can we do <b>xml to EDI</b> without any EDI adapter like SEEBURGER or GENTRAN?
and just with Conversion agent?
if so ,would it be a xml to file scenario?please explain little about the process.
thank you,
regards,
Babu
Amir,
I was trying to add some comments what I felt.
I mean,with Conversion Agent we cant send or recieve EDI documents. and we can use it for just to get the structure of the EDI document as XSD with Conversion Agent which we want to use in mapping.And once we have structure for the EDI document we can use a file adapter and can generate XML files.
And we do mapping only, if we don't have predelivered mapping( Seeburger provides some mappings for standard document sets).
I am sorry ,if I am still unclear.
and to your comments above
>>"you may also use conversion agent from Itemfiled,it much like seeburger and i guess now its owned by SAP itself"
Seeburger has lot of features than Conversion agent.
Conversion agent just can get xsd from EDI structure and EDI structure from xsd,correct?
Similar Messages
-
Idoc texting without any EDI or EAI
Hello,
I have a text file to test in SAP with the following IDOC DEBMAS05.
Does somebody the méthodology to run the test without any middleware...
thanks
RogerUse test tool (transaction WE19) for inbound IDOC test.
-
Seeburger EDI Text to EDI XML conversion failure should throw an error
Hi,
I am expecting an error message to be thrown when EDI Text to EDI XML conversion fails at Message splitter of Seeburger module. I am getting the following error in the log.
"2012-01-19T01:46:08.032-0800 ERROR [Error:ID=2150;LEVEL=3] counter value (41) of incoming field (UNB.UNH.UNT:0074) doesnt match the calculated value (39).
DESCRIPTION: Either the counter value is not filled in the source file or the counter field value is wrong. "
But my expectation is that the channel should show some error in Adapter Engine monitoring itself. As shown below, it is just showing some warning that because of above error, it is not creating the attachment. Now I am expecting the the following warning to be an error rather than just warning. Please let me know if any idea on the same.
19.01.2012 01:46:08 Information SEEBURGER/MESSAGESPLITTER: Trying to establish CCI Connection to Message Splitter Adapter
19.01.2012 01:46:08 Information SEEBURGER/MESSAGESPLITTER: Creating CCI Interaction
19.01.2012 01:46:08 Warning SEEBURGER/MESSAGESPLITTER: There is no attachment to split. So there is nothing to do.
19.01.2012 01:46:08 Information SEEBURGER/MESSAGESPLITTER: Finished splitting!
BR,
AmanThanks you all for your inputs..
I got the solution for the same.
I need to set the mapping program name specifically rather than AUTO for bic mappingName parameter. This has turned my communication channel status in RWB into Red for errors.
Closing this thread ...
Regards,
Aman -
Any EDI scenario example?
Hi,
Im in need of a edi scenario example, like a how-to guide.
Any end to end scenario with EDI adapter like step by step is highly appreciated.
Please help.Hi
Available 3rd Party Adapters and Adapter Modules for SAP NetWeaver PI 7.1 provided by SAP via Reseller Agreement
As in the past, SAP continues to rely also for SAP NetWeaver PI 7.1 on partners to provide connectivity solutions for other applications and certain industry standards. With regards to adapters and adapter modules SAP has currently reseller agreements with the companies Informatica, iWay, and SEEBURGER. The connectivity solutions that are covered by the reseller agreements are sold and delivered through SAP, and also technical support for these partner solutions is available via the SAP Support Portal.
SEEBURGER
From the company SEEBURGER all adapters that are covered by the reseller agreement between SAP and SEEBURGER are already certified for SAP NetWeaver PI 7.1; to be more specific, the following SEEBURGER adapters for SAP NetWeaver PI 7.1 that are covered by the reseller agreement are available:
Technical EDI Adapters
AS2 (EDIINT/HTTP(S))
OFTP (OFTP / ISDN, OFTP / TCPIP)
VAN Access (P7 / X.400, VAN FTP)
Business EDI Adapters
Generic EDI
Protocol converter for OFTP / ISDN or VAN Access
Data format converter for ANSI X12, EDIFACT
Mapping templates for purchase order, invoice etc.
Payment
Protocol converter for OFTP / ISDN, VAN Access
Data format converter for EDIFACT, SWIFT
Mapping templates for payment orders, debit advice etc.
