Hi All
I have Oracle Applications 11.5.10.2. Once I login to applications its showing me the responsibilites but its not displaying the notification list or worklist as it used to show in version 11.5.9.
How to display this worklist without going through the navigation of Workflow > Worklist ?

The old mod_plsql worklist from 11.5.9 is no longer available. Please give your users Workflow User Web Applications (or any of the Workflow User/Administrator) responsibilities. The worklist is now on the Notifications Link, and the Status Monitor allows investigation of workflows in progress/error.

Similar Messages

  • Battery , time , signal strength bar is not getting displayed in home screen , these will be displayed only when i click on any app. Can u let me know the setting change ?

    Battery , time , signal strength bar is not getting displayed in home screen , these will be displayed only when i click on any app. Can u let me know the setting change ?

    Did you check the Zoom setting?
    Have you tried a reset (reboot)? Hold HOME and SLEEP until an Apple logo appears.
    If it isn't Zoom and a reboot doesn't help try Settings/General/Reset - Reset all settings

  • OLM Courses uploaded thru API not getting displayed on the screen

    Hi All,
    I am new to OLM. I am working on Oracle Apps EBS 11.5.10.2.
    I have uploaded a list of courses using Oracle provided API (OTA_ACTIVITY_VERSION_API.CREATE_ACTIVITY_VERSION) and it got successfully uploaded into the base tables.
    But I am unable to see those uploaded course on the --> Learning Administrator responsibility >Catalog screen.
    Kindly give your inputs so as to resolve the issue.
    Thanks and regards,
    Ahmed.

    Hi user629449 ,
    Can you share the (OTA_ACTIVITY_VERSION_API.CREATE_ACTIVITY_VERSION) API you wrote and lets see the API and what could cause the error.
    This will make it easy to learn and resolve.
    Best Regards

  • Catalog codes not getting displayed in Field- QS41

    During my customisation activity, codes of catalog profiles are not getting displayed in SAP screen. Field for codes are showing as blank grey area in QS41 Tcode. If I try creating same codes again, system throwing error saying "key for entry is exisying already".
    Another observation is in the initial screen of QS41 if I select catalog and codes from folders all codes we can see for selection in initial screen, but same is not getting displayed in field for codes in QS41, its showing blank grey fields. Could anyone tell me what might be reason. Its happening for standard catalog profiles also.
    Could anyone tell me what might be the reason.

    Hello Vineeth,
    could you please apply note [1078292|https://service.sap.com/sap/support/notes/1078292] in your system this should resolve the discribed issue.
    Regards,
    Isabelle

  • Standard screen not getting displayed in a zcopied prg

    Hi Freinds,
    (In sap4.7  ) I had copied QA32 into a ZQA32 and had added some validation checks before user Chooses Defects Button,,this ZQA32 works till that point fine but when the Defects button is chosen,,it gives a call to Tcode QA11 ,with the initial screen fields  filled up,,
    in the normal processing of QA32 when QA11 is called,,it is also filled up with some intial values carried from previous Tcode QA32 and after User presses execute button in QA11 intial screen ,further a screen(200) with 3 radio buttons pops up,,
    my ZAQ32  is failing at this point though the line of code  where the screen is called (call screen 200 ...) is reached with no variations in  values of any of the variables in comparison with when it is called from QA 32,
    the screen 200 is not getting displayed if i reach QA11 thru  ZQA32,,,
    Though it is  ALSO calling QA11  and hence the program control is tranferred to QA11, but still the screen is not geting displayed,plz tell me where  i went wrong??
    Thanks in advance

    Hi Sri lakshmi ,
    You should debug the code starting from call to QA11 and check if will the conditions are met for call of pop up screen.
    This will give you an idea, as what is exactly required for this pop up to appear.
    Hope this helps you.

