Windows Embedded Standard 7 TCP/IP Services not completely started before user application loads

WES7 is set to autologon a user and launch a startup batch that launches my application.  My application, through a series of LEDs, notifies the user when the system
is initialized and ready to go.  What I've noticed is that even though the system is "up and running" TCP/IP services are not initialized yet.  For example, RDP Server won't respond as well as ICMP/ping and FTP services.  Sometime
later, maybe 20-30 seconds Windows TCP/IP services come alive and everything is okay.  Once other thing to note is that I am using BIT Locker and when I turn it off, TCP/IP services, a majority of the time, are alive immediately at or around autologon.
 My guess is that there is some contention when Windows is logging and starting services and the behavior for which services are started when is not always deterministic.  Is there a way to guarantee TCP/IP services starting before other services?
 I’ve messed around with several services in service manager but none seemed to fix the problem.  One other item to note.  I was able to issue a ping as my first command in my startup script to a fixed IP which appears to force TCP/IP services
to initialize.  The problem with this “hack” is that I don't know any host IP addresses until my system has fully started.  Plugging in the loopback address in the script or my own external IP did not work.
Thanks,
Joe

I forgot this is getting trickier to track this for WES7. There was this method in C#:
http://stackoverflow.com/questions/10855290/which-windows-service-ensures-network-connectivity
Workstation Service or DHCP Service might be good enough. Firewall should be late enough that the network
Of course there are other methods like doing a ping until a an address returns:
http://serverfault.com/questions/612237/how-to-wait-for-network-in-a-batch-script-when-booting-on-windows-server
Other implementations:
https://social.technet.microsoft.com/Forums/windows/en-US/393e6042-dea0-4285-9aeb-2ddf50434f6b/windows-7-always-wait-for-the-network-at-computer-startup-and-logon-group-policy?forum=w7itpronetworking
http://superuser.com/questions/262799/how-to-launch-a-command-on-network-connection-disconnection/262880#262880
I have never tried this one since it is more for domains:
Go to Start -> type in "gpedit.msc" in the run/search field.
In the Local Group Policy Editor that pops up, go to "Computer Configuration" -> "Administrative Templates" -> "System" -> "Logon" -> "Always wait for the network at computer startup and logon"
www.annabooks.com / www.seanliming.com / Book Author - Pro Guide to WE8S, Pro Guide to WES 7, Pro Guide to POS for .NET

Similar Messages

  • Scanjet G2410 not working in Windows Embedded Standard 7 x32

    Not installed the driver for the scanner "scanjet g2410" in "" Windows Embedded Standard 7 x32 "
    Installed as an administrator from the CD and downloaded the latest version from the official site, but every time after the installation refused to start "Solution Center", stating that "the installation center solutions has not been completed, re-install ..." and so on. d.), and in Device Manager reported that "The device is configured incorrectly."
    Tell me, what can be done?
    PS: message written by google translator

    Hello _tetsujin_,
    Welcome to the HP Support Forums!
    To get your issue more exposure I would suggest posting it in the commercial forums since this is a commercial product. You can do this at Scanners.
    The support page for your product may be helpful in the meantime: HP Scanjet G2410 Flatbed Scanner
    I hope this helps!
    JERENDS
    I work on behalf of HP
    Please click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos Thumbs Up" to the left of the reply button to say “Thanks” for helping!

