hi ,when i use VSAE to create a console task (there was no template to generate  console task),so i use 2007 r2 authoring tool to generate the xml, then i paste the code in VSAE,but VSAE can not build the management pack , and i also tried
 sample code here http://msdn.microsoft.com/en-us/library/jj130203.aspx ,VSAE can not validate the XML file
the error was:
The 'Category' attribute is not declared
The element 'ConsoleTask' has invalid child element 'Application'. List of possible elements expected: 'Criteria, Assembly'.
The 'Category' attribute is not declared
the project was operation manager 2007 r2 management pack.
I find the XML schema in 'C:\Program Files (x86)\Microsoft Visual Studio 12.0\Xml\Schemas\SystemCenter\FragmentSchemaOM10.xsd' was defferent from the one here 'C:\Program Files\System Center MP Authoring Console
2007\MP Schema\ManagementPackSchema.xsd' ,
the ConsoleTask which defined in the schema of 2007 r2 authoring tool was:
The ConsoleTask which defined in the schema of  in VSAE:
So , is this a bug? or which schema was the right one ?
yoke88
IM:[email protected]

I've run into a similar problem with reporting in the past - I asked the question here, but don't have a thread id for you. The answer I received from the VSAE developer was
basically, VSAE automatically performs a conversion to schema 2.0 during build time, and if it is actually version 1.0 that you are working with you may (will) receive validation errors.
This doesn't help you much, but my solution was to write the pack using version 2.0 schema requirements, regardless if it was for SCOM 2007 or 2012...
Is it a bug??? In my opinion, it is a design flaw.
Jonathan Almquist | SCOMskills, LLC (http://scomskills.com)

Similar Messages

  • SCOM 2012/SP1/R2 - What Is the Best Management Pack for HP Storage (P2000)

    Hi all!
    What would be the best recommended Management Pack for HP Storage (P2000) for the SCOM 2012/SP1/R2? Free products are privileged, of course, but we would also consider the paid ones.
    Thank you very much for your time and attention!
    Best regards!

    Hi,
    Recently I created Custom Management pack for MSA P2000 Storage. Its primary purpose is to monitor performance.
    See: http://jurelab.wordpress.com/ for details.
    Hope it helps
    Jure

  • What is the right choice ?

    Dear all,
    I am on SAP R/3 4.7 Ext 2.
    All my custum forms are written in 3 ways:
    1) Pure Sapscript
    2) Outside SAP with a third part product called "Adobe Output Central Pack" ( in the past was Accelio and previous again Jetform )
    3) In a mixed way of the previous two ways
    I don't like to depend on "Adobe Output Central Pack" for a lot of reasons so I tried in the past to push my company on convert all the forms with Smartform in order to bring all inside SAP. But "Adobe Output Central Pack" was a big economic effort and also the Smartform conversion has been evaluated as a big effort with few benefits.
    Now I read about Interactive Forms and also Adobe people spoke to me about another product called Livecycle Form.
    In your opinion what is the right way to choose ?
    Is Smartform already history ?
    Now people ask for printed forms, pdf files and so on.
    I thougth that smartform was the solution.
    Does I need in any case a third part product in order to save time and money and have good results ( This is what my company ask us everyday ) ?
    Than you in advance for your answer.
    Kind regards
    Mauro Fallavollita

    Hi Mauro,
    just a couple of clarifications to add.
    Interactive Forms ist a cooperation of SAP and Adobe, and the features and functions shipped by SAP are a subset of what Adobe offers with their stand-alone products from the LiveCycle family, which is why Adobe would position those products separately from the SAP integration. So while we include third-party software, because we believe it is currently the best possible solution, SAP is your contact for any issue around the Interactive Forms solution.
    Smart Forms and SAPscript as the legacy tools for non-interactive forms will continue to be shipped by SAP so that all existing forms will continue to run as before. That means Smart Forms is not history.
    Naturally, with the increasing use of Interactive Forms for interactive scenarios (something you can't do with Smart Forms or SAPscript), you may reach the point where you ask yourself whether it makes sense to consolidate all your forms in one technology.
    The goal of the integration of the Adobe LiveCycle Designer into SAP was to make the form design faster and easier. From SAP-internal experience (about 200 developers have worked with the solution), I can say that it does save time and money once you are familiar with the way the tool works.
    Kind regards,
    Markus Meisl
    SAP NetWeaver Product Management

  • The selected management pack cannot be deleted.

