What if two service modules fail on a MDS 9513?

Hello,
We recently had a service module failure on one of our core MDS 9513 directors.
It is fixed now but I was wondering what would happen if the second service module had failed as well a bit later...
Will the director still function? All line cards and crossbars are still functionning. But there will be no management possible etc...
Will the traffic continue?
Kind regards,
Ivy

Ivy
The director would then fail completely.
Though I don't know anyone that unlucky

Similar Messages

  • Cisco 3560 service module failed state

    Hi Expert,
    My office has a Cisco 2911 ISR router, we installed a 3560 service module 16P on it.
    But I use command "sh ip int bri" in 2911 router when we finished installation.
    The result shows that the interface Gi 1/1 doesn't work, I have try to re-install SM 16P twice, the result is the same.
    The normal 2911 ISR + 3560 SM 16P show as below,
    2911#sh ip int brief 
    Interface                  IP-Address      OK? Method Status                Protocol
    Embedded-Service-Engine0/0 unassigned      YES NVRAM  administrativelwy down down 
    GigabitEthernet0/0         xxx.xxx.xxx.xxx     YES manual up                    up      
    GigabitEthernet0/1         xxx.xxx.xxx.xxx     YES NVRAM  up                    up      
    GigabitEthernet0/2         unassigned           YES NVRAM  down                  down    
    GigabitEthernet1/0         xxx.xxx.xxx.xxx      YES NVRAM  up                    up      
    GigabitEthernet1/1         unassigned           YES unset  up                    up
    The BAD 2911 ISR + 3560 SM 16P show as below,
    2911#sh ip int brief
    Interface                  IP-Address      OK? Method Status                Protocol
    GigabitEthernet0/0         xxx.xxx.xxx.xxx    YES NVRAM  up                    up
    GigabitEthernet0/1         unassigned          YES NVRAM  administratively down down
    GigabitEthernet0/2         unassigned          YES NVRAM  administratively down down
    GigabitEthernet1/0         unassigned          YES NVRAM  administratively down down

    Hi Krishnendu,
    I understand what you mean, I have done this work for assign Gi 1/0 an IP address, and then using command "service-module gi 1/0 session" to enter the service-module to configure it at all.
    But I just want to know what is the Gi1/1 interface used for?
    I use command "sh cdp nei" on others 2911 ISR + 3560 service module, all of the has the Gi 1/1 interface, and 2911 router using Gi 1/1 interface connected service module Gi 0/17. And Gi 1/1, Gi 0/17 is configured with "trunk interface".
    I'm wondering whether my 2911 router Gi 1/1 has some physics error? or maybe it has another command to to "OPEN" the Gi 1/1 on 2911?
    The "normal" switch display as below,
    rtr001#sh cdp neighbors 
    Capability Codes: R - Router, T - Trans Bridge, B - Source Route Bridge
                      S - Switch, H - Host, I - IGMP, r - Repeater, P - Phone, 
                      D - Remote, C - CVTA, M - Two-port Mac Relay 
    Device ID        Local Intrfce     Holdtme    Capability  Platform  Port ID
    swt000.nneas.net
                     Gig 1/0           129             R S I  SM-ES3G-1 Gig 0/18
    swt000.nneas.net
                     Gig 1/1           129             R S I  SM-ES3G-1 Gig 0/17
    Thanks in advance,
    BR Frank

  • Service Module is failed

    when i show service-module ids-sensor 1/0 status
    i have the following output
    Service Module is Cisco IDS-Sensor1/0
    Service Module supports session via TTY
    Service Module is failed
    Service Module status is not available
    what is the problem and how can i recover it?
    note i make restart for the service module by the command
    service-module ids-snsor 1/0 reset
    but it remain failed
    please help me as soon as possible

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

  • CUE "Service Module is failed"

                       Dears , i am getting this error on CUE .I reload the router but result is same .what should i do now?? ..
    #service-module service-engine 0/1 status
    Service Module is Cisco Service-Engine0/1
    Service Module supports session via TTY line 258
    Service Module is failed
    Service Module status is not available
    Regards,
    Shib

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

  • When I click on Print to print a pdf from my computer, the message "initialization of rasteurization module failed". What does this mean - how do I fix it?

