How to capture data at exit command in module pool
hello all,
i have a scenario,on screen i enter some data and i press the cancel button a popup should be displayed saying do you want to cancel.if i press on yes then leave to screen 0.but if i press no then the previous data entered should be displayed on the same screen.
can some body help me on this.
Thanks,
Mayank.....
Hi,
Create a button with type 'E' and
call a POP UP FM 'POPUP_TO_CONFIRM' and write the code to return to the place where you want to.
All the you need to write at at exit command.
The code is like this:
REPORT ztest_at_exit.
DATA:
var1(10),
var2(10),
var3(10).
CALL SCREEN 100.
*& Module STATUS_0100 OUTPUT
text
MODULE status_0100 OUTPUT.
SET PF-STATUS 'ZTEST_AT_EXIT'.
SET TITLEBAR 'ZTEST_AT_EXIT'.
ENDMODULE. " STATUS_0100 OUTPUT
*& Module USER_COMMAND_0100 INPUT
text
MODULE user_command_0100 INPUT.
DATA:
w_ucomm LIKE sy-ucomm.
w_ucomm = sy-ucomm.
CASE w_ucomm.
WHEN 'BACK'.
LEAVE TO SCREEN 0.
WHEN 'EXIT'.
LEAVE TO SCREEN 0.
WHEN 'CANCEL'.
LEAVE TO SCREEN 0.
WHEN 'ADD'.
var3 = var1 + var2.
ENDCASE.
ENDMODULE. " USER_COMMAND_0100 INPUT
*& Module EXIT_100 INPUT
text
MODULE exit_100 INPUT.
DATA:
answer.
w_ucomm = sy-ucomm.
CASE w_ucomm.
WHEN 'EXIT2'.
CALL FUNCTION 'POPUP_TO_CONFIRM'
EXPORTING
text_question = 'Do you want to save this ?'
IMPORTING
answer = answer.
exception
text_not_found = 1
OTHERS = 2.
IF sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
IF NOT answer EQ '1'.
LEAVE TO SCREEN 0.
ENDIF.
ENDIF.
ENDCASE.
ENDMODULE. " EXIT_100 INPUT
Regards,
Rama Chary.P.
Similar Messages
-
How to capture date and userdi in the alert mail
Hi,
In the alert mail I want to capture the userid, date and time. In the container I can define these variables but I was unable to caputre the values. Iam not using any BPM scenario. Can any body help me in this regard how to capture these values. Thanks in advance.
Thanks & Regards,
Mallikarjun.MHi,
Iam using the correct dict type as you mentioned in the above mail. But in my mail it shows that the container elements ZDATE of type SWFXST_DATE, ZTIME of type SWFXST_TIME as not found. I hope this will be solved.
Thanks,
Mallikarjun.M -
How to capture data of text area
Hello Experts,
I have added a text area to a home page using the tag as below
<textarea id="recipient_list" rows="5" cols="40" name="recipients"></textarea>
I expect this text area to be populated at runtime. I want to use the data entered in this text area in one of the methods. But I do not know how to capture the data.
Could you please help me by telling me the way that will make this data available for use in a method of implementation class?
Regards,
PraffulHello Prafful,
In general, you need to connect your text area with a context. So, you need to create a value context node with an attribute which will store the entered text. Then, you need to link you text area with this attribute.
Best Regards,
Yevgen -
Hi, I would like to ask about how to capture data from real time loop.
Hi,
Here is some overvier of my project:
I have done real time control using labview 9.0. I used PID controller.
In order to optimise this controller, I need to capture data from my sensor(input) and actuator (output).
1. For example while real time control is running. I need to capture 1000 sample data (sensor(input) and actuator (output)).
Then I will used these data for PID optimisation on the other loop without intefere my real time loop.
2. When PID optimisation is completed, I will sent its PID parameter to real time control loop.
3. These operation is done in parallel.
Anybody can help me to solve these. Your idea may solve my problem.
TQTypically you will have to use RT FIFO or Queue communication to avoid any impact to your time critical loop.
