While saving the notification

Hi Guys,
I have one requirement like this when a notification is assign to an order and before save i neen to check wheather the planner groupe in the notification(iw22)in the header data  should be equll to the planner groupe in the work order(iw32) in the header data if not equll i need to raise an error message and for this i am using the user exit EXIT_SAPMIWO0_020 can any one help me how to procede further to approch this requirement
waiting for your response,
thanks in advance.
sankar

sankar,
Use field-symbols on "(SAPLIQS0)VIQMEL-INGRP" in user-exit IWO10009 (at order save) to call the notification values. Then compare then with CAUFVD_IMP-INGRP
PeteA

Similar Messages

  • Error messgae while saving the Notification

    HI All,
    We got one requirement, when we are creating the PM Notification (TC: IW21) we are assigning the already exiting PM work Order. After assigning the work order, we are saving the notification. While Saving the Notification the system should check whether the Maintenance Planning Plant (IWERK) and Planning Plant (SWERK) of Notification is same as Maintenance Planning Plant (IWERK) and Planning Plant (SWERK) of PM work Order.  If it is same then Notification should be saved else u201Cerror messageu201D should be displayed.
    Note:
    Maintenance Planning Plant (IWERK) is available in HEADER TAB of Notification or PM Work Order. That is next to Planner Group.
    Maintenance Planning Plant (SWERK) is available in LOCATION tab of Notification or PM Work Order. That is next to Planner Group.
    We are using the user exist QQMA0014 (PM notification: validitye checks during save) for this purpose. We are able to get the IWERK and SWERK value of PM work Order eassily, sine the data stored in AFIH and ILOA table (ILOA-ILOAN = AFIH-ILAON). Even we are able to get the IWERK value of Notification from VIQMEL structure before Notification saved. But we are not able to get the value of SWERK of Notification before saving the Notification because SWERK value is stored ILOA table. For accessing SWERK from ILOA table, we need ILAON from VIQMEL. The problem is ILOAN value is not avialable in VIQMEL before the Notifivation is saved.
    Please let me know how we can get this value or is ther is any other user exit from which, we can get this??
    Regards
    Ramu

    Dear Ramu,
    Can you once again come up with your querry in shot message.
    Regards,
    Kaushal rai

  • Error while Saving the report

    Hi,
    i have created some reports which are working fine,
    but now i am facing some errors while saving the files.
    Also the reports does show only one record while there are many records in the database.
    The error messages are as follows:
    REP-1051; Unable to save document to file ' F:\Database\Reports\report1.rdf '.
    REP-1070: Error while opening or saving a document.
    Please help me to find out the exact problem.
    Also tell me how can i show all the pages of Database records in a report( while one record on each page)

    As for the error while saving, you have only one possible thing to try. It it doesn't work, you're sunk.
    Assuming the report was not being newly created, i.e. that it was opened from a file on your system, then rename that file to something else (Report_001_OLD.rdf, for example). Then try to save it - Reports will think it is a new file to be saved rather than an existing file to be updated.
    Again, if that doesn't work, and if you do not have the auto-save option turned on, then you're sunk. You will have just lost all of the work you've put into that report.
    As you'll discover, Reports is not the most robust application ever written.

  • User Exit while saving the Excise Invoice in J1IIN

    Dear All,
    I want know whether anu User Exits are there while saving the Excise Invoice in J1IIN.
    The "scenario" here is as follows:
    ---I will create an invoice(Commercial) in VF01. Suppose I got a number 1234(This is Billing Document number).
    ---Now I will go to J1IIN and create an Excise Invoice by reffering to the VF01 Billing Doc Number.I will enter all the details. Then I will Save it. While saving I want to check the following aspect:
                         I want to compare the Billing Document Number and Excise Invoice Number and give error if both the numbers are not same.
    ---That is I want to see that Excise Invoice and Billng Document number should be same.
    I need your suggestion in the above scenario.
    I will definitely reward if problem is solved.
    Regards,
    Raj Kumar Reddy.

