What is adapter configuration in XI ?
Dear support,
we have installed neweaver 2004 system and useing the same as XI server.
now developers while working on some html configuration and integration found
THERE IS ADAPETR CONFIGURATION PENDING FROM BASIS POINT OF VIEW.
We have done all required settings like SLD and others to be able to work on j2ee side.
i have gone through weblog /people/venugopalarao.immadisetty/blog/2007/03/15/adapter-engine-cannot-be-found-in-integration-directory
There are two ways to check the adapter engine status in Integration Directory.
Go to integration directory to clear the cache , Environment -> Clear SLD Data Cache.
First: Check the cache notification in ID , Environment menu -> Cache Notification
It should not show any error message 'Adapter Engine not found in Integration Directory'.
Second: Check whether the adapter engine is showing in communication channel level for any adapter either in sender or receiver
But still developers say they are not able to find ADAPTERS list required for their integration and still configuration of Adapters pending , can anybody let me know
what exactly as Basis person i need to do to get Adapters in place for XI system.
Best Regards,
AjitR
hi Ajju,
have you followed installation document ? we should not miss any step in that.
this is common problem.follow as it says in page 46, or you can have exact service level from OSS.
"Importing the XI Content for Software Component Version SAP Basis 6.40 SR1
1. Copy XI3_0_SAP_BASIS_6.40_09_00.tpz from <Components DVD>/XI /XI_CONTENT to directory /usr/sap/<SAPSID>/SYS/global/xi/repository_server/import/
2. On your SAP XI host, call transaction SXMB_IFR.
3. Choose Repository (Design).
4. Choose → Tools → Import Design Objects
2. Choose the file /usr/sap/<SAPSID>/SYS/global/xi/repository_server/import XI3_0_SAP_BASIS_6.40_09_00.tpz
5. Import the file.
Performing Initial Adapter Engine Cache Refresh
Perform the initial cache refresh of the Adapter Engine by executing the following URL:
http://<host>:<Java-Port>/CPACache/refresh?mode=full
Where <host> is the Adapter Engine host and <Java-Port> is the HTTP port of the J2EE engine (The following naming convention applies: 5<Java_instance_number>00. 50000, for example, if your Java instance is 00).
Log on data: XIDIRUSER with password
Check that the response indicates that the cache refresh has been successfully executed."
basically you are missing basis component.you need to import that and do the <b>cache full refresh</b>.it should able to see Adapter in ID and well as list RWB->Component moni-->Adapter monitoring ,you able to see all the greyed adapters there.
and also try searching in SDN there is lot o it about this issue(missing adapters)
Babu
Similar Messages
-
What should be configured as channel in Oracle CEP HTTP adapter for remote publishing?
Hi,
Below is the adapter configuration that I have for Oracle CEP HTTP adapter for remote publishing. What exactly should be configured in <channel> here? In the oracle documentation example, it only says /channel2 as an example.
Below is the HTTP adapter configuration file that I have created.
<?xml version="1.0" encoding="UTF-8"?>
<wlevs:config xmlns:wlevs="http://www.bea.com/ns/wlevs/config/application">
<http-pub-sub-adapter>
<name>HttpPostAdapter</name>
<server-url>http://localhost:8080/RESTfulWS/rest/UserInfoService/post/jsonstream</server-url>
<channel>/RESTfulWS</channel>
<event-type>com.wipro.event.ResultEvent1</event-type>
</http-pub-sub-adapter>
</wlevs:config>
'/RESTfulWS' in my above configuration is the context-root of my rest service.But this is not working so I would like someone to help me understand this configuration.
Many thanks.
Regards
SowmyaHi, Sowmya,
From your configuration
Is the http://localhost:8080/RESTfulWS/rest/UserInfoService/post/jsonstream httppubsub server? I don't think the oep http pub adapter can publish event to rest service.
For http pub adapter, you can take a look at fx sample, it publishes events to a embedded http pub/sub server of oep.
Thanks,
Gala -
What is Operating System commands in Adapter Configuration??
Hi Frnds,
When we will use Operating system commands Option in Adapter Configuration??
Regards,
RajHi,
Go through this blogs..
/people/michal.krawczyk2/blog/2005/08/17/xi-operation-system-command--error-catching
/people/sameer.shadab/blog/2005/09/21/executing-unix-shell-script-using-operating-system-command-in-xi
When we will use Operating system commands Option in Adapter Configuration??
http://help.sap.com/saphelp_nw04/helpdata/en/0d/00453c91f37151e10000000a11402f/content.htm
Go through this link some experts discussions:
Run Operating System Commands
How to run Operating system command in receiver JDBC Adapter
Hope this info is useful to you..
