Why choose Cisco Catalyst WS-C2960-24TC-L Switch ?

As the new family of fixed-configuration standalone devices, Cisco 2960s series intelligent Ethernet Switches provide desktop 10/100 Fast Ethernet and 10/100/1000 Gigabit Ethernet connectivity for entry-level enterprise, mid-market, and branch office networks
to enable enhanced LAN services.
Why choose cisco WS-C2960-24TC-L ?
The Cisco Catalyst WS-C2960-24TC-L has hardware enhancements for network managers, including configurations featuring dual-purpose (alternatively wired) uplinks for Gigabit Ethernet, allowing the network manager to use their Cisco switches as either a copper
or a fiber uplink.

Agreed! WS-C2960-24TC-L has hardware enhancements for network managers, and if you want to buy it, here 3anetwork.com  64%
off, USD 460 ! 

Similar Messages

  • Cisco WS-C2960-24TC-S switch connectivity problam

    I configured my cisco WS-C3750X-12S-S with ip routing and it is working properly. i configured  a cisco  WS-C2960-24TC-S  switch and connect both switches via Fiber. each switches can communicate with other end. i can connect to C3750X from my local WAN, all interfaces are working properly but i cant connect to L2 switch from WAN. please help me.
    (test result pages attached)

    Dear
    the fast Ethernet interface on the switch is meant only for OOB (out of band management) so this way you will not be able to route traffic. It will not communicate to any other subnets apart from the connected subnet. Its better you create a SVI in the switch and use that SVI for management purposes.
    regards
    Najeeb

  • 802.1x on Cisco Catalyst 2960

    I am trying to enable 802.1x on one of
    the switchports of the Cisco Catalyst
    2960:
    C2960#sh run | i radius
    aaa authentication login test group radius local
    aaa authentication dot1x default group radius
    radius-server host 10.250.97.26 auth-port 1812 acct-port 1813
    radius-server source-ports 1645-1646
    radius-server key 123456
    C2960#sh run | i dot
    aaa authentication dot1x default group radius
    dot1x system-auth-control
    dot1x guest-vlan supplicant
    dot1x critical eapol
    C2960#conf t
    Enter configuration commands, one per line. End with CNTL/Z.
    C2960(config)#int g0/14
    C2960(config-if)#dot1x ?
    % Unrecognized command
    C2960(config-if)#dot1x
    As you can see, I can not enable 802.1x
    at the interface level. The code is am running is 12.2.25SEE4:
    Switch Ports Model SW Version SW Image
    * 1 24 WS-C2960G-24TC-L 12.2(25)SEE4 C2960-LANBASEK9-M
    System image file is "flash:c2960-lanbasek9-mz.122-25.SEE4.bin"
    According to Cisco, this image supports
    802.1x. Why can't enable it at the
    interface level?
    Can someone help me out? Thanks.

    some additional info:
    C2960#sh dot1x all
    Sysauthcontrol Enabled
    Dot1x Protocol Version 2
    Critical Recovery Delay 100
    Critical EAPOL Enabled
    C2960#

  • Cisco Catalyst 2955 Causes Some Devices to "Die" During Boot

    I posted this question in the LAN section of the forums, but I realize this is probably the proper forum for my question.
    I have recently purchased a Cisco Catalyst model WS-2955C-12 switch. During POST (boot), the console reports that the switch undergoes what is known as a "FRONT-END LOOPBACK TEST". During this test the 14 port lights on the device light up amber for a moment, connectivity is lost, and after a second or two the lights go off and connectivity returns. We've found that the moment the lights go off at the end of this test, if we have a specific device (with a specific ethernet chip) directly connected to the switch the ethernet chip is adversely affected by this test - the device "goes dark" and is not capable of communicating with anything (including other switches, routers, etc...) until it is power-cycled. What exactly does this FRONT-END LOOPBACK TEST do (I know it's for validating the ports for hardware defects), and what does it send across the wire that could be causing my ethernet chip onboard the device to go bonkers?
    Thanks!
    -Danny

