What is difference in WEB application designer in bw and bi
what is difference in WEB application designer in bw and bi
new features available in bi
Hi Naman,
Please go through this wonderful link:
bw 7.0
Hope this helps...
Regards,
Habeeb
Assign points if helpfu...
Similar Messages
-
Difference Between Web application design and Report Designer
Hi,
I have searched in the forum as well i Google it but still i am not clear the difference between Web application Designer and report Designer , why especially we go for WAD ? and what is not possible in Report designer which we can do in WAD Please some one explain me that would be great helpful to me. i am having lot of confusion in this issue.
thanks,
GalHi,
The Report designer is completely for formating of your query and results. Here you have the flexibility to design your query(one/more) results in your own way.
The WAD is for displaying various web items at one short for a single/multiple query. And here you have the flexibility to do the XML coding on the web items, but not as much you have the flexibility on Report Designer.
But, Report designer will have more performance issues than WAD. So, generally it helps when you need extreme formating of your reports.
Hope this clears your doubt.
Regards,
Srinivas. -
What GUI to use web application designer in BI 7.0 without support package
I use BI in my ECC 6.0 system.
I use tried both GUI 7.1 and GUI 6.40 to logon web application designer.
But system display the message please logon to a Netweaver BI 7.x system. System A11 does not have a mimumium version required 7007.
My system seems to be 7000, so what GUI is suitable to use for WAD?
Thanks
GiangHi,
It could be problem with either Support package which you are using for BI or Front end patch which you need to install for GUI.
please check with minimal installations and let me know with current support package and FEP you are using.
Regards
Suresh -
Web Application Designer 3.5 and Filter-Item with Structure
Hello,
I have the filter-item in a web application which is based on a query with a structure in the rows. Now I want to disable the visibility of the structure in the filter-element. Is that possible?
Edited by: Gerrit Lober on Jun 9, 2008 2:15 PMHi,
is the structure in the rows the structure of the key figures? or did you create your own structure for the characteristics?
don't think it's possible...
ciao
Joke -
BEx Web Application Designer old tool?
Hi,
Someone told me that BEx Web Application Designer is an old tool that's not used anymore. And that Visual Composer and Web Dynpro are better tools to use. Is this correct?
Also, I was wondering if anyone could explain the difference between BEx Web Application Designer, Visual Composer and Web Dynpro. What situations do one use the different tools?
Kind regards,
Maria PerezMaria
Welcome to SDN
Bex Web Application is not an old tool and it is widley used for Web Reporting.
Actually the purpose of these three tools are different so all of them are extensively used.
Please see the following links for more details
Visual Composer
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/45bfd990-0201-0010-e1b3-a38f22a5b5b2
Webdynpro
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/7bfea990-0201-0010-44a7-84a74971b795
Web Application Designer
http://help.sap.com/saphelp_nw04/helpdata/en/1a/456a3badc1b315e10000000a114084/content.htm
Hope this helps
Thnaks
Sat -
Print a Web Template with Web Application Designer 3.X
Hello
I would know how I can print a web template made with Web Application Designer 3.X and that it is in the Intranet.
Actually I'm printing that page with the option of the browser (Internet Explorer) but it print only I see, no print all the chart and the rest of the columns.
How can I print all the data that compose the web template?
Thank you.Hello Sharath,
First check whether you have change authorizations for WAD, check you user name is added in the role for web templates and also check the authorizations.
then in the web template in the menu bar go to view option ,select web items and properties , so that you can find them in the left hand side, then replace the chart item with the table and assign the query to the table.
hope it is clear,
assign points if useful. -
What is WAD(Web Application Design)?
hi all,
<b>What is WAD(Web Application Design)?</b>
any help our document related to the topic is welcome.
any help will be highly Appretiated...
thanks and regards
vinit soniHi Vinit,
WAD is a tool for creating web reports and for displaying reports in browser
See the links in the thread
WAD Material
Web Application Designer for Beginners
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/749a4622-0a01-0010-36bf-b6b30a2a3a22
Have a look at these links
http://help.sap.com/saphelp_nw04/helpdata/en/1a/456a3badc1b315e10000000a114084/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/47/d4fed1c60a9743ade3b4cf306d5d48/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/40/8b174082fe1961e10000000a155106/content.htm
Thanks & Regards,
Suvarna Chittoor.