  • Values are not getting displayed in screen

    Hi Experts,
    I have used BAPI_CHARACT_CREATE to upload characteristics(t-code: ct04),
    All data are uploaded into the Master Table, while changing the same in t-code ct04 the Value and Description is not getting displayed in screen( in Table control).
    NOTE: If i use BAPI_CHARACT_GETDETAIL to get the details of a character i am getting all the values which i have uploaded. (But not in the t-code ct04).
    BDC and LSMW is not working for this t-code.
    Please help me out.
    Thanks and Regards,
    LOGU

    Hi,
    i think you have not released the objects to repository. test and try again..
    thanks
    karthik

  • SAP Fields not getting displayed on the BDT screen

    Hello Gurus,
    I am trying to add 2 custom fields on to the claims management screen. The following steps were followed to add 2 fields on to the claims Management subclaim screen.
    1. Create a field group Zxxxxx1 with the two fields attached to it as input enabled.
    2. Create a View Zxxxxx2 attach the created field group Zxxxxx1, then create a subscreen screen add two fields to the screen and make them as input enabled. Then attached the subscreen to the View.
    3. Create a PBO and PAI function modules for the screen and attach it to the View Zxxxxx2.
    4. Create a section Zxxxxx3 and attach the view Zxxxxx2 to the section.
    5. Attach the section to the Subclaim Overview Screen.
    6. Inspite of doing all the above steps the screen is not getting displayed or the Function module PAI / PBO / FMOD is not being called.
    Since I am attaching the section to a standard screen sequence I am not doing any modification to the screen sequence and screen sequence catagory.
    Kindly let me know the steps I am missing in the configration of 2 new fields via BDT.
    Reagrds,
    Shiva

    Hi Shiva,
    did you create your own Z BDT application? Is it set to be active?
    I have no access to any claims management system: Does the claim object support divisibility? If so, have you assigned the correct data set in your view?
    Also, if you have your own Z BDT application and the claim object does support divisibility, did you assign the Z application to the divisibility view?
    Regards,
    Frank
    Message was edited by: Frank Vieregge

  • Screen fields not getting displayed after Line 16

    Hi All,
    There is a screen exit created in IW51, now the new requirment is to add 3 more fields.  I added the fields below the exiting fields, in line number 15 , 16 &17. After executing the Tcode I could find that the field created in line 17 is not getting displayed in runtime. I have increased the screen length. The fields if moved to line numbers below 16 then they are getting displayed. Can anyone help me to find why it is not getting displayed after line 16.

    Hi,
    Can you give me the Enhancement name?
    I searched for the exits using package , but i did not find any screen exists for that IW51 Tcode?

  • Trying to install VM Server and not getting the CD found screen to display

    Trying to install Oracle VM Server from a CDROM:
    1.     Insert the Oracle VM Server CDROM into your CDROM drive.
    2.     Boot the computer with the Oracle VM Server CDROM.
    3.     The Oracle VM Server screen is displayed.
    All that went fine but not getting the CD found screen to display. Instead it says the device wasn't found and shows a list of drivers, none of which seem to match the CD drive. Anyone have any ideas? There is an option to point it to a driver disk, not sure if I need to get the driver from somewhere and do that or not?
    machine is Dell Optiplex 760
    CD RW\DVD RW drive

    Try changing the SATA mode in the BIOS to AHCI.

  • Portal Forms are not getting displayed in the new oracle environment.

    Hi All,
    The Forms in our Portal applications are not getting displayed after we have done the upgradation of Database in Unix from 8i to 9i. The reports are working fine.The forms that were added as portlets are not getting displayed and other forms that are called thorough links returns error when it is run. The Newly created forms are also not running but returns error. The Portal Version is 3.0.9.8.3. Pls help.
    Regards,
    Tom

    Hi ,
    Based on the requirement , check whether the customer contact has been done carried out for the invoice  , then possibility it must have gone out of the worklist , chekc whether the Invoice posted in the AR has been transferred to FSCM collection .

