How to use a select option parameter?
hi
i have created a selection screen in this way
select-option car_no for equi-equnr.
now i want to move all the values that i have selected in car_no range into an itab?
i used the debugger and so that i have low and high i can i move all the values into an itab
thanks.
Hi,
If you want to move the values of your select-options into an internal table, LOOP the select options and move the values into your internal table.
sample code:-
select-options car_no for equi-equnr.
loop at car_no.
wa_itab-equnr = car_no-low.
append wa_itab to itab.
endloop.
But here you have to take care of few things.
Firstly the values which are excluded. There are 4 fields in selection options - Option, sign, Low and High. When sign is 'I' you can move it into your internal table. When it is 'E' you should not select that particular entry.
Secondly, do you have any high values. If there are high values available then you have to take all the values beteween low and high an move them into your internal table. One thing can be done in this case - while declaring the select option you can add "NO INTERVALS " so there would be only low value available unless user goes into EXTENSION option and selects ranges option.
If you wante to move them into ranges internal table, then you can declare ranges and move it into that table.
smaple code:-
DATA: r_equnr TYPE RANGE OF equi-equnr,
wa_r_equnr LIKE LINE OF r_equnr.
r_equnr[] = car_no[]
Can you give more clarification about your requirement, so that a better solution can be provided.
Edited by: Krishna Adabala on Nov 27, 2008 9:50 AM
Similar Messages
-
How to use the select option to get the multiple bom explosion
hi friends,
i have completed the bom exp using parameters to get one material
input,but i need to adopt select option to give from and to materials
i ll gives from and to materials with description and bom deails
i here gave the coding also, pl give me a suggestion how to adpot the select
optoins instead of parameters ,very urgent
REPORT PP_BOM_EXPLOSION.
tables :mara,marc,stpo.
TYPE-POOLS : SLIS.
*parameters: p_werks like t001w-werks obligatory.
SELECT-OPTIONS : p_matnr FOR mara-matnr obligatory.
**select-options : p_matnr for mara-matnr obligatory.
PARAMETERS : P_WERKS LIKE T001W-WERKS OBLIGATORY,
P_MATNR LIKE MARA-MATNR OBLIGATORY.
*parameters: p_werks like marc-werks obligatory,
*p_matnr like marc-matnr obligatory.
constants c_x value 'X'.
data: begin of it_comp occurs 0,
matnr like mara-matnr,
maktl like makt-maktx,
idnrk like stpox-idnrk,
ojtxp like stpox-ojtxp,
menge like stpox-menge,
meins like stpox-meins,
matkl like stpox-matmk,
end of it_comp.
data : topmat like cstmat.
data: w_topmat like cstmat.
DATA : IT_MARA LIKE MARA OCCURS 0 WITH HEADER LINE.
DATA : IT_FIELDCAT TYPE SLIS_T_FIELDCAT_ALV.
DATA : WA_FIELDCAT_LN LIKE LINE OF IT_FIELDCAT.
DATA : IT_EVENTCAT TYPE SLIS_T_EVENT.
DATA : WA_EVENTCAT_LN LIKE LINE OF IT_EVENTCAT.
DATA : IT_LAYOUT TYPE SLIS_LAYOUT_ALV.
DATA: S_COL_POS TYPE I.
start-of-selection.
perform explode_assembly.
PERFORM BUILD_FIELDCATALOG.
PERFORM DATA_DISPLAY.
*end-of-selection.
*perform write_report.
*top-of-page.
*perform print_header.
*form print_header.
*write: /(18) 'Component'(h00),
*(40) 'Description'(h01),
*'Mat.Group'(h02),
*(18) 'Quantity'(h03).
*uline.
*endform.
*form write_report.
*write: / w_topmat-matnr under text-h00 color col_heading,
*w_topmat-maktx under text-h01 color col_heading.
*loop at it_comp.
*write: /
*it_comp-idnrk under text-h00,
*it_comp-ojtxp under text-h01,
*it_comp-matkl under text-h02,
*it_comp-menge unit it_comp-meins under text-h03,
*it_comp-meins.
*endloop.
*uline.
*endform.
form explode_assembly.
data: it_stb like stpox occurs 0 with header line,
it_stb2 like stpox occurs 0 with header line,
it_stb3 like stpox occurs 0 with header line,
w_msg(255) type c.