    Why can't I print a pdf in Acrobat Pro? I keep getting the message "initialization of rasteurization module failed". What does that mean and how do I fix that?

    This is an Acrobat error ("Initialization of the rasterizer module failed.") but it is has never been reported before that I can see.
    Let's start with the basics.
    - What version of Acrobat Pro
    - What system
    - What printer
    - Does it happen with other printers?
    - Does it happen with all files?

  • Service-module g2/0 session access fails

    I did not add a vty/telnet password when I initially configured my NME-X-23ES-1G switch in my 3825 router. Now, of course I can not telnet to the switch, but the session access fails as well. How do I recover this?
    Config in 3825:
    interface GigabitEthernet2/0
    ip address 106.40.x.x.255.255.0
    Attempt to access switch module:
    3825_Router2#service-module g2/0 sess
    Trying 106.40.77.254, 2130 ...
    % Connection refused by remote host

    The default configuration for Cisco EtherSwitch service modules allows an end user to recover from a lost password. The password recovery disable feature allows the system administrator to protect access to the switch password by disabling part of this functionality and allowing the user to interrupt the boot process only by agreeing to set the system back to the default configuration. With password recovery disabled, the user can still interrupt the boot process and change the password, but the configuration file (config.text) and the VLAN database file (vlan.dat) are deleted.
    The following document shows how to recover from a lost or forgotten password.
    http://www.cisco.com/en/US/products/hw/modules/ps2797/products_feature_guide09186a0080415bae.html#wp1776357

  • What is the function module to calculate "years of services" in HR?

    What is the function module to calculate "years of services" in HR?

    hi ,
    following function module will help you to find the years of service
    CALL FUNCTION 'HR_HK_TOTAL_YOS' "HR-HK: Calculate an employee's total years of service
      EXPORTING
        years1 =                    " pea_scryy     Years of service
        months1 =                   " pea_scrmm     Months of service
        days1 =                     " pea_scrdd     Days of service
        years2 =                    " pea_scryy     Credit years of service
        months2 =                   " pea_scrmm     Credit months of service
        days2 =                     " pea_scrdd     Credit days of service
      output_format = '01'        " char2         Format to display the output
      IMPORTING
        years =                     " pea_scryy     Total years of service
        months =                    " pea_scrmm     Total months of service
        days =                      " pea_scrdd     Total days of service
        .  "  HR_HK_TOTAL_YOS
    thanks u..

  • What does" connection manager 'invoke' failed to find service connection URL mean

    What does "connection manager 'invoke' failed to find service connection URL" mean

    HOLY CRAP!!!!
    been going round this issues for hours....tried every fix i could find
    phones and most of my pcs worked except 1, my main laptop.
    i FIXED IT BY ENABLING GENIUS.!!!!!!!!!!
    only on that laptop though.
    try it.
    i'm so happy right now.
    not gonna turn it back off again yet cos while its working im not touching it again!

  • What is the usable space of normal redundancy disk group with two uneven capacity fail groups

    Hi,
    I have a normal redundancy disk group (DATA) with two uneven capacity fail groups (FG1 and FG2). FG1 size is 10GB and FG2 size is 100GB.
    In this case what will be the usable space of the disk group (DATA)? is it 10G or 55G?
    Thanks,
    Mahi

    Please, don't duplicate post with same matter.
    This question was answered in your previous thread.
    Re: ASM normal redundancy disk group

  • What permissions require to create CASES (Service Module). Creating new role.

    Hi All,
    Can you please suggest me what permission require to create new case from service module. Steps is below i followed to create case and assigned to user.
    1- Created new blank role.
    2- Went in service module.
    3- Given the Create, Read, Write, Append & Append To permission to CASE entity on organization Level.
    4- Assigned this role to user.
    After assigning this role login into crm online and trying to create case. Its giving message "Insufficient Permission".
    Kindly suggest me the steps i am missing here. Want to assigned single custom created role.
    Thanks in Advance

    Hello,
    Recheck following article -
    http://www.powerobjects.com/blog/2015/02/13/access-denied-identify-fix-security-role-issue/?utm_source=feedburner&utm_medium=feed&utm_campaign=Feed%3A+PowerobjectsMicrosoftCrmBlog+%28PowerObjects+Microsoft+CRM+Blog%29
    Dynamics CRM MVP/ Technical Evangelist at
    SlickData LLC
    My blog

