Webrfc,Webreporting,ITS flow Logic  Settings

Hello All,
I have a query regarding configuration settings for Webrfc,webreporting and ITS flowlogic applications with standalone ITS and EP.Can anyone please tell me what configuratuon settings are required on EP for all the above three applications to be operating?
Can these applications be run on the integrated ITS without any performance issues?
Please help.
Thanks ,
Deepti.

Hello Deepti
webrfc, webreporting (xgateway=sapgwfc) and ITS flowlogic (xgateway=sapxginet) are based on RFC communication. These services are not supported by the Integrated ITS.
For those you need to install and use the standalone ITS 6.20 version. With that the EP setup should be the same as with all other IACs and EWTs.
best regards
Gerd

Similar Messages

  • How do I confirm ITS flow logic  exists?

    Hi Guys,
    We are upgrading from R/3 4.6C to ECC6.0. The old ITS 2 applications one on ITS 6.2 and another ITS 2.0.
    We are having difficulty in finding out/confirming if there is a ITS flow logic involved in the stand alone ITS. This will tell us what kind of effort is needed. I have gone thru forums where they have very good info on how to migrate and what needs to be done if one has flow logic.
    My question I do not know if there is ITS flow logic OR how do I confirm if ITS flow logic was involved in the development. What do I need to look at? I looked at <flow> kind of searches in HTML pages...not found...I looked at the ".flow" files...not found.
    Since I do not have this background, would appreciate if anyone can point me in the rigth direction...maybe I missed some good documents on SDN?
    Any inputs appreciated.
    regards,
    Anand

    Hi Edgar,
    I did look at the .srvc file and one of them has sapxginet against the line for ~xgateway, along with other params.
    This is one step closer. Thanks for this info.
    Is there any other place like a HTML side or otherwise where the ITS flow logic will also be evident. My next step is to see to what degree it has been used.
    regards,
    Anand

  • ITS Flow Logic : Example of passing a Fields/tables from Function Module?

    Hi all,
    does someone know, what needs to be done (including settings) to being able to call a FM with various outputs(fileds and tables) from a flow file !?
    I am a little bit confused...a full example would be greatly appreciated !!
    Thank you very much !
    Chris

    this may be of help to you.
    http://www.sapgenie.com/its/flowlogic.htm
    Regards
    Raja

  • Calling a Page(flow logic ) from a controller

    Hi Guru's ,
        I have a senario in which I have a controller and also Page flow logic .. I want to call a page of type page flow logic from the controller ..
    I tried the below methods .. but it didnt work ..
    *navigation->goto_page('test.htm').
    DATA: r_view TYPE REF TO if_bsp_page.
    DISPATCH_INPUT( ).
    r_view = create_view( view_name = 'test.htm' ).
    call_view( r_view ).
    this works only if its is a view but not flow logic ..
    Please give ur suggesions ..
    Thanks
    Sivaraj

    hi sivaraj ,
    first refer whether u could call a page using pages with flow logic by the controller which is used in mvc design.
    may be u canot call it . u have to create a page using view according to mvc . try it once.

  • Reg: UTA ports FCoE, 10GbE flow control settings

    Could someone shed some light on the flow control settings for UTA ports, below is the scenario.I am working on  the configutation of 4 node 3220 custer. We are using this 4 node cluster for FC and NFS traffic. each UTA port on the node used to serve both FcoE and NFS traffic( UTA port logically acting as FC and 10GbE ports) . However, the flow control is set to FULL on the 10GbE logical port to serve  the NFS traffic. I think this flow control settings at 10GbE logical port level doesn't effect the FC traffic flow of the UTA port. the flow control settings would be effective on 10GE logical ports only.. Please confirm this... NetApp recommend to set the flow control to NONE and upper layer protocalls can take care of flow control( as per Best practise). If I want to change the flow control setting of 10GbE logical port, does it effect the data flow of logical FC0E port aswell?Now the actual issues is we are using the controllers mostly to serve FC trafic and we are experienceing Performance issues on all the nodes. current ONTAP version on the controller is 8.2p5we are hitting the latency of 50-80ms, I am trying to track the IO on the controllers, IO is not really high when we had the performace issues, But some times disk utilizations and cpu utlization hitting 80%. Performace manager doesn't have the granularity at aggregate level to track what LUN/volumes are casuing the high utlization at aggregate level..I am using the coomands sysstat -M, sysstat -x, netstat , statit commands mainly. However, I am not sure on any other internal porcesses are causing the high disk uitlizations...Please share your ideas on this..Oh.. another point this.. These controllers are flexpod config.....