    I'm having problems deleting a custom management pack in SCOM 2012. The error is the following:
    The selected management pack cannot be deleted. This might be because it is currently being deleted or it has already been deleted. If you think this message is in error, try again later.
    Any ideas?

    I face the same problem in SCOM 2012 SP1
    The selected management pack cannot be deleted. This might be because it is currently being deleted or it has already been deleted. If you think this message is in error, try again later.
    I only have the problem with one unsealed MP.
    I can delete other sealed MPs and import them again. So I hope my environment with DB is working well.
    I also have deleted all overrides for this pack (in the same MP/xml because it is unsealed), restarted the DB-Server and the SCOM Management Server and also started the SCOM console with switch "/clearcache". All without success
    Any idea how I can remove this MP from my SCOM environment.
    Remark:
    I tried the idea from AndreasZuckerhut
    http://social.technet.microsoft.com/Forums/systemcenter/en-US/166c3560-c3ae-4510-8e25-1b6f1b57e3bc/unable-to-delete-mp-in-scom-2012?forum=operationsmanagermgmtpacks
    created an own MP with the same ID but a newer version and started the "Import Management Pack"  from the SCOM -Management GUI.
    This time I got the Import-error  called  "The transaction log for database 'OperationsManager' is full due to 'ACTIVE_TRANSACTION'.  I also see the same eventlog entry 9002 on the SQL-Server System.  Could this be also an hint to
    the upper problem of an failed deletion of an MP?  A guide how to solve this is on
    http://www.codeproject.com/Articles/380879/About-transaction-log-and-its-truncation-in-SQL-Se . But I not tried it yet whether it solves the problem. I will ask an SQL expert first and will note the result here later. 

  • What is the right process for moving system to another plant

    Dear Guru,
    I have below scenario which i would like to understand what should be the right process to deal with it..
    Organization Structure.
    Company code: C500
    Business area : 500A
    Plant A500 and S500 which is under the same company code and same Business area.
    Storage location: SW01 and AW01 which are physically same location address
    I have this scenario where the user have a PO under Plant S500 which already GR and IR and the physical goods is currently placed in Storage location SW01.
    But the user realized the Material should be created under Plant A500.
    For the above case, can anyone please advice me what should be the better process instead of reversal the IV/GR/PO? and what is the right process for MM and considering also from the finance point of view?
    Thank you very much,
    Regards,
    CheeWee

    Hi
    It is the configuration issue. SOmetime it happens when you copy the Reference plant to your Plant.
    Change the setting and make it both Qty & Value if you really want to manage the stock qty with value then proceed.
    Valuation area is nothing but a Plant.
    karthik
    Edited by: Karthik on Jul 25, 2011 1:23 PM

  • What is the right charger for a MacBook Pro 13"  mid 2009 model?

    What is the right charger for a MacBook Pro 13" mid 2009 model? I have two chargers for two different Mac and don't know which is  thankswhich. I'm really looking for specific details such as voltage/watts and all the rest to idenify my charger.  A link to where to web page where I could purchase the correct charger would also be very useful. Many thanks.
    All help much appreciated. THANK YOU

    Both power adapter I have are different (at the magnet end) from the one in link.
    Earlier adapters have T shaped connectors, which Apple later changed to the L shape, presumably to make them more abuse-proof. Either one is fine and the one you are using will not damage your Mac.
    Retina MBPs and new MBAs use a completely different MagSafe 2 connector which will not fit (without an adapter).

  • What are the right names for the 2 OHS?

    Hi,
    Currently we have 2 options for an HTTP Web Server for APEX:
    - An Oracle HTTP Server (OHS) from the database companion CD.
    - An Oracle HTTP Server (OHS) from the Oracle Application Server.
    The first OHS is based on Apache 1.3.x and the second on Apache 2.0.x.
    What are the right way to reference them so people know what your are talking about? In the manuals they are just called OHS but since they are not the same I would like to distinguish them some way. What do you call them?
    Regards Pete

    OK now I think got it:
    OHS from the database companion CD and from the Application Server are both based on an Apache 1.3.x HTTP server.
    On the Oracle Application Server companion CD is an OHS based on an Apache 2.0.x HTTP server. This release does not contain the mod_plsql module an can therefor not be used for APEX.
    Regards Pete

  • What's the right way to delete an entire backup ?

