Webgui was not called due to an error

Error as Below
==============
Error when processing your request
What has happened?
The URL http://server01.mydomain.com:8005/sap/bc/gui/sap/its/webgui was not called due to an error.
Note
The following error text was processed in the system Q61 : System error
The error occurred on the application server server01_Q61_05 and in the work process 3 .
The termination type was: ABORT_MESSAGE_STATE
The ABAP call stack was:
      SYSTEM-EXIT of program SAPLSMTR_NAVIGATION
What can I do?
If the termination type was RABAX_STATE, then you can find more information on the cause of the termination in the system Q61 in transaction ST22.
If the termination type was ABORT_MESSAGE_STATE, then you can find more information on the cause of the termination on the application server server01_Q61_05 in transaction SM21.
If the termination type was ERROR_MESSAGE_STATE, then you can search for more information in the trace file for the work process 3 in transaction ST11 on the application server server01_Q61_05 . In some situations, you may also need to analyze the trace files of other work processes.
If you do not yet have a user ID, contact your system administrator.
Error code: ICF-IE-http -c: 999 -u: P0000XXXX -l: E -s: Q61 -i: server01_Q61_05 -w: 3 -d: 20080612 -t: 132603 -v: ABORT_MESSAGE_STATE -e: System error
HTTP 500 - Internal Server Error
Your SAP Internet Communication Framework Team
================
What is the solution ??
================
PR

Hi,
You can check [note 816973|https://service.sap.com/sap/support/notes/816973] which gives details on problem analysis with ITS as well as the steps to follow to get it working.
Regards,
Nelis

Similar Messages

  • /sap/bc/webdynpro/sap/ags_workcenter was not called due to an error

    Hi,
    I get the following error when I click on Exception Analysis for one of our managed system.
    Solution Manager Diagnostics -> End to End Analysis -> Select the Managed system and click on Exception Analysis
    The URL http://kressapcrm.in.kres.keane.com:8000/sap/bc/webdynpro/sap/ags_workcenter was not called due to an error.
    Note
    The following error text was processed in the system SOL : Exception condition "COMMUNICATION_ERROR" raised.
    The error occurred on the application server KRESSAPCRM_SOL_00 and in the work process 0 .
    The termination type was: RABAX_STATE
    The ABAP call stack was:
    Method: EXECUTE of program CL_IGS_CHART_ENGINE===========CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/CBUSINESS_GRAPHICS======CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C7STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C7STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    If the termination type was RABAX_STATE, then you can find more information on the cause of the termination in the system SOL in transaction ST22.
    If the termination type was ABORT_MESSAGE_STATE, then you can find more information on the cause of the termination on the application server KRESSAPCRM_SOL_00 in transaction SM21.
    If the termination type was ERROR_MESSAGE_STATE, then you can search for more information in the trace file for the work process 0 in transaction ST11 on the application server KRESSAPCRM_SOL_00 . In some situations, you may also need to analyze the trace files of other work processes.
    If you do not yet have a user ID, contact your system administrator.
    Error code: ICF-IE-http -c: 999 -u: E2E_ADMIN -l: E -s: SOL -i: KRESSAPCRM_SOL_00 -w: 0 -d: 20100107 -t: 164340 -v: RABAX_STATE -e: RAISE_EXCEPTION
    Regards
    Shailaja

    >
    shailaja stalin wrote:
    > (...)
    > The URL http://kressapcrm.in.kres.keane.com:8000/sap/bc/webdynpro/sap/ags_workcenter was not called due to an error.
    > Note
    >
    > The following error text was processed in the system SOL : Exception condition "COMMUNICATION_ERROR" raised.
    > The error occurred on the application server KRESSAPCRM_SOL_00 and in the work process 0 .
    > The termination type was: RABAX_STATE
    > The ABAP call stack was:
    > Method: EXECUTE of program CL_IGS_CHART_ENGINE===========CP
    > Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/CBUSINESS_GRAPHICS======CP
    > Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    > (...)
    Please check the configuration and version of the IGS.
    Regards,
    Ruediger

