When I loaded labview 8.5 my pcmcia device stopped talking.

The system recognizes the device, but will not communicate with it. Somehow the port communications are now dead. I unsitalled LABView and the problem still persists. Prior to the installation the PCMCIA device always worked flawlessly and it contiues to function normally in other computers. This is a custom OEM device developed by my company. Any suggestions as to how i might regain communications?

When you installed LabVIEW 8.5, were any of the device drivers installed?  If so, which drivers?
-Bob

Similar Messages

  • Recently when I load a safari page it almost immediately stops responding. I haven't had any problems until recently.  What's going on?

    Just downloaded MacKeeper onto my 2011 MBP. Suddenly when I open safari, every page stops responding almost immediately after loading. The pages load from the bookmarks, so I know that the connection is good. Once a page hangs I can open another page, which then also hangs. I'm working through FireFox now but I'd really like to resolve this problem. Any suggestions>

    HI Doug...
    MacKeeper is the problem. Your Mac does not rrequire a third party so called, "cleaning" utility. It will do more harm than good as you have already experienced.
    Follow the instructions here > Uninstalling MacKeeper
    Results of an ASC forum search for MacKeeper >  Community Search: Apple Support Communities

  • When I loaded the security update my iCloud email stopped getting sent to Apple mail...only to iCloud on the web.  What to do?

    When I installed the security update my iMac sent all my iCloud emails to iCloud mail on the web and not to Apple Mail where my main email address is and where I like to work.  What to do?

    Quit Mail, the run Repair Disk Permissions at least 2x in Disk Utility. Restart the computer in Safe Mode. Then restart normally and test, if the problem persists please post back.

  • Why does LabVIEW sometimes hang when DLL loads into memory?

    I'm calling a third party DLL from LabVIEW 2010.  LV occassionally hangs (Not Responding) when either loading the DLL into memory or when closing my main VI.  When it doesn't hang, it communicates with the DLL seamlessly.  When I try to build an Application (exe), LV always hangs during the build at the point that it is saving the main VI (the scroll on the builder moves until it says "Saving main.vi").  Any insight into what needs to be done to the DLL (or VI) to resolve this issue?

    What does the DLL do? One cause of this could be to try to load/unload other DLLs in PROCESS_ATTACH or PROCESS_DETACH of DLLMain. Microsoft has in many places said that doing this is highly unsafe and asking for all kinds of troubles, since the DLL loading is not fully reentrant.
    Another possibility would be incorporation of ActiveX components that use some form of RPC mechanisme to communicate with out of process ActiveX/OLE components. The necessary RPC proxy hooks into the calling processes message loop and that is a delicate piece of code in LabVIEW. Even when the DLL does not use ActiveX itself, it might employ some message hooking on its own and mess up things in a way that Windows and/or LabVIEW get confused.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Bring Excel 2007 to the front when called from LabView v9 in Windows 7

    I am building a duplicate system using Windows 7, LabView v9 and Excel v2007.  The original system used WinXP, Excel 2007 and LabView v8.6.  The issue is that the original system was able to bring Excel to the front when called from Labview using the property node -application-> visible.  This new configuration runs Excel, loads the data, runs the macros but does not bring Excel to the front.  The icon blinks in the Win7 taskbar and when selected displays over LabView.  If I minimize the Labview window, Excel is there.  This leads me to conclude that Excel is visible, as requested but will not come to the front until selected from the taskbar.  The only differences, besides the versions, is the original system template files used the .xls extension in and was run in Excel in compatible mode.  At the customers request, the new system uses the .xlsm extension on the Excel template files.  I have tried using application.visible = True in the macro as well.  Could be a setting in Labview?  Could be a setting in Excel? Could be .xls vs. .xlsm? Or an issue with Windows 7 and the newer version of Labview. 
    HP workstation - Labview v9 - Windows 7 - Excel 2007 sp2
    Thank you in advance
    Stephen
    Solved!
    Go to Solution.