    The ethernet chip on the device (the device is a National Instruments product) is an STMicro STE10/100E, and I'm fairly confident I now know what's happening but I don't know why.
    When my ethernet chip is in Autonegotiate mode, the "FRONT-END LOOPBACK TEST" performed by the catalyst does something where, at the conclusion of the test, the ethernet chip goes into an autonegotiation state and never comes back out of it. I'm thinking the "FRONT-END LOOPBACK TEST" is sending something across the wire that's confusing this specific ethernet chip; I've tried 3 Intel parts and also a Broadcom part and they rode it out in autonegotiation mode just fine. If I put the STE chip into a manually-configured mode the "FRONT-END LOOPBACK TEST" doesn't cause it to "go dark".
    So, my question is really what does the FRONT-END LOOPBACK TEST do? Does it perform a remote loopback test (the STE10/100E doesn't support loopback tests)?
    -Danny

  • IGMP Snooping configuration for Multicasting on Cisco Catalyst 3020

    IGMP Snooping configuration for Multicasting on Cisco Catalyst 3020
    Hi Guru,
    Our switch model is "Cisco Catalyst Blade Switch 3020 for HP"
    We are building HA (High Availability) Databases infrastructure.
    Currently, there are two nodes(hosts- servers) and two above switch for HA.
    Oracle said we need to turn off the IGMP Snooping in order to use the multicasting for their interconnect communication.
    So my question is:
    Q1> Is there any way to use Multicasting without turning off IGMP Snooping on Switch side?
    Q2> If 'yes', how can we configure the switch for Multicasting ?
    Oracle uses 230.0.1.0 & 224.0.0.251 IPs with 42000 range port for Multicasting communication.
    Please shed some light on it

    May I request if you avoid making multiple posts of the same issue?  This will only confuse people (including you). 

  • Cisco Catalyst 2960X Ethernet Switch

    "I want to buy Catalyst 2960-X series switches like WS-C2960X-24PS-L,WS-C2960X-24PD-L, buy I'm not very well know about c2960x series. Can someone help me ?"--from yahoo answer.
    All Catalyst 2960-X Series Switches use a single Universal Cisco IOS Software Image for all SKUs.Cisco Catalyst 2960-X Family of Switches are available with the LAN Base and LAN Lite feature sets.
    WS-C2960X-24PS-L Overview
    Catalyst 2960-X 24 GigE PoE 370W, 4 x 1G SFP, LAN Base Switch
    WS-C2960X-24PD-L Overview
    Catalyst 2960-X 24 GigE PoE 370W, 2 x 10G SFP+, LAN Base Switch

    If you buy the LAN Base model, you'll have all of Cisco's normal switching features and options. My company has purchased many of these switches, and they work very well. Remember, these are access layer switches. If you're looking for something to be an aggregate switch for things that push a lot more data (ex. several wireless controllers), you'll want to go for something more powerful.

  • WS-C2960-24TC-L - %PLATFORM_PM-3-HOSTACCESSFAIL - error

    Hello,
    I have issue with 3 ports on the switch.
    Once I put he following commands under the port I got error message : 
    authentication control-direction in
    authentication host-mode multi-auth
    authentication port-control auto
    authentication periodic
    authentication timer restart 240
    authentication timer reauthenticate server
    authentication timer inactivity server
    mab
    *Jun  7 06:45:18: %PLATFORM_PM-3-HOSTACCESSFAIL: Unable to configure hardware to restrict host access on Fa0/17.  Port may not behave as expected.
    *Jun  7 06:45:18: %PM-4-ERR_DISABLE: port-mode-failure error detected on Fa0/17, putting Fa0/17 in err-disable state
    I have the same configuration under other ports and I don't have any issue.
    When I remove these commands , these 3 ports are working fine.
    What's going on ?  Can you help me to find the root cause ? 
    The device is WS-C2960-24TC-L, Version 12.2(58)SE2
    The current configuration of port is here : 
    interface FastEthernet0/17
     switchport access vlan 274
     switchport mode access
     switchport nonegotiate
     switchport voice vlan 1293
     speed 100
     duplex full
     mls qos trust dscp
     spanning-tree portfast
    Thank you,
    Jan

