Looping through visa resources

I have a PXI Chassis that contains 8 serial cards.  For simplicity sake, say they're wired 1-2, 3-4, 5-6, 7-8.  So, basically, what ever I write to 1, I want to read at 2 - the same with the others.  I have the code that configures the com ports and writes/reads the data to one set of ports.  What I want to do, however, is somehow put this is a loop so as to have the com port number (enum) increment.  The two questions I have are:
1) If looping this way is the best way to go, how do I increment from COM port 1 to COM port 3.
2) On the PC where I'm developing, I just have COM1 and LPT1 that show up in my VISA Resource control drop down.  On the target, however, I know we have about 16  COM ports.  I want to test specific ones though.  Do I need to create some type of array of valid COM ports.  Is this something that I have to hard code or can I do it dynamically.

You can use the for loop but you probably don't want to auto-index. Maybe if you got the array size and divided by 2 and wired this to the 'N' terminal. Inside the for loop, use the index array function to get elements 0 and 1 the first iteration, 2 and three the next, etc. A shift register will retain the index value.
Message Edited by Dennis Knutson on 07-27-2006 11:57 AM
Attachments:
for loop.JPG ‏9 KB

Similar Messages

  • How to loop through the "On My Mac" folders in mail?

    Hi there - i am new to applescript, but am slowly working out how to use it.
    I am stumped on how to write a rule that will move a message to a folder identified by a tag in a message (I am using MailTags).
    I have script that will take the first tag and move the message to a mail folder in a fixed location (e.g. Archive/<tag name>) however I wanted to make it more generic by looping over all of my mail folders and finding one that matched the tag name.
    However I am stumped on how to loop over all of my mail folder names - I have tried:
    repeat with aFolder in (every mailbox of (mailbox for "ON MY MAC"))
    and
    repeat with aFolder in every mailbox of inbox
    etc.
    but none of these seem to work.
    Is there some magic syntax to do this, so that I can do:
    if (name of aFolder = msgTag) then
    move oneMessage to mailbox (name of aFolder)
    end if
    Tim

    You don't necessarily need to assign a variable to the entire list in order to loop through them (unless you really want to) - for example:
    tell application "Mail" to repeat with aFolder in (get mailboxes)
            -- do stuff with aFolder
    end repeat
    There are several AppleScript resources, but the main ones I use are:
    AppleScript Language Guide
    AppleScript Tutorials at MacScripter.net

  • Question on how to loop through a variable amount of objects

    I have a csv file which I am parsing with powershell and it works perfectly. I would like to speed it up. Currently, I call a line that is customized for each groups list of subnets.
    I have about 30 groups.
    Some groups have one subnet, some have 5 subnets.
    I want to set up some sort of loop to parse everything while executing a single Import-CSV. Currently I call Import-CSV once per group. It takes me about 2-4 minutes to parse the entire file depending on the speed of the machine.
    The csv file has about 30,000 rows. I am not concerned about running out of resources. This is as much a learning challenge as a desire to make better powershell scripts.
    Below is a portion of the one liner that would parse the entire csv file looking only for those items that match, and writing them out to that groups specific csv file.
    Example #1
    Import-Csv $HostList |  Where-Object {$_."IP Address" -Match "^192.1.*" -or $_."IP Address" -Match "^192.2.*" -or $_."IP Address" `-Match "^192.3.*"  .....}| do more stuff...
    Example #2
    Import-Csv $HostList |  Where-Object {$_."IP Address" -Match "^192.7.*" ....}| do more stuff...
    The example above is just a snippet from code that works perfectly.
    The problem I am asking for help with is, when I loop through the items I am matching against (subnets), if one group has 3 items to match against, another has 1, another has 7, how do I set up such a loop?
    Am I using some sort of 'while'  $_."IP Address" or...?
    Do I create a big 30,000 array (Does PS even use arrays?)
    I would love to know what this type of looping is called, and what I can read with examples on how to understand approaching this challenge..
    Thank you for any help.
    -= Bruce D. Meyer

    The reason for the parsing (I thought I explained it, must have been too vague) is I have about 30 agencies in a csv file.
    Each agency can be determined by their subnet(s) and domain(s)
    I need to put all lines in the csv relating to each agency in their own separate csv file to distribute to them so I am not sharing agency 'A' info with the other 29 agencies.
    I get the regex comment. Thank you. For some reason I am rather hesitant to use PCRE under windows. I'll see how it works.
    Your comment on "Reloading a large file repeatedly takes more time", is the exact reason why I asked the question. I want to get away from that.
    I appreciate your quick reply, I think your example will work nicely. 
    -= Bruce

