Workflow Manager Configuration Wizard stuck on "create a new service bus farm"

Hi!
I'm looking for help because i recently tried to install WF Manager on my VM with SP 2013 SP1. Unfortunately every time i try to set wf manager im stuck on this screen:
View Log:
It seems like its stuck "generating certificate". I dont know why and how to troubleshoot this problem. I already tried to wait several hours and nothing happened ....

Hi Brendan,
Is there additional information in Event Viewer?
Also, probably the following links will be helpful for you:
Troubleshooting Workflow Manager 1.0 Management and Execution
Problem starting message broker during service broker configuration
Regards Michael (http://sp2013-blog.com)
Please, don't forget to press upvote (if answer is helpful) and mark as answer (if it solves your issue)

Similar Messages

  • Workflow manager configuration wizard failing

    On running the Workflow Manager Configuration Wizard on our new SharePoint 2013 site, it fails at the stage "Add host to Service Bus farm". I am running as domain admin and have attempted this multiple times but it keeps failing on this part.
    Error log gives this: "[Error] [29/05/2013 11:34:25]: System.Management.Automation.CmdletInvocationException: Starting service Service Bus Message Broker failed: Time out has expired and the operation has not been completed. ---> Microsoft.ServiceBus.Commands.Common.Exceptions.OperationFailedException:
    Starting service Service Bus Message Broker failed: Time out has expired and the operation has not been completed."
    Anybody know the solution to this?
    Thanks

    Hi Brendan,
    Is there additional information in Event Viewer?
    Also, probably the following links will be helpful for you:
    Troubleshooting Workflow Manager 1.0 Management and Execution
    Problem starting message broker during service broker configuration
    Regards Michael (http://sp2013-blog.com)
    Please, don't forget to press upvote (if answer is helpful) and mark as answer (if it solves your issue)

