Error Code: -310606 - example "shift.lvproj" for Spartan 3E doesn't compile

Hello !
I'm new to Labview so I tried to use a project that I found on the web (trafficlight) and it worked perfectly. But it was a little too complicated, so I took a project that I found in the project explorer Help : Shift.lvproj. I tried to compile the shift.vi but I always have the same error :
LabVIEW FPGA called another software component, and that component returned the following error:
Error Code: -310606
NI-COBS:  Access to an FPGA device address has timed out.
Please verify that the communication cable is plugged securely into your computer and target, and verify that the target has power. If the target has a removable clock, verify that the clock is present and running.
I think the cable and the clock are fine as I could run two other projects of my own.
My configuration : Labview 2011 SP1
NI DE FPGA Board plugged on NI ELVIS II+ (but I don't actually use ELVIS)
Thank you for your help !

This error comes from attempts to download and communicate with the VI on the actual FPGA, not from the compilation aspect. We can take a look and check to see if we can recreate the issue with the shipping example.  Otherwise, you could manually try to right-click on the FPGA bitfile buildspec and tell LabVIEW to recompile the bitfile manually and see if that fixes the problem or not.

Similar Messages

  • Installed new HD on Mid-2009 MBP, installed Mavericks, now getting "error code -50" after being on for a while.

    So I had the stock 320gb drive that came with my machine. It started crashing, so I pre-empted the loss of data and installed a spare Western Digital 500gb Scorpio Blue drive, installed Mavericks, and restored my data. Almost immediately I began having sporadic issues with the machine being unable to write to the disk, giving me "error code -50" after being on for about a day or so. I usually just restart and it will work for another day or so, but this is getting very tedious, and I'm a bit worried it might be straining the machine, since I can only hard restart (holding power button) when this happens. Usually, right after restarting, I repair the disk permissions, and this seems to fix things.
    Is this maybe a bad OS install? Maybe I should back up and try it all again? Or is there a software issue I'm not seeing a solution for anywhere? Most people who are getting the "error code -50" messages seem to be getting them on external drives. Is it just a compatibility issue and I need to seek a new drive?

    Thank you for the tips!
    OGELTHORPE wrote:
    I would check to see if the WD HDD has its own Sudden Motion Sensor.  If so, it may be coming in conflict with the one in the Mac.  If that is the case, I suggest disabling the SMS in the Mac.
    WD5000BEVT does indeed have it's own protection:
    ShockGuard™ - Leading-edge ShockGuard technology combines firmware and hardware advancements to protect the drive mechanics and platter surface to meet the highest combined shock tolerance specifications required for mobile and notebook applications.
    Source: http://www.wdc.com/en/company/pressroom/releases/?release=3cd471a1-66be-46ba-9f6 7-e15298b0f8a0
    Even though I read about it I had not touched any SMS settings in OS X since I did not have any problems before. I disabled SMS in Mac, let's see now.
    Melophage wrote:
    this could be indicative of a faulty internal SATA cable. /.../
    Reteep,
    you could try the same thing as well.
    In my case I doubt it is the problem because it worked fine before Mavericks, although forcing restart may have done something. I hope disabling SMS helped.

  • I try to export my Imovie and I always get the error code"Unable to prepare project for publishing...File already open with write permission"  it even does it when I am just trying to export to my external hard drive to save the file

    I try to export my Imovie and I always get the error code"Unable to prepare project for publishing...File already open with write permission"  it even does it when I am just trying to export to my external hard drive to save the file

    Thanks!!! I had same error (with -49) and the mac had an external hard drive attached.. and it was doing a backup.  Stopped, disconnected and the project exported!

