Remove Maximize button from popup window using Webdynpro ABAP
Hi,
Is there a way to remove the maximize button from a popup window using Webdynpro ABAP?
Thanks,
Jay
Hi Jayanth,
I think by setting is_resizable parameter pass abap_false. try this
lo_window = lo_window_manager->create_window(
window_name = 'POPUP'
title = 'Window'
close_in_any_case = abap_true
message_display_mode = if_wd_window=>co_msg_display_mode_selected
message_type = if_wd_window=>co_msg_type_none
is_resizable = ABAP_FALSE ).
Cheers,
Kris.
Similar Messages
-
How i can dissable/remove close buttons from popup window
We have an web application so i want to dissable/remove the close button , so please help me as soon as possible.
we are using only firefox for our web application and also for private use.
Thank you.Just to be sure, you want to '''Remove''' the close button?
I called the big guys for you. -
Removing title bar from popup window
Hi ,
I have created an popup window and I have to remove the title bar of that window completely(either to make the title bar invisible or to remove the title bar completely).
I have tried the following method but of no use,
1)window.removewwindowfeature.
Please provide solutions.
Thanks,
MaheshHi Mahesh,
Just try this out, it will resolve your issue.
[WebDynpro Popup Window|https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/a04870c5-749b-2b10-06ba-d25515ef39e3]
Regards, -
How to Remove Maximize button from JFrame
Dear all,
I am having problem with JFrame, that i need JFrame with Minimize and Close Button but not Maximize button.
I have already disabled the maximized button but I want to remove it from the JFrame.
Please show me the path to achieve this goal..it's relatively easy when java controls the decorations, using
JFrame.setDefaultLookAndFeelDecorated(true);
but this is generally not the L&F preferred.
run a program with the above line (line must be before any JFrame is created),
and if suitable, search the forum, solution has been posted a number of times -
Close Popup window in webdynpro abap.
Hi,
Can anyone tell me ...how to close the popup window through the action in webdynpro abap . In my popup window there is a button(i.e 'UPDATE') apart from that default 'OK' button , I want that when 'UPDATE' button is pressed, along with the action window should be closed. I dont want to close the window by pressing 'OK' button at the botton
I have used following code to open the popup window.
data lo_window_manager type ref to if_wd_window_manager.
data lo_api_component type ref to if_wd_component.
data lo_window type ref to if_wd_window.
lo_api_component = wd_comp_controller->wd_get_api( ).
lo_window_manager = lo_api_component->get_window_manager( ).
lo_window = lo_window_manager->create_window(
window_name = 'POP_UP WINDOW'
title = ''
close_in_any_case = abap_true
message_display_mode = if_wd_window=>co_msg_display_mode_selected
close_button = abap_true
button_kind = if_wd_window=>co_buttons_ok
message_type = if_wd_window=>co_msg_type_none
default_button = if_wd_window=>co_button_ok
lo_window->open( ).Hi Dear,
please try this code,
DATA lv_wc TYPE REF TO IF_WD_WINDOW_CONTROLLER.
data lv_view TYPE REF TO IF_WD_VIEW_CONTROLLER.
data lo_window type ref to if_wd_window.
lv_view = wd_this->wd_get_api( ).
lv_wc = lv_view->GET_EMBEDDING_WINDOW_CTLR( ).
lo_window = lv_wc ->GET_WINDOW( ).
lo_window->CLOSE( ).
Message was edited by: kumar.k kulanthaivel
Regards,
K. Karthikeyan -
Search Help from SAP values using WebDynpro ABAP in ADOBE Interactive Form
Hi,
How to populate search help on ADOBE interactive online form which is residing on a WebDynpro ABAP application?
Thanks & Regards,
Sandip amarHI,
Adobe from is integraated with R/3 just like smartform.
So if u use any DDIC tabel field which have inbuilt search help then it will automatically intergrated with Adobe form.
If not then u have to make at ztable via foreign key or via FM at program level.
Regards
ricky -
How to get the values from popup window to mainwindow
HI all,
I want to get the details from popup window.
i have three input fields and one search button in my main window. when i click search button it should display popup window.whenever i click on selected row of the popup window table ,values should be visible in my main window input fields.(normal tables)
now i am able to display popup window with values.How to get the values from popup window now.