  • Working with VISA resources in Labview 6

    I am having difficulties programming through VISA in Labview 6.0.2. I have installed MAX 3.2, and have configured my two devices going through USB:
    1) an Agilent 82357A USBtoGPIB adapter connected with an Agilent 53131A Universal Counter
    2) a USBtoRS422 converter registered as serial COM4 connected with a Rainin Peristaltic pump
    I can open communication with both devices from within MAX, and send/receive data with no problem.
    When I try to program in Labview 6, I cannot communicate with either VISA device, even though I am using VISA instrument IO vi's with the configured VISA resource name from MAX. I'm not sure what I'm doing wrong.
    Is there an incompatability between MAX 3.2 and Labview 6.0.2, or have I configured something wrong?
    Thank you for the assistance.

    Hello,
    I think we can defeat the problem with Device 1 fairly quickly. If you have established that you can communicate with the device in MAX, I think we simply have a small programmatic change to make in LabVIEW. I am interested in having you attempt using the VI I have attached, which allows you to specify the bytes you would like to send in an array, and then simply sends the corresponding the string of ascii characters (the characters corresponding to the values in the array); this way we can be sure to send exactly what we would like. The following link has an ascii table in it, which you can use as a reference when putting the values into the array: (where the first byte specified will be the first character in the string)
    http://www.ni.com/pdf/manuals/371253a.pdf
    Simply change the VISA resource name to reflect your device and give it a try.
    As for Device 2, let's try using the same VI (attached) and write a command which the device is known to understand. A simply query would be approprite, where you can write using the attached VI, and then read using another VI which literally only has a VISA Read function in it (and a resource control or constant connected with your resource specified).
    One thing to verify before reposting is whether the devices you have use EOS (end of string) and/or EOI (end or identify) termination of GPIB operations. For EOS, a character is sought by the listener to indicate the end of a transmitted string, such as a linefeed or carriage return (or both). EOI termination is defined by the talker asserting the EOI line when the last byte to be transmitted is sent; the listener knows it has received the last byte of that transmission.
    Definitely repost; it is likely that we are only few programmatic changes and perhaps a spec check (for the devices) away from dependable communication
    Thank you,
    JLS
    Best,
    JLS
    Sixclear
    Attachments:
    WriteByteArray.vi ‏14 KB

  • How to loop through a KM Folder ?

    Hi ....can someone please let me know how  to loop through a KM Folder having many documents , files etc .
    Waiting for replies !!
    Regards
    Smita

    Hi Smita
    Here is the code:
    String rLocationtest = "/documents/Folder1";
    IResourceContext c = ResourceFactory.getInstance().getServiceContext("cmadmin_service");
    ICollection collection = (ICollection)ResourceFactory.getInstance().getResource(RID.getRID(rLocationtest),c);
    loopFolder(collection,c);
    public void loopFolder(ICollection collection, IResourceContext c){      
             try{
             IResourceList resList = collection.getChildren();
         IResourceListIterator resItr = resList.listIterator();
                 while(resItr.hasNext()){
              IResource restemp = resItr.next();
              if(restemp.isCollection() && LinkType.NONE.equals(restemp.getLinkType())){     
                             loopFolder((ICollection)restemp,c);
                                    //If the restemp is not a collection, it is a resource.
                                    //Do the resource related operations here.
         }// End of while
             }catch(Exception e){
                  e.printStackTrace();
        }//End of loopFolder
    Hope it helps
    Thanks
    Deepak

  • Method to verify VISA resource is ready for writing.

