WRT54G2 v1 broken web-interface

Sorry my bad English.
my problem:
in router broken web interface (some elements hide / or not present) : see puctures
in pic2 you can see - upgrade button hide.. i cant upgrade or rewrite firmware.
i try:
try rewrite firmware from web-interface
try reset firmware by press reset button on backside..
try change browsers (safari opera firefox ie)
try disable (css/scripts/views) in browsers
try change conection port on router and on pc
try change station pc notebook - another notebook
try connect from other OS (ubuntu xp win7 vista)
...no result
what can i do to restore original firmware??
Solved!
Go to Solution.

solution found:
switch off power from router
then press reset button and return power
press reset button while router boot.. then open browser
router must be in managment mode.
then wrote dd-wrt VxWorksKiller-G2V1-new.bin (original firmware not work i try! ..but maybe you more happy)
after that reboot router (reconnect power wire)
and wrote main dd-wrt.v24_micro_generic.bin firmware by tftp
cd /d <firmware_folder>
tftp.exe -i 192.168.1.1 PUT dd-wrt.v24_micro_generic.bin
after that reboot router 2 times - (reconnect power wire)
and do 1  hard reset (30-30-30 method)
it help me.
dd-wrt site

Similar Messages

  • WRT54GL Web Interface Broken - Failed Firmware Update - Router Works

    I have a WRT54GL v1.1 router. I tried to update the firmware, using what I thought was the newer firmware, apparently somewhere I mislicked and didn't get what I thought I was getting. It succeeded, but now the web admin interface is totally broken. It loads, but there are no link or text, I can seem some form fields with some data, but mostly it's like seeing the page with NO content or navigation (though I can see the layout correctly). This means I can't change any of the router settings.
    My internet still works. Wireless works (I just have no way to secure it now). I have tried to usu TFTP to upload the correct drivers from this web site. It says "Cannot Connect to Server" or something like that when it tries. I have pinged the router and it works. I have tried to assign a static IP (192.168.1.100) and then have TFTP start as soon as I see my continuos ping start to get a result. It still says the same "Cannot Connect" type of message.
    I have also tried to see if the router has some kind of "Management Mode" by holding the rest button, unplugging the router, plugging it back in, waiting 10 seconds and releasing then waiting a minute and going to 192.168.1.1 and it looks like the same exact broken web interface I normally get. It doesn't appear to go to a "Management Mode."
    The power light is not blinking.
    Help!
    Screenshot of Broken Interface

    What was the procedure you followed to upgrade/re-flash the firmware through TFTP?
    As TFTP firmware upgrade was failed follow the below mentioned steps.
    Double click the TFTP.exe file and click run.
    For Server- Enter the IP Address of the router that you assigned.  By default, the router is 192.168.1.1...
    For Password- Enter the password you assigned the router. By default, the router’s password is “admin”.
    For File- Click the triple “…” button and browse for the .bin firmware file...
    Click Upgrade button to start upgrading.  A progress bar should show up to show the progress.
    Once the Upgrade is done press and hold the reset button for 30 seconds...Release the reset button...Unplug the power cable from your router, wait for 30 seconds and re-connect the power cable...Now re-configure your router...

  • Catalyst 3750 Web Interface Broken

    On a WS-C3750X-24 running software version 12.2(55)SE5 when I try to access the web administration interface with Firefox 17ESR, all I see is an empty 3x4 table with a blue-grey bar at the top and four icons in the first column: a green speech balloon with a check mark in the first and last row, and a yellow triangle with an exclamation mark in the second and third row. No text, no logo, no buttons, no links, no nothing. The yellow triangles link to a page /setup_report.htm but clicking on them just displays the same page again. It doesn't matter if I try http or https.
    If I try to open the same page with https in Internet Explorer I get a "This page cannot be displayed" error with the usual unhelpful suggestions. With http, IE thinks for a few seconds, mis-autocorrects the URL by prefixing it with "www." and then displays a blank page.
    Apart from that, the switch works fine. I can access and manage it via SSH without a problem. It doesn't log any errors.
    What can I do to get the web interface to work?
    Thanks,
    Tilman