  • Workflow Manager Configuration Wizard is not working with USER ID

    Hello everyone,
       I
    have successfully installed Workflow Manager 1.0 (and its prerequisites) on my Server 2008 R2 SP1 machine that is hosting Sharepoint 2013.  I attempt to go into the Workflow Manager Configuration.  That comes up and asks me if I want to Create
    new farm with Default Settings, New Farm with custom settings, or existing farm.  I've tried both Default settings AND Custom settings.
                When
    the configuration wizard comes up, I attempt to fill out the necessary information.  It seems to connect to the SQL server without a problem.  I only run into an issue when setting the USER ID.  The program totally freezes up and force closes. 
                I
    have verified that the USERID is in the correct format and tried multiple different formats.  The problem is that the moment I move the cursor from the USERID field to ANY other field, the program force closes.  I'm not able to hit submit, I'm not
    able to change any other options.  The moment USERID is manipulated or the cursor LEAVES the USERID field, the program force closes.  It won't even allow me to put in a password before it force closes.
                 Customer
    domain is running in Windows Server 2003 Enterprise Edittion SP2.
    Any
    ideas?
    I have installed also cumulative update to avoid crash but still I am getting force to close workflow wizard. I have used users which are already added in administrator groups.
    We are using 3 tier architecture for Sharepoint 2013.
    Also we have made Alias of Domain controller. Eg:-Alias is "labs" for domain "xyz.ab.com".
    And we are using labs\spadmin and labs\spservice for Workflow Manager Configuration 1.0
    Is there any issue with Domain Alias "labs" as Workflow gives error  "Specified RunAs account is invalid" or "Force close the application".
          I
    have copied the errors from event viewer below:
    APPLICATION
    ERROR
    Faulting
    application name: Microsoft.Workflow.Deployment.ConfigWizard.exe, version: 1.0.20922.0, time stamp: 0x505e1b30
    Faulting module name: KERNELBASE.dll, version: 6.1.7601.17965,
    time stamp: 0x506dcae6
    Exception code: 0xe0434352
    Fault offset: 0x000000000000bccd
    Faulting process id: 0x17f8
    Faulting application start time: 0x01cddee198ece72e
    Faulting application path: C:\Program Files\Workflow Manager\1.0\Microsoft.Workflow.Deployment.ConfigWizard.exe
    Faulting module path: C:\Windows\system32\KERNELBASE.dll
    Report Id: 22ab8b69-4ad5-11e2-af8f-005056965915
    .NET
    Runtime Error
    Application: Microsoft.Workflow.Deployment.ConfigWizard.exe
    Framework Version: v4.0.30319
    Description: The process was terminated due to an unhandled exception.
    Exception Info: System.Runtime.InteropServices.COMException
    Stack:
       at System.DirectoryServices.AccountManagement.PrincipalContext.DoLDAPDirectoryInitNoContainer()
       at System.DirectoryServices.AccountManagement.PrincipalContext.DoDomainInit()
       at System.DirectoryServices.AccountManagement.PrincipalContext.Initialize()
       at System.DirectoryServices.AccountManagement.PrincipalContext.get_QueryCtx()
       at System.DirectoryServices.AccountManagement.Principal.FindByIdentityWithTypeHelper(System.DirectoryServices.AccountManagement.PrincipalContext, System.Type, System.Nullable`1<System.DirectoryServices.AccountManagement.IdentityType>, System.String,
    System.DateTime)
       at System.DirectoryServices.AccountManagement.UserPrincipal.FindByIdentity(System.DirectoryServices.AccountManagement.PrincipalContext, System.String)
       at Microsoft.ServiceBus.Commands.Common.SecurityHelper.IsUserValid(System.DirectoryServices.AccountManagement.PrincipalContext, System.String)
       at Microsoft.ServiceBus.Commands.Common.SecurityHelper.IsDomainUserValid(System.String, System.String)
       at Microsoft.ServiceBus.Commands.Common.ValidateUserAttribute.Validate(System.String)
       at Microsoft.Deployment.ConfigWizard.UICommon.AccountDetailsViewModel.ValidateDomainUser()
       at Microsoft.Deployment.ConfigWizard.UICommon.AccountDetailsControl.UserIdTextBox_LostFocus(System.Object, System.Windows.RoutedEventArgs)
       at System.Windows.EventRoute.InvokeHandlersImpl(System.Object, System.Windows.RoutedEventArgs, Boolean)
       at System.Windows.UIElement.RaiseEventImpl(System.Windows.DependencyObject, System.Windows.RoutedEventArgs)
       at System.Windows.Controls.Primitives.TextBoxBase.OnLostFocus(System.Windows.RoutedEventArgs)
