Weblogic Monitoring with SCOM 2012

Hello,
I need to monitor WebLogic 10.3 installed on Windows Server 2008 SP2 so I added these MP :
Microsoft.JEE.WebLogic.Library.mp
Microsoft.JEE.WebLogic.10gR3.mp
Microsoft.JEE.Library.mpb
Microsoft.JEE.Templates.Library.mpb
And I created a specific basic account (with administrator application rights) that I linked to the JEE Monitoring Account Profile.
I checked in the Event Viewer and I got : Event 1109 - All credential references resolved successfully.
But when I can't see anything in the Weblogic Application Servers specific views. And in the Heath Explorer of my server I have this :
For information, I don't get any error in the event viewer about this.
Can someone help ? Thanks.

1) What is the exact version of WebLogic that you're installing? 
WebLogic Server Version: 10.3.0.0
2) In the WebLogic installation root, there is a registry.xml file. What is the version
listed for the Xpath: /bea-product-information/host/product/release?
<release level="10.3" ServicePackLevel="0" PatchLevel="0" Status="installed" BeaProgramGroup="Oracle WebLogic" StartMenu="C:\Documents and Settings\All Users\Start Menu\Programs"
InstallTime="Oct 17, 2008 5:10:52 PM" InstallDir="D:\bea10.3" JavaHome="D:\bea10.3\jdk160_05" JavaVersion="1.6.0_05" JavaVendor="Sun">
3) In the domain, is there a domain-registry.xml?  If so, what are its contents?
In the domain, domain-registry.xml is missing.
4) Are there managed servers on that WebLogic domain & the same machine?  If
so, have they been discovered?
Yes there is a managed server on that Weblogic domain on the same machine, no it hasn't been
discovered.
5)
What do you mean by "There is no monitoring of Weblogic admin servers". Here the monitoring needs of our application admin :
connections per application
Weblogic server status (running / problem /other)
JVM Memory
6) You mentioned that you enabled unit monitors, can you clarify specifically which unit monitors you enabled? 
7) Have you tried the PowerShell script yet & did that work?
Not yet. I will try.

Similar Messages

  • Dell server hardware component monitoring with scom 2012 R2.

    hello ..
    We have some dell poweredge r710 SFF 2X SIX CORE X5 SAS Servers ,I need to monitor its hardware components with scom2012 R2.I have installed os:windows server hyper-v server on this and windows server core OS management packs on scom and monitoring
    working fine  .next I want to know their is Latest Management pack available for this  dell model server and what are hardware components can be monitored with scom 2012 R 2. I want to monitor Hardware failure such as   Power failure ,cpu failure,disk
    failure and NIC failure etc
    Thanks
    Richa

    Hi,
    Please refer to the User’s Guide of the DELL MP:
    http://support.dell.com/support/edocs/software/smconect/msscom/40/en/ug/pdf/Dell_Server_Management_Pack_Suite_v4.0_UG.pdf
    Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Meanwhile, considering this is related to DELL products, if you need more information or further investigation, please also contact DELL support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Exchange 2010 and 2013 Monitoring with SCOM 2012

    HI all,
    I have exchange 2013 and 2010 in my environment , Iwant monitor both in SCOM 2012,
    Can you all please tell can i implement 2013 monitorinng first later can i go to 2010 Monitoring, Please advise in that supported or do i need to go with exchange 2010 monitoring first

    There are no dependencies on the 2010 MP so you should be good to go, see the following:

  • Bulk URL Monitoring is SCOM 2012 SP1

    Hey Team,
    i need to setup 100 + url monitors in scom 2012 sp1, i came across a term named BULK URL Monitor which suits my requirement. The issue is i am failing to get it to work when i click Bulkmonitor.exe i am gettign the below error and not sure how to resolve
    it.
    System.IO.FileNotFoundException: Could not load file or assembly 'Microsoft.EnterpriseManagement.Core, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.
    File name: 'Microsoft.EnterpriseManagement.Core, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35'
       at Microsoft.EnterpriseManagement.BulkUrlManager.BulkUrlManagerForm..ctor()
       at Microsoft.EnterpriseManagement.BulkUrlManager.Program.Main()
    WRN: Assembly binding logging is turned OFF.
    To enable assembly bind failure logging, set the registry value [HKLM\Software\Microsoft\Fusion!EnableLog] (DWORD) to 1.
    Note: There is some performance penalty associated with assembly bind failure logging.
    To turn this feature off, remove the registry value [HKLM\Software\Microsoft\Fusion!EnableLog].
    Any suggestions will be highly appreciated.
    -vrkumar01
    RajKumar

