Where is the Running Time Indicator?

Where can I find the Running Time as I watch a project? I only see the seconds on each clip but no total running time.

Where can I find the Running Time as I watch a project? I only see the seconds on each clip but no total running time.
Karsten may have interpreted your question literally. You asked "where can I find the Running Time as I _watch a project_" (underline is my emphasis). I think you may have meant viewing the elapsed time when skimming through and editing your project.
Go to iMovie>Preferences in the Menu and select the General tab. Check (tick) the box labelled "Display time as HH:MM:SS:Frames". Now, from the Menu, select View>Playhead Info. When moving through your project, in the black panel that moves with the playhead, you will see the elapsed time down to the frame level.
Unfortunately, as Karsten reported, the elapsed time does not show up when simply "playing" the project.
John

Similar Messages

  • Is it possible to choose the serial port if only the run time engine is installed

    I have an application, which communicates over the serial port. When I use the full version of Labview I can change the serial port without any problem from Com1 to Com2 (similar to the example “Hardeware input output -> serial -> Labview serial vi"). When I build an application and try to run this program on a computer where only the run time engine 6.1 is installed, it is not possible to choose the serial port. Since there is no “Measurement and Automation Explorer” available on the run time engine and no directory C:\VXIpnp is created, when the run time engine is installed, I do not see a way, how I can satisfy the computer with the information it needs for configuring
    the different ports. Any suggestions?

    Hi Daniel,
    Before LV6.1 there was LV5.1 In LV5.1 the way to Spedify a resource was to use a string control with correct VIsa Resource Class identifier. For eg. "GPIB0::11" or "ASRL1::INSTR". With Introduction of VISA Resource Name Control and linking with MAX, These names are Available from Pull Down List and Can be Aliased, meaning ASRL1 which is Serial Port 1 can be called COM1 and so on. However the old method still works with all 6.1 Controls. Only thing is you have to make sure you Dont Conflict the Class Names ie Use "GPIB::.." instead of "ASRL..." when addressing Serial Port VI's.
    To solve your Problem I would Build a Menu ring with COM1 to COM4 in the Pull Down List.
    Next, If I use the Traditonal Serial Port VI wich accepts the Integer as Seria
    l Port #. I just Wire the Menu Ring to this VI.(Remember COM1 is 0, COM2 is 1 for this VI)
    If I use VISA Config Serial Post. I build an Array Constant with Corresponding VISA Class Names So in our case a String Array Constant of 4 elements "ASRL1::INST" to "ASRL4::INST". I Use Index Array Function With the Index Wired to my Menu Ring. The Array Input Terminal Wired to the Array Constant. The Output of this Array will be correct Visa Class Name Based on slection of my Menu Ring. I can Wire this as Input to my VISA Config Serial Port Vi.
    I have attached a Small VI to Illustrate this.
    Drawback: You must Predefine what Ports you will Want to Use. Basically you define all the cases.
    I hope this Answers your Q!
    Good Luck
    Mache
    Good Luck!
    Mache
    Attachments:
    Serial_Port_Select.vi ‏36 KB

  • Display Progress Indicator in the Run Time

    Hi All,
    How do display Progress Indicator in the Run Time for a JSF Page using ADF components?
    Regards
    Santosh

    I have similar problem.
    Basically my page do search in the database which takes some time. so when search starts I would like to display the progress indicator or some thing which will show some processging is going on in background. Once it completes the background processing, the same page displays the result. At this time I want to hide the progress indicator.
    Is there any way to do this. I am using EA17 with JDev.

  • Path where to install the run time engine (on Linux)