    Hi Kartnik,
    I found some bugs related to these error message and one is describing our issue : 
    CSCui14520
    Symptom:
    Several ports which are 802.1X-enabled port go into err-disable intermittently.
    Jan 21 13:56:09: PLATFORM_PM-3-HOSTACCESSFAIL Unable to configure hardware to restrict host access on Fa0/9. Port may not behave as expected.
    Jan 21 13:56:09: PM-4-ERR_DISABLE port-mode-failure error detected on Fa0/9, putting Fa0/9 in err-disable state
    Workaround:
    "shut" / "no shut" the port
    Last Modified:
    Apr 7,2014
    Status:
    Terminated
    Severity:
    3 Moderate
    Product:
    Cisco Catalyst 2960 Series Switches
    Known Affected Releases: (1)
    12.2(53)SE2
    Known Fixed Releases: (0)
    No release planned to fix this bug

  • Switch WS-C2960+24TC-L not recognized by CNA

    Switch WS-C2960+24TC-L not recognized by Cisco network assistant. Switch is running on IOS 15.0(2)SE5, CNA 5.8(8.9). CNA show switch as wireless klient.
    I tried upgrade but not help.

    Yes 6.1 supports it , 5.8 does not
    http://www.cisco.com/c/en/us/td/docs/net_mgmt/cisco_network_assistant/version6/relnotes/ol32368.html
    With Cisco Network Assistant 6.0, you can manage these devices:
    Catalyst 2960-Plus switches
    – WS-C2960+24PC-L
    – WS-C2960+24LC-L
    – WS-C2960+48TC-L
    – WS-C2960+24TC-L
    – WS-C2960+48PST-S

  • Ask the Expert: Layer 2 Security on Cisco Catalyst Platforms

    With Wilson Bonilla
    Welcome to the Cisco Support Community Ask the Expert conversation.  This  is an opportunity to learn and ask questions about about issues in designing, planning, and implementing Layer 2 security in your LAN network with expert Wilson Bonilla. 
    Wilson will cover topics that network engineers face daily such as Spanning Tree Protocol security, private VLANs, IP source guard, protected ports, dynamic ARP inspection, virtual LAN access-control lists (VLAN ACLs), and Dynamic Host Configuration Protocol (DHCP) snooping over Cisco Catalyst platforms.  With the fast growth of networks, Layer 2 security is even more critical in the LAN to help your network become more reliable, efficient, and secure. Wilson will answer your questions about LAN networks with Cisco Catalyst switches.  
    Wilson Bonilla is a technical networking trainer at the Learning and Development Department for Cisco Technical Assistance Center located in Costa Rica. Before joining the Training Department, he worked for the Cisco TAC as a customer support engineer focused on LAN Switching for more than two years. While working on LAN switching, Wilson also had roles such as technical leader and trainer, adding to his area of expertise in Cisco Catalyst Layer 2 switching. He has CCNP routing and switching certification and is currently studying to achieve his CCNA certification in data center.
    Remember to use the rating system to let Wilson know if you've received an adequate response. 
    Because of the volume expected during this event, Wilson might not be able to answer every question. Remember that you can continue the conversation in the Network Infrastructure community, subcommunity, LAN, Switching and Routing, shortly after the event. This event lasts through November, 2013. Visit this forum often to view responses to your questions and those of other Cisco Support Community members.

