Xcelsius/Webi iView

All,
Issue 1
I am looking to view a BOBJ Webi Reports, Xcelsius Dashboards based on BI service and BW connection within the Portal iView, Based on the documentation available I have not been able to create a URL, KM Navigational or find a standard Xcelsius/ Webi iView that would display a BOBJ Xcelcius/Webi Report directly onto the portal.
Issue 2
I have been successful creating a KM Navigational iView that displays the folder structure as viewed within the info view. However all the folders showup in the KM Navigational iView even though when I login to infoview only 2 folders are assigned to my users and only 2 folders showup in the infoview.
Any help would be appreciated.
Toor

take a look here:
Portal Part 1
/people/ingo.hilgefort/blog/2010/03/29/sap-businessobjects-enterprise-sap-enterprise-portal--part-1-of-4
Portal Part 2
/people/ingo.hilgefort/blog/2010/03/30/sap-businessobjects-enterprise-sap-enterprise-portal-part-2-of-4
Portal Part 3
/people/ingo.hilgefort/blog/2010/04/08/sap-businessobjects-enterprise-sap-enterprise-portal--part-3-of-4
Portal Part 4
/people/ingo.hilgefort/blog/2010/04/21/sap-businessobjects-enterprise-and-sap-enterprise-portal--part-4-of-4
Ingo

Similar Messages

  • Slow response when using Xcelsius web service connection witn input values

    We've been very successful in using the Xcelsius Web Service Connection. We've recently moved forward toward using input values when calling a web service and having issues with response time. Without input values, it takes 3 - 6 seconds to retrieve and display the results in Xcelsius, but, when using the input values to the web service, it takes about 27 seconds for Xcelsius to retrieve and display the results.  Does anyone have experience with fixing slow response associated with using input values for a web service connection?

    Hi Sharone,
    What's the version of your Xcelsius and BOBJ server?
    I'm asking because using the last version of BOBJ server (BOXI 3.1 SP 3) you have new services on CMC just to help Xcelsius to work better with WebServices.
    Regards,
    Rodrigo.

  • BEx Web iView displays graph only after page Refresh

    Dear Friends,
    I am facing problem in BEx Web application iView.
    I am using the SAP Standard BEx Web iView template to call BI Report by passing parameter as below
    com.sap.ip.bi.bex?TEMPLATE=ZSD1_WR_TREND_HY
    URL is Link[http://<hostname>:52000/irj/servlet/prt/portal/prtroot/pcd!3aportal_content!2fcom.sap.pct!2fplatform_add_ons!2fcom.sap.ip.bi!2fiViews!2fcom.sap.ip.bi.bex?TEMPLATE=ZSD1_WR_TREND_HY]
    The report got 2 graphical representations along with a table data.
    Problem is the graphs displays data representation only after refreshing the page.
    Infact the problem exists in production system and works fine in Development system.
    When I checked from portal prospective I found no difference.
    Can anybody help on this.
    Thanks in advance.
    Lakshmikantha

    hi,
    find the iview from the content administration menu in portal.
    If you are using a standard role open the role
    and trace the pages until you find the iview containing the template.
    Open the iview and check the parameter Content-BW report.
    At the field BEx Web Application Query String go to and and check the template name.
    Go to web application designer and open the above template.
    Change the parameters from the post above and save the web template as zXXXXX.
    Change the web template at iview as well.
    What i figured out is that bex handler has a problem creating an array when you are using same session for more than one charts.
    When you use seperate sessions for each chart there is no need for array creation and works just fine.
    *If you are using best practices go to Content Provided by SAP->Specialist->Best Practices and find the role and iview you are using.
    It should work..