  • Building a Windows Embedded Standard 7 Image

    I'm trying to build a custom Windows Embedded Standard 7 image for a project that requires the machines using the image to share a network HP LaserJet 400 M451nw printer.  The image we had been using apparently does not include all of the packages HP requires, because the install DVD will not work and when Windows tries to install the driver, it fails.  So far, the only bits of diagnostic info I know to share are:
    When the HP installer runs, it tries to install a .NET package (3.5SP1, I think) and exits by telling me that I "must use the 'Turn Windows features on or off' in the control panel to install or configure Microsoft .NET framework 3.5 SP1".  When I look at that function, the dialog is COMPLETELY blank on our embedded image.  What packages must I installed to get this to work?
    Without the running HP installer, I got the printer working on a USB port.  Then I configured the printer's IP address for our network and tried to have Windows install it as a network printer.  Windows found the printer almost immediately, but when it tried to install a driver, it just said that the driver install failed.  Again, I don't know what package I need to include in the WES7 image in order to get this to work.
    I'm seriously hoping that either an HP expert or someone who has already solved this will see my plea for help and provide an answer!

    Hello nurbles,
    Welcome to the HP Forums.
    To get your issue more exposure I would suggest posting it in the commercial forums since this is a commercial product. You can do this at Commercial Forums.
    Thank you for your time.
    Click the “Kudos Thumbs Up" at the bottom of this post to say “Thanks” for helping!
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    W a t e r b o y 71
    I work on behalf of HP

  • LabVIEW Runtime engine on Windows Embedded Standard 7 P 32/64 bit?

    Did anyone ever try to install and run LabVIEW Runtime engine (2011 or later) on Windows Embedded Standard 7 P 32/64 bit?
    I am trying to figure out if this will work, for example on a Beckhoff CX5120 embedded PC. I will need to have some simple TCP/IP communication in order to exchange information with another PC, but nothing else, i.e. drivers, etc...
    I hope someone tried to do this already. I just don't have the right hardware right now to check it out.
    Solved!
    Go to Solution.

    As NI sells touch panels with WES7 installed here: http://sine.ni.com/nips/cds/view/p/lang/en/nid/210551 it's pretty safe to assume they've used the RTE on WES7.
    But yes, it's been done.

  • Windows Embedded Standard (WSE) 2009

    I guess Windows XPe (XP Embedded) no longer exist.  Has anyone tried to run a LabVIEW application on Windows Embedded Standard?  Any reason to think that LabVIEW won't work?  I would like to hear from a developer who has tried WSE out with LabVIEW.
    Thanks!
    Matthew Fitzsimons
    Certified LabVIEW Architect
    LabVIEW 6.1 ... 2013, LVOOP, GOOP, TestStand, DAQ, and Vison

    mfitzsimons wrote: 
    It is NI's official policy that they do not support WSE and LabVIEW.  You are on your own if you choose to go down this path.  I am sure there are limits but haven't found them yet.
    It is NI policy not to support anything that they can not control 100%. Since they can not control which OS components you may add or not add in your embedded system. NI have chosen to not support the WSE "officially". The main reason is that it is very hard to give support to such systems on general basis.
    Besides which, my opinion is that Express VIs Carthage must be destroyed deleted
    (Sorry no Labview "brag list" so far)

  • Can MDT supports Windows Embedded Standard 7?

    Hi,
    Can Windows Embedded Standard 7 OS be captured and deployed using MDT? If so, any limitataions are there?
    What is the best method to deploy WES 7 image?
    Thanks in advance!
    Regards,
    Prabu

    Sure, take a look.
    http://channel9.msdn.com/Events/TechEd/NorthAmerica/2010/WEM301
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread. ”

  • Failed to install audio driver for Kinect, Windows Embedded Standard 7

    I am working on a project that uses the Kinect for Windows. However, the OS is Windows Embedded Standard 7 and it runs on Intel Atom N2600 processor (DE2i-150 board). The Kinect works well on Windows 7. When I migrated the code to WES7, the Kinect does not
    work anymore. All Kinect driver were installed successfully, except for Audio. The board can 'see' the Kinect since it showed the little USB icon on the status bar. However, when I ran some test code from Developer Toolkit, they all said "Kinect is not
    ready" status. I checked the power and reinstalled the SDK/drivers several time but had the same message.
    Does anyone have any suggestion how to solve this problem?