Industry specific EDI Adapters
Aerospace & Defense
Automotive
Chemicals
Consumer Products
High-Tech
Paper
Pharmaceutical
Retail
SAP NetWeaver Process Integration 7.1: Available Adapters and Adapter Modules
Handling EDI interfaces using Seeburger BIC modules
Handling EDI interfaces using Seeburger BIC modules
Regards
sandeep -
SEEBURGER AS2 and EDI adapters, PGP Avalanche adapter
Hi,
Kindly anybody can provide the information/links/documentation/PDFs on SEEBURGER AS2 and EDI adapters, PGP Avalanche adapter.
Thanks in advance,
Jogula RameshWhen u install SeeburgerBIC mapper on ur machine, the below location will contain all the required manuals..
C:\Program Files\Seeburger\CPG EDI Adapter\manuals
You can seach SDN weblogs for Seeburger Adapter details if u don't have the software..
Below is the starting Seeburger Adapter Series weblogs..
/people/prateek.srivastava3/blog/2009/08/01/seeburger--part-1--the-basics
-SM -
JMS adapter receiver - converion to text without any end-of-line character
Hi everybody,
We have the scenario
RFC -> PI7.11 -> JMS (MQ Series)
I want to convert the XML document of PI into a text format.
In destination MQSeries, we can't have any end-of-line separator because the destination of MQS target is a Mainframe .
How can we suppress this character End-of-line ?
Can anybody help me top solve this issue, please ?
Thank you for you help in advance.
Kind Regards
E. KoralewskiI solved my issue
I used the module AF_Modules\StrictXml2PlainBean
and I put the parameter field.endSeparator without any value.
Kind Regards -
Turn off suddenly without any warning when plugin Adapter(Charger)
My Pavillion dv6-3208tx turn off suddenly without any warning when plugin Adapter(Charger) and it won't start unless i unpluged the adapter. I can run on battery. Pliz help...!
Make sure the keyboard is seated properly.
(Instructions can be downloaded here.)
Sometimes, plugging in the adapter when the keyboard is improperly seated can cause this behavior. -
Alert Content for text without any XML tag
Hi All,
For the XML workflow,
Need a alert content or select content for the text without any xml tag.
Please help for my XML job request.
Regards
SirajHi All,
New to XML, just learning stage only.
Already I asked and got the coding through forum. It alert text frame ID only.
But, guide me how to get the
1. alert or select the contents.
2. alert the page number or select text frame etc.
Coding is below:
#target InDesign
#include "/Applications/Adobe InDesign CS6/Scripts/Xml Rules/glue code.jsx"
main();
exit();
function main() {
var myDoc = app.activeDocument;
var myStories = myDoc.stories.everyItem().getElements();
var idArray = new Array(0);
var storyArray = new Array(0);
// store all stories of the document in an array
for(var j=0; j < myStories.length; j++) {
storyArray.push(myStories[j].id);
// *** here start the XML-Rules ******************************//
var elements = myDoc.xmlElements;
var myRuleSet = new Array(
alleObj = new all(idArray)
__processRuleSet(elements.item(0), myRuleSet);
// *** here stop the XML-Rules *******************************//
for (var i=0; i < idArray.length; i++) {
for (var k=0; k < storyArray.length; k++) {
if (idArray[i] == storyArray[k]) {
storyArray[k] = -1;
for (var i=0; i < storyArray.length; i++) {
if (storyArray[i] > 0) {
alert(storyArray[i]);
} // if …
} // for()
} // main()
// XML-Rule
function all(idArray) {
this.name = "all";
this.xpath = "//*";
this.apply = function(myElement, myRuleProcessor) {
var storyId = myElement.parentStory.id;
var i=0, found = false;
while ((i < idArray.length) && (!found)) {
if (idArray[i++] == storyId) found=true;
// store anly the number of the stories which are not stored up to now
if (!found) idArray.push(storyId);
return true;
} // this.apply
} // all()
Regards
Siraj -
How can I connetct internet on my ipad mini (non cellular) without wifi ? is there any wifi adapter available ?
You can not connect to the internet with a WiFi only iPad without WiFi. You can get a mobile hot spot from your carrier but that still connects to the iPad via WiFi and comes with a monthly data plan like a cell phone.
-
I have router Sagemcom FASTv7, support wi-fi hot-spot, but not have wi-fi
adapter. Can i make with virtualization or with something else, wi-fi adapter for this CPU?you cannot use wifi with virtualization u have to use local ethernet to access virtualization.