Thanks,
Satya Kumar.. -
Sender JMS adapter configuration for IBM MQSeries
Dear All,
i am doing a IBM MQSeries 5.2.x Message ->sender JMS adapter -> XI server -> receiver RFC adapter -> R/3.
i have deployed the JMS adapter with the required jar files of IBM MQSeries 5.2.x in XI server.
in Sender JMS adapter configuration for IBM MQSeries 5.2.x, i have put following data:
1. Transport Protocol: Websphere MQ - is it okay?
in JMS provider settings:
2. in channel name - what should be there?
3. Transport Network protocol should be TCP/IP or WebsphereMQ - how to decide this thing.
4. JMS Complaint - whether WebsphereMQ or JMS API.
in JMS Settings:
5. JMS Queue user - is this IBM MQSeries 5.2.x Queue User or someother user?
6. JMS Message Selector - what data to take here.
So if anybody has connected IBM MQSeries 5.2.x to XI via JMS adapter, please answer my above queries.
Regards,
Rajeev GuptaHi Swaroop,
you can send me those documents at my gmail-id : [email protected]
Hi All,
one more question - to connect XI server to IBM MQSeries via JMS adapter in ID, do we need to have a MQSeries Client installed on XI server - or - just by configuring JMS adapter, we can send messages from IBM MQSeries to XI server without any MQSeries client on XI server?
Why Channel name is required in JMS configuration data?
Thanks,
Rajeev Gupta -
Error in Adapter Table Adapter Configuration IDM - Oracle 10g
Error in the configuration of Oracle Database Table Adapter Configuration.
Log:
2007-10-02 10:26:40,843 INFO [DBADAPTERLOGGER] DBProvisioner::createUser : DBProvisioner::createUser : userProperties is xel_usr_id#:#V04#;#xel_usr_password#:#56pddssd#;#xel_usr_status#:#1#;#xel_usr_first_name#:#Juana#;#xel_usr_last_name#:#Rengifo#;#xel_usr_group#:##;#xel_usr_title#:#Analista#;#xel_usr_dept#:##;#xel_usr_comm_lang#:##;#xel_usr_logon_lang#:##;#xel_usr_email#:[email protected]#;#xel_usr_tel_no#:#111-222-4444#;#xel_usr_time_zone#:##;#xel_usr_date_fmt#:##;#xel_usr_dec_ntn#:##;#xel_usr_role#:#System Admin
2007-10-02 10:26:40,859 INFO [DBADAPTERLOGGER] DBProvisioner::createUser : Starting time for createUser method :1191346000859
2007-10-02 10:26:40,875 ERROR [DBADAPTERLOGGER] DBSchemaErrorHandler::error : ERROR : 1:227cvc-elt.1: Cannot find the declaration of element 'xl-ddm-data'.
org.xml.sax.SAXParseException: cvc-elt.1: Cannot find the declaration of element 'xl-ddm-data'.Based on your error a few questions come to mind...
What does your Configuration XML file look like? It's root XML node should be xdb_app_map. Your error makes me think you may be pointing at an adapter file versus db schema mapping file.
Are you starting from one of the provided examples like OraApp1.xml? If you followed Step 3: the connector file copy instructions during deployment, you should find the samples in "OIM_home/xellerate/XLIntegrations/DBAppTables/xml/DB_Schema" Or you can search for OraApp1.xml or OraApp2.xml.
Have you configured your IT Resource with the appropriate path to the XML file? If you are on Unix it's going to be case sensitive, I can't speak for a windows path.
I hope this helps. I know I had a few challenges myself when I first took a swing at the DB Table Adapter from the 9.0.4.1 connector pack.
regards,
Jason -
Error in JMS Adapter Configuration...Pls help..
Hi,
My scenario is that FTP->MQ Queue->Local JMS Queue->XI.
MQ Queue has successfully picked up the files from FTP and posted successfully into Local JMS Queue. But XI is unable to pick them up from Local JMS Queue.
It is giving the following error:-
Error during channel initialization; exception trace: javax.jms.JMSException: MQJMS2005: failed to create MQQueueManager for '153.88.140.28:ESEALMW303'
Here are the details what I enetered in the Sender JMS Adapter Configuration:-
Transport Protocol-> WebsphereMQ(Non JMS)
QueueConnection Factory Java Class-> com.ibm.mq.jms.MQQueueConnectionFactory
Queue Java Class->com.ibm.mq.jms.MQQueue
IP address: 153.88.140.28
Server port: 1414
Queue Mgr name ESEALMW303
Channel name MQMA_ESEALMW303_1
JMS queue EAB_MDMTOCBS_LQ01
Any help would be appreciatedSoumya,
Refer Abhy's reply in the below thread
XI JMS error MQJMS2005 : failled to create MQQueuemanager for ....
raj. -
Jms adapter configuration and testing
Hi,
Please inform the JMS adapter configuration and testing.