       at System.Windows.UIElement.IsFocused_Changed(System.Windows.DependencyObject, System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.OnPropertyChanged(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.FrameworkElement.OnPropertyChanged(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.Controls.TextBox.OnPropertyChanged(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.NotifyPropertyChange(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.UpdateEffectiveValue(System.Windows.EntryIndex, System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EffectiveValueEntry, System.Windows.EffectiveValueEntry ByRef, Boolean, Boolean,
    System.Windows.OperationType)
       at System.Windows.DependencyObject.ClearValueCommon(System.Windows.EntryIndex, System.Windows.DependencyProperty, System.Windows.PropertyMetadata)
       at System.Windows.DependencyObject.ClearValue(System.Windows.DependencyPropertyKey)
       at System.Windows.Input.FocusManager.OnFocusedElementChanged(System.Windows.DependencyObject, System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.OnPropertyChanged(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.FrameworkElement.OnPropertyChanged(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.NotifyPropertyChange(System.Windows.DependencyPropertyChangedEventArgs)
       at System.Windows.DependencyObject.UpdateEffectiveValue(System.Windows.EntryIndex, System.Windows.DependencyProperty, System.Windows.PropertyMetadata, System.Windows.EffectiveValueEntry, System.Windows.EffectiveValueEntry ByRef, Boolean, Boolean,
    System.Windows.OperationType)
       at System.Windows.DependencyObject.SetValueCommon(System.Windows.DependencyProperty, System.Object, System.Windows.PropertyMetadata, Boolean, Boolean, System.Windows.OperationType, Boolean)
       at System.Windows.DependencyObject.SetValue(System.Windows.DependencyProperty, System.Object)
       at System.Windows.FrameworkElement.OnGotKeyboardFocus(System.Object, System.Windows.Input.KeyboardFocusChangedEventArgs)
       at System.Windows.RoutedEventArgs.InvokeHandler(System.Delegate, System.Object)
       at System.Windows.EventRoute.InvokeHandlersImpl(System.Object, System.Windows.RoutedEventArgs, Boolean)
       at System.Windows.UIElement.RaiseEventImpl(System.Windows.DependencyObject, System.Windows.RoutedEventArgs)
       at System.Windows.UIElement.RaiseTrustedEvent(System.Windows.RoutedEventArgs)
       at System.Windows.Input.InputManager.ProcessStagingArea()
       at System.Windows.Input.KeyboardDevice.ChangeFocus(System.Windows.DependencyObject, Int32)
       at System.Windows.Input.KeyboardDevice.Focus(System.Windows.DependencyObject, Boolean, Boolean, Boolean)
       at System.Windows.Input.KeyboardDevice.Focus(System.Windows.IInputElement)
       at System.Windows.UIElement.Focus()
       at System.Windows.Input.KeyboardNavigation.Navigate(System.Windows.DependencyObject, System.Windows.Input.TraversalRequest, System.Windows.Input.ModifierKeys, System.Windows.DependencyObject)
       at System.Windows.Input.KeyboardNavigation.Navigate(System.Windows.DependencyObject, System.Windows.Input.Key, System.Windows.Input.ModifierKeys)
       at System.Windows.Input.KeyboardNavigation.ProcessInput(System.Windows.Input.InputEventArgs)
       at System.Windows.Input.InputManager.RaiseProcessInputEventHandlers(System.Windows.Input.ProcessInputEventHandler, System.Windows.Input.ProcessInputEventArgs)
       at System.Windows.Input.InputManager.ProcessStagingArea()
       at System.Windows.Input.InputManager.ProcessInput(System.Windows.Input.InputEventArgs)
       at System.Windows.Interop.HwndKeyboardInputProvider.ReportInput(IntPtr, System.Windows.Input.InputMode, Int32, System.Windows.Input.RawKeyboardActions, Int32, Boolean, Boolean, Int32)
       at System.Windows.Interop.HwndKeyboardInputProvider.ProcessKeyAction(System.Windows.Interop.MSG ByRef, Boolean ByRef)
       at System.Windows.Interop.HwndSource.CriticalTranslateAccelerator(System.Windows.Interop.MSG ByRef, System.Windows.Input.ModifierKeys)
       at System.Windows.Interop.HwndSource.OnPreprocessMessage(System.Object)
       at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
       at MS.Internal.Threading.ExceptionFilterHelper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
       at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32)
       at System.Windows.Threading.Dispatcher.Invoke(System.Windows.Threading.DispatcherPriority, System.Delegate, System.Object)
       at System.Windows.Interop.HwndSource.OnPreprocessMessageThunk(System.Windows.Interop.MSG ByRef, Boolean ByRef)
       at System.Windows.Interop.ComponentDispatcherThread.RaiseThreadMessage(System.Windows.Interop.MSG ByRef)
       at System.Windows.Threading.Dispatcher.TranslateAndDispatchMessage(System.Windows.Interop.MSG ByRef)
       at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame)
       at System.Windows.Application.RunInternal(System.Windows.Window)
       at System.Windows.Application.Run()
       at Microsoft.Workflow.Deployment.ConfigWizard.App.Main()
    Thanks
    Hansraj Rathva