SELECT MATNR FROM MARA INTO CORRESPONDING FIELDS OF TABLE IT_MARA
WHERE MATNR IN P_MATNR.
Explode highest level:
*LOOP AT IT_MARA.
call function 'CS_BOM_EXPL_MAT_V2'
exporting
auskz = c_x
capid = 'PP01'
cuols = c_x
datuv = sy-datum
knfba = c_x
ksbvo = c_x
mbwls = c_x
mdmps = c_x
BGIXO = c_x
MKMAT = c_x
MMAPS = c_x
FBSTP = c_x
FTREL = c_x
mtnrv = P_MATNR
werks = p_werks
importing
topmat = w_topmat
tables
stb = it_stb
exceptions
alt_not_found = 1
call_invalid = 2
material_not_found = 3
missing_authorization = 4
no_bom_found = 5
no_plant_data = 6
no_suitable_bom_found = 7
conversion_error = 8
others = 9.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4
into w_msg.
*write: / w_msg.
exit.
endif.
Don't process documents
delete it_stb where idnrk is initial.
Don't process valid from furure:
delete it_stb where datuv >= sy-datum.
Explode phantom assemblies up to last level
*do.
it_stb2[] = it_stb[].
*delete it_stb2 where dumps is initial.
*if it_stb2[] is initial.
*exit.
*endif.
*delete it_stb where not dumps is initial.
delete it_stb where VPRSV <> 'S' OR MMSTA = '61'.
loop at it_stb2.
call function 'CS_BOM_EXPL_MAT_V2'
exporting
capid = 'PP01'
auskz = c_x
cuols = c_x
datuv = sy-datum
knfba = c_x
ksbvo = c_x
mbwls = c_x
mdmps = c_x
FBSTP = c_x
FTREL = c_x
mtnrv = it_stb2-idnrk
werks = p_werks
tables
stb = it_stb3
exceptions
alt_not_found = 1
call_invalid = 2
material_not_found = 3
missing_authorization = 4
no_bom_found = 5
no_plant_data = 6
no_suitable_bom_found = 7
conversion_error = 8
others = 9.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4
into w_msg.
*write: / w_msg.
else.
delete it_stb3 where idnrk is initial.
delete it_Stb3 where sobsl = 50.
loop at it_stb3 .
multiply it_stb3-menge by it_stb2-menge.
modify it_stb3 transporting menge.
endloop.
append lines of it_stb3 to it_stb.
endif.
*ENDLOOP.
endloop.
*enddo.
Build table of components collecting the same components from
all levels
loop at it_stb.
it_comp-matkl = it_stb-matmk.
it_comp-idnrk = it_stb-idnrk.
it_comp-ojtxp = it_stb-ojtxp.
it_comp-menge = it_stb-menge.
CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT'
EXPORTING
INPUT = IT_STB-MEINS
LANGUAGE = SY-LANGU
IMPORTING
LONG_TEXT =
OUTPUT = IT_STB-MEINS
SHORT_TEXT =
EXCEPTIONS
UNIT_NOT_FOUND = 1
OTHERS = 2
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
it_comp-meins = it_stb-meins.
collect it_comp.
clear it_comp.
endloop.
*READ TABLE IT_COMP INDEX 1.
*IF SY-SUBRC = 0.
IT_COMP-MATNR = w_topmat-matnr.
IT_COMP-MAKTL = w_topmat-maktx.
INSERT IT_COMP index 1.
*ENDIF.
ENDFORM.
FORM TO APPEND DATA INTO ALV FORM
FORM BUILD_FIELDCATALOG.
PERFORM BUILD_FIELDCAT USING 'MATKL' 'Component'.
PERFORM BUILD_FIELDCAT USING 'MATKL' 'Component'.
*loop at it_comp.
PERFORM BUILD_FIELDCAT USING 'MATNR' 'Material'.
PERFORM BUILD_FIELDCAT USING 'MAKTL' 'Material Description'.
PERFORM BUILD_FIELDCAT USING 'IDNRK' 'Component'.
PERFORM BUILD_FIELDCAT USING 'OJTXP' 'Description'.
PERFORM BUILD_FIELDCAT USING 'MATKL' 'Material Group'.
PERFORM BUILD_FIELDCAT USING 'MENGE' 'Quantity'.
PERFORM BUILD_FIELDCAT USING 'MEINS' 'Unit Of MEASUREMENT'.
*endloop.
ENDFORM.