  • Two etherswitch service module in same chassis

    I need to connect two NME-X-23ES-!G in the same chassis (Cisco 3845) and i have the following troubleshooting:
    1.- The numbers of the ports of both cards are identical. They are 1/0/2 to 1/0/24 for both modules. It would not have to change the first number depending on in which slot is inserted the card?
    2.- How I can configure the router for being able to arrive at both modules with the same VLAN. If I configure Etherchannel I cannot configure a IP address for the interface g1/0 or g2/0. If I do not have IP address I cannot make a session to switch module.
    3.- If I use the connect command I cannot use slot number 1 of routers because it leaves a message which not this supported. What I can do for being able to use it?

    Hello,
    I think you need to configure stacking for both modules, here is what CCO says:
    Configuring Stacking
    Stacking is the connection of two switch modules resident in the same chassis so that they behave as a single switch. When a chassis is populated with two switch modules, the user must configure both of them to operate in stacked mode. This is done by selecting one port from each switch module and configuring it to be a stacking partner. The user must then connect with a cable the stacking partners from each switch module to physically stack the switch modules. Any one port in a switch module can be designated as the stacking partner for that switch module.
    Beginning in privileged EXEC mode, follow these steps to configure a pair of ports on two different switch modules as stacking partners.
    SUMMARY STEPS
    1. interface fastethernet interface-id
    2. no shutdown
    3. switchport stacking-partner interface FastEthernet partner-interface-id
    4. exit
    5. interface fastethernet partner-interface-id
    6. no shutdown
    7. end
    HTH,
    GP

  • Active Directory Certificate Services setup failed with the following error: Overlapped I/O operation is in progress. 0x800703e5 (WIN32: 997)

    Hi,
    I am trying to install certificate services on a windows 2008 server (R2 ENT SP1) with a PCIe nCipher HSM module installed on it. The version of nCipher SW is = 11.30.  It is a RootCA, and I am trying to use a key that is already stored in the HSM (I
    have done this before with a PCI HSM (older HW version)).  I select “Use existing private key” and “Select an existing private key on this computer” on the wizard, then i change the CSP to nCipher and click on "search" the key I am looking for
    appears and I select that one.  I repeat, I have done this before and it works with a PCI HSM module.
    The installation is finished before being prompted to insert the operator cards, and it ends with two errors:
    <Error>: Active Directory Certificate Services setup failed with the following error: Overlapped I/O operation is in progress. 0x800703e5 (WIN32: 997)
    And:
    <Error>: Active Directory Certificate Services setup failed with the following error: The group or resource is not in the correct state to perform the requested operation.
    0x8007139f (WIN32: 5023)
    The servermanager.log says:
    1856: 2014-07-23 18:27:48.195 [CAManager]                 Sync: Validity period units: Years
    1856: 2014-07-23 18:27:48.928 [Provider] Error (Id=0) System.Runtime.InteropServices.COMException (0x800703E5): CCertSrvSetup::Install: Overlapped I/O operation is in progress. 0x800703e5 (WIN32: 997)
       at Microsoft.CertificateServices.Setup.Interop.CCertSrvSetupClass.Install()
       at Microsoft.Windows.ServerManager.CertificateServer.CertificateServerRoleProvider.Configure(InstallableFeatureInformation featureInfo, DiscoveryResult discoveryResult, ChangeTracker changeTracker)
    1856: 2014-07-23 18:27:48.928 [Provider]                  CAErrorID: 0, CAErrorString: 'Active Directory Certificate Services setup failed with the following error:  Overlapped I/O operation is in progress.
    0x800703e5 (WIN32: 997)'
    1856: 2014-07-23 18:27:48.928 [Provider]                  Adding error message.
    1856: 2014-07-23 18:27:48.928 [Provider]                  [STAT] For 'Certification Authority':
    And:
    1856: 2014-07-23 18:27:49.053 [CAWebProxyManager]         Sync: Initializing defaults
    1856: 2014-07-23 18:27:49.162 [Provider] Error (Id=0) System.Runtime.InteropServices.COMException (0x8007139F): CCertSrvSetup::Install: The group or resource is not in the correct state to perform the requested operation. 0x8007139f (WIN32: 5023)
       at Microsoft.CertificateServices.Setup.Interop.CCertSrvSetupClass.Install()
       at Microsoft.Windows.ServerManager.CertificateServer.CertificateServerRoleProvider.Configure(InstallableFeatureInformation featureInfo, DiscoveryResult discoveryResult, ChangeTracker changeTracker)
    1856: 2014-07-23 18:27:49.162 [Provider]                  CAErrorID: 0, CAErrorString: 'Active Directory Certificate Services setup failed with the following error:  The group or resource is not in the correct
    state to perform the requested operation. 0x8007139f (WIN32: 5023)'
    1856: 2014-07-23 18:27:49.162 [Provider]                  Adding error message.
    Has anyone experienced this before? Am I missing something here?
    Any help will be very appreciated
    Thanks in advance
    Best regards
    Alejandro Lozano Villanueva

