XServe G5 RAID Problem

I have an XServe G5 that has the three slots on the front for the hard drives. It has 2- 80GB hard drives installed. I booted it up off of the install CD and ran a megaraid -destroyconfig and then a megaraid -create R1 -Drive 0 1
It created the RAID fine and then I copied the OS back onto it which boots up and runs fine. The status of the drives through the megaraid are Good and the RAID status is optimal. My problem is when I go into the Server Monitor application under the hard drive it shows one hard drive (drive 1) and says it is a Megaraid but under the Pre-Failure Warning it says not available and there is no green light lit up for the hard drive icon. I am running OS X Server 10.3.9

This is normal.
Since you're running a hardware RAID card, the system can't actually see the physical drives at all.
All it sees is the RAID volumes presented by the RAID card - it doesn't know whether there's one, two or ten drives behind that, or whether they're mirrored, striped, parity, etc., etc.
Therefore it cannot collect the SMART data (the basis of the pre-failure warnings) and it doesn't know if the physical drives are OK or not (the hardware RAID card masks all that data from the OS).
As a result you need to use the megaraid utility to manage the physical drives' status.

Similar Messages

  • Xserve / internal RAID card / Battery Failed (code 0x#0 = 18)

    Hi, RAID utility is reporting a battery problem. I have rebooted xserve once, the problem went away, the battery was charged but now I have the problem again.
    The result is a disabled write cache, which reduces performance.
    Changing the battery is quite a big effort, so I really would like to avoid this. Any ideas, what the problem might be and how to solve it?

    Hi Lordlobby,
    I've had this on 2, 2008 xserves. Started off randomly happening that the RAID card would report the same error code which wasn't down to the discharge cycle. It became worse so the battery was replaced and it's been fine since... It's about 15mins work to replace the battery..
    Good luck
    Beatle

  • SATA RAID problem on K8N Neo2 Platinum (nForce3 ultra) & winXP x64

    I entered on MSI driver dowload page, put my model, and i found out that the RAID driver for win x64 wasn't released (nforce3 ultra), but in the same page was the driver for the nforce4, so I supposed it was compatible. I made the driver disk. press F6 and he askme for the drivers, ok, i introduce BOTH drivers, he detects perefctly the SATA RAID (stripping) format the disk, copy the files and ask me for some .CATof teh raid driver that wasn't on the zip file.... omit files, reboots, completes the instalation, but on the first boot of win x64 when it's just about to show the windows screen, a bue windows, and resets the pc so fast that's unreadable.  fail safe start.. same crash.
    I Installed win on an IDE and it run prefectly... In th other hand... without installing any driver the windows instalation recognices the SATA drives, but not the RAID. Maybe I just got to install the raid driver but not the SATA driver... the nforce3 driver form nvidia.com is pretty old... The real funny is that when i installed winXp x64 BETA i hadn' any problem... (winXP 64 doesn't admit the 32 bit driver=
    Which driver i'm supposed to install? to INSTALL winxp64 on a SATA RAID and make it boot from there?
    Thaks a lot             

    HI! i'm the one wih the raid problem on a k8n neo2....
    That's what a i Did.. i unpacked the exe and copy the files in a floppy... question is: if i do that, windows instaler askme for some files that aren't in the .exe, anway it reconices the raid and everithing goes fine until the first BOOT on windos... it shows a blue screen, butremoves it so fast that i cant read it or pause the system. But i know it's a raid problem because if i install it on a ide disk it works.
    The nforce3 drivers are almost a year old, and i'm not sure if nforce4 is compatible...
    I think the're compatible because if you enter in msi driver download page and select my model, they put the Nforce3 and nforce4 for win64 and my model is only nforce3. The thing is they havent released the nforce3 for WIN 64.... So.. It's normal that win asks me for some files that ain't in the .zip file (i extracted the files o course) and Which driver should i put the Nvidia one year old nforce3 or the new nforce4. (the nforce3 for 32 bits is rejected by windows) or... i have to wait the new nforce3?
    thanks for helps

  • P6N Hardware raid problems (sata 6,7)

