IP SLA and SNMP monitoring

Hello All,
I want to create a IP SLA so that I can monitor UP time for ISP's as the I Ethernet connectivity, so if there link down beyond the mux, i cannot find that when it went down and at what time it came back, Basically for how long it? So i want to set IP SLA between CE-PE and same i want to plot a graph in MTRG so that NOC team can motinor as well we can pull historical report for that link.
Can you please suggest if this is achievable? if yes than how can i achieve this?
Thanks
Jagdev

Hi ,
 You can configure IP SLA on your device using below link 
http://www.cisco.com/c/en/us/td/docs/ios/12_4/ip_sla/configuration/guide/hsla_c/hsicmp.html
you need to download MIB on to your MRTG server for montioring 
CISCO-IPSLA-ECHO-MIB
CISCO-IPSLA-ETHERNET-MIB
Look into below url for loading MIB 
http://oss.oetiker.ch/mrtg/doc/mrtg-reference.en.html
HTH
Sandy

Similar Messages

  • Configure Cisco Mediatrace, Cisco IOS IP SLA, and Performance Monitoring

    Hi all,
    I am implementing Cisco Prime Collaboration to monitor the quality of the VoIP call.
    I am following all the steps that I have to do to accomplish this task at this link:
    http://docwiki.cisco.com/wiki/Setting_up_Devices_for_Prime_Collaboration_Assurance#Configuring_Unified_Contact_Center_Enterprise_Devices
    And now I am arrived on this step:
    Configure Cisco Mediatrace, Cisco IOS IP SLA, and Performance Monitoring
    Not all the Cisco devices that I have on the network are "Mediatrace, IP SLA and Performance Monitoring" capabilities. The core switch is one of them.
    What will happen if some devices are configured with these capabilities and some are not?
    Are the data provided from Cisco Collaboration still reliable?
    Thanks in advance.
    Luigi

    I can't see a reason why the 2 features won't work together. The 2 features will work just fine with each other.
    Unfortunately there is no sample config with both feature in the same document, but it will work just fine.

  • Recommended product for syslogging and snmp monitoring

    Hi,
        We currently use KIWI syslog but can anyone recommend a better product for syslogs from Firewalls, Routers and Switches. Our current product creates a seperate text file per day per device. Ideally I would like all these to be combined (or combinable for display purposes) into one log that shows to update realtime and have the ability to filterout "background noise" - stuff we know is acceptable, as well as being able to run simple or quick searches and reports. Ideally for asbout 200+ devices.
         Am I too hopeful or is there a product out there that can do this (that also will not break my companies bank account).
         Also, recommended products for SNMP monitoring if better than we currently use would be useful - currently using Orion and SNMPc.
    Regards
    Adrian

    Adrian,
    We use syslog-ng for RHEL. It can do what you need as far as writing to files and filtering out background noise, but it is not a search/reporting tool. If KIWI does the latter, I imagine you could tell it to read from the file that syslog-ng creates.
    It is open source for writing files through version 3.1.4. Later versions require licensing to write to files or if you are using a Windows OS.
    http://www.balabit.com/downloads/files/syslog-ng/open-source-edition/3.1.4
    Here are some other options:
    Rsyslog: http://www.rsyslog.com/
    Splunk: http://www.splunk.com/
    Snare: http://www.intersectalliance.com/projects/index.html
    Hope this helps.
    Steve Lee
    Emory University

  • WLC 5508 and SNMP monitoring

    Dear all,
    I'm a little bit confused about this piece of hardware.
    I wonder if there is possibility of monitoring power supply and fans status (like on the other Cisco devices)?
    This info is usually located in ENV-MIB, but seems to me, there is no support of this MIB. Even temperature of box is located in some weird OID.
    Does anyone know, where to find above mentioned?
    For start, power supply (to see through snmp, something like this via CLI):
    Power Supply 1................................... Present, OK
    Thanks for ideas.
    Pavel

    Hi Pavel:
    Please know that the wireless LAN controllers were developed by Airespace and prior to their acquisition by Cisco in 2005, they had already created their own SNMP MIBs (the OIDs start .1.3.6.1.4.1.14179).  Since the acquisition, several former Airespace objects have been obsoleted and replaced by CISCO-LWAPP-* or other Cisco objects, yet some former Airespace objects remain in use, depending on the software train in use on the wireless LAN controller.  There are wireless MIBs for each software train in the Software Center. 
    All the maintenance releases (i.e. 7.0.240.0, 7.0.230.0, 7.0.220.0, 7.0.172.0, etc.) within a given train (i.e. 7.0.something.something, 6.0.something.something, 5.2.something.something) should have the same objects since maintenance releases are only supposed to contain bug fixes, while trains introduce new features and/or functionality--which, in turn, would require new SNMP objects.
    Try walking agentSwitchInfo (.1.3.6.1.4.1.14179.1.1.3):
    nms-jasmine:~# snmpwalk 172.18.254.29 agentSwitchInfoAIRESPACE-SWITCHING-MIB::agentSwitchInfoLwappTransportMode.0 = INTEGER: layer3(2)AIRESPACE-SWITCHING-MIB::agentSwitchInfoPowerSupply1Present.0 = INTEGER: false(0)AIRESPACE-SWITCHING-MIB::agentSwitchInfoPowerSupply1Operational.0 = INTEGER: false(0)AIRESPACE-SWITCHING-MIB::agentSwitchInfoPowerSupply2Present.0 = INTEGER: false(0)AIRESPACE-SWITCHING-MIB::agentSwitchInfoPowerSupply2Operational.0 = INTEGER: false(0)nms-jasmine:~#

  • ISE distributed environment and snmp monitoring

    - I wonder wether there are any specific MIBS dealing or supporting node statuses in a distributed ISE
    environment , I would like to be able to query the replication status of a node , using a SNMP MIB variable,
    is thos possible ?
    M.

    Not sure because I didn't find any MIB for this purpose. I have also checked in ISE 1.2 and the result was same. you can also check on this link.
    http://www.cisco.com/en/US/docs/security/ise/1.2/user_guide/ise_mib.html