    I will try the windowstate change.  Were these done in succession? (i.e. property node -> property node -> property node) Or were they done along the way such as call the ActiveX open and a property node then in a worksheet modification area etc. so there was some time between calls? 
    I am not sure about the API since the discussion there is with regard to DDE.  (Taken from the link document:  If you want to call a DLL that contains ActiveX
    objects, use the Automation
    Open VI with the Property
    Node and the Invoke
    Node.).  I am calling Excel as an application not as a library call unless I am mistaken, which I could certainly be.  Are you thinking that once Excel is active through the Automation Open VI that a DLL call to set the application visible would work?  I may be trying this already but in Excel through the use of the macro I call from LabView.  It contains application.visible = True at the beginning before reading files and plotting data.  
    I may try sprinkling Property node with application->visible in various locations in the LabView diagram as I do update cells after the call to the plot macro.  The puzzle for me is the blinking Excel icon in the task bar.  This means active and running but not visible or something wrong as well.  There are a few #VALUE cells if not all test in the system are run.  Again not a problem in Excel 2007-WinXP-LV8.6
    Thank you again one and all.

  • Strange crash with Intel FFT in Windows XP x64: only when first starting LabVIEW and opening VI, not when opening VI by double-clicking

    When I use the Intel FFT libraries(MKL), I seem to have a strange crash whenever I start allocating the Intel DFTI descriptors. I call a DLL from LabVIEW 8.2.1, in which these functions are used. I am working on Windows XP x64. This seems like a bug which was present in these libraries, but I got the libraries where the bug was resolved.
    The strange things is that, when I open LabVIEW and then open the VI, LabVIEW crashes from the moment I allocate an Intel Dfti descriptor. But when I just double-click the VI and open it this way, I can run the VI without a crash! I already removed the DLLs in \Program Files (x86)\National Instruments\Shared\MKL\MKL70 to see if they were the cause. But even without them, I still get the crash.
    I know there was a strange crash in the previous version of Intel MKL when calling a DLL and allocating this type of descriptor, so it seems like somewhere LabVIEW still uses old versions of some of these DLLs. But even then, can this explain the difference in behaviour between opening the VI through LabVIEW or directly? And if so, were could I find these DLLs? I've already searched from them everywhere.

    Update:
    - Opening the single VIs directly by double-clicking indeed solves the crash: from then on I can run all VIs using the libraries without any problem. So LabVIEW must do something strange when it is opened.
    - Linking my DLLs statically against the Intel libraries ALSO solves the prolbem. So this seems to indicate LabVIEW loads some dynamic library which screws up everything. But only on x64 systems . This bloats my DLL, but currently I do not see another work-around.
    Anyone has any more ideas? Otherwise I can always submit some test case to LabVIEW support.

  • Load Labview runtime engine with matlab platform

    When I use labview DLL on matlab platform it loads labview runtime engine.
    Once I use "close all" command of matlab, labview runtime engine is not available any more so I want to reload it.
    How can I do this?
    If I run the DLL again an error is occurred.
    Best regards,
    Nir

    Hello Nir,
    I recommend contacting MathWorks for assistance with the exact functionality and results of close all. Based on online documentation for calling DLLs in MATLAB, you should use unloadlibrary to remove the LabVIEW DLL from memory instead of close all. If you use this method, are you able to load the LabVIEW DLL (using the loadlibrary function) and call it successfully from MATLAB?
    MATLAB® is a registered trademark of The MathWorks, Inc.
    Regards,
    Andrew Brown
    Applications Engineer
    National Instruments

  • Field Point 4.0.1 will not load LabView Drivers

    When I load Field Point 4.0.1, it does not load the LabView Feild Point VIs.

    Dusty,
    What version of LabVIEW are you using? FieldPoint 4.0.1 came out before LabVIEW 7.1, so it will not recognize a LabVIEW 7.1 installation. Likewise, FieldPoint will not support LabVIEW versions that are too old. You can over-ride the installation parameters by running a custom installation of FieldPoint 4.0.1 and choosing the LabVIEW installation that you want. Please note that if your version of LabVIEW is older than supported, the VI's will not work. If you have LabVIEW 7.1, the VI's should work but you will miss out on some of the FieldPoint 4.1 functionality for LabVIEW 7.1.
    Regards,
    Aaron

  • How do you prevent the organizer from mixing the order of pictures when down loading off the memory card?