    I would first try a base install of Windows 7 on the same hardware. This will eliminate if it is a WES configurations of a missing component or the device hardware itself. Given that you are running a low powered system, this doesn't meet the minimum hardware
    requirements, let alone the recommended:
    Intel® Atom™ Processor N2600
    (1M Cache, 1.6 GHz)
    http://ark.intel.com/products/58916/
    http://www.microsoft.com/en-us/kinectforwindows/purchase/sensor_setup.aspx
    Dual-core 2.66-GHz or faster processor
    Dedicated USB 2.0 bus

  • Windows Embedded Standard File system cache

    Hey I am new in Windows Embedded.
    I am using Windows Embedded Standard XP, and looking for information regarding cache and file system in OS.
    File Systems are designed to reduce the disk hits. File write operations does not write to disk immediately until we use the flush API. Flush API makes the system slower though. Os on the other hand keeps flushing the data in optimized way.
    We need to know 
    1- how frequent windows embedded standard is flushing the data. ?
    2- How much data it keeps in file system cache(Ram) before flushing ?
    3- Can we change things mentioned in above two points by using code?

    Ok Thank you very much .
    How much data it keeps in file system cache(Ram) before flushing ? How much cache memory i have on ram
    How  we know this ?

  • Windows Embadded standard 7 with service pack 1

    Dear all,
           We are facing a issue with the Windows Embedded Standard 7(SP1).When tried to access the sharepoint library through Internet explorer 8 we are not able to access it.Please refer to the Error below.
             "Your client does not support opening this list with Windows Explorer"
    Awaiting  your resolution asap
    Regards,
    Surya

    This forum is for POSReady. The WES 7 forum is here:
    http://social.msdn.microsoft.com/Forums/en-US/home?forum=quebecmisc
    www.annabooks.com / www.seanliming.com / Book Author - Pro Guide to WE8S, Pro Guide to WES 7, Pro Guide to POS for .NET

  • Windows Embedded Standard 7 (POSREADY 7) and WSUS?

    Do any of you have experience with WSUS and POSREADY 7?
    I am struggling getting some patches to install from our WSUS.  Specifically, KB3000988 and / or KB3008627.  
    My question is - in my WSUS server, these updates show as Update for Windows 7.  I don't see one that applies as an Update for Windows Embedded Standard 7.
    My thought would be that Windows Embedded Standard 7 is just a flavor of windows 7 - so my hopes would be this update should apply - but I can't get it to do so.
    Have any of you seen this?
    Thanks
    sb

    Thanks for the reply.
    Yes - KB2918614 broke something that I need to push out and install an MSI remotely using Powershell, and KB3008627 fixes it.  
    This is a newly deployed image - installed during the month of December across 675 clients.  The updates on the image were installed via the internet -  going straight to Microsoft, and yes, 2918614 was one of them.  I am now trying to push,
    ideally, 3008627 out using WSUS and it is not going well.  
    I have a lab unit next to my desk - freshly imaged to match the field.  I went through and uninstalled KB2918614 - and re-pushed it to this system using WSUS.  It installed without an issue.  But it still wouldn't see the others.
    I then put the Lab unit on a subnet that had internet access and tried to hit Microsoft to see if the patch would install.  It did not show in the list of available updates?!?!  Now I am really confused..
    -sb

  • Windows Embedded Standard 7

    Sticky Notes And Snipping Tools is not available in my Windows Embedded Standard 7 Thinclinet
    i am using model : HP T610
    can anyone help me to get sticky Notes And Snipping Tools

    I don't understand the question.
    In order to add those two items you have to integrate that FeaturePack into your Embedded image using DISM. Alternatively, you *might* be able to add them using DISM's /Online option, but I've never tried it.

  • LabView executable on Windows Embedded Standard 7

    I will like to know if LabView executable with IMAQdx Vision code can be  run on Windows Embedded Standard 7. Thanks.