Award points if helpful -
Problem with layout in Web Application Designer
Hi all,
I am working with the BEx Web Application Designer. Well, I execute a web template in the browser, click on right button and choose enhanced menu, query properties and mark the check box Display Rows as Hierarchy and Expand to and from the list of values (combo-box) choose the last field that can be expanded.
Once all the lines have been expanded and the layout of the template is longer than a page, we look for a line that is not in the first page and contract it. The problem is that when we contract the line, the layout shows the first page, instead of the page where the line had been contracted. I have tried to solve this changing the properties that appear when the template is designed, but I haven´t found the solution. Is there any way so that i can solve it?
Thanks in advance,
Mª del Mar Bonilla.Bonilla,
Welcome to SDN...
Try this out...
In the Query designer view , right click on the rows structure and select display as hierarchy. In case this option works fine , the behavior pointed out by you could be a possible bug.
Just update the result of what I have mentioned above...
Hope it helps..
Arun
P.S Assigning points is a way fo saying thank you in SDN -
Unable to open WAD (web application designer) in BW 3.5!
Hi,
when i open WAD through menu path (start->programs
->Business explorer->Web application designer), i am getting the following error!
WADConst
Please log on to a Netweaver BI 7.x system. System J2E does not have the minimum version required 70005.
I just can`t understand from where i got this BI 7.x system, when my system is BW 3.5 (NW04 platform).
can any one expalin me what is this problem? and suggest me to over come this problem?
Thanks,
RaviHi Ravi!
I assume that you installed the SAP GUI 6.40 with BI Addin (which contains the BI Frontend for SAP NetWeaver 2004s BI).
In this case, you have a sub folder underneath "Business Explorer" in your startmenu named "Business Explorer (SAP BW 3.x)".
You have to use this version of the BEx Web Application Designer.
If this is not the case, please create a Support Message with all detailed information (backend and frontend versions).
Thank you,
Tobias -
Security for creating web templates using web application designer
I work for ChevronTexaco as a BW Security Analyst. I have a request to set up roles for web template creation using the Web Application Designer. Where can I get help in setting up the security for these types of roles? My experience is in setting up roles for running and creating queries in BEX. I need to know what additional authorizations will enable web template creation. Setting up a trace in ST01 has been less than helpful since it dumps out tons of RS_COMP tracing that doesn't help me much.
The user wants to be able to create web templates for existing queries in BEX and restrict by rs_comp infocubes/areas/reportid, etc. and to be able to save to restricted role names. Are there new auth groups specific to this type of activity that I need to code for in addition to the basic end user or report builder authorizations?
Any help would be greatly appreciated.
Jeff Ehritt
925 827-6012
ChevronTexacoThanks Marc, I'll check it out. My problem was that I was trying to create the role by granting a userid sap_all, sap_new and s.a_system as well as power user auths for a specific application. I set up a trace in ST01 for authorization cking on the ID while one of our BW Central Support people went into Web Designer to create a template and everything else they wanted to do.
The resulting trace spewed out so much stuff from S_RS_comp and comp1 as to be virtually useless since it named scores of different cubes and infoareas that the analyst wasn't even interested in. The results puzzled me and made it extremely difficult to pin down the required authorizations. Usually ST01 can be used as a blueprint to create the role,ie; everything that the user touches is traced but no more than that. Have you seen this before? With just the new role I had set up the user could not save to a role unless I coded the fully qualified role name such as YRH_SENDAT_USER. YRH* would not work.
Thanks,
Jeff Ehritt
ERP COE SAP BW Security -
Security For BW Web Application Designer
I work for ChevronTexaco as a BW Security Analyst. I have a request to set up roles for web template creation using the Web Application Designer. Where can I get help in setting up the security for these types of roles? My experience is in setting up roles for running and creating queries in BEX. I need to know what additional authorizations will enable web template creation. Setting up a trace in ST01 has been less than helpful since it dumps out tons of RS_COMP tracing that doesn't help me much.
