Wartsila MII Integration

Hello everbody,
Do you have any experience about integration between Wartsila SCADA system for power plants and SAP MII?

This is the first time I've heard of Wartsila, and my Google searches didn't reveal too much information.  It appears that the data may be a bit proprietary, but WOIS (Wärtsilä Operatoru2019s Interface System) and WISE (Wärtsilä Information System Environment) appear to be the possible data locations.
There are some diagrams and discussions in these two pdf's, but I'm not finding much insight on their main website.
http://www.wartsila-nsd.com/Wartsila/global/docs/en/power/media_publications/energy_news/21/plant_automation_today.pdf
http://www.wartsila.com/Wartsila/global/docs/en/about_us/twentyfour7/1_2007/power_plant_automation.pdf
The PLC's may be your only option, through an OPC Server, but neither Matrikon or KepWare searches produced any matches for WOIS, WISE, Wartsila, or Wärtsilä

Similar Messages

  • Siemens DIS to MII integration

    I am exploring possibilities of SIMATIC IT Data Integration with SAP MII 12.0.
    Siemens DIS provides HTTP client & server connectors. HTTP server connector can poll remote MII server in every n seconds and can pick whenever new response gets generated in MII.
    Another possibility is to use COM connector as a bridge to Siemens DIS system. It allows any third party application which supports COM technology to connect to DIS. So here I see a need to have a Windows COM application hosted on IIS that can support COM and start the COM connector as in-process COM server. MII can do Web Service call to custom application to trigger the DIS.
    Second approach gives trigger to MII without continuous polling by DIS.
    I will appreciate all the responses on it.
    Thanks
    Ram Upadhayay

    Cemil,
    answer to your questions:
    1- Is it possible use UDS OPC-HDA with winCC?
    Yes it is possible.
    2- Which component must be installed at winCC side?
    You need the a additional License ([WinCC/Connectivity Pack|http://www.automation.siemens.com/hmi/html_76/products/software/wincc_optionen/connectivity-pack.htm]) in WinCC for HDA. Also you need to customize it.
    3- WinCC OPC-DA Server is different server or winCC server?
    WinCC OPC-DA and WinCC OPC-HDA is on the same Server
    Regards
    Pedro Iglesias

  • Install a Test/Dev instance for SAP MII.

    Hi,
    I want to install a test/development instance for SAP MII on my laptop [2 GB RAM].
    Per my understanding, for this i would need set up SAP NetWeaver CE instance and deploy SAP MII 12.1 component.
    I also want do some custom development & integration with SAP through MII to SAP ME.
    As per Master Guide SAP MII 12.1.pdf, we need to Install SAP NetWeaver CE 7.1 EHP1 SP03.
    Since its a test/development instance can i install [SAP NetWeaver Composition Environment 7.2 Developer Edition|http://www.sdn.sap.com/irj/scn/downloads?rid=/library/uuid/a0a6bd7b-3dfc-2c10-eb95-aae0f777d4ab] and deploy MII.?
    Or do i need to have some specific version of Netweaver CE.
    Please let me know what are steps to install a Test/Dev environment for SAP ME/MII integration..
    Please advice.
    Thanks un advance.

    MII 12.1 has not been validated on NWCE 7.2.  And MII 12.2 is validated on NW 7.3, skipping NWCE 7.2.  It may install fine, but you will most likely run into problems executing some of the functions and features of MII.
    Regards,
    Mike

  • MII working together with HANA

    Hi ,
    I recently started to have a look at SAP HANA, impressive technology I must say.
    Now my question is how do you see MII integrating with HANA, and will MII in your view/opinion have a place once HANA takes off ?
    Has anyone had experience in doing such an integration yet, or planning to ?
    Is there any one maybe in the MII development team that has an opinion or view on this ?

    HANA's strength is in processing massive amounts of data, very rapidly.  MII has a number of strengths (connectivity, integration of different data sources, rapid development of dashboards, etc.).  Not sure where a point of competition would occur. 
    One area that they could share (IMHO) would be analytics applied to process historians (who have huge amounts of data).  Not sure who is working on this, if anyone.  But there would be some great amounts of data which could be analyzed by HANA and perhaps presented or distributed by MII.
    Regards,
    Mike

  • Reference Document Loader.