    I didn't find the sig things which i find odd but anyway...
    here my rig
    P6n Diamond
    2 asus 8800gts in sli
    i have 4 HDD WD 200 gigs sata2
    (will go into detail about those lovely HDDS)
    dvd burning sata (currently unplug)
    dvd rom IDE plug in
    2 gigs of ram 4x512
    core duo 2.66 ghz
    OK here the problem i wanted 4 HDDS in raid 0 or raid 1 or the 1+0 since i got 4 ... works GREAT fast machines until something went wrong which blew out my original 4 gigs ram 4x1 gig ram sticks and no matter what ram i put in it did not work...sent it in for RMA got it back ever since i got it back RAID BEEN ACTING UP!!! my raid would FAIL in 1+0(i assume it means stripeing and mirroring) and 0 my desktop would hang for a few moments doing gaming regular uses email internet music video uses OR IDLEING after it recovers i get a balloon saying that access fail er to X.X.M drive it use to be one drive now when one acts up the other three follows it examples that was in raid 0 and 1+0 same issues once in a blue moon wait that everyday when i have it in raid 1+0 i found a brand new harddrive in my computer the raid had degraded ? what that means well i know what but HOW ? how did it degraded? so i rebuild the array and geese what compleat fail er it dies and i loose all my stuff on it...now be for someone comes in such as MSI saying that my HDD may be at fault it not...infact it is currently in raid 0 just 2 of them on my other desktop working great and the BEST PART it is FASTER on the P6N i get 200MB burst and when it was in raid 0 i get like 120 continuous read and in raid 1+0 i believe half that speed or 90mbs in the older desktop i get 330mb BURST and i forgot what i got for continuous ready again probably 90 and it is stable plus i ran forever hour es test on the HDD surface scans errors and such and it in 100% good shape and ready to rock....so you guys know the HDDS were in sata 1-4 sata 5 was my dvd burner and 6-7 blank....so i was using the SOFTWARE raid and it not doing so well at all i did try using 2 drives i didn't do a proper test yet but i think it also failed...so seeing that I'm having allot of software raid problems decided to get from bad to worse i cant get anywhere with it so here the new set up now...
    2 hdds ONLY and PHYSICALY installed since the other 2 are in the other computer i have an IDE dvd rom plug  and drive 1 and 4 are plug into the sata 6 and 7 the black and red sata heads...NO BLUE LIGHTS AT ALL NEVER SEEN A BLUE LIGHT... as we know Jp1 and JP2 i think ? there are 4 pins there are 4 possible ways to set that up i tryed all four and no blue lights not even a blink i look close I CANT FIND THE LIGHT PHYSICALLY INSTALLED or i dint recognize it ( i hope i am being blind) what i mean there four ways i tryed jumping one pin from jp1 to jp2 instead of two pins on jp1 and i even put 2 jumpers on both jp1 and 2 and both jumpers the other way from jp1 pin two jp2 pin actually that 6 ways my bad no blue lights...
    the BIOS is set to IDE didn't work in raid as i read from other places if things go well light come on and the BIOS sees it as a single drive which means no floppy to installed 3rd party drives AWESOME!!! cant get it working :( .. it not detecting it at all it saying i have NO HDDS installed at all
    i sent the board in for a second rma..guess what they did they pulled it out and put it in a box and send it right back to me....the moment it got there i get an email saying it being shiped back and i was like oh nice they replace it...they didn't TOUCH it...so I'm calling them up the next day...to find out why they did that and to try to set up the SIL raid....
    now what I'm asking is in case MSI don't help how you guys get yours to work or tell me how to get it working ....and if the HARDWARE raid is a pain then why is my raid failing too much in software raid dose anyone know how to keep the raid alive in software ? i originally wanted software so it supports 4 drives but it failing so I'm dropping it to two drives in the hardware raid and i cant get it to even w/e it is it need to do....any thing will help right now I'm stump i went to this forum spent all day looking through it and tryed some stuff no luck :(
    I'm using an ASUS board on my older desktop for 2 years straight more or less it still in raid 0 NO ERRORS it is sata1 that the HDD only maxi um speed with 2 sata1 in raid 0 it acts like 1 sata2 drive and i never had to reinstalled my OS for 2 years and it gets better the ORGINAL motherboard for that old desktop was an MSI and right now that original board is on my self causes a lil device fryed ( don't think it msi fault but got fed up with that board with allot of bugs it was a NEO F or something really old lol....
    awesome a spell checker :D