The user wants to be able to create web templates for existing queries in BEX and restrict by rs_comp infocubes/areas/reportid, etc. and to be able to save to restricted role names. Are there new auth groups specific to this type of activity that I need to code for in adition to the basic end user or report builder authorizations?
Any help would be greatly appreciated.
Jeff Ehritt
925 827-6012
ChevronTexacoHi Jeff,
there are no special authorization objects for Web Templates. RS_COMP will still only work for queries, structures.... Saving to roles requires certain authorizations for the role (s_agr_*), here you can define the roles you can save templates to.
Regards, Klaus -
RSBOLAP 018 Java system error in BEx Web Application Designer
Hello,
while doing inside BEX Web Application Designer "validation of webtemplate" with
command "validate on server" I get following error message of WAD :
" Message RSBOLAP 018 description : Java system error : an Unknow Error occured during portal communication"
My procedure till now was ( please see results as screenshots in attachment) :
a) ckecking prerequisites for "Java template installer'" --> result "prerequisites.jng"
b) running "Java template installer" -> " result templateInstaller.jpg"
c) running Bex Web Application Designer as mentioned above results in error
message as mentioned above
d) running Diagnostic & Support Desktop Tool --> "result Diagnostic support desktop tool.jpg"
It says that something is wrong with "BI Mastersystem" because of failed connect to
message server.
Please advice me what I should do.
Thanks in advance
Regards,
OscarHello
It is obvious that the connection between the ABAP and the Java is not working.
There should be a JCo RFC from the portal side to the ABAP stack set up and an RFC from the ABAP stack to the portal.
Check the entries of the table RSPOR_T_PORTAL
The RFC specified here should be the one mentioned above (ABAP - Java)
Check the name of the system should be SAP_BW
Is the parameter icm/host_name_full set on the ABAP stack with the domain name ?
Connect to the BI portal:
http://FQDN:5NN00/irj/portal
Navigate to system administration -> system configuration -> system landscape -> expand "portal content" -> systemlandscape -> SAP_BW
Right click on SAP_BW - Open - Object
Here you need to maintain these:
ITS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
ITS Host Name - FQDN_OF_BW_ABAP:port - You can use the value of icm/host_name_full parameter and retrieve port number from Tx SMICM - Services
ITS Path - /sap/bc/gui/sap/its/webgui
ITS Protocol - Select http
Logical System Name - BW ABAP Logical System Name - Tx SCC4 or BD54
Logon Method -SAPLOGONTICKET
Message server - BW ABAP FQDN
SAP Client - BW ABAP Client Number
SAP System ID (SID) - BW ABAP SID
Server Port - 39NN
Web AS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
Web AS Host Name - FQDN_OF_BW_ABAP:port - icm/host_name_full and retrieve port number from Tx SMICM - Services
Web AS Path - /sap/bw/BEx
If everything is set properly then do a test connection.
Good Luck
RB -
Report to Report - Web Application Designer
I have created a simple template using BEx Web Application Designer. The Query I've picked is set up with receiver reports. e.g. I want to do a report to report interface from the data in my template to another query and another template. However when I choose Goto on the data and select the query I want it opens the data but opens it using a template I havent created. A standard template? How do I get the query I go to to open with one of my templates? Do I have to do some linking somewhere?
Hello Joel,
Have you put your new template in 'Set standard web templates'?
Txn rscustv27? this may not work but it is worth a try. u would need to put it in the bottom option.
Another way to do this would be to create an iview for each query and in the the query properties you can assign what template you will use under 'bex web application query string'. The iView properties can be found in the Portal Content Directory. i think this will definatley work.
Also one other thing to look at in WAS is the RRI options (in the properties of the web template). This may have something in there.
Enjoy your friday.....
Nick. -
Web application Designer - RFC Exception
Hy guru, i have a serious problem: when open or execute a web templat on web application designer 7.0 i receive a error type RFC Exception.
Could you hlep me? Thank's a lot.