    Hi,We haven't worked on flow control settings.. you mean you are able to Disable the flow control on CNA cards?We have upgraded these filers to 8.2.3P3. at the moment filers are working fine, no performance issues.. However I wanted to disable the flow control on these ports, if possble. But NetApp docs tell that we cann't disable the flow control on the CNA cards.   https://library.netapp.com/ecmdocs/ECMP1368834/html/GUID-31241255-4914-46FF-BDB5-A02DCCEABCCA.html  Regards,Chandra 

  • In MVC, do i need a View or Page with flow logic for POPUP window

    Hi All,
    I have the below scenario using the MVC pattern.
    I have a main view with 3 trays, each tray has two buttons, for example first tray has Create Order button. When I click on this button, I need a popup window to come with a tableview and a button(Create), where I select some rows and click on the button Create  to create order.
    But as per the MVC pattern I canu2019t call the view (popup) from another view(main view).  So should I create a VIEW or PAGE WITH FLOW LOGIC for the popup? .
    I need 6 popup to be called from the main view and once the function is done close the popup.
    Please suggest me the flow for this scenario.
    Cheers,
    Srini.

    Srini,
    1. You can call the view in pop-up because you will be calling the controller using open.window.
    Here is the sample code:
    method DO_REQUEST .
      data:
            li_vw           type ref to   if_bsp_page,
            lv_form_field   type          string,
            li_md           type ref to   zcl_model01.
      dispatch_input( ).
      li_md ?= get_model( 'm01' ).
      lv_form_field = request->get_form_field( 'invoice_create' ).
      if lv_form_field is initial.
    *------ Request to display main page
        li_vw = create_view( view_name = 'main.htm' ).
        li_vw->set_attribute( name = 'model' value = li_md ).
        call_view( li_vw ).
      elseif lv_form_field eq 'true'.
    *------ Request to display Invoice page in pop-up
        li_vw = create_view( view_name = 'invoice.htm' ).
        li_vw->set_attribute( name = 'model' value = li_md ).
        call_view( li_vw ).
      endif.
    endmethod.
    Layout:
          function do_Invoice()
          { var s=0; r=1; w=300; h=300; x=screen.width/2;
            x=x-w/2;
            var y=screen.height/4;
            y=y-h/2;
            popUp=window.open('main.do?invoice_create=true','win','width='+ w
            +',height='+ h +', left=' + x +',top='+ y +');
    Option2:
    Ofcourse you can't bind the model in page becos those are 2 different things. But all you need to do is access the model to get some value. To know how to access the model from Page w/flow logic look at [this link|Passing model reference to a page in a Popup].
    Raja
    Edited by: Raja Thangamani on Apr 14, 2009 11:22 AM

  • RPM_FIN02 - Receiver of IDoc is its own logical system

    For one particular portfolio item, I run the RPM program RPM_FIN02.
    This results in an IDoc creation.
    Next, I checked the status of the IDoc (RPM > Base System Interfaces > SAP Financial and Controlling Integration > Data Distribution From SAP FI-CO to SAP xRPM > Check Inbound Processing).
    This shows the status "29 - Receiver of IDoc is its own logical system".
    As a result, the Internal Order costs (including the ones posted from cProjects) do not get pulled into RPM Financial Planning.
    Please advise.
    I do not have the technical understanding of this issue, and would therefore need a little more than the mere technical jargons and terms to be able to resolve this.
    Thanks for understanding.