    Check to ensure that the user you're running the wizard as has access to the Users and Computers folders in Active Directory. I had trouble with the "specified RunAs account is invalid" message, and when I granted the AD rights, I was able to proceed.
    The issue would be that the user executing the wizard isn't able to query AD to look up the specified user. The RunAs account you're specifying is probably fine.

  • Workflow Manager Configuration - Certificate with Thumbprint does not have a private key

    After following the video series on how to install and Configure Workflow Manager into SharePoint 2013 http://technet.microsoft.com/en-us/library/dn201724(v=office.15).aspx,
    I get to the 'Configure Certificates' section in the Workflow Manager Configuration:  I browse to our wildcard certificate and select it.
    When I try to move to the next page of the configuration wizard, I get the following red error under the certificate:
    Certificate with thumbprint LONG STRING does not have a private key.
    I checked the properties of the certificate, and it says: You have a private key that corresponds to this certificate.
    What am I missing??
    Thank you.
    macrel

    Hi,
    According to your post, my understanding is that you got error under the certificate.
    Please make sure you configure the workflow manager correctly.
    More information:
    Install and configure workflow for SharePoint Server 2013
    Installing and Configuring Workflow Manager 1.0
    Best Regards,
    Linda Li
    Linda Li
    TechNet Community Support

  • Creating a new service for James

    Hi everyone!
    I've got a really big problem..:(
    I would like to create a new "service" for James.
    I would like James to check for email stored from 2 months and do some actions. I wrote the code necessary to do this... but I don't know how to fit it in James...:(
    Should a create a new block??
    I read phoenix documentation too...:(
    Pls help me!!!
    Thanks to everyone!

    Hi Dan,
    As you have discovered, no that won't work. The only position that has system behavior associated with it in RC06 is the system-defined Manager position for a Service Team.
    However, it is the Service Manager Site Permission that enables a user to reassign tasks, not the Manager position for a Service Team. What the Manager position gets you is the convenience of seeing the Service Team, and all of its members, in one place in ServiceManager.
    Any user with the Servic

  • Copy a service P.O. to create a new service purchase order

    I want to create a new service purchase order with items category D. However when I give ref. of some another purchase order the vendor and org. data fields become grey. How do I change these fields in new purchase order which I want to create? In case of material P.O. these fields are editable.
    Pl. help.
    Regards.

    Dear,
    Please check at the time of Service order creation the document type of purchase order is for services. If no please first change document type in ME21N select document type for service po then enter reference of document number in field of purchase order and it's line item at item detail level.
    So please compare your process of purchase order creation with below detail.
    Enter ME21N -Select document type for po.
    Then enter purchase order number in field of reference purchase order field. then check your data.
    Regards,
    Mahesh Wagh.

  • Send an automatic email to business partner when i create a new service call

    HI,
    I NEED TO SEND AN EMAIL TO BUSINESS PARTNER AN AUTOMATIC WHEN I CREATE A NEW SERVICE CALL
    I USE SAP BUSINESS ONE 8.82 PL 15
    THANKS..

    Ivan te adjunto mi código del SP me emite el msg de error:
    " Msg 14607, Level 16, State 1, Procedure sysmail_verify_profile_sp, Line 42
    profile name is not valid
    (1 row(s) affected)"
    Me arroja un valor 0.
    Adjunto mi codigo del SP:
    USE ["MiBase de Datos"]
    GO
    /****** Object:  StoredProcedure [dbo].[Emails_send]    Script Date: 04/14/2015 13:35:59 ******/
    SET ANSI_NULLS ON
    GO
    SET QUOTED_IDENTIFIER ON
    GO
    ALTER PROCEDURE [dbo].[Emails_send]
    AS BEGIN
    EXEC msdb.dbo.sp_send_dbmail
    @profile_name ='MyMailAccount', (Asi se llama el perfil en donde esta config mi mail)
    @recipients ='[email protected]',
    @subject ='Orden de Servicio',
    @body ='Llamada de Servicio',
    @query ='SELECT T0.[ItemCode], T0.[ItemName], T0.[FrgnName]FROM OITM T0 WHERE T0.[ItemCode]= ZF122SM02IDQ',
    @attach_query_result_as_file = 1, @query_result_separator =';',
    @query_result_no_padding = 1, @exclude_query_output = 1,
    @query_result_header = 1,@query_attachment_filename ='LlamadaServicio.pdf'
    END

  • Currupted Workflow Manager Configuration, RE-Installation Guidence?