    Hi Raj,
    Here is a list of available userexits for transaction J1IIN :
    J_1I7_USEREXIT_DEPOT_BEF_SAVE
    J_1I7_USEREXIT_DUTY_IN_EXPORT
    J_1I7_USEREXIT_EXCISE_BEF_SAV
    J_1I7_USEREXIT_EXGRP_DETERM
    J_1I7_USEREXIT_SERGRP_DETERM
    hope they are of some use.
    Regards,
    Philip Johannesen

  • Error while saving the excise invoice

    Hi All,
    I am getting the following error while saving the excise invoice.
    No account is specified in item 0000000001
    Message no. F5670
    Diagnosis
    No account was specified for account type "S" in item "0000000001" of the FI/CO document.
    System Response
    The Financial Accounting program cannot process the document.
    Procedure
    A system error has probably occurred in the application you called up. Check the data transferred to item "0000000001" of the FI/CO document.
    I have read all the posts with regards to the error before, however still after doing the required settings I am getting the error. Please let me know for the same.
    Kind Regards
    Atul Keshav

    Dear All,
    The issue stands resolved please find below the required settings which need to be done.
    You need to maintain the following entries in  J_1ITRNACC table
    100 DLFC 01 CR PLAAED
    100 DLFC 01 CR PLABED
    100 DLFC 01 CR PLACESS
    100 DLFC 01 CR PLASED
    100 DLFC 01 CR PLAAT1
    100 DLFC 01 CR RG23AAt1
    100 DLFC 01 CR RG23AED
    100 DLFC 01 CR RG23BED
    100 DLFC 01 CR RG23SED
    100 DLFC 01 DR MSUSP
    Also the table J_1ITRNACC should include entries for GRPO, CAPE, DIEX, EWPO,
    TR6C with subtransaction type 01.
    We need to maintain GL Accounts accordingly in the table  J_1IEXCACC.
    If still the error persists then you need to apply the following notes.
    1018071
    978186
    1032813
    The SAP note 1032813 contains the correction for the program MJ1IINF01
    you will have to apply this manually.
    Kind Regards
    Atul Keshav

  • ERROR while saving the runtime systems(read time out exception)

    Hi e xperts
    I am configuring NWDI and assigned asll the permissions and roles to the CMS user.I created Domain,in landscape configurater
    created track and saved.
    while saving the rumtime systems the error thrown is
    com.sap.cms.util.exception.conf.CMSCCBSCommunicationException: CBS (URL http://dtlepdev:54400/tc.CBS.Appl/archiveapi2/) communication exception: Read timed out (Service call exception; nested exception is:
    java.net.SocketTimeoutException: Read timed out)
    at com.sap.cms.pcs.conf.communicator.CBSConfCommunicator.removeBuildspace(CBSConfCommunicator.java:382)
    at com.sap.cms.pcs.conf.communicator.CBSConfCommunicator.deleteCreateBuildspace(CBSConfCommunicator.java:338)
    at com.sap.cms.pcs.conf.communicator.CBSConfCommunicator.editBuildspace(CBSConfCommunicator.java:277)
    at com.sap.cms.pcs.conf.communicator.CBSConfCommunicator.createBuildspace(CBSConfCommunicator.java:168)
    at com.sap.cms.pcs.conf.core.services.SystemManagerObject.saveSystem(SystemManagerObject.java:261)
    at com.sap.cms.pcs.conf.core.plugin.DefaultTrack.newTrack(DefaultTrack.java:292)
    at com.sap.cms.pcs.conf.core.TrackManager.editTrack(TrackManager.java:208)
    at com.sap.cms.pcs.conf.manager.CmsConfManager.editTrackConfiguration(CmsConfManager.java:1002)
    at com.sap.cms.pcs.conf.manager.proxy.CmsConfProxyBean.editTrackConfiguration(CmsConfProxyBean.java:489)
    at com.sap.cms.pcs.conf.manager.proxy.LocalCmsConfProxyLocalObjectImpl0_0.editTrackConfigurationand also ..
    Unable to instantiate a Build Space administrator!
    Build Space "DTL_ETRACK_C" [bsID: 27, version: 0] [in-queue: on (privileged), out-queue: "on", processing: off]
    <null>
    [EXCEPTION]
    Buildspace DTL_ETRACK_C does not own the workspace ws/ETRACK/dtl.com_DEFAULTIME/cons/inactive/ .  It is currently not owned by any other buildspace
    at com.sap.tc.cbs.server.rt.bs._BuildSpaceValidator.checkWorkspace(_BuildSpaceValidator.java:120)
    at com.sap.tc.cbs.server.rt.bs._BuildSpaceValidator.validateWSs(_BuildSpaceValidator.java:74)
    at com.sap.tc.cbs.server.rt.bs.BSAdmin.validate(BSAdmin.java:192)
    at com.sap.tc.cbs.server.rt.bs.BSAdmin.updateState(BSAdmin.java:260)
    at com.sap.tc.cbs.server.rt.bs.BSAdminOrc.determineChanges(BSAdminOrc.java:439)
    at com.sap.tc.cbs.server.rt.bs.BSAdminOrc.validateBuildSpaceData(BSAdminOrc.java:219)
    at com.sap.tc.cbs.server.rt.bs.BSAdminOrc.act(BSAdminOrc.java:341)
    at com.sap.tc.cbs.server.rt.impl.CourteousTimer.run(CourteousTimer.java:139)
    at java.lang.Thread.run(Thread.java:534
    In cbs i checked the parametrs they are open and on..
    please suggest me on this ASAP..since 2 days i have been struggling and searched in forums..no perfect solution
    help me out
    perfect soln is immediately awarded...
    I
    THanks
    Mayu