  • How can I fix error code 131:4? Licensing for this product stopped working. I have windows vista home edition and CS4 Design Premium. I downloaded licensing zip file for windows but I can't seem to get it to launch. Look forward to help from anyone

    How can I fix error code 131:4? Licensing for this product stopped working. I have windows vista home edition and CS4 Design Premium. I downloaded licensing zip file for windows but I can't seem to get it to launch. Look forward to help from anyone

    Steve,
    I appreciate your answer.  While it might work, I'm a bit hesitant to remove the other programs as a possible solution since they are all currently working.
    With Acrobat 9 Pro failing with the OS 10.7 upgrade, I'm hoping that there is a less severe solution.
    Since the trigger appears to be 10.7 and may have something to do with the discontinued support of Rosetta, I could be spending a few hours working on a reinstall without a change.  Yes, it might work.  The "might" is the part that makes me hesitate.
    Is anyone else out there on OS 10.7 and running Acrobat 9 Pro?  Any issues with anyone else?
    Thanks Steve.  I do appreciate your offering a solution.  I may end up trying it if nothing else comes together.
    Mark

  • Error Code 148:3 - Photoshop CS4 for Windows

    I have a message that comes up whenever I try to open Adobe Photoshop CS4 Extended.
    "Licensing for this product has stopped working.
    This product has encountered a problem which requires that you restart your computer before it can be launched
    If you continue to see this message after restarting your computer, please contact either your IT administrator or Adobe technical support for help, and mention the error code shown at the bottom of this screen.
    Error 148:3
    http://www.adobe.com/support"
    I restarted several times but I still get the error. How do I fix this?

    wow...wssparky  thanks a TON. I got the adobe error today and it was driving me INSANE. I *think* the problem had to do with my having to disable all my startup stuff in Windows7 to fix a problem I was having updating some other Microsoft software. Anyway MS said  disable everything using the msconfig and it was after that when Adobe stopped functioning (my McAfee is having an issue as well) properly.
    At any rate I got the adobe "fix" and it worked GREAT!
    I was NOT having any luck to begin with by going to the support area at adobe.com (HEY ADOBE PEOPLE>> TAKE NOTE)
    searching "support" for the error code tells me "Your search of Support for error 148:3 did not match any documents." which I find interesting
    so I finally googled the error code and found this thread.
    now a word to those who are less than kind in their posts and make people feel  stupid for asking the question here...I would submit these forums are for us (the users) to help each other (read: be nice to each other) so we can USE the software we OWN.
    I'm frankly disappointed that going to the Adobe "SUPPORT" was fruitless. MY problem was with the CS4 suite: I own the master collection which wasn't exactly cheap....it wold be nice if I, as a customer was able to at least FIND Adobe's OWN error code on their support section.
    again... thanks to wssparky

  • SSPI handshake failed with error code 0x8009030c and Login failed for user''

    I got the following error when tried to connect to local machine in the
    non-domain environment with Windows Authentication by SSMS.
    "SSPI handshake failed with error code 0x8009030c while establishing a connection with integrated security."
    "Login failed for user''. the user is nothing associated with a trusted SQL server connection."
    questions
    1,if I saw the "SSPI handshake failed ", does it means it must used Kerberos but failed? or it is also possible used the NTLM but failed?
    2,Any ideas for this issue?
    Please click the Mark as Answer button if a post solves your problem!

    Hi Michael,
    Firstly, "SSPI Handshake Failed" error happens usually when connection failed between the server and domain controllers or failed Kerberos authentication. For more details about "SSPI Handshake Failed" error, please review this
    FAQ.
    Secondly, regarding to your error message, it could be caused by loopback check. To resolve the issue, please set the DisableLoopbackCheck registry entry to 1 by performing the following steps.
    1.Click Start, click Run, type regedit, and then click OK.
    2.Locate and then click the following registry subkey: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Lsa
    3.Right-click Lsa, point to New, and then click DWORD Value.
    4.Type DisableLoopbackCheck, and then press ENTER.
    5.Right-click DisableLoopbackCheck, and then click Modify.
    6.In the Value data box, type 1, and then click OK.
    7.Exit Registry Editor.
    8.Restart the computer.
    There is a similar blog about your scenario for your reference.
    http://www.bhcblog.com/2009/10/08/fix-for-login-failed-for-user-the-user-is-not-associated-with-a-trusted-sql-server-connection/
    Thanks,
    Lydia Zhang
    If you have any feedback on our support, please click
    here.
    Lydia Zhang
    TechNet Community Support

  • Installation failed error code 15 on my desktop for CC 2014 upgrade

    I am trying to upgrade to the 2014 CC on my desktop and everytime I get the error code (15) and try again. I have restarted, but it's no use. I spoke to the support center for an hour, they couldn't figure it out, and they informed me that Adobe would send me an email to correct this, but the email never came and the problem still persists.