    Dear All,
    We have few workflows which are currently running in our SP 2013 server farm. The workflows stopped working for sometime, when we examined the errors, we could see that we are no longer able to open the workflow manager and Service Bus configuration wizards,
    they say a certificate is missing in the certificate Store.
    But on visiting the certificate store, I can see that there is a certificate with the Thumbprint specified in the error but it is expired.
    We are not able to find any guidance on how to solve these errors. The Workflow Manager documentation doesn't have this info as on date.
    We can't make our workflows run in the usual way.
    We can't find any guidance on how to re-install the Workflow Manager on such server Farm with workflows deployed and with their history.
    Could you please let us know any possible solution.
    Best regards,
    Prem
    -Prem

    In Test env try to remove all servers from the farm without deleting dbs or uninstalling, then rejoin them, and recreate the certs.

  • Workflow Manager Configuration Issue Windows Server 2012 R2 / SQL 2014

    Hello All,
    Environment:  SharePoint 2013 Enterprise with SP1
    Farm consists of
     2 App Server, 2 Web Server and 2 SQL Servers all the server have Windows 2012 R2 
    OS .  The SQL backend is SQL Server 2014
    Installed Workflow manager on the Web server, the configuration ran fine without any errors. Trying to browse the workflow management site via IIS Manager encountered Certificate Error clicked Continue to this website which gives a HTTP 403 Forbidden and
    following detail message
    This error (HTTP 403 Forbidden) means that Internet Explorer was able to connect to the website, but it does not have permission to view the webpage.
    Checked the web site Workflow Management Site in the IIS manager which has only one folder bin . I was not able to submit the Screenshot
    I have installed the latest patch for the Workflow manager and the Service Bus
    Question I have
    Should there be more folder under the Workflow Management Site.
    Why is the Web site not showing the web page
    Is workflow manager supported for Windows Server 2012 R2 and SQL 2014
    Thanks
    Dhanraj

    Hi Dhanraj,
    I captured the screenshot from my IIS Manager on workflow server. There is only bin folder under Workflow Management site
    If I browser workflow host uri from IIS Manager
    https://localhost:12290, I received certification error, and I chose the continue to this website, it returned me as follow:
    From the link: http://support.microsoft.com/kb/2902007/en-us It is supported on Windows Server 2012 r2 if you have install latest update.
    Here is an article which talks about error:
    http://www.sp2013blog.com/Lists/Posts/Post.aspx?ID=36
    In addition, here is the reference for troubleshooting workflow manager 1.0 management:
    http://msdn.microsoft.com/en-us/library/jj193529(v=azure.10).aspx#AnalyzingWorkflowManagementLogs
    You could also open SharePoint Designer 2013 and see if you could create a workflow on platform 2013.
    Regards,
    Rebecca Tu
    TechNet Community Support

  • Installing SharePoint 2013 Workflow Manager offline - Wizard does not show up

    
    Hello guys,I recently tried to install the workflowmanager to the Application Server of my SharePoint 2013 Farm.I used the following commandline as suggested by spence harbar (in his article).SERVER -D:\SP\WorkflowManager\bin>WebpiCmd.exe /Install /Products:WorkflowManager /XML:D:\SP\WorkflowManager\feeds\latest\w
    ebproductlist.xml
    The wizard does not show up, instead of that, I got an message in my Commandbox:
    The software that you obtain using the Web Platform Installer Command Line Tool is licensed to you by its owner. Microsoft g
    rants you no rights for third party software.
    Successfully loaded primary feed: file:///D:/SP/WorkflowManager/feeds/latest/webproductlist.xml
    The following products are not available on this machine or already installed: WorkflowManager
    No products to be installed (either not available or already installed)
    Can anybody tell me what to do in this situation. I can´t uninstall the software because there is none.
    I need help with this! There is no information in the community about this problem :/
    Greetings Andre