    Hi,
    I'm studiying some MII integrations.It was given me sample .XML document .
    I must use this document for mapping with some data.
    I used reference document loader to load sample .XML document.
    1- I must make empty inside it.
    2- How can i use that .xml document? Must i use Document and Row action? How?
    3- Or it must be used Reference Schema Loader?
    Thanks

    Hi
    You can go through this link for how to use Reference Document Loader Action.
    http://help.sap.com/saphelp_xmii115/helpdata/en/Business_Logic_Services/referencedocumentloader.htm

  • Unable to Link a Notification to an Order

    Hi Experts,
    I am trying to create an order linked to a notification and can able to do it too.
    But when i go to IW32 (Order Details ) i cannot see the Notification assigned to Order at header level..
    When i go to IW33(Order Details) i cannot see the notification, instead notification field is found to be blank.
    Although i can see the notification linked in Object tab, but for reporting purpose i want the notification on header level.
    I am using BAPI_ALM_ORDER_MAINTAIN for order creation. Passing all the values from SAP-MII. (integration with ECC)
    Appreciate any help on this.
    Thanks
    Shashank

    Hi
    It seems that you are creating both notification and order as part of your enhancement. Because, if you make the settings for automatic creation of the notification, which will use the standard functionality, when you save the work order, notification will be created automatically and attached to the work order header.
    The setting is called "Define Notification and Order Integration"
    You must link the order with the notification type and select "Maintain Indicator for Notification Data on Order Header" box.
    I hope this will help
    Cheers

  • SAP MII to SAP ME integration using MEINT component

    Hello Experts,
    I am currently studying the integration part between ERP and ME using ME INT component. I am done with configuration necessary for meint in MII. I am quite clear with workflow from ERP to MII using IDoc. But workflow from MII to ME is confusing me a lot. So please help me on this issue.
    Target: BOM data has to be transfered from ERP to ME.
    Understanding till now:
    1. ERP will send a BOM (via IDoc) to MII.
    2. MII will send it to a queue in ME INT database.
    Queries:
    1. After an IDoc is added to MEINT message queue, how will it be passed to ME?
    2. Also, if I send BOM data to ME before ITEMs are configured in ME, will ME through an error?
    I have gone through "SAP MEINT Overview and data communication between SAP ECC and SAP ME via SAP MEINT" help documentation but I didnt get enough clarity over sending data to ME.
    Your reply will be appreciated.
    Thanks.
    Regards,
    Minakshi.

    Hello Minakshi,  See my comments in blue.
    Understanding till now:
    1. ERP will send a BOM (via IDoc) to MII.
    2. MII will send it to a queue in ME INT database. ( This one is not quite right )
    Inbound Integration :
    ECC sends IDOC .
    MII receives IDOC and process using message processing rule ( not MEINT Database )
    Uses WS calls internally to insert data into ME (WIP Databse)
    Outbound integration:
    ME adds a record in MEINT table with input xml  ( MEINT workflows are used in the background )
    MII processes those records from MEINT tables in batches based on the configuration.
    Hope this helps.
    Thanks
    Hari

  • Seimens HMI Integration with SAP MII

    Dear MII Experts,
    We are trying to integrate shop floor systems with SAP MII for discrete manufacturing industry.
    I came across the client has 70+ machines in the plant .the vendor is "DMG"
    Seimens HMI is installed on each machine .
    What are the possible ways here to connect to PLC from MII
    I am very new to this integration part .
    Can MII directly connect to Seimens HMI .
    I am very new to this area , client is ready to pay extra cost for any extra interfaces .
    Please suggest me the architecture to follow .
    Please give me a detailed explanation here , please correct me if I my explanation is wrong here
    Please reply me for any other clarification