  • SCOM SP1 Groups, Classes and SNMP

    I've been working on a management pack using some of the examples on the net (Kristopher Bash from the operating-quadrantin has been a huge inspiration) to monitor an Isilon cluster.  This had lead me to a number of interesting challenges to over come since I have to design this within the confines of SP1 and I have a unique networking to device configuration. 
    Device Overview:
    The Isilon cluster itself is a number of FreeBSD systems (nodes) joined together via and infiniband backend to create a single NAS.  While normally this would not be an issue, network connectivity to the device and SNMP response from the cluster have been.  In my configuration I have a total of 8 nodes each node has 2 network interfaces.  Of these 16 network interfaces only 2 are accessible/on the same network as my RMS (em1 node2, em1 node4).
    Device SNMP Design:
    While the cluster is highly dynamic the SNMP sub-systems are not.  The MIB created by Isilon does not join the whole of the cluster into an index for SNMP polling.  I can only poll a single nodes OID's.  To over come this limitation Isilon implemented SNMP-Proxy or comtosec within the system.  This allowed me to poll node 3 by changing the community name for the OID I was polling from the discovered name to <discoveredname>_node_3.
    MP Design:
    Now I'm not the best at MP design since I rarely work within SCOM so don't laugh too hard...  I reused items from Kristopher's Cisco MP and created a number of classes for discovery and item hosting.  To address the limitation I found within SCOM for dynamic discovery and 1 IP address 1 Community Name, I created a class property within the root called ConfiguredNodes.  I can poll the Isilon an populate this value (8).  Then I created a sub-class property value called NodeCommStr to fill in all the custom community names I generate using a VB script with Base64 encode/decode, the discovery community name and the ConfiguredNodes value, in the data source for sub-class discovery. public_node_1 public_node_2 etc...
    All in all this is working well however I have run into a few design roadblocks and I have some questions.
    1.  When I discover a set of items within the Isilon cluster the health explorer is not sorting this information alphabetically.  Is there a value I can include in the dependency roll-up to correct this?
    2.  I have run into an issue with the Isilon MIB and I'm looking for the best way to overcome the MIB's design.  They included a fan table with fan information and speed of the fans however there is no status (success{0}, warning{1}, error{2}).  I created a monitor type to compensate for this and included overrides for the warning and critical event points.  This is where I found the curve ball, seems that the fans are not the same....  There are 2 sets of fans - Chassis and Power Supply - and they have different thresholds *rolls eyes*.  Some I'm asking for the best design advice, should I create 2 classes, discoveries, monitor types, etc.?  Or can I address this issue by creating 2 monitor types with a string filter?
    3.  I've been successful in creating this MP and displaying the information as a single device however I was wondering if there was a way to create dynamic groups with sub groups.  This would have to be 100% dynamic since I can add a 9th 10th 192nd (yes 192) node to the cluster.
    Cluster
    -ClusterNode1
    -ClusterNode1Power
    -ClusterNode1Fans
    -etc
    The information is there in the NodeCommStr, I'm just in brain lock on how to design it right now.
    Again, code is raw and a work in progress so please no giggling.  Oh this is a multi post...  Code is too long.
    <Manifest>
    <Identity>
    <ID>IsilonSNMP</ID>
    <Version>1.0.1.2</Version>
    </Identity>
    <Name>IsilonSNMP</Name>
    <References>
    <Reference Alias="MicrosoftSystemCenterNetworkDeviceLibrary">
    <ID>Microsoft.SystemCenter.NetworkDevice.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="Snmp">
    <ID>System.Snmp.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="SystemHardwareLibrary">
    <ID>System.Hardware.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="Windows">
    <ID>Microsoft.Windows.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="SystemPerformanceLibrary">
    <ID>System.Performance.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="System">
    <ID>System.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="SC">
    <ID>Microsoft.SystemCenter.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    <Reference Alias="Health">
    <ID>System.Health.Library</ID>
    <Version>6.0.6278.0</Version>
    <PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
    </Reference>
    </References>
    </Manifest>
    <TypeDefinitions>
    <EntityTypes>
    <ClassTypes>
    <ClassType ID="IsilonSNMP.Class.IsilonCluster" Accessibility="Public" Abstract="false" Base="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice" Hosted="false" Singleton="false">
    <Property ID="Hostname" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    <Property ID="ConfiguredNodes" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    <!-- <Property ID="NodeCommStr" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" /> -->
    </ClassType>
    <ClassType ID="IsilonSNMP.Class.IsilonCluster.Nodes" Accessibility="Public" Abstract="false" Base="SystemHardwareLibrary!System.Chassis" Hosted="true" Singleton="false">
    <Property ID="Name" Type="string" Key="true" CaseSensitive="false" Length="256" MinLength="0" />
    </ClassType>
    <ClassType ID="IsilonSNMP.Class.IsilonCluster.PhysicalDisk" Accessibility="Public" Abstract="false" Base="SystemHardwareLibrary!System.PhysicalDisk" Hosted="true" Singleton="false">
    <Property ID="Index" Type="string" Key="true" CaseSensitive="false" Length="256" MinLength="0" />
    <!-- <Property ID="ConfiguredNodes" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" /> -->
    <Property ID="NodeCommStr" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    <Property ID="BayIndex" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    </ClassType>
    <ClassType ID="IsilonSNMP.Class.IsilonCluster.PhysicalFan" Accessibility="Public" Abstract="false" Base="SystemHardwareLibrary!System.Fan" Hosted="true" Singleton="false">
    <Property ID="Index" Type="string" Key="true" CaseSensitive="false" Length="256" MinLength="0" />
    <Property ID="NodeCommStr" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    <Property ID="FanNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0" />
    </ClassType>
    <ClassType ID="IsilonSNMP.Group.IsilonClusters" Accessibility="Public" Abstract="false" Base="System!System.Group" Hosted="false" Singleton="true" />
    </ClassTypes>
    <RelationshipTypes>
    <RelationshipType ID="IsilonSNMP.Relationship.ClusterHostsNodes" Accessibility="Internal" Abstract="false" Base="System!System.Hosting">
    <Source>IsilonSNMP.Class.IsilonCluster</Source>
    <Target>IsilonSNMP.Class.IsilonCluster.Nodes</Target>
    </RelationshipType>
    <RelationshipType ID="IsilonSNMP.Relationship.IsilonClustersGroupContainsIsilonClusters" Accessibility="Public" Abstract="false" Base="System!System.Containment">
    <Source>IsilonSNMP.Group.IsilonClusters</Source>
    <Target>IsilonSNMP.Class.IsilonCluster</Target>
    </RelationshipType>
    <RelationshipType ID="IsilonSNMP.Relationship.NodesHostsPhysicalDisk" Accessibility="Public" Abstract="false" Base="System!System.Hosting">
    <Source>IsilonSNMP.Class.IsilonCluster.Nodes</Source>
    <Target>IsilonSNMP.Class.IsilonCluster.PhysicalDisk</Target>
    </RelationshipType>
    <RelationshipType ID="IsilonSNMP.Relationship.NodesHostsPhysicalFan" Accessibility="Public" Abstract="false" Base="System!System.Hosting">
    <Source>IsilonSNMP.Class.IsilonCluster.Nodes</Source>
    <Target>IsilonSNMP.Class.IsilonCluster.PhysicalFan</Target>
    </RelationshipType>
    </RelationshipTypes>
    </EntityTypes>
    <ModuleTypes>
    <DataSourceModuleType ID="IsilonSNMP.DataSource.BasicSNMPProbe" Accessibility="Internal" Batching="false">
    <Configuration>
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="CommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="OID" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    </Configuration>
    <OverrideableParameters>
    <OverrideableParameter ID="Interval" Selector="$Config/Interval$" ParameterType="int" />
    </OverrideableParameters>
    <ModuleImplementation Isolation="Any">
    <Composite>
    <MemberModules>
    <DataSource ID="Scheduler" TypeID="System!System.Scheduler">
    <Scheduler>
    <SimpleReccuringSchedule>
    <Interval>$Config/Interval$</Interval>
    <SyncTime />
    </SimpleReccuringSchedule>
    <ExcludeDates />
    </Scheduler>
    </DataSource>
    <ProbeAction ID="SNMPProbe" TypeID="Snmp!System.SnmpProbe">
    <IsWriteAction>false</IsWriteAction>
    <IP>$Config/IPAddress$</IP>
    <CommunityString>$Config/CommStr$</CommunityString>
    <SnmpVarBinds>
    <SnmpVarBind>
    <OID>$Config/OID$</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    </SnmpVarBinds>
    </ProbeAction>
    <ConditionDetection ID="ValueFilter" TypeID="System!System.ExpressionFilter">
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="String">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>NotEqual</Operator>
    <ValueExpression>
    <Value Type="String" />
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    </ConditionDetection>
    </MemberModules>
    <Composition>
    <Node ID="ValueFilter">
    <Node ID="SNMPProbe">
    <Node ID="Scheduler" />
    </Node>
    </Node>
    </Composition>
    </Composite>
    </ModuleImplementation>
    <OutputType>Snmp!System.SnmpData</OutputType>
    </DataSourceModuleType>
    <DataSourceModuleType ID="IsilonSNMP.DataSource.DiscoverContainmentClasses" Accessibility="Internal" Batching="false">
    <Configuration>
    <IncludeSchemaTypes>
    <SchemaType>System!System.ParamListSchema</SchemaType>
    <SchemaType>System!System.Discovery.MapperSchema</SchemaType>
    </IncludeSchemaTypes>
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="ClassID" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="InstanceSettings" type="SettingsType" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    </Configuration>
    <ModuleImplementation Isolation="Any">
    <Composite>
    <MemberModules>
    <DataSource ID="Scheduler" TypeID="System!System.Scheduler">
    <Scheduler>
    <SimpleReccuringSchedule>
    <Interval>60</Interval>
    <SyncTime />