    Ankit -
    I am getting an error code 15, after the application downloads to around 52%, I recieve this error message on all of my 2014 downloads:

  • DSEE 7 error code 12 - Sort Response Control for server side sort

    I am using Sun DSEE 7, My application works fine for small data set (e.g. 1000) and gives me correct sorted result, but same code fails for large data set (e.g. 656000). I find that for large data set, I am getting the error "*javax.naming.OperationNotSupportedException: [LDAP: error code 12 - Sort Response Control];*". I have changed the look-throught-limit, size-limit and time-limit values to unlimited using dsconf utility. I changed db cache size, entry cache size to appropriate values and also i increased all-id-threshold, all-ids-threshold-eq, all-ids-threshold-pres to the max possible value (2147483646) for one index attribute which i am using in my query but still exception is coming. If i change my client code (Java code using JNDI) to use Context.NONCRITICAL for SortControl, the sorted result is coming fine for small data set (access log shows query as indexed) but result is not sorted for large dataset and also i see the query is now unindexed. I am using only one attribute for sorting. Please help me out what configuration i am missing here.

    Exactly. There is no reason to have the LDAP server sort the
    results during the retrieval.
    Query of Query can be used such as:
    <cfldap name="ldapResults" .....> <!--- Do the LDAP
    query first --->
    <cfquery dbtype="query" name="sortedResults">
    SELECT
    FROM
    ldapResults
    ORDER BY
    sprintcompany
    ,sprintpocrole
    ,sn
    </cfquery>
    Then, use the "sortedResults" query for the rest of your
    processing.

  • Error Code 0x116 when recovery install for dv6-3120ew is made - HELP !!

    Hello!!
    I have  a problem with HP DV6-3120ew with Windows 7 Home Premium 64 and ATI ARDEON 5470 HD.
    I decided to preinstalled system to new, so I start recovery procedure.
    1) I formatted disk C:
    2) recovery start unpack files to disk
    3) instalation was start, one reset done
    4) after restart HP INstallation start install drivers
    So right now Blue Screen swhow with code error 0x00000116 and after that sytem restart - loop !!
    all the time restart and blue screen ...
    I start procedure recovery two times and this same happend. 
    I used command line and read that system use ATI drivers 8.741.1.1000.
    If I start system in Safe Mode Windows can't finished installation and ask me for start sytem as normal.
    When I replace atikmpag.sys for vga.sys for standard VGA drivers I receive info that windows can't finished installtion and I have to start installation again.
    When after F8 button I try to use VGA resolution - I see black screen without any errors.  But system still using I think ATI drivers just resolution is VGA.
    So System doesn't work at all.
    Right know I want to replace drivers from ATI to standard VGA, how I can do this ?
    BR
    Zbigi

    Hi @Zbigi ,
    Thank you for visiting the HP Support Forums and Welcome. I have looked into your issue about your HP Pavilion dv6-3120ew Entertainment Notebook and system recovery failing.  Here is a link to the Graphics driver for your system.
    You will have to recover the system with your recovery disks that you created. Here is a link to obtaining recovery discs.
    Hope this helps you out.
    Thanks.
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the bottom to say “Thanks” for helping!

  • 6131 and 6212 jcshell: Error code: 6f00 (No precise diagnosis) for install command

    hi all...
    I am trying to install an emv spec cardlet to the 6131 and 6212 phone, but the both of them are not succeeded. I can install the same in JCOP and JMV Pro cards using the same jcop script. The load command is successfull, but my
    install |TESTEMVCARD |TESTEMVCARDDEBITscript returns
    <= 6F 00                                            
    Status: No precise diagnosiswhat may be the problem.? I don,t have the source of cardlet only the cap file
    Please some one help me to solve this problem....
    Thanks in advance..
    Regards
    Anish

    Thank you safarmer.
    safarmer wrote:
    HI,
    0x6f00 means you have an uncaught exception in the install method. This probably means that the applet is trying to instantiate a key pair or cipher that the card does not support that it expects or requires to work. Without the source code you have no real way of knowing what the cause is. It may be as simple as it is trying to allocate more RAM/EEPROM than is available.
    Cheers,
    ShaneI would like to know from where i get 6131 and 6212 phone's secure element specification (Java card OS version,Cryptography supports, RAM/EEPROM size etc ).?
    Regards
    Anish

  • HT201209 Keep getting error "code redemption is temporarily unavailable" for iTunes gift card

    Help!