    I've had two Macs doing wireless Time Machine backups to one Time Capsule.
    Question: I got rid of one Mac, and want to delete its backup entirely (but leave the other computer's backups untouched). What's the right way to do it?

    Bob Timmons wrote:
    Jespes, welcome to the discussions!
    Open your hard drive. Your Time Capsule icon should appear under the SHARED heading.
    Click on the Time Capsule and a folder will appear to the right.
    Double click the folder and you should see a xxxxxx.sparsebundle file for each computer that has been backing up.
    Click on the xxxxx.sparsebundle file that you want to delete to highlight it and then click the gear shaped icon just above. Select Move to Trash. (Do not drag the file to the Trash as this will not work).
    Be careful, as the file will be deleted instantly and you will not be able to retrieve it.
    many thanks!

  • What is the right way to move a directory to another drive?

    When I move a directory to another location using drag and drop in the Elements 11 Organizer folder tree most, if not all, of the images become unlinked. What is the right way to move a directory and have the image paths updated in the Organizer database? Thanks.

    Bazsl wrote:
    When I move a directory to another location using drag and drop in the Elements 11 Organizer folder tree most, if not all, of the images become unlinked. What is the right way to move a directory and have the image paths updated in the Organizer database? Thanks.
    That's something I just did successfully one hour ago...
    I suppose your are in the 'folder' view with full folder tree, not in the 'My folder' view which only shows the lower subfolder level recorded in the database.
    Do you try to move a folder with its subfolders ?

  • What's the right way to add a swipe handler to a DataGrid?

    H All:
    What’s the right way to add a swipe handler to a DataGrid?
    (Target = Android, AIR using Flash IDE)
    Adding a handler to the DataGrid works; but (as expected) it only works on  the datagrid itself. Like if you swipe on the background before rows are fully  added. Adding columns over the datagrid, prevents the datagrids’ swipe handler  from firing.
    Trying to add a swipe hander to the columns themselves, results in the  below error.
    //  Below code fails with
    //  1061: Call to a possibly undefined method addEventListener through a reference with static type
    //   fl.controls.dataGridClasses:DataGridColumn.  So ... DataGridColumn doesn’t support addEventListener...
    There must be a better way(?).
    Thanks
                import fl.controls.DataGrid;
                import fl.controls.dataGridClasses.DataGridColumn;
               // Works, but only on the grid itself; as when the rows do not  fill the space tor the datagrid.
                myDataGrid.addEventListener  (TransformGestureEvent.GESTURE_SWIPE, swipeGridHandler);
                var c1:DataGridColumn = new DataGridColumn("Notes"); 
                c1.width = 90;
                c1.cellRenderer = CenterAlignCell;
                c1.addEventListener (TransformGestureEvent.GESTURE_SWIPE,  swipeGridHandler);

    Adobe list of properties and methods:
    http://help.adobe.com/en_US/FlashPlatform/reference/actionscript/3/mx/controls/dataGridCla sses/DataGridColumn.html

  • What is the right  way to display a table in Java web dynpro using a node.

    Hi experts,
      I am trying to show a node of cardinality 0...n as a table in an adobe form in Java web dynpro. But its not showing it properly. Can anybody please tell me what is the right way to display a table on adobe form using a node of cardinality 0...n or 1...n in Java Webdynpro.  In ABAP webdynpro, we can drag and drop a node of cardianlity 0...n or 1...n to  show as a table and it works fine. Is the same possible in Java webdynpro also. Please help.
    Thanks and Regards.
    Vaibhav Tiwari.

    Please refer to my post.. you will get the answer
    Dynamic Table -  same data repeating in all rows
    Special care should be taken in designing the context for table attribute.
    The attribute type singletone also plays a important role. I have this doubt from the beginning when you have reported this problem for the first time but finally you marked it as solved so i thought there might be some other issues but again when you reported that again i did some analysis.
    Now coming to final solution :
    For designing a table in adobe interactive form you have consider following
    You have to design the view context upto three level, I am explaining you the properties
    PDFDataSource (Parent Level1) - Cardinality 1:1 - Signetone -True - This is assigned to datasource
    TableList (Parent Level2) - Cardinality (1:1) - Signetone -True
    TableWrapper(Parent Level3) - Cardinality (0:n) - Signetone -True
    TableData (Parent Level4) - Cardinality (0:1) - Signetone - false (This is the main point)
    Then under TableData value node, you have to put all your table attributes.
    This Value Node name can be anything but hierarchy should be same as I have mentioned above.
    Please try out these steps and get back to me if you have any doubt.