    Hi,
    First of all that blog is old and now you should install Workflow Manager Refresh 1.0. To start fresh, uninstall all components of WF Manager from the server and then follow below mentioned steps.
    Download Microsoft Web Platform Installer 5.0 on a machine where Internet is there.
    Once Installed, go this path in command prompt C:\Program Files\Microsoft\Web Platform Installer and then use this command WebpiCmd.exe /offline /Products:WorkflowManagerRefresh /Path:C:\temp
    Copy the temp folder to the WF Manager machine where you wish to install the WF Manager
    In destination server, use command prompt with elevated privileges and navigate to the temp/bin directory (in copied folder).
    Use this command WebpiCmd.exe /Install /Products:ServiceBus_1_1 /XML:C:\temp\feeds\latest\webproductlist.xml
    Then run this command WebpiCmd.exe /Install /Products:WorkflowClient /XML:C:\temp\feeds\latest\webproductlist.xml
    Then run this command WebpiCmd.exe /Install /Products:WorkflowManagerRefresh /XML:C:\temp\feeds\latest\webproductlist.xml
    -Prashant

  • Creating Managed Server for Weblogic that comes with Oracle Service Bus

    I've installed Oracle Service Bus 10.3.
    Weblogic Server 10.3 comes bundled with OSB 10.3.
    Everything is working fine in the Admin Server.
    But when I create a Managed server and try to start it, I get the following exception and server doesn't start :
    ####<Nov 10, 2009 10:24:32 AM IST> <Critical> <Security> <iflmud6dlb5jn> <OSBManagedServer2> <[ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <> <1257828872747> <BEA-090403> <Authentication for user weblogic denied>
    ####<Nov 10, 2009 10:24:32 AM IST> <Critical> <WebLogicServer> <iflmud6dlb5jn> <OSBManagedServer2> <main> <<WLS Kernel>> <> <> <1257828872747> <BEA-000386> <Server subsystem failed. Reason: weblogic.security.SecurityInitializationException: Authentication for user weblogic denied
    weblogic.security.SecurityInitializationException: Authentication for user weblogic denied
         at weblogic.security.service.CommonSecurityServiceManagerDelegateImpl.doBootAuthorization(Unknown Source)
         at weblogic.security.service.CommonSecurityServiceManagerDelegateImpl.initialize(Unknown Source)
         at weblogic.security.service.SecurityServiceManager.initialize(Unknown Source)
         at weblogic.security.SecurityService.start(SecurityService.java:141)
         at weblogic.t3.srvr.SubsystemRequest.run(SubsystemRequest.java:64)
         at weblogic.work.ExecuteThread.execute(ExecuteThread.java:201)
         at weblogic.work.ExecuteThread.run(ExecuteThread.java:173)
    I've tried changing the boot.properties file and given clear text username and password, but even this did not change the exception.
    Are there any other security concerns that are to be taken care of while configuring Managed Server for Oracle Service Bus?
    Kindly help.

    How are you starting the manageserver. Is it using command line or using NodeManager from Weblogic console of admin server. Most of the times we start managed server using yourDomain/bin/startManagedWebLogic.cmd (.sh).
    startManagedWebLogic nameOfYourManagedServer adminURL(Ex: http://host:port).
    If you created a managed server at the time of creation of domain itself using custom option, then under your domain root folder, you should see a file named like "startManagedWebLogic_readme.txt" that kind of gives the same above command.
    If you added the managed server later on, to an existing single server domain, then you can use the above command.
    Ravi Jegga

  • Help: BPC admin view stuck in creating a new App set

    Hello,
    We have SAP BPC 7.5.05.1002 NW. I have tried to create a new app set by copying an existing application set. The BPC admin view has been stuck for a couple of hours now. I have a dialog box on the screen, with the message "Waiting for the server's response....". The "OK" button is greyed out.
    I would appreciate any help on this. What would happen if I were to cancel this (shut-down my BPC front end)? Would that cause any problems in the BPC application or the application set which is copied across to the new app set?
    Thanks in advance.

    Hello,
    Thanks for your response. I don't have access to the back-end BI/BW and the IT support will take a long time to get back to me.
    How do I cancel this task?

  • Service Manager 9.21: How to create a new instance of scautolistener and assign a port to it.