    It worked.
    intially i tried to install in \System Center 2012\Operations Manager\Setup & System Center 2012\Operations Manager\Server both failed but this
    System Center 2012\Operations Manager\Console worked.
    thanks a lot
    -vrkumar01
    RajKumar

  • Windows Azure Monitoring in SCOM 2012 R2

    Hi,
    We have Azure subscription which has few cloud services and VM in running state. We want to monitor the VMs running on Azure using SCOM 2012 R2 running on our corp network behind firewall. SCOM Server connected to the internet through the corp proxy.
    We have imported the Azure Management packs in to SCOM and Added the Subscription successfully. But, the Azure resource inventory like Discovered Cloud Services, Discovered Storage, Discovered Virtual Machines are empty.
    Kindly please help to configure azure monitoring using SCOM 2012 R2.
    Thanks
    Kumaresan Lakshmanan

    Hi 
    SCOM monitoring check data in azure store, check if the events and performace data is transferring to the azure store.if data is not transfering for event id counters monitor fail to work . 
    refer below link for more information
    Implementing Windows Azure
    Diagnostics (http://go.microsoft.com/fwlink/?LinkId=186765).
    Transferring Diagnostic
    Data to Windows Azure Storage (http://go.microsoft.com/fwlink/?LinkId=191347). 
    Regards
    sridhar v

  • OEM integration with SCOM 2012

    Hi, 
    Can anyone help me out on the topic- OEM integration with SCOM 2012.

    Are you refer to this document
    Oracle® Enterprise Manager Installation and Configuration Guide for Microsoft System Center Operations Manager Connector
    http://docs.oracle.com/cd/E24628_01/install.121/e28572.pdf
    Roger

  • Issues with Monitoring Azure services with SCOM 2012 R2

    Hi,
    I'm trying to setup monitoring of our Azure subscriptions in a new installation of Operations Manager 2012 R2 which is running in-house as it is also monitoring our internal services.  I've used the guide below:
    http://blogs.msdn.com/b/walterm/archive/2013/04/13/first-impressions-on-system-center-management-pack-for-windows-azure-fabric-preview-for-scom-2012-sp1.aspx
    This has all worked OK and I've been able to add the subscription into OP Manager and it's found the cloud service, storage and VM's.  However when I try to add the monitoring and I go to create this When I select the Add option in the Add Monitoring
    Wizard and click the Search button to list the components (Cloud Service, Storage and VM's) nothing is found despite me having already selected the subscription.
    Has anyone else experienced this or can offer any advice?
    Many Thanks
    Colin

    Hi,
    Which version of RDP client you are using for your client?
    Does more user login at same period of time?
    As you have commented that after sticking the user can’t able to login in RDCB server, here I can suggest you to check the setting of connection broker. Also you can check that you have place the proper location path of UPD while configuring in collection configuration
    wizard. You can take a look at below article foe virtual desktop configuration.
    Deploying Virtual Desktops with Windows Server 2012
    Are you trying to use same UPD for different collection then also it might happens to occur your issue. The fact of UPD is User profile disks are for a single collection only. A user connecting to two different collections will have two separate profiles. If
    you want to synchronize settings, refer to Microsoft User Experience Virtualization. Go through this article for more understanding related to UPD.
    Working with User Profile Disks on Session-Based Desktop Deployments
    Hope it helps!
    Thanks.

  • Monitoring services on MSMQ cluster with SCOM 2012

    Hello guys,
    I'm looking a way that SCOM 2012 is able to monitor several services installed on MSMQ cluster. I think it's possible that SCOM 2012 can generate alert through the message queuing service associated to these services but this is an indirect monitoring. I
    would want that SCOM generates the alert for the specific service in problem.
    Any suggestion?
    Thank you very much.

    Hi,
    There is a management pack for ​Message Queuing.
    You can download it from http://www.microsoft.com/en-us/download/details.aspx?id=36775
    Hope it help's
    Greetings,
    Roel Knippen
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • Performance of Network Monitoring in SCOM 2012 SP1