Best regards
Christian -
How to set user command in module pool program
hello expert,
like in report: PARAMETERS: RB_SING RADIOBUTTON GROUP RAD3 DEFAULT 'X' USER-COMMAND C1.
in module pool program, hw to set user-command in screen.
srinivasPBO.
Call subscreen <SUBSCREEN NAME> Including sy-repid(PROGRAM NAME) G_DYNNR(SCREEN NUMBER'.
PAI
module user_command.
Call subscreen <subscreen name>
Module user_command.
case sy-ucomm.
when 'BUT1'.
g_dynnr = 200.
when 'BUT2'.
g_dynnr = 300.
Endcase.
end module
REPORT demo_dynpro_tabstrip_server.
CONTROLS mytabstrip TYPE TABSTRIP.
DATA: ok_code TYPE sy-ucomm,
save_ok TYPE sy-ucomm.
DATA number TYPE sy-dynnr.
mytabstrip-activetab = 'PUSH2'.
number = '0120'.
CALL SCREEN 100.
MODULE status_0100 OUTPUT.
SET PF-STATUS 'SCREEN_100'.
ENDMODULE.
MODULE cancel INPUT.
LEAVE PROGRAM.
ENDMODULE.
MODULE user_command INPUT.
save_ok = ok_code.
CLEAR ok_code.
IF save_ok = 'OK'.
MESSAGE i888(sabapdocu) WITH 'MYTABSTRIP-ACTIVETAB ='
mytabstrip-activetab.
ELSE.
mytabstrip-activetab = save_ok.
CASE save_ok.
WHEN 'PUSH1'.
number = '0110'.
WHEN 'PUSH2'.
number = '0120'.
WHEN 'PUSH3'.
number = '0130'.
ENDCASE.
ENDIF.
ENDMODULE.
flow logic of the screen 100
PROCESS BEFORE OUTPUT.
MODULE STATUS_0100.
CALL SUBSCREEN SUB INCLUDING SY-REPID NUMBER.
PROCESS AFTER INPUT.
MODULE CANCEL AT EXIT-COMMAND.
CALL SUBSCREEN SUB.
MODULE USER_COMMAND.
flow logic of the screen 110
PROCESS BEFORE OUTPUT.
PROCESS AFTER INPUT.
flow logic of the screen 120
PROCESS BEFORE OUTPUT.
PROCESS AFTER INPUT.
flow logic of the screen 130
PROCESS BEFORE OUTPUT.
PROCESS AFTER INPUT.
REGARDS
VASU -
How to capture error message from standard function module
Dear friends
when i execute standard function module in finance , i am getting error message , pls check the below screen shot,
how to capture the below error message so that i have display in my webdynpro component
Thanks
VijayaHello Vijaya,
Incase of BAPI's they have a return table parameter T_RETURN. Just read that return table to get the error message.
Incase of normal function modules, there will be exceptions raised for the message used inside the function module. Just read the sy-subrc after the FM and based on the sy-subrc value find the respective exception raised.
May be you can try like this, whenever the message is raised it will be stored in the system variable.
CALL FM.
check for the system variables.
sy-msgid = Message ID of the latest message raised.
sy-msgno = message number of the latest message raised.
sy-msgty = message type of the latest message raised.
sy-msgv1 = variable1 of the latest message raised.
sy-msgv2 = variable2 of the latest message raised.
sy-msgv3 = variable3 of the latest message raised.
sy-msgv4 = variable4 of the latest message raised.
Regards,
TP -
'how to code for table control wizard in module pool program
Hi Gurus,
Please provide me a sample code of table control wizard...
Thanks in advance!!!!
Regards,
KranthiHi Kranti,
check this code... it should be helpful
*& Module pool Z_TABLE_CONTROL_WIZARD_DEMO *
PROGRAM z_table_control_wizard_demo .
DATA: BEGIN OF lt_vbak OCCURS 0,
flag TYPE c,
vbeln TYPE vbeln_va,
netwr TYPE netwr,
kunnr TYPE kunnr,
END OF lt_vbak.