  • Iam not getting the data on screen after using the user exit zxpadu01

    Dear Freinds
                As per my requirement when the user enters value Ansal  it should get defaulted to Amount field (bet01 ) based on the wage type
    i have written calculation ( q0008-bet01 = ansal/100) before it getting defaulted to bet01, i found that value is not getting default  on the screen for bet01 once i enter value for Ansal , please any body correct my code
    in   ZXPADU02 i have written the code as  below :
    data : wa_p0008 like p0008,
            i0008 like p0008,
           l_v_ANSAL type ANSAL_15,
           l_v_amount type PAD_AMT7S.
    CASE innnn-infty.
    when '0008'.
    CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
    EXPORTING
    prelp = innnn
    IMPORTING
    pnnnn = wa_p0008.   -- HERE I GOT ALL THE DATA EXCEPT BET01
    if wa_p0008-lga01 = 'MFPY'.
    l_v_ansal =  wa_p0008-ansal.
    l_v_amount = l_v_ansal / 100.
    move l_v_amount to wa_p0008-bet01.
    CALL METHOD cl_hr_pnnnn_type_cast=>pnnnn_to_prelp
    EXPORTING
    pnnnn = wa_p0008  --- HERE I CAN SEE EVEN THE BET01 IS FILLED
    IMPORTING
    prelp = innnn.         --- HERE I CAN SEE LGART BUT NOT AMOUNT VALUE
    endif.
    when others.
    endcase.
    IN ZXPADU01 I HAVE WRITTEN AS BELOW:
    data : wa_p0008 like p0008,
            i0008 like p0008,
           l_v_ANSAL type ANSAL_15,
           l_v_amount type PAD_AMT7S.
    CASE innnn-infty.
    when '0008'.
    MOVE-CORRESPONDING  innnn to wa_p0008.
    CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
    EXPORTING
    prelp = innnn
    IMPORTING
    pnnnn = wa_p0008.
    if wa_p0008-lga01 = 'MFPY'.
    l_v_ansal =  wa_p0008-ansal.
    l_v_amount = l_v_ansal / 100.
    move l_v_amount to wa_p0008-bet01.
    CALL METHOD cl_hr_pnnnn_type_cast=>pnnnn_to_prelp
    EXPORTING
    pnnnn = wa_p0008   --- I CAN SEE ONLY WHEN I COME AGAIN
    IMPORTING
    prelp = innnn.
    endif.
    when others.
    endcase.
    Now my problem is as follows :
                   i have entered the value for Ansal (ex: p0008-Ansal = 1000) ..........and i say enter then i should found the calculated value for the ansal through my coding
    and it should  display in bet01 as 10 ( q0008-bet01 =  p0008-ansal /100)
    but i dont find the value 10 being displayed for the field bet01 on the screen  when
    user enters Ansal  as 1000 .........even then i have saved it to test the scenario......
    now i came in displayed mode (pa20 ) for the infotype 008 for the same personnel no for the same  dates .....where i created the record........i found that the value
    bet01 is there i.e i can see  the value bet01 as 10 ( my requiremnt here matching)
    but when the user say enter during the time of creation of the record the value
    bet01 is not getting defaulted with 10 .........why iam not able to understand
    PLEASE ANY BODY HELP ME IN THIS REGARD 
    regards
    shanti.

    Hi Pranesh,
                   i have used the logic which you hav given as below
    in ZXPADU02
      FIELD-SYMBOLS <fs>  TYPE ANY.
    ASSIGN ('(MP000800)Q0008-betrg') TO <fs>.
    if <fs> is assigned.
    <fs> = l_v_amount .  ---  amount as (ansal /100 i.e 1000/100 = 10) 10
    endif.
    still iam not getting the data for the field bet01
    this is the coding i am using
    data : wa_p0008 like p0008,
            i0008 like p0008,
           l_v_ANSAL type ANSAL_15,
           l_v_amount type PAD_AMT7S.
      FIELD-SYMBOLS <fs>  TYPE ANY.
    CASE innnn-infty.
    when '0008'.
    MOVE-CORRESPONDING  innnn to wa_p0008.
    CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
    EXPORTING
    prelp = innnn
    IMPORTING
    pnnnn = wa_p0008.
    if wa_p0008-lga01 = 'MFPY'.
    l_v_ansal =  wa_p0008-ansal.
    l_v_amount = l_v_ansal / 100.
    move l_v_amount to wa_p0008-bet01.
    ASSIGN ('(MP000800)Q0008-betrg') TO <fs>.
    if <fs> is assigned.
    <fs> = l_v_amount .
    endif.
    CALL METHOD cl_hr_pnnnn_type_cast=>pnnnn_to_prelp
    EXPORTING
    pnnnn = wa_p0008
    IMPORTING
    prelp = innnn.
    endif.
    when others.
    endcase.
    please help me as iam still not getting (value in bet 01) when i press enter once i enter value in ansal feild.
    regards
    shanti.