    Hi Mayu,
    here apparently the CMS cannot communicate to CBS properly and then when CMS tries to talk to CBS using a webservice, it times out due to various reasons, see below.
    Strange, I always had this error when the CMS was on a different release like CBS and this caused the communication problem.
    Don't you have an entry in your cms log like this?
    com.sap.cms.util.exception.CMSUnexpectedException                          
    at com.sap.cms.pcs.conf.manager.CmsConfManager.newTrackConfiguration(CmsConfManager.java:666)                                                    
    Caused by: java.lang.IncompatibleClassChangeError
    at com.sap.cms.pcs.conf.communicator.CBSConfCommunicator.openConnection(CBSConfCommunicator.java:84)                                             
    Please provide me the version of the DI_CMS, DI_CBS (and DI_DTR for the sake of completeness).
    You can find this info on the ComponentInfo page.
    On 640/700 this is http://<host>:<port>/sap/monitoring/ComponentInfo
    as of 710 you find this on the "Components" tab of http://<host>:<port>/nwa/sysinfo
    I also think that this is not due to the runtime systems. I guess you have the same problem if you try to create the track without runtime systems, right?
    (The "Unable to instantiate a Build Space administrator!" is not necessarily an error, see the note:
    #1175019 - Unable to instantiate a Build Space administrator!)
    Thank you!
    Best Regards,
    Ervin

  • PSC 2510 - Wireless setup - "Error while saving the settings to the device."

    While trying to setup my PSC 2510 to be wireless I get an error message "Error while saving the settings to the device.". This comes after selecting connecting Through Network, selecting printer device, selecting WEP, entering key, and clicking next.
    PSC 2510
    Windows Vista
    Using latest sfotware from HP to install
    Thanks
    Dennis
    This question was solved.
    View Solution.

    ISSUE RESOLVED .. based on responce from PrintDoc to penn (refrence topic "C4385 Printer - Netgear DGN2000 - wireless setup".
    PrintDoc responce helped me find my problem (to reset network settings on the printer to factory) even though diffrent printer.
    Thanks

  • Error while saving the FM8 XML file

    Hello,
    While saving the FM8 XML file, an error message appears (see attached screen shot).
    Is there a solution to resolve this issue? Please suggest.