    </SimpleReccuringSchedule>
    <ExcludeDates />
    </Scheduler>
    </DataSource>
    <ConditionDetection ID="Mapper" TypeID="System!System.Discovery.ClassSnapshotDataMapper">
    <ClassId>$Config/ClassID$</ClassId>
    <InstanceSettings>$Config/InstanceSettings$</InstanceSettings>
    </ConditionDetection>
    </MemberModules>
    <Composition>
    <Node ID="Mapper">
    <Node ID="Scheduler" />
    </Node>
    </Composition>
    </Composite>
    </ModuleImplementation>
    <OutputType>System!System.Discovery.Data</OutputType>
    </DataSourceModuleType>
    <DataSourceModuleType ID="IsilonSNMP.DataSource.DiscoverCluster" Accessibility="Internal" Batching="false">
    <Configuration>
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="IP" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="CommunityString" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="SystemOID" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    </Configuration>
    <OverrideableParameters>
    <OverrideableParameter ID="Interval" Selector="$Config/Interval$" ParameterType="int" />
    </OverrideableParameters>
    <ModuleImplementation Isolation="Any">
    <Composite>
    <MemberModules>
    <DataSource ID="Scheduler" TypeID="System!System.Scheduler">
    <Scheduler>
    <SimpleReccuringSchedule>
    <Interval Unit="Seconds">$Config/Interval$</Interval>
    </SimpleReccuringSchedule>
    <ExcludeDates />
    </Scheduler>
    </DataSource>
    <ProbeAction ID="Probe" TypeID="Snmp!System.SnmpProbe">
    <IsWriteAction>false</IsWriteAction>
    <IP>$Config/IP$</IP>
    <CommunityString>$Config/CommunityString$</CommunityString>
    <SnmpVarBinds>
    <SnmpVarBind>
    <OID>.1.3.6.1.4.1.12124.1.1.4.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.4.1.12124.1.1.1.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.2.1.1.5.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.2.1.1.1.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.2.1.1.4.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.2.1.1.6.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    <SnmpVarBind>
    <OID>.1.3.6.1.2.1.1.2.0</OID>
    <Syntax>0</Syntax>
    <Value VariantType="8" />
    </SnmpVarBind>
    </SnmpVarBinds>
    </ProbeAction>
    <ConditionDetection ID="Mapper" TypeID="System!System.Discovery.FilteredClassSnapshotDataMapper">
    <Expression>
    <RegExExpression>
    <ValueExpression>
    <XPathQuery>/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>ContainsSubstring</Operator>
    <Pattern>1.3.6.1.4.1.12124.</Pattern>
    </RegExExpression>
    </Expression>
    <ClassId>$MPElement[Name="IsilonSNMP.Class.IsilonCluster"]$</ClassId>
    <InstanceSettings>
    <Settings>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</Name>
    <Value>$Data/Source$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/Name$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[5]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/SystemDescription$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[4]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/SystemContact$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[3]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/SystemLocation$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[2]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/SystemOID$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[1]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="System!System.Entity"]/DisplayName$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[5]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="IsilonSNMP.Class.IsilonCluster"]/Hostname$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[6]/Value$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="IsilonSNMP.Class.IsilonCluster"]/ConfiguredNodes$</Name>
    <Value>$Data/SnmpVarBinds/SnmpVarBind[7]/Value$</Value>
    </Setting>
    </Settings>
    </InstanceSettings>
    </ConditionDetection>
    <ConditionDetection ID="SystemOIDFilter" TypeID="System!System.ExpressionFilter">
    <Expression>
    <RegExExpression>
    <ValueExpression>
    <Value>$Config/SystemOID$</Value>
    </ValueExpression>
    <Operator>ContainsSubstring</Operator>
    <Pattern>1.3.6.1.4.1.12124.</Pattern>
    </RegExExpression>
    </Expression>
    </ConditionDetection>
    </MemberModules>
    <Composition>
    <Node ID="Mapper">
    <Node ID="Probe">
    <Node ID="SystemOIDFilter">
    <Node ID="Scheduler" />
    </Node>
    </Node>
    </Node>
    </Composition>
    </Composite>
    </ModuleImplementation>
    <OutputType>System!System.Discovery.Data</OutputType>
    </DataSourceModuleType>
    <DataSourceModuleType ID="IsilonSNMP.DataSource.DiscoverPhysicalDisk" Accessibility="Internal" Batching="false">
    <Configuration>
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="CommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="ConfiguredNodes" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="BayIndex" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="NodeCommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    </Configuration>
    <OverrideableParameters>
    <OverrideableParameter ID="Interval" Selector="$Config/Interval$" ParameterType="int" />
    </OverrideableParameters>
    <ModuleImplementation Isolation="Any">
    <Composite>
    <MemberModules>
    <DataSource ID="Scheduler" TypeID="System!System.Scheduler">
    <Scheduler>
    <SimpleReccuringSchedule>
    <Interval>$Config/Interval$</Interval>
    <SyncTime />
    </SimpleReccuringSchedule>
    <ExcludeDates />
    </Scheduler>
    </DataSource>
    <ProbeAction ID="ScriptDiscovery" TypeID="Windows!Microsoft.Windows.ScriptDiscoveryProbe">
    <ScriptName>DiscoverIsilonDisk.vbs</ScriptName>
    <Arguments>$Config/IPAddress$ $Config/CommStr$ $MPElement$ $Target/Id$ $Config/ConfiguredNodes$</Arguments>
    <ScriptBody>
    <![CDATA['Discover PhysicalDisk
    Dim oAPI, oDiscoveryData, oInst, objWMIServices, objWMILocator, oArgs
    set oArgs = Wscript.Arguments
    if oArgs.Count <5 Then
    Wscript.Quit -1
    End If
    DeviceIP = oArgs(0)
    CommStr = oArgs(1)
    SourceID = oArgs(2)
    ManagedEntityId = oArgs(3)
    StrConfiguredNodes = oArgs(4)
    CommStr = Decode(CommStr)
    ConfiguredNodesCommStr = cstr(CommStr)
    wscript.echo CommStr
    Set oAPI = CreateObject("MOM.ScriptAPI")
    set oDiscoveryData = oAPI.CreateDiscoveryData(0, SourceId, ManagedEntityId)
    Set objWMILocator = CreateObject("WbemScripting.SWbemLocator")
    Set objWMIServices = objWMiLocator.ConnectServer("","root\snmp\localhost")
    'Name community name
    GetPhysicalDisks
    'Created community names
    For i = 1 to StrConfiguredNodes
    CommStr = ConfiguredNodesCommStr & "_node_" & i
    GetPhysicalDisks
    Next
    'Return all data to SCOM
    Call oAPI.Return(oDiscoveryData)
    Sub GetPhysicalDisks
    on error resume next
    Set objWmiNamedValueSet = CreateObject("WbemScripting.SWbemNamedValueSet")
    objWmiNamedValueSet.Add "AgentAddress", cstr(DeviceIP)
    objWmiNamedValueSet.Add "AgentReadCommunityName", cstr(CommStr)
    Set colPhysicalDisk = objWmiServices.InstancesOf("SNMP_ISILON_MIB_diskTable", , objWMINamedValueset)
    For each objItem in colPhysicalDisk
    nIndex = objItem.diskBay
    sDesc = objItem.diskSerialNumber
    if nIndex > 0 then
    set oInst = oDiscoveryData.CreateClassInstance("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalDisk']$")
    call oInst.AddProperty("$MPElement[Name='MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice']/IPAddress$", DeviceIP)
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalDisk']/Index$", cstr(CommStr) & "-" & cdbl(nIndex))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalDisk']/NodeCommStr$", Encode(CommStr))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalDisk']/BayIndex$", cdbl(nIndex))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.Nodes']/Name$", "Cluster")
    call oInst.AddProperty("$MPElement[Name='System!System.Entity']/DisplayName$", "SNMP Host " & cstr(CommStr) & " - Bay " & nIndex & " - Serial Number " & HexToString(sDesc))
    'call oInst.AddProperty("$MPElement[Name='System!System.Entity']/DisplayName$", HexToString(sDesc))
    call oDiscoveryData.AddInstance(oInst)
    'Test Section
    'wscript.echo Base64Encode(CommStr)
    'wscript.echo Base64Encoder(CommStr)
    'wscript.Echo CommStr
    'wscript.Echo nIndex
    'Wscript.Echo HexToString(sDesc)
    'wscript.echo cdbl(nIndex) & cstr(CommStr)
    end if
    Next
    on error goto 0
    End Sub
    Function Decode(strB64)
    strXML = "<B64DECODE xmlns:dt=" & Chr(34) & _
    "urn:schemas-microsoft-com:datatypes" & Chr(34) & " " & _
    "dt:dt=" & Chr(34) & "bin.base64" & Chr(34) & ">" & _
    strB64 & "</B64DECODE>"
    Set oXMLDoc = CreateObject("MSXML2.DOMDocument.3.0")
    oXMLDoc.LoadXML(strXML)
    decode = oXMLDoc.selectsinglenode("B64DECODE").nodeTypedValue
    set oXMLDoc = nothing
    End Function
    Function Encode(Str)
    'Use ADODB.Stream to write Ansi string to Unicode stream
    Set objStream = CreateObject("ADODB.Stream")
    objStream.Type = 2
    objStream.Open
    objStream.Charset = "unicode"
    objStream.WriteText Str
    objstream.Flush
    'Read the stream back as a byte array
    objStream.Position = 0
    objStream.Type = 1
    temp = objstream.read(2) 'read two bytes of the stream to discard the byte order mark
    bArray = objStream.Read
    objStream.Close
    'Convert byte array to Base64
    set objXML = createobject("MSXML2.DOMDocument.3.0")
    Set objNode = objXML.createElement("b64")
    objNode.dataType = "bin.base64"
    objNode.nodeTypedValue = bArray
    Encode = objNode.Text
    Set Stream = Nothing
    set objNode = nothing
    set objXML = nothing
    End Function
    Function HexToString(str)
    on error resume next
    sOutput = ""
    For x = 1 To len(str) Step 2
    sChar = Chr(Clng("&h" & Mid(str,x,2)))
    sOutput = sOutput & sChar
    Next
    if err.number = 0 then
    HexToString = sOutput
    Else
    HexToString = str
    end if
    End Function
    set oInst = nothing
    set oDiscoveryData = nothing
    set oArgs = nothing
    set oAPI = nothing
    set objWMILocator = nothing
    set objWMIServices = nothing
    set objWMINamedValueSet = nothing
    ]]>
    </ScriptBody>
    <TimeoutSeconds>120</TimeoutSeconds>
    </ProbeAction>
    </MemberModules>
    <Composition>
    <Node ID="ScriptDiscovery">
    <Node ID="Scheduler" />
    </Node>
    </Composition>
    </Composite>
    </ModuleImplementation>
    <OutputType>System!System.Discovery.Data</OutputType>
    </DataSourceModuleType>