  • Search Help not getting displayed

    Hi ,
    I have included my own Search Help ZSH to Standard Search Help MAT1 which is related to field MATNR , in the following path..
    In MAT1->MAT1_A, I have INCLUDED my Search Help.
    I have tested it in SE11, it's working fine.
    But, in VA01 screen when I press F4 on the MATNR field only 9 Search Helps are displayed, and my Z-Search Help is not getting displayed.
    What additional settings should I do for the display of my Z-Search Help?
    Thanks in advance,
    Shivaa...

    Also look at this thread Search help enhancement - VA01
    Regards,
    Raymond

  • WRITE STATEMENT IS GETTING EXECUTED BUT NOT GETTING DISPLAYED

    HII All,
    i hv created a selection screen with push button. Now when i m clicking that pushbutton, output is not getting displayed..when i debug program ,control enters in switch case and also executes write statement but write statement is not getting displayed.. below is the code ..
    SELECTION-SCREEN BEGIN OF BLOCK INPUT WITH FRAME TITLE TEXT-001.
      SELECTION-SCREEN PUSHBUTTON 10(20) TEXT-002  USER-COMMAND FIR.
      SELECTION-SCREEN PUSHBUTTON 35(20) TEXT-003  USER-COMMAND SECOND.
    SELECTION-SCREEN END OF BLOCK INPUT.
           WA-EMP_NO = 123.      
            WA-EMP_CO = 'A'.
            WA-EMP_N = 'APOORV'.
            APPEND WA TO IT_TAB.
    AT SELECTION-SCREEN.
    CASE SY-UCOMM.
    WHEN 'FIR'.
    PERFORM SUB1.
    WHEN 'SECOND'.
            APPEND LINES OF IT_TAB FROM 2 TO 3 TO IT_TAB1.
            WRITE:/ 'SECOND INTERNAL TABLE CONTENTS'.
            LOOP AT IT_TAB1 INTO WA1.
            WRITE:/15 SY-TABIX, WA1-EMP_NO NO-ZERO, WA1-EMP_CO, WA1-EMP_N.
            ENDLOOP.
    ENDCASE.
    FORM SUB1.
    LOOP AT IT_TAB INTO WA.
              WRITE:/ SY-TABIX, WA-EMP_NO NO-ZERO, WA-EMP_CO, WA-EMP_N.
    ENDLOOP.
    ENDFORM.
    Plz help me..
    Edited by: Julius Bussche on Jan 29, 2009 1:40 PM
    Code tags added and please dont use Caps-Lock.

    HI,
    SELECTION-SCREEN BEGIN OF BLOCK INPUT WITH FRAME TITLE TEXT-001.
    SELECTION-SCREEN PUSHBUTTON 10(20) TEXT-002 USER-COMMAND FIR.
    SELECTION-SCREEN PUSHBUTTON 35(20) TEXT-003 USER-COMMAND SECOND.
    SELECTION-SCREEN END OF BLOCK INPUT.
    WA-EMP_NO = 123.
    WA-EMP_CO = 'A'.
    WA-EMP_N = 'APOORV'.
    APPEND WA TO IT_TAB.
    * AT SELECTION-SCREEN.                 "Comment this
    START-OF_SELECTION.                     " Add this
    CASE SY-UCOMM.
    WHEN 'FIR'.
    PERFORM SUB1.
    WHEN 'SECOND'.
    APPEND LINES OF IT_TAB FROM 2 TO 3 TO IT_TAB1.
    WRITE:/ 'SECOND INTERNAL TABLE CONTENTS'.
    LOOP AT IT_TAB1 INTO WA1.
    WRITE:/15 SY-TABIX, WA1-EMP_NO NO-ZERO, WA1-EMP_CO, WA1-EMP_N.
    ENDLOOP.
    ENDCASE.
    FORM SUB1.
    LOOP AT IT_TAB INTO WA.
    WRITE:/ SY-TABIX, WA-EMP_NO NO-ZERO, WA-EMP_CO, WA-EMP_N.
    ENDLOOP.
    ENDFORM.

  • Problem in BADI, error message not getting displayed

    Hello Experts,
    I am facing a strange problem in BADI.
    The requirement is that the user should not be allowed to change the plant field
    on the screen of standard MM transctions for PO/PR amendment.
    I have written the code in separate BADIs for PO and PR.
    I am displaying an error message if the user tries to change the field.
    For PO, it is working fine.But for PR, the same code is not working.
    The control is going over to the BADI for PR and rest of the code is working fine.
    But the error message is not getting displayed for PR amendment.
    Can anybody please suggest the possible cause of problem and some solution to it.
    Thanks in advance.