  • What is the right way to connect the adapter to my macbook when charging?

    what is the right way to connect the adapter to my macbook when charging.
    is it connect the magsafe connector first before plugging the adapter to the outlet? or the way around? or both ways will do?
    what if i'm using a surge protection with a on/off button, can I just turn the surge protector extension on and off without disconnecting the magsafe connector and adapter plug from my laptop when i'm not using it?
    thank you very much

    If there is any arcing it may be because the adapter is dirty. It is best to plug in the wall wart then attach the magsafe to the MacBook. As GfulDedFan mentioned this reduces the chance of power surging the MacBook. I have done mine this way since he day I bought it and have never had an arc. I keep it clean to reduce the chance of this happening. The following will help in the care of your supply.
    Apple: Use and cleaning of MagSafe power connector

  • I would like to replace the hard drive cable for a 13" mid 2010 macbook pro.  What is the right model of the hard drive cable?

    i would like to replace the hard drive cable for a 13" mid 2010 macbook pro.  What is the right model of the hard drive cable?

    https://www.ifixit.com/Store/Parts/MacBook-Pro-13-Inch-Unibody-Model-A1278-Mid-2 009-Mid-2010-Hard-Drive-Cable/IF163-013-1
    Apple Part #: 922-9062, 821-0814-A

  • What is the latest service pack in pi 7.0?

    hi,
    may i know
    1. what is the latest service pack in pi 7.0 version ?
    2. what is the main difference in xi 3.0,pi 7.0,pi 7.1 versions?
    thanks in advance

    Latest patch details and its release notes information available at below link
    For XI 3.0..latest is SPS21
    http://help.sap.com/saphelp_nw04/helpdata/en/cf/9844428e9cbe30e10000000a155106/frameset.htm
    For PI 7.0 latest patch is SP14
    http://help.sap.com/saphelp_nw70/helpdata/en/dc/369142f195675ee10000000a155106/frameset.htm
    Gaurav Jain
    Reward Points if answer is helpful

  • What are the right content conversion parameter in this receiver ?

    Hi experts,
    Can someone help me with setting right Content conversion parameter in the Receiver of File adpater(FCC).The output file must be fixed length text file.
    Here is the receiver structure:
    <Recordset>
        <Header>
           <f1>01</f1>
           <f2> </f2>
           <f3> </f3>
        </Header>
         <Body>
            <SubBody1>
                  <field1 />
                  <field2 />
                  <field3 />
                  <field4 />
                  <field5 />
            </SubBody1>
             <SubBody2>
                  <field6 />
                  <field7 />
                  <field8 />
                  <field9 />
                  <field10/>
            </SubBody2>
         </Body>
        <Trailer>
            <f1>03</f1>
            <f2> </f2>
            <f3> </f3>
       </Trailer>
    </Recordset>
    Also Body can occure multiple times in the file but still will have this structure...Header and Trailer can occure only once in file.
    What are the right content conversion perameters in this case?
    Appreciate your help asap!T
    Thanks
    Jon

    <Recordset>
        <Header>
           <f1>01</f1>
           <f2> </f2>
           <f3> </f3>
        </Header>
         <Body>
             <SubBody>
                  <field1 />
                  <field2 />
              </SubBody>
              <SubBody>
                  <field1 />
                  <field2 />
              </SubBody>
              <SubBody>
                  <field1 />
                  <field2 />
              </SubBody>
            </Body>
        <Trailer>
            <f1>03</f1>
            <f2> </f2>
            <f3> </f3>
       </Trailer>
    </Recordset>
    if this is the input structure then FCC goes like this ....
    Recordset:Header,Body,SubBody,Trailer
    Header.fieldFixedLengths – 10,20,30.. (based on you are structure fixed lengths)
    Header.endSeparator - 'nl'
    SubBody.fieldFixedLengths – 10,20,20  (based on you are structure fixed lengths)
    Body.endSeparator - 'nl'
    Trailer.fieldFixedLengths – 10,20,30….(based on you are structure fixed lengths)
    Trailer.endSeparator - 'nl'
    We might have to try out SubBody.endSeparator - 'nl' if Body.endSeparator - 'nl' does not insert a new line after each body record.