    <DataSourceModuleType ID="IsilonSNMP.DataSource.DiscoverPhysicalFan" Accessibility="Internal" Batching="false">
    <Configuration>
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="CommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="ConfiguredNodes" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="FanNumber" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="NodeCommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="FanSpeedHighCritical" type="xsd:integer" />
    <xsd:element minOccurs="1" name="FanSpeedLowWarn" type="xsd:integer" />
    <xsd:element minOccurs="1" name="FanSpeedLowCritical" type="xsd:integer" />
    </Configuration>
    <OverrideableParameters>
    <OverrideableParameter ID="Interval" Selector="$Config/Interval$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedHighCritical" Selector="$Config/FanSpeedHighCritical$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedLowWarn" Selector="$Config/FanSpeedLowWarn$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedLowCritical" Selector="$Config/FanSpeedLowCritical$" ParameterType="int" />
    </OverrideableParameters>
    <ModuleImplementation Isolation="Any">
    <Composite>
    <MemberModules>
    <DataSource ID="Scheduler" TypeID="System!System.Scheduler">
    <Scheduler>
    <SimpleReccuringSchedule>
    <Interval>$Config/Interval$</Interval>
    <SyncTime />
    </SimpleReccuringSchedule>
    <ExcludeDates />
    </Scheduler>
    </DataSource>
    <ProbeAction ID="ScriptDiscovery" TypeID="Windows!Microsoft.Windows.ScriptDiscoveryProbe">
    <ScriptName>DiscoverIsilonPhysicalFan.vbs</ScriptName>
    <Arguments>$Config/IPAddress$ $Config/CommStr$ $MPElement$ $Target/Id$ $Config/ConfiguredNodes$</Arguments>
    <ScriptBody>
    <![CDATA['Discover PhysicalFan
    Dim oAPI, oDiscoveryData, oInst, objWMIServices, objWMILocator, oArgs
    set oArgs = Wscript.Arguments
    if oArgs.Count <5 Then
    Wscript.Quit -1
    End If
    DeviceIP = oArgs(0)
    CommStr = oArgs(1)
    SourceID = oArgs(2)
    ManagedEntityId = oArgs(3)
    StrConfiguredNodes = oArgs(4)
    CommStr = Decode(CommStr)
    ConfiguredNodesCommStr = cstr(CommStr)
    wscript.echo CommStr
    Set oAPI = CreateObject("MOM.ScriptAPI")
    set oDiscoveryData = oAPI.CreateDiscoveryData(0, SourceId, ManagedEntityId)
    Set objWMILocator = CreateObject("WbemScripting.SWbemLocator")
    Set objWMIServices = objWMiLocator.ConnectServer("","root\snmp\localhost")
    'Name community name
    GetPhysicalFan
    'Created community names
    For i = 1 to StrConfiguredNodes
    CommStr = ConfiguredNodesCommStr & "_node_" & i
    GetPhysicalFan
    Next
    'Return all data to SCOM
    Call oAPI.Return(oDiscoveryData)
    Sub GetPhysicalFan
    on error resume next
    Set objWmiNamedValueSet = CreateObject("WbemScripting.SWbemNamedValueSet")
    objWmiNamedValueSet.Add "AgentAddress", cstr(DeviceIP)
    objWmiNamedValueSet.Add "AgentReadCommunityName", cstr(CommStr)
    Set colPhysicalFan = objWmiServices.InstancesOf("SNMP_ISILON_MIB_FanTable", , objWMINamedValueset)
    For each objItem in colPhysicalFan
    nIndex = objItem.fanNumber
    sDesc = objItem.fanDescription
    if nIndex > 0 then
    set oInst = oDiscoveryData.CreateClassInstance("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalFan']$")
    call oInst.AddProperty("$MPElement[Name='MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice']/IPAddress$", DeviceIP)
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalFan']/Index$", cstr(CommStr) & "-" & cdbl(nIndex))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalFan']/NodeCommStr$", Encode(CommStr))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.PhysicalFan']/FanNumber$", cdbl(nIndex))
    call oInst.AddProperty("$MPElement[Name='IsilonSNMP.Class.IsilonCluster.Nodes']/Name$", "Cluster")
    'call oInst.AddProperty("$MPElement[Name='System!System.Entity']/DisplayName$", "SNMP Host " & cstr(CommStr) & " - Bay " & nIndex & " - Serial Number " & HexToString(sDesc))
    call oInst.AddProperty("$MPElement[Name='System!System.Entity']/DisplayName$", "SNMP Host " & cstr(CommStr) & " - " & HexToString(sDesc))
    call oDiscoveryData.AddInstance(oInst)
    'Test Section
    'wscript.echo Base64Encode(CommStr)
    'wscript.echo Base64Encoder(CommStr)
    'wscript.Echo CommStr
    'wscript.Echo nIndex
    'Wscript.Echo HexToString(sDesc)
    'wscript.echo cdbl(nIndex) & cstr(CommStr)
    end if
    Next
    on error goto 0
    End Sub
    Function Decode(strB64)
    strXML = "<B64DECODE xmlns:dt=" & Chr(34) & _
    "urn:schemas-microsoft-com:datatypes" & Chr(34) & " " & _
    "dt:dt=" & Chr(34) & "bin.base64" & Chr(34) & ">" & _
    strB64 & "</B64DECODE>"
    Set oXMLDoc = CreateObject("MSXML2.DOMDocument.3.0")
    oXMLDoc.LoadXML(strXML)
    decode = oXMLDoc.selectsinglenode("B64DECODE").nodeTypedValue
    set oXMLDoc = nothing
    End Function
    Function Encode(Str)
    'Use ADODB.Stream to write Ansi string to Unicode stream
    Set objStream = CreateObject("ADODB.Stream")
    objStream.Type = 2
    objStream.Open
    objStream.Charset = "unicode"
    objStream.WriteText Str
    objstream.Flush
    'Read the stream back as a byte array
    objStream.Position = 0
    objStream.Type = 1
    temp = objstream.read(2) 'read two bytes of the stream to discard the byte order mark
    bArray = objStream.Read
    objStream.Close
    'Convert byte array to Base64
    set objXML = createobject("MSXML2.DOMDocument.3.0")
    Set objNode = objXML.createElement("b64")
    objNode.dataType = "bin.base64"
    objNode.nodeTypedValue = bArray
    Encode = objNode.Text
    Set Stream = Nothing
    set objNode = nothing
    set objXML = nothing
    End Function
    Function HexToString(str)
    on error resume next
    sOutput = ""
    For x = 1 To len(str) Step 2
    sChar = Chr(Clng("&h" & Mid(str,x,2)))
    sOutput = sOutput & sChar
    Next
    if err.number = 0 then
    HexToString = sOutput
    Else
    HexToString = str
    end if
    End Function
    set oInst = nothing
    set oDiscoveryData = nothing
    set oArgs = nothing
    set oAPI = nothing
    set objWMILocator = nothing
    set objWMIServices = nothing
    set objWMINamedValueSet = nothing
    ]]>
    </ScriptBody>
    <TimeoutSeconds>120</TimeoutSeconds>
    </ProbeAction>
    </MemberModules>
    <Composition>
    <Node ID="ScriptDiscovery">
    <Node ID="Scheduler" />
    </Node>
    </Composition>
    </Composite>
    </ModuleImplementation>
    <OutputType>System!System.Discovery.Data</OutputType>
    </DataSourceModuleType>
    </ModuleTypes>
    <MonitorTypes>
    <UnitMonitorType ID="IsilonSNMP.MonitorType.PhysicalDiskStatus" Accessibility="Internal">
    <MonitorTypeStates>
    <MonitorTypeState ID="PhysicalDiskOK" NoDetection="false" />
    <MonitorTypeState ID="PhysicalDiskNotOK" NoDetection="false" />
    </MonitorTypeStates>
    <Configuration>
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="OID" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="NodeCommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    </Configuration>
    <MonitorImplementation>
    <MemberModules>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.BasicSNMPProbe">
    <Interval>$Config/Interval$</Interval>
    <IPAddress>$Config/IPAddress$</IPAddress>
    <CommStr>$Config/NodeCommStr$</CommStr>
    <OID>$Config/OID$</OID>
    </DataSource>
    <ConditionDetection ID="CDPhysicalDiskOK" TypeID="System!System.ExpressionFilter">
    <Expression>
    <RegExExpression>
    <ValueExpression>
    <XPathQuery Type="String">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>ContainsSubstring</Operator>
    <Pattern>HEALTHY</Pattern>
    </RegExExpression>
    </Expression>
    </ConditionDetection>
    <ConditionDetection ID="CDPhysicalDiskNotOK" TypeID="System!System.ExpressionFilter">
    <Expression>
    <RegExExpression>
    <ValueExpression>
    <XPathQuery Type="String">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>DoesNotContainSubstring</Operator>
    <Pattern>HEALTHY</Pattern>
    </RegExExpression>
    </Expression>
    </ConditionDetection>
    </MemberModules>
    <RegularDetections>
    <RegularDetection MonitorTypeStateID="PhysicalDiskOK">
    <Node ID="CDPhysicalDiskOK">
    <Node ID="DS1" />
    </Node>
    </RegularDetection>
    <RegularDetection MonitorTypeStateID="PhysicalDiskNotOK">
    <Node ID="CDPhysicalDiskNotOK">
    <Node ID="DS1" />
    </Node>
    </RegularDetection>
    </RegularDetections>
    </MonitorImplementation>
    </UnitMonitorType>
    <UnitMonitorType ID="IsilonSNMP.MonitorType.PhysicalFanStatus" Accessibility="Internal">
    <MonitorTypeStates>
    <MonitorTypeState ID="PhysicalFanOK" NoDetection="false" />
    <MonitorTypeState ID="PhysicalFanWarn" NoDetection="false" />
    <MonitorTypeState ID="PhysicalFanCritical" NoDetection="false" />
    </MonitorTypeStates>
    <Configuration>
    <xsd:element minOccurs="1" name="Interval" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="IPAddress" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="OID" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="NodeCommStr" type="xsd:string" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
    <xsd:element minOccurs="1" name="FanSpeedHighCritical" type="xsd:integer" />
    <xsd:element minOccurs="1" name="FanSpeedLowWarn" type="xsd:integer" />
    <xsd:element minOccurs="1" name="FanSpeedLowCritical" type="xsd:integer" />
    </Configuration>
    <OverrideableParameters>
    <OverrideableParameter ID="Interval" Selector="$Config/Interval$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedHighCritical" Selector="$Config/FanSpeedHighCritical$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedLowWarn" Selector="$Config/FanSpeedLowWarn$" ParameterType="int" />
    <OverrideableParameter ID="FanSpeedLowCritical" Selector="$Config/FanSpeedLowCritical$" ParameterType="int" />
    </OverrideableParameters>
    <MonitorImplementation>
    <MemberModules>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.BasicSNMPProbe">
    <Interval>$Config/Interval$</Interval>
    <IPAddress>$Config/IPAddress$</IPAddress>
    <CommStr>$Config/NodeCommStr$</CommStr>
    <OID>$Config/OID$</OID>
    </DataSource>
    <ConditionDetection ID="CDPhysicalFanOK" TypeID="System!System.ExpressionFilter">
    <Expression>
    <And>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>Less</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedHighCritical$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>Greater</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedLowWarn$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    </And>
    </Expression>
    </ConditionDetection>