    i dont know how two memory stick whould make a diffrent but to answer your question no i havent the goal is to have all 4 sticks and yes they work great i put them in my old system as well and was able to see incrase of performance even though it two gigs all my other hardwares are working find cause when the mainboard was sent in for repaires i move some parts over so i can play SOME games while i wait...now for the power supply it has MORE then enough power it is a 1200 watt thermaltake with 4 12v rails 2 are 20 amps and the other 2 or 36 amps.. 5v rail is 30 or more but the 12 v rail are acurate i was studding it so i can properly connect the 36 amp to my video cards all power cord are plug in like i said all hardwares are working fine causes they were tested befor and none of them were at faults..
    however i will try the memtest86 now dose it need to have an OS installed (dont have it causes it wont see my HDDS in sata 6 and 7) i have to head out in a bit but when i come back ill check it out causes the orginal rams were working find and everythign was happy untill the motherboard blew out and took out 4 ram sticks so i brought a new one from a diffrent brand wich fell into the compatible list of ram for this board the other one was not "comptiable" thank you be back shortly...
    i forgot to mention befor i whould like a good list of directions beside the one in my manuel of how to set up the sata 6 and 7 raid if wores come to wores im going to back up my old HDDS wich have been working great and move it over to the HARDWARE raid and see if it works i will post what i find out but in the mean time the proper set up of the raid hardware will be nice in case i did something wrong thank you

  • NEO4 Plat Sli SIL3231 Raid problem - Can't boot after BIOS Flash!

    Hi, I have and Neo4 Platinum SLI. I had "the problem" a while back with the nVida raid where there was a hang on shutdown. I then created a RAID0 using my two Rators on the SIL3132 controller, and have three hitachi drives hooked up to SATA1 - SATA3. Back then, I had trouble getting my SIL3132 array to be the main boot volume. I could boot when no other drives were attached, but as soon as I attached them, I get the boot disk error after post. Somehow I got it to work, but not think this time, I flashed the BIOS and ran into the same problems, as the BIOS got reset.
    First, I went in and re-enabled RAID on the sil3132 controller, and change the boot order to have the RAID voluime be the first boot device, and my other drivers be the next on down the line. Upon rebooting, my system hangs after verifying DMI pool at a blanksscreen for 5 - 10 minutes then gives my the "missing HAL.dll error". if I go back into the BIOS and disable SATA1/SATA2 and SATA3/SATA4 my computer boots just fine. I even completley disconnected my three drives an my system boots just fine. I have searched these forums and could not find anything close to my issue and wondered if it is something I am just missing in the setup. I will say that at POST my IDE devices has always read:
    IDE Primary Master [None]
    IDE Secondary Master [None]
    IDE Primary Slave (my first DVD/R drive)
    IDE Secondary Slave (My second DVD/R drive)
    IDE Third Master (a 250gb drive)
    IDE Fourth Master (a 250gb drive)
    IDE Fifth Master (a 250gb drive)
    IDE Sixth Master [None]
    Is this normal? all my hard drives are SATA. the raptors and three SATAII drives.
    Any help would be greatly appreciated. Since the Nvida raid problem seems to have been fixed (as far as I read) I would like to go back to using the nVidia raid controller. I just need to back up my system first!
    Thanks in advance.

    Jkmet,
    I have noted the same problem, with a USB Pen drive.
    If I leave it plugged in and shut down, the next time I cold boot it tries to boot for the pen drive.  What I found out the any time you add a drive before booting the BIOS places it at the top of the Hard Drive Priority list making it the boot drive.  Same thing happens when I plug in a new SATA and does not mater where it is connected.  So, what I have to do any time you add a drive with the power off you have to boot to BIOS reset the Hard drive priority list, then save, exit and reboot to boot from you windows drive.
    I am sure this is a BIOS Bug, but MSI states that the way it should would work.
    Roger
    When submitting a problem, include a complete list of your system components; include part numbers, all Power Supply Voltages, and their output ratings.  It is almost impossible to estimate what your problem is without knowing something about it. Here is the link to the web site.

