Wrong display at "Pegged Requirement" on CJ20N screen

Dear Gurus,
I found that Pegged Requirement at Project Builder shows material number only the first 9 digits.
we would like to display it in full digits since we are checking material number on EXIT_SAPLOMCV_001.
Would you tell me if you know how to display Pegged Requirement correctly.
AK

We create Project like this;
- Project
--  WBS1
---    WBS2
       Network
          WBS3-1
             Activity- here components are assigned
          WBS3-2
             Activity- here components are assigned
When we select Network and click on Components button,  the item "Pegged Requirement" appears.
BTW, do you know how to attach screen shot on this thread?
AK
Edited by: Asayo Kasai on Jan 18, 2011 5:29 AM

Similar Messages

  • Wakes up to wrong display setting then quits everthing !

    Hi all,
    I have a mac mini running an updated snow leopard plugged via an adapter into the HDMI slot of my Philips 40" LCD screen. For some time now, whenever I wake up the mac mini and the TV (both of which go to sleep after a period of inactivity), the screen starts off with the wrong display setting moving from 1360 x 768 to 1600 x 900 which is a much worse picture. I can switch it back through the menu bar, and that usually works, although sometimes, it also quits any open apps so I get multiple 'unexpectedly quit' error messages. This can also happen if I use the remote to wake it up without turning on the TV.
    Any ideas how I stop this ? I have repaired permissions and also verified and repaired the hard drive and that seems to have a short term impact.
    Any help would be much appreciated.
    Ben

    See if there is a way to turn off CEC on the Philips through its menu system and see if that helps.

  • TDS certificate address wrong display ?

    Hi
    All Experts.
    I am printing TDS certificate for vendor but the address for comapny is displaying wrong on certificate however we have
    maintained a correct adrress in comapny code data.
    Can any one please let me know for TDS certificate from where this address do taken ?
    Help is required.
    Regards,
    Pankaj.

    hi,
    You can edit the address TDS certificate address wrong display
    SPRO --Fianancial Accounting or Fianancial Accounting New -- Fianancial Accounting  Global Settings -- Tax on sales and Purchases -- Basic Settings-- South Korea-- Business Places
    Enter your Comapny code then select your Business Places here you can edit address to selecting address option.
    If you are using any customized Program please check with your ABAPers either any Z table is maintained, you can also check through Progrm where address has maintained.
    Regards,
    Rama Moahn Bangaru
    Edited by: B.Rama Mohan on Jul 15, 2009 2:56 PM

  • Pegged Requirement

    What exactly pegged requirement and PIR means

    Hi Samsalish,
    Pegged Requirements:
    You can use the Pegged requirements function to retrace from any BOM level
    a) Which requirements are the source of which procurement proposals
    b) Which independent requirements (especially sales orders) are affected if a procurement proposal is cancelled or a date or
    quantity is changed on a lower level.
    IT'S Features:
    For the MRP display will be:
    a) Just the pegged requirement(s) on the highest BOM level - The system displays the requirements quantity and the input
    quantity for each requirement. The input quantity is the portion of the MRP element that is required to cover the displayed
    requirement. The input quantity is displayed in the base unit of measure of the material.
    b) The order route; that means all the requirements and replenishment elements that lie between the pegged requirement and
        the:
    MRP element
    If an MRP element contains a quantity that was not caused by a requirement from a higher level, the system displays this
    quantity separately. Quantities without source arise, if more is produced than is required because of a rounding value for the
    lot size or a fixed lot size or if procurement proposals have been scheduled manually.
    Use MD04/MD09 to access the same.
    Please follow the below link it might help you.
    http://help.sap.com/saphelp_erp60_sp/helpdata/en/f4/7d3f9344af11d182b40000e829fbfe/frameset.htm
    Regards,
    Madhu.G

  • Pegged Requirement Report

    Hi All,
    I am developing a report for pegged requirement, in that my requirement is ,
    I want to display the component number , receipt number and its quantity
    ( Similar to the results that are displayed  in MD04 ).
    I am passing header component and then am exploding its Bill Of Material,
    then for each component am getting its receipt number.
    But am not getting the desired results as shown in MD04 transaction.
    In MD04 transaction all data is getting displayed at runtime.
    can you tell me how to proceed and how to get the exact receipt number for the component as that displayed in MD04.
    Edited by: bharat tambat on Aug 22, 2008 3:27 PM
    Plz help its urgent

    Dear
    If you are lloking for custom report then you should develope based on folllowing tabels :
    1.RESB ,PBIM ,BAUGR(PEG.REQ.QTY) ,PLAUN(PL.ORD) ,AUFNR(PO), EBELN(PR)
    Or you can try MD_STOCK_REQUIREMENT_API_list  /MD_PEGGING_NODIALOG
    For standrad SAP report you need to refer CO09/MD4C/COOIS/MD07
    Hope this helps
    Regards
    JH