FORM TO BUILD IN FIELD CATALOG FOR ALV FORM
FORM BUILD_FIELDCAT USING L_FIELDNAME LIKE DD03L-FIELDNAME S_TEXT LIKE DD03P-SCRTEXT_M.
CLEAR WA_FIELDCAT_LN.
ADD 1 TO S_COL_POS.
WA_FIELDCAT_LN-REF_TABNAME = 'IT_COMP'.
WA_FIELDCAT_LN-FIELDNAME = L_FIELDNAME.
WA_FIELDCAT_LN-SELTEXT_M = S_TEXT.
WA_FIELDCAT_LN-COL_POS = S_COL_POS.
WA_FIELDCAT_LN-QFIELDNAME = SPACE.
WA_FIELDCAT_LN-HOTSPOT = SPACE.
WA_FIELDCAT_LN-JUST = 'R'.
APPEND WA_FIELDCAT_LN TO IT_FIELDCAT.
ENDFORM.
FORM TO BUILD IN FIELD CATALOG FOR ALV FORM
FORM DATA_DISPLAY.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
I_CALLBACK_HTML_END_OF_LIST = ' '
I_STRUCTURE_NAME =
I_BACKGROUND_ID = ' '
I_GRID_TITLE = TEXT-001
I_GRID_SETTINGS =
IS_LAYOUT =
IT_FIELDCAT = IT_FIELDCAT
IMPORTING
E_EXIT_CAUSED_BY_CALLER =
ES_EXIT_CAUSED_BY_USER =
TABLES
T_OUTTAB = IT_COMP
EXCEPTIONS
PROGRAM_ERROR = 1
OTHERS = 2
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
endform.
Thanks in advance
Regards
senthilkumar Dtables :mara,marc,stpo.
parameters: p_werks like t001w-werks obligatory.
*p_matnr like mara-matnr obligatory.
*select-options : p_matnr for mara-matnr obligatory.
select-options : P_matnr for mara-matnr.
*parameters: p_werks like marc-werks obligatory,
*p_matnr like marc-matnr obligatory.
constants c_x value 'X'.
data: begin of it_comp occurs 0,
idnrk like stpox-idnrk,
ojtxp like stpox-ojtxp,
menge like stpox-menge,
meins like stpox-meins,
matkl like stpox-matmk,
end of it_comp.
data: w_topmat like cstmat.
data : begin of itab occurs 0,
matnr like mara-matnr,
end of itab.
*data : itab type table of mara with header line.
start-of-selection.
perform explode_assembly.
end-of-selection.
perform write_report.
top-of-page.
perform print_header.
form print_header.
write: /(18) 'Component'(h00),
(40) 'Description'(h01),
'Mat.Group'(h02),
(18) 'Quantity'(h03).
uline.
endform.
form write_report.
write: / w_topmat-matnr under text-h00 color col_heading,
w_topmat-maktx under text-h01 color col_heading.
loop at it_comp.
write: /
it_comp-idnrk under text-h00,
it_comp-ojtxp under text-h01,
it_comp-matkl under text-h02,
it_comp-menge unit it_comp-meins under text-h03,
it_comp-meins.
endloop.
uline.
endform.
form explode_assembly.
data: it_stb like stpox occurs 0 with header line,
it_stb2 like stpox occurs 0 with header line,
it_stb3 like stpox occurs 0 with header line,
w_msg(255) type c.
select matnr from mara into table itab where matnr between p_matnr-low and p_matnr-high.
loop at p_matnr.
itab-matnr = p_matnr-low.
append itab.
itab-matnr = p_matnr-high.
append itab.
clear itab.
endloop.
Explode highest level:
loop at itab.
call function 'CS_BOM_EXPL_MAT_V2'
exporting
auskz = c_x
capid = 'PP01'
cuols = c_x
datuv = sy-datum
knfba = c_x
ksbvo = c_x
mbwls = c_x
mdmps = c_x
BGIXO = c_x
MKMAT = c_x
MMAPS = c_x
FBSTP = c_x
FTREL = c_x
mtnrv = itab-matnr
werks = p_werks
importing
topmat = w_topmat
tables
stb = it_stb
exceptions
alt_not_found = 1
call_invalid = 2
material_not_found = 3
missing_authorization = 4
no_bom_found = 5
no_plant_data = 6
no_suitable_bom_found = 7
conversion_error = 8
others = 9.
if sy-subrc <> 0.
message id sy-msgid type sy-msgty number sy-msgno
with sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4
into w_msg.
write: / w_msg.
exit.