  • BSP Error:bc/bsp/sap/crm_bsp_frame/mainDH.do was not called due to an error

    Dear All,
    i am working on CRM 5.0 Netweaver-2004S-SR2, facing below errror.
    Error when processing your request
    What has happened?
    The URL http://hllsap44.in.u1609.unilever.com:1080/sap/bc/bsp/sap/crm_bsp_frame/mainDH.do was not called due to an error.
    Note
         The following error text was processed in the system CD2 : The current application triggered a termination with a short dump.
         The error occurred on the application server hllsap44_CD2_00 and in the work process 0 .
         The termination type was: RABAX_STATE
         The ABAP call stack was:
    Method: BUILD_MODEL of program CL_CRM_BSP_ACCS_MODEL=========CP
    Method: CONSTRUCTOR of program CL_CRM_BSP_ACCS_MODEL=========CP
    Method: GET_MODEL_INSTANCE of program CL_CRM_BSP_ACCS_MODEL=========CP
    Method: SET_APPLICATION of program CL_CRM_BSP_IL=================CP
    Method: DO_INIT of program CL_CRM_BSP_FRAME_MAIN=========CP
    Method: DO_INIT of program CL_BSP_CTRL_ADAPTER===========CP
    Method: GET_PAGE_CONTEXT_CURRENT of program CL_BSP_CONTEXT================CP
    Method: ON_REQUEST_ENTER of program CL_BSP_RUNTIME================CP
    Method: ON_REQUEST of program CL_BSP_RUNTIME================CP
    Method: IF_HTTP_EXTENSION~HANDLE_REQUEST of program CL_HTTP_EXT_BSP===============CP
    Soon reply will be appreciated.
    thanks,'
    Thakkar.

    thanks For prompt attention towards my problem..
    DUMP: Runtime Errors         MESSAGE_TYPE_X
    Details:
    What happened?
        The current application program detected a situation which really
        should not occur. Therefore, a termination with a short dump was
        triggered on purpose by the key word MESSAGE (type X).
    What can you do?
        Note down which actions and inputs caused the error.
        To process the problem further, contact you SAP system
        administrator.
        Using Transaction ST22 for ABAP Dump Analysis, you can look
        at and manage termination messages, and you can also
        keep them for a long time.
    Error analysis
        Short text of error message:
        Model for application set CRMD_CASE has been maintained inconsistently
        Long text of error message:
         Diagnosis
             After including the referenced application in the application set,
             at least one structure name is no longer unique.
         System Response
             An inconsistent model leads to termination.
         Procedure
             Contact your system administrator.
         Procedure for System Administration
              IMG -> Customer Relationship Management -> Layout of User
             Interface (People-Centric UI) -> Application Element-> Application
             Set.
        Technical information about the message:
        Message class....... "CRM_BSP_BLUEPRINT_DB"
        Number.............. 010
        Variable 1.......... "CRMD_CASE"
        Variable 2.......... " "
        Variable 3.......... " "
        Variable 4.......... " "
    thanks,
    Rakesh.

  • URL webdynpro was not called due to an error after integration

    Hi All,
    I have integrated SRM (ABAP) to EP(dual-stack) portal system (both are EHP1) which are freshly integrated using BS: SRM-Portal (Basic Configuration) V1.
    I've checked SRM web based GUI "http://<hostname>.<FQCN>:8002/sap/bc/gui/sap /its/webgui"
    and it's working, but when i tried to check webdynpro,
    "http://<hostname>:<FQCN>:8002/sap/bc/webdynp ro", i couldn't connect to the link. I already read this sap note "1088717 - Active services for Web Dynpro ABAP in transaction SICF" and compared all services in SRM (ABAP) that should be activated but this error still persists. I already changed this parameter icm/host_name_full and SAPLOCALHOSTFULL.
    Error in accessing webdynpro link:
    Note
    The following error text was processed in the system SR2 : WebDynpro Exception: Application // Does Not Exist
    The error occurred on the application server MDCSAP05_SR2_02 and in the work process 0 .
    The termination type was: RABAX_STATE
    The ABAP call stack was:
    Method: RAISE of program CX_WD_GENERAL=================CP
    Method: IF_WDR_RUNTIME~GET_RR_APPLICATION of program CL_WDR_MAIN_TASK==============CP
    Method: CREATE_APPLICATION of program CL_WDR_CLIENT_ABSTRACT_HTTP===CP
    Method: IF_HTTP_EXTENSION~HANDLE_REQUEST of program CL_WDR_MAIN_TASK==============CP
    Method: EXECUTE_REQUEST of program CL_HTTP_SERVER================CP
    Function: HTTP_DISPATCH_REQUEST of program SAPLHTTP_RUNTIME
    Module: %_HTTP_START of program SAPMHTTP
    Any solution for this? Please help thanks!
    Best regards,
    Tony