    Greetings,
    Most certainly, you should be able to use LabVIEW Executables on Windows Embedded Standard 7 that contain Vision VIs. The cRIO 9082 is a great example, for it uses WES7 and brings in GigE Camera support.
    Cordially;
    Simon P.
    National Instruments
    Applications Engineer

  • Support of SHA-2 256 in Windows Embedded Standard 7 SP1

    Is there support for SHA-2 256 in Windows Embedded Standard 7 SP1 OS?
    If so, is there any possibility of setting it through registry settings?

    According to this blog:
    http://blogs.technet.com/b/pki/archive/2010/09/30/sha2-and-windows.aspx Windows 7 (also WES7) supports SHA2.
    www.annabooks.com / www.seanliming.com / Book Author - Pro Guide to WE8S, Pro Guide to WES 7, Pro Guide to POS for .NET

  • TPC 2206 - Windows XP Embedded (XPe) OR Windows Embedded Standard 7??

    Hello. I have to buy a TPC 2206.
    Should I buy with Windows XP Embedded (XPe) OR Windows Embedded Standard 7??
    I have LabVIEW 2012 (DSC y/o touch pannel module) but I'll probably update to LabVIEW 2014 in the future. (II have to be able to program the computer with both options).
    Thanks!

    CracKatoA wrote:
    Ok, But I need to know if I will be able to program the TPC 2206 (witn WES7 installed) with the LabVIEW DSC module 2012 version.
    Based on the LabVIEW OS Roadmap, I think you will be just fine.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • How to automatic start Microsoft VDI Clients on Windows Embedded Standard 7

    Greetings,
    I'm deploy Microsoft VDI for my customer, I use HP Thin Clients with Windows Embedded Standard 7.
    when we start the thin clients, we first open the thin client desktop, then open the RDP connetions, and input the ip address to access the virtual desktop.
    I think it's very complex for the end users.
    I want when we start the thin clients, it automatic connect to the VDI server, we just need to input the username and password to access the users' virtual desktops.
    does anybody know how to set it, or if there are some clients tools ?
    Thanks.
    Frank@Hiweb 冯立超@瀚博资讯

    Hi,
    If you work with mstsc.exe (Microsoft Remote Connection client for Windows), you can simply pre-configure a customized connection and save it as a .RDP file. Then, users can open the connection
    via double clicking the .RDP file.
    In addition, you can create a startup script to run the .RDP file.
    Thanks.
    Jeremy Wu
    TechNet Community Support

Maybe you are looking for

  • Performance degradation of Weblogic 5.1 sp 6 bundled with Peoplesoft 8.1.2:

    Recenly we have upgraded from Peoplesoft 7 to Peoplesoft 8.1.2 Peoplesoft 8.1.2 bundled with Peopletools(Web based front end ) for the first time and Weblogic 5.1 sp6. There is performance degradation of the weblogic 5.1 sp 6 (on Windows 2000 ) when

  • Creative mp3 reliabili

    do all these issues on this message board not tell you something? i have had 2 creative zen 4gb mp3 players and both have gone wrong in a couple of weeks, very little actual direct support too. i can definitly say that i wont be getting another one!

  • Paypal overides our business terms and allows in false claims of non-delivery

    We offer customers in the UK and overseas tracked postage or standard postage. It clearly states on our website that standard postage losses are between the postal services and the customer,and our liability is limitedto providing a standard receipt

  • Editing the Query name for all reports in PRD.

    Dear All, I have created 25 reports using Query Designer.We have moved all the reports to BI Production. And Clients are using these reports using the Tool Bex Analyser. Every time they are navigating through open Query -> Info Areas -> Data targets

  • Anyone have WebDB 2.0.5.6.1 Working?

    OK, I sorted out the installer problem (see my post "Found bug in WEBDB 2.0.5.6.1 installer" on Aug 12, 1999). I even figured out the vauge 'update the tnsnames.ora file with the TNS name alias to your database'. (Turns out you need to make entries f