    Hi,
    This type of error is non-descript and could be caused by any number of things. It is impossible to troubleshoot from here based solely on that message. Let me ask a couple of questions, though:
    - Are you using structured FrameMaker? If so, are you using a structured app that has worked successfully before? In other words, did this just suddenly start happening to an otherwise-stable process?
    - Is there anything unusual about your layout; that is, anything other than a single text flow with graphics?
    Russ

  • Error while saving the GTC

    Hi All,
    I am getting below error message, when I try to save GTC created.
    "An error occurred while saving the information for generic technology connector S2TSI TRUSTED CONNECTOR. Check the application logs for more details. "
    Even I am getting the same error when I try to modify the existing GTC connectors.
    Can someone please let me know how to resolve this issue. I am not able to locate the log files where I need to check.
    Thanks in advance.....
    Regards
    Arun

    Hi Arun,
    what type of GTC you are creating (Flat file / Database)?
    Regards,
    Sheik

  • Error While saving the Production Order

    Dear Experts
    Pls let me know why am getting the below error while saving the production order after release..
    PSFC_STD_LAYOUT does not exist
    Message no. SSFCOMPOSER004

    Dear,
    Please check have you assigned the scheduling profile in work scheduling view of materail master?
    Then go to OPKP check the same scheduling profile where you have activited the On realese execute printing remove this tick mark and then try with new order.
    Or you can do the configuration in Tocde :OPK8 here assign the PSFC_STD_LAYOUT in forum.
    Regards,
    R.Brahmankar

  • Error while saving the excel file

    hai all,
    i had an requirement to upload customer master data through lsmw while saving the data in excel file with extension as) text( tab delimeted)(.txt) it is not saving and displaying the message as " the selected file type doesnot support workbooks that contain multiple sheets. to save only the active sheet click ok."
    regards,
    karthik

    Ensure that you have not opened any excel file or text file with similar name.
    thanks
    G. Lakshmipathi

  • Error While saving the project

    Hai sapians,
    I am using the solution manager for the first time.I am getting the error -Project save cancelled(Message no. SPROJECT345) While saving the project in the T-code-solar_project_admin. What could be the problem ?
    Thanks
    Sukumaran.E

    Hi,
    Except this I am not getting any long text. After pressing saving I am getting a POPUP asking for Enhancement (/KWCUST/) Release(620) After this I am Getting the error and there is no other text.
    But in the General Data tab I am not able to give Project Description (It gives error message  Authorization Check Error Message no. SOLAR409).
    Thanks
    Sukumaran.E

  • Error While saving the tabulator results recording(QE71)

    Hi Experts ,
    through the Tcode QE71 i'm recording the inspection points and the inspection results but while Saving the recorded results , the system is giving error as " No Orignal values " and also as "inspection Pt 99999 of the Characteristics .....is not avaialable".
    What might be the possible reason for the same. But when i'm entering the results through the Tcode QE01 all the results are saved and closed.
    Can anybody help me out of this.
    B'regards
    Krishna

    Hi,
    Can you call your web service using jQuery not in an app successfully?
    As the error message suggests, it might be an error on the server side.
    I suggest you do a simple test to check whether you can call the web service using jQuery.
    Here are two links would provide more information about troubleshooting this error for your reference:
    http://sadomovalex.blogspot.com/2013/08/return-json-from-asmx-when-call-it.html
    http://www.codeproject.com/Tips/761116/Troubleshooting-an-Issue-With-Calling-an-asmx-Web
    Feel free to reply with the test result if the issue still exists.
    Best regards
    Patrick Liang
    TechNet Community Support

  • Error while saving the routing

    frndz,
    While saving the routing the system says "Internal number assignment not possible for object ROUTING_N number range 01".How resolve this errror.......
    Regards,
    Srini

    Hi Srini,
    Please refer below,
    Use transaction OP8B, enter task list as N & then for the object Routing_N enter 01 as the intenal number assignment & then save.
    Also for internal no. range in OP62 the Ext. check box should not be selected.
    Now create a routing & check.
    Regards,
    Senthilkumar
    Edited by: Senthilkumar SD on Apr 16, 2008 2:09 PM