  • K9A2 CF cold boot and RAID problem

    Hi,
    I am struggling with my mobo regarding recent cold boot issues and the problem to set up RAID on the SB600 chipset.
    Here's my rig's description:
    MSI K9A2 CF rev 2 (I believe because of the red heatsink) with the latest available bios flashed using the forum's tool.
    Phenom 9850 BE (stock, never OCed) cooled down with Asetek closed-circuit watercooling.
    2x Radeon 4850 1 Gb crossfire
    4 Gigs of RAM (Nandya Technology)
    HDD WD velociraptor 150 go, WD black caviar 640 go, 2x WD 1 To green caviar all drives are SATA-2
    1 PCI SiI 3512 sata controller for the sata ODD drives (DVD + DVD burner)
    PSU is advent 750 W
    OS: Vista 64 bits home premium working with AHCI drivers
    So here is the deal: the system has been running fine for about a year.
    I recently bought two 1 To HDD to set up a RAID 1 for backup purpose. The goal is to run the velociraptor as system disk (which it is currently) in raid 0+1 jobd (say standalone), the WD 640 go as data disk raid 0+1 jobd (say standalone) and the two 1To as raid one array from the SB600 onboard controller.
    So I flashed the bios to make sure I would have the latest raid rom. The flash was performed with the forum's flasher without a problem, followed by a load defaults and a clear CMOS to be on the safe side.
    Since then, I have random cold boot problems. I fire it up, all leds and drives are on, but no post and nothing on screen, not to mention no beeps whatsoever. I already checked the connections, mobo condensators... everything looks ok. The system was bought pre-built and was working flawlessly beforehand. I need to power it off manually and restart it once to a few times and then it post and boots to the OS without a problem.
    Is there any specific option I should look for in the bios to change that? I assume I might have made a wrong configuration at some point.
    Concerning the RAID problem I cannot access the SB600 onboard Fastbuild utility as long as the PCI sata controller is plugged in --> I get the "Not enough space to load PCI rom" error message. Without the PCI card I can access Fastbuild and define arrays without a glitch. But if I disconnect the card, I no longer have optical drives 
    Does anyone have a clue how to use the SB600 in raid mode along with a PCI sata controller?
    Also, when RAID is setup, arrays defined and all HDDs recognized by the bios, is there a way to make Vista load the raid driver without reinstalling from scratch? For now I can use SATA drives in AHCI mode but get a BSOD whenever I try booting from RAID. 
    I know that's a lot of questions but I could really use some help. I have been roaming the web and could not find anything.
    Thanks in advance for your insight.
    Cheers

    Quote
    Concerning the RAID problem I cannot access the SB600 onboard Fastbuild utility as long as the PCI sata controller is plugged in --> I get the "Not enough space to load PCI rom" error message. Without the PCI card I can access Fastbuild and define arrays without a glitch.
    This is common problem with boot-roms, the BIOS can't handle multiple of them, only 1 if you use raid.
    So disable the PCI-Sata bootrom or disable the RAID.
    This is a BIOS limitation, nothing you can do about it.
    AHCI is a type of RAID also.
    What you see is normal, the BIOS doesn't have enough hooks to put a Boot-rom in, and exspecially the RAID MUST need one to function.
    Other solution is to use Windows software raid and put the RAID controller in normal-mode.
    You won't notice the speed difference anyway as the onboard is a soft-raid as well, but then done in the BIOS, however in both cases it's the CPU that must handle them.

  • Raid problem on Neo2 Platinum

    Have just bougtht a Neo2 Platinum.
    Have also bought 2 x WD 80 Gb SATA HD, because I want to run Raid 0
    In the bios I enable Raid on both chanel 1, 2, 3 and 4 and in the Bios it detects the hd. But when I leave the bios and push F10 to go into the Raid configurations it detects the drivers, but freezes up and I can do nothing. It shovs Mirrored in the menu, and the 2 hd in the "add" colum.
    Any input would be appriciatet.
    Thanks!!