    @How do you prevent the organizer from mixing the order of pictures when down loading off the memory card?

    This sounds like you are using Photoshop Elements, and the Photoshop Elements forum would be best at answering that.
    Photoshop Elements
    Gene

  • TS2755 I am trying to find a message from 2012 and when I load previous messages it only goes back so far then the program quits and sends me to the home ( main) screen. How can I find the message and get around this?

    I am trying to access a message from early 2012. When I load previous messages It will only go back to oct 2012 and then the program stops and kicks my to the home page. Anyone know how I can get to the message? Thanks.

    Try Spotlight Search
    1. From any Home screen page of iPad, drag your finger down anywhere on the center of Home screen.
    2. Spotlight search will now appear and you can search for apps, texts, or any other content you'd like just as you did on previous versions of iOS.

  • How to open List when Page loads in SharePoint Hosted App?

    I  want to create an app same like InstantPracticeManager by InstantQuick.
    Now I want to know that in a SharePoint Hosted App How can I show the Whole List in a page. 
    Here I have added one image:
    Here there is one list and there are 4 views of that list.
    Now the App will be like when I load the page It will show like the image above. Now how can we show the list like this in sharepoint hosted app?
    I want the same scenario which is shown in the following blogs:
    http://sp2013.blogspot.in/2012/08/use-list-view-in-sharepoint-2013-apps.html
    and
    http://www.sharepointnutsandbolts.com/2013/08/working-with-web-parts-within.html
    where they add a list to an app
    Can any one suggest me the idea? I am bit confused.
    thanks in advance.

    Hi,
    According to your post, my understanding is that you want to show the different list view in a page in SharePoint Hosted App.
    We can use jQuery and cross-domain library to achieve it.
    The following articles for your reference:
    Adding a Tabbed View to A Web Part Page Using jQueryUI
    http://sympmarc.com/2011/11/09/adding-a-tabbed-view-to-a-web-part-page-using-jqueryui/
    How to: Access SharePoint 2013 data from apps using the cross-domain library
    http://msdn.microsoft.com/en-us/library/office/fp179927(v=office.15).aspx
    SharePoint 2013: Get list items by using the cross-domain library (JSOM)
    http://code.msdn.microsoft.com/office/SharePoint-2013-Get-items-d48150ae/view/SourceCode#content
    Thanks,
    Dennis Guo
    TechNet Community Support
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact
    [email protected]
    Dennis Guo
    TechNet Community Support

  • "unable to load labview project" in Deployment Machine

    Hi all,
    well the Deployment Target works fine on Development machine
    But has problem Loading on the Deployment System     "unable to load labview project"
    has anyone had similar issues  and  ound a soln.
    NI Support  has not responded yet to the solution.
    Attachments:
    unabletoload.PNG ‏17 KB

    Hi aparab,
    I think I will need more information to solve this issue.
    You told "NI Support  has not responded yet to the solution." Do you already have a service request number of the NI support?
    Can you post your project? Which RT-target do you use? Which hardware?
    You can also post a MAX report of you windows computer and one of your target:
    1. Start -> Programs -> NI MAX
    2. File -> create protocol -> choose technical support and my system (development computer) -> next -> next -> choose path -> next -> finish.
    3. File -> create protocol -> choose technical support and your RT-target (real-time system) -> next -> next -> choose path -> next -> finish.
    Best regards
    Suse
    Certified LabVIEW Developer (CLD)

  • HT1711 When I load one of my own CD's onto itunes, it creates separate albums for each unique pairing (ie: singer/composer or singer/orchestra). How can I keep all the cuts together on one album?

    When I load one of my own cd's onto itunes, it creates separate albums for each unique pairing (ie: singer/composer or singer/orchestra). I end up with
    the cuts scattered over several albums.  How do I keep all the cuts on an album together rather than divided between several albums? I'm brand new with this technology, so I need your information in simple terms.  Thank-you.