    Dear Forum, I have a piece of equipment which I am connecting to LabView via serial. The Instrument Assistant is of course totally useless and fails for inexplicable reasons, but everything works perfectly in hyperterminal.
    When I try to adapt the "Basic Serial Write and Read.vi" example to my application, the implementation is very straightforward. However, it fails to work despite working in hyperterminal. After a little bit of investigation, I have determined that the problem is that after "VISA Configure Serial Port" the port is not *actually* available for writing quite yet, most likely because this is a very old computer.
    By inserting a delay between the "VISA Configure Serial Port" and the "VISA Write" I am able to get the program to work as expected 100% of the time. However, this is a very bad solution because on an end user's computer (which may be far better than this one) such a long delay may be completely unnecessary and cause poor performance. Particularly because this piece of equipment has 8 analog inputs, 8 analog outputs, 4 Relays, 20 24VDC outputs, 8 DIOs, and 3 passthrough RS232 ports so it will be communicating a lot of data.
    Is there a function that I can use to *guarantee* that the COM port is actually ready for writing? If I could do this, then it might return almost immediately on a fast computer, while still allowing plenty of time for slower computers to finish opening the port. It may well be something happening on the windows driver side of the port open command.
    This is LabView 8.20 running on a Windows XP in VirtualBox on Linux host server. Please don't just tell me that I should not be using Virtualized Windows, I'm sure this problem happens for people with old hardware as well as that is the only significant difference in terms of serial API. The virtualized instance is just likely to be slower dealing with hardware than it would be otherwise.
    Solved!
    Go to Solution.

    neltnerb wrote:
    By inserting a delay between the "VISA Configure Serial Port" and the "VISA Write" I am able to get the program to work as expected 100% of the time. However, this is a very bad solution because on an end user's computer (which may be far better than this one) such a long delay may be completely unnecessary and cause poor performance. Particularly because this piece of equipment has 8 analog inputs, 8 analog outputs, 4 Relays, 20 24VDC outputs, 8 DIOs, and 3 passthrough RS232 ports so it will be communicating a lot of data.
    This shouldn't be an issue, you open Visa resource and configure it at the start of the program and leave it open until you close the program  when you close the resource. A 100ms delay should be sufficient and only happens once. If you open, configure and close the resource every loop you'll run into lots of strange behaviour.
    /Y
    LabVIEW 8.2 - 2014
    "Only dead fish swim downstream" - "My life for Kudos!" - "Dumb people repeat old mistakes - smart ones create new ones."
    G# - Free award winning reference based OOP for LV

  • Looping through folders and subfolders

    Hi,
    I'm about to create a script to check some tifs and jpgs for the right height and width, resolution and so on.
    I could get it to work if I see the files in the content panel (looping through the files by app.document.getSelection ...
    The script needs to check many files in different subfolders (all in one parent folder), so I don't like to use a collection to reveal all files of all subfolders first and then start the script.
    My plan is to choose the parent folder in the folder panel and the script should  loop through each file of each subfolder ...
    So maybe there's someone who knows a solution for this problem, it would be great!
    Thanks a lot,
    Sebastian.

    Wow,
    That was fast, I'll test it tommorow in the morning, thanks a lot so far!
    Hopefully I'll be able to get our scripts together...
    Thanks
    Sebastian
    Am 05.08.2012 um 20:13 schrieb Paul Riggott <[email protected]>:
    Re: looping through folders and subfolders
    created by Paul Riggott in Bridge Scripting - View the full discussion
    This should get you started...
    #target bridge  
    var folders =[];
    folders = FindAllFolders(Folder(app.document.presentationPath), folders);
    folders.unshift(Folder(app.document.presentationPath));
    for(var a in folders){
    var fileList = folders[a].getFiles(/\.(jpg|tif)$/i);
    for(var p in fileList){
    var thumb = new Thumbnail(fileList[p]);
    var height = thumb.core.quickMetadata.height;
    var width = thumb.core.quickMetadata.width;
    var Resolution = thumb.core.quickMetadata.xResolution;
    if(Resolution ==0) Resolution =72;
    //do your processing here
    //$.writeln(decodeURI(thumb.spec) + "," + height + "," + width + "," + Resolution);
    function FindAllFolders( srcFolderStr, destArray) {
    var fileFolderArray = Folder( srcFolderStr ).getFiles();
    for ( var i = 0; i < fileFolderArray.length; i++ ) {
      var fileFoldObj = fileFolderArray[i];
      if ( fileFoldObj instanceof File ) {  
      } else {
             destArray.push( Folder(fileFoldObj) );
      FindAllFolders( fileFoldObj.toString(), destArray );
    return destArray;
    Replies to this message go to everyone subscribed to this thread, not directly to the person who posted the message. To post a reply, either reply to this email or visit the message page: http://forums.adobe.com/message/4599891#4599891
    To unsubscribe from this thread, please visit the message page at http://forums.adobe.com/message/4599891#4599891. In the Actions box on the right, click the Stop Email Notifications link.
    Start a new discussion in Bridge Scripting by email or at Adobe Forums
    For more information about maintaining your forum email notifications please go to http://forums.adobe.com/message/2936746#2936746.