    Hello NetNavi.
    Check the post above about MacSec for more information and let me know if you need further clarification, if so I will do my best,
    In regards to best practices there is a Cisco document; it describes deployments and best practices in every scenario; Supplicants, authenticator, authentication services and other configurations. Please check it out:
    http://www.cisco.com/en/US/prod/collateral/iosswrel/ps6537/ps6586/ps6638/deploy_guide_c17-663760.html
    In regards to Private VLANS:
    What is a Private Vlan?
    A private Vlan is a way to isolate hosts within the same Vlan or broadcast domain. So even when you might have devices sharing the same broadcast domain they can be isolated, this isolated is configured based on sub-domains also most often called primary and secondary Vlans.
    What is a primary Vlan?
    The primary Vlan is representation of the private Vlan, a primary Vlan has one or more secondary Vlans, a switch uses the primary Vlan to present traffic from the secondary Vlans to its neighboring devices.
    What is a secondary Vlan?
    A secondary Vlan is a sub-domain of the primary Vlan. We could say that the secondary Vlans belongs to the primary. The must be associated to a primary Vlan. There are two types of secondary vlans: Isolated and Community secondary Vlans.
    What does it happen to host within a secondary isolated Vlan?
    Host within the isolated vlan; can’t communicate to neither other host in the same isoalted vlan nor host in a community vlan.
    What does it happen to host within the secondary community Vlan?
    Host within the community Vlan can communicate with other host assigned to the same community vlan, but they can’t talk to host in other community vlans.
    What are the benefits of implementing private Vlans?
    Scalability: The most common scenario is a service provider. Imagine all customers of a service provider connected through DSL, cable modem… it’s very likely that all customers belong to the same broadcast domain, however if that’s the case why is it that I can’t use my neighbor’s printer, or maybe why is it that I can’t access the files he has store in his computer, (security) we are in the same broadcast shouldn’t I be able to at least ping his ip address?. Well that’s because the ISP must guarantee some type of security for their customers, and because put every single customer that they have in a single Vlan is not scalable they use private Vlans.
    Examples:
    ISP use private vlans to protect from security bridges, Private vlans and isolated Vlans are used to protect personal information for example from one customer to another.
    DMZ; Many implementations utilizes private vlans in a DMZ to limt or minimize that risk of a compromised server.
    I would like to share this documentation with you for further information and configuration guidelines
    http://www.cisco.com/en/US/tech/tk389/tk814/technologies_configuration_example09186a008017acad.shtml#hw
    This document explains what Cisco Catalyst switches support Private Vlans. 
    http://www.cisco.com/en/US/products/hw/switches/ps708/products_tech_note09186a0080094830.shtml
    Let me know if you have further questions.
    Regards
    Wilson B.

  • Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOA

    Can anyone help figure out why the Catalyst 6509 is not able to assign an IPv6 address? Thank you.
    Cisco Catalyst 6500 version 12.2(33)SXI13 configured as DHCP server for a VLAN responds to Windows 7 client with status code NOADDRS-AVAIL(2). My configuration on the 6500 for the DHCPv6 server is:
    ipv6 dhcp database disk0://DHCPV6-DB
    ipv6 dhcp pool VLAN206IPV6
     prefix-delegation pool VLAN206IPV6-POOL
     dns-server 2620:B700:0:1001::53
     domain-name global.bio.com
    ipv6 local pool VLAN206IPV6-POOL 2620:B700:0:12C7::/65 65
    interface Vlan206
     description *** IPv6 Subnet ***  
     ip address 10.2.104.2 255.255.255.0
     ipv6 address 2620:B700:0:12C7::2/64
     ipv6 nd prefix 2620:B700:0:12C7::/64 14400 14400 no-autoconfig
     ipv6 nd managed-config-flag
     ipv6 dhcp server VLAN206IPV6
     standby version 2
     standby 0 ip 10.2.104.1
     standby 0 preempt
     standby 6 ipv6 2620:B700:0:12C7::1/64
     standby 6 preempt
    I'm getting a result from my debug as follows:
    Apr 10 16:28:02.873 PDT: %LINK-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.873 PDT: %LINK-SP-3-UPDOWN: Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:02.877 PDT: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/2, changed state to up
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Received SOLICIT from FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   dst FF02::1:2
    Apr 10 16:28:03.861 PDT:   type SOLICIT(1), xid 8277025
    Apr 10 16:28:03.861 PDT:   option ELAPSED-TIME(8), len 2
    Apr 10 16:28:03.861 PDT:     elapsed-time 101
    Apr 10 16:28:03.861 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.861 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.861 PDT:   option IA-NA(3), len 12
    Apr 10 16:28:03.861 PDT:     IAID 0x0FF01FAF, T1 0, T2 0
    Apr 10 16:28:03.861 PDT:   option UNKNOWN(39), len 32
    Apr 10 16:28:03.861 PDT:   option VENDOR-CLASS(16), len 14
    Apr 10 16:28:03.861 PDT:   option ORO(6), len 8
    Apr 10 16:28:03.861 PDT:     DOMAIN-LIST,DNS-SERVERS,VENDOR-OPTS,UNKNOWN
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Option IA-NA(3) is not supported yet
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: Sending ADVERTISE to FE80::5D5E:7EBD:CDBF:2519 on Vlan206
    Apr 10 16:28:03.861 PDT: IPv6 DHCP: detailed packet contents
    Apr 10 16:28:03.861 PDT:   src FE80::21D:E6FF:FEE4:4400
    Apr 10 16:28:03.861 PDT:   dst FE80::5D5E:7EBD:CDBF:2519 (Vlan206)
    Apr 10 16:28:03.861 PDT:   type ADVERTISE(2), xid 8277025
    Apr 10 16:28:03.861 PDT:   option SERVERID(2), len 10
    Apr 10 16:28:03.865 PDT:     00030001001DE6E44400
    Apr 10 16:28:03.865 PDT:   option CLIENTID(1), len 14
    Apr 10 16:28:03.865 PDT:     00010001195FD895F01FAF10689E
    Apr 10 16:28:03.865 PDT:   option STATUS-CODE(13), len 15
    Apr 10 16:28:03.865 PDT:     status code NOADDRS-AVAIL(2)
    Apr 10 16:28:03.865 PDT:     status message: NOADDRS-AVAIL