DATA: sfkunnr TYPE kunnr.
*&spwizard: declaration of tablecontrol 'TCONTROL' itself
CONTROLS: tcontrol TYPE TABLEVIEW USING SCREEN 9000.
*&spwizard: lines of tablecontrol 'TCONTROL'
DATA: g_tcontrol_lines LIKE sy-loopc.
DATA: ok_code LIKE sy-ucomm.
*&spwizard: output module for tc 'TCONTROL'. do not change this line!
*&spwizard: update lines for equivalent scrollbar
MODULE tcontrol_change_tc_attr OUTPUT.
DESCRIBE TABLE lt_vbak LINES tcontrol-lines.
ENDMODULE. "TCONTROL_change_tc_attr OUTPUT
*&spwizard: output module for tc 'TCONTROL'. do not change this line!
*&spwizard: get lines of tablecontrol
MODULE tcontrol_get_lines OUTPUT.
g_tcontrol_lines = sy-loopc.
ENDMODULE. "TCONTROL_get_lines OUTPUT
*&spwizard: input module for tc 'TCONTROL'. do not change this line!
*&spwizard: modify table
MODULE tcontrol_modify INPUT.
MODIFY lt_vbak
INDEX tcontrol-current_line.
ENDMODULE. "TCONTROL_modify INPUT
*&spwizard: input modul for tc 'TCONTROL'. do not change this line!
*&spwizard: mark table
MODULE tcontrol_mark INPUT.
DATA: g_tcontrol_wa2 LIKE LINE OF lt_vbak.
IF tcontrol-line_sel_mode = 1.
LOOP AT lt_vbak INTO g_tcontrol_wa2
WHERE flag = 'X'.
g_tcontrol_wa2-flag = ''.
MODIFY lt_vbak
FROM g_tcontrol_wa2
TRANSPORTING flag.
ENDLOOP.
ENDIF.
MODIFY lt_vbak
INDEX tcontrol-current_line
TRANSPORTING flag.
ENDMODULE. "TCONTROL_mark INPUT
*&spwizard: input module for tc 'TCONTROL'. do not change this line!
*&spwizard: process user command
MODULE tcontrol_user_command INPUT.
ok_code = sy-ucomm.
PERFORM user_ok_tc USING 'TCONTROL'
'LT_VBAK'
'FLAG'
CHANGING ok_code.
sy-ucomm = ok_code.
ENDMODULE. "TCONTROL_user_command INPUT
* INCLUDE TABLECONTROL_FORMS *
*& Form USER_OK_TC *
FORM user_ok_tc USING p_tc_name TYPE dynfnam
p_table_name
p_mark_name
CHANGING p_ok LIKE sy-ucomm.
*&SPWIZARD: BEGIN OF LOCAL DATA----------------------------------------*
DATA: l_ok TYPE sy-ucomm,
l_offset TYPE i.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
*&SPWIZARD: Table control specific operations *
*&SPWIZARD: evaluate TC name and operations *
SEARCH p_ok FOR p_tc_name.
IF sy-subrc <> 0.
EXIT.
ENDIF.
l_offset = STRLEN( p_tc_name ) + 1.
l_ok = p_ok+l_offset.
*&SPWIZARD: execute general and TC specific operations *
CASE l_ok.
WHEN 'INSR'. "insert row
PERFORM fcode_insert_row USING p_tc_name
p_table_name.
CLEAR p_ok.
WHEN 'DELE'. "delete row
PERFORM fcode_delete_row USING p_tc_name
p_table_name
p_mark_name.
CLEAR p_ok.
WHEN 'P--' OR "top of list
'P-' OR "previous page
'P+' OR "next page
'P++'. "bottom of list
PERFORM compute_scrolling_in_tc USING p_tc_name
l_ok.
CLEAR p_ok.
* WHEN 'L--'. "total left
* PERFORM FCODE_TOTAL_LEFT USING P_TC_NAME.
* WHEN 'L-'. "column left
* PERFORM FCODE_COLUMN_LEFT USING P_TC_NAME.