*else.
endif.
loop at it_stb.
it_comp-matkl = it_stb-matmk.
it_comp-idnrk = it_stb-idnrk.
it_comp-ojtxp = it_stb-ojtxp.
it_comp-menge = it_stb-menge.
it_comp-meins = it_stb-meins.
collect it_comp.
clear it_comp.
endloop.
endloop.
endform.
i got the low and high from selectoption and then move it into itab.
then i pass itab-matnr into fm. using loop.
but i got only one output
but ineet to got from and to output.
give me a solution
Regards
ds -
How to use offset for select-option parameter ?
Hi experts
could anybody please let me know how to use offset for select-option parameter. i can able to use offset for table fields, variabiles and all , but don't know how to use for parameters.
following is my code
SELECT-OPTIONS: s_prctr FOR vbsegs-prctr OBLIGATORY.
here "prctr" length is 10.
i'm using two tables 1. vbsegd-bupla
2. vbsegs-prctr
here prctr+6(4) = bupla.
"Bupla" length is 4
SELECT belnr gjahr bukrs bupla sgtxt buzei FROM vbsegd INTO CORRESPONDING FIELDS OF TABLE it_vbsegd FOR ALL ENTRIES IN it_vbkpf
WHERE belnr = it_vbkpf-belnr
AND gjahr = it_vbkpf-gjahr
AND bukrs = it_vbkpf-bukrs
AND bupla IN s_prctr.
the above statement is not working as prctr and bupla lenths are different. here i want to use offset.
SELECT belnr gjahr bukrs prctr sgtxt buzei FROM vbsegs INTO CORRESPONDING FIELDS OF TABLE it_vbsegs FOR ALL ENTRIES IN it_vbkpf
WHERE belnr = it_vbkpf-belnr
AND gjahr = it_vbkpf-gjahr
AND bukrs = it_vbkpf-bukrs
AND prctr IN s_prctr.
this is working as prctr and s_prctr lengths are equal.
could anybody please help me out in this.
Thanks in advance.
regards
satishBelow code will work for you.
SELECT-OPTIONS: s_prctr FOR vbsegs-prctr OBLIGATORY.
RANGES: s_bupla FOR vbsegd-bupla.
s_bupla[] = s_prctr[].
DELETE ADJACENT DUPLICATES FROM s_bupla.
SELECT belnr gjahr bukrs bupla sgtxt buzei FROM vbsegd INTO CORRESPONDING FIELDS OF TABLE it_vbsegd FOR ALL ENTRIES IN it_vbkpf
WHERE belnr = it_vbkpf-belnr
AND gjahr = it_vbkpf-gjahr
AND bukrs = it_vbkpf-bukrs
AND bupla IN s_bupla. -
How to restrict values displayed using a select-options
Can someone please tell me how to restrict values displayed using a select-options.
Example- in my table I have 100 entries. However when the user will click on the required field- I want to be display only 25 options based on a given value of another field in the table.
Thanks,
Mahesh.get the screen value for the selectd field using the fm
DYNP_VALUES_READ.
for that value filter the internal table values and pass the table to f4 help of the field.
below code will help u
write the f4 help for the field.
At Selection Screen on value request *
F4 help for Corporate
AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_CORP.
Get Corporates for selected division
PERFORM GET_CORP.
PERFORM F4HELP_CORP.
*& Form GET_CORP
Get the corporates for the selected division
There are no interface parameters to be passed to this routine
FORM GET_CORP .
Table for conglomerate
DATA:
LT_CONG LIKE STANDARD TABLE OF FS_CORP,
Fields of current screen
LFS_DYNPREAD TYPE DYNPREAD,
Table for current Screen fields
LT_DYNPREAD LIKE STANDARD TABLE OF LFS_DYNPREAD.
LFS_DYNPREAD-FIELDNAME = 'P_DIV'.
APPEND LFS_DYNPREAD TO LT_DYNPREAD.
