46-0.261 [info] 1618
    2014-10-28+15-46-0.261 [info] 1604
    2014-10-28+15-46-0.261 [info] 1608
    2014-10-28+15-46-0.276 [info] 1631 /pub/flashplayer/update/current/sau/currentmajor.xml
    2014-10-28+15-46-0.354 [warning] 1474 12044
    2014-10-28+15-46-0.354 [warning] 1475
    2014-10-28+15-46-0.354 [info] 1432
    2014-10-28+15-46-0.370 [info] 1612
    2014-10-28+15-46-0.370 [info] 1620
    2014-10-28+16-46-0.180 [info] 1628 myflashupdate.server
    2014-10-28+16-46-0.180 [info] 1629 myflashupdate.server
    <----END LOG---->
    Does this log mean my updates are working correctly (Aside from trying to pull the same version as the one installed)?
    What are the 2 Warning codes?
    Thanks you for any and all replies!

    Thanks for your reply!
    I didn't notice somehow that the folders were only listed in my screenshot. the currentmajor.xml is in the sau directory as showcased by the screenshot below. the contents are:
         \sau\currentmajor.xml
    <version>
          <Player major="15" majorBeta="15" />
    </version>
    \sau\15\xml\version.xml
    <?xml version="1.0" ?>
    <version>
         <ActiveX major="15" minor="0" buildMajor="0" buildMinor="189" />
         <Plugin major="15" minor="0" buildMajor="0" buildMinor="189" />
         <MacPlugin major="15" minor="0" buildMajor="0" buildMinor="189" />
         <SAUConfig checkFrequency="1" />
    </version>

  • CIFS[17138]: WARNING: CODIR: Failed to add share "MDATA" to

    Can someone tell me how to get rid of the message
    Code:
    CIFS[17138]: WARNING: CODIR: Failed to add share "MDATA" to eDirectoy. Error: 0

    Originally Posted by susehoush
    cluster -> yes (3node sles10sp3+oes2sp3)
    There is a nss volume object and a pool object and their attributes seem to be ok.
    We also get the following 2 errors:
    Code:
    CIFS[17138]: ERROR: ENTRY: CIFSNDSGetCIFSServerInfo: isVirtualServer = FALSE, uServerVersion = %U, aServerVersion = e, expected = %U
    ERROR: CODIR: LockDirCacheEntry failed to open file for User
    Ok, This thread might be of interest (mainly the clarification in post #25) http://forums.novell.com/forums/nove...ols-howto.html
    And the related TID (only as a reference in this case, not meant to apply that added python script) : CIFS not enabled properly on cluster resource that was created before upgrading to OES2 SP2
    Curious if you are trying to add CIFS after having created the resources? But then still, it should not be an issue anymore (as in should have been fixed).
    -Willem

  • List of warning codes

    Is there a document which lists warning codes (positive numbers returned as function status) and corresponding messages?
    Mark

    It's not exactly a help document, but you can find the numbers and symbolic names in the file nidaqmx.h that comes with the driver. It's part of the C-code support.
    John Weeks
    WaveMetrics, Inc.
    Phone (503) 620-3001
    Fax (503) 620-6754
    www.wavemetrics.com

  • W3c warning code?

    Whilst Validating my index page i recieved a pass but a
    warning - any idea what i need to do? Thanks Kylie
    Line 24, Column 18: reference to non-existent ID
    "ViewProducts".
    <label for="ViewProducts"></label>✉
    This error can be triggered by:
    A non-existent input, select or textarea element
    A missing id attribute
    A typographical error in the id attribute
    Try to check the spelling and case of the id you are
    referring to.

    You really need to study your HTML. The answer *should* be
    blindingly
    obvious.
    You have a form on your page. In that form, you have a
    <label> tag that is
    set to apply to a field called "ViewProducts" -
    <label for="ViewProducts"></label>
    But you do not have such a field in your form. This error
    could be caused
    by -
    A non-existent input, select or textarea element (thus you
    don't have the
    field in your form)
    A missing id attribute (you have a field, but have not given
    it the
    "ViewProducts" ID)
    A typographical error in the id attribute (you have a field,
    but have its
    ID could be "viewProducts" or "Viewproducts" or
    "viewporducts" or
    "monkeybutt")
    So - the solution is LOOK AT YOUR CODE. Think about the error
    message.
    Decide what to do.
    Murray --- ICQ 71997575
    Adobe Community Expert
    (If you *MUST* email me, don't LAUGH when you do so!)
    ==================
    http://www.projectseven.com/go
    - DW FAQs, Tutorials & Resources
    http://www.dwfaq.com - DW FAQs,
    Tutorials & Resources
    ==================
    "PracticalPJ'Z" <[email protected]> wrote in
    message
    news:glu2ov$8jc$[email protected]..
    > Hi Murray, you are a life saver thanks for this help.
    >
    > So does that mean i need to click on the view products
    menu and create a
    > css
    > rule for it ? I simply deleted the text out of my code
    as I didnt know
    > what to
    > do.
    >
    > OR do i go to properties panel and allocate a format
    such as a h1 ?
    > paragraph?
    > :) Kylie
    >

  • Using Warnning Code

    Hi,
    I want to override the warning/error comment in java, Which class should I import ?
    How Can I use that ?
    For example :
    I want to implement a comment as an eclipse's plugin, and for that somehow I need to use a specified comment,
    I wanto to override/use the comment "variable never real locally" .
    Where Can I found all these warnings/erros ?
    Thanks .