I can anybody explain me clearly.
Thanks&Regards
kranthiHi Kranthi,
Every webdynpro component has a global controller called the component controller which is visible to all other controllers within the component.So whenever you want to share some data in between 2 different views you can just make it a point to use the component controller's context for the same. For your requirement (within your popups view context) you will have have to copy the component controllers context to your view. You then will have to (programmatically) fill this context with your desired data in this popup view. You can then be able to read this context from whichever view you want. I hope that this would have made it clear for you. Am also giving you an [example|http://****************/Tutorials/WebDynproABAP/Modalbox/page1.htm] which you can go through which would give you a perfect understanding of all this. In this example the user has an input field in the main view. The user enters a customer number & presses on a pushbutton. The corresponding sales orders are then displayed in a popup window for the user. The user can then select any sales order & press on a button in the popup. These values would then get copied to the table in the main view.
Regards,
Uday -
How to call parent view event or method from popup in java webdynpro
Hi ,
I have view in my webdynpro component. I created a button, when i click i am opening a popup window.
In side popup window i am doing some search criteria. I want call a parent view method from popup window and populate search results in parent view table control.I can able to pass the data through context mapping. But i want a custom method where i want to write a code to populate the table control ( i don;t want to use the wdDoModifyView() method).
Please help me.
Thanks
AravindaHi,
The methods in a view are only accessible inside same view. you cannot call it outside the view or
in any other view although its in same component.
If you want to have a method in both views, then create the method in component controller and
from there you can access the method any where in whole component. -
Remove EDIT button from FPM ToolBar
Hi All,
I am new to FPM, and I am working on SRM 7.0. In the Monitor Shopping cart WD application, after search event, a list of Shopping Carts are displayed, when we click on one of the SC number, the SC screen opens as a new Pop-up.
Here we have an EDIT button, and we need to remove this button from this screen.
Technical Details(EDIT button):
Application: /SAPSRM/WDA_L_FPM_OIF
Web Dynpro Component: FPM_OIF_COMPONENT
Window Information: FPM_WINDOW
View Information: CNR_VIEW
Configuration ID: ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL
Technical Details(SC screen):
Application: /SAPSRM/WDA_L_FPM_OIF
Web Dynpro Component: /SAPSRM/WDC_UI_SC_DOFC_HD
Window Information: IV_L_FPC_CA_HDR
View Information: V_SC_BOFC_HD
Configuration ID: /SAPSRM/WDCC_FPM_SC_HD_PR
Appreciate any help on this.
Thanks,
PrabhakaranHi Prabhakaran
You will need remove the static usage of config id ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL and make use of dynamic component configuration depending on the particular scenario.
Create two configuration id's ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL1 and ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL2. Set visible property of Edit button as visible in the first config ID and none in the second.
Now assign this config ID dynamically depending on the scenario. If scenario is Monitor SC, then assign config ID ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL2, else assign config ID ZSAPSRM_WDCC_FPM_OIF_SC_PROFNL1.
Please refer the below document for usage of dynamic component configuration.
http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/70337875-167f-2e10-daa7-a1c69d55ee95
Hope this helps.
Regards
Lorraine -
How to delete the items in the recycle bin permanently from the windows using Diruse command
How to delete the items in the recycle bin permanently from the windows using Diruse command.
Because most of the time we get out of disk space issues.
Can somebody help me in giving with an exampleYou can right-click Recycle Bin|Properties and choose radio button for
Don't move files ....
This one may also help.
http://technet.microsoft.com/en-us/library/cc784980(v=ws.10).aspx
Regards, Dave Patrick ....
Microsoft Certified Professional
Microsoft MVP [Windows]
Disclaimer: This posting is provided "AS IS" with no warranties or guarantees , and confers no rights. -
How to pass field value from popup window to oninput processing of other pg
Hi,
I want to pass a field value from the popup window to oninput processing of main page ( from where popup window is triggered). and need to close the popup window. How to do it ?
In the popup window's oninputprocessing, im doing some validation checks. If it passes all the validations, then only the control shd come to main page ..else it should stay in popup window only .