This is the content of bex_trace file:
-EXCEPTION-START- : Open Save Services Failure. Breaking the Action. ---
Exception Message: Check: RFC Exception
Exception at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.RFCGetMessages(String& piLastNCalls, BExMessages& peMsgList)
at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.ClearServerMessageHandler()
at com.sap.bi.et.BExOpenSaveServices.OSDialog.GetHistory(BExObjectType pObjType, BExMessages& peMessages)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.GetHistoryTemplateList()
Full Stack:
at com.sap.bi.et.wad.Debug.WriteTraceToFile(Level, String, Exception)
at com.sap.bi.et.wad.Trace.Exception(Exception, String)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.GetHistoryTemplateList()
at com.sap.bi.et.wad.man.WADTemplateController.GetHistoryForDisplay()
at com.sap.bi.et.wad.man.WADfrmMDIInitialSelection.renderHistory()
at com.sap.bi.et.wad.man.WADfrmMDIInitialSelection.Refresh()
at com.sap.bi.et.wad.man.WADfrmMainWindow.RefreshInitialTemplateList()
at com.sap.bi.et.wad.man.WADTemplateController.OnTemplateOpened(WebTemplate)
at com.sap.bi.et.wad.pageobjects.TemplateOpenedEventHandler.Invoke(WebTemplate)
at com.sap.bi.et.wad.pageobjects.WebTemplateFactory.AddTemplateOrLibrary(WebTemplate)
at com.sap.bi.et.wad.pageobjects.WebTemplateFactory.RegisterTemplateOrLibrary(IWebTemplate)
at com.sap.bi.et.wad.man.WADTemplateController.LoadTemplate(EnumLoadMode, String, String, Boolean, String, Boolean, Boolean)
at com.sap.bi.et.wad.man.WADTemplateController.DoLoadTemplateFromBW(String)
at com.sap.bi.et.wad.man.WADfrmMainWindow.Menu_OpenSelectOH(BExOpenHistoryEventArgs)
at com.sap.bi.et.common.BExOH.BExOpenHistory.RaiseSelectOpenEntry(dtaBExOHRow)
at com.sap.bi.et.wad.man.WADfrmMDIInitialSelection.StartTemplate(dtaBExOHRow)
at com.sap.bi.et.wad.man.WADfrmMDIInitialSelection.lblLinkName_LinkClicked(Object, EventArgs)
at System.Windows.Forms.Control.OnClick(EventArgs)
at System.Windows.Forms.Control.WmMouseUp(Message&, MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(Message&)
at System.Windows.Forms.Label.WndProc(Message&)
at System.Windows.Forms.ControlNativeWindow.OnMessage(Message&)
at System.Windows.Forms.ControlNativeWindow.WndProc(Message&)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG&)
at System.Windows.Forms.ComponentManager.System.Windows.Forms.UnsafeNativeMethods+IMsoComponentManager.FPushMessageLoop(Int32, Int32, Int32)
at System.Windows.Forms.ThreadContext.RunMessageLoopInner(Int32, ApplicationContext)
at System.Windows.Forms.ThreadContext.RunMessageLoop(Int32, ApplicationContext)
at System.Windows.Forms.Application.Run(Form)
at com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----
END com.sap.bi.et.wad.WADBackend.WADOSDialogues.GetHistoryTemplateList ##########
--> com.sap.bi.et.wad.WADBackend.WADBackendTemplateServices.ValidateTemplateOnServer ##########
-EXCEPTION-START- : DEBUG ### JSP-Conversion: ---
Exception Message: RFC_ERROR_SYSTEM_FAILURE
Exception at SAP.Connector.SAPConnection.ThrowRfcException(RFC_ERROR_INFO_EX rfcerrInfo, Encoding encoding, String languangeCode)
at SAP.Connector.Rfc.RfcClient.RfcInvoke(SAPClient proxy, String method, Object[] methodParamsIn)
at SAP.Connector.SAPClient.SAPInvoke(String method, Object[] methodParamsIn)
at com.sap.bi.et.Communication.RSWAD.BExGeneratedRSWAD.RSWAD_WEBPUB_CALL_SERVICE(String I_ACTION, String I_CONTEXTDESCRIPTION, String I_CONTEXTFRAGMENT, String I_NODEFRAGMENT, String I_TEMPLATE, String I_TMPLID, String& E_MAX_MESSAGE_TYPE, String& E_MESSAGES, String& E_RESULT, Int32& E_SUBRC, BICS_PROV_T_MESSAGE& E_T_MESSAGE)
at com.sap.bi.et.Communication.RSWADrfc.RSWAD_WEBPUB_CALL_SERVICE(String& I_ACTION, String& I_CONTEXTDESCRIPTION, String& I_CONTEXTFRAGMENT, String& I_NODEFRAGMENT, String& I_TEMPLATE, String& I_TMPLID, String& E_MAX_MESSAGE_TYPE, String& E_MESSAGES, String& E_RESULT, Int32& E_SUBRC, BICS_PROV_T_MESSAGE& E_T_MESSAGE)