    Hi Reza,
    thanks for your answer.
    The two commands were already in the startup and running configs. I re-entered them nonetheless. Now when I try to access the switch via https, Firefox complains: "Your certificate contains the same serial number as another certificate from this certificate authority. Please acquire a new certificate with a unique serial number. (sec_error_reused_issuer_and_serial)"
    The behaviour with http is unchanged.
    I also turned both options off ("no ip http ...") and on again. This made no difference.
    SDH
    Tilman

  • Firefox 27.0 will not allow me to have access to my web interface on my xerox 8560 mpf printer.

    I believe the loss of connectivity occurred during the firefox upgrade since I was able to address the printer's web interface earlier. The complete error message is
    Secure Connection Failed
    An error occurred during a connection to 192.168.10.102. Peer was unable to decrypt an SSL record it received. (Error code: ssl_error_decryption_failed_alert)
    The page you are trying to view cannot be shown because the authenticity of the received data could not be verified.
    Please contact the website owners to inform them of this problem. Alternatively, use the command found in the help menu to report this broken site.

    There have been issues reported caused by using some SSL cipher suites that aren't working properly with some servers.
    A possibility to test this is to disable all SSL cipher suites on the about:config page (i.e. toggle security.ssl3.* prefs that are true to false) and enable one at the time to see if you can find the culprit and keep this suite disabled and reset the other cipher suites or possibly continue testing to see which ciphers work with this server.
    Do a hard refresh of the tab with this not working page via "Ctrl+F5" or "Ctrl+Shift+R" after each change.

  • HP LaserJet 400 MFP M425dn: bug in MTU path discovery, printer reboots via web interface

     Firmware Datecode: 20121205
    1. We can not access this MFU over VPN link. Otherer devices are accessed successfully.
    As far as I understand there is an error in MTU Path Discovery.
    tcpdump logs are attached.
    Is there a way to change MTU of this device?
    2. This MFU a  reboots when I open page "Settings" of "Networking" submenu (/hp/device/set_config_networkSettings.html?tab=Networking&menu=NetSettings) if option "System" -> "System Setup" -> "Language" is "Russian". But this looks like a very good feature since I've have not found the way to reboot this printer remotely.
    Here I was tring to access web interface over VPN (IPSec), 192.168.4.135 is IP of my comp, 192.168.160.200 - is IP of MFU, 192.168.160.254 is a gateway:
    $ tcpdump -n -r printer-1.pcap
    reading from file printer-1.pcap, link-type EN10MB (Ethernet)
    17:20:29.337867 IP 192.168.4.135.54147 > 192.168.160.200.80: Flags [S], seq 2356029847, win 8192, options [mss 1460,nop,nop,sackOK], length 0
    17:20:29.338026 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [S.], seq 614551948, ack 2356029848, win 8760, options [mss 1460,nop,nop,sackOK], length 0
    17:20:29.344909 IP 192.168.4.135.54147 > 192.168.160.200.80: Flags [.], ack 1, win 64240, length 0
    17:20:29.348488 IP 192.168.4.135.54147 > 192.168.160.200.80: Flags [P.], seq 1:304, ack 1, win 64240, length 303
    17:20:29.348564 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], ack 304, win 8457, length 0
    17:20:29.378872 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [P.], seq 1:513, ack 304, win 8457, length 512
    17:20:29.379063 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 513:1973, ack 304, win 8457, length 1460
    17:20:29.379100 IP 192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    17:20:29.379103 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 1973:3433, ack 304, win 8457, length 1460
    17:20:29.379135 IP 192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    17:20:29.379251 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 1:1461, ack 304, win 8457, length 1460
    17:20:29.379272 IP 192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    17:20:29.379274 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 1461:2921, ack 304, win 8457, length 1460
    17:20:29.379304 IP 192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    17:20:29.379306 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 2921:4381, ack 304, win 8457, length 1460
    17:20:29.379335 IP 192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    17:20:29.379338 IP 192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 1:1461, ack 304, win 8457, length 1460
     This is more detailed view on some packets.
    $ tcpdump -nv -r printer-1.pcap
    17:20:29.379063 IP (tos 0x0, ttl 64, id 1, offset 0, flags [DF], proto TCP (6), length 1500)
    192.168.160.200.80 > 192.168.4.135.54147: Flags [.], cksum 0x7233 (correct), seq 513:1973, ack 304, win 8457, length 1460
    17:20:29.379100 IP (tos 0x0, ttl 64, id 62678, offset 0, flags [DF], proto ICMP (1), length 68)
    192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    IP (tos 0x0, ttl 64, id 1, offset 0, flags [DF], proto TCP (6), length 1500)
    192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 513:1973, ack 304, win 8457, length 1460
    17:20:29.379103 IP (tos 0x0, ttl 64, id 1, offset 0, flags [DF], proto TCP (6), length 1500)
    192.168.160.200.80 > 192.168.4.135.54147: Flags [.], cksum 0x5edf (correct), seq 1973:3433, ack 304, win 8457, length 1460
    17:20:29.379135 IP (tos 0x0, ttl 64, id 62679, offset 0, flags [DF], proto ICMP (1), length 68)
    192.168.160.254 > 192.168.160.200: ICMP 192.168.4.135 unreachable - need to frag (mtu 1280), length 48
    IP (tos 0x0, ttl 64, id 1, offset 0, flags [DF], proto TCP (6), length 1500)
    192.168.160.200.80 > 192.168.4.135.54147: Flags [.], seq 1973:3433, ack 304, win 8457, length 1460
    17:20:29.379251 IP (tos 0x0, ttl 64, id 1, offset 0, flags [DF], proto TCP (6), length 1500)
    192.168.160.200.80 > 192.168.4.135.54147: Flags [.], cksum 0x0c1c (correct), seq 1:1461, ack 304, win 8457,
     P.S. This thread has been moved from LaserJets to Multifunction and All-in-One - HP Forums Moderator