Get selection screen value for division
CALL FUNCTION 'DYNP_VALUES_READ'
EXPORTING
DYNAME = SY-REPID
DYNUMB = SY-DYNNR
TABLES
DYNPFIELDS = LT_DYNPREAD
EXCEPTIONS
INVALID_ABAPWORKAREA = 1
INVALID_DYNPROFIELD = 2
INVALID_DYNPRONAME = 3
INVALID_DYNPRONUMMER = 4
INVALID_REQUEST = 5
NO_FIELDDESCRIPTION = 6
INVALID_PARAMETER = 7
UNDEFIND_ERROR = 8
DOUBLE_CONVERSION = 9
STEPL_NOT_FOUND = 10
OTHERS = 11.
IF SY-SUBRC EQ 0.
READ TABLE LT_DYNPREAD INTO LFS_DYNPREAD INDEX 1.
IF SY-SUBRC EQ 0.
P_DIV = LFS_DYNPREAD-FIELDVALUE.
ENDIF. " IF SY-SUBRC EQ 0
ENDIF. " IF SY-SUBRC EQ 0
REFRESH T_CORP.
Get the conglomerate for the selected division
SELECT KUNNR " Conglomerate
FROM KNVH
INTO TABLE LT_CONG
WHERE HITYP EQ C_HITYP
AND VKORG EQ C_VKORG
AND VTWEG EQ C_VTWEG
AND SPART EQ P_DIV
AND DATAB LE SY-DATUM
AND DATBI GE SY-DATUM
AND HKUNNR EQ SPACE.
IF SY-SUBRC EQ 0.
SORT LT_CONG BY KUNNR.
DELETE ADJACENT DUPLICATES FROM LT_CONG
COMPARING KUNNR.
Get the corporates for the selected conglomerates
SELECT KUNNR " Customer Number
FROM KNVH
INTO TABLE T_CORP
FOR ALL ENTRIES IN LT_CONG
WHERE HITYP EQ C_HITYP
AND VKORG EQ C_VKORG
AND VTWEG EQ C_VTWEG
AND SPART EQ P_DIV
AND DATAB LE SY-DATUM
AND DATBI GE SY-DATUM
AND HKUNNR EQ LT_CONG-KUNNR.
IF SY-SUBRC NE 0.
CLEAR: SSCRFIELDS.
MESSAGE I531(0U) WITH TEXT-005.
STOP.
ENDIF. " IF SY-SUBRC NE 0
ELSE.
CLEAR: SSCRFIELDS.
MESSAGE I531(0U) WITH TEXT-004.
STOP.
ENDIF. " IF SY-SUBRC EQ 0
ENDFORM. " GET_CORP
*& Form F4HELP_CORP
F4 help for corporate
There are no interface parameters to be passed to this routine
FORM F4HELP_CORP .
F4 help for corporate
CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
EXPORTING
RETFIELD = 'KUNNR'
DYNPPROG = 'Z_EXCESS_USAGE'
DYNPNR = '1000'
DYNPROFIELD = 'P_CORP'
VALUE_ORG = 'S'
TABLES
VALUE_TAB = T_CORP
EXCEPTIONS
PARAMETER_ERROR = 1
NO_VALUES_FOUND = 2
OTHERS = 3.
IF SY-SUBRC EQ 0.
Do nothing
ENDIF. " IF SY-SUBRC EQ 0
ENDFORM. " F4HELP_CORP -
Select-option parameter passed to function module
hi,
I have passed the select-option parameter as a table to my function module,
suppose i have passed it as date(it contains field date-high and date-low)
In my function module while i am looping the table and selecting the data according to date_low,it is going to select only the data according to date_low.
since the table contains only one row.
loop at date.
select the data according to date_low.
date_low = date_low +1.
modify date_low.
endloop.
how can i select all the data from date_low and date_high?Hi,
there is issue design of ur FM .
You have to put 2 table parametrs or 2 import paremeters in the FM ,after that with in the Function module fill the internal table of type ranges (say itab).
After filling the ranges internal table, this can be used in ur select stament just as select option ( select ...where podat in itab)
revrt back if any issues.
regards,
Naveen -
In BI how to filter the selection options based on inputs on top field
Hi Friends,
In BI, How to filter the selection options based on inputs on top field.
The system should automatically filter the lower level drop downs based on the selection of a higher level.
For e.g. :
If a user selects a Country then the States drop down should only display the State's belongs to the Country. Similarly when a State is selected, the District drop down should display only those District's belongs to the State.
Thanks in Advance.
Regards
Jayaram MHi Anil,
Thanks for reply but I couldn't use Compounding Characteristic here. Need some other solution.