    Hi,
    If you called this URL : "http://<FQDN>:<port>/sap/bc/webdynpro"
    The error is normal : you tried to call the webdynpro runtime without telling which webdunpro application you want.
    A real webdynpro URL looks like : http://<FQDN>:<port>/sap/bc/webdynpro/application
    Regards,
    Olivier

  • BSPWDApplication.do was not called due to an error

    Hi,
    In CRM Web UI, under IC_AGENT BP role, in "Inbox" when i click on any email to view it, i am getting the below error,
    The following error text was processed in the system BCQ : Exception condition "NOT_FOUND" raised.
    The error occurred on the application server CRSQW01_BCQ_00 and in the work process 1 .
    The termination type was: RABAX_STATE
    The ABAP call stack was:
    Method: GET_MAIL_DATA_FROM_SO of program CL_CRM_EMAIL_UTILITY_BASE=====CP
    Method: CREATE_BOL_OBJECT_SC of program CL_IC_MAIL_WRAPPER_SC=========CP
    Method: GET_AC_PROXY of program CL_CRM_AUI_WORKITEM===========CP
    Method: BUTTONS of program CL_CRM_AUI_WORKITEM===========CP
    Method: CHECK_SELECTION of program CL_ICCMP_IN_INBOXITEMS_IMPL===CP
    Method: SET_MODELS of program CL_ICCMP_IN_INBOXITEMS_IMPL===CP
    Method: DO_REQUEST of program CL_BSP_WD_VIEW_CONTROLLER=====CP
    Method: DO_REQUEST of program CL_BSP_CTRL_ADAPTER===========CP
    Method: CALL_CONTROLLER of program CL_BSP_PAGE_BASE==============CP
    Method: IF_BSP_ELEMENT~DO_AT_END of program CL_BSP_CALL_ELEMENT===========CP
    Also it is giving an ABAP dump, RAISE_EXCEPTION - Exception condition "NOT_FOUND" raised.
    On further analysis, i found that the problem exists in Method "GET_MAIL_DATA_FROM_SO" of program "CL_CRM_EMAIL_UTILITY_BASE=====CP". as soon as we execute the above method it is throwing the NOT FOUND exception.
    I am not an Abaper, can anyone help me out to resolve this issue.
    I tried but could not find any notes on this error.
    Regards,
    Siva.

    Hi,
    You can once consult with your development team who can give you clear idea on this.
    Also you can get development experts' opinion posting it in ABAP forum.
    Regards,
    Sujit.

  • Error : URL not called due to an error

    Hi All,
             I developed a Web Dynpro ABAp application and tested it through a user with SAP_ALL Profile, and am getting the following error message:
    The URL http://sileccdev053.simondelhi.com:8000/sap/bc/webdynpro/sap/zadobe was not called due to an error.
    Note
    The following error text was processed in the system DEV : WebDynpro Exception:
    The error occurred on the application server SILECCDEV053_DEV_00 and in the work process 0 .
    The termination type was: RABAX_STATE
    The ABAP call stack was:
    Method: CONSTRUCTOR of program CL_WD_ADOBE_SERVICES==========CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/CADOBE==================CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/CADOBE==================CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C8STANDARD==============CP
    Method: IF_NW7_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program /1WDA/C7STANDARD==============CP
    Method: IF_WDR_VIEW_ELEMENT_ADAPTER~SET_CONTENT of program CL_WDR_VIEW_ADAPTER===========CP
    Method: IF_WDR_NW7_DELTA_RENDERER~CALCULATE_DELTA_BLOCKS of program CL_WDR_VIEW_ADAPTER===========CP
    Method: IF_WDR_NW7_DELTA_RENDERER~CALCULATE_DELTA_BLOCKS of program CL_WDR_WINDOW_CONTENT_ADAPTER=CP
    Method: SET_CONTENT of program CL_WDR_NW7_INT_WIN_ADAPTER====CP
    What can I do?
    If the termination type was RABAX_STATE, then you can find more information on the cause of the termination in the system DEV in transaction ST22.
    If the termination type was ABORT_MESSAGE_STATE, then you can find more information on the cause of the termination on the application server SILECCDEV053_DEV_00 in transaction SM21.
    If the termination type was ERROR_MESSAGE_STATE, then you can search for more information in the trace file for the work process 0 in transaction ST11 on the application server SILECCDEV053_DEV_00 . In some situations, you may also need to analyze the trace files of other work processes.
    If you do not yet have a user ID, contact your system administrator.
    Error code: ICF-IE-http -c: 300 -u: PWCABAP -l: E -s: DEV -i: SILECCDEV053_DEV_00 -w: 0 -d: 20110215 -t: 111729 -v: RABAX_STATE -e: UNCAUGHT_EXCEPTION
    HTTP 500 - Internal Server Error
    Your SAP Internet Communication Framework Team
    In ST22 we get the following:
    WHAT HAPPENED:
    The exception 'CX_WD_GENERAL' was raised, but it was not caught anywhere along
    the call hierarchy.
    Since exceptions represent error situations and this error was not
    adequately responded to, the running ABAP program
      'CL_WD_ADOBE_SERVICES==========CP' has to be
    terminated.
    ERROR ANALYSIS:
    Error analysis
        An exception occurred which is explained in detail below.
        The exception, which is assigned to class 'CX_WD_GENERAL', was not caught and
        therefore caused a runtime error.
        The reason for the exception is:
        WebDynpro Exception:
        The occurrence of the exception is closely related to the occurrence of
        a previous exception "CX_FP_API_REPOSITORY", which was raised in the program
         "CL_FP_WB_HELPER===============CP",
        specifically in line 7 of the (include) program
         "CL_FP_WB_HELPER===============CM00V".
        The cause of the exception was:
        Object ZADOBE does not exist
    Please Suggest something.
    Cheers!!!
    Umang