  • FPN Remote Delta Link - Bex Web - Iview Preview Error

    We created a remote delta link in the Consumer Portal for Bex Web Iview from the Producer portal. The preview of the iview in the consumer portal fails with the following error:
    Unexpected error - Unable to get IView: fpn:<Consumer Alias> /pcd:portal_content/com.sap.pct/platform_add_ons/com.sap.ip.bi/iViews/com.sap.ip.bi.bex:eV%2BqDnR62S5rnG4nJ%2F7uhw%3D%3D:1
    In the default trace of the Producer we see the following:
         at com.sap.engine.core.thread.impl3.SingleThread.run(SingleThread.java:176)
    Caused by: com.sap.portal.fpn.exception.base.FPNFatalErrorException
         at com.sap.portal.fpn.runtime.FpnRuntimeService.doFpnLookup(FpnRuntimeService.java:171)
         at com.sap.portal.fpnprovider.fpn.GenericContext.lookup(GenericContext.java:48)
         at javax.naming.InitialContext.lookup(InitialContext.java:347)
         at com.sapportals.portal.prt.deployment.DeploymentManager.getPropertyContentProvider(DeploymentManager.java:1919)
         ... 40 more
    Caused by: com.sap.portal.fpn.exception.base.unchecked.FpnCommunicationException: Cannot retrieve delta link remote state for remote path 'pcd:portal_content/com.sap.pct/platform_add_ons/com.sap.ip.bi/iViews/com.sap.ip.bi.bex' with user Id '<BIUSER>'
         at com.sap.portal.fpn.remote.AccessServiceImpl.retrieveDLRemoteState(AccessServiceImpl.java:158)
         at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
         at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:39)
         at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
         at java.lang.reflect.Method.invoke(Method.java:331)
         at com.sap.engine.services.rmi_p4.P4DynamicSkeleton.dispatch(P4DynamicSkeleton.java:159)
         at com.sap.engine.services.rmi_p4.DispatchImpl._runInternal(DispatchImpl.java:330)
         at com.sap.engine.services.rmi_p4.DispatchImpl._run(DispatchImpl.java:201)
         at com.sap.engine.services.rmi_p4.server.P4SessionProcessor.request(P4SessionProcessor.java:137)
         ... 6 more
    Caused by: com.sap.portal.fpn.exception.base.unchecked.FpnAuthenticationException: Could not find user from the user id '<BIUSER>'
         at com.sap.portal.fpn.protocol.marshal.ContentMarshallerService.marshalDLChain(ContentMarshallerService.java:294)
         at com.sap.portal.fpn.remote.AccessServiceImpl.retrieveDLRemoteState(AccessServiceImpl.java:156)
         ... 14 more
    Caused by: com.sap.security.api.NoSuchUserException: USER_AUTH_FAILED: User account for logonid "<BIUSER>" not found!
         at com.sap.security.core.imp.UserFactory.getUserByLogonID(UserFactory.java:1317)
         at com.sap.security.core.imp.UserFactory.getUserByLogonID(UserFactory.java:1339)
         at com.sap.security.core.imp.UserFactory.getUserByLogonID(UserFactory.java:1354)
         at com.sap.portal.fpn.protocol.marshal.ContentMarshallerService.marshalDLChain(ContentMarshallerService.java:292)
         ... 15 more
    Producer Portal - User data source is BI ABAP Backend
    Consumer POrtal - User data source is LDAP
    I have tested SSO both ways and it works:
    Logged in to Consumer -> switched URL to producer --> switched back to consumer
    Still looking at the default trace it looks like some how the end user is not recognized during the switch.
    Any help/direction  is much appreciated.
    Thanks
    Shabna

    Dao, 
      Thanks for taking the time.
    Versions:
    Producer BI portal - NW 7.0 EHP1 SP6 (BI_JAVA SP8 Hotfix 12)
    Consumer Portal - NW 7.0 EHP1 SP7 (BI_JAVA SP8 Hotfix 12)
    BIUSER exists on both:
    Producer - BIUSER is an ABAP user in the BI Backend
    Consumer - BIUSER is the SAMAccount Name of AD account BISUER@<company.com>
    SSO works both ways.
    I checked the thread you mentioned. Though the error in the default trace is the same, I am using FQDNs everywhere and the correct P4 ports. I am able to telnet using the P4 ports between the two portals. The FP connection tests also work.
    Thanks
    Shabna