Regards
Jayaram M -
How to use multiple selection parameters in the data model
Hi, after have looked all the previous threads about how to use multiple selection parameters , I still have a problem;
I'm using Oracle BI Publisher 10.1.3.3.2 and I'm tried to define more than one multiple selection parameters inside the data template;
Inside a simple SQL queries they work perfectly....but inside the data template I have errors.
My data template is the following (it's very simple...I am just testing how the parameters work):
<dataTemplate name="Test" defaultPackage="bip_departments_2_parameters">
<parameters>
<parameter name="p_dep_2_param" include_in_output="false" datatype="character"/>
<parameter name="p_loc_1_param" include_in_output="false" datatype="character"/>
</parameters>
<dataTrigger name="beforeReport" source="bip_departments_2_parameters.beforeReportTrigger"/>
<dataQuery>
<sqlStatement name="Q2">
<![CDATA[
select deptno, dname,loc
from dept
&p_where_clause
]]>
</sqlStatement>
</dataQuery>
<dataStructure>
<group name="G_DEPT" source="Q2">
<element name="deptno" value="deptno"/>
<element name="dname" value="dname"/>
<element name="loc" value="loc"/>
</group>
</dataStructure>
</dataTemplate>
The 2 parameters are based on these LOV:
1) select distinct dname from dept (p_dep_2_param)
2) select distinct loc from dept (p_loc_1_param)
and both of them have checked the "Multiple selection" and "Can select all" boxes
The package I created, in order to use the lexical refence is:
CREATE OR REPLACE package SCOTT.bip_departments_2_parameters
as
p_dep_2_param varchar2(14);
p_loc_1_param varchar2(20);
p_where_clause varchar2(100);
function beforereporttrigger
return boolean;
end bip_departments_2_parameters;
CREATE OR REPLACE package body SCOTT.bip_departments_2_parameters
as
function beforereporttrigger
return boolean
is
l_return boolean := true;
begin
if (p_dep_2_param is not null) --and (p_loc_1_param is not null)
then
p_where_clause := 'where (dname in (' || replace (p_dep_1_param, '''') || ') and loc in (' || replace (p_loc_1_param, '''') || '))';
else
p_where_clause := 'where 1=1';
end if;
return (l_return);
end beforereporttrigger;
end bip_departments_2_parameters;
As you see, I tried to have only one p_where_clause (with more than one parameter inside)....but it doesn't work...
Using only the first parameter (based on deptno (which is number), the p_where_clause is: p_where_clause := 'where (deptno in (' || replace (p_dep_2_param, '''') || '))';
it works perfectly....
Now I don't know if the problem is the datatype, but I noticed that with a single parameter (deptno is number), the lexical refence (inside the data template) works.....with a varchar parameter it doesn't work....
So my questions are these:
1) how can I define the p_where_clause (inside the package) with a single varchar parameter (for example, the department location name)
2) how can I define the p_where_clause using more than one parameter (for example, the department location name and the department name) not number.
Thanks in advance for any suggestion
AlexAlex,
the missing thing in your example is the fact, that if only one value is selected, the parameter has exact this value like BOSTON. If you choose more than one value, the parameter includes the *'*, so that it looks like *'BOSTON','NEW YORK'*. So you need to check in the package, if there's a *,* in the parameter or not. If yes there's more than one value, if not it's only one value or it's null.
So change your package to (you need to expand your variables)
create or replace package bip_departments_2_parameters
as
p_dep_2_param varchar2(1000);
p_loc_1_param varchar2(1000);
p_where_clause varchar2(1000);
function beforereporttrigger
return boolean;
end bip_departments_2_parameters;
create or replace package body bip_departments_2_parameters
as
function beforereporttrigger
return boolean
is
l_return boolean := true;
begin
p_where_clause := ' ';
if p_dep_2_param is not null then
if instr(p_dep_2_param,',')>0 then
p_where_clause := 'WHERE DNAME in ('||p_dep_2_param||')';
else
p_where_clause := 'WHERE DNAME = '''||p_dep_2_param||'''';
end if;
if p_loc_1_param is not null then
if instr(p_loc_1_param,',')>0 then
p_where_clause := p_where_clause || ' AND LOC IN ('||p_loc_1_param||')';
else
p_where_clause := p_where_clause || ' AND LOC = '''||p_loc_1_param||'''';
end if;
end if;
else
if p_loc_1_param is not null then
if instr(p_loc_1_param,',')>0 then
p_where_clause := p_where_clause || 'WHERE LOC in ('||p_loc_1_param||')';
else
p_where_clause := p_where_clause || 'WHERE LOC = '''||p_loc_1_param||'''';
end if;
end if;
end if;
return (l_return);
end beforereporttrigger;
end bip_departments_2_parameters;
I've written a similar example at http://www.oracle.com/global/de/community/bip/tipps/Dynamische_Queries/index.html ... but it's in german.