    Hi Umnag,
    I think this application is using any Adobe Form and there is any issue wth the form interface.
    Please check syntax of the Adobe form as well as Form Interface. The Interface methods are throwing some exception which is not handled in the CL_WD_ADOBE_SERVICES.
    You can put a break-point in the costructor of above class and pin-point the issue yourself.
    Hope this helps!
    Reagrds
    Vineet

  • Itunes update would not install due to an error, now itunes won't run and I get this message when I try to launch itunes: "This application has failed to start because MSVCR80.dll was not found. Re-installing the application may fix this problem"

    itunes update would not install due to an error, now itunes won't run and I get this error message when I try to launch itunes: iTunes.exe - Unable to Locate Component "This application has failed to start because MSVCR80.dll was not found. Re-installing the application may fix this problem."
    I'm on a Dell PC running Vista Home Premium.
    HELP!!!!!!!!!!!!!!!!!!!

    try removing all itunes and all other apple program
    follow this link for more info. http://support.apple.com/kb/HT1923
    reboot ur window after uninstalling
    after that download the latest itunes setup and install.

  • F-53 Error- u201C Item was not activated due to on line payment block.u201D

    When we are doing payment document against T Code F-53 for FI document  systems is giving message
    That u201C Item was not activated due to on line payment block.u201D
    This error is due to what ?
    Regards,
    Shekhar Gaikwad

    Hi,
    Kindly release your invoice document in MRBR..
    Then proceed further.
    revert if any issues.
    Utsav

  • Breakpoint was not set due to a generation error

    Hi,
    I have this problem, there is a transaction that doesn’t execute in the productive environment, BUT the transaction can be executed in quality and DEV environment.
    So when I set a breakpoint (in productive), this message come up “Breakpoint was not set due to a generation error for ZCO_AllTheJazz_DETAIL” (the program).
    The Question is: WHAT does it means and HOW can I fix it?
    Any suggestions are welcome
    Ubadawan

    Ok sorry max I didn't think that the name was important.
    The name is ZCO_OBJECT_CO_DETAIL
    The message number is ED057 and its main program is SAPLSHL2.
    Im going to explain some more, when I execute the transaction a screen with the syntax error (like you said Rob) said:
    The following syntax error occurred in the program ZCO_OBJECT_CO_DETEAIL. "Field 'G_GLOBAL_OBJECT-HIEART' is unknown"
    The thing is, I checked and is declared on
    INCLUDE ZCO_OBJECT_CO_DETAIL_top.
    Like this -> data: G_GLOBAL_OBJECT type kkb_global_object.
    This means that it is declared.
    I’m starting to think: this two errors are related.