at com.sap.bi.et.wad.WADBackend.WADBackendTemplateServices.ValidateTemplateOnServer(WebTemplate iTemplate)
Full Stack:
at com.sap.bi.et.wad.Debug.WriteTraceToFile(Level, String, Exception)
at com.sap.bi.et.wad.Debug.Exception(String, Exception)
at com.sap.bi.et.wad.WADBackend.WADBackendTemplateServices.ValidateTemplateOnServer(WebTemplate)
at com.sap.bi.et.wad.man.WADTemplateManipulator.ValidateTemplate(WebTemplate)
at com.sap.bi.et.wad.man.WADfrmMainWindow.itmValidateOnTheServer_Click(Object, EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.OnItemClicked(EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.PerformClick()
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.NotifyItem(BarItem)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.HidePopup(PopupCloseType)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.ProcessItemClick(BarItem)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.OnMouseUp(MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(Message&, MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(Message&)
at Syncfusion.Windows.Forms.ScrollControl.WmMouseUp(Message&)
at Syncfusion.Windows.Forms.ScrollControl.WndProc(Message&)
at Syncfusion.Windows.Forms.Grid.GridControlBase.WndProc(Message&)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.WndProc(Message&)
at System.Windows.Forms.ControlNativeWindow.OnMessage(Message&)
at System.Windows.Forms.ControlNativeWindow.WndProc(Message&)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG&)
at System.Windows.Forms.ComponentManager.System.Windows.Forms.UnsafeNativeMethods+IMsoComponentManager.FPushMessageLoop(Int32, Int32, Int32)
at System.Windows.Forms.ThreadContext.RunMessageLoopInner(Int32, ApplicationContext)
at System.Windows.Forms.ThreadContext.RunMessageLoop(Int32, ApplicationContext)
at System.Windows.Forms.Application.Run(Form)
at com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----
: DEBUG ### False - RSWAD_WEBPUB_CALL_SERVICE:V:Validate on Server returned e_subrc=99
END com.sap.bi.et.wad.WADBackend.WADBackendTemplateServices.ValidateTemplateOnServer ##########
--> com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenObject ##########
-EXCEPTION-START- : Open Save Services Failure. Breaking the Action. ---
Exception Message: Check: RFC Exception
Exception at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.RFCGetMessages(String& piLastNCalls, BExMessages& peMsgList)
at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.ClearServerMessageHandler()
at com.sap.bi.et.BExOpenSaveServices.OSDialog.OpenObject(BExObjectType pServiceObjType, BExObjectType[] pSelectableSubObjTypes, Form pParentForm, String pDlgTitle, BExMessages& peMessages)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenObject(Form parent, String iType)
Full Stack:
at com.sap.bi.et.wad.Debug.WriteTraceToFile(Level, String, Exception)
at com.sap.bi.et.wad.Trace.Exception(Exception, String)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenObject(Form, String)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenSimpleObject(BExObjectType, String&, String&, Form)
at com.sap.bi.et.wad.man.WADTemplateController.DoLoadTemplateFromBW(String)
at com.sap.bi.et.wad.man.WADfrmMainWindow.itmOpenWebTemplate_Click(Object, EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.OnItemClicked(EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.PerformClick()
at Syncfusion.Windows.Forms.Tools.XPMenus.BarRenderer.OnMouseUp(MouseEventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.OnMouseUp(MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(Message&, MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(Message&)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.WndProc(Message&)
at System.Windows.Forms.ControlNativeWindow.OnMessage(Message&)