Regards
Rainer -
How can i decleare select-options in module pool table control?
Hi everybody!!
Can anyone tell me how can I decleare select-options in module pool table control screen?. I have declared it in a screen with a table control but a dump is triggered due to an error when generating the selection screen.
Regards...My suggestion will be try to use fm
call function 'FREE_SELECTIONS_DIALOG'
Please search this forum you can find lot of threads related to this.
a® -
How to hide the select-options fields on radiobutton select in webdynpro
hi
Could you please help how to hide the select-option fields in webdynpro
there are four radio buttons
for every radiobutton there is corresponding the select_option filed is associated to it
user as only provision select one radio button and reset of the select-option fileds should be hidden
which ever the radio button is selected corresponding the select-options fileld should be displayed
please find the attachement belowHi Nine,
To hide select options you should use interface method REMOVE_SELECTION_SCREEN_ITEM of IF_WD_SELECT_OPTIONS.
Sample code :
Write the below code in the Event handler of Radio Button.
DATA lv_r_helper_class TYPE REF TO if_wd_select_options.
lv_r_helper_class = lo_interfacecontroller->init_selection_screen(
lv_r_helper_Class->REMOVE_SELECTION_SCREEN_ITEM(exporting i_id = 'Select_option1_id1').
This will hide first select option of your screen.Similarly pass select_option_id2 to hide it and so on.
Regards,
Ravikiran.k -
How to use drill down option in Crystal Report
Dear all,
I want to know how to use drill down option in Crystal report 2008. In below i have explained my screnario
For example
My scenario is. In crystal report I have Purchase order like PO101,PO102. Each purchase order have 5 line items. If i drill down each purchase order it should display line item in crystal report.
Regards,
Baskaran.hi,
Create a Group on 'Purchase order'.
Group Expert -> Select the Purchase Order and Click the arrow button such that it appears right side. Click ok.
GH1 is inserted.
Your detail section should include 'Line items' fields.
Right Click 'Detail' section on left hand side, Click 'Hide (Drill down Ok)'.
Now you will see only 'Purchase order's in Group Headers.
Now when you click on a particular order, you will see respective line items.
Regards,
Vamsee -
How to create the select option in the screen
HI,
I am developing one module pool program and I have below requirement,
currently plant is acting like PARAMETER and the now it should be changed to select option.
how to create the select option in the screen
Thanks and regarding,
Malla
Moderator message - Please search before asking - post locked
Edited by: Rob Burbank on Dec 16, 2009 1:41 PMTry RANGES.
The RANGES has same structure as that of select-options. -
Dialog programming - How to place a select-option field in a dialog screen
Hi all,
In Dialog Programming, How to place a select-option field in a dialog screen.
Kindly give me some example code...
Thanks,
Jaffer Ali.Shi Ali,
U can add select-options in ur module pool by using SELECTION-SCREEN BEGIN OF SCREEN <scrn> AS SUBSCREEN command.
check this link for reference.....
http://help.sap.com/saphelp_47x200/helpdata/en/e7/deb237b9a9a968e10000009b38f8cf/frameset.htm
Example Code :
DATA : ok_code TYPE sy-ucomm.
SELECTION-SCREEN BEGIN OF SCREEN 1010 AS SUBSCREEN.
SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-001.
PARAMETERS: p_rad1 RADIOBUTTON GROUP grp1 DEFAULT 'X',
p_rad2 RADIOBUTTON GROUP grp1,
p_rad3 RADIOBUTTON GROUP grp1.
SELECT-OPTIONS: s_matnr FOR mara-matnr,
s_matkl FOR mara-matkl,
s_mtart FOR mara-mtart.
SELECTION-SCREEN END OF BLOCK b1.
SELECTION-SCREEN END OF SCREEN 1010.
START-OF-SELECTION.
CALL SCREEN 100.
*& Module STATUS_0100 OUTPUT
MODULE status_0100 OUTPUT.