  • Portal & Webi iView Question

    Hi Experts,
    Are there predefined iViews (templates) available for Webi documents/reports?
    If yes, how do I obtain the iviews, and could you please provide a step-by-step on how to view Webi reports on the Portal?
    Thanks for your help in advance.
    tvu

    Hi ,
    Yes there are predefined iViews for WebI. you can use Url iviews for this.
    you need to defind Source Url and Url parameters.
    Refer below wiki :
    [http://wiki.sdn.sap.com/wiki/display/BOBJ/CreateURLiviewintotheSAPEP+portal]
    Regards,
    Khushboo

  • SSO issue when Webi Iview is viewed from consumer portal

    Hi,
    We have our BI Portal federated to another Portal. I have a Web Intelligence report iview created in our producer Portal using Open Doc link in an URL iview. It opens perfectly fine when viewed in the producer portal. But when the same Iview is viewed from the consumer portal, SSO doesn't seem to work. I get the following error when the Iview is opened,
    Account information not recognized: Logon ticket could not be validated by system BM7CLNT100. Message: TICKET_ENCODING_ERROR. Ticket/logon string: AjExMDAgAA9wb3J0YWw6UEFSQVgwMjWIABNiYXNpY2F1dGhlbnRpY2F0aW9uAQAIUEFSQVgwMjUCAAMwMDADAANF
    RDcEAAwyMDEwMDkyOTE1NDIFAAQAAAAICgAIUEFSQVgwMjX/AQUwggEBBgkqhkiG9w0BBwKggfMwgfACAQExCzAJBg
    UrDgMCGgUAMAsGCSqGSIb3DQEHATGB0DCBzQIBATAiMB0
    xDDAKBgNVBAMTA0VENzENMAsGA1UECxMESjJFRQIBADAJBgUrDgMCGgUAoF0wGAYJKoZIhvcNAQkDMQsGCSqGSIb3D
    QEHATAcBgkqhkiG9w0BCQUxDxcNMTAwOTI5MTU0MjM1WjAjBgkqhkiG9w0BCQQxFgQUcqdcKGLWYPOuXMqwm!cXEQxMX
    t8wCQYHKoZIzjgEAwQvMC0CFD7tYQD9VjOPYK/!7UwY28KoWoGEAhUA5n4BVetumsFn3i!KpivWTDqlRYM=
    This message appears above the BO Infoview login screen. The userid part is pre-populated with my user id.
    BM7CLNT100 is our producer portal. BEx Iviews are working fine from consumer portal. Am I supposed to pass any extra application parameter? Could you please help me out with this issue?
    Thanks,
    Ashwin

    Hi Keshari,
                Thanks for the reply. Both the links you have mentioned are problems that I am not facing. I have no SSO issue in the producer portal. It logs me in and takes me directly to the Webi report. I have the error occuring only when I try to access this report from the consumer portal exposed as remote role.
                This is the path it is taking.
    consumer portal to producer portal (SSO) - working
    producer portal to BO (SSO) - working
    but consumer portal to BO through producer portal - not working
    Thanks,
    Ashwin

  • Xcelsius Web

    Hello friends,
    I've created an xcelsius report using Analyser and posted it on the Web.
    I've few questions in this context.
    1. after we create the report and remove the formulas from the sheet, ( this is after I disconnect the connection in "Manage Connections" of Xcelsius Analyzer tab), i'm able to check the "Preview".
    But as soon as I create an epm connection using "Manage Connections" of Xcelsius Application tool bar, i'm unable to see the preview.
    i.e. click on preview shows a screen...."Initializing" and nothing happens
    Please help
    2. second issue is while i create a web page after uploading the exported flashfile to the Content Library as a document .
    I'm unable to view the "Preview" on the web.
    I believe solving first issue would resolve my second one...
    Kindly assist me..