* WHEN 'R+'. "column right
* PERFORM FCODE_COLUMN_RIGHT USING P_TC_NAME.
* WHEN 'R++'. "total right
* PERFORM FCODE_TOTAL_RIGHT USING P_TC_NAME.
WHEN 'MARK'. "mark all filled lines
PERFORM fcode_tc_mark_lines USING p_tc_name
p_table_name
p_mark_name .
CLEAR p_ok.
WHEN 'DMRK'. "demark all filled lines
PERFORM fcode_tc_demark_lines USING p_tc_name
p_table_name
p_mark_name .
CLEAR p_ok.
* WHEN 'SASCEND' OR
* 'SDESCEND'. "sort column
* PERFORM FCODE_SORT_TC USING P_TC_NAME
* l_ok.
ENDCASE.
ENDFORM. " USER_OK_TC
*& Form FCODE_INSERT_ROW *
FORM fcode_insert_row
USING p_tc_name TYPE dynfnam
p_table_name .
*&SPWIZARD: BEGIN OF LOCAL DATA----------------------------------------*
DATA l_lines_name LIKE feld-name.
DATA l_selline LIKE sy-stepl.
DATA l_lastline TYPE i.
DATA l_line TYPE i.
DATA l_table_name LIKE feld-name.
FIELD-SYMBOLS <tc> TYPE cxtab_control.
FIELD-SYMBOLS <table> TYPE STANDARD TABLE.
FIELD-SYMBOLS <lines> TYPE i.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
ASSIGN (p_tc_name) TO <tc>.
*&SPWIZARD: get the table, which belongs to the tc *
CONCATENATE p_table_name '[]' INTO l_table_name. "table body
ASSIGN (l_table_name) TO <table>. "not headerline
*&SPWIZARD: get looplines of TableControl *
CONCATENATE 'G_' p_tc_name '_LINES' INTO l_lines_name.
ASSIGN (l_lines_name) TO <lines>.
*&SPWIZARD: get current line *
GET CURSOR LINE l_selline.
IF sy-subrc <> 0. " append line to table
l_selline = <tc>-lines + 1.
*&SPWIZARD: set top line *
IF l_selline > <lines>.
<tc>-top_line = l_selline - <lines> + 1 .
ELSE.
<tc>-top_line = 1.
ENDIF.
ELSE. " insert line into table
l_selline = <tc>-top_line + l_selline - 1.
l_lastline = <tc>-top_line + <lines> - 1.
ENDIF.
*&SPWIZARD: set new cursor line *
l_line = l_selline - <tc>-top_line + 1.
*&SPWIZARD: insert initial line *
INSERT INITIAL LINE INTO <table> INDEX l_selline.
<tc>-lines = <tc>-lines + 1.
*&SPWIZARD: set cursor *
SET CURSOR LINE l_line.
ENDFORM. " FCODE_INSERT_ROW
*& Form FCODE_DELETE_ROW *
FORM fcode_delete_row
USING p_tc_name TYPE dynfnam
p_table_name
p_mark_name .
*&SPWIZARD: BEGIN OF LOCAL DATA----------------------------------------*
DATA l_table_name LIKE feld-name.
FIELD-SYMBOLS <tc> TYPE cxtab_control.
FIELD-SYMBOLS <table> TYPE STANDARD TABLE.
FIELD-SYMBOLS <wa>.
FIELD-SYMBOLS <mark_field>.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
ASSIGN (p_tc_name) TO <tc>.
*&SPWIZARD: get the table, which belongs to the tc *
CONCATENATE p_table_name '[]' INTO l_table_name. "table body
ASSIGN (l_table_name) TO <table>. "not headerline
*&SPWIZARD: delete marked lines *
DESCRIBE TABLE <table> LINES <tc>-lines.
LOOP AT <table> ASSIGNING <wa>.
*&SPWIZARD: access to the component 'FLAG' of the table header *
ASSIGN COMPONENT p_mark_name OF STRUCTURE <wa> TO <mark_field>.