    Hi all!
    I´ve problems with performance of the network monitoring feature in SCOM 2012 SP1.
    According to the
    guide the following should be adeqate:
    •1000 network devices (approximately 12,500 monitored ports) managed by a resource pool that has three or more management servers
    •500 network devices (approximately 6,250 monitored ports) managed by a resource pool that has two or more gateway servers
    We have 800 network devices with a total of 24000 ports,
    BUT only 1500 of them are monitored. This is basically what happens automatically after discovery, since only ports between monitored devices are monitored by default.
    For this setup I first used only one management server dedicated to the Network Pool,
    based on my assumption that if two servers could monitor 6250 ports, one server would be more than enough for 1500. I found this configuration working very poorly so I added another server. I now have two servers
    dedicated for the Network Resource Pool. (They are NOT members of the “All management servers resource pool”)
    Still, I get constant alerts regarding Health Services Private Bytes on these servers. They vary between 1-2Gbytes. Furthermore, if one of the servers goes offline, the network devices that was monitored by that server becomes grey for
    several hours. Even if the server only is rebooted it takes forever to get everything online and green again.
    I don´t really know what I should do now. I had a plan to replace our current network monitoring system (SNMPc) which easily handles this load on only one server. They are of course completely different beasts, but still. SCOM seems to
    require a massive back-end to produce equivalent real life results.
    Any suggestions or reflections from the field are highly appreciated!
    Regards
    Peter

    Hi,
    Try to overide the monitor Health Services Private Bytes by the following steps.
    ◾Go Authoring space – Management Pack Objects – Monitors
    ◾Go to change scope – select clear all – look for Health Service – tick it and press OK.
    ◾Expand Health Service – expand Entity Health – expand Performance – expand Health Service Performance
    ◾Select the Health Health Service Private Bytes Threshold.
    ◾Right click the mouse and choose to overide the monitor for a group
    ◾Select the group called Management Server Computer Group and press OK
    ◾Select the Agent Performance Monitor Type – Threshold and change the value 104857600 to ex. 2610612736.
    ◾Select to store the overide in a management pack you have created and press OK
    Juke Chou
    TechNet Community Support

  • General hardware monitoring on SCOM 2012 R2

    Hello everybody. Sorry for maybe common question, i'm absolutely newbie in SCOM. I'm standing at task of monitoring basic servers counters - Memory utilization, disk free space & CPU utilization. After reading some articles about SCOM architecture I
    get a little frustrated - cannot get full understanding about monitoring mechanisms. What I want from my monitors:
    - Monitor 2,3...N groups of servers with _different_ disk free space thresholds and sending alerts (email) to specific people.
    I've already have imported management pack for Windows OS, configure channels & subscribers.
    I get a lot of question trying to configure such monitoring, maybe you can help me (or send me to manuals)
    1. I can use monitor's for specific OS (i.e. logical disk free space), then I need to override it(why? I can't use it?) and select servers.
    2. How can I map a group of servers to monitor?
    3. Do I need rules?
    4. New monitor sets in installed agents automatically?
    Cannot understand steps, in which I should resolve my task..

    1. Windows OS management pack has default monitor for disk free space and CPU utilization. If you 2,3,...N groups of servers with different disk free space thresholds, you should create Groups which contains the required servers and using override with target
    of the gorups.
    For how to create an override, pls. refer
    http://jimmoldenhauer.blogspot.hk/2012/11/scom-2012-creating-overides.html
    2. The target of the monitor is set to the groups of server
    3. It depend on situation
    Rules do not affect the health state of the target object. They are used for one of three functions
    a) Alerting Rules
    Alerting rules create an alert when a particular event is detected. This can be any of the different kinds of events shown in Data Sources. Alerting rules do not affect health state.
    b) Collection Rules
    Collection rules collect events or performance data to the Operations Manager database and data warehouse. They do not create alerts or set health state.
    Collection rules can use each of the data sources shown in Data Sources. The data will be converted to either an event or to performance data depending on the particular kind of collection rule you are creating. For some wizards, you will need to provide
    the specific information from the data source that will be used for different properties of the data being collected.
    c) Command Rules
    Command rules will run a script or command on a schedule. They do not create alerts or collect any data.
    4) All agents will automatic download updated its monitor and rule which applicable to the server.
    Roger

  • Minimum value of UNIX/Linux Heartbeat Monitor in scom 2012

    Hi,
    In my environment, we have SCOM 2012 server, when I change values of UNIX/Linux
    Heartbeat Monitor: Interval , Missed
    Heartbeats and Missed Heartbeats from 300 , 630 ,2 to 120, 150, 1 in event viewer shows Error
    11112:
    The Microsoft Operations Manager Consolidate Module failed to initialize because the specified compare count is less than the minimum
    Compare count value : 1
    Minimum value allowed : 2
    One or more workflows were affected by this.
    What is the best minimum value?
    Thanks

    You've ended up in the wrong forum. mostly service manager here, Ops manager is
    over there https://social.technet.microsoft.com/Forums/en-US/home?category=systemcenteroperationsmanager. 
    That being said, the error you reference is somewhat abstracted from the values you adjusted. the error you posted is the system comparison operator complaining that it only has one thing to compare, typically you need two things to do a comparison.
    Here is a person running into a similar problem with the lync MP, where it was trying to compare the site assignment of two systems, but the environment only has one system.
    http://thoughtsonopsmgr.blogspot.com/2014/09/lync-server-2010-mp-bug-alert.html. is it possible this is an outgrowth of something similar in your unix environment? Do you have any more details about the specific health XML that's failing?