    I have a cluster of Linux computers where I would like to run compiled LABview (8.20 at the moment) applications build
    with the application builder.
    Therefore I would like to install the LABview run time engine on a NFS mount file system seen from each computer.  But
    the installation procedure of the run time engine does not propose to
    choise the installation directory, but force the installation
    in  /usr/local/lib.
    I try to workaround this problem and have copied the /usr/local/lib/LABview.8.2 directory to my NFS filesystem and
    made the 'necessary' links.
    Unfortunatly it doesn't run and  fails because  the
    liblvrt.so.8.2 library  can not access patched versions of the
    libOSMesa.so.4
    and libGL.so.1 librairies but uses the standard ones in /usr/X11R6/lib.
    Even by setting my LD_LIBRARY_PATH correctly to access the patched librairies versions it does not run because the
    liblvrt8.2 library seems to be  linked with the following
    'rpath'   (given by the command 'strings liblvrt.so.8.2 |
    grep patchlib')
    $ORIGIN/LabVIEW-8.2/patchlib:$ORIGIN/patchlib:/usr/X11R6/lib:/usr/lib:$ORIGIN:$ORIGIN/LabVIEW-8.2/linux:$ORIGIN/linux:$ORIGIN/resource
    which prevents to access the patched librairies versions if the $ORIGIN is not set. Therefore I tried to set $ORIGIN as an
    environment variable but it doesn't change anything.
    Therefore my question is: Did somebody have already had this type of problem,  what is $ORIGIN and how I can set it ?
    Thanks in advance.

    Sir,
    Please could tell me the distribution you use ?
    Cordially,
    Pierre R...
    Certified LabVIEW Developer

  • Can we load and unload the files in the run time?

    Can we load and unload the files in the run time?
    For example there are four files named "test1.h & test1.c" and another set "test2.h & test2.c" (I attached them as attachment to this post).
    test1.h contains code:
    int variable; //variable declared as integer
    test1.c contains code:
    variable = 1; //variable assigned a value
    test1.h contains code:
    char *variable; //variable declared as string
    test1.c contains code:
    variable = "EXAMPLE"; //variable assigned a string
    So here, in this case can I dynamically load / unload the first & second group of files so that the same variable name "variable" can be used both as integer and string? And if yes, how is that to be done?
    Solved!
    Go to Solution.
    Attachments:
    test.zip ‏1 KB

    What do you mean by "dynamically"?
    If you want to have a variable that either is an int or a char in the same program run, I'm afraid your only option is to define it as a variant and assign from time to time the proper data type in the variant according to some condition. Next, every time you access the variable you must firstly check which data type is stored in it, next access it in the proper way.
    If on the other hand your option or to have a run in which the variable is an int, next you stop the program and in a following run it is a char, you may have it by using some appropriade preprocessor clause:
    #ifdef  CHAR_TYPE
    #include "test1.h";        // variable defined as a char
    #else
    #include "test2.h";        // variable defined as int
    #endif
    Next, every time you want to access the variable you must proceed in the same vay:
    #ifdef  CHAR_TYPE
      variable = "string";
    #else
      variable = 1;
    #endif
    Does it worth the effort?
    Additionally, keep in mind that this "dynamical" approach can work only in the IDE, where you can properly #define your CHAR_TYPE or not depending on your wishes: when you compile the program, it will have only one #include depending on the definition of the macro.
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • In LV6.1, can I get the run-time menu refnum of a VI from the VI Path?

    Actually, for any version of LabVIEW, can I get the run-time menu refnum from the VI Path (or the VI reference)?
    Thanks!
    Enrique
    www.vartortech.com

    I just thought of a workaround...you could have a Menu Bar Ref indicator on your main VI front panel.  When your VI runs, you could have the Current VI's Menubar function wire the refnum into that indicator.  Then, in your subVI that has the VI reference, you could use VI Server to read the value of that indicator, then cast the value into a refnum wire, then you'd have access to the menubar reference in the subVI without having to pass it in to a subVI terminal.  Would that work?
    Oh, another simpler idea would be to simply wire the Menubar reference into a global, and read that global in the subVI.
    -D
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • How to specify a different directory for the Run-Time Engine?

    With LV 7.1 it's become even more difficult to create installation sets in third-party tools without having to include the full run-time engine separately.
    If you use any of the advanced analysis VIs you have to install the run-time engine (no use in including files in the same directory as the built application) and if you do and you use the old serial VIs you get a problem because the application will load the run-time from the main run-time installation and then look for serpdrv in that directory, not in the application folder...
    So - being forced to use the installer builder in the application builder and include the run-time engine in the installation kit I wonder whether it is possible to specify where the run-time should be installed?
    By default it will go in a directory called National Instruments in the program files folder, however that is not ideal due to the fact that the users have no relation to the fact that our application needs something from NI...and may end up deleting the directory ("National Instruments? - what do I need that for...let me delete it...). We would like to be able to specify that the run-time is installed silently in a directory named with our company name instead.
    MTO

    When you create the stand alone, in options you can actually set the temp directory and default directory. You can change it there OR in goto options and check for libraries/directories. You can change it there too.
    Kudos always welcome for helpful posts