    Hi,
    2 instances of scautolistener are already running and i want to create a new instance of scautolistener.
    The sm.cfg file entry of scautolistener instances are:
    sm -scautolistener:12670 -debugscauto -log:..\logs\scauto.log
    sm -scautolistener:12690 -log:..\logs\scsmtp.log
    Please guide me as how to create a new instance of scautolistener.

    first, you cannot create instances of methods. but you can create instances of classes (==objects).
    the algorithm for primes does not work yet (its your work) but i inserted the code to create your object.
    import java.math.*;
    public class IsPrime {
    public boolean isPrime1(int arg){
    for(int e = 2; e < arg; e++){
    int remainder=arg%e;
    if(remainder==0){
    System.out.println("This number is not a prime number");
    break;
    else {
    System.out.println("This number is a prime number");
    break;
    return true;
    public static void main(String[] args){
    System.out.println(args.length);
    if (args.length>1){
    System.out.println("Sorry you can only enter one number");
    else{
    String sNum =args[0];
    int iNum=Integer.parseInt(sNum);
    IsPrime myPrimesObject = new IsPrime(); // here is your object
    if (myPrimesObject.IsPrime1(iNum)==true)
    System.out.println("is a prime");else System.out.println("is not a prime");
    }

  • Service created with New-Service does not start

    Hello,
    I am trying to create a working service using the New-Service cmdlet. I tried a bunch of different examples, I found on the internet like this one from technet:
    new-service -name TestService -binaryPathName "C:\WINDOWS\System32\svchost.exe -k netsvcs" -dependson NetLogon -displayName "Test Service" -StartupType Manual -Description "This is a test service."
    The service gets created and is listed in services.msc and Get-Service but I cannot start it. Ever. The state changes to "Starting" but that's all.
    I tried it on different machines with different Windows- and PowerShell versions using elevated PS-consoles.
    Thanks,
    Manuel

    Hi Manuel,
    I tested on my client, and I also keep getting the error 1053, which indicates timeout and the new created service can not be started during the limit time, so you can try to change the service time limit, please note this needs to change registry value,
    Using Registry Editor incorrectly can cause serious problems:
    In Registry Editor, locate, and then right-click the following registry subkey:
    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
    a.Point to New, and then click DWORD Value. In the right pane of Registry Editor, notice that New Value #1 (the name of a new registry entry) is selected for editing.
    b.Type ServicesPipeTimeout to replace New Value #1, and then press ENTER.
    c.Right-click the ServicesPipeTimeout registry entry that you created in step c, and then click Modify. The Edit DWORD Value dialog box appears.
    d.In the Value data text box, type TimeoutPeriod, and then click OK
    Refer to:
    Error 1053: The service did not respond to the
    start or control request in a timely fashion - When trying to start the server service.
    Please Note: Since the web site is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    If there is anything else regarding this issue, please feel free to post back.
    Best Regards,
    Anna Wang