    Can you tell me the version of the following products on your machine?
    Analyzer and EPM Connector
    Xcelsius
    I specifically need to know the Service Pack level for each.
    There was an issue with SP 3 of Xcelsius that made it hang with a message "Initializing..."  being displayed.
    This was fixed in FixPack 2. If you apply this FixPack (or higher) this issue should go away. Also ensure that you have SP6 of the Extended Analytics Analyzer plugin installed as well.
    Edited by: Sean Johnson on Nov 1, 2010 8:26 PM

  • XCelsius + BICS + Publish to EP + BEx Web Application Designer

    Dear Friends,
    Any one have idea about how we can publish an XCelsius Dashboard (with BICS connectivity) to the SAP Enterprise portal using Bex Web Application Designer?
    I tried to publish the dashboard using the iView, by following the below link.
    http://wiki.sdn.sap.com/wiki/display/BOBJ/IntegrationofanXcelsiusdashboardinNetWeaverEnterprisePortal
    Since it can only support individual report, I can not use this option in my client.
    Appreciate your help to provide me the information how we can publish the dashboard using Bex Web Application Designer.
    Thanks & Regards,
    Ajish George

    Hi,
    Did creating the iView using the instructions in the link work for one Xcelsius report?  Can you explain what you requirement is or expand on your comment "Since it can only support individual report, I can not use this option in my client.".  One iView can only launch one object.  If you have multiple BW connected XC files to launch I think that you will have to create multiple iViews with the "DASHBOARD=" each XC file value in each iViews  BEx Web iView query string parameter  setting.
    If you only want one link off of your Portal then you could create a BW 7.0 Web application where you could use objects like buttons to launch each individual URL string for the seperate dashboards.  The challenge with this would be that your URLs would be static and if you are using a regular BW landscape, DEV / QAS / PRD, then you would need to employ logic find and  update the system part of the URL.  I am not sure how this would be done, but it would probably require JavaScript.  If you do report development in your PRD system this would not be an issue.
    From a support perspective I would suggest using a container iView to group your XC reports together and then create a seperate iView for each XC report.  This eliminates dealing with the system identifier as the Portal enviroment manages this as the objects are transported through the systems.  A container iView with the action iViews in it would look like a menu structure on your Portal.
    Rgds,
    Mel

  • Update/insert/delete data from xcelsius to Database via web service

    Hi,
    I need to create dashboard that go function can <b>update/insert/delete</b> data send to <u>Database</u> thru <u>web services</u>, as i know got 2 xcelsius add-on software which support those of function <b>InfoBurst</b> and <b>flynet </b>
    <b>InfoBurst</b>
    http://www.infosol.com/azbocug/minutes/4-Writeback%20to%20a%20Database%20with%20Xcelsius.pdf
    <b>flynet </b>
    http://www.flynetviewer.com/public/community/Blogs/FlynetXcelsiusServerUser/default.aspx
    Except this 2 purchase add-on xcelsius, any other solution ?  
    Maybe need to write some in MSSQL or C# programming which enable insert, update, delete ...etc  ?
    *note: i not use Xcelsius Engage Server , i use Xcelsius Engage only
    thanks,
    regards
    s1
    Edited by: Leong Pui Kee on Mar 1, 2011 6:06 AM

    Hi,
    As of now in Xcelsius/Dashboard Design there is no feature or functionality to insert/update/delete data from database.
    Solution:
    Create a Web service in let’s say C# or Java, which will perform insert/update/delete operation.
    In Xcelsius add Web Service connection and user above web service.
    Xcelsius Web Service connection provides option to pass input values to a Web Service (Input Pane) and get the result (Output values pane).
    We can pass values to be written to the database as a input to Web Service via Web Service connection from Xcelsius and write data to the database.
    Note:
    Performing delete operation from Xcelsius Dashboard could be risky and may delete important data from database. I would not prefer giving delete option/functionality in Xcelsius dashboard.
    Hope this helps!
    Thank you.
    Regards,
    Vinay Mhaske

  • Web service URL configuration for Xcelsius in BO XI3.1

    Currently we can evaluate the BOE R2 and BOE XI3.1, and we are facing such a problem:
    In R2, we configure the Web service URL for Tomcat in "...\Tomcat\webapps\businessobjects\enterprise115\desktoplaunch\WEB-INF\web.xml
    ", there is a parameter called "crystalxcelsius.webconnectorurl", we configure it like this:
    <context-param>
            <param-name>crystalxcelsius.webconnectorurl</param-name>
            <param-value>
                 http://XX:8080/dswsbobje/qaawsservices/queryasaservice
            </param-value>
    </context-param>
    How can we do the same configuration in BOE XI3.1?
    We cannot find the same web.xml because the folder structure has changed.
    After we deployed the Xcelsius dashboards from BOE R2 to BOE XI3.1, it failed and the error message shows:"Unable to load URL...".