    Hi Eswaraiah,
       To access the PLC data in MII, you would need couple of things more.
    1. OPC Server where the PLC stores the data.
    2. PCo (SAP Plant Connectivity) that can read the data from OPC Server and send the data to MII for manipulation.
    From PCo MII can read the data and you can then perform your business logic. Also, PCo has built-in notification settings which can trigger MII's transactions based upon some conditions.
    So I believe, your landscape would look like
    Siemens HMI --> OPC Server  -> PCo --> MII
    Check these out...
    PLC Integration with SAP MII
    Connecting MII to PLC devices
    Communicating with PLC
    Regards
    Tufale Ashai

  • MII -- MES Integration

    Hi,
    We have a situation where MES System is Integrated to Shopfloor devices such as Sensor's, PLC's and HMI's and they have the Database where they gone a save the captured data and MII needs to read that data and capture them in dashboards, till here I am able to understand but how the data flow will be if ERP is sending the downstream data to MES and then MES sends the confirmations to ERP, I mean how database can be used in such scenario.
    Thanks,
    Raveen

    Hi ,
    Which MES you are using in your shopfloor.if it is SAP ME then we will store data in WIP database which is SAP ME database then you can send to SAP or get it from SAP.
    Thanks,
    Ramesh

  • NWDI Integration to MII sca files

    Hi,
    Iam trying to integrate NWDI with existing MII. Iam using MII 12.1.8 version.
    I have downloaded MII_BUILDT.sca SP08, and XMII.sca SP08 patches from servive marketplace.
    Where can I get the SAP_BUILDT.sca file. Also for integration where should all these 3 sca files to be placed(i mean which path).
    Please advice.
    Thanks,
    Padma

    Hi Manoj,
    Thanks for the path to find the sca file.
    But now I am confused which SP version of this file has to be downloaded whether I need to take MII SP version or NW SP version?
    According to MII project building and deploying it says this path \usr\sap\trans\EPS\in\CMS<server><sid>\CMS\inbox  for deploying these files is this is correct?
    Also one more thing while configuring Integration of MII with Existing NWDI in MII nwa I closed the browser directly , now I see  start , resume , re-execute all three buttons are disabled. how can I start or re-execute .
    Any help would be appriciated
    Thanks,
    Padma
    Edited by: Rao on Jul 7, 2011 9:28 AM

  • MII Minitab Integration

    Hello,
    I am trying to use the minitab integration features in MII. I was wondering if anyone has used this feature, if so could they give some example transactions. I can get the data output in minitab format using the minitab action block but am hoping that it's possible to replace my display template with a minitab chart on my web page. Is this possible?
    Any help is appreciated, thanks.

    Hi, Nick.  I have done Minitab integration with MII (I wrote the Minitab interface for MII), but it was a LOOOONG time ago, so I don't remember the specifics.  I do remember that it was very possible to have Minitab activated by clicking on a link on an MII web page, with dynamic data being sent to Minitab from an MII BLS transaction.  I just don't recall the exact details of how to structure the URL.  I suspect it involved putting a fake filename on the end of the URL that included a file extension that Minitab knew how to open.

  • MII transaction as Web service integration

    Hi MII's transaction can be called as WS but it has its own format. We have a system to integrate and this system should call MII's transaction. However the WS interface of the system is inflexible (it cannot be change, but has a very simple structure). So I just want to know any idea how we could change MII in order to adapt to the data structure .

    Now, I am able to create the Web Service in SAP and it is now showing the respective class, attribute and methods to execute this web service (web service to call MII transaction).
    But when I am calling it from ABAP (a simple Web Dynpro for ABAP method), it is showing me the following error:
    Error (id=GET_BUSINESS_SYSTEM_ERROR): An error occurred when determining the business system (LD_ERROR)
    Thought this error is coming from ABAP program, but I am sure that this is related to some configuration at SAP level. (Let me inform you that there are two different servers for SAP Web Dynpro ABAP and SAP MII.
    Please help.
    Thanks in advance.