  • Nested Loops...looping through one month of data at a time year by year

    Hi all,
    I'm trying to create an insert statement that loops through a table that has 10 years of data (2001 to 2010) month by month to minimize impact on server and commits more frequently to avoid filling up the redo logs and rollback tablespaces. The table is large, has about 40 millions records per year. Lets say the structure of the table is the following:
    Customer_ID number(9),
    Order_Item_1 number(6),
    Order_Item_2 number(6),
    Order_Item_3 number(6),
    Order_date date
    The table is in flat format but I want to normalize it so that it looks like the following:
    Customer_ID Order_Seq Order_Item Order_date
    999999999 1 555555 01-jan-2001
    999999999 2 666666 01-jan-2001
    999999999 3 444444 01-jan-2001
    888888888 1 555555 03-jan-2001
    888888888 2 666666 03-jan-2001
    But because I want to loop through month by month....I need to set it up so that it loops through month by month, year by year (Using the Order Date Field) and Order_item by Order_item. Something like:
    so my insert statements would be something like if I hardcoded instead of put the insert statement into a loop:
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,1,Order_item,Order_date where Order_item_1 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='01';
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,2,Order_item,Order_date where Order_item_2 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='01';
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,3,Order_item,Order_date where Order_item_3 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='01';
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,1,Order_item,Order_date where Order_item_1 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='02';
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,2,Order_item,Order_date where Order_item_2 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='02';
    insert into orders_normalized
    (Customer_id,Order_seq,Order_item,Order_date) select customer_id,3,Order_item,Order_date where Order_item_3 is not null and to_char(order_date,'yyyy') = '2001' and to_char(order_date,'mm')='03';
    Hope this makes sense.
    Thanks

    Does the sequence of items in an order really matter? In other words, do we really need to preserve that an item was in position 2 versus position 1? I bet that the sequence or position of each item in an order is not meaningful. They were probably numbered 1, 2, and 3 just to make them uniquely named columns so there would be three slots to hold up to 3 items in the denormalized table.
    You only have about 400 million rows to insert, so it could feasibly be done in a single transaction (depending on your database environment).
    You can always do a create table as select (CTAS) to help with undo / redo issues and get better performance. You could run it in parallel, and spit it out to a new table partitioned by month. Single DDL statement running in parallel making your new table--sounds good to me.
    How about something like this:
    CREATE TABLE ORDERS_NORMALIZED
    (CUSTOMER_ID, ORDER_ITEM, ORDER_DATE)
    PARTITION BY RANGE(ORDER_DATE)
    PARTITION p200901 VALUES LESS THAN (TO_DATE('200902','YYYYMM')),
    PARTITION p200902 VALUES LESS THAN (TO_DATE('200903','YYYYMM')),
    PARTITION p201012 VALUES LESS THAN (TO_DATE('201101','YYYYMM'))
    as SELECT CUSTOMER_ID, ORDER_ITEM_1, ORDER_DATE
       FROM OTHER_TABLE
       WHERE ORDER_ITEM_1 IS NOT NULL
       UNION ALL
       SELECT CUSTOMER_ID, ORDER_ITEM_2, ORDER_DATE
       FROM OTHER_TABLE
       WHERE ORDER_ITEM_2 IS NOT NULL
       UNION ALL
       SELECT CUSTOMER_ID, ORDER_ITEM_3, ORDER_DATE
       FROM OTHER_TABLE
       WHERE ORDER_ITEM_3 IS NOT NULL.....................
    Out of curiosity, why not normalize it further? You could have used two tables instead of one.
    One (ORDER) with:
    ORDER_ID
    CUSTOMER_ID
    DATE
    Order_id would be a new surrogate key / primary key.
    Another table (ORDER_ITEM) with:
    ORDER_ID
    ORDER_ITEM
    It would be a table that links ORDERS to ITEMS. You get the idea.

  • Text is not being displayed in sync on a label when looping through a list -- how to fix?