    Hi, thanks for your support.
    I have been playing around a bit with some ncipher commands and found this:
    C:\Program Files (x86)\nCipher\nfast\bin>cspcheck.exe
    cspcheck: fatal error: File key_mscapi_container-1c44b9424a23f6cddc91e8a065241a0
    9aa719e4f (key #1): 0 modules contain the counter (NVRAM file ID 021c44b9424a23f
    6cddc91)
    cspcheck: information: 2 containers and 2 keys found.
    cspcheck: fatal error occurred.
    If I perform the same command on the original server (the server with the original kmdata folder and with the running RootCA services):
    E:\nfast\bin>cspcheck.exe
    cspcheck: information: 2 containers and 2 keys found.
    cspcheck: everything seems to be in order.
    Strange?
    Moreover, when I do a csptest.exe command (also on both servers, i find this)
    On the new server:
    C:\Program Files (x86)\nCipher\nfast\bin>csptest.exe
    nCipher CSP test software
    =========================
    Found the nCipher domestic CSP named 'nCipher Enhanced Cryptographic Provider'
      Provider name: nCipher Enhanced Cryptographic Provider
      Version number: 1.48
    User key containers:
        Container 'csptest.exe' has no stored keys.
        Container 'Administrator' has no stored keys.
      Machine key containers:
        Container '352dd28a-17cb-4c6f-b6e4-bf39bcf75db5' has a 2048-bit signature key.
        Container 'ROOTCA' has no stored keys.
        Container 'csptest.exe' has no stored keys.
    While in the old server:
    E:\nfast\bin>csptest.exe
    nCipher CSP test software
    =========================
    Found the nCipher domestic CSP named 'nCipher Enhanced Cryptographic Provider'
      Provider name: nCipher Enhanced Cryptographic Provider
      Version number: 1.40
    User key containers:
        Container 'csptest.exe' has no stored keys.
      Machine key containers:
        Container '352dd28a-17cb-4c6f-b6e4-bf39bcf75db5' has a 2048-bit signature key.
        Container 'ROOTCA' has a 2048-bit signature key.
        Container 'csptest.exe' has no stored keys.
    As you can see, the container called ROOTCA, which is the one that I use during the installation, says it has no stored keys.  While on the old server, it says it contains a key.  Why is this happening?  I dont know, I am copying the complete
    key management folder from one server to another and initialize the security world with that folder as I always do, and i dont have any errors during this procedure. 
    Do you know what could be the cause of this? or how can I fix this?  Thanks a lot, best regards.
    Alejandro Lozano Villanueva

  • Portal authentication using two login module stacks?