Regards,
Jothi.Hi Jothi,
you can use java script to pass the value and close your popup window. use the following code.
in your popup window:
function passData(h1)
window.opener.document.getElementById('var1').value = h1 ;
window.close();
then call this function when you finish your validations.
in your main page layout create an input field with id as passed in the function above "var1".
In the value attribute give it your variable as follow:
<htmlb:inputField id = "var1"
value = "<%= var2 %>"
visible = "false" />
"var2" will be assigned the value from your popup window.
I hope this will help you..
Regards,
Husain -
Hi,
I have a ribbon (done using ribbon XML) with menu options. I need to remove few buttons from the menu dynamically based on some condition. Also, I want to change the label of another button. How to achieve this programmatically? (C#)
Thanks in advance.
Thanks PrasadHello Prasad,
Use callbacks for populating Ribbon controls such as menu, dropDown, gallery and etc. Then you can use the
Invalidate or
InvalidateControl methods of the
IRibbonUI interface to get your callbacks invoked when required. Thus, you will be able to delete the required item(s).
You will find the following articles in MSDN helpful:
Chapter 11: Creating Dynamic Ribbon Customizations (1 of 2)
Chapter 11: Creating Dynamic Ribbon Customizations (2 of 2)
To change the label of your controls at runtime you need to use the getLabel callback and call the Invalidate or InvalidateControl methods of the IRibbonUI interface. The following series of articles describe the Fluent UI in depth:
Customizing the 2007 Office Fluent Ribbon for Developers (Part 1 of 3)
Customizing the 2007 Office Fluent Ribbon for Developers (Part 2 of 3)
Customizing the 2007 Office Fluent Ribbon for Developers (Part 3 of 3) -
Remove play button from inserted SWF
I'm using Acrobat 9 Pro. When inserting an animated SWF, it usually has a triangular play button. Is there a way to remove that button?
You can use "Create poster from file" under the Advanced options, and use a screenshot of the SWF. The play button graphic won't be added.
-
How To Remove Extended Partition From My Windows 8.1
When I am installing 8.1 in my pc but that time create extended partition but I don't want them and I want to remove them but when I remove them that time Error occurred & it's size is 128.45 GB and I can not remove them so please help me for
remove that partition from my windows pc.Hello jimeshcool007,
Do you mean that you have successfully installed the Windows 8.1 and you want to remove an extended partition?
What error occur when you try to remove the extended partition?
Please use the shortcut Windows + X and then open the
Disk Management.
Refer to the following screenshot to delete the extended partition.
Best regards,
Fangzhou CHEN
Fangzhou CHEN
TechNet Community Support -
Remove "execute" button from toolbar
Hi, colleagues! Is there any way to remove "execute" button from toolbar on selection screen (in custom report)? I only found how to append custom buttons (using function keys).
Thanks.Use EXCLUDING options of the SET PF-STATUS statement and insert the function code of the execute button into a internal table and pass it with EXCLUDING.
See F1 help on EXCLUDING.
Regards
Karthik D
Maybe you are looking for
-
I transferred some photos to my iphone via email and they have very low resolution. First I sent them from iPhoto with highest resolution, then I transferred them to my desktop in highest resolution and added them to an email, opened the email and s
-
Is there a way to upgrade a mid 2009 13" Macbook Pro so that it can use a wireless n network?
I have a mid 2009 13" macbook pro, and I live in a share house. The router we are using is very far away from my room and I do not get very good signal strength. However, my phone and ipad, which are newer, and have wireless n capability, are able to
-
How do I reformat my Seagate Expansion external hard drive so I can use it for Mac
I recently purchased a 3TB Seagate® Expansion® external hard drive for PC. My plan is too reformat it so that I can use it, but it has been acting wierd on me. It says on Disk Utility that it is 4 gbs but I have a 3TB one. Im on OSX mavericks by the
-
Hello Experts I am using a Chart web-item in a WAD web template. Now I have set up the value axis and the sample data property of the chart with a minimum value = -500 and max value = 3000. However, when I execute the web template on the portal the v
-
Report to get how many machines a user id has used
Hi Anyone could share to find machines logged on to from SCCM. Regards Sushain KApoor