    HI! i'm the one wih the raid problem on a k8n neo2....
    That's what a i Did.. i unpacked the exe and copy the files in a floppy... question is: if i do that, windows instaler askme for some files that aren't in the .exe, anway it reconices the raid and everithing goes fine until the first BOOT on windos... it shows a blue screen, butremoves it so fast that i cant read it or pause the system. But i know it's a raid problem because if i install it on a ide disk it works.
    The nforce3 drivers are almost a year old, and i'm not sure if nforce4 is compatible...
    I think the're compatible because if you enter in msi driver download page and select my model, they put the Nforce3 and nforce4 for win64 and my model is only nforce3. The thing is they havent released the nforce3 for WIN 64.... So.. It's normal that win asks me for some files that ain't in the .zip file (i extracted the files o course) and Which driver should i put the Nvidia one year old nforce3 or the new nforce4. (the nforce3 for 32 bits is rejected by windows) or... i have to wait the new nforce3?
    thanks for helps

  • Copying between XServer RAIDs problem

    I have two XServer RAIDs connected through a fiber switch to an XServe G4 1.33GHz running 10.4.3.
    When I try and copy a folder of about 3,000 files (1.27TB) from one RAID to the other, I get a few hundred of the files and then the drives disappear from the desktop and the copy fails. I have to restart the XServe to get the drives to show back up. Any ideas?

    The switch is a Vixel Emulex 355 12-port. The ports are not disappearing. The only thing I have to do is restart the server to get the RAIDs to show backup. I have tried restarting the RAIDs and the switch, but it seems to be a problem with the XServe. Wonder if the Fiber Card in the XServe could be having a problem? That is a LSILogic LSI7202P Firmware 0.0.0, Fcode 1.00.29.

  • Capturing Video To Xserve Raid problems

    I recently purchased an Xserve raid (1.75TB with 512mb cache on each controller), set it up for Raid 5. I also have an Apple Fibre Card on Slot 4 (the fasted PCI-X slot on my dual 2.0 G5. Much to my surprise when capturing DV video, not HD or DVCPRO, simply DV video via FireWire 400 to the Xserve Raid it can't keep up and drops frames! When I caputure DV video via FireWire 400 to my internal 150gb SATA drive all is well.
    I do have journaling turned on for the Raid, but that can't be the problem.
    Any help would be greatly appreciated.
    thanks

    Hi there,
    I’ve been reading numerous posts by you on the Apple Discussions pages and was wondering if you could help me.
    I work for a small video company with 1 G5 Quad, 4 Dual G5’s and a G5 Imac. We have always worked across a gigabit network, sharing media and projects from each other’s internal and external drives without any problems. However, it was very hard to keep track of what everyone was doing and it was often hard to find specific files.
    Therefore, we decided that it would be a good idea to centralise all of our storage, so we invested in an Apple Xserve Raid, which we connected to one of the dual processor G5’s (which we installed 10.4 server software on) via fibre channel. We figured that we would all be able to access the raid (just like we access each others internal and external drives) and read the media across the network. However, this has not gone to plan!
    I followed the instructions about how to initialise and setup the raid and striped one bank of 7 as Raid 0 (set as our Projects drive) and the other bank as Raid 5 (set as our capture scratch). It does work ok for the most part. The G5 that hosts it works perfectly and most of the time one or maybe two of the other G5’s work well, but on the whole we are dropping a lot of frames and images are freezing frequently.
    My understanding is that all 6 of our edit suites should be able to read DV across the gigabit network and as I have said, this has been the case before we got the raid – which leads me to think there is something, not right with the Raid. I could be here all day if I were to explain all the network settings on each computer, as well as what settings the Raid is set to – and to be honest I wouldn’t even know where to look!
    I don’t know if I made this clear, but we capture locally and move the footage across – the project files and render files are also saved on the raid! We are not trying to work from the same project files, just the same media – but not all the time!
    I really need to understand why we are having so much trouble and any help would be greatly appreciated?
    Kind Regards
    Adam

  • What's the best place to start troubleshooting my Xserve RAID problem

    Hello all,
    I have an older 2.5tb (ide drives) Xserve RAID connected to an HP workstation, which is a video editing sytem. The fiber card connecting the raid is an LSI 7202XP PCI-x card.
    I'm using Windows XP Pro. Nothing on the hardware or software side has been updated or changed in years.
    Recently, I'll be editing video and the Xserve RAID will just "disappear". A computer restart will usually restore it.
    Where's a good place to start troubleshooting? I was going to replace the fiber cables, then the fiber card...then I don't know what.
    I'm just an end user/video editor, so any maintenance help is appreciated!
    Thanks,
    Jason Kalinoski
    Tallahassee, FL

    Normally, it should take less than an hour @ $90 USD for labor to replace one. The HD cost is additional. Why do you think the HD needs replacing? Too small?.Then I suggest an ext FWHD, w/FW800 connector, rather than replacing the int one. If there are issues with the HD, check out the iMac HD replacement program. You should really know when you bought the machine and, IMO, it should have the AppleCare Protection Plan, which is the cheapest insurance policy for desktop machines.