    I have a list of states (50 states).  I loop through this list (in a winform app -- VS2012) and want to display the current state ID that is being processed in the loop in the text property of a label.  I precede the label.Text = StateID line with
    Application.DoEvents() but I am also (in Debug mode) writing the same text to the console.  The console displays correctly, but there appears to be a lag in the label.Text property
    List<string> StateList = new List<string> { "al", "ak", "az","ar","ca","co","ct","de","fl","ga",...};
    foreach (string stateID in StateList)
        Application.DoEvents();
        lblStateID.Text = "State is " + stateID;  //--there is a lag here
    I vaguely recollect something about a NotifyPropertyChanged event.  I know this is common in WPF, but is there something similar in winform?  Or is there a way to make the desired text to be displayed in the label.Text property in synchronization
    with the loop?
    Rich P

    Thank you.  This is way simpler than implementing the INotifyPropertyChanged Interface.  Although, here is an article on the INotifyPropertyChanged Interface and event
    http://msdn.microsoft.com/en-us/library/system.componentmodel.inotifypropertychanged(v=vs.110).aspx
    Rich P

  • Check for empty visa resource?

    When I am developing the VI at my desk and not a the test station PC, the VISA resource name is empty.
    Once the VI is moved to the test station PC, the user can select a VXI board.
    How do I make sure the user has selected a VISA resource before continuing?
    I can wire a Comparision to check for Empty String, and that works. But is there any method that I should use?
    Solved!
    Go to Solution.

    Additionally, you can limit the selectable items by interface type. Right-click VISA Resource Name Control and select I/O Name Filtering.
    National Instruments
    Product Support Engineer

  • Old visa open, error code 1073807343, using VISA with a GPIB device, and VISA resource names

    Hi everyone,
    I'm trying to get a SRS model SR720 LCR meter (manual on this page) working with LabView, connecting it to my PC with an Agilent 82357A GPIB/USB interface (manual on this page). I'm running MAX version 14.0, and NI-VISA version 14.0. I'm running LabView version 13.0f2, 32 bit.
    I followed the directions on this page, and I'm pretty confident I can communicate with my LCR meter, because I can go to NI MAX->GPIB0::17::INSTR under "devices and interfaces", then go to the VISA test panel, go to the I/O tab, and I can enter a few commands from the SR720 manual, like changing the frequency, and I see the light on the LCR meter change to what I just told it to do. Here is a picture, just to illustrate it:
    Also, if I do the *IDN? command, it returns "
    9: Write Operation (*IDN?)
    Return Count: 5 bytes
    10: Read Operation
    Return Count: 41 bytes
    StanfordResearchSystems,SR720,08087,1.03\n
     So, that's good too. I also made the alias of this device "MyLCRmeter", but that shouldn't matter for now.
    Now I'm trying to get it to work in a more usable way. The SR7xx drivers that LabView found for me came with a couple sample programs, one called "Getting Started.vi". I tried to just simply see if it worked, changing the "instrument descriptor" field to "GPIB0::17::INSTR", since that's the one that seemed to be the right device in MAX. Here is a picture of the front panel of "Getting Started.vi":
    Trying to run it like this gave me this error (code -1073807343):
    Old VISA Open in SR715/720 Initialize.vi->SR715/720 Getting Started.vi
    Doing a bit of searching on these forums, I found these few threads (1 2 3), which seem to tell me that, since this program was written, the way you open VISA has changed. In the 2nd of those links, one guy said:
    You just have to replace the Old VISA Open function with the VISA Open that is on the Instrument I/O>VISA>VISA Advanced palette. When you do that, the wire to the string that was used for the resource name will be broken. Delete the string and make the actual VISA Resource Name visible on the front panel. Wire the VISA Resource Name control to the connector pane where the string control was (upper left connection).
    So, I went into the sub-VI Initialize.vi, and did that. Here is a picture of what the front panel and block diagram of the sub-VI Initialize2.vi (I changed the name in case I screwed things up, but I'm pretty sure the new one is the one being called by Getting Started.vi) looked like before I changed anything (you can see the Old VISA Open):
    and here it is after replacing that with the regular VISA Open, deleting the instrument descriptor string and replacing it with a VISA resource, and connecting that to the VISA Open:
    However, as you can see in the image above, and it seems like someone else had this problem in the 2nd thread linked above, I don't see my device listed in the drop-down menu (even if I refresh), only "LPT1" (I don't even know what that is):
    No, I wasnt able to select the visa resource from the pull down menu. somehow it seems disabled or something.
     If I just enter the VISA resource name from MAX manually, GPIB0::17::INSTR, and save and try running that, I get the error(code -1073807346):
    VISA Open in SR715/720 Initialize2.vi->SR715/720 Getting Started.vi
    So I'm not sure where to go from there, or why it's not in the drop down menu to begin with. I'm sorry if I've missed something but I've searched about as far as I can go. If I had to guess, maybe one thing could be that in MAX, under Tools->NI-VISA->VISA Options->My System->Conflict manager, I have both Agilent VISA and NI VISA enabled; I know sometimes problems arise from conflicts between different software fighting over the same hardware. Is this okay, or do I need to change it?
    Thank you and please let me know if there is any other code/screenshots I could provide that could help!