  • TS3694 sirmy iphone 3G was not on due to software update and its not resotre previous software and shown as error 1051 kindly resolve my issue as soon as possible

    sir my iphone 3G was not on due to software update and its not resotre previous software and shown as error 1051 kindly resolve my issue as soon as possible

    The easiest way to fix the hosts file is to restore it from a backup that predates the modification, or to copy the unmodified file from another Mac. If you can't do that, then do as below.
    Triple-click anywhere in the line below on this page to select it:
    open -e /etc/hosts
    Copy the selected text to the Clipboard by pressing the key combination command-C.
    Paste into a Terminal window by pressing command-V. A TextEdit window should open. At the top of the window, you should see this:
    # Host Database
    # localhost is used to configure the loopback interface
    # when the system is booting.  Do not change this entry.
    127.0.0.1                              localhost
    255.255.255.255          broadcasthost
    ::1                                        localhost
    Below that, you may see some other lines. The first 9 lines should be exactly as above, apart from differences in the blank space within lines. Otherwise you can't use this procedure—STOP and ask for guidance.
    If the contents of the TextEdit window are as described, close it, then enter the following command in the Terminal window in the same way as before (by copy and paste):
    sudo sed -i~ '10,$d' /etc/hosts
    You may be prompted for your login password, which won't be displayed when you type it. Type carefully and then press return. If you don’t have a login password, you’ll need to set one before you can run the command. You may get a one-time warning to be careful. Confirm. Quit Terminal.
    If you see a message that your username "is not in the sudoers file," then you're not logged in as an administrator. Log in as one and start over.
    That will fix the hosts file. There is now a copy of the old hosts file with the name "hosts~" in the same folder as "hosts". You can delete the copy if you wish. Don't delete the file named "hosts".

  • LABVIEW.LIB was not called from a LabVIEW process

    Hi All,
    I've inherited LV code that calls a CIN node to access a motor controller.  I'd like to compile this code to a .NET DLL, but receive the following error when calling it from an external source:
    I've read the knowledgebase article explaining the problem from here, as well as the following support questions:
    http://forums.ni.com/t5/LabVIEW/Labview-lib-was-not-called-from-a-labview-process/m-p/232548
    http://forums.ni.com/t5/LabVIEW/Problem-with-lsb-LABVIEW-LIB-was-not-called-from-a-LabVIEW/m-p/48809...
    http://forums.ni.com/t5/LabVIEW/Labview-lib-was-not-calld-from-a-labview-process/m-p/718427
    http://forums.ni.com/t5/LabVIEW/Building-a-LabVIEW-DLL-with-VIs-that-use-CINs/m-p/632817
    The conclusion seems to be recompiling is the answer.  I've tried recompiling the original CIN vi within LV with no success.  Do they mean to recompile the original C code against the newer labview.lib (sorry, I'm not all that familiar with how the CIN nodes work)?  Any suggestions would be awesome.  Thanks.
    -Joe

    You can't make use of LabVIEW manager functions in non-LabVIEW based processes. Basically unless the C code is for a CIN or DLL that is to be called by LabVIEW (inside the development system or a LabVIEW built application), any function pulled in from labview.lib is not available. LabVIEW.lib is an import library that does not implement any functions but simply imports them from the LabVIEW kernel, either the LabVIEW development system or the LabVIEW runtime DLL. And no you can't just link in the LabVIEW runtime DLL into your .Net application. This DLL needs to be started up and initialized in very specific ways, that only LabVIEW itself knows about when building an application.
    Basically if you want to recompile the code (yes in C/C++) for use in a non-LabVIEW application, you also have to remove all the link libraries from the LAbVIEW cintools directory, and replace any use of functions now unavailable (link error: unavailable external reference) with other similar functionality from your C runtime library. Or implement those functions yourself using C runtime library calls.
    Another possibility could be to actually create a LabVIEW executable that exports the functionality as ActiveX Server. Or in LabVIEW 2010 you could also select to create a .Net Interop Assembly from inside the LabVIEW project.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • LABVIEW.LIB was not called from a LabVIEW process when creating unit tests

    We are developing a DLL to be integrated in LabVIEW using CLFs. So far we have the system working, but we wanted to create some unit tests in C as part of our release process. The problem is that when I link labview.lib in VS C++ and then call the EXE generated I get an error saying: "LABVIEW.LIB was not called from a LabVIEW process". As mentioned in http://zone.ni.com/reference/en-XX/help/371361J-01/lvexcodeconcepts/debug_dlls_and_dll_calls/:
    "Calling the shared library from another C program is also another way to debug the shared library. By calling the shared library from another C program, you have a means of testing the shared library independent of LabVIEW, thus helping you to identify any problems, sooner."
    Some of our functions, however, use LabVIEW specific instructions and we would like to test them in a realistic environment (i.e., calling to the actual functions instead of creating stubs).
    Is there any workaround to this problem?
    Thanks!!