    Hi,
    Very briefly,
    -Assuming your RPM system is independent of your ECC box. But RFC connected.
    -RPM_FIN02 is for pulling in financial data onto RPM item from (object linked) Internal Order(IO)/PS Project(PSP).
    -RPM_FIN02 do not recognize/goto cProjects for financials.
    -cProjects can have its own account assigned IO/PSP
    -cProjects Dashboard, (if all is well incl. evaluation) should display costs from assigned IO/PSP
    -This cost does not reach RPM item
    -Source of cProjects- if it is created within cProjects or from RPM Item, does not matter.
    thanks,Mathavan

  • IDOC error - Receiver of IDoc is its own logical system

    hi,
    i have a requiremnt to generate the IDOC for the same and same client. actually i have to get the data from application server and i have to generate the IDOC.
    for this i have created a Zreport and passed the data from application server to segment and i called the
    FM "MASTER_IDOC_DISTRIBUTE". after executing the Zreport, IDOC is generated and show the error
    status as 29.i.e. Receiver of IDoc is its own logical system.
    my logic is as follows.
    MOVE 'LS' TO w_edidc-rcvprt.
    MOVE 'SBECLNT130' TO w_edidc-rcvprn.
    MOVE 'ISU_MR_UPLOAD' TO w_edidc-mestyp.
    MOVE 'ISU_MR_UPLOAD01' TO w_edidc-idoctp.
    pls let me know the solution for this problem.
    Regards,
    Balu

    Hi  Reddy,
    please let me know how did u solve this issue, even i have the same requirement and am gettign status 29.
    Thanks
    Rakesh

  • ERROR B191 - IDoc has its own logical system as receiver

    I everybody, i'm tryng to execute a package to charge a ODS from another ODS (Datamart) but the process ends with the error "IDoc has its own logical system as receiver", can you help me with is?
    What should be the reason for this error? What can i make to solve it?
    Thanks to all

    Hi  Reddy,
    please let me know how did u solve this issue, even i have the same requirement and am gettign status 29.
    Thanks
    Rakesh

  • Flow Logic jumping to HTML Template (with SAP dialog) & back again

    Hello
    Overview
    ========
    Within a HTML Template that uses flow logic, can I call a HTML Template that has SAP dialog behind it.  The SAP dialog is a function module that has a screen requesting user input and then follows on to display selection based on user input.  The user can then select a value that I would like  returned to the flow logic screens.  Just like an F4 help. 
    Detail
    ======
    This is for SRM (EBP):
    -Internet Service: BBPATTRMAINT
    -Theme: 99
    -HTML Template and flow logic: MAINTAIN_ATTRIBUTES
    Basically I want to give the user more functionality and be able to select addresses using an F4 type scenario.
    The function module I want to call is as follows:
    CALL FUNCTION <b>'F4IF_FIELD_VALUE_REQUEST'</b>
           <b>EXPORTING</b>
                TABNAME           = 'ADRC'
                FIELDNAME         = 'ADDRNUMBER'
                SEARCHHELP        = 'BBP_ADDR_BUPA_BUYER'
                SHLPPARAM         = 'ADDRNUMBER'
                DYNPPROG          = 'BBP_ADDR_MAINTAIN'
                DYNPNR            =  SY-DYNNR
                DYNPROFIELD       = 'BBP_PARTNER_ORG-ADDR_SELECTED'
                CALLBACK_PROGRAM  = 'BBP_ADDR_MAINTAIN'
                CALLBACK_FORM     = 'PRESET_COMPANY_PARTNER'
           <b>TABLES</b>
                RETURN_TAB        = IT_RETVALUES
           <b>EXCEPTIONS</b>
                FIELD_NOT_FOUND   = 1
                NO_HELP_FOR_FIELD = 2
                INCONSISTENT_HELP = 3
                NO_VALUES_FOUND   = 4
                OTHERS            = 5.
    This displays a screen for the user to better define search criteria and follows on to display possible selections.  The user selection is returned in IT_RETVALUES.
    If anyone knows of a similar SAP example where they go from flow logic to HTML templates then that would help a lot.
    Any help or direction would be greatly appreciated.
    Regards
    Peter

    Hey Orcasound, welcome to the forum, and also welcome to Logic.
    Nice setup BTW, especially the Dangerous 2BUS into the BC1 coming back to the Rosetta 800"s, that gonna sound sweet mate.
    OK Q1: The master fader for output 1-2 is always gonna be there, I've never found a way of getting rid of it, you can fortunately set up the mixer so that it won't show though. At the top of the mix window is a heap of boxes highlighted in blue, all you need to do is deselect the master and the output as per this screen shot:
    Save this in your template and you'll never have to see those pesky faders again.
    Q2: Same thing really, logic will always show 1-2 output as stereo out. Which is annoying, even if you manually name them from the I/O labels window it's always stereo, everything else if fine apart from 1-2. To be honest I've just learned to live with it.
    Glad you made the switch, I find DP to be bloated and a bit tired nowadays.