    Hi, I did indeed enable NiVisaTulip.dll under MAX->Tools->NI-VISA->VISA Options->My system->Passports->List of passports. Sorry, I should have mentioned that explicitly.
    By install as primary, do you just mean as it is here, where it is selected as the "Preferred VISA"?
    Or somewhere else? I installed NI-VISA first I believe, and then the Agilent one, and during the installation of the Agilent one, I'm pretty sure I made it not the primary. Here's what I have in the Agilent (it's called Keysight now) Connection Expert software:
    I also have this under the "Keysight 488 options" tab:
    Should that be checked? I don't actually know the role of VISA vs 488 here...
    What could I try?
    Thank you!

  • Automator - Loop through a text file and process data through a 3rd party software

    Just stumbled on Automator the other day (I am a mac n00b) and would like to automate the processing of a text file, line-by-line, using a third party tool.  I would like Automator to loop through the text file one line at a time, copy the string and keep as a variable.  Next, place the variable data (copied string) into the text field of the 3rd party software for processing.  Once the processing is complete, I would like Automator to fetch the next line/string for processing.  I see items like "copy from clipboard" and  "variables" within the menu but I am not finding much documentation on how to utilizle this tool.  Just hear how potentially powerful it is. 
    The 3rd party software is not a brand name, just something made for me to process text.  I may have to use mouse clicks or tabs + [return] to navigate with Automator.  A term I heard on Bn Walldie's itunes video series was "scriptable software" for which I don't think this 3rd party app would be. 
    Kind regards,
    jw

    Good news and bad news...
    The good news is that it should be entirely possible to automate your workflow.
    The bad news is that it will be a nightmare to implement via Automator, if it's even possible.
    Automator is, essentially a pretty interface on top of AppleScript/Apple Events, and with the pretty interface comes a certain stranglehold on features. Knowing how to boil rice might make you a cook, but understanding flavor profiles and ingredient combinations can make you a chef, and it's the same with AppleScript and Automator. Automator's good at getting you from points A to B but if there are any bumps in the road (e.g. the application you're using isn't scriptable) then it falls apart.
    What I'm getting at is that your requirements are pretty simple to implement in AppleScript because you can get 'under the hood' and do exactly what you want, as opposed to Automator's restricted interface.
    The tricky part is that if no one else can see this app it's going to be hard to tell you what to do.
    I can give you the basics on reading a file and iterating through the lines of text in it, and I can show you how to 'type' text in any given application, but it may be up to you to put the pieces together.
    Here's one way of reading a file and working through each line of text:
    -- ask the user for a file:
    set theFile to (choose file)
    -- read the file contents:
    set theFileContents to (read file theFile)
    -- break out the lines/paragraphs of text:
    set theLines to paragraphs of theFileContents
    -- now iterate through those lines, one by one:
    repeat with eachLine in theLines
      -- code to perform for eachLine goes here
    end repeat
    Once you have a line of text (eachLine in the above example) you can 'type' that into another application via something like:
    tell application "AppName" to activate
    tell application "System Events"
              tell process "AppName"
      keystroke eachLine
              end tell
    end tell
    Here the AppleScript is activating the application and using System Events to emulate typing the contents of the eachLine variable into the process. Put this inside your repeat loop and you're almost there.