  • Building an Application in Windows to be used in Linux (with the Run-Time Engine)

    Hi All,
    I have an LabVIEW project I have developed in a Windows environment.  I can create an Application (.exe) using the Build Specification -> Application Builder which works fine on the development platform.
    I now want to distribute the application to a Linux Environment.  The OS is openSUSE v10.3 (with GNOME).  I have downloaded the two rpm files needed for the run-time engine and installed them, as per here:http://digital.ni.com/softlib.nsf/websearch/97E14BA3E0C14A89862572C300567733?opendocument&node=13207...
    Now, the question is; how do I create an Application in Windows which can be used on the Linux Box?  According to the Application Builder instructions, it's simply a case of removing the .exe extension in the Target File Name options, however, this gives an error "Invalid Extension."
    If I do create an exe and manually remove the extention is doesn't work on the Linux enviroment (typing ./application).
    Has anyone had experiance of this?
    Many Thanks for Any Help,
    Oliver
    Windows XP SP 2
    Labview 8.2.1
    openSUSE v10.3 (with GNOME)
    LabVIEW Run-time Engine Version 8.2.1 for Linux

    The cross-platform nature of LabVIEW refers more to the code than to the executable.
    LV (given the appropriate development version) can compile the same source code into a Windows (using LV for Windows), Linux (using LV for Linux) or Mac (using LV for Mac) program.
    This means you will still have three versions of your program, one for each platform.
    If you want to distribute VIs (without block diagrams), you will also need different versions of these as without the block diagram, they cannot be re-compiled for a new platform.
    Shane.
    Say hello to my little friend.
    RFC 2323 FHE-Compliant

  • Report layout in the run time

    i have bilingual system
    i want to change the layout of report from right to left or opposite as my language
    for example :
    if my language = English
    layout = left to right
    if my language=Arabic
    layout = right to left
    during the run time
    thanks in advanced

    Hi Lavanya,
    This can be the mapping error.
    Take the source payload from SXMB_MONI, copy it and paste in the 'Test' tab of Message mapping in IR.
    Check if you are getting any error or it is successful there.
    -Supriya.

  • How to know the timings of the run time of thr report

    Hi,
    Can you please tell me how to know the run time of the query , i mean how much time it took for the query to dispaly the results .
    Also we have these queries in the workbook. How to refresh the work book . is it enough if i refresh the query.
    Thanks
    Sruthi

    Hi
    How can we check in RSRT tcode?
    And how can we do i RSRTRACE?
    Can  I know the procedure.

  • Hiding url in the run time

    hi gurus,
    i am using oracle forms 10g, i have developed a form
    i am running that form it is showing in the web browser
    http://192.168.0.15:8889/frm/frmservlet/?from=test.fmx and also how to hide the back side main window i mean to say the by default window/MDii window which is shown
    at the run time.
    can i hide the '192.168.0.15:8889/frm/frmservlet/?from=test.fmx' this from other users who is running this forms by accessing my ip address while running the form.
    in fact i have already seen this hiding but i don't how to hide this
    can anybody tell me how to hide this by giving alternative name from my own..........

    Yes, this is possible. To hide the URL you will need to use HTML Frames and assign the Forms Servlet page to one of the frames. Then call your application using the frames html page. Here is the basic setup:
    1. Create a simple index.html as follows:
    <HTML>
    <HEAD>
    <TITLE>YOUR APP TITLE HERE</TITLE>
    </HEAD>
    <FRAMESET BORDER=0 rows="1, *">
    <FRAME NAME="top" SRC="top.html" FRAMEBORDER="NO"
    SCROLLING = "NO" NORESIZE>
    <FRAME NAME="bottom"
    SRC=http://HOST:PORT/forms/frmservlet?config=myAPP FRAMEBORDER="NO" SCROLLING = "AUTO">
    </FRAMESET>
    </HTML>Beware to change the HOST:PORT to your actual host and port information.
    2. Save this file in the docroot directory for the HTTP server
    3. Create a dummy empty file at the same location named top.html (To represent the upper frame)
    4. Run the URL http://HOST:PORT/index.html or simply http://HOST:PORT
    Hope this helps,
    Craig B-)
    If someone's response is helpful or correct, please mark it accordingly.