  • Regarding the flow logic in screen painter

    Hi Experts
    I am a BW guy and i am new to ABAP and i need your help to solve my problem.
    I have created a table for master data(zemp_data) in R/3 se11..which has fields like zempid,zempname,zmgrid,zdeptid,zdeptname and i have created the respective fields in screen painter too but my problem is i dont know how to link this fields  in the screen painter to the  fields in table .to be more clear i want the flow logic or module pool code to link this table when i give an entry in the screen painter for the respective  fields..i will really appreciate your answers and award the maximum points for the usefull answer ..as i dont know ABAP much if it is a step by step approach ..that would be helpfull
    Regards,
    RK.

    Hi Karthik,
    Please consider the following
    In the screen...the fields must be from the database table in Se11..(in screen painter -> use.."get from Dictionary" -> enter the table name -> select the fields -> drag and drop on the screen) or must have the same name in the database table..This will be a link but unless you code to fetch values from database or update values to database there will be no action taking place
    Usually in the PBO(process befor output) we write the code to display values before we accept data from the user ie,set default values on the screen if required and prepare the screen for user input
    in the PAI of the screen painter we can do data processing ie, data validations,checks and saving based on what the user wants
    So imagine you have buttons placed on the screen and there are buttons from standard application bar like BACK,SAVE, set using PFstatus..all the user actions will be linked to a function cod..ie whenever user presses a button we can uniquely idntify what was pressed by assigning a function code to each button in the menu painter or PF status and do the action accordingly
    Assume that you have created a push button on the screen painter and assigned it a function code "PUSH"
    so whenever you press the button in the variable sy-ucomm "PUSH" will be captured..this you can check in PAI for the screen like
    Case sy-ucomm.
    when 'PUSH'.
    do the needful coding
    when 'SAVE'
    Modify database table
    endcase.
    you can check the standard demo programs in SE38 -> program name-> display for basic ABAP coding you have asked for
    (1)demo_dynpro_input_output .
    (2)demo_dynpro_dictionary
    (3)demo_dynpro_push_button
    Pls let us know if you need more help on the same
    Reward if helpful
    Regards
    Byju

  • Xhtmlb: tabStrip - how to execut a page with flow logic

    Hello all, how do I execute a "page with flow logic" from a "tabStrip".  Currently I am using a "page fragment".  But I need to change to a "page with flow logic" becuase of a technical issue. 
    Is it possible to tell which tab was selected using event processing?  When I try, I am getting "illegal reference". 
    Here is a sample of my current code.
    <xhtmlb:tabStrip id            = "TABSTRIP"
                     viewState     = "EXPANDED"
                     viewStateMode = "COLLAPSED_EXPANDED"
                     tooltip       = "Choose tab" >
      <xhtmlb:tabStripItem name  = "Home"
                           title = "Home" >
        <%@include file="home.htm" %>
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "Medical"
                           title = "Medical" >
        <%@include file="medical.htm" %> 
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "Dental"
                           title = "Dental" >
        <%@include file="dental.htm" %>
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "Vision"
                           title = "Vision" >
        <%@include file="vision.htm" %>
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "FlxSpnd"
                           title = "Flexible Spending" >
        <%@include file="home.htm" %>
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "Other"
                           title = "Other" >
        <%@include file="home.htm" %>
      </xhtmlb:tabStripItem>
      <xhtmlb:tabStripItem name  = "RevSub"
                           title = "Review and Submit" >
        <%@include file="home.htm" %>
      </xhtmlb:tabStripItem>
    </xhtmlb:tabStrip>
    What would I replace the "page frament" with?
    Thanks in advance for your help, Troy