    Hello,
    maybe hitting the following bug.
    Pv6 Address Assignment Support for IPv6 DHCP Server
    CSCse81385
    Hope this helps

  • Can not config full duplex on Gi0/1 of WS-C2960-24TC-L

    Hi,
    I have a problem when connect two modules GLC-FX-100FE to two switch WS-C2960-24TC-L as below:
    When I plug each SFP module like above to each switch WS-C2960-24TC-L to SFP slot (gigabit 0/1: dual purpose port), then the duplex become to Haft.
    So, I can not configure them to full duplex as other copper ports.
    But when I use two switch WS-C3560G-24TS-S, I can do this.
    OS version of WS-C2960-24TC-L I am using is: c2960-lanbasek9-mz.122-55.SE7.bin, I think it is new.
    Please help me solve this problem.
    I have to explain to our customer in the next morning. You know, I am Vietnamese and in Vietnam, the time is 22:40 pm,
    Thank you so much.

    Hi,
    in interface configuration mode you have to configure
    media-type sfp
    Afterwards you can configure media-specific parameters like the duplex mode.
    Note: Changing the media-type will cause an outage for a couple of seconds.
    Hope that helps
    Rolf
    http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_55_se/command/reference/cli1.html#wp13646909

  • Cisco catalyst 2690 switch vlanTable

    Hi,
    I have a cisco catalyst 2690 switch.
    I want monitoring IP, MAC, and Port Address.
    I use this docu: http://docstore.mik.ua/orelly/perl/sysadmin/ch10_03.htm
    This works great:
    htvtef7-nagios:/ # snmptranslate -On BRIDGE-MIB:dot1dTpFdbTable
    .1.3.6.1.2.1.17.4.3
    snmpwalk -c tef7snmp@761 -v 2c 10.76.1.7 .1.3.6.1.2.1.17.4.3
    htvtef7-nagios:/ # snmptranslate -On BRIDGE-MIB:dot1dBasePortTable
    .1.3.6.1.2.1.17.1.4
    snmpwalk -c tef7snmp@761 -v 2c 10.76.1.7 .1.3.6.1.2.1.17.1.4
    htvtef7-nagios:/ # snmptranslate -On CISCO-STACK-MIB:vlanTable
    .1.3.6.1.4.1.9.5.1.9.2
    But I get a error:
    htvtef7-nagios:/ # snmpwalk -c tef7snmp -v 2c 10.76.1.7 .1.3.6.1.4.1.9.5.1.9.2
    SNMPv2-SMI::enterprises.9.5.1.9.2 = No Such Object available on this agent at this OID
    Switch config:
    snmp-server community testament RO
    snmp-server community tef7snmp RO
    snmp-server location XYZ
    snmp-server contact MR.XYZ
    snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
    snmp-server enable traps tty
    snmp-server enable traps cluster
    snmp-server enable traps entity
    snmp-server enable traps cpu threshold
    snmp-server enable traps vtp
    snmp-server enable traps vlancreate
    snmp-server enable traps vlandelete
    snmp-server enable traps flash insertion removal
    snmp-server enable traps port-security
    snmp-server enable traps envmon
    snmp-server enable traps mac-notification
    snmp-server enable traps copy-config
    snmp-server enable traps config
    snmp-server enable traps bridge newroot topologychange
    snmp-server enable traps stpx inconsistency root-inconsistency loop-inconsistency
    snmp-server enable traps syslog
    snmp-server enable traps vlan-membership
    snmp-server host XXX.XXX.XXX.XXX public
    snmp-server host YYY.YYY.YYY.YYY  tef7snmp
    What did I do wrong?
    THX!