    Hello SaraGr,
    Welcome to the NI Discussion Forums! I have a couple of questions to better determine the issue here:
    1. What is the LabVIEW version that you are using?
    2. Does your DLL uses Serial Compatibility VIs? If so, try using your development on NI-VISA instead of Serial.
    3. Are you using a Code Interface Node (CIN)? If you do, I see that from the help file you would need to compile the code for the new platform. Also, please remember that functions specifc to CINs (such as SetCINArraySize) will not work in a DLL.
    4. Be sure to include the header files in your program, like extcode.h. Please follow this white paper to link labview.lib to your program, or follow the Alternate Method.
    Regards,
    Daniel REDS
    RF Systems Engineer
    Help us grow.
    If a post solves your question, mark it as The Solution.
    If a post helps, give Kudos to it.

  • The disk you inserted was not readable By this computer (Error)

    Hi
    everytime in the last couple of days im inserting a bank Cd to my cd/dvd drive (MATSHITADVD-R UJ-85J) im getting the same error
    "the disk you inserted was not readable By this computer"
    it only happen when the disk is blank. all other disks work ok.
    haven't install any new software or hardware, but had some HDD problems.
    any suggestion what should i do?
    my system profile is:
    version 10.5.7
    Hardware Overview:
    Model Name: iMac
    Model Identifier: iMac7,1
    Processor Name: Intel Core 2 Duo
    Processor Speed: 2.4 GHz
    Number Of Processors: 1
    Total Number Of Cores: 2
    L2 Cache: 4 MB
    Memory: 2 GB
    Bus Speed: 800 MHz
    Boot ROM Version: IM71.007A.B03
    SMC Version (system): 1.20f4
    Serial Number (system): W873226** <Edited by Host>

    first time posting so not sure this ended up in correct area...
    I had same issue except only repairing the permissions didn't solve anything for me. *_If you recently upgraded your iTunes to 8.2_* check your permissions for errors, fix the errors, then restart computer and if that doesn't fix it, then try one of the 3 solutions below as there is a *known burn issue with the recent 8.2 update!*
    My permission errors - permissions differ on ./Applications/iTunes.app/contents... etc, should be -rw-rw-r--, they are -rwxrwxr-x
    I called Apple Care and we figured out 3 work arounds til a fix is released.
    Solutions 1,2 are recommended by Apple Care. I used solutions 1 (easy) and then 3 (complicated).
    Option 3 is a pain and takes A LOT of time and HD space or external HD if you have tons of music, podcasts, audiobooks, etc, loaded into your iTunes.
    _*3 possible solutions:*_
    1. Use the Finder window already built in the mac (to burn onto blank cds) -
    Open Finder Window, go to File in the Menu Bar at top of computer, create a new Burn Folder, drag items to the folder and click on the burn icon inside the folder, insert blank disk when asked, add name, select burn speed, burn the cd.
    2. Use the app Burn 2.3U -
    Found at Apple.com in download section works like a Finder Window and converts audo files to MP3 automatically. (You can set up iTunes to do this as well)
    3. Install an older version of iTunes 8.0.2 (couldn't find 8.1 thru 8.1.051) -
    I found 8.0.2 at Apple.com, this process is complicated and you will need lots of HD space or external HD to do this because you'll want to back up your music library and you will need to delete version 8.2 BEFORE trying to install an older version. Otherwise stick with option 1 or 2 til a fix is released by Apple.
    I ruined 8 blank cd's that actually burned but then I got the error message "the disk you inserted was not readable by this computer (Error)" at end of burn cycle and sometimes early disk ejections. _*I had no problems before the iTunes update in the past 5 days.*_ Still can't read/play the 8 disks but the problem went away!
    I had burned 20 cds no problem last week with same media disks that were producing errors after doing the iTunes update, now after chosing to downgrade my iTunes I'm back to burning with no issues!
    8.2 has 2 versions 32bit or 64bit, one of them may be PC/Windows version only but not sure which one I upgraded to or if that's even a factor with the permission errors I had.
    Best wishes

  • Unable to install iTunes after converting from Windows Vista to Windows 7.  Am told installation was successful, then "iTunes was not installed correctly", followed by "Error 7 (Windows error 193).