    The Xcelsius team is investigating this issue. We'll update you when possible. Meanwhile here is a suggestion from another user.
    "The web service url setting was removed from XI R3 due to the changes in InfoView/CMC client action framework in XI R3. In XI R3, there are multiple web.xml files instead of just one web.xml. The parameters defined in Xcelsius' web.xml cannot be accessed by Crystal Report or WebI...
    Anyway, I have a workaround might work (I never tried it myself). In Xcelsius design time, add a flashvars range name "CEWebServiceURL" and bind the value of this range to a cell that has the url of the web service you want to use at run-time. The SWF should use this url to refresh LiveOffice at run-time."

  • Xcelsius vs Webi Rich Client

    If in a SAP implementation project BI reports are being designed using BEx Query Designer, is it necessary/mandatory that the BO reports i.e. Dashboards should be designed using Webi Rich Client tool, or can it also be possible using Xcelsius 2008  (formerly) now SAP BO Dashboards.)

    Hi,
    BO consultant can design & work on  both Dashboard's & webi reports not only these need to work on other tools also like UDT,IDT, OLAP ,QAWS,Crystal Reports etc.
    Business req & type of user : either report need to shown for
    1. High level mgt ( Dashboard's)
    2.Middle level mgt
    3.Low level mgt
    (Refer above link )
    Till now I have very much user friendly with Xcelsius , so should I continue with Xcelsius or start doing R & D on Webi Rich client, so that if at all in the future it is required, it will make my work comfortable :
    For this i explained it purely depends on Business requirement .
    Mostly as a BO consultant need to be Familiar with all Reporting tool's (Xcelsius,webi,Crystal,Olap etc)
    Thanks.

  • Error when geeting the WebI report into Xcelsius using LiveOffice

    Hi All,
      I am using Xcelsius 2008 SP2 and Live Office. I run the report in the WebI and I am trying to get the report into Xcelsius using the live office. When I go to live office and select web intelligent I  am able to see the report it the InfoView but when I go to next step to insert into live office I am getting the below error "
    An error occurred when an object was selected in the report part viewer.(LO 02026)
    Maximum character output size limit reached. Contact your BOBJ administrator(Error: ERR_WIS_3072)".
    Could any one please help me.
    Thanks
    Muvva

    Hello Raghavendra,
    What is the size of the WebI report? There may be a limitation to the rows of data you can pull into Live Office.
    If this is the issue, you can avoid it through an alternative connection method called the [Xcelsius Web Intelligence Integration Suite.|http://antivia.com/products-xcelsius.stm]
    You can use this to connect Xcelsius directly to WebI, without the need for Live Office.

  • Xcelsius 2008 - Known Issues (Installation)