IF <mark_field> = 'X'.
DELETE <table> INDEX syst-tabix.
IF sy-subrc = 0.
<tc>-lines = <tc>-lines - 1.
ENDIF.
ENDIF.
ENDLOOP.
ENDFORM. " FCODE_DELETE_ROW
*& Form COMPUTE_SCROLLING_IN_TC
* text
* -->P_TC_NAME name of tablecontrol
* -->P_OK ok code
FORM compute_scrolling_in_tc USING p_tc_name
p_ok.
*&SPWIZARD: BEGIN OF LOCAL DATA----------------------------------------*
DATA l_tc_new_top_line TYPE i.
DATA l_tc_name LIKE feld-name.
DATA l_tc_lines_name LIKE feld-name.
DATA l_tc_field_name LIKE feld-name.
FIELD-SYMBOLS <tc> TYPE cxtab_control.
FIELD-SYMBOLS <lines> TYPE i.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
ASSIGN (p_tc_name) TO <tc>.
*&SPWIZARD: get looplines of TableControl *
CONCATENATE 'G_' p_tc_name '_LINES' INTO l_tc_lines_name.
ASSIGN (l_tc_lines_name) TO <lines>.
*&SPWIZARD: is no line filled? *
IF <tc>-lines = 0.
*&SPWIZARD: yes, ... *
l_tc_new_top_line = 1.
ELSE.
*&SPWIZARD: no, ... *
CALL FUNCTION 'SCROLLING_IN_TABLE'
EXPORTING
entry_act = <tc>-top_line
entry_from = 1
entry_to = <tc>-lines
last_page_full = 'X'
loops = <lines>
ok_code = p_ok
overlapping = 'X'
IMPORTING
entry_new = l_tc_new_top_line
EXCEPTIONS
* NO_ENTRY_OR_PAGE_ACT = 01
* NO_ENTRY_TO = 02
* NO_OK_CODE_OR_PAGE_GO = 03
OTHERS = 0.
ENDIF.
*&SPWIZARD: get actual tc and column *
GET CURSOR FIELD l_tc_field_name
AREA l_tc_name.
IF syst-subrc = 0.
IF l_tc_name = p_tc_name.
*&SPWIZARD: et actual column *
SET CURSOR FIELD l_tc_field_name LINE 1.
ENDIF.
ENDIF.
*&SPWIZARD: set the new top line *
<tc>-top_line = l_tc_new_top_line.
ENDFORM. " COMPUTE_SCROLLING_IN_TC
*& Form FCODE_TC_MARK_LINES
* marks all TableControl lines
* -->P_TC_NAME name of tablecontrol
FORM fcode_tc_mark_lines USING p_tc_name
p_table_name
p_mark_name.
*&SPWIZARD: EGIN OF LOCAL DATA-----------------------------------------*
DATA l_table_name LIKE feld-name.
FIELD-SYMBOLS <tc> TYPE cxtab_control.
FIELD-SYMBOLS <table> TYPE STANDARD TABLE.
FIELD-SYMBOLS <wa>.
FIELD-SYMBOLS <mark_field>.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
ASSIGN (p_tc_name) TO <tc>.
*&SPWIZARD: get the table, which belongs to the tc *
CONCATENATE p_table_name '[]' INTO l_table_name. "table body
ASSIGN (l_table_name) TO <table>. "not headerline
*&SPWIZARD: mark all filled lines *
LOOP AT <table> ASSIGNING <wa>.
*&SPWIZARD: access to the component 'FLAG' of the table header *
ASSIGN COMPONENT p_mark_name OF STRUCTURE <wa> TO <mark_field>.
<mark_field> = 'X'.
ENDLOOP.
ENDFORM. "fcode_tc_mark_lines
*& Form FCODE_TC_DEMARK_LINES
* demarks all TableControl lines
* -->P_TC_NAME name of tablecontrol
FORM fcode_tc_demark_lines USING p_tc_name
p_table_name
p_mark_name .