Akshay Pate
I don't understand your. I mean that my router may gave wi-fi to other, but it haven't to get wi-fi from other ..... In now days on noutbooks with only wi-fi(get wi-fi), i use command to create share wi-fi, if driver of the virtual wi-fi
in device manager driver teesting on microsoft soft(digital vertification......) . Can i may use this plan to my sittuation with stationare computer without any wi-fi platform, but having share wi-fi with router those connect to my cpu
thru ethernet? -
Reg: How to Stop Polling of JDBC Adapter without Scheduling the adapter
Dear Gurus,
Here I am having one requirement. My clients wants to send data from JDBC adapter (ORcale System table) to R3 system via RFC.
His Requirement::
1. He is not telling the time of data flow from Oracle server so that based on that we can schedule the adapter in the Communication Channel monitoring (Availablitiy Time Planning) or Else we can Schedule by deciding the setting of the polling interval time.
2. He is telling that When ever he waants to send the data he will place one dummy file in the File Adapter FTP location so that it will became an Indication for u to poll the jdbc adapter and to transfer the data to R3.
3. Untill he keeps the file or gives indication he doesn;t want to communicate with Oracle server due to some security and it s a most important data base he doesn't want to disturb that Oracle Server as so many business are running on that.....
We Proposed::
1. Atleast you need to tell the scheduling time or poll interval time so that we can schedule our adapter.
but he s not accepting for this
2. Atleast U need to give access for Data base to enter one more extra field like STATUS CODE so that we will add one number and we keep on Update in the Update table and based on that Update table statement it will poll.
but he s not even accepting for this
3. Finally we prposed that to create another table in the Oracle SYstem as Dulplicate Table which is similar to Standard Orginal table when ever he wants to pick the data please keep that data in this Duplicate TABle so that JDBC adapter will pick the data from thsi TABLE instead of picking the data from that standard table so that it will not effect any standard table data in the table.
but he s not even accepting for this
We have done some R & D:::
1. WE approached even through BPM and via switch conditions is one scenario
FILE RECEIVE >SWITCH CONDITION> RECEIVE AND SEND or else EXIT
2. Using correlation in anotehr scenario means correlating File adapter and JDBC and based on one dynamica value it will goes to SEND STEP ( RECE IVE --> RECEIVE --> SEND STEPS )
Even though we know this...concept that...we jsut tried::
In BPM we can control the flow in XI 3.0 but we cannot Stop the Polling of JDBC adapter at backend because one the data comes from FILE adapter it will keep on HOLD untill it receives the JDBC from Oracle then based on the condition or Correlation it will goes futher SEND step means after that file adapter is picking file or not ...what ever it may be JDBC will polls at backend and brings that data to BPM"
Hence sugest me How to Stop Polling of JDBC Adapter without Scheduling the adapter or else using STATUS CODE Update statements in JDBC Tables
Regards:
Amar Srinivas EliHi! All,
Finally I decided to do the scenario in two steps:
1: FILE REQ --> JDBC REQ -->JDBC RES --> FILE RECV
2: FILE RECV --> RFC
But I am getting issue while doing first scenario
Desgn :
I have created 2 Synchronous interfaces :
1) FILE 2 JDBC REQ
In this a) out put message is FILE Req
b) Input msage:; FILE RES
2} JDBC2FILE RECV
a) Output mesage;; JDBC REQ
b) Input Msge :: JDBC Response
Mappings:
1) File REQ-->JDBC REQ
2) JDBC RES-->FILE RES
Interface mappings:
1: FILE 2 JDBC REQ--> JDBC 2 FLE RECV
CONFIGURATION ::
1: One Seder File CC
2: Two reciever CC's one is for JDBC RECEIVER and other s FILE RECEIVER
3; One Sender Agreement
4: 2 Recver agreements
5: One Interface Determination and
6: One RECCV Determination
My Question;;
1. First let confirm whether my development steps are right or not ?
2: Another thing s I am not sure reg Configuration Steps means
whetehr one interface determination and one Receiver Determinations are required or not as these are synchronous Interfaces
3: main Issue is::::
If my scenario s FILE2RFC2FILE then I will get RFC response automatically but here issue is this is JDBC
My reqquirement is By sending one Field from fILE to JDBC REQ it needs to send entire TAbLE records as a Response to file as XML
without having Sender JDBC how can I send the JDBC Res to FILE and If that is the case then again JDBC adapter is polling which is contradict to the client requuirement which i explained above.
pleas suggest me the Detailed steps mainly Colloboration agreements and logical routings and
also explain in detail if i can go for BPM
Also give cleear blogs but before giving make sure that it contains detailed screen shots because aIready gone thorugh
Scenario File-JDBC-RFC
File<-->JDBC Sync coomunication.
https://www.sdn.sap.com/irj/scn/wiki?path=/display/xi/file-rfc-file(Without+BPM)
/people/luis.melgar/blog/2008/05/13/synchronous-soap-to-jdbc--end-to-end-walkthrough
Regards::
Amar Srinivas Eli -
FCC configuration in Sender File Channel Without any key field name
Hi Everyone,
We have below flat file generated from ECC using standard tcode.