  • Benefits of Client Side Monitoring with SCOM 2012R2?

    I'm working on the architecture for adding SCOM 2012R2 to our Windows network.  Right now we use SCCM 2012R2 and SCEP.  I'm trying to determine whether I should include our workstation computers as part of this or only servers.  We won't
    be doing Application Performance Monitoring (APM).  So what would be the benefit of putting the SCOM agent on the workstations?
    # When I wrote this script only God and I knew what I was doing. # Now, only God Knows!

    Hi,
    As it was mentioned by Yan Li_ first thing to do is the proper planning and comparing all pros and cons of SCOM client monitoring, depending on numbers of agent\agentless servers\workstations to be monitored. With a large number of agentless monitored
    clients, it makes sense to have a separate SCOM infrastructure.
    As well, please look at this links:
    http://stefanroth.net/2013/05/27/scom-agentless-exception-monitoring-aem-faq/
    http://stefanroth.net/2013/05/14/scom-2012-custom-aem-reports/
    http://www.ms-opsmgr.eu/?p=332
    Natalya
    ### If my post helped you, please take a moment to Vote as Helpful and\or Mark as an Answer

  • Services monitored by SCOM 2012

    Hi All,
    I am using SCOM 2012 SP1 in our environment. I am a bit puzzled about what all services of a windows server are monitored by default in SCOM. I am asking this because recently we have WinRM service stopped on a windows server but no alert get generated in
    SCOM. Does I need to manually set up monitoring for this service?
    Regards,
    Daya

    Hi,
    The System Center Management Pack for Windows Server Operating System provides the fundamental monitoring basics for computers.
    From what I can see, the WinRM service is not monitorred by default.
    And I would like to suggest you also download the MP guide for Operating System management pack to get more details:
    http://www.microsoft.com/en-hk/download/details.aspx?id=9296
    Regards,
    Yan Li
    Regards, Yan Li

  • EM 12C Integration with SCOM 2012

    Hi
    Has anyone integrated EM12C ( running on Solaris Sparc ) with MS SCOM 2012 ? Just looking for any hints / tips /issues ... etc ...
    Any thoughts appreciated.
    Regards
    Rob

    If the integration is along the lines of forwarding events from Enterprise Manager 12c to SCOM, then we are currently finalizing an event connector for SCOM 2012. It will enable the sending of events from Enterprise Manager to SCOM.
    Regards,
    Ana

  • How to enable default disabled linux monitor on scom 2012 r2

    hello,
    I have scom 2012 r2 environment and i have imported 'SCOM 2012 R2 MP linux and Unix '.then installed agent on one of linux redhat6 machine.it got installed successfully but next how to get data in following highlighted portion except these am getting data
    in all the portion.

    To enable disabled rule,you can run below script by write MP name and class that you want to enable it
    $MP
    = Get-SCOMManagementPack
    -displayname "Managment pack name"
    | `
    where {$_.Sealed
    -eq $False}
    $Class
    = Get-SCOMClass
    -DisplayName "rule name"
    $Rule
    = Get-SCOMRule
    -DisplayName "*Events/sec"
    Enable-SCOMRule -Class
    $Class -Rule
    $Rule -ManagementPack
    $MP -Enforce
    For more details, you can refer below link
    http://www.systemcentercentral.com/opsmgr-2012-disabling-rules-and-monitors-in-bulk-in-powershell/
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

Maybe you are looking for

  • New Emails not in Bold

    I use Verizon/Yahaoo email and most of my new emails are not arriving in my inbox in bold.  New emails are unbolded or as if I've already read them.  I have a Firewall and I have changed my password twice in the last few days and still I have this pr

  • Powerbook as a DVD player

    I want to know what cables and adapters I need to buy in order to connect my popwerbook to my TV. I searched the apple web page but the ones shown, does not seem to work with powerbooks. This is my first mac, I would really appreciate some help. Than

  • ABAP application and "End User License"

    Hi all, I'm happy to join to SDN!!! I newbe in the forum, and therefore I don't know if I post in the right section. I'm a Netweaver Architect and ABAP Developer. In the past I worked as java developer, and with other programming languages. I have a

  • .class and .jar

    Hi every one, In a research lab that i'm working, we're developing a big software. Eventually we are trying to make it destributed. Our problem is that every time we try to send our updated code to the our clients, we send the library in .jar. Bad th

  • Handling forwarding errors