  • MDS9000 (DS-C9124) and Apple XServe/RAID problem.

    Hi all.
    Im new at this so be gentle plz. :)
    We want to connect some servers and raid with fiber channel-network. So we bought this switch to do the job.
    When we connect all together nothing works. Im getting this error: sfpVendorNotSupported
    I cant figure out why it doesnt work. If i connect the server with raid it works flawlessly.
    Any help apreciated.
    thx
    p

    I have seen that error before and it is generally associated with non Cisco "certified" SFP's. You would get that message when you hovered over the port with the mouse. HP sold us some switches and tried putting in some Brocade SFP's because they had some in stock. Once they put the right ones it, is worked.
    There are only a handful of vendor SFP's around for servers and storage and you should not try to use them in the Cisco switches.
    Where did your SFP's come from? If they came with the switch, thats another story.
    Stephen

  • Best option for initial setup of HD's on Xserve (possible RAID)

    I'm just about to set up a new network in a new office and have an Xserve with 3 HD's 2x700GB and 1x500GB drive.
    Now i have a fair bit of experience with the server itself, however i have zero experience with RAID.
    I would like to start automatic backups of the OS (which i do already in a round about way). And have several share points for users network homes and data.
    Does anyone have any suggestions of how to setup the HD's themselves, should i RAID? what would be the best option? etc etc etc.
    All suggestions are very welcome and appreciated.
    Thanks
    Steven

    No one can answer your question - at least not without more information.
    When deciding disk layout you need to factor things like how much usable disk space you need - in this case for users' data. Are the users home directories on the server, or do they just upload files to the server for storage/backup?
    What's the intensity of the data? Is reliability or performance more important? Would you pull your hair out if you lost a single file? a day's work? a week's work?
    How much downtime could you tolerate if the server crashed?
    These questions (and probably more) are important because it helps focus on the needs. For example, if the integrity of the data is more important than uptime you could mirror the two 700 GB drives for the user data and install the OS on the single 1TB drive. Of course this leaves you (slightly) vulnerable to a problem on the OS disk and you could be offline for hours if that disk failed. However, your user data would be mirrored and likely protected from disk failure.
    On the other hand, if the uptime of the server is more important, you might opt to install the OS on the 700GB mirror, using the 1TB for user data, relying on backups to restore this disk if it fails.
    Or, you might decide to put everything (OS and data) on the 700GB mirror, using the 1TB as the backup destination.
    On the other hand you might determine that you need 1TB of user storage space, in which case you either need to use the 1TB for user data, or you need to stripe the two 700GB drives into a 1.4TB array, but then that array has no redundancy and the loss of a single disk will result in the loss of all data.
    So, as I said, there is no one single answer to your question. You'll need to balance storage capacity and redundancy to find the best match for you.

  • Xserve en0 network problem

    I have an unusual network problem which I need to sort.
    I have Intel and G5 Xserves which don't appear to like each other on the network switch they are both connected to. This is an HP ProCurve 1810G
    If I reboot the Intel Xserve when the G5 box is running the WAN ethernet port (en0) on the former will not work. The LAN en1 port continues to work fine. The Xserve G5 needs to be removed from the switch or shutdown before the Intel Xserve en0 port will work again. If I connect the Xserve G5 to a simple Netgear 1Gbit router which in turn is connected to the 1810G all is fine and dandy but this is not a viable longterm solution. There is also a G5, two G4 towers & a Cisco firewall appliance connected to the 1810G but none of these appear to be causing a problem.
    The Intel Xserve provides NAT/VPN services for the LAN and the Xserve G5 is the mail server so they both must play together nicely on the 1810G switch! The 1810G is connected to an ADVA Etherjack demarcation device which is the portal to a fibre optic leased line.
    Just to confirm there are no IP/DNS clashes with the 2 Xserves and the Intel Xserve still has the problem with LOM disabled.
    Very strange problem I know so any suggestions on how to solve this issue would be appreciated.