Thanks
NaiduHi,
tried to reach JMS adapter but was not sure about what to inform it with
Ok, just being silly there... About your problem:
Overview - not complete and a little dated but notetheless good starting point
Exploring JMS and SAP-XI JMS Adaper
JMS FAQ Note - valuable official statements for various questions. Many linked notes which may also be of interrest
http://service.sap.com/sap/support/notes/856346
Driver deployment note
http://service.sap.com/sap/support/notes/1138877
Some other valuable links provided by Chirag Gohil
Re: jms senarios
HTH for starters
Cheers
Jens -
What are the configuration need between R3 and XI when we use RFC sync adap
hi,
What are the configuration need between R3 and XI when we use RFC sync adapter.
Regards
siva.if its the sender adapter ref:
RFC adapter
Sender- /people/michal.krawczyk2/blog/2005/03/29/configuring-the-sender-rfc-adapter--step-by-step
Receiver;
http://help.sap.com/saphelp_nw04/helpdata/en/c8/e80440a832e369e10000000a155106/content.htm
Also;
trouble shooting rfc/soap -
/people/shabarish.vijayakumar/blog/2008/01/08/troubleshooting--rfc-and-soap-scenarios-updated-on-20042009 -
What is Adapter Metadata in Adapter Objects
Hi All,
Q1) What is Adapter Metadata in Adapter Objects in IR ??
Q2) What is Communication Channel Template ???
Wxplain me the Purposes
Regards
VamsiHi Vamsi,
excuse me for my delayed reply.
We can use Integration Scenario from Integration Repository as a template for generating configuration Objects. It takes you through the configuration process, step-by-step. The objects required for the configuration are created and existing objects are checked to ensure that they can be used before including them in a scenario. The relevant objects are predominantly created automatically. The whole process is logged so that you have a good overview and can analyze and understand the configuration.
So Integration Scenario helps you to generate Configuration objects in ID. The configuration wizard that is already there is different might be both the intensions are same.
<i>>>Here I am Saying We can have all those If we Use Configuration Wizard</i>
yes u are exactly correct
But by importing Integration Scenario from IR you will get Integration Scenario Configurator which will embed all the templates and actions included in IR will be generated.
Hope this time you are clarified.
Regards,
Ramesh P -
Internal LAN adapter configuration commands
Could anyone describe me the meaning of hsma
command option:
7206MEDA(cfg-lan-Token 0)#adapter 1 4000.0047.4522
7206MEDA(cfg-adap-Token 0-1)#?
Internal Lan Adapter configuration commands:
hsma Hot Standby MAC Address parameters
Thanks in advance for any informationHi,
I have attached a document describing what hsma is all about in more detail, including sample configurations.
In very simple words. It is a mechanism, a little bit like hsrp, to allow to cip's to backup each other. You configure a virtual adapter which is always only active on one of the two cip's and they monitor each other. If one cip goes down, the other one takes over and activates the virtual adapter.
When the two cip routers were connected to a tokenring infrastructure than the redundancy whas achived by using the same mac address on the cip's reachable over to different source bridged path using different rif's.
If you connect the two cip routers via a ethernet than there is no rif field in your packets anymore, you can not do source bridging. Additional the cam table of a ethernet switch can not deal with two times the same mac address on different ports in the same vlan.
Hsma allows for a similar level of redundancy if your cip routers are connected via a ethernet backbone.
thanks...
Matthias -
Adapter configuration Failed when installing BODS 3.1
Dear All,
I am trying to install BODS 3.1 on windows 8 pro laptop and I have got an error,"Adapter configuration Failed" .
What will be the issue?
Regards,
KathirDear All,
I am trying to install BODS 3.1 on windows 8 pro laptop and I have got an error,"Adapter configuration Failed" .
What will be the issue?
Regards,
Kathir -
SPA122 Unable to log into Phone Adapter Configuration Utility
I am unable to log into the Phone Adapter Configuration Utility for my SPA122. It has never been used before and the default username/password of "admin, admin" is giving me a prompt saying that the username or password are incorrect. I have reset the ATA as well, and it is still giving me this error. Any help???
hi Patty,
what you want to do is hold the reset button for about 30 sec, you should see the lights change ( all come on briefly ).
If the devices is part of a managed service, and has been locked down, the only way to factory reset is with the admin password.
Did you purchase it new? if so, you might try taking it back to your place of purchase.
You can also try using the ivr to reset.
hit **** - you should hear the ivr intro
type 73738 (spell reset)
hit 1 to approve
if that asks for the admin password, then you need the password.