  • Forms 6i loop through datablock question

    I am writing a piece of code to loop through items with in a datablock to programmatically set the width between each field.
    I created my data block through the wizard, but then manually added some fields. I have them listed in the order I expect them to be navigated, which is the order I expect them to appear on the screen.
    When I am looping through the data block, I was assuming that next_item would go to the next navigable item, and it doesn't.
    For example, I have items received_today, worked_today, total_waiting, total_for_today, total_calls, total_priority.
    When the code loops through the data block, it actually loops in this order: received_today, worked_today, total_callbacks, total_priority, total_waiting, total_for_today.
    I even set the next navigation item property for each item, but that didn't help.
    My questions:
    1. Is there a way to control what order the data block loops through items?
    2. Why does this line get_item_property(get_block_property(block_name, FIRST_ITEM), x_pos); sometimes return null? (in my "proof of concept" form it returns a value, but the form I am modifying does not)
    Following is my code:
    PROCEDURE set_x_y_positions IS
         current_x_position pls_integer;
         current_y_position pls_integer;
      block_name varchar2(30) := 'BLOCK22';
      CurrentItem varchar2(30);
    BEGIN
      go_block(block_name);
      current_x_position := get_item_property(get_block_property(block_name, FIRST_ITEM), x_pos);
      current_y_position := get_item_property(get_block_property(block_name, FIRST_ITEM), y_pos);
          go_block(block_name);
      loop
           BEGIN
                if :system.cursor_item <> (block_name || '.' || get_block_property(block_name, FIRST_ITEM))
                     and get_item_property(:system.current_item, displayed) = 'TRUE' then            
                  SET_ITEM_PROPERTY(:system.current_item, x_pos, current_x_position + 38);
                  current_x_position := get_item_property(:system.current_item, x_pos);
                end if;
                if :system.cursor_item = 'BLOCK22.INTERNATIONAL' THEN--block_name || '.' || get_block_property(block_name, LAST_ITEM) then
                          exit;
                else
                     next_item;
                end if;
           END;
      end loop;
    END;I am using Forms 6i version 6.0.8.26.0
    Thank you!
    Katia

    I do have an exit, and yes it does run well.
         if :system.cursor_item = 'ATS_MON_REPORTING_QUEUES_VW.INTERNATIONAL' THEN--block_name || '.' || get_block_property(block_name, LAST_ITEM) then
                          exit;
                else
                     next_item;
                end if;That redundant go_block is there because I had some output going to a dummy field in another block, so I had to make sure it was navigating back to the block. But yes, in this code example, that go_block is redundant.
    Thank you, adding the
    current_x_position := get_item_property(block_name||'.'|| get_block_property(block_name, FIRST_ITEM), x_pos);
      current_y_position := get_item_property(block_name||'.'|| get_block_property(block_name, FIRST_ITEM), y_pos); worked perfectly.

  • How do I get the VISA resource drop down menu to be auto populated in my stand alone application (exe file)?

    Hi all,
    Here's a hopefully simple question.
    I am building an application (i.e. an exe file) from a simple program which use VISA to read and write to a RS-232 com port. When I run it before building the application everything works fine and the VISA resource control, which is a drop down menu, is automatically populated with available com ports. When I run the application on a computer without LabVIEW installed nothing appears in this window. I have made an installer which includes NI LabVIEW Rutime Engine 8.5, NI Measurement & Automation Explorer 4.3 and NI-DAQmx 8.6.1. Is there anything else I need to include? Any specific settings I need to do when I build the exe-file?
    I use LabVIEW 8.5.
    Thank you.
    Solved!
    Go to Solution.

    DAQmx is only for NI DAQ cards so I'm not sure why you installed that. The driver for VISA applications is NI-VISA (surprise!)
    Add the NI-VISA run-time to your installer.

  • How do I loop through tables, not columns in a table?