    Hi Troy,
      If i understood your requirement i think you need to move to other pages or views when the tabstrip items or clicked. If your requirement is the above one below is the explanation....
    In the layout you include a attribute  onSelect        = "mySelect" in the tag  xhtmlb:tabStrip.
    For event handling in the oninputprocessing you write the below code,
       CLASS CL_HTMLB_MANAGER DEFINITION LOAD.
    DATA: TABSTRIP TYPE REF TO CL_XHTMLB_TABSTRIP.
    Reading Data from Toolbar
    TABSTRIP ?= CL_HTMLB_MANAGER=>GET_DATA( REQUEST = REQUEST
                                            NAME    = 'xhtmlb:tabstrip'
                                            ID      = 'tb3' ).
    Optional: test that this is an event from HTMLB library.
    IF EVENT_ID = CL_HTMLB_MANAGER=>EVENT_ID.
    Scenario 1: Read event from manager.
      DATA: EVENT TYPE REF TO IF_HTMLB_DATA.
      EVENT = CL_HTMLB_MANAGER=>GET_EVENT_EX( RUNTIME->SERVER->REQUEST ).
    DATA: request_event TYPE REF TO cl_xhtmlb_event.
    request_event ?= event.
    IF EVENT IS NOT INITIAL AND EVENT->EVENT_NAME =
    CL_XHTMLB_TABSTRIP=>CO_EVENT_NAME.
    *---here you can handle the event... 
    ENDIF.
    ENDIF.
    Regards,
    Azaz Ali.

  • How to call the Page Fragment in Page with Flow logic

    Hi,
        I am new to BSP, My requirement is to created 1 page fragment which contains the Logo.  and to create 2 pages in flow logic
    The  logo has to apper in Pages with flow logic Pages. My question is how to call the PAge fragment in the 1 &2 pagesin page with flow logic
    Thanks,
    suresh

    Suresh,
    There is a very enriching portal help.sap.com  where you can find all basic and good documentation .
    http://help.sap.com/saphelp_nw04/helpdata/en/77/8a54d7434ff34784272a3df98ab645/content.htm
    the above link is from that portal.
    Before asking such basic questions please at least try to find or do some research yourself.
    There are standard applications like HTMLB_SAMPLES and SBSEXT_HTMLB and more for sample applications.
    Regards,
    Anubhav

  • Hpw tp call a 'Page with Flow Logic' from within a View

    Within the same BSP, I have the requirment to call a page in the ;Page with Flow Logic' section from a page in the 'View' section.   
    Is this possible and if it is, how do I do it?  I have tried some calls but they all have failed.
    Thanks
    Glenn

    in the view you want to navigate then try
    <bsp: call > or <bsp: goto>  htmlb tags. or else you can use window.open method and open in a new window.

  • Fill select-options in Page with flow logic ???

    Hello All,
              I created a BSP Application using Page with Flow Logic.
    In the first page of my Application I'm using 2 input fields as select-options.
    Now I'm populating a Ranges of that Field using the type :-
    selopttab
    I populated the ranges table like :-
    wa_bname_sel-sign   = 'I'.
              wa_bname_sel-option = 'BT'.
              wa_bname_sel-low    = '*'.
              wa_bname_sel-high   = 'Z'.
            ELSE.
              wa_bname_sel-sign   = 'I'.
              wa_bname_sel-option = 'EQ'.
              wa_bname_sel-low    = p_bname.
              wa_bname_sel-high   = p_bname.
            ENDIF.
            APPEND wa_bname_sel TO p_bname_sel.
            CLEAR  wa_bname_sel.
    But the problem is I checked the corresponding DATABASE Table entries by passing thesame value .
    i.e I passed the low and high values to the field as '*' and 'Z'.
    The total number of entries differ when passing '*' and 'Z' to when passing SPACE.
    I tried even with contains Pattern .This time the total number of records fetching has Increased but the sum is not exact when passed SPACE to the Database Table.
    So what should I pass to the Low and High values of my Ranges Table to get all the entries ????
    DOes this type of building the Ranges work in BSP's ?
    How are u people working out for the select-options functionality in Page with flow logic ?
    Message was edited by:
            deepu k