    <ConditionDetection ID="CDPhysicalFanWarn" TypeID="System!System.ExpressionFilter">
    <Expression>
    <And>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>LessEqual</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedLowWarn$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>Greater</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedLowWarn$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    </And>
    </Expression>
    </ConditionDetection>
    <ConditionDetection ID="CDPhysicalFanCritical" TypeID="System!System.ExpressionFilter">
    <Expression>
    <Or>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>GreaterEqual</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedHighCritical$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    <Expression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="Integer">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>LessEqual</Operator>
    <ValueExpression>
    <Value Type="Integer">$Config/FanSpeedLowCritical$</Value>
    </ValueExpression>
    </SimpleExpression>
    </Expression>
    </Or>
    </Expression>
    </ConditionDetection>
    </MemberModules>
    <RegularDetections>
    <RegularDetection MonitorTypeStateID="PhysicalFanOK">
    <Node ID="CDPhysicalFanOK">
    <Node ID="DS1" />
    </Node>
    </RegularDetection>
    <RegularDetection MonitorTypeStateID="PhysicalFanWarn">
    <Node ID="CDPhysicalFanWarn">
    <Node ID="DS1" />
    </Node>
    </RegularDetection>
    <RegularDetection MonitorTypeStateID="PhysicalFanCritical">
    <Node ID="CDPhysicalFanCritical">
    <Node ID="DS1" />
    </Node>
    </RegularDetection>
    </RegularDetections>
    </MonitorImplementation>
    </UnitMonitorType>
    </MonitorTypes>
    </TypeDefinitions>
    <Monitoring>
    <Discoveries>
    <Discovery ID="IsilonSNMP.Discovery.Cluster" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster" ConfirmDelivery="true" Remotable="true" Priority="Normal">
    <Category>Discovery</Category>
    <DiscoveryTypes>
    <DiscoveryClass TypeID="IsilonSNMP.Class.IsilonCluster.Nodes" />
    <DiscoveryRelationship TypeID="IsilonSNMP.Relationship.ClusterHostsNodes" />
    </DiscoveryTypes>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.DiscoverContainmentClasses">
    <IPAddress>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IPAddress>
    <ClassID>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.Nodes"]$</ClassID>
    <InstanceSettings>
    <Settings>
    <Setting>
    <Name>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</Name>
    <Value>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="System!System.Entity"]/DisplayName$</Name>
    <Value>Cluster</Value>
    </Setting>
    <Setting>
    <Name>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.Nodes"]/Name$</Name>
    <Value>Cluster</Value>
    </Setting>
    </Settings>
    </InstanceSettings>
    </DataSource>
    </Discovery>
    <Discovery ID="IsilonSNMP.Discovery.IsilonCluster" Enabled="true" Target="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice" ConfirmDelivery="true" Remotable="true" Priority="Normal">
    <Category>Discovery</Category>
    <DiscoveryTypes>
    <DiscoveryClass TypeID="IsilonSNMP.Class.IsilonCluster" />
    </DiscoveryTypes>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.DiscoverCluster">
    <Interval>600</Interval>
    <IP>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IP>
    <CommunityString>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/CommunityString$</CommunityString>
    <SystemOID>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/SystemOID$</SystemOID>
    </DataSource>
    </Discovery>
    <Discovery ID="IsilonSNMP.Discovery.IsilonClustersGroup" Enabled="true" Target="IsilonSNMP.Group.IsilonClusters" ConfirmDelivery="true" Remotable="true" Priority="Normal">
    <Category>Discovery</Category>
    <DiscoveryTypes>
    <DiscoveryRelationship TypeID="IsilonSNMP.Relationship.IsilonClustersGroupContainsIsilonClusters" />
    </DiscoveryTypes>
    <DataSource ID="GP1" TypeID="SC!Microsoft.SystemCenter.GroupPopulator">
    <RuleId>$MPElement$</RuleId>
    <GroupInstanceId>$MPElement[Name="IsilonSNMP.Group.IsilonClusters"]$</GroupInstanceId>
    <MembershipRules>
    <MembershipRule>
    <MonitoringClass>$MPElement[Name="IsilonSNMP.Class.IsilonCluster"]$</MonitoringClass>
    <RelationshipClass>$MPElement[Name="IsilonSNMP.Relationship.IsilonClustersGroupContainsIsilonClusters"]$</RelationshipClass>
    <Expression>
    <RegExExpression>
    <ValueExpression>
    <Property>$MPElement[Name="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</Property>
    </ValueExpression>
    <Operator>ContainsSubstring</Operator>
    <Pattern>.</Pattern>
    </RegExExpression>
    </Expression>
    </MembershipRule>
    </MembershipRules>
    </DataSource>
    </Discovery>
    <Discovery ID="IsilonSNMP.Discovery.PhysicalDisk" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.Nodes" ConfirmDelivery="true" Remotable="true" Priority="Normal">
    <Category>Discovery</Category>
    <DiscoveryTypes>
    <DiscoveryClass TypeID="IsilonSNMP.Class.IsilonCluster.PhysicalDisk" />
    <DiscoveryRelationship TypeID="IsilonSNMP.Relationship.NodesHostsPhysicalDisk" />
    </DiscoveryTypes>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.DiscoverPhysicalDisk">
    <IPAddress>$Target/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IPAddress>
    <CommStr>$Target/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/CommunityString$</CommStr>
    <Interval>7800</Interval>
    <ConfiguredNodes>$Target/Host/Property[Type="IsilonSNMP.Class.IsilonCluster"]/ConfiguredNodes$</ConfiguredNodes>
    <BayIndex>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.PhysicalDisk"]/BayIndex$</BayIndex>
    <NodeCommStr>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.PhysicalDisk"]/NodeCommStr$</NodeCommStr>
    </DataSource>
    </Discovery>
    <Discovery ID="IsilonSNMP.Discovery.PhysicalFan" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.Nodes" ConfirmDelivery="true" Remotable="true" Priority="Normal">
    <Category>Discovery</Category>
    <DiscoveryTypes>
    <DiscoveryClass TypeID="IsilonSNMP.Class.IsilonCluster.PhysicalFan" />
    <DiscoveryRelationship TypeID="IsilonSNMP.Relationship.NodesHostsPhysicalFan" />
    </DiscoveryTypes>
    <DataSource ID="DS1" TypeID="IsilonSNMP.DataSource.DiscoverPhysicalFan">
    <IPAddress>$Target/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IPAddress>
    <CommStr>$Target/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/CommunityString$</CommStr>
    <Interval>8000</Interval>
    <ConfiguredNodes>$Target/Host/Property[Type="IsilonSNMP.Class.IsilonCluster"]/ConfiguredNodes$</ConfiguredNodes>
    <FanNumber>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.PhysicalFan"]/FanNumber$</FanNumber>
    <NodeCommStr>$MPElement[Name="IsilonSNMP.Class.IsilonCluster.PhysicalFan"]/NodeCommStr$</NodeCommStr>
    <FanSpeedHighCritical>14500</FanSpeedHighCritical>
    <FanSpeedLowWarn>3400</FanSpeedLowWarn>
    <FanSpeedLowCritical>3000</FanSpeedLowCritical>
    </DataSource>
    </Discovery>
    </Discoveries>
    <Monitors>
    <UnitMonitor ID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70" Accessibility="Public" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="Snmp!System.SnmpTrapProvider.2SingleEvent2StateMonitorType" ConfirmDelivery="false">
    <Category>Custom</Category>
    <AlertSettings AlertMessage="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70_AlertMessageResourceID">
    <AlertOnState>Warning</AlertOnState>
    <AutoResolve>true</AutoResolve>
    <AlertPriority>Normal</AlertPriority>
    <AlertSeverity>MatchMonitorHealth</AlertSeverity>
    </AlertSettings>
    <OperationalStates>
    <OperationalState ID="UIGeneratedOpStateId843498792d7d4fbf80d83f3939255dd9" MonitorTypeStateID="SecondEventRaised" HealthState="Success" />
    <OperationalState ID="UIGeneratedOpStateId9fd776cd21a747c5994738e863b31fb9" MonitorTypeStateID="FirstEventRaised" HealthState="Warning" />
    </OperationalStates>
    <Configuration>
    <FirstIP>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</FirstIP>
    <FirstCommunityString>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/CommunityString$</FirstCommunityString>
    <FirstAllTraps>false</FirstAllTraps>
    <FirstVersion>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/Version$</FirstVersion>
    <FirstOIDProps>
    <OIDProp>.1.3.6.1.4.1.12124.1.1.2.0</OIDProp>
    </FirstOIDProps>
    <FirstExpression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="String">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>Equal</Operator>
    <ValueExpression>
    <Value Type="String">1</Value>
    </ValueExpression>
    </SimpleExpression>
    </FirstExpression>
    <SecondIP>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</SecondIP>
    <SecondCommunityString>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/CommunityString$</SecondCommunityString>
    <SecondAllTraps>false</SecondAllTraps>
    <SecondVersion>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/Version$</SecondVersion>
    <SecondOIDProps>
    <OIDProp>.1.3.6.1.4.1.12124.1.1.2.0</OIDProp>
    </SecondOIDProps>
    <SecondExpression>
    <SimpleExpression>
    <ValueExpression>
    <XPathQuery Type="String">/DataItem/SnmpVarBinds/SnmpVarBind[1]/Value</XPathQuery>
    </ValueExpression>
    <Operator>NotEqual</Operator>
    <ValueExpression>
    <Value Type="String">1</Value>
    </ValueExpression>
    </SimpleExpression>
    </SecondExpression>
    </Configuration>
    </UnitMonitor>
    <UnitMonitor ID="IsilonSNMP.Monitor.PhysicalDiskStatus" Accessibility="Internal" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.PhysicalDisk" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="IsilonSNMP.MonitorType.PhysicalDiskStatus" ConfirmDelivery="true">
    <Category>AvailabilityHealth</Category>
    <AlertSettings AlertMessage="IsilonSNMP.Monitor.PhysicalDiskStatus_AlertMessageResourceID">
    <AlertOnState>Warning</AlertOnState>
    <AutoResolve>true</AutoResolve>
    <AlertPriority>Normal</AlertPriority>
    <AlertSeverity>MatchMonitorHealth</AlertSeverity>
    <AlertParameters>
    <AlertParameter1>$Target/Property[Type="System!System.Entity"]/DisplayName$</AlertParameter1>
    <AlertParameter2>$Data/Context/SnmpVarBinds/SnmpVarBind[1]/Value$</AlertParameter2>
    </AlertParameters>
    </AlertSettings>
    <OperationalStates>
    <OperationalState ID="IsilonSNMP.Monitor.PhysicalDiskStatus_PhysicalDiskOK" MonitorTypeStateID="PhysicalDiskOK" HealthState="Success" />
    <OperationalState ID="IsilonSNMP.Monitor.PhysicalDiskStatus_PhysicalDiskNotOK" MonitorTypeStateID="PhysicalDiskNotOK" HealthState="Warning" />