    G'day,
    I am noticing something odd when I authenticate to the portal: there are two login module stacks used.
    Background: I have created a custom logon page, which is basically a form with username/password input as per [this guide|http://help.sap.com/saphelp_nw04/helpdata/en/62/601e1eebf54ca6a97e2873c8c63517/content.htm|Changing the logon screen]. I then modified the authschemes.xml file by defining a new authscheme "mylogon" that uses my own login module stack ("mystack") and uses the new logon page ("mylogonform"). This new authscheme is then made the default reference:
    <authscheme name="mylogon">
      <authentication-template>mystack</authentication-template>
      <priority>21</priority>
      <frontendtype>2</frontendtype>
      <frontendtarget>com.foo.bar.mylogonpage</frontendtarget>
    </authscheme>
    <authscheme-refs>
      <authscheme-ref name="default"><authscheme>mylogon</authscheme></authscheme-ref>
      <authscheme-ref name="UserAdminScheme"><authscheme>mylogon</authscheme></authscheme-ref>
    </authscheme-refs>
    When I want to access the portal, up pops the "mylogonform" page, and on clicking the "submit" button the portal page for the user is shown.
    Now here is the interesting thing: when the "ticket" login module stack is unchanged (ie. it uses the BasicpasswordLoginModule), then the log shows that authentication to the portal uses just my login module.
    This can be seen as follows, where I navigate to the portal, logon as one user, then logoff and logon as another user:
    Message : LOGIN.OK
    User: tu-1
    Authentication Stack: mystack
    Message : LOGOUT.OK
    User: tu-1
    Authentication Stack: mystack
    Message : LOGIN.OK
    User: Administrator
    Authentication Stack: mystack
    The "mylogonform" page is shown when logon is required in both cases.
    However, if I modify the "ticket" login module stack by replacing the BasicPasswordLogonModule with a custom logon module that does automatic authentication, then the following is observed when the "mylogonform" page is displayed:
    Message : LOGIN.FAILED
    User: N/A
    Authentication Stack: ticket
    Message : LOGIN.OK
    User: tu-1
    Authentication Stack: ticket
    For some reason, the modified "ticket" login module stack is now being executed, which was not the case when this login module stack was unmodified.
    This stack automatically authenticates the current user (the initial failure is because the new login module asks the browser to send authentication data), and this "failure" causes the logon form to be displayed.
    I can logon to the portal as the same user, and the logs show that "mystack" login module stack is used:
    Message : LOGIN.OK
    User: tu-1
    Authentication Stack: mystack
    Logoff shows that "mystack" is used for the actual logoff, but "ticket" is called again automatically and succeeds:
    Message : LOGOUT.OK
    User: tu-1
    Authentication Stack: mystack
    Message : LOGIN.FAILED
    User: N/A
    Authentication Stack: ticket
    Message : LOGIN.OK
    User: tu-1
    Authentication Stack: ticket
    (Again, the initial logon failure is the new login module requesting that the browser send authentication data in the next request).
    This brings up the "mylogonform" page, even though it appears that a user has already been authenticated. If I try to logon as another user, the following is shown:
    Message : LOGIN.FAILED
    User: Administrator
    Authentication Stack: mystack
    Login Module                                                            Flag        Initialize  Login      Commit     Abort      Details
    com.sap.security.core.server.jaas.EvaluateTicketLoginModule             SUFFICIENT  ok          exception  false      true       authscheme not sufficient: basicauthentication<mylogonform
    Central Checks                                                                                exception             Call logout before login.
    I guess one cannot authenticate as a new user until the current user has been logged out.
    So ... why does the "ticket" login module get called in the second case, but not in the first case (or only shows logging in the second case) ?
    What is the logic behind portal authentication and showing a logon page?
    If I want to use custom authentication and a custom logon page, why is the "ticket" stack called at all?

    Jayesh,
    there is no such thing like "login module stacks". The <b>do</b> exist on the other hand:
    - login module
    - logon stacks
    Login module and logon stacks are part of the JAAS concept for defining a complex pluggable authentication scheme, original by SUN (see: java.sun.com/products/jaas)
    A logon process is defined by a logon stack which itself consists of several login modules. Each login module performs an authentication step. Example:
    login module 1: check if valid sap logon ticket provided
    if module 1 fails: then login module 2: request user id/password
    if module 2 succeeds: then login module 3: create new sap logon ticket for user
    You can define multiple logon stacks and configure individual applications to use the one stack or the other.
    The logon stack configuration is done using visual administrator. Here select the security provider service for configuring logon stacks.
    btw: As logon stacks are "java-only", there are no transaction names (which only exist on Web AS ABAP).
    Regards,
    Dominik