    John Getzke wrote:
    Its hard to understand what you are trying to do or ask here.   We have some offices connected via IPSEC tunnels. IPSEC interface's MTU is 1280 bytes (not 1500 bytes as Ethernet). All other devices successfully work over this VPN link. HP m2727 works. HP m425dn does not work. As a network administrator I've traced source of problem on all possible points and found that HP m425dn has a bug in the "Path MTU Path discovery" routine. The logs I attached shows that any packet of the TCP stream that the printer (160.200) sends to host (4.135) has "Don't fragment" flag set. According to IP standard the router HAVE TO discard the packet with DF flag set and size bigger then MTU since it can not pass a packet further without fragmentation - IPSEC MTU is 1280 bytes only while HP sends 1500 bytes. The router informs the printer about this problem with ICMP message Type: 3 (Destination unreachable) with Code: 4 (Fragmentation needed) suggesting MTU of next hop: 1280. The router does not communicate with the printer itself, it just informs the printer about network problem. According to IP standard the printer HAVE TO resend this data with the size of packet decreased according to suggested size. This is expected behavior of the Path MTU discovery routine. But the printer  sends the packet again with the same size and DF flag set. The router again discards the packet and informs printer... This cycle repeats again and again until connection is closed due to timeout. Therefore "Path MTU discovery" routine is broken at this device. It would not be a serious problem, but the printer resends packets at rate over 28000 pps (about 40 MBytes per seconds) and its CPU is so heavily loaded that it even does not respond to touches on its touchscreen. So an innocent attempt to print document on terminal server located at another office leads to inaccessibility of the printer.
     The network dump can be downloaded in PCAP format from here.