    </OperationalStates>
    <Configuration>
    <Interval>120</Interval>
    <IPAddress>$Target/Host/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IPAddress>
    <OID>.1.3.6.1.4.1.12124.2.52.1.5.$Target/Property[Type="IsilonSNMP.Class.IsilonCluster.PhysicalDisk"]/BayIndex$</OID>
    <NodeCommStr>$Target/Property[Type="IsilonSNMP.Class.IsilonCluster.PhysicalDisk"]/NodeCommStr$</NodeCommStr>
    </Configuration>
    </UnitMonitor>
    <UnitMonitor ID="IsilonSNMP.Monitor.PhysicalFanStatus" Accessibility="Internal" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.PhysicalFan" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="IsilonSNMP.MonitorType.PhysicalFanStatus" ConfirmDelivery="true">
    <Category>AvailabilityHealth</Category>
    <AlertSettings AlertMessage="IsilonSNMP.Monitor.PhysicalFanStatus_AlertMessageResourceID">
    <AlertOnState>Warning</AlertOnState>
    <AutoResolve>true</AutoResolve>
    <AlertPriority>Normal</AlertPriority>
    <AlertSeverity>MatchMonitorHealth</AlertSeverity>
    <AlertParameters>
    <AlertParameter1>$Target/Property[Type="System!System.Entity"]/DisplayName$</AlertParameter1>
    <AlertParameter2>$Data/Context/SnmpVarBinds/SnmpVarBind[1]/Value$</AlertParameter2>
    </AlertParameters>
    </AlertSettings>
    <OperationalStates>
    <OperationalState ID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanOK" MonitorTypeStateID="PhysicalFanOK" HealthState="Success" />
    <OperationalState ID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanWarn" MonitorTypeStateID="PhysicalFanWarn" HealthState="Warning" />
    <OperationalState ID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanCritical" MonitorTypeStateID="PhysicalFanCritical" HealthState="Error" />
    </OperationalStates>
    <Configuration>
    <Interval>120</Interval>
    <IPAddress>$Target/Host/Host/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary!Microsoft.SystemCenter.NetworkDevice"]/IPAddress$</IPAddress>
    <OID>.1.3.6.1.4.1.12124.2.53.1.4.$Target/Property[Type="IsilonSNMP.Class.IsilonCluster.PhysicalFan"]/FanNumber$</OID>
    <NodeCommStr>$Target/Property[Type="IsilonSNMP.Class.IsilonCluster.PhysicalFan"]/NodeCommStr$</NodeCommStr>
    <FanSpeedHighCritical>14500</FanSpeedHighCritical>
    <FanSpeedLowWarn>3400</FanSpeedLowWarn>
    <FanSpeedLowCritical>3000</FanSpeedLowCritical>
    </Configuration>
    </UnitMonitor>
    <DependencyMonitor ID="IsilonSNMP.Monitor.ClusterPhysicalDiskAvailabilityDependency" Accessibility="Internal" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.Nodes" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" RelationshipType="IsilonSNMP.Relationship.NodesHostsPhysicalDisk" MemberMonitor="IsilonSNMP.Monitor.PhysicalDiskStatus">
    <Category>AvailabilityHealth</Category>
    <Algorithm>WorstOf</Algorithm>
    <MemberUnAvailable>Error</MemberUnAvailable>
    </DependencyMonitor>
    <DependencyMonitor ID="IsilonSNMP.Monitor.ClusterPhysicalFanAvailabilityDependency" Accessibility="Internal" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster.Nodes" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" RelationshipType="IsilonSNMP.Relationship.NodesHostsPhysicalFan" MemberMonitor="IsilonSNMP.Monitor.PhysicalFanStatus">
    <Category>AvailabilityHealth</Category>
    <Algorithm>WorstOf</Algorithm>
    <MemberUnAvailable>Error</MemberUnAvailable>
    </DependencyMonitor>
    <DependencyMonitor ID="IsilonSNMP.Monitor.ClusterClusterAvailabilityDependency" Accessibility="Internal" Enabled="true" Target="IsilonSNMP.Class.IsilonCluster" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" RelationshipType="IsilonSNMP.Relationship.ClusterHostsNodes" MemberMonitor="Health!System.Health.AvailabilityState">
    <Category>AvailabilityHealth</Category>
    <Algorithm>WorstOf</Algorithm>
    <MemberUnAvailable>Error</MemberUnAvailable>
    </DependencyMonitor>
    </Monitors>
    </Monitoring>
    <Presentation>
    <StringResources>
    <StringResource ID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70_AlertMessageResourceID" />
    <StringResource ID="AlertMessageIDb1a3848769824949889fcc4c159cf462" />
    <StringResource ID="IsilonSNMP.Monitor.PhysicalDiskStatus_AlertMessageResourceID" />
    <StringResource ID="IsilonSNMP.Monitor.PhysicalFanStatus_AlertMessageResourceID" />
    </StringResources>
    </Presentation>
    <LanguagePacks>
    <LanguagePack ID="ENU" IsDefault="true">
    <DisplayStrings>
    <DisplayString ElementID="IsilonSNMP">
    <Name>Isilon SNMP MP</Name>
    <Description>Management pack to discover a Isilon cluster running OneFS 5.5</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster">
    <Name>Isilon Cluster</Name>
    <Description>Isilon SNMP Device</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster" SubElementID="Hostname">
    <Name>Hostname</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster" SubElementID="ConfiguredNodes">
    <Name>ConfiguredNodes</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.Nodes" SubElementID="Name">
    <Name>Name</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.Nodes">
    <Name>Isilon Cluster Hosts Nodes</Name>
    <Description>Containment class for the Isilon cluster with components such as hard disks, fans, power supplies, etc.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Relationship.ClusterHostsNodes">
    <Name>Isilon Cluster Hosts Nodes</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Discovery.IsilonCluster">
    <Name>Discover Isilon Cluster</Name>
    <Description>Discovery of the Isilon Cluster using OID strings from RFC1213.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.DataSource.BasicSNMPProbe">
    <Name>Isilon Basic Probe Data Source</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.DataSource.DiscoverCluster">
    <Name>Discover Isilon Cluster</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Relationship.IsilonClustersGroupContainsIsilonClusters">
    <Name>Isilon Devices Group Contains Isilon Cluster</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Discovery.Cluster">
    <Name>Discover Isilon Cluster Containment Class</Name>
    <Description>Discovers the Cluster containment class, which hosts managed objects such as fans</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Discovery.IsilonClustersGroup">
    <Name>Isilon Deivce Group Populator</Name>
    </DisplayString>
    <DisplayString ElementID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70">
    <Name>PlaceHolder</Name>
    <Description>Place Holder to detect isilon cluster</Description>
    </DisplayString>
    <DisplayString ElementID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70" SubElementID="UIGeneratedOpStateId843498792d7d4fbf80d83f3939255dd9">
    <Name>Second Event Raised</Name>
    </DisplayString>
    <DisplayString ElementID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70" SubElementID="UIGeneratedOpStateId9fd776cd21a747c5994738e863b31fb9">
    <Name>First Event Raised</Name>
    </DisplayString>
    <DisplayString ElementID="UIGeneratedMonitore2c4dd195da8497bb99c9711e4134d70_AlertMessageResourceID">
    <Name>PlaceHolder</Name>
    <Description>placeholder alert to detect isilon</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalDiskStatus">
    <Name>Isilon PhysicalDisk Status Monitor</Name>
    <Description>Monitor that generates an alert when the PhysicalDisk status is not ok.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalDiskStatus" SubElementID="IsilonSNMP.Monitor.PhysicalDiskStatus_PhysicalDiskOK">
    <Name>PhysicalDiskOK</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalDiskStatus" SubElementID="IsilonSNMP.Monitor.PhysicalDiskStatus_PhysicalDiskNotOK">
    <Name>PhysicalDiskOK</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalDiskStatus_AlertMessageResourceID">
    <Name>Isilon PhysicalDisk Status</Name>
    <Description>The Disk ({0}) is in a warning or error state. The Disk state is: {1}.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.PhysicalDisk">
    <Name>Isilon Disk</Name>
    <Description>Disk</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.PhysicalDisk" SubElementID="Index">
    <Name>Index</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Relationship.NodesHostsPhysicalDisk">
    <Name>Isilon Cluster Hosts PhysicalDisk</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Discovery.PhysicalDisk">
    <Name>Discover Isilon Cluster Physical Disks</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.DataSource.DiscoverPhysicalDisk">
    <Name>Discover Isilon Cluster PhysicalDisk</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.ClusterPhysicalDiskAvailabilityDependency">
    <Name>Isilon Disk</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalFanStatus">
    <Name>Isilon PhysicalFan Status Monitor</Name>
    <Description>Monitor that generates an alert when the PhysicalFan speed is not within a premited range.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalFanStatus" SubElementID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanOK">
    <Name>PhysicalFanOK</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalFanStatus" SubElementID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanWarn">
    <Name>PhysicalFanWarn</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalFanStatus" SubElementID="IsilonSNMP.Monitor.PhysicalFanStatus_PhysicalFanCritical">
    <Name>PhysicalFanCritical</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.PhysicalFanStatus_AlertMessageResourceID">
    <Name>Isilon PhysicalFan Status</Name>
    <Description>The Fan ({0}) is in a warning or error state. Current Fan speed is: {1}.</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.PhysicalFan">
    <Name>Isilon Fan</Name>
    <Description>Fan</Description>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Class.IsilonCluster.PhysicalFan" SubElementID="Index">
    <Name>Index</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Relationship.NodesHostsPhysicalFan">
    <Name>Isilon Cluster Hosts PhysicalFan</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Discovery.PhysicalFan">
    <Name>Discover Isilon Cluster Physical Fans</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.DataSource.DiscoverPhysicalFan">
    <Name>Discover Isilon Cluster PhysicalFan</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.ClusterPhysicalFanAvailabilityDependency">
    <Name>Isilon Fan</Name>
    </DisplayString>
    <DisplayString ElementID="IsilonSNMP.Monitor.ClusterClusterAvailabilityDependency">
    <Name>Cluster</Name>
    </DisplayString>
    </DisplayStrings>
    </LanguagePack>
    </LanguagePacks>