*&SPWIZARD: BEGIN OF LOCAL DATA----------------------------------------*
DATA l_table_name LIKE feld-name.
FIELD-SYMBOLS <tc> TYPE cxtab_control.
FIELD-SYMBOLS <table> TYPE STANDARD TABLE.
FIELD-SYMBOLS <wa>.
FIELD-SYMBOLS <mark_field>.
*&SPWIZARD: END OF LOCAL DATA------------------------------------------*
ASSIGN (p_tc_name) TO <tc>.
*&SPWIZARD: get the table, which belongs to the tc *
CONCATENATE p_table_name '[]' INTO l_table_name. "table body
ASSIGN (l_table_name) TO <table>. "not headerline
*&SPWIZARD: demark all filled lines *
LOOP AT <table> ASSIGNING <wa>.
*&SPWIZARD: access to the component 'FLAG' of the table header *
ASSIGN COMPONENT p_mark_name OF STRUCTURE <wa> TO <mark_field>.
<mark_field> = space.
ENDLOOP.
ENDFORM. "fcode_tc_mark_lines
*& Module STATUS_9000 OUTPUT
* text
MODULE status_9000 OUTPUT.
SET PF-STATUS 'S9000'.
SET TITLEBAR 'T9000'.
ENDMODULE. " STATUS_9000 OUTPUT
*& Module USER_COMMAND_9000 INPUT
* text
MODULE user_command_9000 INPUT.
CASE sy-ucomm.
WHEN 'BACK' OR 'EXIT' OR 'CANCEL'.
LEAVE TO SCREEN 0.
WHEN 'DISP'.
SELECT vbeln netwr kunnr INTO CORRESPONDING FIELDS OF TABLE lt_vbak
FROM vbak
WHERE kunnr = sfkunnr.
* LEAVE TO LIST-PROCESSING [AND RETURN TO SCREEN <nnnn>].
* By default, the dialog processor returns to the PBO processing of
* the screen from which the list processor was called. The optional
* addition AND RETURN TO SCREEN allows you to specify a different
* screen in the current screen sequence at whose PBO event you want
* to resume processing.
when 'LIST'.
LEAVE TO LIST-PROCESSING.
WRITE:/ 'Time :', SY-UZEIT.
LOOP AT LT_VBAK.
WRITE:/ LT_VBAK-VBELN,
LT_VBAK-NETWR,
LT_VBAK-KUNNR.
ENDLOOP.
WHEN 'SUBM'.
*& You can call executable programs from other ABAP programs using the
*& following statement:
*& SUBMIT <rep>|(<field>) [AND RETURN] [<options>].
SUBMIT z_submit_report VIA SELECTION-SCREEN AND RETURN.
ENDCASE.
ENDMODULE. " USER_COMMAND_9000 INPUT
TABLE CONTROL WIZARD SE51 CODE
PROCESS BEFORE OUTPUT.
*&spwizard: pbo flow logic for tablecontrol 'TCONTROL'
module TCONTROL_change_tc_attr.
*&spwizard: module TCONTROL_change_col_attr.
loop at LT_VBAK
with control TCONTROL
cursor TCONTROL-current_line.
module TCONTROL_get_lines.
*&spwizard: module TCONTROL_change_field_attr
endloop.
MODULE STATUS_9000.
PROCESS AFTER INPUT.
*&spwizard: pai flow logic for tablecontrol 'TCONTROL'
loop at LT_VBAK.
chain.
field LT_VBAK-VBELN.
field LT_VBAK-NETWR.
field LT_VBAK-KUNNR.
module TCONTROL_modify on chain-request.
endchain.
field LT_VBAK-FLAG
module TCONTROL_mark on request.
endloop.
module TCONTROL_user_command.
*&spwizard: module TCONTROL_change_tc_attr.
*&spwizard: module TCONTROL_change_col_attr.
MODULE USER_COMMAND_9000.
regards
padma -
How to get rid of empty space in module pool screen?