    Generally all you need to do is fill in an appropriate Album Artist. For more details see my article on Grouping Tracks Into Albums, in particular the topic One album, too many covers.
    The site could do with updating as some options have changed with iTunes 11, but the principles are the same.
    tt2

  • How do I turn off background ni file activity when not using Labview? files such as nimxs.exe, nipalsm.exe, nipalsm.exe, nisvcloc.exe, nicitdl5.exe

    How do I turn off background ni file activity when not using Labview? I use labview rarely, and I also use my computer for demanding multimedia applications, including multitrack digital audio recording. I need to reduce as much background activity as possible, and taking a look with task manager I see files such as nimxs.exe, nipalsm.exe, nipalsm.exe, nisvcloc.exe, and nicitdl5.exe running even when I haven't used Labview (8 I believe). These files run even after I right click the NI icon on the lower right and turn off the application. I would like the computer to boot up without these files, and for the necessary files to be activated only when I start the program.
    Can this be done or do I have to remove labview from the system to improve performance?
    Thanks

    Hello, those processes are part of running NI services that start when Windows boots.  These processes serve varied purposes and stopping them can have undefined and unknown consiquences for your NI products.  These products run at "normal" priority meaning that they should be preempted by any process running at a higher priority which I would expect your other application to be doing given their time sensitivity.  That being said, in Windows XP (I can't speak for other OSes), you can lower their priorities even greater through task manager (right click the process»set priority) to further remove them from contention for resources.  If you want to prevent them from running you can set the service startup type to "manual" in Control Panel»Administrative Tools»Services.  Right click the process go to Properties and Under the General tab choose Startup Type»Manual.  This will start up the processes only when something directly starts it up.  LabVIEW will start these processes up as it attempts to use them.  When you shut down LabVIEW you will need to manually shut down these processes through task manager.  Again, doing this can cause problems with your NI products on your system and it is not advised.
    Travis M
    LabVIEW R&D
    National Instruments

  • HELP, PLEASE.. I'm looking for a App that I can install on both my iPad and iPhone, then when I load a document, picture, or anything on that app on iPhone or iPad, it will Sync with the other Device so both devices will end up with the same file .

    HELP, PLEASE.. I'm looking for a App that I can install on both my iPad and iPhone, then when I load a document, picture, or anything on that app on iPhone or iPad, it will Sync with the other Device so both devices will end up with the same file ...

    iCloud Drive: https://www.apple.com/icloud/icloud-drive/
    Dropbox: https://itunes.apple.com/us/app/dropbox/id327630330?mt=8
    OneDrive: https://itunes.apple.com/us/app/onedrive-for-ios/id477537958?mt=8

Maybe you are looking for

  • Problems with iWeb and mobile me

    Ciao everyone, I've been having a ridiculous amount of problems with my mobile me account and my iweb. 2 weeks ago I was fine with my iweb and mobile me but all of a sudden my iweb would say it publish but it really doesn't publish. The I went to the

  • ICR proces 003: data reconciliation runtime

    Dear all, we are implementing SAP ICR process 003 for both customer/vendor open items and GL open items and have come across the following issue: If a user runs tcode FBICR3 for a period in which no data exist (yet) in table FBICRC003A, tcode FBICR3

  • How to convert image to line art

    I'm trying to get a grey scale image to be just plain black and white, no grey tones. Anyone know how I would do this? Thanks.

  • Receiving channels 225 et al

    Not sure if this question is related to the massive Multicast thread earlier (much of which is all g(r)eek to me, I'm afraid) but I'm surprised that I still can't receive the channels 225 and upwards. I still get a message saying that I do not have a

  • Unable to see User eixt macro in SCM 4.1 - When creating a Collective Macro

    Hello : we are SCM 4.1. We have a need to run 4 macro in a sequence.  I felt that I could create a collective macro and list the macro's.. The macro are user exit macro's. and I am unable to see them in the drop down list.. tried to search OSS Notes