  • AE CC Render error output module failed

    Hi, I tried my best to find this answer on the forums but couldn't find anything current.
    I have isolated two issues in AE CC where I can duplicate a failed render with this message:
    After Effects error: Rendering error while writing file "xxx". An output module failed. The file may be damaged or corrupted. (-1610153464)
    This happens when opening an AE CS6 project and trying to render a simple comp with only one text layer and a moving mask. It also just happened after my first round trip test with Cinema 4D. I could RAM preview the c4d layer but the output to Quicktime h.264 failed.
    I have even tried a full reinstall of AE CC. I have the basic FxFactory Pro plugins and MagicBullet Looks installed, but neither are being used since this is a single 1280x720 comp with a single C4D layer. Plus like I said it failed with the same error in past CS6 files.
    I don't know how to force disable a plugin to test that, but I can't see how an unused plugin could cause a render to fail like this.
    I'm on a new (late 2012) 27" iMac
    3.4 GHz Intel Core i7
    8GB RAM
    NVIDIA GeForce GTX 680MX with 2GB VRAM
    OS X 10.8.4
    AE CC 12.0.0.404
    CUDA driver 5.0.59
    Thanks for any suggestions!
    Matt

    Olaf, did you read my reply where I explained my solution? First you should try the steps outlined in the article Todd references:
    http://blogs.adobe.com/aftereffects/2011/02/troubleshooting-quicktime- errors-with-after-effects.html
    There seems to be a good way to isolate if it's the same issue I had, though. Let me go into a bit of depth for you.
    The trick was to launch the OS X app called Console, located in Applications > Utilities. It is a program that compiles and displays the system logs in real time. It's great to see the little things happening in the system that don't make it into the user interface. When I had my Console up and generated that same error you're having, I noticed this error in the log:
    The key here is the Adobe QT32 Server, which is mentioned in the TCP part of the article I linked to above from Todd. In my case at least, what was happening was that a third party app called AirServer was talking to the system's QuickTime over the same TCP ports the QT32 Server engine was trying, and it resulted in Adobe QT32 Server crashing, and that alert being thrown up in AfterEffects.
    If you're in the same boat, it means you have some sort of app or system extension that is also talking to QuickTime over TCP. That may not make any sense, but the easy thing to do is quit ALL third party apps, then quit AE, then restart AE.
    In my situation if AE gave me the error and then I quit AirServer, the error still happened because Adobe QT32 had already crashed. You have to relaunch AE after closing the offending third party app.
    To be sure you've quit all third party apps, open Activity Monitor (Applications > Utilities), chose "My Processes" from the dropdown menu, and scan through the list to make sure. You don't have to recognize all the processes there, but you should be able to recognize any third party ones you put there.
    Hope that helps!
    Matt

  • VPN service module choice 7600-SSC-400 vs. SPA-IPSEC-2G

    Need to decide between the two VPN service module: 7600-SSC-400 and SPA-IPSEC-2G for a 6509 sup 720 3bxl. Not sure what is the difference and couldnt find too much info just searching the internet. What would be the benefits of one or another?

    Hello,
    You will need both. The 7600-SSC-400 is the carrier module of the SPA-IPSec-2G.
    There is more information on this via the following link:
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/6500series/76ovwvpn.html
    Warm Regards,
    Rose

Maybe you are looking for

  • Issue with Search Help Creation

    Hi All, I need to display the match code for the Z table ZPRODUCT and the field is PRODH. The data should be retrieved from the table T179 by filtering PRODH = 'ZZ*' and STUFE = '1'. So, I am trying to create a Search Help for this requirement. But,

  • New HD, can't install OS x

    Installed a new 640 GB hard drive in my mid 2010 core 2 duo, 2.4ghz , macbook pro 13", Macbook Pro 7,1 Boots fine with install disk, 10.6.7 (not original that came with computer) After selecting the language to install, it says "can't install Mac OS

  • Purchase Order Creation, Extended Classic Scenario

    Can someone please explain the different databse tables affected during the creation of a Purchase Order. Also, is there a transaction with which we can create PO in Extended classic scenario?

  • T.code/Report for calculate received values for a subcontract

    Hi Experts, Can you any one help on this issue. u201CIs there a T-code/report that will calculate the received values for a subcontract  broken out by code - or remaining values per code - even when the contract has non-valuated GR lines? MATDOCS doe

  • NAVM / NAVS condition type Use

    Hi Experts, If i am using NAVM/ NAVS condition type in Purchase Pricing Procedure. While creating PO with these condition typeu2019s price is not added to net price. But when I post Goods receipt for PO, condition type value hits the inventory. Can a