Hello Experts,
In module pool, I have 2 table controls inside 2 separate boxes in the same screen. Based on some conditions I hide the first table control. It's all working fine. But the space where first table is created remains blank in the screen. I don't want that.If the first table control is hidden the second table control should occupy the empty space. I do not want empty space in the screen.
How can I acheive this.Is there anything I can set in the screen attribute level.
Thanks.
Yasin.Hi Yasin,
As you said you have 2 sub screen areas and also 2 subscreens.
when hide the First subscreen from First Subscreen area, you need to assign the second subscreen on to the first subscreen area and a dummy subscreen on to second subscreen area, this is a kind of work around and bit tricky playing with screen elements
in Top Include
data dynnr type sy-dynnr value '100' " your default Subscreen number
in PBO
call subscreen sub1 including sy-repid dynnr1 " First Sub screen area
call subscreen sub2 including sy-repid dynnr2 " Second sub screen area
in PAI
module call_dyn_number.
in program.
case ok_code.
when 'HIDE'. " When you hide the first table control
dynnr1 = '200' " This is your second table control containing Screen number
dynnr2 = '300'. "This is a Dummy Screen Number which doesnt contain any screen elements so output is plain
" Note: This is a crude IDEA only as you try to implement you need to adjust this for the expected outcome
" I implemented this earlier but dont have complete ref at this moment
endcase.
Hope this serves your purpose
Cheerz
Ram -
How to write select options with extension in module pool program
hi,
M having the following fields through screen painter.
1. sales offfice
2.sales district
3.customer no
for those three fields no extension is not provided and no search help is there.
i want write seletion options to get extension in that module pool
screen.
plese send coding for me , please let me know how to get that
select options with the above all three fields.
Thanks & Regards
RajiCheck it
In top include
DATA: number(4) TYPE n VALUE '9005',
PROCESS BEFORE OUTPUT.
MODULE status_9001.
CALL SUBSCREEN AREA1 INCLUDING SY-REPID number.
PROCESS AFTER INPUT.
MODULE user_command_9001.
CALL SUBSCREEN AREA1.
*& Module status_9001 OUTPUT
text
MODULE status_9001 OUTPUT.
SELECTION-SCREEN BEGIN OF SCREEN 9005 AS SUBSCREEN.
PARAMETER pa_bukrs TYPE t001-bukrs.
select-options matnr for wa_matnr.
SELECTION-SCREEN END OF SCREEN 9005.
ENDMODULE. " status_9001 OUTPUT -
How to remove symbol of line selection in module pool
Hello Experts,
I am working on a module pool where I have created a line selection.
In this line selection when we click on the order number I have made a coding where it call new transaction.
But I dont want the default symbol which comes during line selection..the magnifying type symbol.
How can I delete this symbol.
My coding is:
at pbo:
MODULE CALL_STATUS_LIST OUTPUT.
LEAVE TO LIST-PROCESSING AND RETURN TO SCREEN 0.
SET PF-STATUS SPACE.
SUPPRESS DIALOG.
ENDMODULE. " call_status_list OUTPUT
at line-selection.
and than the coding.
Thanks and Regrds,
Nikhil.Hi Keshu,
Not working,
I have used this coding:
DATA: pf_itab TYPE TABLE OF sy-ucomm.
APPEND 'PICK' TO pf_itab.
SET PF-STATUS 'STA3' EXCLUDING pf_itab.
but than again my line selection does not work.
Thanks,
Nikhil. -
Regarding exit from the module pool screen
h experts,
i have developed a module pool report in which in the selection screen i have four fields which are mandatory ,when i execute the program without entering in the selection screen it do not allow to come out of the module pool screen ...what i want that without entering any input in the selection screen if i press exit button push button it will allow to come out of the screen for this what sud i do plz help me....Hi
keep a button called <b>EXIT</b> on the screen
Make the function type of that field as <b>E</b>
in Flow logic write
PROCESS AFTER INPUT.
Forced Exit from the transaction from screen
MODULE exit AT EXIT-COMMAND.
double click on exit module and
then in PAI write
*& Module exit INPUT
Exit from the Transaction
MODULE exit INPUT.