    I had the same problem so I decided to try going to website on the back. (DisneyOzMovieandOffers.com). It will take you to a page that says to redeem code, enter the code that is given to you and click enter. It will give you options of where you would like to download it from. Click iTunes and it will give you the correct code to download the movie from iTunes.

  • Loading examples, error code 21

    Every time I try to load the examples, about 20 pop-up boxes come up, all with different file names, with error code 21 : external subroutine required for execution could not be found.  I wrote down a list of all the file names that come up, and a few come up twice.
    WsEpQueryGetHitCount.vi
    WsEpQueryGetTitle.vi
    WsEpQueryGetId.vi
    WsEpQueryGetSummary.vi
    WsEpQueryGetMetadata.vi
    WsEpQueryCheck.vi
    WsEpClose.vi
    WsEpQueryAddTerm.vi
    WsEpQueryOpenGroup.vi
    WsEpQueryCloseGroup.vi
    WsEpOpen.vi
    WsEpQuerySubmit.vi
    WsEpQueryRequestMetadata.vi
    WsEpInstallCheck.vi
    WsEpInstall.vi
    WsPing.vi
    WsLookupOpen.vi
    WsCheck.vi
    WsEpInstallcancel.vi
    WsEpQueryCancel.vi
    WsLoopupGetSize.vi
    WsLookupGetCode.vi
    WsLookupGetText.vi
    WsLookupClose.vi
    WsLookupCancel.vi
    Labview was recently loaded on this labtop, and other than attempting to view the examples hasn't been used.  Can someone please offer some suggestions.

    OK, that helps to narrow it down. It looks like that specific example is related to data acquisition. I know you said that no examples load, but let's concentrate on this for now. First, have you installed DAQmx? I'm not familiar with that example, so I'm assuming that's a DAQmx example - it may be a "traditional DAQ" example. If you haven't installed DAQmx you should install that. Otherwise the example won't find the DAQ VIs. (The list you provided are not DAQ VIs, but without the DAQ VIs you won't be able to run any code.) You can check to see whether you should have "traditional" DAQ or DAQmx using the Measurement and Automation Explorer. Yes, this tool is independent of LabVIEW, but it will tell you what software you have installed. Simply go to one of the sytems where it works, run MAX, and then expand "My System -> Software". You will see a list of software that's installed and you can compare it to what you have installed on your system.
    Now, as far as not being able to open any example: Are you trying to open them from the Example Finder, or from disk via the File->Open menu item? You should be able to at least open the files from disk directly. All examples are in the \National Instruments\LabVIEW 7.1\examples directory. DAQ examples, for instance, should be in the "DAQmx" folder and will probably be in libraries. Can you open the examples direct from disk? Try one of the examples in the "general" folder, as these examples are just LabVIEW code without additional libraries.
    If you're trying to open the examples via the Example Finder you most likely do
    not have some services running. Somewhere along the way NI decided to
    use this convoluted method of using services just to open examples. If some of these services are not running, the Example Finder doesn't work. The list of services that get installed is long, depending on what you've got installed:
    National Instruments Domain Service
    National Instruments PSP Server Locator
    National Instruments Time Synchronization
    National Instruments Variable Engine
    NI Configuration Manager
    NI Service Locator
    nidevldu
    NILM License manager
    nipxirmu
    I believe the only service that the Example Finder is dependent on is the NI Server Location, but you should check the status of all these services (if you have them) and see if they're running. Their startup type should be "Automatic".