    Hi
    See the sample BADI code for PR which raises an exceptions and do accordingly
    BAdI Name: ZPUR_RFQ (Implementation name) Purchase Requisitions
    Definition Name: ME_REQ_POSTED
    Interface Name : IF_EX_ME_REQ_POSTED
    Implementing Class: ZCL_IM_PUR_REQ
    Method :            POSTED
    METHOD if_ex_me_req_posted~posted .
      DATA : v_mtart TYPE mtart.
      DATA l_s_eban TYPE ueban.
      LOOP AT im_eban INTO l_s_eban.
        IF l_s_eban-estkz NE 'B'.
          CLEAR v_mtart.
          SELECT SINGLE  mtart INTO v_mtart FROM mara WHERE matnr = l_s_eban-matnr.
          IF v_mtart EQ 'ZERS' OR v_mtart EQ 'FHMI' OR v_mtart EQ 'UNBW'.
            MESSAGE e000(zm_msg) WITH 'You are not allowed' 'to create PR for stock items'.
          ENDIF.
        ENDIF.
        IF  l_s_eban-knttp NE 'F' OR l_s_eban-pstyp NE '9'.
          IF l_s_eban-knttp NE 'A'.
            IF ( l_s_eban-pstyp NE '9' AND l_s_eban-pstyp NE 'D' ) 
               AND l_s_eban-matnr EQ space.
              MESSAGE e000(zm_msg) WITH 'You cannot create'
                'a PR without material number'.
            ENDIF.
          ENDIF.
        ENDIF.
      ENDLOOP.
    ENDMETHOD.
    <b>Reward points for useful Answers</b>
    Regards
    Anji

  • The html select box option is not getting displayed properly in IE11

    The html select box option is not getting displayed properly in IE11
    I have developed a website that has a select box drop down. The select box drop down is getting displayed properly in IE9. But in IE11, if I am selecting any option apart from the first one, the whole select box option is getting moved up in the page.
    In IE11, if option 2 is selected, then the select options is getting moved up. But in IE9, if option 2 is selected, then the select options is getting displayed properly.
    Please let me know the fix so that the select options are displayed in the same manner as in IE9.
    Sorry but I am unable to upload images as this site is throwing some error

    Hi Kevin Shen,
    Thanks for post.
    I tried above code in ie 11(version 11.0.9600.17633).
    But it is not working. If you select option 2, and open select box then it open on the select box.
    It should open below the select box.
    Code for above:-
    <select>
    <option>1</option>
    <option>2</option>
    <option>3</option>
    </select>
    Sorry I could not attach screen shot. We have normal select box with three options. If we select option 2, it is showing option list on the select box. It is coming below the select box in ie 10 and other browse like chrome. 
    So what we should do, so that all options will come below the select box?
    Thanks,
    Yogesh Toke

Maybe you are looking for

  • Material Determination error during Transaction DP90

    Dear Experts, I am configuring the Depot Repair scenario for a Hitech Industry. The Process is as follows; 1. Ceating the  Notification 2. Creating a repair order using Notificaion. and getting the repaired items in to the plant 3. Creaing and confir

  • OWB mappings to skip rows that are in error and continue processing

    OWB mappings to skip rows that are in error and continue processing. 1) Enter a record into an error log 2) Skip rows that are in error 3) and continue processing Type of information could be needed in the error log: SY_LOG_ERROR_KEY ERROR_TIMESTAMP

  • HT1695 how to add mac address to wi fi router

    I am unable to access internet through wi fi although the Wi Fi icon comes on the screen.

  • FCP Files in PP ...overall acceptance

    Did a fair amout of search, but I'm still not clear on this issue... Just upgraded to CS4 in large part because I need to bridge a huge gap I have in finding freelance editing gigs with all that raw video out there that has been captured using FCP. I

  • Help on OWB

    I have installed Oracle 9i developer suite,which installs Oracle Warehouse Builder.Now I have created the Repositary also.I wanted to develope a sample application using OWB(Which consists of say 3 tables.Emp,Dept,Salgrade).How to proceed this??Any h