at System.Windows.Forms.ControlNativeWindow.WndProc(Message&)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG&)
at System.Windows.Forms.ComponentManager.System.Windows.Forms.UnsafeNativeMethods+IMsoComponentManager.FPushMessageLoop(Int32, Int32, Int32)
at System.Windows.Forms.ThreadContext.RunMessageLoopInner(Int32, ApplicationContext)
at System.Windows.Forms.ThreadContext.RunMessageLoop(Int32, ApplicationContext)
at System.Windows.Forms.Application.Run(Form)
at com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----
-EXCEPTION-START- : Open Save Services Failure. Breaking the Action. ---
Exception Message: Check: RFC Exception
Exception at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.RFCGetMessages(String& piLastNCalls, BExMessages& peMsgList)
at com.sap.bi.et.BExOpenSaveServices.OSDataProvider70.ClearServerMessageHandler()
at com.sap.bi.et.BExOpenSaveServices.OSDialog.OpenObject(BExObjectType pServiceObjType, BExObjectType[] pSelectableSubObjTypes, Form pParentForm, String pDlgTitle, BExMessages& peMessages)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenObject(Form parent, String iType)
Full Stack:
at com.sap.bi.et.wad.Debug.WriteTraceToFile(Level, String, Exception)
at com.sap.bi.et.wad.Trace.Exception(Exception, String)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenObject(Form, String)
at com.sap.bi.et.wad.WADBackend.WADOSDialogues.OpenSimpleObject(BExObjectType, String&, String&, Form)
at com.sap.bi.et.wad.man.WADTemplateController.DoLoadTemplateFromBW(String)
at com.sap.bi.et.wad.man.WADfrmMainWindow.itmOpenWebTemplate_Click(Object, EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.OnItemClicked(EventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.PerformClick()
at Syncfusion.Windows.Forms.Tools.XPMenus.BarRenderer.OnMouseUp(MouseEventArgs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.OnMouseUp(MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(Message&, MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(Message&)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.WndProc(Message&)
at System.Windows.Forms.ControlNativeWindow.OnMessage(Message&)
at System.Windows.Forms.ControlNativeWindow.WndProc(Message&)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG&)
at System.Windows.Forms.ComponentManager.System.Windows.Forms.UnsafeNativeMethods+IMsoComponentManager.FPushMessageLoop(Int32, Int32, Int32)
at System.Windows.Forms.ThreadContext.RunMessageLoopInner(Int32, ApplicationContext)
at System.Windows.Forms.ThreadContext.RunMessageLoop(Int32, ApplicationContext)
at System.Windows.Forms.Application.Run(Form)
at com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----Andrea,
Try using ST22 to see if it gives you a detailed error message. If it is listed it will tell you what it is missing.
Cheers,
Rusty -
Web Application Designer standstill since BW SP25 / BI Java SPS 23
Hi experts,
in February we implemented the latest SPs into a SAP development system of our customer.
Since then the BEx Web Application Designer doesn't work anymore for them.
It just hangs up and you cannot even close it.
I will provide the tracefile in an answer to this post because otherwise the post won't be readable.
I've found note 1437358 concerning NullPointerException (but not NullReferenceException) but I doubt that this has something to do with our issue.
Does anybody have an idea what could cause this problem and how it could be solved?
WAD 7.20 is used.
Best wishes
Marie10:57:23.559: Info: Web Application Designer Start. Revision: 7100.4.1200.491
BExCheckFrontend.CheckFrontend: No Check performed (20110322) 0
10:57:32.933: Connected. System: HWT
-EXCEPTION-START- 10:57:35.198: DEBUG EXCEPTION ### ---
Exception Name: ArgumentException
Exception Message: Das Element wurde bereits hinzugefügt. Schlüssel im Wörterbuch:tartitle. Hinzuzufügender Schlüssel: tartitle.