    AA: Area Affected
    PD: Problem Description
    WA: WorkAround
    AA: Installing QAAWS from BOE Client
    PD: The Query As A Web Service (QAAWS) application has been combined with the BOE XI 3 BusinessObjects Client application. It was previously a separate application.
    This means that to use BOE XI 3 QAAWS with Xcelsius 2008, you must download the BOE XI 3 BusinessObject Client from the Business Objects Support site and install it on your client machine.
    WA: To install QAAWS download the BOE XI 3 BusinessObjects Client. You may or may not have access to this download based on the type of licensing agreement you have with Business Objects. Note that the BOE XI 3 BusinessObject client is about 600MB in size.
    AA: Installing Xcelsius 2008 when a higher version of the Adobe Flash Player exists
    PD: The Xcelsius 2008 installer will install a version of the Adobe Flash Player. If you have previously installed a higher version of the Flash player, you will get a warning message from the Xcelsius 2008 installer.
    WA: You can ignore this warning message. Your newer version of the Flash Player will not be changed.
    AA: Installing Xcelsius 2008 with other older BOE products.
    PD: After installing Xcelsius 2008 on a machine, some other older BOE products on the same machine stop working (eg. WebI Report Server, BOE XIR2)
    WA: Many BOE products share the same installer, as a result installing Xcelsius 2008 on the same machine other older products changes the default install folder to the newer BOE folder. For example with BOE XIR2 it changes the default BOE install directory to change to BOE XI 3 folder.
    C:\program files\business objects\businessobjects enterprise 11.5\" is changed to
    C:\program files\business objects\businessobjects enterprise 12\"
    The workaround is to manually edit the registry and change the key folder name back to its previous name.
    Use regedit to view the folder name in the key "HKEY_LOCAL_MACHINE/Software/Business Objects/Enterprise/InstallRoot/Path".
    Double-click on path and change the Value data. In most cases the folder name is C:\program files\business objects\businessobjects enterprise 11.5\
    Note: please back up your registry before making any changes.
    AA: Uninstalling Live Office XI 3 from a machine with Xcelsius 2008
    PD: If you uninstall Live Office XI3 on a machine with Xcelsius 2008 also installed, the Xcelsius Keycode Expiry dialog box (License manager) pops up asking for the Xcelsius Keycode.
    WA: The Xcelsius keycode must be entered again to re-enable Xcelsius.
    AA: Installing Xcelsius with Office XP
    PD: Currently installing Xcelsius 2008 with Office XP is not supported due to a bug. Use Office 2003 or Office 2007 instead. If Office XP must be used see the workaround.
    WA: As a workaround to the issue of Xcelsius 2008 not installing with Office XP, users can manually add a registry key to enable installation. Please make a backup copy of the registry before making any changes.
    1. Go to Start > Run. Start the registry editor by entering 'regedit'.
    2. Select the folder HKEY_LOCAL_MACHINE and navigate to \Software\Microsoft\Office\
    3. Create an 11.0 folder, if it doesn't exist, by selecting Edit > New > Key from the menu.
    4. Create a subfolder called PowerPoint
    5. Create a subfolder under PowerPoint called InstallRoot
    You should now have the folder structure listed below:
    HKEY_LOCAL_MACHINE\Software\Microsoft\Office\11.0\PowerPoint\InstallRoot
    6. From the InstallRoot folder create a string value called "Path" by selecting Edit > New > String Value
    7. Select the newly created Path value and select Edit > Modify.
    8. Under the Value Data field enter "C:\Program Files\Microsoft Office\Office11\"
    9. Click OK.
    10. Exit the registry editor.
    11. Reboot your machine.
    You should now be able to install Xcelsius 2008.
    AA: Creating a Web Part for SharePoint Portal Server 2007
    PD: The current Xcelsius Web Part installer Setup.exe does not work with SharePoint Portal Server 2007.
    Note: Sharepoint Portal 2003 is supported.
    WA: You can manually install the web part to use with Microsoft SharePoint Portal Server 2007. Microsoft does not provide a mechanism to build a Web Part installer for SharePoint 2007. For instruction on manual installation see the Xcelsius Support website. (see follow up post below)