    Sorry if this is a long one. My problem is actually quite simple. I am trying to write either an ad hoc PL/SQL block or a stored procedure to loop 18 times (thru 18 tables) and perform a SQL query on those tables, returning 18 resultsets. I would like the results to show up on the screen (or in a spool file, whatever).
    So far I have tried 3 different approaches, none of which have worked.
    1. I tried to assign the select query to a variable (qry) and use EXECUTE IMMEDIATE qry. This forced me thru a variety of errors to declare variables and assign the result to them--EXECUTE IMMEDIATE qry into nm0, nm1, nm2...
    The problem with that was the resultset returned more than the variable was built for as there might be no rows returned, or it might be a thousand rows of data. So I tried changing the variables to VARRAYS, but it gave me a type mismatch as the underlying columns were NUMBER and VARCHAR2.
    DECLARE
         ctr number;
         TYPE NUMLIST IS VARRAY (1000) OF NUMBER;
         TYPE VARLIST IS VARRAY (1000) OF VARCHAR2(15);
         nm0 NUMLIST NOT NULL DEFAULT 1;
         nm1 VARLIST;
         nm2 NUMLIST NOT NULL DEFAULT 1;
         nm3 VARLIST;
         nm17 NUMLIST NOT NULL DEFAULT 1;
         qry VARCHAR2(2000) := 'klx_uln_p000_cells';
    BEGIN
    FOR ctr IN 1..17 LOOP
         IF ctr &lt; 10 THEN
              qry := 'SELECT
              A.DIM_0_INDEX,
              S0.SYM_NAME,
              A.DIM_1_INDEX,
              S1.SYM_NAME,
              A.DIM_2_INDEX,
              S2.SYM_NAME,
              A.DIM_3_INDEX,
              S3.SYM_NAME,
              A.NUMERIC_VALUE,
              B.NUMERIC_VALUE
              FROM
              KHALIX.klx_uln_p00'||ctr||'_cells A,
              KHALIX.klx_ucn_p00'||ctr||'_cells B,
              KHALIX.KLX_MASTER_SYMBOL S0,
              KHALIX.KLX_MASTER_SYMBOL S1,
              KHALIX.KLX_MASTER_SYMBOL S7
              WHERE
              A.DIM_0_INDEX=B.DIM_0_INDEX AND
              A.DIM_1_INDEX=B.DIM_1_INDEX AND...
              A.DIM_7_INDEX=S7.SYM_INDEX';
         ELSE
              qry := 'SELECT
              A.DIM_0_INDEX...
              A.DIM_7_INDEX=S7.SYM_INDEX';
         END IF;
         BEGIN
         dbms_output.put_line('SELECT FOR KLX_ULN_P00'||ctr||'_CELLS');
         dbms_output.put_line(nm16);
         dbms_output.put_line(nm17);
         EXECUTE IMMEDIATE qry into nm0,nm1,nm2,nm3,nm4,nm5,nm6,nm7,nm8,nm9,nm10,nm11,nm12,nm13,nm14,nm15,nm16,nm17;
    --     dbms_output.put_line(qry);
         dbms_output.put_line(nm16);
         dbms_output.put_line(nm17);
         EXCEPTION
              WHEN NO_DATA_FOUND THEN
                   dbms_output.put_line('No data found for Query '||ctr);
         END;
    END LOOP;
    EXCEPTION
         WHEN NO_DATA_FOUND THEN
              dbms_output.put_line('No data found for Query '||ctr);
    END;
    2. So then I used REF CURSOR to create a stored procedure and return the values. That allowed me to run my query AND tokenize the tablenames with a counter so that it would loop through the different tables! However, I still could not get it to display the results without going to SQL Plus and typing 'print c;'.
    3. So, finally I tried to create a looping wrapper around the ref cursor to have some variable (ctr) increment so my query would get performed on table0_cells through table17_cells. This, too, did not work.
    If I manually go to SQL Plus and type:
    variable ctr number
    begin
    :ctr := 1;
    end;
    exec dupe_find(1,:c);
    it will execute for the first table (klx_uln_p001_cells) and I can then type 'print c' to see what was returned. But when I try putting this within a wrapper PL/SQL block with a Loop to make ctr go from 0 - 17 (to loop through table_names klx_uln_p000_cells to klx_uln_p017_cells), it does not work.
    Help! It should be very simple to loop through tables, shouldn't it? I just want a script that will loop through tables, perform a query on each table and display the results. For some reason, I can only find documentation examples on looping through columns that are all in the same table.
    Dave

    Here's a working example using your first strategy ...
    create table t1 (id number);
    create table t2 (id number);
    insert into t1 values (100);
    insert into t1 values (101);
    insert into t2 values (200);
    insert into t2 values (201);
    declare
    v_table_name user_tables.table_name%type;
    type ttab_id is table of t1.id%type index by binary_integer;
    tab_id ttab_id;
    begin
    for i in 1 .. 2 loop
    v_table_name := 't' || i;
    execute immediate 'select id from ' || v_table_name
    bulk collect into tab_id;
    dbms_output.put_line('query from ' || v_table_name);
    for j in 1 .. tab_id.count loop
    dbms_output.put_line(tab_id(j));
    end loop;
    end loop;
    end;
    There are many other ways to do this (especially if you need to do more than just print out the data).
    Richard