  • Display Entity attribute values on summary screen

    Hi,
    I have a rule base which allows the members of a household to apply for some benefits. A few documents are also required to be submitted in order to complete the application process.
    The documents may or may not be required for all the members of the household. For Example, lets assume the application asks for a disability certificate. This has to be submitted by only those who are disabled.
    I want to display the list of the members (on the summary screen) for whom a particular document is required.
    How I can get this list? I tried storing the member names in a global variable, but was not successful.
    The rule base has a separate entity to capture the household members.
    Thanks,
    Aakarsh

    Out-of-the-box in version 10 you can't attach entity level attributes to the summary screen.
    However, have a look at this thread for some alternate ideas to address what you're trying to do: Displaying Entity Level Attributes on Summary screen (Thread title: Displaying Entity Level Attributes on Summary screen)
    Cheers,
    Jasmine

  • CJ20N screen changes

    Hi,
    I have one question related to CJ20N screen modifications.
    Whenever user clicks on network beneath the WBS element, text box next to Activity number should be greyed out. That is the activity number text box should be greyed out (AFVGD-VORNR).
    How to do that with out using an access key?
    I tried putting breakpoints ine enhancement that I got by SMOD, but it never stopped there.
    Also, earlier users have added some tabs in the network screen. I want to add few custom fields on the same screen, but when I see the screen number and go to change mode it asks for access key to perform the changes.
    Please help!

    Hello @ponco,
    Welcome to the HP Forums, I hope you enjoy your experience! To help you get the most out of the HP Forums I would like to direct your attention to the HP Forums Guide First Time Here? Learn How to Post and More.
    I have read your post on how the screen changes size from very large to small, and that the mouse icon scrolls screen at times. Is this a recent or reoccurring issue? Does this same issue occur if you boot your system into Safe Mode? I would be happy to help you, but first I would encourage you to post your product number for your computer. Below is a is an HP Support document that will demonstrate how to find your computer's product number. 
    How Do I Find My Model Number or Product Number?
    In the meantime, to disable the touchscreen feature on the display, I recommend following the steps below:
    Press the Windows logo key + X.
    Select Device Manager from the list.
    Click the little arrow next to Human Interface Devices to expand the list.
    Click the touch screen driver,
    Right-click, and select Disable from the list.
    Click Yes on the dialog box that asks if you are sure you want to disable the touch screen driver.
    reference: http://h30434.www3.hp.com/t5/Other-Notebook-PC-Questions/How-to-Disable-the-touch-screen-for-HP-Pavi...
    Please re-post with the results of your troubleshooting, as well as the requested information above. I look forward to your reply!
    Regards
    MechPilot
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the right to say “Thanks” for helping!

  • Display Key Values only on filter screen

    Hello all,
    I have one specific requirement. When user runes any query (based on an infoset) , data is displayed. After which if user presses right clicks on data filed -> Select filter value. Then one  Filter screen is displayed. Values from this filter screen are displayed as text values.
    I want it to display as key value. This particular infoobject is in coumpounding.
    I have already tried changing Bex properties at infoobject level and RSD1, it does not have any effect.
    can anyone suggest any option.
    Edited by: priyanka s on Sep 15, 2008 10:41 AM

    Hi Priyanka,
    In BI 7.0, these options are available in the definition of InfoProvider itself.
    For DSO:
    Right Click on Key/Data Fields --> Provider Specific Properties of the InfoObject --> Display (Column)
    For Cube:
    Right click on Dimensions --> Provider Specific Properties of the InfoObject --> Display (Column)
    Set the required properties here and you will get the required results.
    Hope this time you get it right
    Regards,
    Yogesh

  • MRP - PEGGED REQUIREMENT REPORT

    Hi Gurus
    I have a question with regards to Pegged requirement report (MD04) and was told to analyse the up stream and down stream dependencies of a planned order. May i understand where and what is that down and up stream about ?

    Dear Alisonhar,
    Pegged Requirements  
    You can use the Pegged requirements function to retrace from any BOM level
    1.which requirements are the source of which procurement proposals
    2.which independent requirements (especially sales orders) are affected if a procurement proposal is cancelled or a date or
    quantity is changed on a lower level.
    Features
    For the MRP element selected, you can display:
    1.just the pegged requirement(s) on the highest BOM level - The system displays the requirements quantity and the input
    quantity for each requirement. The input quantity is the portion of the MRP element that is required to cover the displayed
    requirement. The input quantity is displayed in the base unit of measure of the material.
    2.the order route; that means all the requirements and replenishment elements that lie between the pegged requirement and the
    MRP element
    If an MRP element contains a quantity that was not caused by a requirement from a higher level, the system displays this
    quantity separately. Quantities without source arise, if more is produced than is required because of a rounding value for the
    lot size or a fixed lot size or if procurement proposals have been scheduled manually.
    Use MD04/MD09 to access the same.
    Also check this link,
    http://help.sap.com/saphelperp60_sp/helpdata/en/f4/7d3f9344af11d182b40000e829fbfe/frameset.htm_
    Regards
    Mangalraj.S