  • Integration of Web Interface of a Application in portal for external users

    Hello portal experts,
    our portal can be accessed from the internet (per ISA-Server and https). We have some applications that should be integrated in the portal.
    This application having a web interface that should be used in this context. It's easy to do this for our interal users which could access the web interface of the applications directly.
    But our requirement is to make this application accessible for our external users, too. I have tried a lot with the URL-iView and the server side fetching mode. The first page is shown but with broken images and the buttons are not clickable (Javascript not working).
    Is it possible to use the portal as a kind of proxy that would get the request from the client and forward this to the application in the intranet or is the only way to match our requirement in making the applications accessible directly from the internet? Is there any other solution?
    Best regards
    Florian

    Hi Florian,
    No its not possible to use the SAP Portal as web proxy to your other web-app.
    From my experiance I can tell you to stop searching/trying on the serverside fetching part, it wil not do wat you want.
    There is only one solution direction and that is that you place some kind of reverse proxy in front of your Portal...
    This reverse proxy solution (I keap it abstract as there are multiple solutions for this) should listen on the WWW and translate requests to the right servers.
    For example calls to "/" could be translated to "/irj/portal/" and back
    But also "/yourotherapp" can be translated to "http://yourotherappserver:port/yourotherapp and back
    Resulting in that all calls to http://yourexternalurl/ will go to SAP Portal and all requests to http://yourexternalurl/yourotherapp will go to your other app. When this works you can use the URL or Intergrater iView using the default client side fetching.
    I know that it is possible with Apache as a reverse proxy so I guess (and hope for you) that its also possible with ISA.
    Good luck,
    Benjamin Houttuin

  • Problems access to a web application (Web Interface or Web report)

    Hi,
    We found problems with the access to web application. Some users have problems with direct links to the web applications(Web Interface or Web reporting), when they click on the link an error message appears, the message displays the following text:
    "Cannot open file Bex?sap-language=ENbsplanguge=ENcmd=idoc_TE.."
    Clicking in details the message is "No Access to specified file"
    For this users the access to excel reporting is correct, the message appears when they click on the direct web links through the browser or directly in BW system, but if they type the URL they can access. Other users can use the direct web link without problems.
    I highly appreciate any help or idea about how to solve this issue.
    Thanks in advance.

    HI,
    please ask to your basis that check the language of every single user on su01 tx.
    This is the problem i think.
    Natalia.

  • Unable to capture trace, when user logs in throuigh Web Interface

    The Trace shows 'No Records Found', when user logs in through Web Interface of CRM. But there is Trace found, when the same user logs in through logon pad and carries out normal actvities.
    sufficient auth. is provided.
    Is there any setting in ST01, through which i can get trace , when user logs in through Web Interface
    Regards

    ST10 traces 1 instance only.
    Your CRM web interface could use another instance than your backend. Go to transaction SM21, choose the appropriate server and run ST10 again.
    Succes!
    Kind regards,
    Lodewijk Borsboom

  • LIST OF VALUES not Populating in BPS WEB INTERFACE ( LAYOUTS )

    Hi BI Guru's
    I have created a WEB interface for BPS in BI ( version 7.0) .  But when i execute this in internet explorer, I do not get the LIST OF VALUES for Material. 
    When I click on "input help" the system open a new window for "Value selection".  When I specify the material code, it gives me blank LIST OF VALUES.
    But it is working for other fields like Customer, UOM in the same layout.
    Please suggest some solution.
    Thanks,
    Nilesh Labde

    hi,
    Thanks for the reply.
    Master data is avaliable for the Material Code.  The problem is in Internet Explorer and not in SAP GUI .
    If i run Planning folder for the same layou in SAP GUI it is working fine.

  • ASA 5505 configured for WebVPN connecting to Citrix Web Interface

    ASA 5505 configured for WebVPN connecting to Citrix Web Interface.
    i have a ASA 5505 that I am attempting to configure for WebVPN with passthrough into Web Interface .  The user authenticates into WebVPN OK and gets the option to click on the Citrix Link (which is i add bookmark  citrix server http:// 172.30.40.5.) i enter the citrix and then for example  i want to open to outlook it can not open. (when i want to open some application no application is open)).there is no alarm at asa. how i solve this issue?
    thanks.