Exception bei System.Collections.Hashtable.Insert(Object key, Object nvalue, Boolean add)
bei System.Collections.Hashtable.Add(Object key, Object value)
bei System.Collections.Specialized.StringDictionary.Add(String key, String value)
bei com.sap.bi.et.wad.wadconst.WADShortNames.InitShortNames(XmlDocument iTagList, XmlNamespaceManager insmgr)
bei com.sap.bi.et.wad.man.WADfrmMainWindow.PubMainWindow_Load(Object eventSender, EventArgs eventArgs)
bei System.EventHandler.Invoke(Object sender, EventArgs e)
bei System.Windows.Forms.Form.OnLoad(EventArgs e)
bei System.Windows.Forms.Form.OnCreateControl()
bei System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)
bei System.Windows.Forms.Control.CreateControl()
bei System.Windows.Forms.Control.WmShowWindow(Message& m)
bei System.Windows.Forms.Control.WndProc(Message& m)
bei System.Windows.Forms.ScrollableControl.WndProc(Message& m)
bei System.Windows.Forms.ContainerControl.WndProc(Message& m)
bei System.Windows.Forms.Form.WmShowWindow(Message& m)
bei System.Windows.Forms.Form.WndProc(Message& m)
bei System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
bei System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
Full Stack: bei com.sap.bi.et.common.appl.Log.Debug.WriteTraceToFile(Level lLevel, String lString, Exception ex)
bei com.sap.bi.et.common.appl.Log.Debug.Exception(Exception ex, String iAdditionalInformation)
bei com.sap.bi.et.common.appl.Handlers.OnGuiUnhandledException(Object iSender, ThreadExceptionEventArgs iEventArgs)
bei System.Windows.Forms.Application.ThreadContext.OnThreadException(Exception t)
bei System.Windows.Forms.Control.WndProcException(Exception e)
bei System.Windows.Forms.Control.ControlNativeWindow.OnThreadException(Exception e)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.CommandBarController.AppMainFormWnd.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.XPMenus.MenuActivationControl.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.MainWindowSubclass.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.SafeNativeMethods.ShowWindow(HandleRef hWnd, Int32 nCmdShow)
bei System.Windows.Forms.Control.SetVisibleCore(Boolean value)
bei System.Windows.Forms.Form.SetVisibleCore(Boolean value)
bei System.Windows.Forms.Control.Show()
bei com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----
-CALLING-FROM- 10:57:35.198: DEBUG EXCEPTION ### ---
bei com.sap.bi.et.common.appl.Log.Debug.WriteTraceToFile(Level lLevel, String lString, Exception ex)
bei com.sap.bi.et.common.appl.Log.Debug.Exception(Exception ex, String iAdditionalInformation)
bei com.sap.bi.et.common.appl.Handlers.OnGuiUnhandledException(Object iSender, ThreadExceptionEventArgs iEventArgs)
bei System.Windows.Forms.Application.ThreadContext.OnThreadException(Exception t)
bei System.Windows.Forms.Control.WndProcException(Exception e)
bei System.Windows.Forms.Control.ControlNativeWindow.OnThreadException(Exception e)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.CommandBarController.AppMainFormWnd.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.XPMenus.MenuActivationControl.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.NativeWindow.DefWndProc(Message& m)
bei System.Windows.Forms.NativeWindow.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.MainWindowSubclass.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.SafeNativeMethods.ShowWindow(HandleRef hWnd, Int32 nCmdShow)
bei System.Windows.Forms.Control.SetVisibleCore(Boolean value)
bei System.Windows.Forms.Form.SetVisibleCore(Boolean value)
bei System.Windows.Forms.Control.Show()
bei com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-START- 10:57:47.399: DEBUG EXCEPTION ### ---
Exception Name: NullReferenceException
Exception Message: Der Objektverweis wurde nicht auf eine Objektinstanz festgelegt.