  • How to change the printer name in the User profile in the run time.

    Hi
    I am in need to change the printer name in the run time.
    Do any one hav idea about this?
    Thanks
    Karthik

    The user default settings can be changed using funtion module SUSR_USER_DEFAULTS_PUT.
    Import parameter USER_DEFAULTS-SPLD will hold the default printer name.

  • The "Null Error Stack"  that is shown in the Run time workbench

    The Data is set to flow from SAP R/3 system to target system through XI. When the data is triggered in the SAP system, the same data is getting updated in the target system database. But when i check in the Run time workbench for the same, in the active log the following error is shown
    "Received XI System Error. ErrorCode: RUNTIME_EXCEPTION ErrorText: null ErrorStack: Runtime exception occurred during mapping" and "
    The message was successfully transmitted to endpoint com.sap.engine.interfaces.messaging.api.exception.MessagingException: Application:RUNTIME_EXCEPTION: using connection RFC".
    When i monitor the same using T-code sxmb_moni, i am getting the error "Thrown: java.lang.NullPointerException".
    Can someone please explain what is this Null Pointer Exception and how can this be solved?

    Hi Lavanya,
    This can be the mapping error.
    Take the source payload from SXMB_MONI, copy it and paste in the 'Test' tab of Message mapping in IR.
    Check if you are getting any error or it is successful there.
    -Supriya.

  • Change column width in the run time

    Hi, everyone:
    I have a form with a master and a detail block. The detail block has a tabular layout. I want the user of the form being able to ajust the width of the particular column(s) in the run time by, e.g. dragging the border of the column(s) to the left or to the right. I've seen the examples of these forms, but want to know how easy would it be to implement that.
    Thanks a lot.
    Eugene.

    Hi, everyone:
    I have a form with a master and a detail block. The detail block has a tabular layout. I want the user of the form being able to ajust the width of the particular column(s) in the run time by, e.g. dragging the border of the column(s) to the left or to the right. I've seen the examples of these forms, but want to know how easy would it be to implement that.
    Thanks a lot.
    Eugene.

  • How to disable the run-time popup menu in the sequence display on TestStand Operator Interface, that allow the use to skip the test?

    How to disable the run-time popup menu in the sequence display on TestStand Operator Interface, that allow the use to skip the test?

    Hello,
                  Regarding the skip/force pass/force fail options, when I set the ControlExecFlow to True in Teststand 3.1 and 3.5, in the Sequence Editor the menu options for skip/force pass/force fail are not active for Technician but, when I launch the Operator Interface logged with Technician the options are active. The problem is that if the technician sets one step to one of these options, and change the user to Operator, the test step remains skip/force pass.
                  Is there any possibility without modifying the Operator Interface (at programming level), to reload default values of the steps when changing the user to Operator?
    Thank you,
    Best regards,
    paio

Maybe you are looking for

  • UNCAUGHT_EXCEPTION while creating Purchase Order in Extended classic SRM 7

    Hi Experts, I am getting the following message while creating Manual or SC/PO in Extended classic Scenario (SRM7.0 with ECC 6.0) Pl suggest what could be the problems. Error application is coming up. 20091130 E2001 172331 wicomp03 http://wicomp03.wip

  • Error selecting a dimension member in BPC EPM report - The given key was not present in the dictionary

    Hi, We are currently running SAP BPC 10.1 NW on Hana Version: CPMBPC  810 SP 4 SAP_BW  740 SP 9 HANABPC 810 SP 4 EPM Excel Add-in 10 SP 21 .NET 4 build 9094. On my embedded model. I have a BEX query on a aggregation level which I access in a report u

  • Documents / Cookbook on how to configure Extended Classic Scenario?

    We currently have the Classic scenario and are thinking of changing to exteded classic becuase we want to use the sourcing cockpit in SRM 7.0.  Does anyone have any good documentation on how to configured Extended Classic?

  • Help with Business Contents 7.0

    hello everyone,i need help with this question if i want to install a business content cube ok but i want bi 7.0 way how can i do that? either let me know or point me to a link. i tried to search by different keywords but i couldnot find anything. tha

  • Nokia's IM Chat is not starting

    My chat app suddendly stopped working. The last thing I remember happening before it stopped was 1 time I restarted my phone and I saw this SSOUI came up asking me to log in... which I did. Later in the day, I realized that when I try to launch Chat,