    Teymur,
    Can you confim that after disabling the ssl/tls on the Citrix server (secure connectivity) that you are getting exactly the same error.  It is possible that it is generating a different error.
    The bug where we have see the existing error was CSCtf06303 but that has been fixed in 8.4.1.  Can you confirm the exact version of code you are running on the ASA.
    If you have confirmed the above two notes it may be adventageous to open a TAC case as we may need to do some live additional troubleshooting.
    Thanks
    -Jay

  • Distortion in Save For Web interface

    I am still having problems with my Save For Web interface. Attached is a screen where you can see that with just the Optimized view showing (in this case 72%), the picture looks as expected. But if I go to 2-up or 4-up views, the 2nd image (which was the 72% Optimized) is now all pixelated as if it were a GIF.

    OMG!  How many years have I been using this program and I have never noticed this until now?!?
    Sorry for the brain fart and thanks for pointing that out!!! 
    I am really having a good laugh at myself about this one!
    Jules

  • Cisco AP 1131AG Web Interface Problem

    Hello,
    I purchased two Cisco access points (model AIR-AP1131AG-A-K9) from a seller on eBay. The Access Points power up fine and are able to get an IP address (I can see the AP's MAC address on my router), but it won't let me connect to the web interface to manage it. I have tried using different browsers, but they all say something along the lines of "The page could not be found" when I enter the IP address into my browser. No login screen, no nothing: just a time-out error.
    When the Access Points are powered on, the Ethernet and Radio lights start out green, but then the Ethernet light stays green and the radio light flashes amber and the two alternate being lit. The status light on the outside of the Access Point goes from green to orange to red and back again, looping infinitely.
    Any ideas what could be wrong? Thanks for any and all help in advance! (Please let me know if you need more information; I don't ahve the AP's with me, but I will be home in a few hours and can respond then.)

    do a show cdp neighbor detail on the port the AP is connected to.  Take a look at the software that is running, IOS will show k9w7, and lightweight will show k9w8.
    if it''s k9w8, you'll need to convert them back to IOS
    http://www.cisco.com/en/US/docs/wireless/access_point/conversion/lwapp/upgrade/guide/lwapnote.html#wp160918
    HTH,
    Steve
    Please remember to rate useful posts, and mark questions as answered

  • Displaying a BW query in web interface

    Hello People ,
    I am trying to see a BW query in a web interface . I will tell you how am I doing it . I run the transaction RRMX which opens an excel sheet and gives me a tol bar from which I open a query . Then I choose info areas from the next window and it shows me a tree structure with two nodes
    1) Financial
    2) Industry sectors
    I expand industry sectors > retail > staff works
    This takes me to two nodes
    1)       operational
    2)       sales infocube
    I expand sales infocube and this takes me to a couple of nodes
    1)       Key business driver
    2)       Manager forcasted sales
    3)       Productivity data source
    4)       ….
    5)       ….etc
    I select key business driver and choose the “CHANGE” icon from the toolbar . This opens the query designer . There I have an icon in the toolbar which says “display quey on web” . I click that and it attempts to display the query in internet explorer .
    Now the problem is the the message that appears on the browser is
    Warning sign : variable OFPER for characterstic fiscal year/period has been converted to required entry .
    Error sign : Error when generating data provider .
    Now my question is what does this message mean ?Does this mean that the required content that I am trying to access has not been activated or there is some configurational issue ?
    Regards
    Deepak Singh

    Hi Deepak,
    It means that there is a selection screen for Fiscal period in which you have to enter the Fiscal Period. Only for the Fiscal period for which you entered the data would be displayed.
    But the best way to create teh web report is to goto Web Application Designer -> Drag and drop the "Table" webitem on the right hand side -> Assign the Query to the web item. Now execute it in browser from the Web Application designer. Copy the link and use it whenver you want it.
    Bye
    Dinesh

  • BPS_WB-Can i add a query to a Web interface tabpage?