Exception bei com.sap.bi.et.wad.man.WADfrmMainWindow.RefreshInitialTemplateList()
bei com.sap.bi.et.wad.man.WADTemplateController.OnTemplateOpened(WebTemplate iTemp)
bei com.sap.bi.et.wad.pageobjects.WebTemplateFactory.TemplateOpenedEventHandler.Invoke(WebTemplate iTemplate)
bei com.sap.bi.et.wad.pageobjects.WebTemplateFactory.AddTemplateOrLibrary(WebTemplate iTemplate)
bei com.sap.bi.et.wad.pageobjects.WebTemplateFactory.RegisterTemplateOrLibrary(IWebTemplate iWebTemplate)
bei com.sap.bi.et.wad.man.WADTemplateController.LoadTemplate(EnumLoadMode iLoadMode, String iFileName, String iTechName, Boolean iAsLibrary, String iEnqueueMode, Boolean iAsCopy, Boolean iForceRawEdit)
bei com.sap.bi.et.wad.man.WADTemplateController.DoLoadTemplateFromBW(String iTechname)
bei com.sap.bi.et.wad.man.WADfrmMainWindow.itmOpenWebTemplate_Click(Object eventSender, EventArgs eventArgs)
bei Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.OnItemClicked(EventArgs args)
bei Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.PerformClick()
bei Syncfusion.Windows.Forms.Tools.XPMenus.BarRenderer.OnMouseUp(MouseEventArgs e)
bei Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.OnMouseUp(MouseEventArgs e)
bei System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
bei System.Windows.Forms.Control.WndProc(Message& m)
bei Syncfusion.Windows.Forms.Tools.XPMenus.BarControlInternal.WndProc(Message& m)
bei System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
bei System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
Full Stack: bei com.sap.bi.et.common.appl.Log.Debug.WriteTraceToFile(Level lLevel, String lString, Exception ex)
bei com.sap.bi.et.common.appl.Log.Debug.Exception(Exception ex, String iAdditionalInformation)
bei com.sap.bi.et.common.appl.Handlers.OnGuiUnhandledException(Object iSender, ThreadExceptionEventArgs iEventArgs)
bei System.Windows.Forms.Application.ThreadContext.OnThreadException(Exception t)
bei System.Windows.Forms.Control.WndProcException(Exception e)
bei System.Windows.Forms.Control.ControlNativeWindow.OnThreadException(Exception e)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg)
bei System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData)
bei System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
bei System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
bei System.Windows.Forms.Application.Run(Form mainForm)
bei com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
-EXCEPTION-END----
-CALLING-FROM- 10:57:47.399: DEBUG EXCEPTION ### ---
bei com.sap.bi.et.common.appl.Log.Debug.WriteTraceToFile(Level lLevel, String lString, Exception ex)
bei com.sap.bi.et.common.appl.Log.Debug.Exception(Exception ex, String iAdditionalInformation)
bei com.sap.bi.et.common.appl.Handlers.OnGuiUnhandledException(Object iSender, ThreadExceptionEventArgs iEventArgs)
bei System.Windows.Forms.Application.ThreadContext.OnThreadException(Exception t)
bei System.Windows.Forms.Control.WndProcException(Exception e)
bei System.Windows.Forms.Control.ControlNativeWindow.OnThreadException(Exception e)
bei System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bei System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg)
bei System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(Int32 dwComponentID, Int32 reason, Int32 pvLoopData)
bei System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
bei System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
bei System.Windows.Forms.Application.Run(Form mainForm)
bei com.sap.bi.et.wad.BexWebApplicationDesigner.Launch.Main()
Maybe you are looking for
-
How to create Mount Point in Linux
Hi, I m new to Linux OS, want to install Oracle EBS R12 on OEL 5.6 . I have downloaded s/w and installed all required packages for OEL. Now i want to create Staging directory at location /u01/StageR12. Can anyone guide me for how to create Mount poin
-
When converting higher bitrate songs to 128 does it alter the music library on the pc?
I have an iPhone 5S 64 GB and an iPod Nano 6th generation 16 GB that I sync to a windows based PC. I have 15.28 GB of music on my PC. It fits nicely as is and at the higher bitrate. I would love to put all that music on my iPod. I am curious if I con
-
Syncing iPad Photos with more that 1 computer
I haven't tried this yet, but can you sync photos on your iPad with more that 1 computer (PC or Mac)? I have a Macbook and a iMac and would like to sync photos between my them and my iPad. Will this work without losing photos on any of the devices?
-
Please recommend between Macbook pro retina and non-retina.
I need to buy Macbook pro 13 but confused between Retina & non-retina. My main use is internet browsing, watching movies, & email (movies with mainly bluray) So what would you recommend? Does the non retina plays movies (bluray) with good quality?
-
Dear Customer, It hase come to our attention that your account billing Information records are out of date. That requires you to update your Billing Information. Failure to update your records will result in account termination records... Click on th