  • TableAdapter Configuration Wizard gives error when adding new TableAdapter

    Hi,
    I recently downloaded and installed the ODT for visual studio on my computer. I am running VS2008 on Windows 7 64-bit. I am able to create an ODP.NET connection to the Oracle XE 10.2g instance that is running on my computer with no problems and use that connection to browse the database. When I add a DataSet to my project, and start adding TableAdapters to the DataSet, I am getting errors. In an attempt to figure out what the problem is, I have followed various scenarios. I will describe each scenario, and what the end result is, and then after I have described them all, I will explain what I think the problem might be. Here are the different scenarios I have used:
    Scenario 1:
    From the Server Explorer, highlight ALL of the tables in my schema and drag them to the designer (all table adapters are added with no issues). I can add additional queries to each of the TableAdapters and then change the additional queries by right clicking and choosing "Configure". This all works with no issues. However, on certain TableAdapters, if I try to modify the primary query (Fill,GetData()), I can open the query editor just fine, change various settings, etc, but when I click on "Finish" I get the following error:
    Configure TableAdapter TABLENAME failed.
    Index was outside the bounds of the array.
    Scenario 2:
    From the Server Explorer, drag tables from my schema onto the designer one at a time. Some tables get added just fine, but for the rest of them, I get the following error:
    Failed to merge object(s).
    Index was outside the bounds of the array.
    Scenario 3:
    On the Dataset Designer, add tables one at a time by right clicking and choosing "Add -> TableAdapter" and then using SQL to define the query for each table. Some tables get added just fine, but for the rest of them, I get the following error:
    Failed to add TableAdapter.
    Index was outside the bounds of the array.
    Ok... now that I have described all of the different scenarios, I will explain what I think the problem is, and why. Based on my research, I believe the underlying problem has to do with Foreign Key Constraints on the various tables. While working on Scenarios 2 & 3, the same exact tables worked just fine in both scenarios. When I started looking at the definitions for the tables in my schema, it turns out that all of the tables that failed had foreign key constraints defined. When I remove the FK constraints from a table, I am then able to add it to my dataset and change the default query with no problems. My original application used the System.Data.OracleClient provided by Microsoft. When adding my tableadapters using the microsoft data provider, the FK relations are automatically generated for me in the designer, but not with the Oracle Data Provider
    I would be happy to provide you with the DDL that I used for creating my schema (it is not very big) if needed.
    Thanks,
    Jim

    Sorry let me clarify some of the config a little more.
    MAIL101 - Exch 2013
    MAIL102 - Exch 2013
    AP104 - Witness (strictly a witness nothing else on this machine)
    EDGE01 - Exch 2007 Edge
    CAS01 - Exch 2007 Hub/CAS load balancer for CAS02/03
    CAS02 - Exch 2007 Hub/CAS
    CAS03 - Exch 2007 Hub/CAS
    MBOX01 - Exch 2007 Mail cluster
    MBOX02 - Exch 2007 Mail cluster node
    MBOX03 - Exch 2007 Mail cluster node
    RDC01, RDC02, RDC03 - all 2008 R2 root domain controllers for rootdomain.rootdomain
    DC01, DC02, DC03, DC04 - all 2008 R2 domain controllers for us.rootdomain.rootdomain
    All DCs are Global Catalogs.
    I can ping all DCs and root DCs fromboth MAIL101 and 102
    The Exchange Replication service is running on both MAIL101 and 102.
    DC03 is in the same site as the MAIL101/102 servers so I'll run all replication tests from here.
    DCDIAG comes back with all tests passed.
    repadmin /replsum comes back with 0 fails and no errors largest delta for any intersite communication is 13min.
    When I run Test-ReplicationHealth -Identity MAIL101 and also 102 they both come back as everything passed.  No errors.

Maybe you are looking for

  • Need Help: Adobe Acrobat Pro 9 Slow Performance on MacPro

    We installed Adobe Acrobat pro as part of Design premium on MACPRO twelve Core 2.93 with 10GB Memory and 27inch Display running OS 10.8.4 We opened high resolution pdf file 170MB with 330pages with 300% Zoom, when we scrolled trough the pages, the re

  • I cant get it to turn off!

    Mu iphone 5 is burning battery like crazy.  I can't get it to stop -- I put it in lock, screen is dark, but it still runs warm and runs down the battery.  Auto lock is set to 5 min, and it locks.  I ran through an entire charge in 3 hours.  What am I

  • Issue in reselecting an item In JCombo.

    Hi Wishing u a very happy new year..! I have 5 items in my JCombobox. It’s a customized combo box. When I select any item in the combo, it will paste command related to the selected item in a TextArea. But problem is when I selects any item (e.g. x i

  • Problem opening downloaded PDF files

    When I click on a PDF link in Safari, I would normally expect the document to open with Acrobat 7.0. What is happening now, is that the screen changes to 'browse' option asking me to identify which application will open the PDF. When I click on Acrob

  • Photoshop CS5  bridge is a memory Hog

    I am running windows 7 with 10GB of RAM. I noticed that my CPU reading will surge at times. The ram meter will show a continuous 23% RAM reading  with bridge running. Is this normal?