  • PCo integration with MII and MES

    Hi,
    How is PCo placed in MII and ME Achitecture. Can PCo directly connects to Shopl floor systems? and how it is connected to MES system. IS this something like Shop floor>PCo->MII->ME->ERP?
    Can someone please make me understand?
    Thanks,
    Raveen

    Hi,
    as per my knowledge MII helps to interface between MES (if it is installed) and ERP.
    if we consider levels then
    all the PLCs are in level 1.
    all the scada,Historian are in level 2,
    MES and database in level 3,
    and ERP in level 4.
    MII is between level 3 and level 4,
    it helps to interface this two level.
    as I know PCO can configured with MII. PCO help to create that connectivity between the tag value coming from the scada historian system and MII.
    regards,
    Suman

  • MII WinCC integration

    Dear all,
    We want to get current and historical data from WinCC.
    We have MII server.
    We have also WinCC server. WinCC OPC server is installed on WinCC servers.
    There is firewall between WinCC and MII servers.
    We installed UDS on MII server.
    Questions:
    1) Shoul we install UDS on MII server or WinCC server? If both is possible, which one is effective?
    2) Can we read real time and historical data by only using OPC server adn UDS, without installing 'WinCC connectivity pack".
    Why should I use this connectivity pack, if they use OPC standarts?
    Kind regards,
    Hamza.

    Hamza,
    1.  It is always better if you can to install the UDS on the same machine as the OPC Server you are connecting to.  This is more efficent as it will cause less traffic over http.  Also sometimes problem occur with DCOM issues and since this would be a local install, this would be alleviated.  But if not allowed then it can be installed with the MII server or even on a seperate Windows box.  Note the UDS is Windows based so it must be installed on a Windows OS.
    2.  I am not familiar with this and would have to test in order to see if it is needed.  Unfortunately we do not have a WinCC system to test this against.  From reading some of the documentation it seems like this may be needed to get the OPC HDA access if needed.

  • Single Sign ON in MII 12.0

    Hi All,
    Is single sign on possile from MII 12.0 to SAP ECC 6.0
    I know for EP and MII but not sure of ECC and MII and how
    Any clues?
    Thanks & Regards
    Namita

    Hi,
    SAP WEB GUI -> Web based user interface was released at the end of 1996.This was the time when R/3 3.1G was released along with Internet Transaction Server.
    WebGUI is still an excellent interface to SAP.
    SAP GUI-> With the ITS integrated in the SAP Web Application Server, the Web browser
    communicates directly with the SAP system. This is in contrast to the standalone ITS,
    where the AGate acts as a SAP GUI logging on to the SAP System.
    To know more details you go through the following link:
    http://help.sap.com/bp_epv260/EP_JA/documentation/How-to_Guides/WAS/Enabling%20the%20SAP%20GUI%20for%20HTML%20with%20the%20integrated%20ITS%20on%20SAP.pdf
    Hope this will help you.
    Thanks,
    Manisha

Maybe you are looking for

  • Setting up a mail account

    I have a webmail account which I want to set up on 'mail' on my ipad2. I have instructions from the webmail site on how to do this, and I have followed it to the letter. When I try to access it on the 'mail' app I receive a message saying 'Cannot get

  • I have doubt ltrim

    hi i have requirement i need to ltrim('xof_flexfield','xof') so that it give the 'flexfield' but it is giving as 'lexfield' is any other way to do my requirement to get flexfield thnak in advance..

  • Boot Camp Error - Erased Partition?

    I erased windows partition as instructed, finished my work and restarted the computer... it opens up in windows. I search, and discover my OSX partition has been erased. All my files were on there, university work, music, photographs! Is there any wa

  • Nautilus bookmarks - drag and drop - gnome 3

    Hi in gnome 2 nautilus I could add folder from right pane to the left as a shortcut (or what was the name for that). In gnome 3 all my shortcuts are there, now called bookmarks. Only thing is that now I can't drag and drop files from right pane to th

  • Suddenly, iTunes doesn't open, and crashes machine

    Hello chaps, I've been running iTunes on my Vista PC for a year or so with no problems at all. Last night, for no apparant reason (I hadn't installed any new software etc.), it broke. When I tried to run iTunes, it didn't open, and my PC hung - forci