    Hello Jessy,
    To populate select-options or Ranges in Page with flow logic I used the following code :
    ************************ Bulid the Select-Options**************************************
          DATA: p_bname_sel     TYPE STANDARD TABLE OF selopttab,
                p_bsp_name_sel  TYPE STANDARD TABLE OF selopttab,
                p_tcode_sel     TYPE STANDARD TABLE OF selopttab.
          DATA: wa_bname_sel    TYPE selopttab,
                wa_bsp_name_sel TYPE selopttab,
                wa_tcode_sel    TYPE selopttab.
    * Select-Options for Username
          REFRESH p_bname_sel.
          CLEAR   wa_bname_sel.
          IF ( p_bname IS INITIAL  ).
            wa_bname_sel-sign   = 'I'.
            wa_bname_sel-option = 'CP'.
            wa_bname_sel-low    = '*'.
            wa_bname_sel-high   = ''.
          ELSE.
            wa_bname_sel-sign   = 'I'.
            wa_bname_sel-option = 'EQ'.
            wa_bname_sel-low    = p_bname.  " p_bname is the Input field and the value is taken from it
            wa_bname_sel-high   = p_bname.
          ENDIF.
          APPEND wa_bname_sel TO p_bname_sel.
          CLEAR  wa_bname_sel.
    * Select-Options for BSP_Application
          REFRESH p_bsp_name_sel.        
          CLEAR   wa_bsp_name_sel.
          IF ( p_bsp_name IS INITIAL  ).
            wa_bsp_name_sel-sign   = 'I'.
            wa_bsp_name_sel-option = 'CP'.
            wa_bsp_name_sel-low    = '*'.
            wa_bsp_name_sel-high   = ''.
          ELSE.
            wa_bsp_name_sel-sign   = 'I'.
            wa_bsp_name_sel-option = 'EQ'.
            wa_bsp_name_sel-low    = p_bsp_name.       " Input field
            wa_bsp_name_sel-high   = p_bsp_name.
          ENDIF.
          APPEND wa_bsp_name_sel TO p_bsp_name_sel.
          CLEAR  wa_bsp_name_sel.
    * Select-Options for TCODE
          REFRESH p_tcode_sel.
          CLEAR   wa_bsp_name_sel.
          IF ( p_tcode IS INITIAL  ).
            wa_tcode_sel-sign   = 'I'.
            wa_tcode_sel-option = 'CP'.
            wa_tcode_sel-low    = '*'.
            wa_tcode_sel-high   = ''.
          ELSE.
            wa_tcode_sel-sign   = 'I'.
            wa_tcode_sel-option = 'EQ'.
            wa_tcode_sel-low    = p_tcode.       " Input field
            wa_tcode_sel-high   = p_tcode.
          ENDIF.
          APPEND wa_tcode_sel TO p_tcode_sel.
          CLEAR  wa_tcode_sel.
    * Select all the related entries when either BSP or TCode is choosen
          IF ( ( p_bsp_name IS NOT INITIAL ) AND ( p_tcode IS INITIAL ) )
                     OR
             ( ( p_bsp_name IS INITIAL ) AND ( p_tcode IS INITIAL ) ).
            REFRESH gt_final.
            SELECT bname
                   bsp_name
                   description
                   ldate
                   ltime
                   calls
                   FROM <custom_table>
                   INTO TABLE gt_final
                   AND   bsp_name  IN p_bsp_name_sel
                   AND   ldate          IN p_ldate_sel.
    endif.
    Hope that wud help u !!!
    Regards,
    Deepu.K

Maybe you are looking for

  • House bank error

    Hi Experts, User is running the APP with the house bank ABCD/L1234, system is taking house bank EFGH/L1234, even if we exclude the house bank EFGH/L1234 the system choose EFGH/L1234 for payment method X. We cheked the payment log " Our bank ABCD is b

  • Currency format and Right Align not working for messagetext in HGrid

    Hi We are dynamically enabling MessageTextinput inside HGrid region, it is Number type and when we set readonly to True it become left align, and currency format also not working, I tried the below various options but nothing is working. Option : 1 O

  • Captivate 4: Never Send Resume Data feature

    I'm new to Captivate 4 and LMS. Want to make sure I understand the use of the LMS Customization Setting - Never Send Resume Data. Should that be deselected or selected in order for the user to be able to "bookmark" or return to the page where they le

  • Repair permissions-deja vu

    I repaired permissions prior to backing up my HD, and 6 items were listed as having been repaired, all having to do with Safari. This was new; I've never seen anything listed as being repaired before. I ran the process again out of curiosity, and the

  • Unable to install Adobe Download Assistant due to the installer being mis-configured

    Download Assistant offers the upgrade from 1.0.6 to 1.2.5, so I "download now" but it won't install because "This application cannot be installed because this installer has been mis-configured. Please contact the application author for assistance." I