SET PF-STATUS 'xxxxxxxx'.
SET TITLEBAR 'xxx'.
CALL SCREEN 1010 .
ENDMODULE. "status_0100 OUTPUT
*& Module USER_COMMAND_0100 INPUT
text
MODULE user_command_0100 INPUT.
CASE ok_code.
WHEN 'EXIT'.
LEAVE PROGRAM.
ENDCASE.
ENDMODULE. " USER_COMMAND_0100 INPUT
SCREEN 100 ****************
PROCESS BEFORE OUTPUT.
MODULE status_0100.
CALL SUBSCREEN sub_1010 INCLUDING sy-repid '1010'.
<b>***** where sub_1010 is name of sub-screen area</b>
PROCESS AFTER INPUT.
CALL SUBSCREEN sub_1010.
MODULE user_command_0100.
<<< REMOVED BY MODERATOR >>>
Harimanjesh AN
Edited by: Marcelo Ramos on Dec 17, 2008 7:54 PM -
How to create the select option for the Plant in screen (Module pool)
HI,
I am developing one module pool program and I have below requirement,
currently plant is acting like PARAMETER and the now it should be changed to select option.
how to create the select option in the screen
Thanks and regarding,
Malla
Moderator message - Cross post locked
Edited by: Rob Burbank on Dec 16, 2009 1:41 PMSteps to get SELECT-OPTIONS in module pool programs.
1.Start one dialog program with SAPMZ_001.
Place the below code in the TOP include of the dialog program.
TABLES marc.
SELECTION-SCREEN BEGIN OF SCREEN 3200 AS SUBSCREEN.
SELECT-OPTIONS: werks FOR marc-werks.
SELECTION-SCREEN END OF SCREEN 3200.
2 .Create one screen 3000.
Go to Layout of the screen and Define subscreen area on the screen and Name it as l_subscreen.
Place the below code in the Flow logic of the screen.
PROCESS BEFORE OUTPUT.
CALL SUBSCREEN l_subscreen INCLUDING 'SAPMZ_001' '3200'.
PROCESS AFTER INPUT.
CALL SUBSCREEN l_subscreen.
Activate all.
Create Transaction code for the dialog program .
Execute the transaction code. You will see the select-option for werks how we see on Selection-screen. -
Passing select option parameter to a procedure
Hello, i need to know pass a select option parameter to a procedure. I tried the following
For eg if i have a select option called so_belnr & i call the procedure using the following
PERFORM VALIDATE_DOCUMENT TABLES SO_BELNR USING GJAHR BUKRS , i still cannot use the
select option paramter in the called procedure.
Pls help.Hi,
in topinclude...
data: lr_belnr type RNG_BELNR.
at start-of-sel.....
move so to range..
refresh: lr_belnr.
lr_belnr[] = so_belnr[].
PERFORM VALIDATE_DOCUMENT TABLES lr_belnr USING GJAHR BUKRS .
in form:
... tables lr_belnr like structure of RNG_BELNR.
reason(my definietion): perfom doesn´t know if the select-options is availible.....
bestreg
Robert -
How to use the print option for photos?
How to use the print option for photos. I have a wireless printer but how do I set it up?
http://www.apple.com/support/iphone/assistant/airprint/
Maybe you are looking for
-
What RAM and SSDs will go in a Mac Mini? ...
Getting ready to snag a new Mac Mini after the announcement tomorrow. Assuming the new ones accept the same RAM and HDs and the existing ones ... What kinds/sizes of RAM go in the Mini? What kind of SSD specs will fit in the Mini? Thanks very much in
-
New songs off of Iphone 5 will not sync onto itunes.
Usually, when I buy new music off my phone and then sync it to my itunes, the songs download onto itunes. But lately it has been coming up with a message saying, "This computer is already associated with and Apple ID." I do share this itunes with my
-
How do I silence an incoming text message alert while I'm in the middle of a telephone conversation?
-
Inner Class included in build.xml
I am trying to get my build.xml to include an inner class that gets created when my web service class is compiled. How do I make this file a part of the final ear file in the build.xml file?? I can add it by hand afterwards but that seems too complic
-
Hello experts, Currently I'm playing with the sap.m.icontabbar. I've placed a simple sap.m.Table (list with products) with a navigation to the product details (sap.m.list) on the first tab. The current behavior is if I tap on a product item a new pag