    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Normál táblázat";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:10.0pt;
    font-family:"Times New Roman";
    mso-ansi-language:#0400;
    mso-fareast-language:#0400;
    mso-bidi-language:#0400;}
    Thx for the replay!
    I use on the switch c2960-lanbasek9-mz.122-25.SEE3.bin (IOS),
    the Cisco Feature Navigator say, this IOS support the CISCO-STACK-MIB:
    http://tools.cisco.com/ITDIT/MIBS/MainServlet?ReleaseSel=0&PlatformSel=0&fsSel=0&IMAGE_NAME=c2960-lanbasek9-mz.122-25.SEE3.bin&SUBMIT2=Submit&IMAGE_ID=816103
    In show snmp mib I could not find the vlanTable. See the attachment.
    I du not understand!

  • WS-C2960-24TC-L vs WS-C2960-48TC-L

    I want to buy cisco c2960 series switch which support voice, video, data, and highly secure access. My friend suggest me try to use
    WS-C2960-24TC-L or WS-C2960-48TC-L which are equipped with Ethernet 10/100 ports and 2 dual-purpose uplinks. But i don't know what's the difference between them ?

    24TC means it's a 24 port, non-PoE.
    48TC means it's a 48-port, non-PoE.

  • Can i upgrade this switch WS-C2960-24TC-L with lastest IOS 15.0(2)SE6.

    Can i upgrade this switch WS-C2960-24TC-L with lastest IOS 15.0(2)SE6. 

    Yes I see that this is supported on this switch. Upgrade to this switch should not face any problem.
    Suggested
    12.2.55-SE9(MD) 
    Latest
    15.0.2-SE6(MD)
    12.2.58-SE2(ED)
    http://software.cisco.com/download/release.html?mdfid=279963375&flowid=2547&softwareid=280805680&release=12.2.55-SE9&relind=AVAILABLE&rellifecycle=MD&reltype=latest
    HTH
    Regards
    Inayath

  • Connection of LC/APC fiber patch cords to Cisco Catalyst 6500 $ Cisco Access 3750 Switches

    I have an LC/APC fiber patch cord infrastructure and I want to connect it to Cisco Catalyst 6500 & Cisco Access 3750 Switches. what type of transceiver should be used?
    I read a note on Cisco website stating the following for Cisco SFP+ transceivers:
    Note: "Only connections with patch cords with PC or UPC connectors are supported. Patch cords with APC connectors are not supported. All cables and cable assemblies used must be compliant with the standards specified in the standards section"

    Thank you,  but my question is that I have a single mode fiber patch cord with LC/APC connector while cisco stating a note that only use LC/PC or LC/UPC type of connectors with SFP+ transceiver.  
    So what type of transceiver should I use to connect LC/APC patch cord to cisco switches?  Is there another type or SFP+ still can be used? 

Maybe you are looking for

  • Problem with boot / new install system ond SSD

    Hi guys, I have fresh installed system on my new SSD. I use my old HDD as external usb drive. I have problem with boot when I dont have connected HDD to usb. My system boot only to console no to KDE. When I connect external HDD to usb and reboot syst

  • Problem with Updation of entires in table T030

    Hi,    We have written a program to update some entires in the standard table T030.We tried writing INSERT as well as modify statemnt for updating these entirs in internal table.All these entires are new and they donot exist in the table. However the

  • Where can i find the UNIX Solaris Admin guide ?

    I've downloaded the distrib on edelivery (Solaris 10) but most of the admin guide to install Primavera is refering to windows commands ! I've not really time to guess which is the replacement script in unix or whatever so .... Where can i find the So

  • Windows Won't Read my ATI Radeon HD 2400

    Hello, First, I'd like to point off that I'm a moron. So, please speak to me like I am one. So, I'm on my 3rd or 4th Boot Camp installation on this iMac. Meaning, I've had Boot Camp installations for a period of time, and for some reason or another d

  • Rights to sell designs created by KPT Collections

    To Whom It May Concern. Do I have the right to sell designs created by Corel KPT Collections? Thank you in advanced. Regards, hypergraphical