    The current Xcelsius Web Part installer Setup.exe does not work with SharePoint 2007 (Windows SharePoint Services 3.0). Here is the workaround to install Web Part in SharePoint 2007 manually.
    The easiest way to install a web part in SharePoint is to add the web part assemblies to Global Assembly Cache. To do so:
    1. Download and unzip the attached Xwp.zip. Drag Xwp.dll and ICSharpCode.SharpZipLib.dll into C:\WINDOWS\assembly folder on the machine running SharePoint 2007.
    2. Open web.config file located in the root of a Windows SharePoint Service 3.0 Web Application directory with Notepad. Normally, the physical location of the default WSS 3.0 Web Application root is C:\Inetpub\wwwroot\wss\VirtualDirectories\80.
    [Click here for more information on how to Find the Web Application Root|http://msdn2.microsoft.com/en-us/library/ms474356.aspx].
    3. Insert the following <SafeControl> tag between <SafeControls> and </SafeControls>.
    <SafeControl Assembly="Xwp, Version=1.0.0.0, Culture=neutral, PublicKeyToken=7e58495f1a9ea430"
    Namespace="CrystalXcelsius.SharePoint.WebParts" TypeName="*" Safe="True" />
    4. In SharePoint Portal Site Home page, from Site Actions drop-down menu, go to Site Settings->Modify All Site Settings. Click Web Parts under Galleries to open Web Part Gallery Page. Click New to open New Web Parts page. Check CrystalXcelsius.SharePoint.WebParts.Container checkbox and click Populate Gallery. Once it is populated, you will be able to add Container web part to your web part page in SharePoint 2007.

  • How to use "global variable" in Xcelsius ?

    HI experts,
    In our projects, many Xcelsius web pages on BusinessObjects enterprise may have the same year/month variable related to present, for example, 2009/02.  We want use this varible when the user open any Xcelsius web page. Can this be implemented by session value?
    Thanks!

    Hello,
    Could you explain what did you mean ?
    Did you manage to use a variable when running Xcelsius by using XML data ?
    Thanks,
    Daphna

  • Xcelsius based on BEx query. Issue when transporting from DEV to PRD

    Hi all,
    I am facing an issue as described below:
    I created dashboard based on bex query in Query Browser. Everything is working find in DEV. Then I transport the dashboards to PRD, I also use the override settings to point from BOD-BWD to BOP-BWP, my connection changed accordingly. Everything seems ok. One day when we stop the BOD system. Dashboards in BOP are not working. Then I start BOD, everything is ok then.
    The issue I got:
    Internal: BOP....
    External: BOD.../XcelsiusWebServices.
    Is there any chance that dashboard in BOP using the BOD xcelsius web service?
    I have resolved this issue by:
    - Open the dashboard in BOP, then in each of the query in Query Browser, I clicked edit and click next, next until end.
    - Then re-save to BOP, then it is working
    For your information, I used BEx query in Query Browser only, not use BIWS.
    Dashboard 4.0 SP04
    BW 7.3
    Does anyone face this issue before? And how you resolved it? Please kindly share with me.
    Thanks,
    Quan Vo.

    Hi Quan,
    Found few points regarding this.Please check might help you.
    Migration of Dashboards (using Query Panel) on BI 4.0 environment - Business Intelligence (BusinessObjects) - SCN Wiki
    Regards,
    Javed

Maybe you are looking for

  • User file in trash

    I was recently doing some house cleaning and getting rid of user accounts that have spotty activity. In the process I trashed one of my user accounts that had all my photos and lotsa stuff I STILL NEED. The account folders are still in the trash. How

  • Dump in field symbol assigen

    Hi , i try to do this statement and i have dump BEGIN OF tt_agr ,         agr_name TYPE agr_name,         text TYPE agr_title,        END OF tt_agr . FIELD-SYMBOLS: <ls_retr_txt1> TYPE tt_agr. LOOP AT lt_help ASSIGNING <ls_help_value>.     SPLIT <ls_

  • Do long texts always split up?

    There is no character counter when I text. Will too long texts always break up into multiple texts, regardless of receiving carrier?

  • JDev 10.1.2.1: Server Error 500: Model binding context not initialized

    We're migrating from 9.0.5.2 to 10.1.2.1. The UIX application supports dynamic JDBC credentials through our own binding filter. This ran fine in 9.0.5.2. Now, when the app starts, I get: java.lang.RuntimeException: Model binding context not initializ

  • Why doesn't my firefox support latest version of IDM ?

    m working for golalaa.net and while i want to download some files or backup of cpanel then tend to use idm but what to do in order to be able to download my backup using it ? ''Title edited by a moderator.''