  • Dump while saving the project

    Hi all,
    System is giving dump while saving the changes in the project.
    Short text
         The current application triggered a termination with a short dump.
    What happened?
         The current application program detected a situation which really
         should not occur. Therefore, a termination with a short dump was
         triggered on purpose by the key word MESSAGE (type X).
    What can you do?
         Note down which actions and inputs caused the error.
         To process the problem further, contact you SAP system
         administrator.
         Using Transaction ST22 for ABAP Dump Analysis, you can look
         at and manage termination messages, and you can also
         keep them for a long time.
    Error analysis
         Short text of error message:
         Profitability segment number 0026636665 does not exist in operating conc
         ern XXXX!
         Long text of error message:
          Diagnosis
              The system discovered a serious inconsistency in the data basis of
              Profitability Analysis (CO-PA) This message should never occur in
              the course of normal operations.
              The system tried to find characteristics from the segment table
              CE4XXXX using the segment number 0026636665 in operating concern
               This profitability segment number does not exist.
              This can occur if you have deleted data from table CE4XXXX and have
              already assigned data to profitability segments in this operating
              concern.
              Another cause may be that you have changed the assignment of your
              controlling area to an operating concern. When this happens, the
              system tries to interpret the segment numbers in the new operating
              concern.
          System Response
              Do not continue processing.
          Procedure
              The data in the segment table needs to be reconstructed. It may be
              possible to re-enter the assignments to profitability segments.
              Look in OSS for notes regarding error message KE499. You may find
              information there that could help you solve the error.
              Otherwise contact your CO-PA consultant or create a problem
              message.
         Technical information about the message:
         Message class....... "KE"
         Number.............. 499
         Variable 1.......... 0026636665
         Variable 2.......... "XXXX"
         Variable 3.......... " "
         Variable 4.......... " "
    Process -
    From WBS element user fields, charactertics value are assigned to profitability segment through derivation rule
    WBS element values settles to Profitability segmnet.
    WBS element has system staus REL  ACPT RESA SETC
    System is giving dump while saving any changes in the project. can anybody tell what is root cause and solution for this issue?
    Thanks,
    Sudhir

    Request you to refer this note 199959.  Take help of you CO cosultant.
    Edited : Request you to check with your CO consultant as PSG has been deleted, take help fo ABAP as well. ( May be above note may not help you much,  WIth help of ABAP and CO define problem and than seach with your message KE499 in Service market place )  That would be better  approach.
    With Regards
    Nitin P.
    Edited by: Nitin  Patoliya on Mar 10, 2010 5:02 PM

Maybe you are looking for

  • Event geeting triggered but WI doesnt  proceed

    Hi All ,   In my workflow , I have have a step which waits for the event 'TRIP.CHANGED' . And when the event is occured next step will be executed .    I have came accross a strange situation wherein  the even is getting triggered but the next step i

  • Help to understand this errors  on my iMac please

    Lafaiete_Neiva Mar 15, 2014 11:33 AM Hello , I need to ask help about this logs Im bean get all the times on the console , you can see some on this post , and I really want your opinion about this logs , its is a error , crash on a more serious probl

  • Error: No SWF Data

    I am attempting to port an application designed for the web onto the Brew SDK 3.1 I have successfully managed to run various Hello World apps. which I have put together but when I publish the more complex application and try to start it in the simula

  • Adding transitions in Premier Pro CS4

    When I edit a movie clip and add it to my project, all seems well. If I then add a transition effect such as a roll out or page turn between clips, extra frames are added that I had intended to cut out. I have one clip that is just right for the proj

  • Error during execution in background: No Test Package Selected

    We have created a test package and tried to run both in foreground (Goto -> Automatic Test -> Execute) and background (Goto -> Automatic Test -> Execute in background). We are pretty confident that the test case included in the package works well. Fo