  • SNMP monitoring of Oracle 10g?

    Hi there,
    I'm curious about using SNMP technology to monitor Oracle 10g databases.
    I've done some light reading on the subject and I'm now at the stage
    where I have a few questions.
    -What exactly do I need to configure in my Oracle 10g environment?
    -Is Enterprise Manager the best and/or only UI available for me
    to carry out configuration chores?
    -I see no SNMP specific documentation for 10g; why is that?
    -I do see a good document for 9i:
    Oracle SNMP Support Reference Guide Release 9.2.0 Part Number A96672-01
    http://download-west.oracle.com/docs/cd/B10501_01/em.920/a96672/toc.htm
    Is the above document suitable for configuring SNMP monitoring of Oracle
    in a 10g environment?
    -moi

    I'm able to set up traps via the EM website following these instructions:
    http://download-west.oracle.com/docs/cd/B19306_01/em.102/b40002/notification.htm
    However, what I'm really looking for is the ability to do snmp gets. I need functionality similar to how the old school DBSNMP under OMS used to work. These commands seem to be totally missing. I found the following documentation:
    http://download-east.oracle.com/docs/cd/B19306_01/em.102/b16244/chap2.htm#sthref74
    Which indicates there should be an snmp subfolder under $ORACLE_HOME/sysman, but that folder does not exist in my installation. I installed Oracle EE. Is there another package I need to install in order to make the subagent run like a normal snmp agent?
    So far if I do a:
    emctl start dbconsole
    that starts up the EM Website and I can use that no probelm. If I...
    emctl start agent -- I get:
    Starting agent ... started.
    issuing a 'emctl staus agent' gives me a normal status message. Things start to get strange when I try to start the subagent, which to my understanding is what I need running in order to to talk to net-snmp, which is the master agent running on this host. Here's what happens:
    [zaro@cheetah bin]$ ./emctl start subagent
    Oracle Enterprise Manager 10g Database Control Release 10.2.0.1.0
    Copyright (c) 1996, 2005 Oracle Corporation. All rights reserved.
    Starting sub agent .....started
    [zaro@cheetah bin]$ ./emctl status subagent
    Oracle Enterprise Manager 10g Database Control Release 10.2.0.1.0
    Copyright (c) 1996, 2005 Oracle Corporation. All rights reserved.
    Sub agent is not running..
    I guess my question is how do I get to have the ability I used to have back in 8i to start up dbsnmp and then have my SNMP monitoring app "discover" the agent and use its instrumentation to get data?