    This is normal.
    Since you're running a hardware RAID card, the system can't actually see the physical drives at all.
    All it sees is the RAID volumes presented by the RAID card - it doesn't know whether there's one, two or ten drives behind that, or whether they're mirrored, striped, parity, etc., etc.
    Therefore it cannot collect the SMART data (the basis of the pre-failure warnings) and it doesn't know if the physical drives are OK or not (the hardware RAID card masks all that data from the OS).
    As a result you need to use the megaraid utility to manage the physical drives' status.

  • MSI KT3 ultra aru Western Digital 200GB raid problem

    Hi!
    This is what I've got.
    KT3 Ultra-ARU (MS-6380E)
    AMD 2000+
    256 MB 333mhz RAM (AMD Compatible)
    Seagate ST330630A 30GB (an old drive)
    Maxtor 6L080J4 80GB
    Maxtor DiamondMax Plus9 6Y080L0 80Gb 7200rpm 2Mb UDMA133 Fluid IDE
    Western Digital Caviar WD1800JB 180Gb 7200rpm Special Edition UDMA100 IDE
    Western Digital Caviar WD2000JB 200Gb 7200rpm Special Edition UDMA100 IDE
    Promise 100 IDE-controller
    Creative Geforce MX 440
    Lite-on LTR-40125W
    NEC ND-1300 DVD
    And the configuration:
    IDE1: Seagate (Master)
    IDE2: WD1800BG (Cabel Select)
    IDE3(Raid1): Maxtor 6LO80J4 (Master) and Maxtor 6Y080L0 (Slave) raided as an single drive
    IDE4(Raid2): WD2000JB (Cable Select)
    IDE5(IDE-controller1):
    IDE6(IDE-controller2): NEC ND-1300 (Master) and Lite-on LTR-40125W (Slave)
    And the Software:
    I've updated all the software drivers so I've got the newest and I'm currently runnign Win2k SP3 with almost every patch installed on it.
    And finally the problem:
    When I've hook my WD2000JB to the on-board raid everything seems to be working normaly. The bios finds the drive and makes a new array. Win2k boots up and finds the drive and I can create an partition. But when I've try to format it it the computer starts to freeze for a while and then acts like normal again. The HDD-led blinks as it should during the "normal" time, but when the comp. freezes it stops blinking. The formatation stops at 7% and the HDD-led stops lighting. I don't get an error eventhough it was several hours since it stoped. And the formatation takes like 30min for 1%.
    When I connect the WD2000JB to the IDE3 I can format it and it acts just like normal. I even did a full system test with the System tool found on Western Digitals support site and it didn't find any errors. But when move it to the raid-IDE the errors return. I've get Error reading / writing to disk and when I've did a chkdsk I've got the "Coudn't use Device) so I did a scandisk and it found very very many errors so it completly ereased everything that was on it.
    And when I've run Western Digitals program again i've get an error (Disk error read/writing) error code: 0113.
    Can it be that the Western Disk doesn't work well with Raid? I've haven't heard anything about that, so...
    Best regars,
    Mathias

    You can have a look at my hardware below...
    Chassis: Antec 1080B (300w PSU / 180w COMBINED)
    Mainboard: MSI KT3 Ultra ARU
    CPU: AMD Athlon XP 1800+
    Display: ABIT Siluro GF4 Ti4200 AGP 4X
    DVD/CD-RW Combo: HL-DT-ST RW/DVD GCC-4120B
    Floppy: Panasonic 1.44MB
    HD: Quantum Fireball Plus/AS 30.0GB UDMA 100
    Keyboard: Microsoft Internet Keyboard Pro
    Monitor: KDS Visual Sensations VS-190
    Mouse: Microsoft USB Wheel Mouse Optical
    NICs: 3Com 3C900B / DLink DFE-530TX
    RAM: Micron DDR 266MHz (2x256MB DIMMs)
    Sound: Avance AC'97 Audio
    I've had similar problems where my system becomes very unstable at higher bus speeds. Installing Windows XP simply didn't work very good. However, I have ordered a new PSU today as a solution to this problem. Basically, CPUs and video cards are much more demanding and the more devices you have in your computer the more power you're going to need. I recommend purchasing the Enermax EG465P-VE (FCA) 450W ATX PS. It has a higher amperage rating and will most likely solve your problem.
    Check your PSU and your bus speed settings...