Hope that helps,
-Dan -
What cable/adapter do I need to connect my MacBook Pro to a Sharp Aquos TV?
What cable/adapter do I need to connect my MacBook Pro to a Sharp Aquos TV?
I want to watch videos on youtube or read articles on my laptop, and I want a cable/adapter that will hook up the Macbook to the TV and display the webpage that is on the laptop.Of course it doesn't. But you can buy an adaptor from HDMI to the Mini-DisplayPort port on the computer.
-
I receive an error message (code -17600) while loading my test sequence after switching from LabVIEW Development System (2009 f3) to LabVIEW Run-TIme Engine using the Adapter Configuration.
ErrorCode: -17600,
Failed to load a required step's associated module.
LabVIEW Run-Time Engine version 9.0.1f3.
When I switch back to the LV development system, everything is OK, and the sequence loads and runs perfectly.
My TestStand Engine Version is 2012 f1 (5.0.0.262).
I'd appreciate any help on this issue.
RomanHi Roman,
There are a couple of things you can try:
1) Determine if the LabVIEW RunTime Engine is corrupted in some way. Create a new simple VI with no sub-VIs, using the same LabVIEW Development system you used for mass-compiling the VIs. Create a TestStand step that calls this VI and ensure it runs correctly. Now switch your LabVIEW adapter to use the RuntimeEngine and choose the "Auto detect using VI version" option.
Check if the simple VI is loadable and runs without errors in TestStand.
If the step generates the same error, you should try a re-install of the LabVIEW development system.
If not, its most likely that there is some VI you are using that is not loadable in the LabVIEW Runtime Engine because:
1) Some sub-VI is still not saved in the right version or bitness. Open the VI heirarchy of the top-level VI that you are calling from TestStand and examine the paths of all the sub-VIs to check if they were in the folder you masscompiled and re-save any that are outside this directory.
Also, when you try to close the top level VI, do you get a prompt to save any unsaved files? If so, they could be the sub-VIs that are not saved in the right version. Save all of them.
Check if you are loading any VIs programatically and if these are compiled and saved in the right version as well.
2) There is some feature you are using in your LabVIEW code that is not supported in the LabVIEW RunTime Engine. To check this, add your top-level VI to a LabVIEW project and create a new build specification and create a new executable from this VI.
Right-click "Build Specifications" and choose "New->Application(EXE)".
In the Application Properties window, select Source Files and choose the top level VI as the start-up VI.
Save the properties.
Right-click on the newly created build specification and choose Build.
Run this executable (it will be run using the LabVIEW RunTime) and check if the VI has a broken arrow indicating that it cannot be loaded and run in the LabVIEW Runtime Engine.
You might need to examine your code and find the feature which is not supported in the LabVIEW RunTime and find an alternative.
Another thing i forgot to mention the last time around is if you are using 64-bit LabVIEW with 32-bit TestStand, then executing code using LabVIEW RTE from TestStand will not work since the 64-bit LabVIEW RTE dll cannot be loaded by the 32-bit TestStand process.
If none of the above steps resolve the issue, consider sharing your LabVIEW code so i can take a look.
Regards,
TRJ -
I have an apple cinema display circa 2005. What Thunderbolt adapter will I need in order for it to work with a current model Mac Mini?
see > I have an Apple Cinema Display ADC. What adapters do I need to hookup my ADC connected monitor to my Mac Mini.
or > Using Older Apple ADC Displays with Mac Pro - The Mac Observer
and > Thunderbolt and ADC: Apple Support Communities
Maybe you are looking for
-
Product Name: officejet 6700 Operating System: Microsoft Windows 7 (32-bit) Naming separate scanned pages – for emails When I scan separate attachments docs to go the same email recipient I can't seem to be able to name them separately in detail. Fo
-
New Features in SSM 10.1 SP5
Strategy Management 10.1 SP5 is available for download and includes multiple functional enhancements. Group access for Reports/Dashboards/Briefing Books Ability to manage drafts and "publish" Briefing Books Internet Explorer 11 support Semi-Annual pe
-
Hi, We have one requirement " System should not allow to make GRN before the due date.with 3 days float." With options of Vendor/material/Pur group/MRP controller. Is it possible ? Please suggest any solution nearer to this requirement. Thanks Prasa
-
Is it poosible to retrieve the request back from Production
Hi Experts, Is it possible to retrieve the request back from Production. Regards, IFF
-
MSS attachment in the outbox of workflow
Hi, We are using the ISR scenarios with PDF forms. Once the approver approves the item in the inbox , It goes to the outbox. But the outbox item only has a description I want to add a url link to the PDF form how do I do that.? Thanks, Nanda