CASE okcode.
WHEN 'EXIT' OR 'CANCEL'.
CLEAR okcode.
LEAVE PROGRAM.
ENDCASE.
ENDMODULE. " exit INPUT
<b>Reward points for useful Answers</b>
Regards
Anji -
Displaying Data Using Selection-screen in Module Pool
Hi All,
Currently I'm working on a module pool program.In that i'm having two screens 9000 and 9001.
I want to select a bookrefno using a selection screen and display header & table control data in 9001 screen when the bookrefno is validated.
can anyone help me sending sample code regarding this
Regards
Ravi SHi Ravi
Place "bookrefno." field on screen 9000.
Use validations on that particular field by using chain-endchain.
in PAI of 9000
case sy-ucomm
when 'display'
call screen 9001
write select statment to display data i.e header & table control in 9001 .
hope this would solve your problem.
reward points, if its helpful.
Thanks
RK Nimma -
How to disable an i/p textbox in module pool
how to disable an i/p textbox in module pool
How is the textbox implemented? ... if it is using a text edit control, you can use something like:
call method go_my_textedit->set_readonly_mode
exporting
readonly_mode = 1.
where go_my_textedit is "type ref to cl_gui_textedit".
Jonathan
p.s. this thread might be better in the UI Programming forum. -
How to attach FCODE to select option in Module Pool
Hi all,
I have created Select option in Module pool by attaching a Subscreen. Now when user enters any value into the select option I need to fetch values from the database in to the table control based on the value entered in select option.
Is it possible and how?
Thanks.<b>Hi
If u have one select options in module pool programming,Then there is no need for FCODE
bcoz FCODE is needed for push button,check box..like etc.
But select option is a input field.
So u can trace the input as u have done in report
Like
select * from dtab1 into corresponding fields of table itab where field1 in <b>selectoption.</b>
Or if u want that program to be executed after giving input in select option then user will press F8
So Use FCODE 'F8'.
Regs
Manas Ranjan Panda
Message was edited by:
MANAS PANDA</b>
Message was edited by:
MANAS PANDA -
How to access screen field value in a module pool programming?
Hi Experts,
I have create a module pool program SAPMYDLG. It contains two screens 100 and 200.
The first screen contains Employee_ID field. This field is not a dictionary field.
In the second screen 200, I want to access the value of Employee_ID field from first screen.
For this I created a global variable v_empid in TOP include.
Then in the PAI of the screen 100 I have assigned the screen field value to global variable.
v_empid = Employee_ID.
But this gives an error saying " Field Employee_ID not defined".
What am I doing wrong? How can I access the screen field value?
Thanks
GopalHi,
Employee_ID field also must u define in the top include when u define that 100 screen and 200 screen will access.
regards,
muralii
Maybe you are looking for
-
My purchases are not showing up.
A bit of background: I had to wipe my hard drive and I don't have my itunes library anymore. When I went to download all my songs again, only 166 of them were shown to have existed and almost all of them were songs that I did not have on my ipod, bu
-
I am using iphone 4S with sprint carrier with IOS 7 and has error 1394
I am using iphone 4S with sprint carrier. It has IOS 7 and now I want to downgrade to IOS 6 and I have downloaded a firmware it is compatible with 4S. Now it shows error 1394 and I have tried to fix my host file in windows according to other forums i
-
My screen flash in photo booth is not working..any help here?
Even though that the screen flash is enable but everytime I try to use it...it's the same..i mean no flash effect at all. Any help guys?
-
Problem installing RAM (flashing power light, etc.)
Hi everyone. I have been spending the last 2 hours trying to install this OCX Ram (2x1GB) into my PowerMac G5 Dual 2.5. Before installation, I just had the 2x512 Apple memory. After installing the RAM following instructions from Apple's website, I tu
-
How can I get FF to print my crossword in greyscale?
I belong to The Times crossword website. when a crossword is accessed there are two buttons on the page: print in black, print in grey. If you click on print in grey the crossword turns grey, and it appears grey on the page and in print preview. Howe