  • MSI 865 PE NEO 2 (MS-6728 v.1) raid problems

    Hello guys,hope somebody can help before i throw everything out of the window.
    Hi had this mobo since 2003.
    p4 2.66  800 fsb
    memory pc 2700  333mhz
    Ati radeon 256 mb
    2 ide hds 120gb each on onboard promise as raid optimized for performance (raid0)
    Everything start about a month ago.
    suddenly Pc dont boot from array.( i think was a power cut)
    after playing a bit around I went to fast build (ctrl -f ) delete the array and with option 1 auto detect the array again.
    Pc booted and everything was fine,then messages like " windows no disk error" start to pop up everytime i boot up again.
    I taught about malaware of some kind and even try to reassign a letter for hds that always appeared as "C".
    then very frustrated I had the "brilliant" idea of using window restore point to restore windows some time before  I had this problem.
    Then no more boot guys the man lost control of the machine.
    i tried to use recovery consolle, when i go "chkdsk" says: disk appear to have 1 or more unrecoverable errrors.
    MAP do  not shows the disks (maybe `cause raid?).
    the funny thing is that on fastbuild (ctrl-f) a bootable array is present and "Functional",but when i do option 1 (array autoset up) says "no available disks".
    I have tried to reinstall Promise pdc20378 driver(cannot find original floppy anymore so i have download driver) to reinstall windows XP(SP2),pressed F6 and then s messages says unexpected error on line bla bla bla.
    It does not allow me to install a fresh copy of xp.
    Do you think is the promise raid controller fault?
    do I need to change/reinstall the driver(maybe i have downloaded the wrong 1).
    There is not very important stuff on hds,just years of downloaded movies and songs,which i would like to keep if poss.
    Any suggestions before I throw this superb mobo of the 2003 and get the new p35 chipset?
    Is the machine finally beat the man?
    I thank you all in advance
    A sleepless man

    Thanks HenryW,
    I have create the dikette and done the test.
    It did not recognize the disks on the onboard promise ata raid.....so i plug them on the normal ide
    I ve done quick scan first and 1 of the disk came up with error 0x73 (defective device ..excessive shock),
    then i ve performed advanced scan on the same disk and gave me a different error code 0x72 defective device ..S.M.A.R.T failure.
    I guess 1 of the disk has gone,unless i can repair it somehow with this utilities,or disks have to be read 2gether on the raid controller..
    Well i ll try to see on hitachi website,any more suggestions please let me know.
    I thank you for the great help you are giving

Maybe you are looking for

  • Calling XML Publisher report(RDF based) From OAF

    Hi All, I have requirement where i need to call one of the custom XML Publisher report from oaf by passing the parameters. and i dnt want this using concurrent program. I have an idea of calling xml publisher report which is Data Template based(XML).

  • Printing of A5 copies (3) on HP LaserJet P1102w is very slow

    Hello! I hope someone can help us. At the office we purchased our HP Laserjet only to print invoices. Several months have passed and we are still unable to make it work properly. Technicians have no clue and the provider of the invoicing program has

  • Is there any other method other than se78 to upload a graphic into SAP R/3?

    Hi,   Is there any other method other than se78 to upload a graphic into SAP R/3? Anita Jeyan

  • Program SMIGR_CREATE_DLL does not exist

    Hellio While doing a Hetergeneous System copy of Solution Manager system (Database Independent) and I am performing the Step to generate DDL. When I execute the SMIGR_CREATE_DLL , I get the message "Program SMIGR_CREATE_DLL does not Exist". Can anyon

  • G3 Hard drive problems

    This is a G3 Dual USB 500mhz iBook running Tiger. The problem started with "localised string not found" in Safari. I thought I'd restart the iBook to see if that helped, but I just got the flashing question mark and no restart. I tried putting in the