    Not only to change the text .. but also to verfiy in running time "online" that this comment is given .
    I want to add in my code such a thing :
    int x ;
    bla bla bla ....
    if(x is never readl locally ) then ..... .
    My question how can I do such a condition to use a comment in my code ???
    Thanks tschodt .

  • Failure of Mapping Returning  Warning Code

    Hi All
    I am finding that when a mapping activity fails in a process flow, the data flow proceeds
    along warning transition as opposed to error transition.
    Has anyone come across this please ?
    Regards
    AZ

    While I can't say if my circumstance is identical, I can state that I have experienced the same issue under a specific circumstance: When doing an insert/update set-based against a target table where DML error logging is in play. In that instance, exceeding the max errors properly rolls back the transaction in the target table and leaves the errors in the error table, however the return value is "OK_WITH_WARNINGS" instead of the expeced failure status. this was with the latest 10 version as we haven't yet upgraded to 11.
    Cheers,
    Mike

  • Lost start up internal disc and getting SUID File warning code?

    In spite of everyone saying this is normal "SUID file "system/library/core services/remoteManagement/ARDAgent.app/Contents/MacOS/ARD/agent" has been modified and will not be repaired. It is not a normal thing? My Mac is only three moths old, and I downloaded Lion, lost my Microsoft apps, resumes, and all my back up in icloud? Whole library crashed and it's a mess. Now there is now start up disc in the system? Very annoying.

    If you repair Permissions and get the message Permissions repair complete, then go back and repair again, anything that reappears is not really an "error." Just ignore it.
    If the Lion upgrade from Snow Leopard did all that and you have no backup to restore, then you're out of luck. But I don't understand how you went from Snow Leopard on a three months old machine. It wouldn't have come with Snow Leopard and Snow Leopard couldn't have been installed on it. Maybe you want to clarify.
    EDIT: this would appear now to be a Lion, not a Snow Leopard issue. Why don't you ask for help in the Lion forum? Perhaps there are some fixes for your issues.
    https://discussions.apple.com/community/mac_os/mac_os_x_v10.7_lion?view=discussi ons
    Message was edited by: WZZZ

  • 0x3b21 Intellisyn​c Error during Sync Process

    Tried to do a Sync and in DTM under Sync I have these checked:
    Reconcile Messages
    Synchronize organizer data (If this is unchecked I DO NOT get this error message)
    Update device data and time
    As I watch it go through its Sync screens, right before it gives this error it shows a screen that says something to the effect of "Setting up default system configuration" and then boom it pops up this error.
    Intellisync (Shown in Top Bar of box)
    Warning encountered. Warning Code - 0x3b21.
    Check Documentation
    I have followed the instructions listed Bifocals forum (http://supportforums.blackberry.com/t5/BlackBerry-​Bold-BlackBerry-9000/Bold-quot-Warning-code-quot/m​...) listing to the "T" and it did not work for me. When I downloaded the software he had linked the computer said "Software not found" after installing it. I tried again and it said the same thing. I then went to Software Download center and downloaded the 4.6 version without Media Manager and it still does the same error.
    Any ideas? Maybe I'm missing something that one of you can point out.
    Hail
    Curve 8330m

    Hi there!
    Here are some KBs that discuss that error:
    KB17365 "Warning encountered. Warning code - 0x3b21. Check documentation"
    KB17307 "Warning encountered. Warning code - 0x3b21. Check documentation", error appears when configuring the synchronization in the BlackBerry Desktop Manager
    Hopefully they contain something useful!
    Good luck and let us know!
    Occam's Razor nearly always applies when troubleshooting technology issues!
    If anyone has been helpful to you, please show your appreciation by clicking the button inside of their post. Please click here and read, along with the threads to which it links, for helpful information to guide you as you proceed. I always recommend that you treat your BlackBerry like any other computing device, including using a regular backup schedule...click here for an article with instructions.
    Join our BBM Channels
    BSCF General Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

Maybe you are looking for

  • Time duration for Process.waitFor() to wait.

    Can we specify the time duration for the Process.waitFor() after which it resumes?           Runtime rt=Runtime.getRuntime();           Process ps=rt.exec("some command");           ps.waitFor(); Like here if rt.exec() is taking a lot of time to exec

  • How to manipulate Informix's collection columns in JDBC ?

    Howdy, Please does anyone have any examples of how to use informix's collection columns via JDBC? (I'm specifically interested in list) IBM (the worlds third? largest computer company) has the worst website on the planet. It's near impossible to find

  • SAP Best Practice for Discrete Manufacturing

    Hi colleagues, We are installing SAP BP for Discrete Manufacturing based on ECC 6.00. We have already installed the Baseline Layer 0. The problem we face now is that some of the building blocks required for Layer1 activation are not present amongst t

  • DPS Viewer for Android mobiles

    Since we launched our publication on the IPAD and the IPhone, we have been receiving alot of requests from customers to launch the publication on android devices. After doing some survey, most of the requests are coming from people with Samsung S2, S

  • Final 4.6c release

    where can I find info on when the final 4.6c patch will be release from SAP? thanks for any leads.