  • SolMan and SNMP traps?

    Hi experts,
    I'm searching some information about the possebilities with SolMan and SNMP traps.
    I know that it is possible to send SNMP traps from SolMan to e.g. an external monitoring tool, to send alert information (CCMS/RZ20) to this monitoring tool.
    But is it possibel to recieve SNMP traps in SolMan and e.g. create Service Desk tickets out of them?
    Thanks
    Thomas

    Thomas,
                 Can you please share your experience about sending SNMP traps to solution manager? I am trying to find information on how to configure Solution Manager for receiving the SNMP traps. Please guide me on this.
    Thanks
    DG

  • Is there anyway to monitor network traffic on the newer Time Capsules, similar to the SNMP monitoring previously?

    Is there anyway to monitor network traffic on the newer Time Capsules, similar to the SNMP monitoring previously?

    Can I use a real router and still have the Time Capsule for backups etc?
    Yes, that is what Bridge Mode is for.  Just connect the Time Capsule to a LAN <--> Ethernet port on your "main" router.

  • Prime\SNMP Monitoring of dynamic interfaces

    Hi - Is anyone aware of a method of monitoring the bandwidth utilisation on a dynamic interface on a WLC?
    I'd like to monitor the traffic on each dynamic interface to generate usage stats on centrally switched guest and employee SSID's.
    Thanks

    You have to get that stats from switch where you defined those SVI. WLC dynamic interface not terminate any L3 traffic  & switch SVI is the place to go.
    If you have netflow monitoring or simple snmp monitoring tool, you can get that stats from the switch.
    HTH
    Rasika
    **** Pls rate all useful responses ****

  • SNMP Monitor PIX throught VPN tunnel

    I have two Cisco PIX 515e firewalls configured in fail-over. The primary PIX has private address 192.168.1.5 and the secondary PIX (standby) has a private address 192.168.1.6. The PIX firewalls are running IOS 6.3.3. I'm connecting to the PIX firewalls through a VPN tunnel (PIXes terminate VPN tunnel) and my monitoring system uses SNMP to monitor devices behind the PIX firewalls and the primary PIX private IP address. I would also like to monitor the standby IP address 192.168.1.6 from the tunnel and have been unsuccessful thus far. I can do this from behind the PIX, but not through the tunnel (only the primary PIX).
    Is there a way I can SNMP monitor (and PING) the IP address of the standby PIX through the VPN tunnel?
    Please send email to [email protected]
    Thank you,
    frank

    Paul,
    Thank you for your email. Yes, we currently use this command to monitor the active private IP of the active PIX firewall through the VPN tunnel. What I would like to be able to monitor is the private IP address of the standby PIX firewall (has a different IP address while in standby mode) – would like to make sure that it too is up and running (I can do this today for other PIX firewalls from the inside, but not through the tunnel.
    Best regards,
    Frank Pikelner
    Hi Frank,
    Don’t think you are going to get that to work due to the routing issues. Sending syslog messages to the snmp server is the only way I’ve done it in the past. Have you given this a try?
    http://cisco.com/en/US/products/sw/secursw/ps2120/products_configuration_guide_chapter09186a008017278a.html#wp1052111
    http://cisco.com/en/US/products/sw/secursw/ps2120/products_system_message_guide09186a00800896ac.html
    I hope this is of some help.
    Cheers,
    Paul.

  • SCOM 2012 SP1 - Setup SNMP monitoring = ping OK, no response SNMP.

    Hello, 
    I've tried the snmp monitoring in lab domain, everthing work. Now I work in the production environment, but I can't  make work the snmp. I've tried only snmp, but the same error occure. The Ping is ok, all my firewalls rules allows snmp and ping over
    the domain. 
    But when I launche the discovery, I've got an error after "No Response SNMP". I've analized the network with wireshark, I see the snmp get send to scom to the network device, but the netowrk device, reply " Destionation unreachable (Port unreachable)".
    I've check with "netstat -ano -p udp" but I don't see the port 162, the 161 is open and snmp.exe service use it. But 162 is not open and Healthservice.exe doesn't use it.
    I tried to reboot the server, but nothing change. And I check all my configuration, and it's the same in my lab domain and te production.
    Anybody have the same issue? Or a workaround? 
    Thank you in advance.
    KimBaxZ

    Hello Roger, 
    1. Windows Firewall 
    a. SNMP service authorized 
    b. SNMP trap not authorized 
    c. PING.exe authorized 
    d. HealthService.exe authorized 
    2. SNMP service configuration 
    a. Security => Community name + Right OK
    b. Security => Accept SNMP packets from any host
    3. SNMP trap service disabled 
    4. The network device (cisco switch is already configured and the snmp work well)
    a. It's possible to execute a snmp walk on the switch, and we get all the data (we use a différents
    computer to do this, like a linux server on the same network) 
    5. We use snmp v2 on the switch, and during the discovery scom, send v2c snmp get to the switch with the good community name.
    6. I tried to forge a snmp v2 packet and send them to the scom server, wireshark see the packet
    During the discovery the switch get the snmp request, but he can't reply, the snmp trap port (162) on the scom server is not open. And I don't know why. 

  • NSS4000 and SNMP

    Hello,
    please how i can monitoring NSS via SNMP? Now i have latest version of firmware, and in menu i have only SNMP Traps
    but i looking for SNMP monitoring like Traffic, CPU load etc, in SNMP Traps i can download MIB file for monitoring but how i can set Community?
    regards,
    Tomas

    Sorry for the very late response, first of all.
    There is another post here asking the same basic question; how can you monitor (Install SNMP Agent) on the NSS?
    Unfortunately, we can't; at least I have not been able to find a way to do this. The main reason is part of your question; "How can you set the community?", there is no way to do that. All we can do is set the traps, and let our SNMP software catch them. As for looking directly at the CPU load, memory, etc. we..err; should say, I have not been able to do this in my lab. Packet captures do show the information flowing, and traps do work; the bummer part is that we really can't be very pro-active.
    I hope someone else sees this post and correct what I am saying.

  • Nagios SNMP Monitoring for NSS devices ?

    Has anyone managed to utilise the inbuilt SNMP functions of the NSS with nagios efficiently ?
    if so, what plugins are you using and how have you got them configured ?
    Steve

    There are some threads in this forum regarding this already. It is not as easy as monitoring a switch or router. the controllers combine the AP mac with the oid for unique lines. You can glean some snmp info off the controllers by using some of the generic OIDs and controller specific OIDs, but you will need an snmp monitoring program that you can load the WLC MIBs into and then tailor your monitoring of the controller based on that. I use Cacti, which is really awesome, but I would need to grab the complete OID off each controller based on the APs on it, which is fine as long as the AP is on that particular controller and not another one. snmpwalk is your friend in this case.
    OID+mac = results

  • SNMP Monitoring behind SCOM Gateway Server

    Hi All
    Is it possible to monitor Network devices / SNMP that sit behind a SCOM Gateway server? If so, how do these get discovered?
    I have a need to monitor devices like HP printers, WAP, JetDirect cards, EPOS equipment etc. on a site that doesn't have SCOM on-premise.
    Are there any limitations to this?
    Thanks

    Hi,
    Yes, it is possible. when you create discovery, you may specify that it should run from gateway server.
    On the device you want to monitor, set your SNMP public community string to point to the IP address of the SCOM Gateway server. In the SCOM Administration console, choose Network Devices in the Discovery Managment Wizard choose network device and click next.
    In the next screen enter the IP address of the network device you want to monitor and under the mangment server drop down choose the gateway server who’s IP you entered in the SNMP string earlier.
    Here is a similar thread for you reference:
    https://social.technet.microsoft.com/Forums/systemcenter/en-US/475cf4f5-c724-4c7c-808e-7265b304b0ba/snmp-monitoring-over-gatewayserver?forum=operationsmanagergeneral
    In addition, you may check is there any management pack for your devices and import them into your management group.
    Regards,
    Yan Li
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

Maybe you are looking for