  • How to display a specific tab in a screen after a popup message

    Hi all,
            I've a rewuirement where in i need to display a secific tab in a screen after popping up a warning message. To be specific, when i choose 'Yes' in the popup window, it shoud take me to a tab which is not active while displaying the warning popup.
    Thanks in advance....
    Anil Kumar Japa

    Hi
    U need to active the tab you want to show:
    So you should set the ok_code (of the tab) value to field ACTIVETAB
    <TABSTRIP>-activetab = <OK_CODE>.
    And transfer the value of subscreen number to the subscreen area:
    CALL SUBSCREEN SUBSCREEN1
                 INCLUDING G_CTRL_TABSTRIP-PROG             
                           G_CTRL_TABSTRIP-SUBSCREEN.
    Max

  • Can I substitute an external display in place of broken powerbook screen?

    Water was spilled on my powerbook titanium and now the backlight doesn't work. This is fairly expensive to replace, but the computer appears to be working fine (from what I can tell using the dimly light display).
    Instead of replacing my screen which would be costly can I just use my powerbook as a desktop and attach it to the external display? Without seeing whats on the screen can I setup my computer to use the external display as the main output (mirroring)? I fear I might not be able to do this without the GUI provided by the screen.
    Anyone ever done this?
    Thanks.
    Powerbook G4 Titanium 15"   Mac OS X (10.4.8)  

    Yes, you should be able to do this no problem. You don't need the GUI. Just close the lid on the TiBook, attach and external monitor and then use and external USB keyboard or mouse to wake the system. Leave the lid closed at all times. And leave the AC adapter attached. Should work fine.

  • Display Payslip in PDF format on Screen

    Hi SAP Gurus...
    I have done the below to generate the SAP HR Reminaration statement in PDF.
      CALL FUNCTION 'BAPI_GET_PAYSLIP_PDF'
        EXPORTING
          employeenumber = p_pernr
          sequencenumber = it_rgdir-seqnr
          payslipvariant = p_forml
        IMPORTING
          return         = i_return
          payslip        = x_payslip
          pdf_fsize      = v_pdf_size.
    Now, I want to display it in PDF on the Screen.
    Please tell us how to proceed further.
    thanks in advance.
    regards,
    R R Suthar

    Dear Gurus...
    Thanks  for help.
    I have already done this,but I want to do it without using the FMs GUI_DOWNLOAD and GUI_RUN(which is obsolute).
    Instead I want to display PDF data using any other method.
    Can any body suggest how to do using class / method.
    thanks in advance.
    regards,
    R R Suthar

  • PDF display accurate page size in Full Screen Mode

    Mac G5 Tower Panther OS. When making a PDF presentation to a client (an A4 brochure for example) I would like to use the Full Screen mode using my remote to change pages and make a smooth impression. The problem is on my Apple 20' Cinema display the A4 design fills the screen when I want to show it at 100% size only (210 x 297mm). I can do this easily in Acrobat normal mode but can find no way to make this so with Full Screen mode. The screen resolution is 1680x1050 and I am reluctant to even temporarily change it because it knocks other stuff off kilter.

    I can't find how to do this anymore either.
    It was a GREAT feature.
    And now suddenly, it appears to be removed!  What the heck Apple !!!!

  • Table  for pegged requirement

    HI,
    I need to develop a report to  identify the pegged requirement against purchase requsition for the dependent requirements of low-level components. i have checked MD_PEGGING  and MD_PEGGING_NODIALOG but these FM are not suitable for my requirement. Since i need to get the sale order deatils by passing PR number.
    Please share your thoughs on this.
    Thanks & Regards,
    Renuga.A

    Yes, after running FM MD_SALES_ORDER_STATUS_REPORT or MD_stock_requirement list _API
    Fetch the data which have DELKZ "BA" -( purchase requisition) from the result of above FM
    and pass the data into FM MD_PEGGING_NODIALOG &get the relevant sale order line item

  • How to capture the DB Errors to display more specific error on the screen

    HI,
    How to capture the DB Errors to display more specific error on the screen?
    Can any one suggest on this please.
    Thanks

    hi,
    in your db package or procedure write this in ur exception handler
    as
    excpetion when others
    FND_MSG_PUB.ADD_EXEC_MSG (pkg_name, proc_name,
    substr(sqlerrm, 1, 240))
    now in your java code you can catch and throw this excpetion by using
    OAExceptionHelper.checkErrors (Tx, messageCount, returnStatus, messageData);