    Dear experts,
    In a BPS web interface application, i have already a tab page which allows users to input their data. Now i would like to add a second tabpage which allows to display the existing data.
    Is that possible to link a BEX query to a Tabpage BPS web interface application? I would like that the query is launched and the result is displayed each time an user click on this tabpage.
    Thanks in advance.

    Include your query in a web template and follow the approach given in the link http://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/a861d590-0201-0010-248a-fc70d8d29f26
    Edited by: Deepti Maru on Nov 30, 2010 10:24 AM

  • Executing the planning function while opening the web interface

    hello all,
    I have created a planning area based on multiprovider.This multiprovider is based on two transactional cube ie,COPA cube and Cost Center cube.
    This planning area is meant for enabling integrated planning.One plans in COPA cube and other plans in Cost Center cube the income statement gets planned based on this two.
    I selected planning items in multiprovider layout to display the income statement.The layout is as follows:
    <b>PlanningItem</b>  <b>Amount</b>
    Net Sales<b>:</b>    9.000,00 INR   (This comes from COPA)
    Sales Overheads<b>:</b> 200,00 INR  (This comes from Cost Center)
    Depreciation<b>:</b> 200,00 INR (This comes from Cost Center)
    Other Expenses<b>:</b> 300,00 INR  (This comes from Cost Center)
    EBIT<b>:</b> 0,00 INR
    Interest Income<b>:</b> 0,00 INR
    Interest Expense<b>:</b> 0,00 INR
    Operating Income<b>:</b> 0,00 INR
    Taxes<b>:</b> 0,00 INR
    Now EBIT planning item is to be calculated from the planning items as follows:
    EBIT = Net Sales-Sales Overheads-Depriciation-Other Expenses
    For this i have created a planning function which calculates EBIT.This function works properly,there are no issues in it.
    My problem is that i want this function to be executed as soon as i open the web interface for my planning application and the result should be as follows:
    <b>PlanningItem</b>  <b>Amount</b>
    Net Sales<b>:</b>    9.000,00 INR   (This comes from COPA)
    Sales Overheads<b>:</b> 200,00 INR  (This comes from Cost Center)
    Depreciation<b>:</b> 200,00 INR (This comes from Cost Center)
    Other Expenses<b>:</b> 300,00 INR  (This comes from Cost Center)
    EBIT<b>:</b> 8.300,00 INR
    Interest Income<b>:</b> 0,00 INR
    Interest Expense<b>:</b> 0,00 INR
    Operating Income<b>:</b> 0,00 INR
    Taxes<b>:</b> 0,00 INR
    Can anybody suggest how to go about this problem?
    Thanks in advance.
    regards,
    Yogesh

    Hi Yogesh,
    as far as i know, there is no standard functionality for that purpose, but there are workaround for it.
    1. Modify the BSP Application.
       Go to SE80 --> Repository Browser --> BSP Application --> your WI name --> page with flow logic --> double click on page1.htm --> Event handler tabstrip --> on the drop down selection press F1 --> add a function module that call you BPS function in specific event (e.g: OnInitialization).
    2. Use WI-Exit Class / WI-Extention (ABAP OO).
    Here you need to create sub class from Class: CL_UPWB_BSP_APPL, and assign the class to your WI. You can then add a function module that call you BPS function in method:
    2.1. Load --> performed only once on intial execution of WI.
    2.2. Initialisation --> called once for each server response.
    2.3. Dispatch --> called at each action and also for each WI component.
    You can see further information in SAP how to paper:
    How to Validate manual input in WEB planning application, New BPS-Features delivered with SAP BW 3.5, etc.
    You can call your BPS function with BPS API FM (See F.Group: UPC_API)
    But there is also more easier way to realize your ebit calculation. If you define your EBIT calc. manually in layout (define with manually defined Lead column). With this way, You will always get your EBIT analog with inputed values.
    Then you add your EBIT calc.function to Layout Component in WI in property: 'Function After Data Change'.
    Best Regards,
    Suan Liono

Maybe you are looking for