  • Goods receipt not possible for delivery 80172554: error code 8

    Hi all,
    I got this error but the description does not helps to understand the issue.
    Goods receipt not possible for delivery 80172554: error code 8
    Message no. M7865
    Diagnosis
    The goods receipt for the delivery cannot be posted.
    The error according to the error code:
    1. The delivery does not exist.
    2. The delivery type is unknown.
    3. The delivery is not goods issue posted.
    4. There are no delivery items.
    5. The receiving plant could not be determined.
    6. The delivery items have already been goods receipt posted or contain zero quantities.
    7. Goods receipt(effect)movement type to goods issue movement type could not be determined.
    8. It is not currently possible to block the delivery.
    Procedure
    Error code 1      : Check your entry.
    Error code 2,3,4,6: Check the delivery and its document flow.
    Error code 5      : The delivery must be related to a purchase order or
                        the customer must be a retail business.
    Error code 7      : Check the settins for your movement types.
    CD

    Please check this answered link:
    Re: MIGO
    Re: Inter comapny  PO-
    Goods receipt not possible for delivery 800015869: error code 1
    STO Problem while doing GR against outbound delivery
    Edited by: Afshad Irani on Jun 2, 2010 7:13 PM

  • Goods receipt not possible for delivery 800015869: error code 1

    Dear friends,
    I am doing MIGO-GR for outbound delivery, but getting error once inputting outbound delivery no.
    Goods receipt not possible for delivery 800015869: error code 1
    Message no. M7865
    Diagnosis
    The goods receipt for the delivery cannot be posted.
    The error according to the error code:
    1. The delivery does not exist.
    2. The delivery type is unknown.
    3. The delivery is not goods issue posted.
    4. There are no delivery items.
    5. The receiving plant could not be determined.
    6. The delivery items have already been goods receipt posted or contain zero quantities.
    7. Goods receipt(effect)movement type to goods issue movement type could not be determined.
    8. It is not currently possible to block the delivery.
    Procedure
    Error code 1      : Check your entry.
    Error code 2,3,4,6: Check the delivery and its document flow.
    Error code 5      : The delivery must be related to a purchase order or
                        the customer must be a retail business.
    Error code 7      : Check the settins for your movement types.
    Any poniters to check the setting in PO or delivery or any setting in SPRO.
    Regards
    Ashutosh

    Hi Anupam,
    That is the requirement of my scenario
    That is happening in intercompany posting.
    I am explaining to you.
    say total stock for article AR is 1000 ( In DC --A it is 500 and in store B it is 500)
    I have two company codes X and Y
    One DC (A) belongs to X and second store (B) belongs to Y.
    I have stock available for say article ( am working here in IS Retail  instead of material ) in both DC --A and Store --B.
    Now I have created PO thru replenishment planning WRP1 , now in PO supplying plant is DC.
    Now I did delivery thru VL10B and then picking and then PGI.
    Now my stock is reduced in DC by PO quantity created.( let us assume it is 100)
    So now total stock in DC=400
    Now this stock is in transit we can check thru MB5T. so total stock in transit = 100
    Now I have to do GR against delivery , if I will do GR for 100 nos , there will be no stock in transit
    and stock of receivibg store (B) will increase by 100 nos.
    But I am not able to do GR against delivery so I did GR against PO for say 50 nos. In this case stock in store is increase by 50 nos.
    But there is another stock in transit available=50
    Now why GR is not happening against delivery but it is happening against PO???
    Any pointers

  • Need descriptions for data quality error codes

    I'm getting the following address error codes and I don't have the corresponding messages: F440, F441, F505. I have the descriptions for all the other codes.
    Thanks,
    Nathan

    Nathan,
    Can you tell me which data quality product you are using? If this is for International Address Correction & Encoding you can find all error codes in the Quick Reference for Views and Job-File
    Products. A copy should be installed with your software. Otherwise you may locate a copy at http://help.sap.com/ > Business Objects > Data Quality > Quick Reference for Views and Job-File
    Products
    F440 - Insufficient input data; cannot choose between multiple street-level matches.
    F441 - Insufficient input data; street level match occurred using partial-range matching.
    F505 - Matched to undeliverable default record. The generated undeliverable (F505) has no ZIP+4 listed, an invalid CART, and is flagged as undeliverable.(United States)
    Regards,
    Bob Minard
    Engineer, Technical Customer Assurance