    Unable to install iTunes after converting from Windows Vista to Windows 7.  Am told installation was successful, then "iTunes was not installed correctly", followed by "Error 7 (Windows error 193).  I have my iPod plugged into my computer via USB port.  What am I doing wrong?

    i have the only account on my laptop so have checked and am the account administrator
    i run windows 7 home premium
    I have the same problem and
    have followed the link uninstalling in the correct order,
    then restarted as per instructions,
    went to Apple to download itunes,
    hit download now,
    Visit the iTunes download page. Click Download Now to download the iTunes installer. When prompted, click Save (instead of Run).
    did not get a save instead of run prompt
    Right click on iTunesSetup or iTunes64Setup (the installer you downloaded in step 3).
    If you have Windows Vista, Windows 7, and Windows 8: Choose "Run as administrator."
    i can only click run as administrator from right clicking the shortcut on my desktop screen
    If iTunes fails to install or repair, it might be necessary to remove components left from a previous installation of iTunes and then reinstall.
    sick of doing this
    at least 7 or 8 times i have re installed itunes to no avail
    troubleshooting no better
    please help. pulling my hair out at this stage
    it was working fine until 2 days ago when i opened itunes it offered to update to 12.1
    not working since i clicked yes
    also i have gone to restore previous point and ffs there are no restore points before my multiple reinstalls
    really dont want to have to restore factory settings

  • It will not open & I get "...plc4.dll was not found..." error message

    It will not open & I get "...plc4.dll was not found..." error message

    Do a clean reinstall and download a fresh Firefox copy from http://www.mozilla.com/firefox/all.html and save the file to the desktop.<br />
    Uninstall your current Firefox version and remove the Firefox program folder before installing that copy of the Firefox installer.<br />
    It is important to delete the Firefox program folder to remove all the files and make sure that there are no problems with files that were leftover after uninstalling.<br />
    You can skip the step to create a new profile, that is not necessary for this issue.
    See http://kb.mozillazine.org/Standard_diagnostic_-_Firefox#Clean_reinstall
    Do a malware check with a few malware scan programs.<br />
    You need to use all programs because each detects different malware.<br />
    Make sure that you update each program to get the latest version of the database.<br />
    *http://www.malwarebytes.org/mbam.php - Malwarebytes' Anti-Malware
    *http://www.superantispyware.com/ - SuperAntispyware
    *http://www.safer-networking.org/en/index.html - Spybot Search & Destroy
    *http://www.lavasoft.com/products/ad_aware_free.php - Ad-Aware Free
    *http://www.microsoft.com/windows/products/winfamily/defender/default.mspx - Windows Defender: Home Page
    See also "Spyware on Windows": http://kb.mozillazine.org/Popups_not_blocked and [[Searches are redirected to another site]]

Maybe you are looking for

  • ABAP runtime error for Field Symbel.

    Dear Friends, I am getting the ABAP runtime error while moving the value to field symbol, the field value is currency . I have downloaded the data from Excel sheet into an internal table and finaly when I am passing the data to a field symbol I am ge

  • Find Out Image Mode, Profile and RES

    HI I have 5 Files in one folder 3 images are CMYK, 2 images are RGB when i run the script i want to output for (.Html OR  Alert in photoshop) Filename |      Profile         | Resolution abb.tif      | North America | 72 dpi

  • Upgrade DB2 database from 9.1 to 10.5

    Dear All, We are using Ecc6 with db2 database 9.1 now we want to upgrade database from 9.1 to 10.5. Is it possible to upgrade database & what are those steps are required for this operation. We are waiting your valuable support in this regards. Regar

  • 10.2.0.4 ------ 11.2.0.2   upgrade

    Hi, We are performing the upgrade from 10.2.0.4 to 11.2.0.2 database I have run the pre upgrade script and have envountered the following error. I have tried all possible ways given in google to solve the issue but the issue seems to be still existin

  • Hide Sidecar files appearing after upgrade?

    How do you hide Sidecar files NOW appearing in NEF photo folder on desktop after Yosemite upgrade? In Adobe Bridge, you have option to hide sidecar files. Can't find a way to hide them from view in OS Finder folders.