The flat file is fixed length file and first record is header record followed by line items.
There is no key field name in the file name.
Can we read the file and convert into xml without any key field name?
I want to understand if the FCC configuration for above file can be done without key name or not.
Thanks,
VertikaHello,
AFAIK, using FCC i really doubt u can convert file into xml.
So technically, there are two options either read each line one by one and then do conversions in ur mapping or write a custom module which will read ur input file and convert into xml.
Configuring Generic Sender File CC Adapter
Thanks
Amit Srivastava -
Issue in FF v 3.6.10: I have a web page which have more than 20 link, clicking on each of these link opens up a pop-up using window.showModalDialog, for the first consecutive 20 popup opens up without any prob but for the 21st n more click it block the popup and do not open. This is m problem, the real user on the web page can click on more than 20 link in such a scenario it may create problem, please help
Your above posted system details show outdated plugin(s) with known security and stability risks.
*Shockwave Flash 9.0 r999
Update the [[Managing the Flash plugin|Flash]] plugin to the latest version.
*http://www.adobe.com/software/flash/about/
In Firefox 3.6 and later versions you need the Next-Generation Java™ Plug-In present in Java 6 U10 and later (Linux: libnpjp2.so; Windows: npjp2.dll).
http://java.com/en/download/faq/firefox_newplugin.xml
See also http://java.sun.com/javase/6/webnotes/install/jre/manual-plugin-install-linux.html -
I have an Apple MacBook Pro with 2 USB ports and a MiniDisplay Port. I also have an HDTV with a HDMI port. How can I use the TV as a display without any tethering wires between my computer and the TV? I have a MiniDisplay Port to VGA adapter, but there are two issues with it: The new display doesn't have a VGA port, and even if it did, I wouldn't want to have my mac constantly attached to the display by a cable. I was looking for a way to use the TV as a display without any wires. Is there some type of bluetooth setup I could use? Please let me know if you have any suggestions.
As I wrote above, I think you should look into the Apple TV yourself. The best place to find information about what it can and can't do and to ask your own specific questions is probably in the Apple TV forum, here:
https://discussions.apple.com/community/appletv/appletv -
Creating XML Publisher report without xml data source
Hi
Anyone developed XML publisher without xml source.I wanted to know is there any way to develop that..
Presently we need a .xml file to develop any report on XML Publisher.But if there will be a way where is no .xml file and we need to generate tags for the data from scratch
thanks
kpSo why develop a report if there is no data? I can only think that you have a bunch of static text, maybe an instruction page you want to publish? If so, you still need a data source, it can be a dummy source
<?xml version="1.0"?>
<ROOT/>
ie no data per se. BIP needs a source even if there is not data to merge.
Cheers
Tim
Maybe you are looking for
-
Itunes freezes at the end of podcasts
Not everyone, but if i have 10-20 to watch, itunes will lock up 3-4 times. it's only at the end of the podcast, sometimes after a few mins it will just carry on, mostly it just locks up and i have to end task it. i'm using win7 64bit
-
I lost my ipod. Found it using "find my iphone" but had already "locked" it remotely. THe instructions I read indicate d I'd receive an email from Find My Iphone App with the unlock code...I never received this message/code. THe screen message say
-
Batch date change problem in iPhoto
I have hundreds of printed photos I scanned in 2009. Even though they were taken over three decades iPhoto thinks they were all taken in 2009. I separated them into years, numbered them, and put them in folders which became events. I tried using batc
-
Western Digital Passport 320 GB on macbook
Does anyone have any experience in using a Western Digital Passport _320 GB_ model as an external HD with an intel macbook? Do you power it with 1 or both usb ports? Had any problems with it? Would you recommend? Thanks, .B.
-
Hi, This may be a config issue but I'm trying to help our Business Analyst sort out a problem. He has created a new Notification type Q7 and in config has set Screen Type Hdr = H500, Screen Type Object = 0100 (Functional Location + equipment +assemb